State reference design and saturated control of doubly-fed induction generators under voltage dips. (English) Zbl 1366.93037

Summary: In this paper, the stator/rotor currents control problem of doubly-fed induction generator under faulty line voltage is carried out. Common grid faults cause a steep decline in the line voltage profile, commonly denoted as voltage dip. This point is critical for such kind of machines, having their stator windings directly connected to the grid. In this respect, solid methodological nonlinear control theory arguments are exploited and applied to design a novel controller, whose main goal is to improve the system behaviour during voltage dips, endowing it with low voltage ride through capability, a fundamental feature required by modern Grid Codes. The proposed solution exploits both feedforward and feedback actions. The feedforward part relies on suitable reference trajectories for the system internal dynamics, which are designed to prevent large oscillations in the rotor currents and command voltages, excited by line perturbations. The feedback part uses state measurements and is designed according to Linear Matrix Inequalities (LMI) based saturated control techniques to further reduce oscillations, while explicitly accounting for the system constraints. Numerical simulations verify the benefits of the internal dynamics trajectory planning, and the saturated state feedback action, in crucially improving the Doubly-Fed Induction Machine response under severe grid faults.

MSC:

93A30 Mathematical modelling of systems (MSC2010)
93C15 Control/observation systems governed by ordinary differential equations
93C95 Application models in control theory
93C10 Nonlinear systems in control theory
Full Text: DOI

References:

[1] DOI: 10.1137/1.9781611970777 · Zbl 0816.93004 · doi:10.1137/1.9781611970777
[2] DOI: 10.1109/TIE.2010.2098630 · doi:10.1109/TIE.2010.2098630
[3] DOI: 10.1109/TSTE.2015.2412176 · doi:10.1109/TSTE.2015.2412176
[4] Ekanayake J., Pow. Sys. Mag. pp 28– (2003)
[5] ENTSO-E, Network code requirements for grid connection applicable to all generators (2012)
[6] FERC U., Tech. Rep. (2005)
[7] DOI: 10.5772/12889 · doi:10.5772/12889
[8] DOI: 10.1109/TIE.2014.2326997 · doi:10.1109/TIE.2014.2326997
[9] DOI: 10.1049/ip-epa:20000442 · doi:10.1049/ip-epa:20000442
[10] DOI: 10.1016/j.aml.2005.09.005 · Zbl 1117.15011 · doi:10.1016/j.aml.2005.09.005
[11] DOI: 10.1109/TAC.2006.884942 · Zbl 1366.93439 · doi:10.1109/TAC.2006.884942
[12] DOI: 10.1007/978-1-4471-0549-7 · doi:10.1007/978-1-4471-0549-7
[13] DOI: 10.1016/j.renene.2009.09.008 · doi:10.1016/j.renene.2009.09.008
[14] Khalil H.K., Nonlinear systems, 2. ed. (1996)
[15] DOI: 10.1016/j.epsr.2008.02.018 · doi:10.1016/j.epsr.2008.02.018
[16] DOI: 10.1007/978-3-642-56649-3_11 · doi:10.1007/978-3-642-56649-3_11
[17] Lin Z., Control systems with actuator saturation (2001) · Zbl 1061.93003
[18] DOI: 10.1109/2943.999610 · doi:10.1109/2943.999610
[19] Nguyen T.D., Proceedings of IEEE international conference on power system technology pp 1– (2012)
[20] Novotny D.W., Vector control and dynamics of AC drives (1996)
[21] Pena R., IEE Proceedings - Electric Power Applications, 143 pp 308– (1996)
[22] DOI: 10.1109/TCST.2003.819590 · doi:10.1109/TCST.2003.819590
[23] DOI: 10.1016/S0967-0661(02)00285-X · doi:10.1016/S0967-0661(02)00285-X
[24] DOI: 10.1109/TEC.2009.2032169 · doi:10.1109/TEC.2009.2032169
[25] DOI: 10.1109/TPEL.2014.2369412 · doi:10.1109/TPEL.2014.2369412
[26] DOI: 10.1016/j.automatica.2009.04.022 · Zbl 1175.93075 · doi:10.1016/j.automatica.2009.04.022
[27] Vas P, Sensorless vector and direct torque control (1998)
[28] DOI: 10.1109/TIE.2012.2205354 · doi:10.1109/TIE.2012.2205354
[29] DOI: 10.1109/TPWRS.2013.2240707 · doi:10.1109/TPWRS.2013.2240707
[30] DOI: 10.1109/TPWRS.2011.2174387 · doi:10.1109/TPWRS.2011.2174387
[31] DOI: 10.1049/iet-rpg.2014.0252 · doi:10.1049/iet-rpg.2014.0252
This reference list is based on information provided by the publisher or from digital mathematics libraries. Its items are heuristically matched to zbMATH identifiers and may contain data conversion errors. In some cases that data have been complemented/enhanced by data from zbMATH Open. This attempts to reflect the references listed in the original paper as accurately as possible without claiming completeness or a perfect matching.