Statistical position reconstruction for RPC-based thermal neutron detectors
Authors:
A. Morozov,
L. M. S. Margato,
V. Solovov,
A. Blanco,
J. Saraiva,
T. Wilpert,
K. Zeitelhack,
K. Roemer,
C. Höglund,
L. Robinson,
R. Hall-Wilton
Abstract:
Multilayer position-sensitive 10B-RPC thermal neutron detectors offer an attractive combination of sub-millimeter spatial resolution and high (>50%) detection efficiency. Here we describe a new position reconstruction method based on a statistical approach. Using experimental data, we compare the performance of this method with that of the centroid reconstruction. Both methods result in a similar…
▽ More
Multilayer position-sensitive 10B-RPC thermal neutron detectors offer an attractive combination of sub-millimeter spatial resolution and high (>50%) detection efficiency. Here we describe a new position reconstruction method based on a statistical approach. Using experimental data, we compare the performance of this method with that of the centroid reconstruction. Both methods result in a similar image linearity/uniformity and spatial resolution. However, the statistical method allows to improve the image quality at the detector periphery, offers more flexible event filtering and allows to develop automatic quality monitoring procedures for early detection of situations when a change in the detector operation conditions starts to affect reconstruction quality.
△ Less
Submitted 26 July, 2021; v1 submitted 28 May, 2021;
originally announced May 2021.
-
Towards high-rate RPC-based thermal neutron detectors using low-resistivity electrodes
Authors:
L. M. S. Margato,
A. Morozov,
A. Blanco,
P. Fonte,
L. Lopes,
J. Saraiva,
K. Zeitelhack,
R. Hall-Wilton,
C. Höglund,
L. Robinson,
P. Svensson,
L. Naumann,
K. Roemer,
D. Stach,
Th. Wilpert
Abstract:
We present experimental results on the counting rate measurements for several single-gap $^{10}$B lined resistive plate chambers ($^{10}$B-RPCs) with anodes made from standard float glass, low resistivity glass and ceramic. The measurements were performed at the V17 monochromatic neutron beamline (3.35 Ȧ) at the Helmholtz-Zentrum Berlin. For the $^{10}$B-RPCs with 0.28 mm thick float glass a maxim…
▽ More
We present experimental results on the counting rate measurements for several single-gap $^{10}$B lined resistive plate chambers ($^{10}$B-RPCs) with anodes made from standard float glass, low resistivity glass and ceramic. The measurements were performed at the V17 monochromatic neutron beamline (3.35 Ȧ) at the Helmholtz-Zentrum Berlin. For the $^{10}$B-RPCs with 0.28 mm thick float glass a maximum counting rate density of about $8\times 10^{3}$ $Hz/cm^{2}$ was obtained. In the case of low resistivity glass and ceramic, the counting rate density did not deviate from linear dependence on the neutron flux up to the maximum flux available at this beamline and exceeded a value of $3\times 10^{4}$ $Hz/cm^{2}$.
△ Less
Submitted 1 April, 2021;
originally announced April 2021.
-
Multilayer $^{10}B$-RPC neutron imaging detector
Authors:
L. M. S. Margato,
A. Morozov,
A. Blanco,
P. Fonte,
L. Lopes,
K. Zeitelhack,
R. Hall-Wilton,
C. Höglund,
L. Robinson,
S. Schmidt,
P. Svensson
Abstract:
Resistive plate chambers (RPC) lined with $^{10}B_{4}$C neutron converters is a promising cost effective technology for position-sensitive thermal neutron detection capable to outperform $^{3}$He-based detectors in terms of spatial resolution and timing. However, as for the other types of gaseous detectors with a single layer of $^{10}B_{4}$C at normal beam incidence, the detection efficiency to t…
▽ More
Resistive plate chambers (RPC) lined with $^{10}B_{4}$C neutron converters is a promising cost effective technology for position-sensitive thermal neutron detection capable to outperform $^{3}$He-based detectors in terms of spatial resolution and timing. However, as for the other types of gaseous detectors with a single layer of $^{10}B_{4}$C at normal beam incidence, the detection efficiency to thermal neutrons of a single-gap $^{10}B$-RPC is only about 6%. Aiming to overcome this limitation, we introduce a multi-layer $^{10}B$-RPCs detector with a stack of ten double-gap hybrid RPCs. A description of the detector design and the results of its characterization performed at the TREFF neutron beamline at the FRM II neutron facility are presented. The results demonstrate that the detection efficiency exceeds 60% for neutrons with a wavelength of 4.7 Å and the spatial resolution (FWHM) is about 0.25 mm and 0.35 mm in the X and Y direction, respectively.
△ Less
Submitted 26 May, 2020; v1 submitted 3 February, 2020;
originally announced February 2020.
-
Boron-10 lined RPCs for sub-millimeter resolution thermal neutron detectors: Feasibility study in a thermal neutron beam
Authors:
L. M. S. Margato,
A. Morozov,
A. Blanco,
P. Fonte,
F. A. F. Fraga,
B. Guerard,
R. Hall-Wilton,
C. Höglund,
A. Mangiarotti,
L. Robinson,
S. Schmidt,
K. Zeitelhack
Abstract:
The results of an experimental feasibility study of a position sensitive thermal neutron detector based on a resistive plate chamber (RPC) are presented. The detector prototype features a thin-gap (0.35 mm) hybrid RPC with an aluminium cathode lined with a 2 $μ$m thick $^{10}B{_4}C$ neutron converter layer enriched in $^{10}B$ and a float glass anode. A detection efficiency of ${\approx}$ 6.2…
▽ More
The results of an experimental feasibility study of a position sensitive thermal neutron detector based on a resistive plate chamber (RPC) are presented. The detector prototype features a thin-gap (0.35 mm) hybrid RPC with an aluminium cathode lined with a 2 $μ$m thick $^{10}B{_4}C$ neutron converter layer enriched in $^{10}B$ and a float glass anode. A detection efficiency of ${\approx}$ 6.2 ${\%}$ was measured for the neutron beam ($λ$ =2.5 $Å$) at normal incidence. A spatial resolution better than 0.5 mm FWHM was demonstrated.
△ Less
Submitted 25 September, 2018;
originally announced September 2018.
-
TPC-like readout for thermal neutron detection using a GEM-detector
Authors:
Bernhard Flierl,
Otmar Biebel,
Ralf Hertenberger,
Karl Zeitelhack
Abstract:
Spatial resolution of less than 200 um is challenging for thermal neutron detection. A novel readout scheme based on the time-projection-chamber (TPC) concept is used in a gaseous electron multiplier (GEM) detector. Thermal neutrons are captured in a single 2 um thick Boron-10 converter cathode and secondary Helium and Lithium ions are produced with a combined energy of 2.8 MeV. These ions have su…
▽ More
Spatial resolution of less than 200 um is challenging for thermal neutron detection. A novel readout scheme based on the time-projection-chamber (TPC) concept is used in a gaseous electron multiplier (GEM) detector. Thermal neutrons are captured in a single 2 um thick Boron-10 converter cathode and secondary Helium and Lithium ions are produced with a combined energy of 2.8 MeV. These ions have sufficient energy to form straight tracks of several mm length. With a time resolving 2-dimensional readout of 400 um pitch in both directions, based on APV25 chips, the ions are tracked and their respective origin in the cathode converter foil is reconstructed. Using an Ar-CO2 93:7% gas mixture, a resolution of 100 um (FWHM 235 um) has been observed with a triple GEM-detector setup at the Garching neutron source (FRMII) for neutrons of 4.7 Angstrom.
△ Less
Submitted 8 September, 2015;
originally announced September 2015.
-
Geant4 based simulations for novel neutron detector development
Authors:
Thomas Kittelmann,
Irina Stefanescu,
Kalliopi Kanaki,
Mirko Boin,
Richard Hall-Wilton,
Karl Zeitelhack
Abstract:
A Geant4-based Python/C++ simulation and coding framework, which has been developed and used in order to aid the R&D efforts for thermal neutron detectors at neutron scattering facilities, is described. Built upon configurable geometry and generator modules, it integrates a general purpose object oriented output file format with meta-data, developed in order to facilitate a faster turn-around time…
▽ More
A Geant4-based Python/C++ simulation and coding framework, which has been developed and used in order to aid the R&D efforts for thermal neutron detectors at neutron scattering facilities, is described. Built upon configurable geometry and generator modules, it integrates a general purpose object oriented output file format with meta-data, developed in order to facilitate a faster turn-around time when setting up and analysing simulations. Also discussed are the extensions to Geant4 which have been implemented in order to include the effects of low-energy phenomena such as Bragg diffraction in the polycrystalline support materials of the detector. Finally, an example application of the framework is briefly shown.
△ Less
Submitted 5 November, 2013;
originally announced November 2013.
-
A 10B-based neutron detector with stacked Multiwire Proportional Counters and macrostructured cathodes
Authors:
I. Stefanescu,
Y. Abdullahi,
J. Birch,
I. Defendi,
R. Hall-Wilton,
C. Hoglund,
L. Hultman,
M. Zee,
K. Zeitelhack
Abstract:
We present the results of the measurements of the detection efficiency for a 4.7 Å neutron beam incident upon a detector incorporating a stack of up to five MultiWire Proportional Counters (MWPC) with Boron-coated cathodes. The cathodes were made of Aluminum and had a surface exhibiting millimeter-deep V-shaped grooves of 45°, upon which the thin Boron film was deposited by DC magnetron sputtering…
▽ More
We present the results of the measurements of the detection efficiency for a 4.7 Å neutron beam incident upon a detector incorporating a stack of up to five MultiWire Proportional Counters (MWPC) with Boron-coated cathodes. The cathodes were made of Aluminum and had a surface exhibiting millimeter-deep V-shaped grooves of 45°, upon which the thin Boron film was deposited by DC magnetron sputtering. The incident neutrons interacting with the converter layer deposited on the sidewalls of the grooves have a higher capture probability, owing to the larger effective absorption film thickness. This leads to a higher overall detection efficiency for the grooved cathode when compared to a cathode with a flat surface. Both the experimental results and the predictions of the GEANT4 model suggests that a 5-counter detector stack with coated grooved cathodes has the same efficiency as a 7-counter stack with flat cathodes. The reduction in the number of counters in the stack without altering the detection efficiency will prove highly beneficial for large-area position-sensitive detectors for neutron scattering applications, for which the cost-effective manufacturing of the detector and associated readout electronics is an important objective. The proposed detector concept could be a technological option for one of the new chopper spectrometers and other instruments planned to be built at the future European Spallation Source in Sweden. These results with macrostructured cathodes generally apply not just to MWPCs but to other gaseous detectors as well.
△ Less
Submitted 30 September, 2013;
originally announced September 2013.
-
Projectile fragmentation of 129Xe at Elab=790 AMeV
Authors:
J. Reinhold,
J. Friese,
H. -J. Koerner,
R. Schneider,
K. Zeitelhack,
H. Geissel,
A. Magel,
G. Muenzenberg,
K. Suemmerer
Abstract:
We have measured production yields and longitudinal momentum distributions of projectile-like fragments in the reaction 129Xe + 27Al at an energy of Elab=790 AMeV. Production cross sections higher than expected from systematics were observed for nuclei in the neutron-deficient tails of the isotopic distributions. A comparison with previously measured data from the fragmentation of 136Xe ions sho…
▽ More
We have measured production yields and longitudinal momentum distributions of projectile-like fragments in the reaction 129Xe + 27Al at an energy of Elab=790 AMeV. Production cross sections higher than expected from systematics were observed for nuclei in the neutron-deficient tails of the isotopic distributions. A comparison with previously measured data from the fragmentation of 136Xe ions shows that the production yields strongly depend on the neutron excess of the projectile with respect to the line of beta-stability. The momentum distributions exhibit a dependence on the fragment neutron-to-proton ratio in isobaric chains, which was not expected from systematics so far. This can be interpreted by a higher excitation of the projectile during the formation of neutron-deficient fragments.
△ Less
Submitted 29 March, 1998;
originally announced March 1998.