Long spin-1/2 noble gas coherence times in mm-sized anodically bonded batch-fabricated 3He-129Xe-87Rb cells
Abstract
As the only stable spin-1/2 noble gas isotopes, 3He and 129Xe are promising systems for inertial rotation sensing and searches for exotic spin couplings. Spin-1/2 noble gases have intrinsic coherence times on the order of hours to days, which allows for incredibly low frequency error of free-precession measurements. However relaxation in miniature cells is dominated by interactions with the cell wall, which limits the performance of a chip-scale sensor that uses noble gases. While 129Xe wall relaxation times have previously been limited to 10’s of seconds in mm-sized cells, we demonstrate the first anodically bonded batch-fabricated cells with dual 3He-129Xe isotopes and 87Rb in a 6 mm3 volume with 3He and 129Xe coherence times of, respectively, 4 h and 300 s. We use these microfabricated cells in a dual noble-gas comagnetometer and discuss its limits.
pacs:
32.30.Dx, 06.30.Gv,39.90.+dThe research and commercial development of minature high-performance atomic sensors [1, 2, 3, 4, 5] has naturally driven interest in chip-scale systems for hyperpolarization of noble gas nuclear spins [6, 7]. Compact noble-gas NMR systems are used in a variety of studies, including searches of short-range spin-dependent forces [8], inertial rotation sensing [9, 10, 11, 12, 13], magnetometry [14], and microfluidic detection [15, 16]. These applications use vapor cells that contain the readily available 129Xe or 131Xe that are hyperpolarized by spin exchange with optically pumped alkali metals. Noble-gas nuclei are notable for having extraordinarily long coherence times while having high densities, making the quantum projection frequency noise well below pHz levels [17], with the number of nuclei sampled and measurement time . The potential of noble gases for rotation measurements has long been considered [18, 19, 20], but more than one simultaneous measurement is needed to discern rotations of the apparatus from changes in the local magnetic field. Thus the use of a comagnetometer that samples the same magnetic field in the same volume is advantageous for rotation measurements done in a compact and cost-effective package. In principle the spin-1/2 isotopes 129Xe or 3He [21, 22, 23] are the best candidates for systematic-free rotation measurements, as higher-spin isotopes like 131Xe or 21Ne are susceptible to additional frequency shifts and relaxation mechanisms that can be deleterious [24, 25, 26, 27, 28]. Detection of nuclear spins at a quantum shot noise level is difficult to achieve. A popular and sensitive detection method that takes advantage of the wavefunction overlap of the optically addressable electronic state of an alkali metal with a noble gas nuclei [29, 30]. While backaction and relaxation from the alkali on the noble gas must be mitigated [31, 32], this method of detection is convenient because Rb alkali vapor is already present in these systems to hyperpolarize 3He and 129Xe through spin-exchange optical pumping.
Spin-1/2 noble gases intrinsically decohere very slowly through intraspecies collisional processes that form transient or persistent dimers which allow for dipole-dipole and spin-rotation relaxation [33, 34, 35]. Various extrinsic factors that cause nuclear relaxation include diffusion through magnetic field gradients, spin exchange and spin destruction of the noble gases with warm alkali vapors, and relaxation due to the cell wall. Given a particular coating or cell surface, the characteristic wall relaxation time scales linearly with surface-to-volume ratio and follows an Arrhenius temperature dependence. In small cells with a large surface-to-volume ratio, the noble-gas coherence times are often limited by interactions with the cell walls, with past studies showing 129Xe relaxation of 10’s of seconds [11]. We demonstrate batch fabrication of stemless anodically bonded cells that have a well-defined geometry and contain 3He and 129Xe with nuclear-spin coherence times of 4 hours and 300 s, respectively, a significant improvement in the 129Xe coherence time for micro-fabricated cells and the first successful detection of 3He signals in such cells. We then use these cells as a free-precession dual noble-gas comagnetometer in a laboratory-sized prototype for a chip-scale gyroscope, achieving a stability of 0.2 deg/h at 48 h.
For this study we make stemless cells shown in Fig. 1 by using a silicon wafer of thickness 2 mm, drilled with an array of 2 mm holes, machined with two 0.2 mm thick SD-2 aluminosilcate glass plates on each side [1, 36]. The wafer and glass are baked under high vacuum, which is crucial to obtain long 129Xe lifetimes. We first bond glass to one side of the wafer, and then introduce isotopically enriched 87Rb metal into the cells. Then the other side of the wafer is bonded to enclose the cell under a 1400:6.5:80 torr 3He:129Xe:N2 gas mixture in the bonding chamber. The is included for quenching during optical pumping of 87Rb. Heat applied during bonding can cause buffer gas pressure loss in cells of up to 30; we check the 3He and 87Rb densities by measuring the Rb absorption spectrum of the probe laser. A cryogenic storage system reclaims 3He from the bonding chamber, enabling a pathway for fabricating many low-cost devices. Anodically bonded glass on machined silicon also allows for excellent control of the cell geometry. Typical glass blown or optically contacted cells have a glass stem for cell filling and sealing [37, 10], which creates an inherent asymmetry in the cell shape. Some are able to lessen cell stem effects by plugging the stem with alkali metal [38] or a small piece of movable glass [39]. Others have made stemless cells by allowing 3He to diffuse through quartz walls at a high temperature [40]. The cell shape is an important consideration for precision measurements and chip-scale sensors that use noble-gas precession frequency measurements, as it affects the long-range dipolar magnetic interactions between spin-polarized nuclei [41]. Such interactions cause significant frequency shifts in precision comagnetometer measurements [42], where long-term drifts can be correlated to placement and magnitude of noble-gas polarization [43, 44, 45, 46, 47]. To study this dipolar effect, we recently used our cell fabrication process to make a slight wedge in the Si wafer to vary the height-to-diameter aspect ratios across many cells. We demonstrated the existance of an optimal aspect ratio that nulls the dipolar effect, as well as the existence of nuclear -coupling between different noble gases 3He-129Xe [44]. This -coupling in principle also provides a mechanism for relaxation and polarization transfer between the different noble gas species, although this has not yet been directly observed.
We include 87Rb in the cells in order to polarize nuclear spins by spin-exchange with 87Rb that is polarized by optical pumping using a circularly polarized laser beam parallel to a longitudinal bias magnetic field µT. We also detect noble-gas spin precession with a 87Rb magnetometer [48, 31, 49], which gives a high signal-to-noise ratio due to wavefunction overlap of the 87Rb with the noble gases [50, 51, 52, 53]. Since the cells have only a single optical axis, counter-propagating pump and probe beams are used with fast 87Rb magnetic field pulses to make a pulse-train magnetometer similar to that described in Ref. [31, 44]. For 87Rb magnetometer operation, the polarization of an 795 nm pump laser is alternated between and light at 13 kHz by an EOM. Synchronous 2 s long magnetic field pulses along the -axis (or any axis in the transverse plane) quickly Rabi flop the 87Rb polarization back and forth along . If the pulses are sufficiently fast and short, they can suppress alkali-alkali spin-exchange relaxation as well as precession of 87Rb spins around [31]. The 87Rb polarization along is detected with a probe beam that is detuned off the resonance, passing through the cell to a balanced polarimeter. The probe laser is shuttered by an AOM to open only during pulses to mitigate probe broadening. A DC or low frequency field parallel to the direction of the fast pulses delays or advances the 87Rb signal zero-crossing during the Rabi flop. This signal is measured by a lock-in amplifier referenced to half the EOM frequency with the lock-in output proportional to . The sensitivity of the 87Rb magnetometer is 300 fT/. We use sub-mW power from Photodigm DBR lasers through the active volume, similar to the powers from commercial VCSEL laser packages.
Although self-relaxation for the noble gases in our conditions yields coherence times of hundreds of hours for both 129Xe and 3He, our system is dominated by wall relaxation and Rb-noble gas interactions. To study 129Xe relaxation mechanisms, we first spin-exchange optically pump the 129Xe along the bias field for 30-50 s, and have negligible 3He polarization. A tipping pulse then places 129Xe transverse to and its precession is detected with the pulse-train 87Rb magnetometer. A representative signal from the lock-in amplifier is shown in Fig. 2a. We fit a given data set to the function to extract , and show 129Xe as a function of cell temperature and Rb density in Fig. 2b. In this cell we find the Rb absorption FWHM of 23.4 GHz corresponding to torr 3He [54]. From the slope in Fig. 2b we find a Rb-Xe spin-exchange rate of cm3/s. This value is in agreement with a calculation of the spin-exchange rate cm3/s based on previously measured cross-sections [55, 56]. The relaxation rate does not change significantly from the Rb-Xe spin-exchange rate across our temperature range, so we neglect any Arrhenius temperature dependence in our analysis. The inset of Fig. 2b shows the Rb magnetometer can shorten 129Xe by causing a Rb polarization gradient that 129Xe diffuses through. The additional relaxation depends on the 87Rb pump laser power and the accuracy of 87Rb pulses. Increasing the 87Rb pulse repetition rate decreases this relaxation because the Rb gradient is reversed more rapidly. For accurate measurements we use proper pulses and low pump power. The 3He coherence exceeds 129Xe by at least an order of magnitude, thus sufficient for our comagnetometer operation.
To study the feasibility of these long noble gas lifetime cells in a compact gyroscope we operate the noble gases in a free-precession comagnetometer, similar to measurements in Ref. [31] that were with larger glass-blown cells. For these measurements we hyperpolarize 3He and 129Xe along a bias field µT that is co-linear to the pump and probe beams. We then apply a tipping pulse that places 3He and 129Xe spins in a plane transverse to . The 87Rb pulse-train magnetometer detects the precession of both noble gases about as shown in Fig. 3. To find the rotation rate for a given shot with both measurement styles, we first find the effective free-precession frequencies of the noble gases and . We extract the rotation rate by taking the ratio and finding with [57]. After a measurement the noble gas spins are placed back along the bias field by dumping feedback from the lock-in signal [58]. Repeating this sequence, we run the comagnetometer for an extended period of time to determine its sensitivity and long-term stability. In Fig. 4 we compare the Allan deviations for a Ramsey-style sequence with active Rb depolarization and for measurements with the Rb -pulse train magnetometer continuously running. For the Ramsey-style measurement each shot takes about 115 s, with a 25 s inital and 45 s final detection period. We fit the detection period signals to decaying sine waves to determine the phases and with which the spins enter and leave the dark detection period = 45 sec. Assuming there are no significant changes in the precession frequency, we find the in-the-dark free-precession frequencies of the noble gases by taking , where is an integer determined from an estimate of the precession frequency. During the dark period a two-axis decoupling pulse train is used to mitigate noble-gas frequency shifts due to 87Rb back polarization and nulls Bloch-Siegert shifts introduced by the pulse train [31]. For continuous measurements each shot lasts about 50 s, and we fit two decaying sine waves to find and . In both measurement styles we find frequency uncertainty is limited by the 3He frequency error due to low steady-state 3He magnetization at a temperature that allows for long 129Xe , as higher temperatures cause greater Rb-Xe relaxation. The Ramsey-style measurement integrates for more than a day, longer than the continous method by about an order of magnitude, with both methods reaching around 0.2 deg/h precision before drifting. The uncertainties achieved here are about an order of magnitude worse than achieved in the same system for glass-blown cells with 100 times larger volume used in Ref. [31]. Using microfabricated cells with higher 3He pressure would improve the performance, as in the current cells the small steady-state magnetization becomes insufficient with practical shot-to-shot pumping periods. To determine expected gyroscope performance we can use Cramér-Rao lower bounds (CRLB) of a decaying sine wave [59, 60, 61] to estimate a lower bound for the rotation error
(1) |
For a decaying sine wave,
(2) |
where is the measurement time and SNR , where is the initial sine wave amplitude and is the spectral density of white Gaussian noise. and are factors depending on the measurement and relaxation time and that both approach unity as . For Ramsey-style detection in the limit of long , the optimal detection intervals are of the total measurement time and the overall statistical sensitivity is three times worse than for continuous detection of equal time. For finite relaxation one can show that
(3) |
where is used to for estimate of the trailing phase of the first detection period and for the leading phase of the second period. Using the signal height, noise, and relaxation times from Fig. 3, and considering detection, in-the-dark, and shot-to-shot times used in Fig. 4 we find a Cramér-Rao frequency uncertainty lower bound that corresponds to an angular random walk of 0.094 deg/ for a Ramsey-style measurement and 0.056 deg/ for continuous operation, about an order of magnitude better than we realized experimentally.
In conclusion, we demonstrate fabrication of miniature stemless anodically bonded vapor cells containing 3He, 129Xe, 87Rb, and N2 with long 129Xe and 3He coherence times. We use these cells in a dual noble-gas comagnetometer detected by an in situ 87Rb pulse-train magnetometer, and study the long-term stability of the system. Though far from fundamental limits, this system has great potential for high-precision, accurate rotation measurements in a small, low-cost package.
This work was funded by DARPA (Defense Advanced Research Project Agency) under contract FA8650-13-1-7326 and NSF Grant No. 1404325.
References
- Liew et al. [2004] L.-A. Liew, S. Knappe, J. Moreland, H. Robinson, L. Hollberg, and J. Kitching, Microfabricated alkali atom vapor cells, Appl. Phys. Lett. 84, 2694 (2004).
- Knappe et al. [2006] S. Knappe et al., J. Opt. A: Pure Appl. Opt. 8, S318 (2006).
- Kitching [2018] J. Kitching, Chip-scale atomic devices, Applied Physics Reviews 5, 031302 (2018), https://doi.org/10.1063/1.5026238 .
- Limes et al. [2020] M. Limes, E. Foley, T. Kornack, S. Caliga, S. McBride, A. Braun, W. Lee, V. Lucivero, and M. Romalis, Portable magnetometry for detection of biomagnetism in ambient environments, Phys. Rev. Applied 14, 011002 (2020).
- McGilligan et al. [2020] J. P. McGilligan, K. R. Moore, A. Dellis, G. D. Martinez, E. de Clercq, P. F. Griffin, A. S. Arnold, E. Riis, R. Boudot, and J. Kitching, Laser cooling in a chip-scale platform, Applied Physics Letters 117, 054001 (2020), https://doi.org/10.1063/5.0014658 .
- Ledbetter et al. [2008] M. Ledbetter, I. Savukov, D. Budker, V. Shah, S. Knappe, J. Kitching, D. Michalak, S. Xu, and A. Pines, Zero-field remote detection of nmr with a microfabricated atomic magnetometer, Proceedings of the National Academy of Sciences 105, 2286 (2008).
- Jiménez-Martínez et al. [2014] R. Jiménez-Martínez, D. J. Kennedy, M. Rosenbluh, E. A. Donley, S. Knappe, S. J. Seltzer, H. L. Ring, V. S. Bajaj, and J. Kitching, Optical hyperpolarization and nmr detection of 129 xe on a microfluidic chip, Nature communications 5, 1 (2014).
- Bulatowicz et al. [2013] M. Bulatowicz, R. Griffith, M. Larsen, J. Mirijanian, C. B. Fu, E. Smith, W. M. Snow, H. Yan, and T. G. Walker, Laboratory search for a long-range -odd, -odd interaction from axionlike particles using dual-species nuclear magnetic resonance with polarized and gas, Phys. Rev. Lett. 111, 102001 (2013).
- Donley [2010] E. A. Donley, Nuclear magnetic resonance gyroscopes, in 2010 IEEE Sensors Proc. (2010) p. 17.
- Larsen and Bulatowicz [2012] M. Larsen and M. Bulatowicz, Nuclear magnetic resonance gyroscope, in 2012 IEEE Int. Freq. Cont. Symp. Proc. (2012).
- Walker and Larsen [2016] T. Walker and M. Larsen, Chapter eight - spin-exchange-pumped {NMR} gyros, Adv. Atom, Mol. Opt. Phys. 65, 373 (2016).
- Buchs et al. [2018] G. Buchs, S. Karlen, T. Overstolz, N. Torcheboeuf, E. Onillon, J. Haesler, and D. L. Boiko, AIP Conf. Proc. 1936, 020011 (2018).
- Thrasher et al. [2019] D. A. Thrasher, S. S. Sorensen, J. Weber, M. Bulatowicz, A. Korver, M. Larsen, and T. G. Walker, Continuous comagnetometry using transversely polarized xe isotopes, Phys. Rev. A 100, 061403 (2019).
- Bulatowicz and Larsen [2012] M. Bulatowicz and M. Larsen, Compact atomic magnetometer for global navigation, in 2012 IEEE/ION PLANS Proc. (2012) p. 1088.
- Jiménez-Martínez et al. [2014] R. Jiménez-Martínez et al., Nat. Comm. 5, 3908 (2014).
- Kennedy et al. [2017] D. Kennedy et al., Sci. Rep. 7, 43994 (2017).
- Gentile et al. [2017] T. R. Gentile, P. J. Nacher, B. Saam, and T. G. Walker, Optically polarized , Rev. Mod. Phys. 89, 045004 (2017).
- Kastler [1973] A. Kastler, The hanle effect and its use for the measurements of very small magnetic fields, Nuclear Instruments and Methods 110, 259 (1973).
- Lam et al. [1983] L. K. Lam, E. Phillips, E. Kanegsberg, and G. W. Kamin, Application Of CW Single-Mode GaAlAs Lasers To Rb-Xe NMR Gyroscopes, in Fiber Optic and Laser Sensors I, Vol. 0412, edited by E. L. Moore and O. G. Ramer, International Society for Optics and Photonics (SPIE, 1983) pp. 272 – 276.
- Mehring et al. [1992] M. Mehring, A. Appelt, B. Menke, and P. Scheufler, High Precision Navigation 91: Proceedings of the 2nd International Workshop on High Precision Navigation, Stuttgart and Freudenstadt, 1991, edited by Linkwitz and Hangleiter (Dummler Verlag, 1992).
- Chupp et al. [1987] T. E. Chupp, M. E. Wagshul, K. P. Coulter, A. B. McDonald, and W. Happer, Polarized, high-density, gaseous targets, Phys. Rev. C 36, 2244 (1987).
- Stoner et al. [1996] R. E. Stoner, M. A. Rosenberry, J. T. Wright, T. E. Chupp, E. R. Oteiza, and R. L. Walsworth, Demonstration of a two species noble gas maser, Phys. Rev. Lett. 77, 3971 (1996).
- Bear et al. [2000] D. Bear, R. E. Stoner, R. L. Walsworth, V. A. Kostelecký, and C. D. Lane, Limit on lorentz and CPT violation of the neutron using a two-species noble-gas maser, Phys. Rev. Lett. 85, 5038 (2000).
- Chupp and Coulter [1985] T. E. Chupp and K. P. Coulter, Polarization of by spin exchange with optically pumped rb vapor, Phys. Rev. Lett. 55, 1074 (1985).
- Wu et al. [1987] Z. Wu, W. Happer, and J. M. Daniels, Coherent nuclear-spin interactions of adsorbed gas with surfaces, Phys. Rev. Lett. 59, 1480 (1987).
- Chupp et al. [1988] T. E. Chupp, E. R. Oteiza, J. M. Richardson, and T. R. White, Precision frequency measurements with polarized , , and atoms, Phys. Rev. A 38, 3998 (1988).
- Butscher et al. [1994] R. Butscher, G. Wäckerle, and M. Mehring, Nuclear quadrupole interaction of highly polarized gas phase 131xe with a glass surface, The Journal of Chemical Physics 100, 6923 (1994), https://doi.org/10.1063/1.467008 .
- Donley et al. [2009] E. A. Donley, J. L. Long, T. C. Liebisch, E. R. Hodby, T. A. Fisher, and J. Kitching, Phys. Rev. A 79, 013420 (2009).
- Walker and Happer [1997] T. G. Walker and W. Happer, Spin-exchange optical pumping of noble-gas nuclei, Rev. Mod. Phys. 69, 629 (1997).
- Appelt et al. [1998] S. Appelt, A. B.-A. Baranga, C. J. Erickson, M. V. Romalis, A. R. Young, and W. Happer, Theory of spin-exchange optical pumping of and , Phys. Rev. A 58, 1412 (1998).
- Limes et al. [2018] M. E. Limes, D. Sheng, and M. V. Romalis, Phys. Rev. Lett. 120, 033401 (2018).
- Korver et al. [2015] A. Korver, D. Thrasher, M. Bulatowicz, and T. G. Walker, Synchronous spin-exchange optical pumping, Phys. Rev. Lett. 115, 253001 (2015).
- Newbury et al. [1993] N. R. Newbury, A. S. Barton, G. D. Cates, W. Happer, and H. Middleton, Gaseous he magnetic dipolar spin relaxation, Phys. Rev. A 48, 4411 (1993).
- Chann et al. [2002] B. Chann, I. A. Nelson, L. W. Anderson, B. Driehuys, and T. G. Walker, molecular spin relaxation, Phys. Rev. Lett. 88, 113201 (2002).
- Anger et al. [2008] B. C. Anger, G. Schrank, A. Schoeck, K. A. Butler, M. S. Solum, R. J. Pugmire, and B. Saam, Gas-phase spin relaxation of , Phys. Rev. A 78, 043406 (2008).
- Dellis et al. [2016] A. Dellis, V. Shah, E. Donley, S. Knappe, and J. Kitching, Optics Letters 41, 2775 (2016).
- Eklund et al. [2008] E. J. Eklund, A. M. Shkel, S. Knappe, E. Donley, and J. Kitching, Glass-blown spherical microcells for chip-scale atomic devices, Sensors and Act. A: 143, 175 (2008).
- Lee et al. [2018] J. Lee, A. Almasi, and M. Romalis, Improved limits on spin-mass interactions, Phys. Rev. Lett. 120, 161801 (2018).
- Balabas et al. [2010] M. V. Balabas, T. Karaulanov, M. P. Ledbetter, and D. Budker, Polarized alkali-metal vapor with minute-long transverse spin-relaxation time, Phys. Rev. Lett. 105, 070801 (2010).
- Maul et al. [2016] A. Maul, P. Blümler, W. Heil, A. Nikiel, E. Otten, A. Petrich, and T. Schmidt, Rev. Sci. Instr. 87, 015103 (2016).
- Stoltz et al. [1995] E. Stoltz, J. Tannenhauser, and P. Nacher, J. Low Temp. Phys. 101, 839 (1995).
- Allmendinger et al. [2014] F. Allmendinger, W. Heil, S. Karpuk, W. Kilian, A. Scharth, U. Schmidt, A. Schnabel, Y. Sobolev, and K. Tullney, New limit on lorentz-invariance- and -violating neutron spin interactions using a free-spin-precession - comagnetometer, Phys. Rev. Lett. 112, 110801 (2014).
- Romalis et al. [2014] M. V. Romalis, D. Sheng, B. Saam, and T. G. Walker, Comment on “new limit on lorentz-invariance- and -violating neutron spin interactions using a free-spin-precession comagnetometer”, Phys. Rev. Lett. 113, 188901 (2014).
- Limes et al. [2019] M. E. Limes, N. Dural, M. V. Romalis, E. L. Foley, T. W. Kornack, A. Nelson, L. R. Grisham, and J. Vaara, Dipolar and scalar frequency shifts in stemless cells, Phys. Rev. A 100, 010501 (2019).
- Vaara and Romalis [2019] J. Vaara and M. V. Romalis, Calculation of scalar nuclear spin-spin coupling in a noble-gas mixture, Phys. Rev. A 99, 060501 (2019).
- Terrano et al. [2019] W. A. Terrano, J. Meinel, N. Sachdeva, T. E. Chupp, S. Degenkolb, P. Fierlinger, F. Kuchler, and J. T. Singh, Frequency shifts in noble-gas comagnetometers, Phys. Rev. A 100, 012502 (2019).
- Sachdeva et al. [2019] N. Sachdeva, I. Fan, E. Babcock, M. Burghoff, T. E. Chupp, S. Degenkolb, P. Fierlinger, S. Haude, E. Kraegeloh, W. Kilian, S. Knappe-Grüneberg, F. Kuchler, T. Liu, M. Marino, J. Meinel, K. Rolfs, Z. Salhi, A. Schnabel, J. T. Singh, S. Stuiber, W. A. Terrano, L. Trahms, and J. Voigt, New limit on the permanent electric dipole moment of using comagnetometry and squid detection, Phys. Rev. Lett. 123, 143003 (2019).
- Sheng et al. [2014] D. Sheng, A. Kabcenell, and M. V. Romalis, New classes of systematic effects in gas spin comagnetometers, Phys. Rev. Lett. 113, 163002 (2014).
- Zhivun et al. [2019] E. Zhivun, M. Bulatowicz, A. Hryciuk, and T. Walker, Dual-axis -pulse magnetometer with suppressed spin-exchange relaxation, Phys. Rev. Applied 11, 034040 (2019).
- Schaefer et al. [1989] S. R. Schaefer, G. D. Cates, T.-R. Chien, D. Gonatas, W. Happer, and T. G. Walker, Frequency shifts of the magnetic-resonance spectrum of mixtures of nuclear spin-polarized noble gases and vapors of spin-polarized alkali-metal atoms, Phys. Rev. A 39, 5613 (1989).
- Romalis and Cates [1998] M. V. Romalis and G. D. Cates, Accurate polarimetry using the rb zeeman frequency shift due to the spin-exchange collisions, Phys. Rev. A 58, 3004 (1998).
- Ma et al. [2011] Z. L. Ma, E. G. Sorte, and B. Saam, Collisional and frequency shifts in rb˘noble-gas mixtures, Phys. Rev. Lett. 106, 193005 (2011).
- Nahlawi et al. [2019] A. I. Nahlawi, Z. L. Ma, M. S. Conradi, and B. Saam, High-precision determination of the frequency-shift enhancement factor in rb-, Phys. Rev. A 100, 053415 (2019).
- Romalis et al. [1997] M. V. Romalis, E. Miron, and G. D. Cates, Pressure broadening of rb and lines by 3he, 4he, n2, and xe: Line cores and near wings, Phys. Rev. A 56, 4569 (1997).
- Nelson [2001] I. A. Nelson, Physics of practical spin-exchange optical pumping, Ph.D. thesis, University of Wisconsin–Madison (2001).
- Schrank et al. [2009] G. Schrank, Z. Ma, A. Schoeck, and B. Saam, Characterization of a low-pressure high-capacity flow-through polarizer, Phys. Rev. A 80, 063424 (2009).
- Makulski [2015] W. Makulski, 129xe and 131xe nuclear magnetic dipole moments from gas phase nmr spectra, Magn. Reson. Chem. 53, 273 (2015).
- Alem et al. [2013] O. Alem, K. L. Sauer, and M. V. Romalis, Spin damping in an rf atomic magnetometer, Phys. Rev. A 87, 013413 (2013).
- Chupp et al. [1994] T. E. Chupp, R. J. Hoare, R. L. Walsworth, and B. Wu, Spin-exchange-pumped and zeeman masers, Phys. Rev. Lett. 72, 2363 (1994).
- Ying-Xian Yao and Pandit [1995] Ying-Xian Yao and S. M. Pandit, Cramer-rao lower bounds for a damped sinusoidal process, IEEE Transactions on Signal Processing 43, 878 (1995).
- Gemmel et al. [2010] C. Gemmel, W. Heil, S. Karpuk, K. Lenz, C. Ludwig, Y. Sobolev, K. Tullney, M. Burghoff, W. Kilian, S. Knappe-Grüneberg, W. Müller, A. Schnabel, F. Seifert, L. Trahms, and S. Baeßler, Ultra-sensitive magnetometry based on free precession of nuclear spins, The European Physical Journal D 57, 303 (2010).