×

A 2-D continuum model of a mixture of bone tissue and bio-resorbable material for simulating mass density redistribution under load slowly variable in time. (English) Zbl 1303.74029

Summary: The bio-mechanical phenomena occurring in bones grafted with the inclusion of artificial materials demand the formulation of mathematical models which are refined enough to describe their not trivial behavior. A 3D theoretical model, previously developed and used in 1D space, is employed to investigate and explain possible effects resulting from 2D interactions, which may not be present in 1D case so more realistic situations are approached and discussed. The enhanced model was used to numerically analyze the physiological balance between the processes of bone apposition and resorption and material resorption in a bone sample under plain stress state. The specimen was constituted by a portion of bone living tissue and one of bio-resorbable material and was acted by an in-plane loading condition. The signal intensity between sensor cells and actor cells was assumed to decrease exponentially with their distance; the effects of adopting two different laws, namely an absolute and a quadratic functions, were compared. Ranges of load magnitudes were identified within which physiological states are established. A parametric analysis was carried out to evaluate the sensitivity of the model to changes of some critical quantities within physiological ranges, namely resorption rate of bio-material, load level and homeostatic strain. In particular the spatial distribution of mass densities of bone tissue and of resorbable bio-material and their time evolution were considered in order to analyze the biological effects due to the parameter’s changes. Synthetically, these biological effects can be associated to different ratios between bone and bio-material densities at the end of the process and to different delays in the bone growth and material resorption. These numerical analyses allowed for finding the most desirable situations in which a gradual resorption of the artificial graft occurs together with the simultaneous formation of new bone, finally leading to an almost complete substitution of the bio-resorbable material with living tissue.

MSC:

74L15 Biomechanical solid mechanics
92C10 Biomechanics
Full Text: DOI

References:

[1] U.Andreaus and M.Colloca, Prediction of micromotion initiation of an implanted femur under physiological loads and constraints using the finite element method, Procs. of the Inst. of Mechanical Engineers. Part H, J. Eng. Med.223(5), 589-605 (2009).
[2] U.Andreaus, M.Colloca, and D.Iacoviello, Modelling of Trabecular Architecture as Result of an Optimal Control Procedure, Chapter II. In: Biomedical Imaging and Computational Modeling in Biomechanics, edited by U. Andreaus and D. Iacoviello (Springer, Berlin, Heidelberg, 2012), pp. 19-37.
[3] U.Andreaus, M.Colloca, and D.Iacoviello, An optimal control procedure for bone adaptation under mechanical stimulus, Control Eng. Pract.20, 575-583 (2012).
[4] U.Andreaus, M.Colloca, D.Iacoviello, and M.Pignataro, Optimal‐tuning pid control of adaptive materials for structural efficiency, Struct. Multidiscip. Optim.43(1), 43-59 (2011).
[5] U.Andreaus, M.Colloca, and A.Toscano, Mechanical behaviour of a prosthesized human femur: a comparative analysis between walking and stair climbing by using the finite element method, Biophys. Bioeng. Lett.1(3), 1-15 (2008).
[6] U.Andreaus, F.dell’Isola, and M.Porfiri, Piezoelectric passive distributed controllers for beam flexural vibrations, J. Vib. Control10(5), 625-659 (2004). · Zbl 1078.74026
[7] D.T.J.Barone, J.M.Raquez, and P.Dubois, Bone‐guided regeneration: from inert biomaterials to bioactive polymer (nano)composites, Polym. Adv. Technol.22, 463-475 (2011).
[8] M.Berry, Development of bioresorbable composite materials for orthopaedic devices, EMDT Eur. Med. Device Technol. (2008).
[9] A.S.Brydone, D.Meek, and S.Maclaine, Bone grafting, orthopaedic biomaterials, and the clinical need for bone engineering, Proc. IMechE, Part H: J. Eng. Med.224, 1329-1343 (2010).
[10] W.Ching, P.Rulis, and A.Misra, Ab initio elastic properties and tensile strength of crystalline hydroxyapatite, Acta Biomater.5(8), 3067-3075 (2009).
[11] S.Cowin, Bone Mechanics Handbook (CRC Press, Boca Raton, 2001).
[12] F.dell’Isola and R.Batra, Saint‐Venant’s problem for porous linear elastic materials, J. Elast.47(1), 73-81 (1997). · Zbl 0891.73011
[13] F.dell’Isola, M.Guarascio, and K.Hutter, A variational approach for the deformation of a saturated porous solid. A secondgradient theory extending Terzaghi’s effective stress principle, Arch. Appl. Mech.70(5), 323-337 (2000). · Zbl 0981.74016
[14] F.dell’Isola and S.Vidoli, Continuum modelling of piezoelectromechanical truss beams: An application to vibration damping, Arch. Appl. Mech.68(1), 1-19 (1998). · Zbl 0908.73067
[15] F.dell’Isola and S.Vidoli, Damping of bending waves in truss beams by electrical transmission lines with PZT actuators, Arch. Appl. Mech.68(9), 626-636 (1998). · Zbl 0920.73111
[16] V.A.Eremeyev and L.P.Lebedev, Existence of weak solutions in elasticity, Math. Mech. Solid.18(2), 204-217 (2012). · Zbl 07280041
[17] D.Farrar, Bioresorbable polymers in orthopaedics, business briefing: Medical device manufactoring & technology, Smith & Nephew, www.touchbriefings.com (2005).
[18] I.Giorgio, A.Culla, and D.D.Vescovo, Multimode vibration control using several piezoelectric transducers shunted with a multiterminal network, Arch. Appl. Mech.79, 859-879 (2009). · Zbl 1176.74128
[19] P.A.Gunatillake and R.Adhikari, Biodegradable synthetic polymers for tissue engineering, Eur. Cells Mater.5, 1-16 (2003).
[20] X.Han and J.Pan, A model for simultaneous degradation and crystallisation in biodegradable polymers, Biomaterials30, 423-430 (2009).
[21] R.Huang, J.Pan, A.R.Boccaccini, and Q.Chen, A two scale model for simultaneous sintering and crystallization of glass‐ceramic scaffolds for tissue engineering, Acta Biomater.4, 1095-1103 (2008).
[22] R.Huiskes, H.Weinans, H.J.Grootenboer, M.Dalstra, B.Fudala, and T.J.Slooff, Adaptive bone‐remodeling theory applied to prosthetic‐design analysis, J Biomech.20(11-12), 1135-50 (1987).
[23] C.C.Humber, G.K.B.Sándor, J.M.Davis, S.A.F.Peel, B.M.B.Brkovic, Y.D.Kim, H.I.Holmes, and C.M.L.Clokie, Bone healing with an in situ‐formed bioresorbable polyethylene glycol hydrogel membrane in rabbit calvarial defects, Oral and Maxillofacial Implants109(3), 372-384 (2010).
[24] S.J.Jones, A.Boyde, and N.N.Ali, The resorption of biological and non‐biological substrates by cultured avian and mammalian osteoclasts, Anat. Embryol. (Berlin)170, 247-256 (1984).
[25] A.R.Santos Jr., Bioresorbable polymers for tissue engineering, Tissue Engineering, edited by D. Eberli, ISBN: 978‐953‐307‐079‐7, InTech, Available from: http://www.intechopen.com/books/tissue‐engineering/bioresorbable‐polymers‐for‐tissue‐engineering, pp. 225-246 (2010).
[26] R.E.Jung, V.Kokovic, M.Jurisic, D.Yaman, K.Subramani, and F.E.Weber, Guided bone regeneration with a synthetic biodegradable membrane: a comparative study in dogs, Clin. Oral Impl. Res.22, 802-807 (2011).
[27] K.Kanayama, W.Sriarj, H.Shimokawa, K.Ohya, Y.Doi, and T.Shibutani, Osteoclast and osteoblast activities on carbonate apatite plates in cell cultures, Biomater. Appl.26, 435-449 (2011).
[28] J.Klein‐Nulend, P.J.Nijweide, and E.H.Burger, Osteocyte and bone structure, Curr. Osteoporosis Reports1, 5-10 (2003).
[29] J.Klein‐Nulend, A.Van der Plas, C.M.Semeins, N.E.Ajubi, J.A.Frangos, P.J.Nijweide, and E.H.Burger, Sensitivity of osteocytes to biomechanical stress in vitro, The FASEB Journal26, 441-445 (1995).
[30] G.M.Kontakis, J.E.Pagkalos, T.I.Tosounidis, J.Melissas, and P.Katonis, Bioabsorbable materials in orthopaedics, Acta Orthop. Belg.73, 159-169 (2007).
[31] T.Lekszycki, Modelling of bone adaptation based on an optimal response hypothesis, Meccanica37, 343-354 (2002). · Zbl 1141.74345
[32] T.Lekszycki and F.dell’Isola, A mixture model with evolving mass densities for describing synthesis and resorption phenomena in bones reconstructed with bio‐resorbable materials, Z. Angew. Math. Mech.92(6), 426-444 (2012). · Zbl 1241.92010
[33] L.H.Li, K.P.Kommareddy, C.Pilz, C.R.Zhou, P.Fratzl, and I.Manjubala, In vitro bioactivity of bioresorbable porous polymeric scaffolds incorporating hydroxyapatite microspheres, Acta Biomater.6, 2525-2531 (2010).
[34] A.Madeo, I.Djeran‐Maigre, G.Rosi, and C.Silvani, The effect of fluid streams in porous media on acoustic compression wave propagation, transmission, and reflection, Contin. Mech. Thermodyn. (2012), DOI:10.1007/s00161‐012‐0236‐y. · Zbl 1343.76068
[35] A.Madeo, D.George, T.Lekszycki, M.Nierenberger, and Y.Rémond, A second gradient continuum model accounting for some effects of micro‐structure on reconstructed bone remodeling, C.R. Mécanique340(8), 575-589 (2012).
[36] A.Madeo, T.Lekszycki, and F.dell’Isola, A continuum model for the bio‐mechanical interactions between living tissue and bio‐resorbable graft after bone reconstructive surgery, C.R. Mécanique339(10), 625-640 (2011).
[37] O.Marangos, A.Misra, P.Spencer, B.Bohaty, and J.Katz, Physico‐mechanical properties determination using microscale homotopic measurements: application to sound and caries‐affected primary tooth dentin, Acta Biomater.5(4), 1338-1348 (2009).
[38] C.Maurini, F.dell’Isola, and D.Del Vescovo, Comparison of piezoelectronic networks acting as distributed vibration absorbers, Mech. Syst. Signal Processing18(5), 1243-1271 (2004).
[39] C.Maurini, J.Pouget, and F.dell’Isola, On a model of layered piezoelectric beams including transverse stress effect, Int. J. Solids Struct.41(16‐17), 4473-4502 (2004). · Zbl 1079.74569
[40] C.Maurini, J.Pouget, and F.dell’Isola, Extension of the Euler‐Bernoulli model of piezoelectric laminates to include 3D effects via a mixed approach, Comput. Struct.84(22‐23), 1438-1458 (2006).
[41] A.Misra, O.Marangos, R.Parthasarathy, and P.Spencer, Micro‐scale Analysis of Compositional and Mechanical Properties of Dentin Using Homotopic Measurements, in: Biomedical Imaging and Computational Modeling in Biomechanics, edited by U. Andreaus and D. Iacoviello, Lecture Notes in Computational Vision and Biomechanics Vol. 4 (Springer Netherlands, Amsterdam, 2013), pp. 131-141.
[42] M.Mullender, A.J.ElHaj, Y.Yang, M.A.van Duin, E.H.Burger, and J.Klein‐Nulend, Mechanotransduction of bone cells in vitro: mechanobiology of bone tissue, Med. Biol. Eng. Comput.42, 14-21 (2004).
[43] S.Narang and V.Chava, Biomaterials used as bone graft substitutes, Annal Dent. Univ. Malaya7, 36-42 (2000).
[44] P.Nygaard‐Østby, V.Bakke, O.Nesdal, C.Susin, and M.E.U.Wikesjö, Periodontal healing following reconstructive surgery: effect of guided tissue regeneration using a bioresorbable barrier device when combined with autogenous bone grafting. A randomized‐controlled trial 10‐year follow‐up, J. Clin. Periodontol.37, 366-373 (2010).
[45] J.Pan, H.X., W.Niu, and R.Cameron, A model for biodegradation of composite materials made of polyesters and tricalcium phosphates, Biomaterials32, 2248-2255 (2011).
[46] R.Parthasarathy, A.Misra, J.G.Park, Q.Ye, and P.Spencer, Diffusion coefficients of water and leachables in methacrylate‐based crosslinked polymers using absorption experiments, J. Mater. Sci. Mater. Med.23(5), 1157-1172 (2012).
[47] S.Quiligotti, G.A.Maugin, and F.dell’Isola, An eshelbian approach to the nonlinear mechanics of constrained solid‐fluid mixtures, Acta Mechanica160(1-2), 45-60 (2003). · Zbl 1064.74061
[48] G.Rosi, I.Giorgio, and V.A.Eremeyev, Propagation of linear compression waves through plane interfacial layers and mass adsorption in second gradient fluids, Z. Angew. Math. Mech., pp. 1-14 (2013), DOI: 10.1002/zamm.201200285.
[49] G.Rosi, R.Paccapeli, F.Ollivier, and J.Pouget, Optimization of piezoelectric patches positioning for passive sound radiation control of plates, J. Vib. Control (2012), DOI: 10.1177/1077546312437236.
[50] G.Rosi, J.Pouget, and F.dell’Isola, Control of sound radiation and transmission by a piezoelectric plate with an optimized resistive electrode, Eur. J. Mech. A, Solids29(5), 859-870 (2010). · Zbl 1481.74564
[51] C.T.Rubin and L.E.Lanyon, Osteoregulatory nature of mechanical stimuli: Function as a determinant for adaptive remodeling in bone, J. Orthop. Res.5, 300-310 (1987).
[52] R.Ruimerman, P.Hilbers, B.van Rietbergen, and R.Huiskes, A theoretical framework for strain‐related trabecular bone maintenance and adaptation, J. Biomechanics38, 931-941 (2005).
[53] G.Sciarra, F.dell’Isola, and K.Hutter, A solid‐fluid mixture model allowing for solid dilatation under external pressure, Contin. Mech. Thermodyn.13(5), 287-306 (2001). · Zbl 1134.74365
[54] Y.Shikinami, Y.Matsusue, and T.Nakamura, The complete process of bioresorption and bone replacement using devices made of forged composites of raw hydroxyapatite particles/poly l‐lactide (F‐u‐HA/PLLA), Biomaterials26(27), 5542-51 (2005).
[55] J.A.Simon, J.L.Ricci, and P.E.Di Cesare, Bioresorbable fracture fixation in orthopedics: a comprehensive review. Part I. Basic science and preclinical studies, Am. J. Orthop. (Belle Mead NJ)26(10), 665-71 (1997).
[56] J.A.Simon, J.L.Ricci, and P.E.Di Cesare, Bioresorbable fracture fixation in orthopedics: a comprehensive review. Part II. Clinical studies, Am. J. Orthop. (Belle Mead NJ)26(11), 754-62 (1997).
[57] H.Tsuji, Autocatalytic hydrolysis of amorphous­made polylactides: Effects of L‐lactide content, tacticity, and enantiomeric polymer blending, Polymers43, 1789-1796 (2002).
[58] M.L.Wang, J.Massie, A.Perry, S.R.Garfin, and C.W.Kim, A rat osteoporotic spine model for the evaluation, of bioresorbable bone cements, The Spine Journal7, 466-474 (2007).
[59] Y.Wang, X.Han, J.Pan, and C.Sinka, An entropy spring model for Young’s modulus change of biodegradable polymers during biodegradation, J. Mech. Behav. Biomed. Mater.3, 14-21 (2010).
[60] Y.Wang, J.Pan, X.Han, C.Sinka, and L.Ding, A phenomenological model for the degradation of biodegradable polymers, Biomaterials29, 3393-3401 (2008).
This reference list is based on information provided by the publisher or from digital mathematics libraries. Its items are heuristically matched to zbMATH identifiers and may contain data conversion errors. In some cases that data have been complemented/enhanced by data from zbMATH Open. This attempts to reflect the references listed in the original paper as accurately as possible without claiming completeness or a perfect matching.