Lithography of aluminum coated PVDF annular array for photoacoustic endoscopy. (English) Zbl 1488.78007

Summary: Focused transducers are frequently used in photoacoustic endoscopy (PAE) to ensure high acoustic resolution beyond the depth of optical diffraction. Although most transducers in PAE are ceramic and focus-fixed, we here propose the polyvinylidine fluoride (PVDF) based annular array to reduce the fabrication cost, and to allow dynamic focusing for increased depth of field. In this work, a method of direct lithography on the aluminum coated PVDF films was used for the annular array fabrication. The PVDF annular array was built with a 110 \(\mu\)m thick aluminum coated PVDF film, which contained three independent rings of equal width within a 5.5 mm aperture size. Phantom experiments were conducted for field test, and a simple linear model was used to compare the acquired results in the acoustic field test. The device was used for demonstration in PAE application. Potential applications of the proposed method include the PAE imaging of several large human organs and lumens such as the gastrointestinal tract and the cervical canal.

MSC:

78A46 Inverse problems (including inverse scattering) in optics and electromagnetic theory
78-10 Mathematical modeling or simulation for problems pertaining to optics and electromagnetic theory
78A45 Diffraction, scattering
76Q05 Hydro- and aero-acoustics
68M07 Mathematical problems of computer architecture
92C55 Biomedical imaging and signal processing
Full Text: DOI

References:

[1] T. J. Yoon and Y. S. Cho. Recent advances in photoacoustic endoscopy. World Journal of Gas-trointestinal Endoscopy, 5(11):534-539, 2013.
[2] X. Lei, C. Duan, H. Xie, and H. Jiang. Miniature probe combining optical-resolution photoa-coustic microscopy and optical coherence tomography for in vivomicrocirculation study.Appl Opt, 52(9):1928-1931, 2013.
[3] J. M. Yang, K. Maslov, H. C. Yang, Q. Zhou, K. K. Shung, and L. V. Wang. Photoacoustic endoscopy. Optics Letters, 34(10):1591, 2009.
[4] C. Li, J. M. Yang, R. Chen, C. H. Yeh, L. Zhu, K. Maslov, Q. Zhou, K. K. Shung, and L. V. Wang. Urogenital photoacoustic endoscope. Optics Letters, 39(6):1473-6, 2014.
[5] L. Xi, X. Li, and H. Jiang. Variable-thickness multilayered polyvinylidene fluoride transducer with improved sensitivity and bandwidth for photoacoustic imaging. Applied Physics Letters, 101(17):602-5883, 2012.
[6] H. Yang, L. Xi, S. Sean, H. Xie, L. Yang, and H. Jiang. Handheld miniature probe integrating diffuse optical tomography with photoacoustic imaging through a mems scanning mirror. Biomedical Optics Express, 4(3):427-432, 2013.
[7] J. M. Cannata, T. A. Ritter, W. H. Chen, and R. H. Silverman. Design of efficient, broadband single-element (20-80 mhz) ultrasonic transducers for medical imaging applications. IEEE Transactions on Ultrasonics Ferroelectrics & Frequency Control, 50(11):1548, 2003.
[8] H. Wang, D. Xing, and L. Xiang.Photoacoustic imaging using an ultrasonic fresnel zone plate transducer. Journal of Physics D Applied Physics, 41(9):095111, 2008.
[9] C. Liu, F. Djuth, X. Li, R. Chen, Q. Zhou, and K. K. Shung. Micromachined high frequency pmn-pt/epoxy 1-3 composite ultrasonic annular array. Ultrasonics, 52(4):497, 2012.
[10] E. J. Gottlieb, J. M. Cannata, C. H. Hu, and K. K. Shung. Development of a high-frequency (¿ 50 mhz) copolymer annular-array, ultrasound transducer. IEEE Transactions on Ultrasonics Ferroelectrics & Frequency Control, 53(5):1037, 2006.
[11] R. G. Kolkman, E. Hondebrink, W. Steenbergen, T. G. van Leeuwen, and F. F. de Mul. Pho-toacoustic imaging of blood vessels with a double-ring sensor featuring a narrow angular aperture. Journal of Biomedical Optics, 9(6):1327, 2004.
[12] K. Passler, R. Nuster, S. Gratt, P. Burgholzer, and G. Paltauf. Piezoelectric annular array for large depth of field photoacoustic imaging. Biomedical Optics Express, 2(9):2655-2664, 2011.
[13] H. Yang and H. Jiang. Design and evaluation of a miniature probe integrating diffuse opti-cal tomography and electroencephalographic source localization. Applied Optics, 52(20):5036-5041, 2013.
[14] L. Xiang, L. Ji, T. Zhang, B. Wang, J. Yang, Q. Zhang, M. S. Jiang, J. Zhou, P. R. Carney, and H. Jiang. Noninvasive real time tomographic imaging of epileptic foci and networks. Neuroimage, 66(2):240-248, 2013.
[15] V. T. Chang, P. S. Cartwright, S. M. Bean, G. M. Palmer, R. C. Bentley, and N. Ramanujam. Quantitative physiology of the precancerous cervix in vivo through optical spectroscopy.Neo-plasia, 11(4):325-332, 2009.
[16] S. J. Carey, C. Brox-Nilsen, H. M. Lewis, C. M. Gregory, and J. V. Hatfield.Scanning head with 128-element 20-mhz pvdf linear array transducer.IEEE Transactions on Ultrasonics Ferroelectrics & Frequency Control, 56(8):1769-1777, 2009.
[17] M. Z. Sleva, W. D. Hunt, and R. D. Briggs. Focusing performance of epoxy-and air-acked polyvinylidene fluoride fresnel zone plates. Journal of the Acoustical Society of America, 96(3):1627-1633, 1994.
[18] K. Peng, L. He, B. Wang, and J. Xiao. Detection of cervical cancer based on photoacoustic imaging-the in-vitro results. Biomedical Optics Express, 6(1):135-143, 2015.
This reference list is based on information provided by the publisher or from digital mathematics libraries. Its items are heuristically matched to zbMATH identifiers and may contain data conversion errors. In some cases that data have been complemented/enhanced by data from zbMATH Open. This attempts to reflect the references listed in the original paper as accurately as possible without claiming completeness or a perfect matching.