Skip to main content

Dual-Domain Iterative Network with Adaptive Data Consistency for Joint Denoising and Few-Angle Reconstruction of Low-Dose Cardiac SPECT

  • Conference paper
  • First Online:
Medical Image Learning with Limited and Noisy Data (MILLanD 2023)

Part of the book series: Lecture Notes in Computer Science ((LNCS,volume 14307))

Included in the following conference series:

Abstract

Myocardial perfusion imaging (MPI) by single-photon emission computed tomography (SPECT) is widely applied for the diagnosis of cardiovascular diseases. Reducing the dose of the injected tracer is essential for lowering the patient’s radiation exposure, but it will lead to increased image noise. Additionally, the latest dedicated cardiac SPECT scanners typically acquire projections in fewer angles using fewer detectors to reduce hardware expenses, potentially resulting in lower reconstruction accuracy. To overcome these challenges, we propose a dual-domain iterative network for end-to-end joint denoising and reconstruction from low-dose and few-angle projections of cardiac SPECT. The image-domain network provides a prior estimate for the projection-domain networks. The projection-domain primary and auxiliary modules are interconnected for progressive denoising and few-angle reconstruction. Adaptive Data Consistency (ADC) modules improve prediction accuracy by adaptively fusing the outputs of the primary and auxiliary modules. Experiments using clinical MPI data show that our proposed method outperforms existing image-, projection-, and dual-domain techniques, producing more accurate projections and reconstructions. Ablation studies confirm the significance of the image-domain prior estimate and ADC modules in enhancing network performance. Our source code is available at https://github.com/XiongchaoChen/DuDoNet-JointLD.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Subscribe and save

Springer+ Basic
$34.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or eBook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Chapter
USD 29.95
Price excludes VAT (USA)
eBook
USD 89.00
Price excludes VAT (USA)
Softcover Book
USD 119.99
Price excludes VAT (USA)

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Similar content being viewed by others

References

  1. Aghakhan Olia, N., et al.: Deep learning–based denoising of low-dose SPECT myocardial perfusion images: quantitative assessment and clinical performance. Eur. J. Nucl. Med. Mol. Imaging 49(5), 1508–1522 (2021). https://doi.org/10.1007/s00259-021-05614-7

    Article  Google Scholar 

  2. Amirrashedi, M., Sarkar, S., Ghadiri, H., Ghafarian, P., Zaidi, H., Ay, M.R.: A deep neural network to recover missing data in small animal pet imaging: comparison between sinogram-and image-domain implementations. In: 2021 IEEE 18th International Symposium on Biomedical Imaging (ISBI), pp. 1365–1368. IEEE (2021)

    Google Scholar 

  3. Chan, C., et al.: The impact of system matrix dimension on small FOV SPECT reconstruction with truncated projections. Med. Phys. 43(1), 213–224 (2016)

    Article  Google Scholar 

  4. Chen, X., et al.: Cross-vender, cross-tracer, and cross-protocol deep transfer learning for attenuation map generation of cardiac SPECT. J. Nucl. Cardiol. 29(6), 3379–3391 (2022)

    Article  MathSciNet  Google Scholar 

  5. Chen, X., Liu, C.: Deep-learning-based methods of attenuation correction for SPECT and PET. J. Nucl. Cardiol. 1–20 (2022). https://doi.org/10.1007/s12350-022-03007-3

  6. Chen, X., Peng, Z., Valadez, G.H.: DD-CISENet: dual-domain cross-iteration squeeze and excitation network for accelerated MRI reconstruction. arXiv preprint arXiv:2305.00088 (2023)

  7. Chen, X., et al.: Ct-free attenuation correction for dedicated cardiac SPECT using a 3d dual squeeze-and-excitation residual dense network. J. Nucl. Cardiol. 29(5), 2235–2250 (2022)

    Article  Google Scholar 

  8. Chen, X., et al.: Dusfe: dual-channel squeeze-fusion-excitation co-attention for cross-modality registration of cardiac SPECT and CT. Med. Image Anal. 88, 102840 (2023)

    Article  Google Scholar 

  9. Chen, X., et al.: Dual-branch squeeze-fusion-excitation module for cross-modality registration of cardiac SPECT and ct. In: International Conference on Medical Image Computing and Computer-Assisted Intervention. pp. 46–55. Springer (2022). https://doi.org/10.1007/978-3-031-16446-0_5

  10. Chen, X., et al.: Dudoss: Deep-learning-based dual-domain sinogram synthesis from sparsely sampled projections of cardiac SPECT. Med. Phys. 50, 89–103 (2022)

    Google Scholar 

  11. Chen, X., et al.: Direct and indirect strategies of deep-learning-based attenuation correction for general purpose and dedicated cardiac spect. Eur. J. Nucl. Med. Mol. Imaging 49(9), 3046–3060 (2022)

    Article  Google Scholar 

  12. Chlemper, J., Caballero, J., Hajnal, J., Price, A., Rueckert, D.: A deep cascade of convolutional neural networks for dynamic MR image reconstructio. IEEE Trans. Med. Imaging 37, 491–503 (2017)

    Article  Google Scholar 

  13. Danad, I., et al.: Comparison of coronary CT angiography, SPECT, pet, and hybrid imaging for diagnosis of ischemic heart disease determined by fractional flow reserve. JAMA Cardiol. 2(10), 1100–1107 (2017)

    Article  Google Scholar 

  14. Einstein, A.J.: Effects of radiation exposure from cardiac imaging: how good are the data? J. Am. College Cardiol. 59(6), 553–565 (2012)

    Article  Google Scholar 

  15. GE-HealthCare: Ge myospect es: A perfect fit for today’s practice of cardiology. Available at https://www.gehealthcare.com/products/molecular-imaging/myospect (2023)

  16. Henzlova, M.J., Duvall, W.L., Einstein, A.J., Travin, M.I., Verberne, H.J.: ASNC imaging guidelines for SPECT nuclear cardiology procedures: Stress, protocols, and tracers. J. Nucl. Cardiol. 23, 606–639 (2016)

    Article  Google Scholar 

  17. Hu, J., Shen, L., Sun, G.: Squeeze-and-excitation networks. In: Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition, pp. 7132–7141 (2018)

    Google Scholar 

  18. Niu, S., et al.: Sparse-view x-ray CT reconstruction via total generalized variation regularization. Phys. Med. Bio. 59(12), 2997 (2014)

    Article  Google Scholar 

  19. Oktay, O., et al.: Attention u-net: learning where to look for the pancreas. arXiv preprint arXiv:1804.03999 (2018)

  20. Paszke, A., et al.: Pytorch: an imperative style, high-performance deep learning library. Adv. Neural Inf. Process. Syst. 32 (2019)

    Google Scholar 

  21. Ramon, A.J., Yang, Y., Pretorius, P.H., Johnson, K.L., King, M.A., Wernick, M.N.: Improving diagnostic accuracy in low-dose SPECT myocardial perfusion imaging with convolutional denoising networks. IEEE Trans. Med. Imaging 39(9), 2893–2903 (2020)

    Article  Google Scholar 

  22. Ronneberger, O., Fischer, P., Brox, T.: U-Net: convolutional networks for biomedical image segmentation. In: Navab, N., Hornegger, J., Wells, W.M., Frangi, A.F. (eds.) MICCAI 2015. LNCS, vol. 9351, pp. 234–241. Springer, Cham (2015). https://doi.org/10.1007/978-3-319-24574-4_28

    Chapter  Google Scholar 

  23. Shiri, I., et al.: Standard SPECT myocardial perfusion estimation from half-time acquisitions using deep convolutional residual neural networks. J. Nucl. Cardiol. 28(6), 2761–2779 (2020). https://doi.org/10.1007/s12350-020-02119-y

    Article  Google Scholar 

  24. Sun, J., Du, Y., Li, C., Wu, T.H., Yang, B., Mok, G.S.: Pix2pix generative adversarial network for low dose myocardial perfusion SPECT denoising. Quant. Imaging Med. Sur. 12(7), 3539 (2022)

    Article  Google Scholar 

  25. Sun, J., et al.: Deep learning-based denoising in projection-domain and reconstruction-domain for low-dose myocardial perfusion SPECT. J. Nucl. Cardiol. 1–16 (2022)

    Google Scholar 

  26. Wang, Y., et al.: 3D conditional generative adversarial networks for high-quality pet image estimation at low dose. Neuroimage 174, 550–562 (2018)

    Article  Google Scholar 

  27. Whiteley, W., Gregor, J.: CNN-based pet sinogram repair to mitigate defective block detectors. Phys. Med. Bio. 64(23), 235017 (2019)

    Article  Google Scholar 

  28. Wu, J., Liu, C.: Recent advances in cardiac SPECT instrumentation and imaging methods. Phys. Med. Bio. 64(6), 06TR01 (2019)

    Google Scholar 

  29. Zhou, B., Zhou, S.K.: Dudornet: learning a dual-domain recurrent network for fast mri reconstruction with deep t1 prior. In: Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition, pp. 4273–4282 (2020)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Xiongchao Chen .

Editor information

Editors and Affiliations

1 Electronic supplementary material

Below is the link to the electronic supplementary material.

Supplementary material 1 (pdf 1134 KB)

Rights and permissions

Reprints and permissions

Copyright information

© 2023 The Author(s), under exclusive license to Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Chen, X. et al. (2023). Dual-Domain Iterative Network with Adaptive Data Consistency for Joint Denoising and Few-Angle Reconstruction of Low-Dose Cardiac SPECT. In: Xue, Z., et al. Medical Image Learning with Limited and Noisy Data. MILLanD 2023. Lecture Notes in Computer Science, vol 14307. Springer, Cham. https://doi.org/10.1007/978-3-031-44917-8_5

Download citation

  • DOI: https://doi.org/10.1007/978-3-031-44917-8_5

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-031-47196-4

  • Online ISBN: 978-3-031-44917-8

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics