-
First bromine doped cryogenic implosion at the National Ignition Facility
Authors:
A. C. Hayes,
G. Kyrala,
M. Gooden,
J. B. Wilhelmy,
L. Kot,
P. Volegov,
C. Wilde,
B. Haines,
Gerard Jungman,
R. S. Rundberg,
D. C. Wilson,
C. Velsko,
W. Cassata,
E. Henry,
C. Yeamans,
C. Cerjan,
T. Ma,
T. Doppner,
A. Nikroo,
O. Hurricane,
D. Callahan,
D. Hinkel,
D. Schneider,
B. Bachmann,
F. Graziani
, et al. (7 additional authors not shown)
Abstract:
We report on the first experiment dedicated to the study of nuclear reactions on dopants in a cryogenic capsule at the National Ignition Facility (NIF). This was accomplished using bromine doping in the inner layers of the CH ablator of a capsule identical to that used in the NIF shot N140520. The capsule was doped with 3$\times$10$^{16}$ bromine atoms. The doped capsule shot, N170730, resulted in…
▽ More
We report on the first experiment dedicated to the study of nuclear reactions on dopants in a cryogenic capsule at the National Ignition Facility (NIF). This was accomplished using bromine doping in the inner layers of the CH ablator of a capsule identical to that used in the NIF shot N140520. The capsule was doped with 3$\times$10$^{16}$ bromine atoms. The doped capsule shot, N170730, resulted in a DT yield that was 2.6 times lower than the undoped equivalent. The Radiochemical Analysis of Gaseous Samples (RAGS) system was used to collect and detect $^{79}$Kr atoms resulting from energetic deuteron and proton ion reactions on $^{79}$Br. RAGS was also used to detect $^{13}$N produced dominantly by knock-on deuteron reactions on the $^{12}$C in the ablator. High-energy reaction-in-flight neutrons were detected via the $^{209}$Bi(n,4n)$^{206}$Bi reaction, using bismuth activation foils located 50 cm outside of the target capsule. The robustness of the RAGS signals suggest that the use of nuclear reactions on dopants as diagnostics is quite feasible.
△ Less
Submitted 7 July, 2023;
originally announced July 2023.
-
First measurement of the $^{10}{\rm B}(α,n)^{13}{\rm N}$ reaction in an inertial confinement fusion implosion at the National Ignition Facility: Initial steps toward the development of a radiochemistry mix diagnostic
Authors:
D. Lonardoni,
J. P. Sauppe,
S. H. Batha,
N. Birge,
T. Bredeweg,
M. Freeman,
V. Geppert-Kleinrath,
M. E. Gooden,
A. C. Hayes,
H. Huang,
G. Jungman,
B. D. Keenan,
L. Kot,
K. D. Meaney,
T. Murphy,
C. Velsko,
C. B. Yeamans,
H. D. Whitley,
C. Wilde,
J. B. Wilhelmy
Abstract:
We report the first measurement of the $^{10}{\rm B}(α,n)^{13}{\rm N}$ reaction in a polar-direct-drive exploding pusher (PDXP) at the National Ignition Facility (NIF). This work is motivated by the need to develop alternative mix diagnostics, radiochemistry being the focus here. The target is composed of a $65/35\,\rm at.\,\%$ deuterium-tritium (DT) fill surrounded by a roughly $30\,μ\rm m$ thick…
▽ More
We report the first measurement of the $^{10}{\rm B}(α,n)^{13}{\rm N}$ reaction in a polar-direct-drive exploding pusher (PDXP) at the National Ignition Facility (NIF). This work is motivated by the need to develop alternative mix diagnostics, radiochemistry being the focus here. The target is composed of a $65/35\,\rm at.\,\%$ deuterium-tritium (DT) fill surrounded by a roughly $30\,μ\rm m$ thick beryllium ablator. The inner portion of the beryllium ablator is doped with $10\,\rm at.\,\%$ of $^{10}{\rm B}$. Radiation-hydrodynamics calculations were performed in 1D to optimize both the remaining boron rho-R and the DT neutron yield. A charged-particle transport post-processor has been developed to study $α$-induced reactions on the ablator material. Results indicate a large $^{13}{\rm N}$ production from $α$-induced reactions on $^{10}{\rm B}$, measurable by the radiochemical analysis of gaseous samples system at the NIF. The PDXP target N201115-001 was successfully fielded on the NIF, and nitrogen from the $^{10}{\rm B}(α,n)^{13}{\rm N}$ reaction was measured. The $^{13}{\rm N}$ production yield, as well as the DT neutron yield, was, however, lower than expected. Some of the reduced yields can be explained by the oblate shape, but the ratios of the various radiochemical signals are not commensurate with expectations based on a simple reduction of the 1D results. Preliminary 2D radiation-hydrodynamics computations are consistent with the experimental measurements, and work is ongoing to extend the radiochemistry analysis into higher dimensions.
△ Less
Submitted 17 May, 2022; v1 submitted 18 November, 2021;
originally announced November 2021.
-
Comparison of ablators for the polar direct drive exploding pusher platform
Authors:
Heather D. Whitley,
G. Elijah Kemp,
Charles Yeamans,
Zachary Walters,
Brent E. Blue,
Warren Garbett,
Marilyn Schneider,
R. Stephen Craxton,
Emma M. Garcia,
Patrick W. McKenty,
Maria Gatu-Johnson,
Kyle Caspersen,
John I. Castor,
Markus Däne,
C. Leland Ellison,
James Gaffney,
Frank R. Graziani,
John Klepeis,
Natalie Kostinski,
Andrea Kritcher,
Brandon Lahmann,
Amy E. Lazicki,
Hai P. Le,
Richard A. London,
Brian Maddox
, et al. (14 additional authors not shown)
Abstract:
We examine the performance of pure boron, boron carbide, high density carbon, and boron nitride ablators in the polar direct drive exploding pusher (PDXP) platform. The platform uses the polar direct drive configuration at the National Ignition Facility to drive high ion temperatures in a room temperature capsule and has potential applications for plasma physics studies and as a neutron source. Th…
▽ More
We examine the performance of pure boron, boron carbide, high density carbon, and boron nitride ablators in the polar direct drive exploding pusher (PDXP) platform. The platform uses the polar direct drive configuration at the National Ignition Facility to drive high ion temperatures in a room temperature capsule and has potential applications for plasma physics studies and as a neutron source. The higher tensile strength of these materials compared to plastic enables a thinner ablator to support higher gas pressures, which could help optimize its performance for plasma physics experiments, while ablators containing boron enable the possiblity of collecting addtional data to constrain models of the platform. Applying recently developed and experimentally validated equation of state models for the boron materials, we examine the performance of these materials as ablators in 2D simulations, with particular focus on changes to the ablator and gas areal density, as well as the predicted symmetry of the inherently 2D implosion.
△ Less
Submitted 30 December, 2020; v1 submitted 28 June, 2020;
originally announced June 2020.
-
The first cryogenic DT layered, beryllium capsule implosion at the National Ignition Facility
Authors:
D. C. Wilson,
J. L. Kline,
S. A. Yi,
A. N. Simakov,
G. A. Kyrala,
R. E. Olson,
T. S. Perry,
F. E. Merrill,
S. Batha,
A. B. Zylstra,
D. A. Callahan,
W. Cassata,
E. L. Dewald,
S. W. Haan,
D. E. Hinkel,
O. A. Hurricane,
N. Izumi,
T. Ma,
A. G. MacPhee,
J. L. Milovich,
J. E. Ralph,
J. R. Rygg,
M. B. Schneider,
S. Sepke,
D. J. Strozzi
, et al. (4 additional authors not shown)
Abstract:
NIF experiments with Be capsules have followed a path of the highly successful "high-foot" CH capsules. Several keyhole and ConA targets preceeded a DT layered shot. In addition to backscatter subtraction, laser drive multipliers were needed to match observed X-ray drives. Those for the picket (0.95), trough (1.0) and second pulse (0.80) were determined by VISAR measurements. The time dependence o…
▽ More
NIF experiments with Be capsules have followed a path of the highly successful "high-foot" CH capsules. Several keyhole and ConA targets preceeded a DT layered shot. In addition to backscatter subtraction, laser drive multipliers were needed to match observed X-ray drives. Those for the picket (0.95), trough (1.0) and second pulse (0.80) were determined by VISAR measurements. The time dependence of the Dante total x-ray flux and its fraction > 1.8 keV reflect the time dependence of the multipliers. A two step drive multiplier for the main pulse can match implosion times, but Dante measurements suggest the drive multiplier must increase late in time. With a single set of time dependent, multi-level multipliers the Dante data are well matched. These same third pulse drive multipliers also match the implosion times and Dante signals for two CH capsule DT. One discrepancy in the calculations is the X-ray flux in the picket. Calculations over-estimate the flux > 1.8 keV by a factor of ~100, while getting the total flux correctly. These harder X-rays cause an expansion of the Be/fuel interface of 2-3 km/s before the arrival of the first shock. VISAR measurements show only 0.2 to 0.3 km/s. The X-ray drive on the DT Be capsule was further degraded by a random decrease of 9% in the total picket flux. This small change caused the capsule fuel to change from an adiabat of 1.8 to 2.3 by mistiming of the first and second shocks. With this shock tuning and adjustments to the calculation, the first NIF Be capsule implosion achieved 29% of calculated yield, comparable to the CH DT capsules of 68% and 21%. Inclusion of a large M1 asymmetry in the DT ice layer and mixing from instability growth may help explain this final degradation. In summary when driven similarly the Be capsules performed like CH capsules. Performance degradation for both seems to be dominated by drive and capsule asymmetries.
△ Less
Submitted 31 January, 2017;
originally announced January 2017.