-
Quantitative in vitro to in vivo extrapolation for human toxicology and drug development
Authors:
Luca Cattelani,
Giusy del Giudice,
Angela Serra,
Michele Fratello,
Laura Aliisa Saarimäki,
Vittorio Fortino,
Antonio Federico,
Periklis Tsiros,
Marika Mannerström,
Tarja Toimela,
Tommaso Serchi,
Iseult Lynch,
Philip Doganis,
Haralambos Sarimveis,
Dario Greco
Abstract:
Traditional animal testing for toxicity is expensive, time consuming, ethically questioned, sometimes inaccurate because of the necessity to extrapolate from animal to human, and in most cases not formally validated according to modern standards. This is driving regulatory bodies and companies in backing alternative methods focusing on in silico and in vitro approaches. These are complex to implem…
▽ More
Traditional animal testing for toxicity is expensive, time consuming, ethically questioned, sometimes inaccurate because of the necessity to extrapolate from animal to human, and in most cases not formally validated according to modern standards. This is driving regulatory bodies and companies in backing alternative methods focusing on in silico and in vitro approaches. These are complex to implement and validate, and their wide adoption is not yet established despite legal directives providing an imperative. It is difficult to link a cell level response to effects on a whole organism, but the advances in high-throughput toxicogenomics towards elucidating the mechanism of action of substances are gradually reducing this gap and fostering the adoption of Next Generation Safety Assessment approaches. Quantitative in vitro to in vivo extrapolation (QIVIVE) methods hold the promise to reveal how to use in vitro -omics data to predict the potential for in vivo toxicity. They could improve lead compounds prioritisation, reduce time and costs, also in numbers of animal lives, and help with the complexity of extrapolating between species. We provide a description of QIVIVE state of the art, including how the problems of dosing and timing are being approached, how in silico simulation can take into account the variability of individuals, and how multiple techniques can be integrated to face complex tasks like the prediction of long term toxicity, including a close look into the open problems and challenges ahead.
△ Less
Submitted 10 January, 2024; v1 submitted 6 January, 2024;
originally announced January 2024.
-
Design Considerations for 3RRR Parallel Robots with Lightweight, Approximate Static-Balancing
Authors:
Giuseppe Del Giudice,
Garrison L. H. Johnston,
Nabil Simaan
Abstract:
Balancing parallel robots throughout their workspace while avoiding the use of balancing masses and respecting design practicality constraints is difficult. Medical robots demand such compact and lightweight designs. This paper considers the difficult task of achieving optimal approximate balancing of a parallel robot throughout a desired task-based dexterous workspace using balancing springs only…
▽ More
Balancing parallel robots throughout their workspace while avoiding the use of balancing masses and respecting design practicality constraints is difficult. Medical robots demand such compact and lightweight designs. This paper considers the difficult task of achieving optimal approximate balancing of a parallel robot throughout a desired task-based dexterous workspace using balancing springs only. While it is possible to achieve perfect balancing in a path, only approximate balancing may be achieved without the addition of balancing masses. Design considerations for optimal robot base placement and the effects of placement of torsional balancing springs are presented. Using a modal representation for the balancing torque requirements, we use recent results on the design of wire-wrapped cam mechanisms to achieve balancing throughout a task-based workspace. A simulation study shows that robot base placement can have a detrimental effect on the attainability of a practical design solution for static balancing. We also show that optimal balancing using torsional springs is best achieved when all springs are at the actuated joints and that the wire-wrapped cam design can significantly improve the performance of static balancing. The methodology presented in this paper provides practical design solutions that yield simple, lightweight and compact designs suitable for medical applications where such traits are paramount.
△ Less
Submitted 22 June, 2023;
originally announced June 2023.
-
First measurement of the surface tension of a liquid scintillator based on Linear Alkylbenzene (HYBLENE 113)
Authors:
SHiP SBT collaboration,
J. Alt,
J. Arutinov,
O. Bezshyyko,
T. Bretz,
A. Brignoli,
A. Conaboy,
P. Deucher,
F. De Paola,
G. del Giudice,
C. di Cristo,
O. Fecarotta,
A. Fiorillo,
H. Fischer,
H. Glückler,
C. Grewing,
A. Hollnagel,
H. Lacker,
A. Miano,
G. Natour,
V. Orlov,
A. Prota,
F. Rehbein,
A. Reghunath,
A. Salzano
, et al. (7 additional authors not shown)
Abstract:
We measured the surface tension of linear alkylbenzene (LAB) HYBLENE 113 mixed with Diphenyloxazole (PPO) as well as of pure LAB HYBLENE 113 as part of material studies for the liquid-scintillator based surround background tagger (SBT) in the proposed SHiP experiment. The measurement was performed using the iron wire method and the surface tension for linear alkyl benzene HYBLENE 113 plus PPO was…
▽ More
We measured the surface tension of linear alkylbenzene (LAB) HYBLENE 113 mixed with Diphenyloxazole (PPO) as well as of pure LAB HYBLENE 113 as part of material studies for the liquid-scintillator based surround background tagger (SBT) in the proposed SHiP experiment. The measurement was performed using the iron wire method and the surface tension for linear alkyl benzene HYBLENE 113 plus PPO was found to be $(30.0\pm0.6)$ mN/m $22.0\pm 0.5$ °C and for pure HYBLENE 113, $(29.2\pm 0.6)$ mN/m at $21.0\pm 0.5$ °C.
△ Less
Submitted 4 April, 2022; v1 submitted 27 January, 2022;
originally announced January 2022.
-
Simplified Kinematics of Continuum Robot Equilibrium Modulation via Moment Coupling Effects and Model Calibration
Authors:
Long Wang,
Giuseppe Del Giudice,
Nabil Simaan
Abstract:
Recently, a new concept for continuum robots capable of producing macro-scale and micro-scale motion has been presented. These robots achieve their multi-scale motion capabilities by coupling direct-actuation of push-pull back-bones for macro motion with indirect actuation whereby the equilibrium pose is altered to achieve micro-scale motion. This paper presents a first attempt at explaining the m…
▽ More
Recently, a new concept for continuum robots capable of producing macro-scale and micro-scale motion has been presented. These robots achieve their multi-scale motion capabilities by coupling direct-actuation of push-pull back-bones for macro motion with indirect actuation whereby the equilibrium pose is altered to achieve micro-scale motion. This paper presents a first attempt at explaining the micro-motion capabilities of these robots from a modeling perspective. This paper presents the macro and micro motion kinematics of a single segment continuum robot by using statics coupling effects among its sub-segments. Experimental observations of the micro-scale motion demonstrate a turning point behavior which could not be explained well using the current modeling methods. We present a simplistic modeling approach that introduces two calibration parameters to calibrate the moment coupling effects among the sub segments of the robot. It is shown that these two parameters can reproduce the turning point behavior at the micro-scale. The instantaneous macro and micro scale kinematics Jacobians and the calibration parameters identification Jacobian are derived. The modeling approach is verified against experimental data showing that our simplistic modeling approach can capture the experimental motion data with RMS position error of 5.82 micrometers if one wishes to fit the entire motion profile with the turning point. If one chooses to exclude motions past the turning point, our model can fit the experimental data with an accuracy of 4.76 micrometers.
△ Less
Submitted 9 June, 2019;
originally announced June 2019.