Pilot tone-guided focused navigation for free-breathing whole-liver fat-water and T2* quantification
Authors:
Adèle LC Mackowiak,
Christopher W Roy,
Mariana BL Falcão,
Mario Bacher,
Aurélien Bustin,
Jérôme Yerly,
Peter Speier,
Matthias Stuber,
Naïk Vietti-Violi,
Jessica AM Bastiaansen
Abstract:
Purpose To achieve whole-liver motion-corrected fat fraction (FF) and R2* quantification with a 3-minute free-breathing (FB) 3D radial isotropic acquisition, for increased organ coverage, ease-of-use, and patient comfort. Methods A FB 3D radial multiecho gradient-echo liver acquisition with integrated Pilot Tone (PT) navigation and NTE=8 echoes was reconstructed with a motion-correction algorithm…
▽ More
Purpose To achieve whole-liver motion-corrected fat fraction (FF) and R2* quantification with a 3-minute free-breathing (FB) 3D radial isotropic acquisition, for increased organ coverage, ease-of-use, and patient comfort. Methods A FB 3D radial multiecho gradient-echo liver acquisition with integrated Pilot Tone (PT) navigation and NTE=8 echoes was reconstructed with a motion-correction algorithm based on focused navigation and guided by PT signals (PT-fNAV), with and without a denoising step. Fat fraction (FF) and R2* quantification using a graph cut algorithm was performed on the motion-corrected whole-liver multiecho volumes. Volunteer experiments (n=10) at 1.5T included reference 3D and 2D Cartesian breath-hold (BH) acquisitions. Image sharpness was assessed to evaluate the quality of motion correction with PT-fNAV, compared to a motion-resolved reconstruction. Fat-water images and parametric maps were compared to BH reference acquisitions following Cartesian trajectories, and to a routinely used clinical software (MRQuantiF). Results The image sharpness provided by PT-fNAV (with and without denoising) was similar in end-expiratory motion-resolved reconstructions. The 3D radial FB FF maps compared well with reference BH 3D Cartesian maps (bias +0.7%, limits of agreement (LOA) [-2.5; 4.0]%) and with 2D quantification with MRQuantiF (-0.2%, LOA [-1.1; 0.6]%). While expected visual deviations between proposed FB and reference BH R2* maps were observed, no significant differences were found in quantitative analyses. Conclusion A 3D radial technique with retrospective motion correction by PT-fNAV enabled FF and R2* quantification of the whole-liver at 1.5T. The FB whole-liver acquisition at isotropic spatial resolution compared in accuracy with BH techniques, enabling 3D assessment of steatosis in individuals with limited respiratory capabilities.
△ Less
Submitted 8 December, 2023;
originally announced December 2023.
-
Motion-resolved fat-fraction mapping with whole-heart free-running multiecho gre and pilot tone
Authors:
Adèle L. C. Mackowiak,
Christopher W. Roy,
Jérôme Yerly,
Mariana B. L. Falcão,
Mario Bacher,
Peter Speier,
Davide Piccini,
Matthias Stuber,
Jessica A. M. Bastiaansen
Abstract:
PURPOSE To develop free-running multi-echo GRE for cardiac- and respiratory-motion-resolved whole-heart fat fraction quantification. METHODS Multi-echo readouts optimized for water-fat separation and quantification were integrated within a non-ECG-triggered free-breathing 3D radial GRE acquisition. Pilot Tone navigation was used to extract cardiac and respiratory motion states. Following a XD-GRAS…
▽ More
PURPOSE To develop free-running multi-echo GRE for cardiac- and respiratory-motion-resolved whole-heart fat fraction quantification. METHODS Multi-echo readouts optimized for water-fat separation and quantification were integrated within a non-ECG-triggered free-breathing 3D radial GRE acquisition. Pilot Tone navigation was used to extract cardiac and respiratory motion states. Following a XD-GRASP based image reconstruction of the separate echoes, fat fraction, water fraction, R2star and B0 maps, as well as fat and water images, were generated with a maximum likelihood fitting algorithm using graph cuts. The acquisition, reconstruction and post-processing framework was tested in 10 healthy volunteers at 1.5T and compared to a free-breathing ECG-triggered 5-echo acquisition. RESULTS The acquisition was successfully validated in vivo, with motion compensation achieved over all collected echoes, in both respiratory and cardiac dimensions. Pilot Tone navigation provided respiratory and cardiac signals in good agreement (r=0.954 and r=0.783, respectively) with self-gating signal extraction based on the MR data of the first echo. The framework enabled pericardial fat imaging and quantification across the cardiac cycle, revealing a decrease in apparent FF at systole across volunteers. 3D motion-resolved fat fraction maps showed good correlation with reference ECG-triggered measurements, as well as significant difference in measurements performed with NTE = 4 and NTE = 8 echoes (P < 0.0001 in chest fat and P < 0.01 in pericardial fat). CONCLUSION Volunteer experiments at 1.5T demonstrated the feasibility of a whole-heart free-running fat-fraction mapping technique for cardiac MRI in a 6 min scan time, with a resolution of 2mm3 isotropic.
△ Less
Submitted 12 April, 2023; v1 submitted 12 October, 2022;
originally announced October 2022.
-
FaBiAN: A Fetal Brain magnetic resonance Acquisition Numerical phantom
Authors:
Hélène Lajous,
Christopher W. Roy,
Tom Hilbert,
Priscille de Dumast,
Sébastien Tourbier,
Yasser Alemán-Gómez,
Jérôme Yerly,
Thomas Yu,
Hamza Kebiri,
Kelly Payette,
Jean-Baptiste Ledoux,
Reto Meuli,
Patric Hagmann,
Andras Jakab,
Vincent Dunet,
Mériam Koob,
Tobias Kober,
Matthias Stuber,
Meritxell Bach Cuadra
Abstract:
Accurate characterization of in utero human brain maturation is critical as it involves complex and interconnected structural and functional processes that may influence health later in life. Magnetic resonance imaging is a powerful tool to investigate equivocal neurological patterns during fetal development. However, the number of acquisitions of satisfactory quality available in this cohort of s…
▽ More
Accurate characterization of in utero human brain maturation is critical as it involves complex and interconnected structural and functional processes that may influence health later in life. Magnetic resonance imaging is a powerful tool to investigate equivocal neurological patterns during fetal development. However, the number of acquisitions of satisfactory quality available in this cohort of sensitive subjects remains scarce, thus hindering the validation of advanced image processing techniques. Numerical phantoms can mitigate these limitations by providing a controlled environment with a known ground truth. In this work, we present FaBiAN, an open-source Fetal Brain magnetic resonance Acquisition Numerical phantom that simulates clinical T2-weighted fast spin echo sequences of the fetal brain. This unique tool is based on a general, flexible and realistic setup that includes stochastic fetal movements, thus providing images of the fetal brain throughout maturation comparable to clinical acquisitions. We demonstrate its value to evaluate the robustness and optimize the accuracy of an algorithm for super-resolution fetal brain magnetic resonance imaging from simulated motion-corrupted 2D low-resolution series as compared to a synthetic high-resolution reference volume. We also show that the images generated can complement clinical datasets to support data-intensive deep learning methods for fetal brain tissue segmentation.
△ Less
Submitted 6 September, 2021;
originally announced September 2021.
-
Free-running SIMilarity-Based Angiography (SIMBA) for simplified anatomical MR imaging of the heart
Authors:
John Heerfordt,
Kevin K. Whitehead,
Jessica A. M. Bastiaansen,
Lorenzo Di Sopra,
Christopher W. Roy,
Jérôme Yerly,
Bastien Milani,
Mark A. Fogel,
Matthias Stuber,
Davide Piccini
Abstract:
Purpose: Whole-heart MRA techniques typically target pre-determined motion states and address cardiac and respiratory dynamics independently. We propose a novel fast reconstruction algorithm, applicable to ungated free-running sequences, that leverages inherent similarities in the acquired data to avoid such physiological constraints.
Theory and Methods: The proposed SIMilarity-Based Angiography…
▽ More
Purpose: Whole-heart MRA techniques typically target pre-determined motion states and address cardiac and respiratory dynamics independently. We propose a novel fast reconstruction algorithm, applicable to ungated free-running sequences, that leverages inherent similarities in the acquired data to avoid such physiological constraints.
Theory and Methods: The proposed SIMilarity-Based Angiography (SIMBA) method clusters the continuously acquired k-space data in order to find a motion-consistent subset that can be reconstructed into a motion-suppressed whole-heart MRA. Free-running 3D radial datasets from six ferumoxytol-enhanced scans of pediatric cardiac patients and twelve non-contrast scans of healthy volunteers were reconstructed with a non-motion-suppressed regridding of all the acquired data (All Data), our proposed SIMBA method, and a previously published free-running framework (FRF) that uses cardiac and respiratory self-gating and compressed sensing. Images were compared for blood-myocardium interface sharpness, contrast ratio, and visibility of coronary artery ostia.
Results: Both the fast SIMBA reconstruction (~20s) and the FRF provided significantly higher blood-myocardium sharpness than All Data (P<0.001). No significant difference was observed among the former two. Significantly higher blood-myocardium contrast ratio was obtained with SIMBA compared to All Data and FRF (P<0.01). More coronary ostia could be visualized with both SIMBA and FRF than with All Data (All Data: 4/36, SIMBA: 30/36, FRF: 33/36, both P<0.001) but no significant difference was found between the first two.
Conclusion: The combination of free-running sequences and the fast SIMBA reconstruction, which operates without a priori assumptions related to physiological motion, forms a simple workflow for obtaining whole-heart MRA with sharp anatomical structures.
△ Less
Submitted 13 July, 2020;
originally announced July 2020.
-
Time-Dependent Deep Image Prior for Dynamic MRI
Authors:
Jaejun Yoo,
Kyong Hwan Jin,
Harshit Gupta,
Jerome Yerly,
Matthias Stuber,
Michael Unser
Abstract:
We propose a novel unsupervised deep-learning-based algorithm for dynamic magnetic resonance imaging (MRI) reconstruction. Dynamic MRI requires rapid data acquisition for the study of moving organs such as the heart. Existing reconstruction methods suffer from restrictions either in the model design or in the absence of ground-truth data, resulting in low image quality. We introduce a generalized…
▽ More
We propose a novel unsupervised deep-learning-based algorithm for dynamic magnetic resonance imaging (MRI) reconstruction. Dynamic MRI requires rapid data acquisition for the study of moving organs such as the heart. Existing reconstruction methods suffer from restrictions either in the model design or in the absence of ground-truth data, resulting in low image quality. We introduce a generalized version of the deep-image-prior approach, which optimizes the network weights to fit a sequence of sparsely acquired dynamic MRI measurements. Our method needs neither prior training nor additional data. In particular, for cardiac images, it does not require the marking of heartbeats or the reordering of spokes. The key ingredients of our method are threefold: 1) a fixed low-dimensional manifold that encodes the temporal variations of images; 2) a network that maps the manifold into a more expressive latent space; and 3) a convolutional neural network that generates a dynamic series of MRI images from the latent variables and that favors their consistency with the measurements in k-space. Our method outperforms the state-of-the-art methods quantitatively and qualitatively in both retrospective and real fetal cardiac datasets. To the best of our knowledge, this is the first unsupervised deep-learning-based method that can reconstruct the continuous variation of dynamic MRI sequences with high spatial resolution.
△ Less
Submitted 25 January, 2021; v1 submitted 3 October, 2019;
originally announced October 2019.
-
Compressed Sensing with Signal Averaging for Improved Sensitivity and Motion Artifact Reduction in Fluorine-19 MRI
Authors:
Emeline Darçot,
Jérôme Yerly,
Tom Hilbert,
Roberto Colotti,
Elena Najdenovska,
Tobias Kober,
Matthias Stuber,
Ruud B. van Heeswijk
Abstract:
Fluorine-19 (19F) MRI of injected perfluorocarbon emulsions (PFCs) allows for the non-invasive quantification of inflammation and cell tracking, but suffers from a low signal-to-noise ratio and extended scan time. To address this limitation, we tested the hypothesis that a 19F MRI pulse sequence that combines a specific undersampling regime with signal averaging has increased sensitivity and robus…
▽ More
Fluorine-19 (19F) MRI of injected perfluorocarbon emulsions (PFCs) allows for the non-invasive quantification of inflammation and cell tracking, but suffers from a low signal-to-noise ratio and extended scan time. To address this limitation, we tested the hypothesis that a 19F MRI pulse sequence that combines a specific undersampling regime with signal averaging has increased sensitivity and robustness against motion artifacts compared to a non-averaged fully-sampled dataset, when both are reconstructed with compressed sensing. To this end, numerical simulations and phantom experiments were performed to characterize the point spread function (PSF) of undersampling patterns and the vulnerability to noise of acquisition-reconstruction strategies with paired numbers of x signal averages and acceleration factor x (NAx-AFx). At all investigated noise levels, the DSC of the acquisition-reconstruction strategies strongly depended on the regularization parameters and acceleration factor. In phantoms, motion robustness of an NA8-AF8 undersampling pattern versus NA1-AF1 was evaluated with simulated and real motions. Differences were assessed with Dice similarity coefficients (DSC), and were consistently higher for NA8-AF8 compared to NA1-AF1 strategy, for both simulated and real cyclic motions (P<0.001). Both acquisition-reconstruction strategies were validated in vivo in mice (n=2) injected with perfluoropolyether. These images displayed a sharper delineation of the liver with the NA8-AF8 strategy than with the NA1-AF1 strategy. In conclusion, we validated the hypothesis that in 19F MRI, the combination of undersampling and averaging improves both the sensitivity and the robustness against motion artifacts compared to a non-averaged fully-sampled dataset, when both are reconstructed with compressed sensing.
△ Less
Submitted 8 October, 2020; v1 submitted 10 September, 2019;
originally announced September 2019.
-
Natively Fat-Suppressed 5D Whole-Heart MRI with a Radial Free-Running Fast-Interrupted Steady-State (FISS) Sequence at 1.5T and 3T
Authors:
Jessica AM Bastiaansen,
Davide Piccini,
Lorenzo Di Sopra,
Christopher W Roy,
Robert R Edelman,
Ioannis Koktzoglou,
Jerome Yerly,
Matthias Stuber
Abstract:
Purpose: To implement, optimize and test fast interrupted steady-state (FISS) for natively fat-suppressed free-running 5D whole-heart MRI at 1.5T and 3T. Methods: FISS was implemented for fully self-gated free-running cardiac- and respiratory-motion-resolved radial imaging of the heart at 1.5T and 3T. Numerical simulations and phantom scans were performed to compare fat suppression characteristics…
▽ More
Purpose: To implement, optimize and test fast interrupted steady-state (FISS) for natively fat-suppressed free-running 5D whole-heart MRI at 1.5T and 3T. Methods: FISS was implemented for fully self-gated free-running cardiac- and respiratory-motion-resolved radial imaging of the heart at 1.5T and 3T. Numerical simulations and phantom scans were performed to compare fat suppression characteristics and to determine parameter ranges (readouts per FISS module (NR) and repetition time (TR)) for effective fat suppression. Subsequently, free-running FISS data were collected in ten healthy volunteers. All acquisitions were compared with a continuous bSSFP version of the same sequence, and both fat suppression and scan times were analyzed. Results: Simulations demonstrate a variable width and location of suppression bands in FISS that was dependent on TR and NR. For a fat suppression bandwidth of 100Hz and NR below 8, simulations demonstrated that a TR between 2.2ms and 3.0ms is required at 1.5T while a range of 3.0ms to 3.5ms applies at 3T. Fat signal increases with NR. These findings were corroborated in phantom experiments. In volunteers, fat SNR was significantly decreased using FISS compared with bSSPF at both field strengths. After protocol optimization, high-resolution (1.1mm x 1.1mm x 1.1mm) 5D whole-heart free-running FISS can be performed with effective fat suppression in under 8 min at 1.5T and 3T at a modest scan time increase compared to bSSFP.Conclusion: An optimal FISS parameter range was determined enabling natively fat-suppressed 5D whole-heart free-running MRI with a single continuous scan at 1.5T and 3T, demonstrating potential for cardiac imaging and noncontrast angiography.
△ Less
Submitted 8 March, 2019;
originally announced March 2019.