Control of grid connected photovoltaic systems with microinverters: new theoretical design and numerical evaluation. (English) Zbl 1390.93115

Summary: This paper addresses the problem of controlling grid connected photovoltaic (PV) systems that are driven with microinverters. The systems to be controlled consist of a solar panel, a boost dc-dc converter, a DC link capacitor, a single-phase full-bridge inverter, a filter inductor, and an isolation transformer. We seek controllers that are able to simultaneously achieve four control objectives, namely: (i) asymptotic stability of the closed loop control system; (ii) maximum power point tracking (MPPT) of the PV module; (iii) tight regulation of the DC bus voltage; and (iv) unity power factor (PF) in the grid. To achieve these objectives, a new multiloop nonlinear controller is designed using the backstepping design technique. A key feature of the control design is that it relies on an averaged nonlinear system model accounting, on the one hand, for the nonlinear dynamics of the underlying boost converter and inverter and, on the other, for the nonlinear characteristic of the PV panel. To achieve the MPPT objective, a power optimizer is designed that computes online the optimal PV panel voltage used as a reference signal by the PV voltage regulator. It is formally shown that the proposed controller meets all the objectives. This theoretical result is confirmed by numerical simulation tests.

MSC:

93A15 Large-scale systems
93A30 Mathematical modelling of systems (MSC2010)
93C15 Control/observation systems governed by ordinary differential equations
93B51 Design techniques (robust design, computer-aided design, etc.)

References:

[1] Krithiga, S., and N. G.Ammasai Gounden, “Power electronic configuration for the operation of PV system in combined grid‐connected and stand‐alone modes,” IET Power Electron., Vol. 7, No. 3, pp. 640-647 (2014).
[2] Akorede, M. F., H.Hizam, and E.Pouresmail, “Distributed energy resources and benefits to environment,” Renew. Sust. Energ. Rev., Vol. 14, pp. 724-734 (2010).
[3] El Fadil, H., F.Giri, A.Yahya, and H.Erguig, “Nonlinear control of hybrid photovoltaic/fuel cell distributed generation system,” Proc. 11th IFAC Int. Workshop Adapt. Learn. Control Signal Process., Caen, France, pp. 665-670 (2013).
[4] Vahidinasab, V., “Optimal distributed energy resources planning in a competitive electricity market: Multiobjective optimization and probabilistic design,” Renew. Energy, Vol. 66, pp. 354-363 (2014).
[5] Guggilam, S. S., C.Zhao, E.Dall’Anese, Y.Christine, and S. V.Dhople, “Optimizing power‐frequency droop characteristics of distributed energy resources,” IEEE Trans. Power Syst., Vol. PP, No. 99, pp. 1-1 (2017).
[6] Mastromauro, R., A.Liserre, M.Kerekes, and T.Dell’Aquila, “A single‐phase voltage‐controlled grid‐connected photovoltaic system with power quality conditioner functionality,” IEEE Trans. Ind. Electron., Vol. 56, No. 11, pp. 4436-4444 (2009).
[7] Gu, B., J.Dominic, J. S.Lai, C. L.Chen, T.LaBella, and B.Chen, “High reliability and efficiency single‐phase transformerless inverter for grid‐connected photovoltaic systems,” IEEE Trans. Power Electron., Vol. 28, No. 5, pp. 2235-2245 (2013).
[8] Yang, Y., F.Blaabjerg, and Z.Zou, “Benchmarking of grid fault modes in single‐phase grid‐connected photovoltaic systems,” IEEE Trans. Ind. Appl., Vol. 49, No. 5, pp. 2167-2176 (2013).
[9] Hu, H., S.Harb, N. H.Kutkut, Z. J.Shen, and I.Batarseh, “A single‐stage microinverter without using eletrolytic capacitors,” IEEE Trans. Power Electron., Vol. 28, No. 6, pp. 2677-2687 (2013).
[10] Mahmud, M. A., H. R.Pota, and M. J.Hossain, “Nonlinear current control scheme for a single‐phase grid‐connected photovoltaic system,” IEEE Trans. Sustain. Energ., Vol. 5, No. 1, pp. 218-227 (2014).
[11] Li, Y., and M.Ishikawa, “Statistical analysis of power system sensitivity under random penetration of photovoltaic generation,” Asian J. Control, Vol. 19, pp. 1688-1698 (2017). · Zbl 1386.93269
[12] Sera, D., L.Mathe, T.Kerekes, S. V.Spataru, and R.Teodorescu, “On the perturb‐and‐observe and incremental conductance MPPT methods for PV systems,” IEEE Trans. J. Photovoltaics, Vol. 3, No. 3, pp. 1070-1078 (2013).
[13] Fermia, N., D.Granozio, G.Petrone, and M.Vitelli, “Predictive & adaptive MPPT perturb and observe method,” IEEE Trans. Aerosp. Electron. Syst., Vol. 43, No. 3, pp. 934-950 (2007).
[14] Ishaque, K., Z.Salam, and G.Lauss, “The performance of perturb and observe and incremental conductance maximum power point tracking method under dynamic weather conditions,” Appl. Energy, Vol. 119, pp. 228-236 (2014).
[15] Lin, C.‐H., C.‐H.Huang, D.Yi‐Chun, and J.‐L.Chen, “Maximum photovoltaic power tracking for the PV array using the fractional‐order incremental conductance method,” Appl. Energy, Vol. 88, No. 12, pp. 4840-4847 (2011).
[16] Rajesh, R., and M.Carolin Mabel, “Efficiency analysis of a multi‐fuzzy logic controller for the determination of operating points in a PV system,” Sol. Energy, Vol. 99, pp. 77-87 (2014).
[17] Ammasai, G. N., S. A.Peter, H.Nallandula, and S.Krithiga, “Fuzzy logic controller with MPPT using line‐commutated inverter for three‐phase grid‐connected photovoltaic systems,” Renew. Energy, Vol. 34, No. 3, pp. 909-915 (2009).
[18] Hassaine, L., E. O.Lias, J.Quintero, and V.Salas, “Overview of power inverter topologies and control structures for grid connected photovoltaic systems,” Renew. Sust. Energ. Rev., Vol. 30, pp. 796-807 (2014).
[19] Ravi, A., P. S.Manoharan, and J.Vijay Anand, “Modeling and simulation of three phase multilevel inverter for grid connected photovoltaic systems,” Sol. Energy, Vol. 85, No. 11, pp. 2811-2818 (2011).
[20] XiongY., S.Qian, and J.Xu, “Single‐phase grid‐connected photovoltaic system based on boost inverter,” 2012 Asia‐Pacific Power Energ. Eng. Conf. (APPEEC), pp. 1‐3, 27‐29 (2012).
[21] Luo, A., Y.Chen, Z.Shuai, and C.Tu, “An improved reactive current detection and power control method for single‐phase photovoltaic grid‐connected DG system,” IEEE Trans. Energ. Convers., Vol. 28, No. 4, pp. 823-831 (2013).
[22] Menti, A., T.Zacharias, and J.Milias‐Argitis, “Harmonic distortion assessment for a single‐phase grid‐connected photovoltaic system,” Renew. Energy, Vol. 36, No. 1, pp. 360-368 (2011).
[23] Wu, L., Z.Zhao, and J.Liu, “A single‐stage three‐phase grid‐connected photovoltaic system with modified MPPT method and reactive power compensation,” IEEE Trans. Energy Convers., Vol. 22, No. 4, pp. 881-886 (2007).
[24] Enrique, J. M., E.Duran, M.Sidrach‐de‐Cardona, and J. M.Andujar, “Theoretical assessment of the maximum power point tracking efficiency of photovoltaic facilities with different converter topologies,” Sol. Energy, Vol. 81, pp. 31-38 (2007).
[25] Chen‐Chi, C., and C.Chieh‐Li, “Robust maximum power point tracking method for photovoltaic cells: A sliding mode control approach,” Sol. Energy, Vol. 83, pp. 1370-1378 (2009).
[26] El Fadil, H., and F.Giri, “Climatic sensorless maximum power point tracking in PV generation systems,” Control Eng. Practice, Vol. 19, No. 5, pp. 513-521 (2011).
[27] Oulcaid, M., H.El Fadil, A.Yahya, and F.Giri, “Maximum power point tracking algorithm for photovoltaic systems under partial shaded conditions,” Proc. 12th IFAC Int. Workshop Adapt. Learn. Control Signal Process. (ALCOSP‐2016), Eindhoven, Netherlands, pp. 217‐222 (2016).
[28] Krein, P. T., J.Bentsman, R. M.Bass, and B.Lesieutre, “On the use of averaging for analysis of power electronic system,” IEEE Trans. Power Electron., Vol. 5, No. 2, pp. 182-190 (1990).
[29] Krstic, M., I.Kanellakopoulos, and P. V.Kokotović, Nonlinear and Adaptive Control Design, John Wiley & Sons, NY (1995). · Zbl 0763.93043
[30] Lin, F.‐J., S.‐G.Chen, and I.‐F.Sun, “Adaptive backstepping control of six‐phase PMSM using functional link radial basis function network uncertainty observer,” Asian J. Control, doi:https://doi.org/10.1002/asjc.1521 (2017). · Zbl 1386.93164 · doi:10.1002/asjc.1521
[31] Tahri, A., H.El Fadil, F.Giri, and F.‐Z.Chaoui, “Nonlinear adaptive control of a hybrid fuel cell power system for electric vehicles - A Lyapunov stability based approach,” Asian J. Control, Vol. 18, pp. 166-177 (2016). · Zbl 1338.93199
[32] El Fadil, H., and F.Giri, “Backstepping Based Control of PWM DC-DC Boost Power Converters,” Int. J. Elec. Power Eng., Vol. 1, No. 5, pp. 479-485 (2007).
[33] El Fadil, H., and F.Giri, “Robust Control of Interleaved Synchronous PWM Buck Converters,” Int. J. Control and Intelligent Sys., Vol. 36, No. 4, pp. 340-346 (2008). · Zbl 1173.93327
[34] Yahya, A., H.El Fadil, J. M.Guerrero, F.Giri, H.Erguig, “Three‐Phase Grid‐Connected of Photovoltaic Generator Using Nonlinear Control,” Proc. 2014 IEEE Multi‐conf. Sys. and Control, Antibes, France, pp. 879-884 (2014).
This reference list is based on information provided by the publisher or from digital mathematics libraries. Its items are heuristically matched to zbMATH identifiers and may contain data conversion errors. In some cases that data have been complemented/enhanced by data from zbMATH Open. This attempts to reflect the references listed in the original paper as accurately as possible without claiming completeness or a perfect matching.