-
Understanding the gravitational and magnetic environment of a very long baseline atom interferometer
Authors:
Ali Lezeik,
Dorothee Tell,
Klaus Zipfel,
Vishu Gupta,
Étienne Wodey,
Ernst Rasel,
Christian Schubert,
Dennis Schlippert
Abstract:
By utilizing the quadratic dependency of the interferometry phase on time, the Hannover Very Long Baseline Atom Interferometer facility (VLBAI) aims for sub nm/s$^2$ gravity measurement sensitivity. With its 10 m vertical baseline, VLBAI offers promising prospects in testing fundamental physics at the interface between quantum mechanics and general relativity. Here we discuss the challenges impose…
▽ More
By utilizing the quadratic dependency of the interferometry phase on time, the Hannover Very Long Baseline Atom Interferometer facility (VLBAI) aims for sub nm/s$^2$ gravity measurement sensitivity. With its 10 m vertical baseline, VLBAI offers promising prospects in testing fundamental physics at the interface between quantum mechanics and general relativity. Here we discuss the challenges imposed on controlling VLBAI's magnetic and gravitational environment and report on their effect on the device's accuracy. Within the inner 8 m of the magnetic shield, residual magnetic field gradients expect to cause a bias acceleration of only 6$\times$10$^{-14}$ m/s$^2$ while we evaluate the bias shift due to the facility's non-linear gravity gradient to 2.6 nm/s$^2$. The model allows the VLBAI facility to be a reference to other mobile devices for calibration purposes with an uncertainty below the 10 nm/s$^2$ level.
△ Less
Submitted 19 September, 2022;
originally announced September 2022.
-
A robust, high-flux source of laser-cooled ytterbium atoms
Authors:
E. Wodey,
R. J. Rengelink,
C. Meiners,
E. M. Rasel,
D. Schlippert
Abstract:
We present a high-flux source of cold ytterbium atoms that is robust, lightweight and low-maintenance. Our apparatus delivers $10^9$ atoms/s into a 3D magneto-optical trap without requiring water-cooling or high current power supplies. We achieve this by employing a Zeeman slower and a 2D magneto-optical trap fully based on permanent magnets in Halbach configurations. This strategy minimizes mecha…
▽ More
We present a high-flux source of cold ytterbium atoms that is robust, lightweight and low-maintenance. Our apparatus delivers $10^9$ atoms/s into a 3D magneto-optical trap without requiring water-cooling or high current power supplies. We achieve this by employing a Zeeman slower and a 2D magneto-optical trap fully based on permanent magnets in Halbach configurations. This strategy minimizes mechanical complexity, stray magnetic fields, and heat production while requiring little to no maintenance, making it applicable to both embedded systems that seek to minimize electrical power consumption, and large scale experiments to reduce the complexity of their subsystems.
△ Less
Submitted 17 August, 2020;
originally announced August 2020.
-
Gravity field modelling for the Hannover 10m atom interferometer
Authors:
Manuel Schilling,
Étienne Wodey,
Ludger Timmen,
Dorothee Tell,
Klaus H. Zipfel,
Dennis Schlippert,
Christian Schubert,
Ernst M. Rasel,
Jürgen Müller
Abstract:
Absolute gravimeters (AG) are used in geodesy, geophysics, and physics for a wide spectrum of applications. Stable gravimetric measurements over timescales from several days to decades are required to provide relevant insight into geophysical processes. Users of AGs participate in comparisons with a metrological reference in order to monitor the temporal stability of the instruments and determine…
▽ More
Absolute gravimeters (AG) are used in geodesy, geophysics, and physics for a wide spectrum of applications. Stable gravimetric measurements over timescales from several days to decades are required to provide relevant insight into geophysical processes. Users of AGs participate in comparisons with a metrological reference in order to monitor the temporal stability of the instruments and determine the bias to that reference. However, since no measurement standard of higher-order accuracy currently exists, users of AGs participate in key comparisons led by the CIPM. These comparisons provide the reference values of highest accuracy compared to the calibration against a single AG. The construction of stationary, large scale atom interferometers paves the way towards a new measurement standard in absolute gravimetry used as a reference with a potential stability up to 1 nm/s$^2$ at 1 s integration time. At the Leibniz University Hannover, we are currently building such a very long baseline atom interferometer with a 10 m long interaction zone. The knowledge of local gravity and its gradient along and around the baseline is required to establish the instrument's uncertainty budget and enable transfers of gravimetric measurements to nearby devices for comparison and calibration purposes. We therefore established a control network for relative gravimeters and repeatedly measured its connections during the construction of the atom interferometer. We additionally developed a 3D model of the host building to investigate the self-attraction effect and studied the impact of mass changes due to groundwater hydrology on the gravity field around the reference instrument. The gravitational effect from the building 3D model is in excellent agreement with the latest gravimetric measurement campaign which opens the possibility to transfer gravity values with an uncertainty below the 10 nm/s$^2$ level.
△ Less
Submitted 29 November, 2020; v1 submitted 10 March, 2020;
originally announced March 2020.
-
A scalable high-performance magnetic shield for Very Long Baseline Atom Interferometry
Authors:
E. Wodey,
D. Tell,
E. M. Rasel,
D. Schlippert,
R. Baur,
U. Kissling,
B. Kölliker,
M. Lorenz,
M. Marrer,
U. Schläpfer,
M. Widmer,
C. Ufrecht,
S. Stuiber,
P. Fierlinger
Abstract:
We report on the design, construction, and characterization of a 10 m-long high-performance magnetic shield for Very Long Baseline Atom Interferometry (VLBAI). We achieve residual fields below 4 nT and longitudinal inhomogeneities below 2.5 nT/m over 8 m along the longitudinal direction. Our modular design can be extended to longer baselines without compromising the shielding performance. Such a s…
▽ More
We report on the design, construction, and characterization of a 10 m-long high-performance magnetic shield for Very Long Baseline Atom Interferometry (VLBAI). We achieve residual fields below 4 nT and longitudinal inhomogeneities below 2.5 nT/m over 8 m along the longitudinal direction. Our modular design can be extended to longer baselines without compromising the shielding performance. Such a setup constrains biases associated with magnetic field gradients to the sub-pm/$\textrm{s}^2$ level in atomic matterwave accelerometry with rubidium atoms and paves the way towards tests of the universality of free fall with atomic test masses beyond the $10^{-13}$ level.
△ Less
Submitted 3 March, 2020; v1 submitted 27 November, 2019;
originally announced November 2019.
-
Matter Wave Interferometry for Inertial Sensing and Tests of Fundamental Physics
Authors:
D. Schlippert,
C. Meiners,
R. J. Rengelink,
C. Schubert,
D. Tell,
E. Wodey,
K. H. Zipfel,
W. Ertmer,
E. M. Rasel
Abstract:
Very Long Baseline Atom Interferometry (VLBAI) corresponds to ground-based atomic matter-wave interferometry on large scales in space and time, letting the atomic wave functions interfere after free evolution times of several seconds or wave packet separation at the scale of meters. As inertial sensors, e.g., accelerometers, these devices take advantage of the quadratic scaling of the leading orde…
▽ More
Very Long Baseline Atom Interferometry (VLBAI) corresponds to ground-based atomic matter-wave interferometry on large scales in space and time, letting the atomic wave functions interfere after free evolution times of several seconds or wave packet separation at the scale of meters. As inertial sensors, e.g., accelerometers, these devices take advantage of the quadratic scaling of the leading order phase shift with the free evolution time to enhance their sensitivity, giving rise to compelling experiments. With shot noise-limited instabilities better than $10^{-9}$ m/s$^2$ at 1 s at the horizon, VLBAI may compete with state-of-the-art superconducting gravimeters, while providing absolute instead of relative measurements. When operated with several atomic states, isotopes, or species simultaneously, tests of the universality of free fall at a level of parts in $10^{13}$ and beyond are in reach. Finally, the large spatial extent of the interferometer allows one to probe the limits of coherence at macroscopic scales as well as the interplay of quantum mechanics and gravity. We report on the status of the VLBAI facility, its key features, and future prospects in fundamental science.
△ Less
Submitted 18 September, 2019;
originally announced September 2019.
-
Interference of Clocks: A Quantum Twin Paradox
Authors:
Sina Loriani,
Alexander Friedrich,
Christian Ufrecht,
Fabio Di Pumpo,
Stephan Kleinert,
Sven Abend,
Naceur Gaaloul,
Christian Meiners,
Christian Schubert,
Dorothee Tell,
Étienne Wodey,
Magdalena Zych,
Wolfgang Ertmer,
Albert Roura,
Dennis Schlippert,
Wolfgang P. Schleich,
Ernst M. Rasel,
Enno Giese
Abstract:
The phase of matter waves depends on proper time and is therefore susceptible to special-relativistic (kinematic) and gravitational (redshift) time dilation. Hence, it is conceivable that atom interferometers measure general-relativistic time-dilation effects. In contrast to this intuition, we show: (i.) Closed light-pulse interferometers without clock transitions during the pulse sequence are not…
▽ More
The phase of matter waves depends on proper time and is therefore susceptible to special-relativistic (kinematic) and gravitational (redshift) time dilation. Hence, it is conceivable that atom interferometers measure general-relativistic time-dilation effects. In contrast to this intuition, we show: (i.) Closed light-pulse interferometers without clock transitions during the pulse sequence are not sensitive to gravitational time dilation in a linear potential. (ii.) They can constitute a quantum version of the special-relativistic twin paradox. (iii.) Our proposed experimental geometry for a quantum-clock interferometer isolates this effect.
△ Less
Submitted 23 June, 2023; v1 submitted 22 May, 2019;
originally announced May 2019.
-
Optomechanical resonator-enhanced atom interferometry
Authors:
L. L. Richardson,
D. Nath,
A. Rajagopalan,
H. Albers,
C. Meiners,
C. Schubert,
D. Tell,
E. Wodey,
S. Abend,
M. Gersemann,
W. Ertmer,
E. M. Rasel,
D. Schlippert,
M. Mehmet,
L. Kumanchik,
L. Colmenero,
R. Spannagel,
C. Braxmaier,
F. Guzman
Abstract:
Matter-wave interferometry and spectroscopy of optomechanical resonators offer complementary advantages. Interferometry with cold atoms is employed for accurate and long-term stable measurements, yet it is challenged by its dynamic range and cyclic acquisition. Spectroscopy of optomechanical resonators features continuous signals with large dynamic range, however it is generally subject to drifts.…
▽ More
Matter-wave interferometry and spectroscopy of optomechanical resonators offer complementary advantages. Interferometry with cold atoms is employed for accurate and long-term stable measurements, yet it is challenged by its dynamic range and cyclic acquisition. Spectroscopy of optomechanical resonators features continuous signals with large dynamic range, however it is generally subject to drifts. In this work, we combine the advantages of both devices. Measuring the motion of a mirror and matter waves interferometrically with respect to a joint reference allows us to operate an atomic gravimeter in a seismically noisy environment otherwise inhibiting readout of its phase. Our method is applicable to a variety of quantum sensors and shows large potential for improvements of both elements by quantum engineering.
△ Less
Submitted 24 September, 2020; v1 submitted 7 February, 2019;
originally announced February 2019.
-
Ground Tests of Einstein's Equivalence Principle: From Lab-based to 10-m Atomic Fountains
Authors:
D. Schlippert,
H. Albers,
L. L. Richardson,
D. Nath,
H. Heine,
C. Meiners,
É. Wodey,
A. Billon,
J. Hartwig,
C. Schubert,
N. Gaaloul,
W. Ertmer,
E. M. Rasel
Abstract:
To date, no framework combining quantum field theory and general relativity and hence unifying all four fundamental interactions, exists. Violations of the Einstein's equivalence principle (EEP), being the foundation of general relativity, may hold the key to a theory of quantum gravity. The universality of free fall (UFF), which is one of the three pillars of the EEP, has been extensively tested…
▽ More
To date, no framework combining quantum field theory and general relativity and hence unifying all four fundamental interactions, exists. Violations of the Einstein's equivalence principle (EEP), being the foundation of general relativity, may hold the key to a theory of quantum gravity. The universality of free fall (UFF), which is one of the three pillars of the EEP, has been extensively tested with classical bodies. Quantum tests of the UFF, e.g. by exploiting matter wave interferometry, allow for complementary sets of test masses, orders of magnitude larger test mass coherence lengths and investigation of spin-gravity coupling. We review our recent work towards highly sensitive matter wave tests of the UFF on ground. In this scope, the first quantum test of the UFF utilizing two different chemical elements, Rb-87 and K-39, yielding an Eötvös ratio $η_{\,\text{Rb,K}}=(0.3\pm 5.4)\times 10^{-7}$ has been performed. We assess systematic effects currently limiting the measurement at a level of parts in $10^8$ and finally present our strategies to improve the current state-of-the-art with a test comparing the free fall of rubidium and ytterbium in a very long baseline atom interferometry setup. Here, a 10 m baseline combined with a precise control of systematic effects will enable a determination of the Eötvös ratio at a level of parts in $10^{13}$ and beyond, thus reaching and overcoming the performance limit of the best classical tests.
△ Less
Submitted 21 July, 2015;
originally announced July 2015.