Abstract
The acoustic field distributions and the convergent beams generated by the planar-structure Fresnel zone transducers on solid surface are investigated. Because only 0 and 180 degree phase transducers are used, an imaging system with the Fresnel zoom lens could work at very high frequency, which overcomes the frequency limit of the traditional phased array acoustic imaging system. Simulation results are given to illustrate the acoustic field distributions along the focal axis and the whole plane as well. Based on the principle of scanning of the focus with the change of frequency for the excited signal, an experimental imaging system is also built. Acoustic Fresnel zone transducers are fabricated at center frequency of 400 MHz. Measurements and detections of the known hole flaws at different depths of the fused quartz sample are presented to show that the imaging system with Fresnel zoom lens could move its focus by only changing the frequency of the excited signal.
Similar content being viewed by others
References
Quate C F, Atalar A, Wickramasinghe H K. Acoustic microscopy with mechanical scanning — A review. Proc IEEE, 1979, 67: 1092–1097
Yamamoto H, Tanaka S, Sato K. Silicon acoustic lens for scanning acoustic microscope (SAM). In: Digest of Technical Papers, International Conference on Solid-State Sensors and Actuators. New York: IEEE Press, 1991. 853–858
Kino G S. Acoustic Waves: Devices, Imaging & Analog Signal Processing. New Jersey: Prentice-Hall Inc, 1987. Chapter 3
Qiao D H, et al. ZnO planar focusing transducer on using Fresnel array. Acoust Imag, 1993, 20: 353–357
Yamada K, Shimuzi H. Planar-structure focusing lens for acoustic microscope. In: Proc. IEEE Ultrasonic Symp. San Francisco: IEEE Press, 1985. 755–758
Yamada K, Shimuzi H, Minakata M. Planar structure focusing lens for operation at 200 MHz and its application to the reflection mode acoustic microscope. In: Proc. IEEE Ultrasonic Symp. Williamsburg: IEEE Press, 1986. 745–750
Yamada K, Sugiyama T, Shimuzi H. Theoretical consideration on acoustic field formed by Fresnel-zone-type focusing radiator. Jpn J Appl Phys, 1987, 26: 180–187
Jiang R L, Wang C H. The focusing properties of the Fresnel zone array. Prog Nat Sci (in Chinese), 2001, 11(11): 1157–1164
Hadimioglu B, Rawson E G, Lujan R, et al. High-efficiency Fresnel acoustic lenses. In: Proc. IEEE Ultrasonics Symp. Baltimore: IEEE Press, 1993. 579–582
Wu J Y, Wang C H. The focusing and scanning properties of the Fresnel transducer array in solid. Chin J Phys, 1988, 39(10): 1575–1579
Qiao D H, Wang C H. Study on focusing properties of acoustic beams in solid. In: Proc. IEEE Ultrasonics Symp. Cannes: IEEE Press, 1994. 2: 1071–1074
Wang C H, Qiao D H. Investigation on the focusing of acoustic beams generated by the Fresnel transducer array. Chin J Acoust, 1999, 24(4): 351–366
Qiao D H, Wang C H. Design of the purely acoustic spectrum analyzer based on the bulk acoustic waves. In: Proc. of Ultrasonic Electronics, Chongqing, China, 1991. 56–59
Miller G F, Pursey H. The field and radiation impedance of mechanical radiator on the free surface of a semi-infinite isotropic solid. Proc R Soc, 1963, 223: 521–541
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Qiao, D., Li, S. & Wang, C. High frequency acoustic microscopy with Fresnel zoom lens. SCI CHINA SER G 50, 41–52 (2007). https://doi.org/10.1007/s11433-007-0002-5
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/s11433-007-0002-5