Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors
Authors:
M. Lisowska,
R. Aleksan,
Y. Angelis,
S. Aune,
J. Bortfeldt,
F. Brunbauer,
M. Brunoldi,
E. Chatzianagnostou,
J. Datta,
K. Dehmelt,
G. Fanourakis,
S. Ferry,
D. Fiorina,
K. J. Floethner,
M. Gallinaro,
F. Garcia,
I. Giomataris,
K. Gnanvo,
F. J. Iguaz,
D. Janssens,
A. Kallitsopoulou,
M. Kovacic,
B. Kross,
C. C. Lai,
P. Legou
, et al. (33 additional authors not shown)
Abstract:
The PICOSEC Micromegas detector is a precise-timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and a Micromegas amplifying structure, targeting a time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a time resolution below 25 ps, prompting ongoing developments to adapt the concept for…
▽ More
The PICOSEC Micromegas detector is a precise-timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and a Micromegas amplifying structure, targeting a time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a time resolution below 25 ps, prompting ongoing developments to adapt the concept for applications. The achieved performance is being transferred to robust multi-channel detector modules suitable for large-area detection systems requiring excellent timing precision. To enhance the robustness and stability of the PICOSEC Micromegas detector, research on robust carbon-based photocathodes, including Diamond-Like Carbon (DLC) and Boron Carbide (B4C), is pursued. Results from prototypes equipped with DLC and B4C photocathodes exhibited a time resolution of approximately 32 ps and 34.5 ps, respectively. Efforts dedicated to improve detector robustness and stability enhance the feasibility of the PICOSEC Micromegas concept for large experiments, ensuring sustained performance while maintaining excellent timing precision.
△ Less
Submitted 13 July, 2024;
originally announced July 2024.
-
A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors
Authors:
X. Wang,
R. Aleksan,
Y. Angelis,
J. Bortfeldt,
F. Brunbauer,
M. Brunoldi,
E. Chatzianagnostou,
J. Datta,
K. Degmelt,
G. Fanourakis,
D. Fiorina,
K. J. Floethner,
M. Gallinaro,
F. Garcia,
I. Giomataris,
K. Gnanvo,
F. J. Iguaz,
D. Janssens,
A. Kallitsopoulou,
M. Kovacic,
B. Kross,
P. Legou,
M. Lisowska,
J. Liu,
I. Maniatis
, et al. (26 additional authors not shown)
Abstract:
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bomb…
▽ More
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bombardment of the CsI photocathodes, alternative photocathode materials are needed to improve the robustness of PICOSEC MM. Diamond-like Carbon (DLC) film have been introduced as a novel robust photocathode material, which have shown promising results. A batch of DLC photocathodes with different thicknesses were produced and evaluated using ultraviolet light. The quantum efficiency measurements indicate that the optimized thickness of the DLC photocathode is approximately 3 nm. Furthermore, DLC photocathodes show good resistance to ion bombardment in aging test compared to the CsI photocathode. Finally, a PICOSEC MM prototype equipped with DLC photocathodes was tested in muon beams. A time resolution of around 42 ps with a detection efficiency of 97% for 150 GeV/c muons were obtained. These results indicate the great potential of DLC as a photocathode for the PICOSEC MM detector.
△ Less
Submitted 30 July, 2024; v1 submitted 12 June, 2024;
originally announced June 2024.
-
Transforming a rare event search into a not-so-rare event search in real-time with deep learning-based object detection
Authors:
J. Schueler,
H. M. Araújo,
S. N. Balashov,
J. E. Borg,
C. Brew,
F. M. Brunbauer,
C. Cazzaniga,
A. Cottle,
C. D. Frost,
F. Garcia,
D. Hunt,
A. C. Kaboth,
M. Kastriotou,
I. Katsioulas,
A. Khazov,
P. Knights,
H. Kraus,
V. A. Kudryavtsev,
S. Lilley,
A. Lindote,
M. Lisowska,
D. Loomba,
M. I. Lopes,
E. Lopez Asamar,
P. Luna Dapica
, et al. (18 additional authors not shown)
Abstract:
Deep learning-based object detection algorithms enable the simultaneous classification and localization of any number of objects in image data. Many of these algorithms are capable of operating in real-time on high resolution images, attributing to their widespread usage across many fields. We present an end-to-end object detection pipeline designed for real-time rare event searches for the Migdal…
▽ More
Deep learning-based object detection algorithms enable the simultaneous classification and localization of any number of objects in image data. Many of these algorithms are capable of operating in real-time on high resolution images, attributing to their widespread usage across many fields. We present an end-to-end object detection pipeline designed for real-time rare event searches for the Migdal effect, using high-resolution image data from a state-of-the-art scientific CMOS camera in the MIGDAL experiment. The Migdal effect in nuclear scattering, crucial for sub-GeV dark matter searches, has yet to be experimentally confirmed, making its detection a primary goal of the MIGDAL experiment. Our pipeline employs the YOLOv8 object detection algorithm and is trained on real data to enhance the detection efficiency of nuclear and electronic recoils, particularly those exhibiting overlapping tracks that are indicative of the Migdal effect. When deployed online on the MIGDAL readout PC, we demonstrate our pipeline to process and perform the rare event search on 2D image data faster than the peak 120 frame per second acquisition rate of the CMOS camera. Applying these same steps offline, we demonstrate that we can reduce a sample of 20 million camera frames to around 1000 frames while maintaining nearly all signal that YOLOv8 is able to detect, thereby transforming a rare search into a much more manageable search. Our studies highlight the potential of pipelines similar to ours significantly improving the detection capabilities of experiments requiring rapid and precise object identification in high-throughput data environments.
△ Less
Submitted 11 June, 2024;
originally announced June 2024.
-
Spatial resolution improvements with finer-pitch GEMs
Authors:
K. J. Flöthner,
L. Scharenberg,
A. Brask,
F. Brunbauer,
F. Garcia,
D. Janssens,
B. Ketzer,
M. Lisowska,
H. Muller,
E. Oliveri,
G. Orlandini,
D. Pfeiffer,
L. Ropelewski,
J. Samarati,
M. Van Stenis,
R. Veenhof
Abstract:
Gas Electron Multipliers (GEMs) are used in many particle physics experiments, employing their 'standard' configuration with amplification holes of 140 um pitch in a hexagonal pattern. However, the collection of the charge cloud from the primary ionisation electrons from the drift region of the detector into the GEM holes affects the position information from the initial interacting particle. In t…
▽ More
Gas Electron Multipliers (GEMs) are used in many particle physics experiments, employing their 'standard' configuration with amplification holes of 140 um pitch in a hexagonal pattern. However, the collection of the charge cloud from the primary ionisation electrons from the drift region of the detector into the GEM holes affects the position information from the initial interacting particle. In this paper, the results from studies with a triple-GEM detector with an X-Y-strip readout anode are presented. It is demonstrated that GEMs with a finer hole pitch of here 90 um improve the detector's spatial resolution. Within these studies, also the impact of the front-end electronics on the spatial resolution was investigated, which is briefly discussed in the paper.
△ Less
Submitted 9 June, 2024;
originally announced June 2024.
-
Single channel PICOSEC Micromegas detector with improved time resolution
Authors:
A. Utrobicic,
R. Aleksan,
Y. Angelis,
J. Bortfeldt,
F. Brunbauer,
M. Brunoldi,
E. Chatzianagnostou,
J. Datta,
K. Dehmelt,
G. Fanourakis,
D. Fiorina,
K. J. Floethner,
M. Gallinaro,
F. Garcia,
I. Giomataris,
K. Gnanvo,
F. J. Iguaz,
D. Janssens,
A. Kallitsopoulou,
M. Kovacic,
B. Kross,
P. Legou,
M. Lisowska,
J. Liu,
M. Lupberger
, et al. (25 additional authors not shown)
Abstract:
This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving stability, reducing noise, and ensuring signal integrity to optimize timing perfo…
▽ More
This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving stability, reducing noise, and ensuring signal integrity to optimize timing performance. A notable feature is the simple and fast reassembly procedure, facilitating quick replacement of detector internal components that allows for an efficient measurement strategy involving different detector components. The paper also examines the influence of parasitics on the output signal integrity. To validate the design, a prototype assembly and three interchangeable detector boards with varying readout pad diameters were manufactured. The detectors were initially tested in the laboratory environment. Finally, the timing performance of detectors with different pad sizes was verified using a Minimum Ionizing Particle (MIP) beam test. Notably, a record time resolution for a PICOSEC Micromegas detector technology with a CsI photocathode of 12.5$\pm$0.8 ps was achieved with a 10 mm diameter readout pad size detector.
△ Less
Submitted 9 June, 2024;
originally announced June 2024.
-
Characterisation of resistive MPGDs with 2D readout
Authors:
L. Scharenberg,
F. Brunbauer,
H. Danielson,
Z. Fang,
K. J. Flöthner,
F. Garcia,
D. Janssens,
M. Lisowska,
J. Liu,
Y. Lyu,
B. Mehl,
H. Muller,
R. de Oliveira,
E. Oliveri,
G. Orlandini,
D. Pfeiffer,
O. Pizzirusso,
L. Ropelewski,
J. Samarati,
M. Shao,
A. Teixeira,
M. Van Stenis,
R. Veenhof,
Z. Zhang,
Y. Zhou
Abstract:
Micro-Pattern Gaseous Detectors (MPGDs) with resistive anode planes provide intrinsic discharge robustness while maintaining good spatial and time resolutions. Typically read out with 1D strips or pad structures, here the characterisation results of resistive anode plane MPGDs with 2D strip readout are presented. A uRWELL prototype is investigated in view of its use as a reference tracking detecto…
▽ More
Micro-Pattern Gaseous Detectors (MPGDs) with resistive anode planes provide intrinsic discharge robustness while maintaining good spatial and time resolutions. Typically read out with 1D strips or pad structures, here the characterisation results of resistive anode plane MPGDs with 2D strip readout are presented. A uRWELL prototype is investigated in view of its use as a reference tracking detector in a future gaseous beam telescope. A MicroMegas prototype with a fine-pitch mesh (730 line-pairs-per-inch) is investigated, both for comparison and to profit from the better field uniformity and thus the ability to operate the detector more stable at high gains. Furthermore, the measurements are another application of the RD51 VMM3a/SRS electronics.
△ Less
Submitted 6 February, 2024;
originally announced February 2024.
-
Studying signals in particle detectors with resistive elements such as the 2D resistive strip bulk MicroMegas
Authors:
Djunes Janssens,
Florian Brunbauer,
Karl Jonathan Flöthner,
Marta Lisowska,
Hans Muller,
Eraldo Oliveri,
Giorgio Orlandini,
Werner Riegler,
Leszek Ropelewski,
Heinrich Schindler,
Lucian Scharenberg,
Antonija Utrobicic,
Rob Veenhof
Abstract:
As demonstrated by the ATLAS New Small Wheel community with their MicroMegas (MM) design, resistive electrodes are now used in different detector types within the Micro Pattern Gaseous Detector family to improve their robustness or performance. The extended form of the Ramo-Shockley theorem for conductive media has been applied to a 1 M$Ω$/$\Box$ 2D resistive strip bulk MM to calculate the signal'…
▽ More
As demonstrated by the ATLAS New Small Wheel community with their MicroMegas (MM) design, resistive electrodes are now used in different detector types within the Micro Pattern Gaseous Detector family to improve their robustness or performance. The extended form of the Ramo-Shockley theorem for conductive media has been applied to a 1 M$Ω$/$\Box$ 2D resistive strip bulk MM to calculate the signal's spreading over neighbouring channels using an 80 GeV/c muon track. For this geometry, the dynamic weighting potential was obtained numerically using a finite element solver by applying a junction condition and coordinate scaling technique to accurately represent the boundary conditions of a $10\times 10$ cm$^2$ active area. Using test beam measurements, the results of this model will be used to benchmark this microscopic modelling methodology for signal induction in resistive particle detectors.
△ Less
Submitted 4 April, 2023;
originally announced April 2023.
-
A large area 100 channel Picosec Micromegas detector with sub 20 ps time resolution
Authors:
Antonija Utrobicic,
Yannis Angelis,
Stephan Aune,
Jonathan Bortfeldt,
Florian Brunbauer,
Evridiki Chatzianagnostou,
Klaus Dehmelt,
Daniel Desforge,
George Fanourakis,
Karl Jonathan Floethner,
Michele Gallinaro,
Francisco Garcia,
Prakhar Garg,
Ioannis Giomataris,
Kondo Gnanvo,
Thomas Gustavsson,
Francisco Jose Iguaz,
Djunes Janssens,
Alexandra Kallitsopoulou,
Marinko Kovacic,
Philippe Legou,
Marta Lisowska,
Jianbei Liu,
Michael Lupberger,
Simona Malace
, et al. (20 additional authors not shown)
Abstract:
The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplification structure. The first proof of concept single-channel small area prototype was able to achieve time resolution below 25 ps. One of the crucial aspects in the development of the precise timing gaseous detectors applicable in high-energy physics exp…
▽ More
The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplification structure. The first proof of concept single-channel small area prototype was able to achieve time resolution below 25 ps. One of the crucial aspects in the development of the precise timing gaseous detectors applicable in high-energy physics experiments is a modular design that enables large area coverage. The first 19-channel multi-pad prototype with an active area of approximately 10 cm$^2$ suffered from degraded timing resolution due to the non-uniformity of the preamplification gap. A new 100 cm$^2$ detector module with 100 channels based on a rigid hybrid ceramic/FR4 Micromegas board for improved drift gap uniformity was developed. Initial measurements with 80 GeV/c muons showed improvements in timing response over measured pads and a time resolution below 25 ps. More recent measurements with a new thinner drift gap detector module and newly developed RF pulse amplifiers show that the resolution can be enhanced to a level of 17~ps. This work will present the development of the detector from structural simulations, design, and beam test commissioning with a focus on the timing performance of a thinner drift gap detector module in combination with new electronics using an automated timing scan method.
△ Less
Submitted 31 March, 2023;
originally announced April 2023.
-
Towards robust PICOSEC Micromegas precise timing detectors
Authors:
Marta Lisowska,
Yannis Angelis,
Stephan Aune,
Jonathan Bortfeldt,
Florian Brunbauer,
Evridiki Chatzianagnostou,
Klaus Dehmelt,
Daniel Desforge,
George Fanourakis,
Karl Jonathan Floethner,
Michele Gallinaro,
Francisco Garcia,
Prakhar Garg,
Ioannis Giomataris,
Kondo Gnanvo,
Thomas Gustavsson,
Francisco Jose Iguaz,
Djunes Janssens,
Alexandra Kallitsopoulou,
Marinko Kovacic,
Philippe Legou,
Jianbei Liu,
Michael Lupberger,
Simona Malace,
Ioannis Maniatis
, et al. (21 additional authors not shown)
Abstract:
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-channel non-resistive PICOSEC MM prototype with 10x10 cm^2 active area equipped with a Cesium Iodide (CsI) photocathode demonstrated a time resolution below 18 ps. The objective of this work is to improve the PICOSEC MM detec…
▽ More
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-channel non-resistive PICOSEC MM prototype with 10x10 cm^2 active area equipped with a Cesium Iodide (CsI) photocathode demonstrated a time resolution below 18 ps. The objective of this work is to improve the PICOSEC MM detector robustness aspects; i.e. integration of resistive MM and carbon-based photocathodes; while maintaining good time resolution. The PICOSEC MM prototypes have been tested in laboratory conditions and successfully characterised with 150 GeV/c muon beams at the CERN SPS H4 beam line. The excellent timing performance below 20 ps for an individual pad obtained with the 10x10 cm^2 area resistive PICOSEC MM of 20 MOhm/sq showed no significant time resolution degradation as a result of adding a resistive layer. A single-pad prototype equipped with a 12 nm thick Boron Carbide (B4C) photocathode presented a time resolution below 35 ps; opening up new possibilities for detectors with robust photocathodes. The results made the concept more suitable for the experiments in need of robust detectors with good time resolution.
△ Less
Submitted 31 March, 2023;
originally announced March 2023.
-
The novel XYU-GEM to resolve ambiguities
Authors:
K. J. Flöthner,
F. Brunbauer,
S. Ferry,
F. Garcia,
D. Janssens,
B. Ketzer,
M. Lisowska,
H. Muller,
R. de Oliveira,
E. Oliveri,
G. Orlandini,
D. Pfeiffer,
L. Ropelewski,
J. Samarati,
F. Sauli,
L. Scharenberg,
M. van Stenis,
A. Utrobicic,
R. Veenhof
Abstract:
Removing ambiguities within a single stage becomes crucial when one can not use multiple detectors behind each other to resolve them which naturally is the case for neutral radiation. An example would be RICH detectors. Commonly pixilated readout is choosen for this purpose. However, this causes a remarkable increase in quantity of channels and does not scale up well. Therefore, the XYU-GEM was pr…
▽ More
Removing ambiguities within a single stage becomes crucial when one can not use multiple detectors behind each other to resolve them which naturally is the case for neutral radiation. An example would be RICH detectors. Commonly pixilated readout is choosen for this purpose. However, this causes a remarkable increase in quantity of channels and does not scale up well. Therefore, the XYU-GEM was proposed as a three coordinate strip-readout which is combined with a triple GEM detector. The readout complements a common XY readout with an additional projection which is tilted by 45°. The overdetermination due to three projections can be used to resovle ambiguities. Following the detector design will be explained, first measurements discussed to understand the response of the detector and a way to change the charge sharing without changing the manufacturing parameters of the readout.
△ Less
Submitted 31 March, 2023;
originally announced March 2023.
-
Performance of the new RD51 VMM3a/SRS beam telescope---studying MPGDs simultaneously in energy, space and time at high rates
Authors:
L. Scharenberg,
J. Bortfeldt,
F. Brunbauer,
K. Desch,
K. Flöthner,
F. Garcia,
D. Janssens,
M. Lisowska,
H. Muller,
E. Oliveri,
G. Orlandini,
D. Pfeiffer,
L. Ropelewski,
J. Samarati,
D. Sorvisto,
M. van Stenis,
R. Veenhof
Abstract:
The RD51 collaboration maintains a common infrastructure at CERN for its R & D activities, including two beam telescopes for test beam campaigns. Recently, one of the beam telescopes has been equipped and commissioned with new multi-channel and charge-sensitive front-end electronics based on the ATLAS/BNL VMM3a front-end ASIC and the RD51 Scalable Readout System (SRS). This allows to read out the…
▽ More
The RD51 collaboration maintains a common infrastructure at CERN for its R & D activities, including two beam telescopes for test beam campaigns. Recently, one of the beam telescopes has been equipped and commissioned with new multi-channel and charge-sensitive front-end electronics based on the ATLAS/BNL VMM3a front-end ASIC and the RD51 Scalable Readout System (SRS). This allows to read out the detectors at high rates (up to the MHz regime) with electronics time resolutions of the order of 1 ns and the ability to handle different detector types and sizes, due to a larger dynamic range compared to the previous front-end electronics based on the APV25 ASIC. Having studied and improved the beam telescope's performance over the course of three test beam campaigns, the results are presented in this paper.
△ Less
Submitted 16 February, 2023;
originally announced February 2023.
-
Precise timing and recent advancements with segmented anode PICOSEC Micromegas prototypes
Authors:
I. Manthos,
S. Aune,
J. Bortfeldt,
F. Brunbauer,
C. David,
D. Desforge,
G. Fanourakis,
M. Gallinaro,
F. García,
I. Giomataris,
T. Gustavsson,
F. J. Iguaz,
A. Kallitsopoulou,
M. Kebbiri,
K. Kordas,
C. Lampoudis,
P. Legou,
M. Lisowska,
J. Liu,
M. Lupberger,
O. Maillard,
I. Maniatis,
H. Müller,
E. Oliveri,
T. Papaevangelou
, et al. (19 additional authors not shown)
Abstract:
Timing information in current and future accelerator facilities is important for resolving objects (particle tracks, showers, etc.) in extreme large particles multiplicities on the detection systems. The PICOSEC Micromegas detector has demonstrated the ability to time 150\,GeV muons with a sub-25\,ps precision. Driven by detailed simulation studies and a phenomenological model which describes stoc…
▽ More
Timing information in current and future accelerator facilities is important for resolving objects (particle tracks, showers, etc.) in extreme large particles multiplicities on the detection systems. The PICOSEC Micromegas detector has demonstrated the ability to time 150\,GeV muons with a sub-25\,ps precision. Driven by detailed simulation studies and a phenomenological model which describes stochastically the dynamics of the signal formation, new PICOSEC designs were developed that significantly improve the timing performance of the detector. PICOSEC prototypes with reduced drift gap size ($\sim$\SI{119}{\micro\metre}) achieved a resolution of 45\,ps in timing single photons in laser beam tests (in comparison to 76\,ps of the standard PICOSEC detector). Towards large area detectors, multi-pad PICOSEC prototypes with segmented anodes has been developed and studied. Extensive tests in particle beams revealed that the multi-pad PICOSEC technology provides also very precise timing, even when the induced signal is shared among several neighbouring pads. Furthermore, new signal processing algorithms have been developed, which can be applied during data acquisition and provide real time, precise timing.
△ Less
Submitted 22 November, 2022;
originally announced November 2022.
-
Demonstration of Gd-GEM detector design for neutron macromolecular crystallography applications
Authors:
D. Pfeiffer,
F. Brunbauer,
R. Hall-Wilton,
M. Lupberger,
M. Marko,
H. Muller,
E. Oksanen,
E. Oliveri,
L. Ropelewski,
A. Rusu,
J. Samarati,
L. Scharenberg,
M. van Stenis,
P. Thuiner,
R. Veenhof
Abstract:
The European Spallation Source (ESS) in Lund, Sweden will become the world's most powerful thermal neutron source. The Macromolecular Diffractometer (NMX) at the ESS requires three 51.2 x 51.2~cm$^{2}$ detectors with reasonable detection efficiency, sub-mm spatial resolution, a narrow point spread function (PSF) and good time resolution. This work presents measurements with the improved version of…
▽ More
The European Spallation Source (ESS) in Lund, Sweden will become the world's most powerful thermal neutron source. The Macromolecular Diffractometer (NMX) at the ESS requires three 51.2 x 51.2~cm$^{2}$ detectors with reasonable detection efficiency, sub-mm spatial resolution, a narrow point spread function (PSF) and good time resolution. This work presents measurements with the improved version of the NMX detector prototype consisting of a Triple-GEM detector with natural Gd converter and a low material budget readout. The detector was successfully tested at the neutron reactor of the Budapest Neutron Centre (BNC) and at the D16 instrument at the Institut Laue-Langevin (ILL) in Grenoble. The measurements with Cadmium and Gadolinium masks in Budapest demonstrate that the point spread function of the detector lacks long tails that could impede the measurement of diffraction spot intensities. On the D16 instrument at ILL, diffraction spots from Triose phosphate isomerase w/ 2-phosphoglycolate (PGA) inhibitor were measured both in the D16 Helium-3 detector and the Gd-GEM. The comparison between the two detectors show a similar point spread function in both detectors, and the expected efficiency ratio compared to the Helium-3 detector. Both measurements together thus give good indications that the Gd-GEM detector fits the requirements for the NMX instrument at ESS.
△ Less
Submitted 16 March, 2023; v1 submitted 8 November, 2022;
originally announced November 2022.
-
The MIGDAL experiment: Measuring a rare atomic process to aid the search for dark matter
Authors:
H. M. Araújo,
S. N. Balashov,
J. E. Borg,
F. M. Brunbauer,
C. Cazzaniga,
C. D. Frost,
F. Garcia,
A. C. Kaboth,
M. Kastriotou,
I. Katsioulas,
A. Khazov,
H. Kraus,
V. A. Kudryavtsev,
S. Lilley,
A. Lindote,
D. Loomba,
M. I. Lopes,
E. Lopez Asamar,
P. Luna Dapica,
P. A. Majewski,
T. Marley,
C. McCabe,
A. F. Mills,
M. Nakhostin,
T. Neep
, et al. (11 additional authors not shown)
Abstract:
We present the Migdal In Galactic Dark mAtter expLoration (MIGDAL) experiment aiming at the unambiguous observation and study of the so-called Migdal effect induced by fast-neutron scattering. It is hoped that this elusive atomic process can be exploited to enhance the reach of direct dark matter search experiments to lower masses, but it is still lacking experimental confirmation. Our goal is to…
▽ More
We present the Migdal In Galactic Dark mAtter expLoration (MIGDAL) experiment aiming at the unambiguous observation and study of the so-called Migdal effect induced by fast-neutron scattering. It is hoped that this elusive atomic process can be exploited to enhance the reach of direct dark matter search experiments to lower masses, but it is still lacking experimental confirmation. Our goal is to detect the predicted atomic electron emission which is thought to accompany nuclear scattering with low, but calculable, probability, by deploying an Optical Time Projection Chamber filled with a low-pressure gas based on CF$_4$. Initially, pure CF$_4$ will be used, and then in mixtures containing other elements employed by leading dark matter search technologies -- including noble species, plus Si and Ge. High resolution track images generated by a Gas Electron Multiplier stack, together with timing information from scintillation and ionisation readout, will be used for 3D reconstruction of the characteristic event topology expected for this process -- an arrangement of two tracks sharing a common vertex, with one belonging to a Migdal electron and the other to a nuclear recoil. Different energy-loss rate distributions along both tracks will be used as a powerful discrimination tool against background events. In this article we present the design of the experiment, informed by extensive particle and track simulations and detailed estimations of signal and background rates. In pure CF$_4$ we expect to observe 8.9 (29.3) Migdal events per calendar day of exposure to an intense D-D (D-T) neutron generator beam at the NILE facility located at the Rutherford Appleton Laboratory (UK). With our nominal assumptions, 5$σ$ median discovery significance can be achieved in under one day with either generator.
△ Less
Submitted 5 May, 2023; v1 submitted 17 July, 2022;
originally announced July 2022.
-
Snowmass 2021 White Paper Instrumentation Frontier 05 -- White Paper 1: MPGDs: Recent advances and current R&D
Authors:
K. Dehmelt,
M. Della Pietra,
H. Muller,
S. E. Tzamarias,
A. White,
S. White,
Z. Zhang,
M. Alviggi,
I. Angelis,
S. Aune,
J. Bortfeldt,
M. Bregant,
F. Brunbauer,
M. T. Camerlingo,
V. Canale,
V. D'Amico,
D. Desforge,
C. Di Donato,
R. Di Nardo,
G. Fanourakis,
K. J. Floethner,
M. Gallinaro,
F. Garcia,
I. Giomataris,
K. Gnanvo
, et al. (45 additional authors not shown)
Abstract:
This paper will review the origins, development, and examples of new versions of Micro-Pattern Gas Detectors. The goal for MPGD development was the creation of detectors that could cost-effectively cover large areas while offering excellent position and timing resolution, and the ability to operate at high incident particle rates. The early MPGD developments culminated in the formation of the RD51…
▽ More
This paper will review the origins, development, and examples of new versions of Micro-Pattern Gas Detectors. The goal for MPGD development was the creation of detectors that could cost-effectively cover large areas while offering excellent position and timing resolution, and the ability to operate at high incident particle rates. The early MPGD developments culminated in the formation of the RD51 collaboration which has become the critical organization for the promotion of MPGDs and all aspects of their production, characterization, simulation, and uses in an expanding array of experimental configurations. For the Snowmass 2021 study, a number of Letters of Interest were received that illustrate ongoing developments and expansion of the use of MPGDs. In this paper, we highlight high precision timing, high rate application, trigger capability expansion of the SRS readout system, and a structure designed for low ion backflow.
△ Less
Submitted 19 March, 2022; v1 submitted 12 March, 2022;
originally announced March 2022.
-
Recoil imaging for directional detection of dark matter, neutrinos, and physics beyond the Standard Model
Authors:
C. A. J. O'Hare,
D. Loomba,
K. Altenmüller,
H. Álvarez-Pol,
F. D. Amaro,
H. M. Araújo,
D. Aristizabal Sierra,
J. Asaadi,
D. Attié,
S. Aune,
C. Awe,
Y. Ayyad,
E. Baracchini,
P. Barbeau,
J. B. R. Battat,
N. F. Bell,
B. Biasuzzi,
L. J. Bignell,
C. Boehm,
I. Bolognino,
F. M. Brunbauer,
M. Caamaño,
C. Cabo,
D. Caratelli,
J. M. Carmona
, et al. (142 additional authors not shown)
Abstract:
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detect…
▽ More
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detectors. This white paper outlines the physics case for recoil imaging, and puts forward a decadal plan to advance towards the directional detection of low-energy recoils with sensitivity and resolution close to fundamental performance limits. The science case covered includes: the discovery of dark matter into the neutrino fog, directional detection of sub-MeV solar neutrinos, the precision study of coherent-elastic neutrino-nucleus scattering, the detection of solar axions, the measurement of the Migdal effect, X-ray polarimetry, and several other applied physics goals. We also outline the R&D programs necessary to test concepts that are crucial to advance detector performance towards their fundamental limit: single primary electron sensitivity with full 3D spatial resolution at the $\sim$100 micron-scale. These advancements include: the use of negative ion drift, electron counting with high-definition electronic readout, time projection chambers with optical readout, and the possibility for nuclear recoil tracking in high-density gases such as argon. We also discuss the readout and electronics systems needed to scale-up such detectors to the ton-scale and beyond.
△ Less
Submitted 17 July, 2022; v1 submitted 11 March, 2022;
originally announced March 2022.
-
Rate-capability of the VMM3a Front End in the RD51 Scalable Readout System
Authors:
D. Pfeiffer,
L. Scharenberg,
P. Schwäbig,
S. Alcock,
F. Brunbauer,
M. J. Christensen,
K. Desch,
K. Flöthner,
F. Garcia,
R. Hall-Wilton,
M. Hracek,
G. Iakovidis,
D. Janssens,
J. Kaminski,
M. Lupberger,
H. Muller,
E. Oliveri,
L. Ropelewski,
A. Rusu,
J. Samarati,
M. van Stenis,
A. Utrobicic,
R. Veenhof
Abstract:
The VMM3a is an Application Specific Integrated Circuit (ASIC), specifically developed for the readout of gaseous detectors. Originally developed within the ATLAS New Small Wheel (NSW) upgrade, it has been successfully integrated into the Scalable Readout System (SRS) of the RD51 collaboration. This allows, to use the VMM3a also in small laboratory set-ups and mid-scale experiments, which make use…
▽ More
The VMM3a is an Application Specific Integrated Circuit (ASIC), specifically developed for the readout of gaseous detectors. Originally developed within the ATLAS New Small Wheel (NSW) upgrade, it has been successfully integrated into the Scalable Readout System (SRS) of the RD51 collaboration. This allows, to use the VMM3a also in small laboratory set-ups and mid-scale experiments, which make use of Micro-Pattern Gaseous Detectors (MPGDs). As part of the integration of the VMM3a into the SRS, the readout and data transfer scheme was optimised to reach a high rate-capability of the entire readout system and profit from the VMM3a's high single-channel rate-capability of 3.6 Mhits/s. The optimisation focused mainly on the handling of the data output stream of the VMM3a, but also on the development of a trigger-logic between the front-end cards and the DAQ computer. In this article, two firmware implementations of the non-ATLAS continuous readout mode are presented, as well as the implementation of the trigger-logic. Afterwards, a short overview on X-ray imaging results is presented, to illustrate the high rate-capability rom an application point-of-view.
△ Less
Submitted 2 February, 2022; v1 submitted 21 September, 2021;
originally announced September 2021.
-
Nuclear dependence of light neutral meson production in p-A collisions at 400 GeV with NA60
Authors:
R. Arnaldi,
K. Banicz,
K. Borer,
J. Castor,
B. Chaurand,
W. Chen,
C. Cicalò,
A. Colla,
P. Cortese,
S. Damjanovic,
A. David,
A. De Falco,
A. Devaux,
L. Ducroux,
H. En'yo,
J. Fargeix,
A. Ferretti,
M. Floris,
A. Förster,
P. Force,
N. Guettet,
A. Guichard,
H. Gulkanian,
J. M. Heuser,
P. Jarron
, et al. (29 additional authors not shown)
Abstract:
The NA60 experiment has studied low-mass muon pair production in proton-nucleus collisions with a system of Be, Cu, In, W, Pb and U targets, using a 400 GeV proton beam at the CERN SPS. The transverse momentum spectra of the $ρ/ω$ and $φ$ mesons are measured in the full $p_\mathrm{T}$ range accessible, from $p_\mathrm{T} = 0$ up to 2 GeV/$c$. The nuclear dependence of the production cross sections…
▽ More
The NA60 experiment has studied low-mass muon pair production in proton-nucleus collisions with a system of Be, Cu, In, W, Pb and U targets, using a 400 GeV proton beam at the CERN SPS. The transverse momentum spectra of the $ρ/ω$ and $φ$ mesons are measured in the full $p_\mathrm{T}$ range accessible, from $p_\mathrm{T} = 0$ up to 2 GeV/$c$. The nuclear dependence of the production cross sections of the $η$, $ω$ and $φ$ mesons has been found to be consistent with the power law $σ_\mathrm{pA} \propto \mathrm{A}^α$, with the $α$ parameter increasing as a function of $p_\mathrm{T}$ for all the particles, and an approximate hierarchy $α_η\approx α_φ> α_ω$. The cross section ratios $σ_η/σ_ω$, $σ_ρ/σ_ω$ and $σ_φ/σ_ω$ have been studied as a function of the size A of the production target, and an increase of the $η$ and $φ$ yields relative to the $ω$ is observed from p-Be to p-U collisions.
△ Less
Submitted 28 December, 2020;
originally announced December 2020.
-
Timing performance of a multi-pad PICOSEC-Micromegas detector prototype
Authors:
S. Aune,
J. Bortfeldt,
F. Brunbauer,
C. David,
D. Desforge,
G. Fanourakis,
M. Gallinaro,
F. García,
I. Giomataris,
T. Gustavsson,
F. J. Iguaz,
M. Kebbiri,
K. Kordas,
C. Lampoudis,
P. Legou,
M. Lisowska,
J. Liu,
M. Lupberger,
O. Maillard,
I. Manthos,
H. Müller,
E. Oliveri,
T. Papaevangelou,
K. Paraschou,
M. Pomorski
, et al. (17 additional authors not shown)
Abstract:
The multi-pad PICOSEC-Micromegas is an improved detector prototype with a segmented anode, consisting of 19 hexagonal pads. Detailed studies are performed with data collected in a muon beam over four representative pads. We demonstrate that such a device, scalable to a larger area, provides excellent time resolution and detection efficiency. As expected from earlier single-cell device studies, we…
▽ More
The multi-pad PICOSEC-Micromegas is an improved detector prototype with a segmented anode, consisting of 19 hexagonal pads. Detailed studies are performed with data collected in a muon beam over four representative pads. We demonstrate that such a device, scalable to a larger area, provides excellent time resolution and detection efficiency. As expected from earlier single-cell device studies, we measure a time resolution of approximately 25 picoseconds for charged particles hitting near the anode pad centers, and up to 30 picoseconds at the pad edges. Here, we study in detail the effect of drift gap thickness non-uniformity on the timing performance and evaluate impact position based corrections to obtain a uniform timing response over the full detector coverage.
△ Less
Submitted 28 January, 2021; v1 submitted 1 December, 2020;
originally announced December 2020.
-
Optical Readout Studies of the Thick-COBRA Gaseous Detector
Authors:
F. Garcia,
F. M. Brunbauer,
M. Lisowska,
H. Müller,
E. Oliveri,
D. Pfeiffer,
L. Ropelewski,
J. Samarati,
F. Sauli,
L. Scharenberg,
A. L. M. Silva,
M. van Stenis,
R. Veenhof,
J. F. C. A. Veloso
Abstract:
The performance of a Thick-COBRA (THCOBRA) gaseous detector is studied using an optical readout technique. The operation principle of this device is described, highlighting its operation in a gas mixture of Ar/CF4 (80/20%) for visible scintillation light emission. The contributions to the total gain from the holes and the anode strips as a function of the applied bias voltage were visualized. The…
▽ More
The performance of a Thick-COBRA (THCOBRA) gaseous detector is studied using an optical readout technique. The operation principle of this device is described, highlighting its operation in a gas mixture of Ar/CF4 (80/20%) for visible scintillation light emission. The contributions to the total gain from the holes and the anode strips as a function of the applied bias voltage were visualized. The preservation of spatial information from the initial ionizations was demonstrated by analyzing the light emission from 5.9keV X-rays of an 55Fe source. The observed non-uniformity of the scintillation light from the holes supports the claim of a space localization accuracy better than the pitch of the holes. The acquired images were used to identify weak points and sources of instabilities in view of the development of new optimized structures.
△ Less
Submitted 24 July, 2020;
originally announced July 2020.
-
Electron transparency of a Micromegas mesh
Authors:
K. Nikolopoulos,
P. Bhattacharya,
V. Chernyatin,
R. Veenhof
Abstract:
Measurements of the electron transparency of a Micromegas mesh are compared to simulations. The flux conservation argument is shown to lead to inaccurate estimates of the transparency, the importance of accurate geometric modelling of the mesh is discussed and the effect of the dipole moment of the mesh is demonstrated. This study provides a validation of the microscopic simulation methods specifi…
▽ More
Measurements of the electron transparency of a Micromegas mesh are compared to simulations. The flux conservation argument is shown to lead to inaccurate estimates of the transparency, the importance of accurate geometric modelling of the mesh is discussed and the effect of the dipole moment of the mesh is demonstrated. This study provides a validation of the microscopic simulation methods specifically developed for micropattern devices where the characteristic dimensions are of the same order of magnitude as the electron mean free path in the gas.
△ Less
Submitted 3 May, 2020;
originally announced May 2020.
-
Timing Performance of a Micro-Channel-Plate Photomultiplier Tube
Authors:
Jonathan Bortfeldt,
Florian Brunbauer,
Claude David,
Daniel Desforge,
Georgios Fanourakis,
Michele Gallinaro,
Francisco Garcia,
Ioannis Giomataris,
Thomas Gustavsson,
Claude Guyot,
Francisco Jose Iguaz,
Mariam Kebbiri,
Kostas Kordas,
Philippe Legou,
Jianbei Liu,
Michael Lupberger,
Ioannis Manthos,
Hans Müller,
Vasileios Niaouris,
Eraldo Oliveri,
Thomas Papaevangelou,
Konstantinos Paraschou,
Michal Pomorski,
Filippo Resnati,
Leszek Ropelewski
, et al. (14 additional authors not shown)
Abstract:
The spatial dependence of the timing performance of the R3809U-50 Micro-Channel-Plate PMT (MCP-PMT) by Hamamatsu was studied in high energy muon beams. Particle position information is provided by a GEM tracker telescope, while timing is measured relative to a second MCP-PMT, identical in construction. In the inner part of the circular active area (radius r$<$5.5\,mm) the time resolution of the tw…
▽ More
The spatial dependence of the timing performance of the R3809U-50 Micro-Channel-Plate PMT (MCP-PMT) by Hamamatsu was studied in high energy muon beams. Particle position information is provided by a GEM tracker telescope, while timing is measured relative to a second MCP-PMT, identical in construction. In the inner part of the circular active area (radius r$<$5.5\,mm) the time resolution of the two MCP-PMTs combined is better than 10~ps. The signal amplitude decreases in the outer region due to less light reaching the photocathode, resulting in a worse time resolution. The observed radial dependence is in quantitative agreement with a dedicated simulation. With this characterization, the suitability of MCP-PMTs as $\text{t}_\text{0}$ reference detectors has been validated.
△ Less
Submitted 14 February, 2020; v1 submitted 27 September, 2019;
originally announced September 2019.
-
MPGD simulation in negative-ion gas for direction-sensitive dark matter searches
Authors:
Hirohisa Ishiura,
Rob Veenhof,
Kentaro Miuchi,
Ikeda Tomonori
Abstract:
Negative-ion time projection chambers (NITPCs) provide the absolute z-position from the arrival-times' difference of several species of negative-ions. This is a strong background reduction method for rare event searches, such as direct dark mater searches. The characteristics of micro pattern gaseous detectors (MPGDs) in negative-ion gas were studied by both experiments and simulations to develop…
▽ More
Negative-ion time projection chambers (NITPCs) provide the absolute z-position from the arrival-times' difference of several species of negative-ions. This is a strong background reduction method for rare event searches, such as direct dark mater searches. The characteristics of micro pattern gaseous detectors (MPGDs) in negative-ion gas were studied by both experiments and simulations to develop an NITPC for dark matter search experiments. An MPGD simulation method for the negative-ion gas with Garfield++, which has not yet been established, was developed. We present herein the MPGD simulation results in negative-ion gas, $\mathrm{SF_{6}}$ gas, together with the experimental results, such as gain, energy resolution, and signal creation from the MPGD for future NITPC optimization.
△ Less
Submitted 30 July, 2019;
originally announced July 2019.
-
Modeling the Timing Characteristics of the PICOSEC Micromegas Detector
Authors:
J. Bortfeldt,
F. Brunbauer,
C. David,
D. Desforge,
G. Fanourakis,
M. Gallinaro,
F. García,
I. Giomataris,
T. Gustavsson,
F. J. Iguaz,
M. Kebbiri,
K. Kordas,
C. Lampoudis,
P. Legou,
M. Lisowska,
J. Liu,
M. Lupberger,
O. Maillard,
I. Manthos,
H. Müller,
V. Niaouris,
E. Oliveri,
T . Papaevangelou,
K. Paraschou,
M. Pomorski
, et al. (16 additional authors not shown)
Abstract:
The PICOSEC Micromegas detector can time the arrival of Minimum Ionizing Particles with a sub-25 ps precision. A very good timing resolution in detecting single photons is also demonstrated in laser beams. The PICOSEC timing resolution is determined mainly by the drift field. The arrival time of the signal and the timing resolution vary with the size of the pulse amplitude. Detailed simulations ba…
▽ More
The PICOSEC Micromegas detector can time the arrival of Minimum Ionizing Particles with a sub-25 ps precision. A very good timing resolution in detecting single photons is also demonstrated in laser beams. The PICOSEC timing resolution is determined mainly by the drift field. The arrival time of the signal and the timing resolution vary with the size of the pulse amplitude. Detailed simulations based on GARFIELD++ reproduce the experimental PICOSEC timing characteristics. This agreement is exploited to identify the microscopic physical variables, which determine the observed timing properties. In these studies, several counter-intuitive observations are made for the behavior of such microscopic variables. In order to gain insight on the main physical mechanisms causing the observed behavior, a phenomenological model is constructed and presented. The model is based on a simple mechanism of "time-gain per interaction" and it employs a statistical description of the avalanche evolution. It describes quantitatively the dynamical and statistical properties of the microscopic quantities, which determine the PICOSEC timing characteristics, in excellent agreement with the simulations. In parallel, it offers phenomenological explanations for the behavior of these microscopic variables. The formulae expressing this model can be used as a tool for fast and reliable predictions, provided that the input parameter values (e.g. drift velocities) are known for the considered operating conditions.
△ Less
Submitted 2 December, 2020; v1 submitted 30 January, 2019;
originally announced January 2019.
-
Precise Charged Particle Timing with the PICOSEC Detector
Authors:
J. Bortfeldt,
F. Brunbauer,
C. David,
D. Desforge,
G. Fanourakis,
J. Franchi,
M. Gallinaro,
F. García,
I. Giomataris,
T. Gustavsson,
C. Guyot,
F. J. Iguaz,
M. Kebbiri,
K. Kordas,
P. Legou,
J. Liu,
M. Lupberger,
O. Maillard,
I. Manthos,
H. Müller,
V. Niaouris,
E. Oliveri,
T. Papaevangelou,
K. Paraschou,
M. Pomorski
, et al. (16 additional authors not shown)
Abstract:
The experimental requirements in near future accelerators (e.g. High Luminosity-LHC) has stimulated intense interest in development of detectors with high precision timing capabilities. With this as a goal, a new detection concept called PICOSEC, which is based to a "two-stage" MicroMegas detector coupled to a Cherenkov radiator equipped with a photocathode has been developed. Results obtained wit…
▽ More
The experimental requirements in near future accelerators (e.g. High Luminosity-LHC) has stimulated intense interest in development of detectors with high precision timing capabilities. With this as a goal, a new detection concept called PICOSEC, which is based to a "two-stage" MicroMegas detector coupled to a Cherenkov radiator equipped with a photocathode has been developed. Results obtained with this new detector yield a time resolution of 24\,ps for 150\,GeV muons and 76\,ps for single photoelectrons. In this paper we will report on the performance of the PICOSEC in test beams, as well as simulation studies and modelling of its timing characteristics.
△ Less
Submitted 10 January, 2019;
originally announced January 2019.
-
Interfacing Geant4, Garfield++ and Degrad for the Simulation of Gaseous Detectors
Authors:
Dorothea Pfeiffer,
Lennert De Keukeleere,
Carlos Azevedo,
Francesca Belloni,
Stephen Biagi,
Vladimir Grichine,
Leendert Hayen,
Andrei R. Hanu,
Ivana Hřivnáčová,
Vladimir Ivanchenko,
Vladyslav Krylov,
Heinrich Schindler,
Rob Veenhof
Abstract:
For several years, attempts have been made to interface Geant4 and other software packages with the aim of simulating the complete response of a gaseous particle detector. In such a simulation, Geant4 is always responsible for the primary particle generation and the interactions that occur in the non-gaseous detector material. Garfield++ on the other hand always deals with the drift of ions and el…
▽ More
For several years, attempts have been made to interface Geant4 and other software packages with the aim of simulating the complete response of a gaseous particle detector. In such a simulation, Geant4 is always responsible for the primary particle generation and the interactions that occur in the non-gaseous detector material. Garfield++ on the other hand always deals with the drift of ions and electrons, amplification via electron avalanches and finally signal generation. For the ionizing interaction of particles with the gas, different options and physics models exist. The present paper focuses on how to use Geant4, Garfield++ (including its Heed and SRIM interfaces) and Degrad to create the ionization electron-ion pairs in the gas. Software-wise, the proposed idea is to use the Geant4 physics parameterization feature, and to implement a Garfield++ or Degrad based detector simulation as an external model. With a Degrad model, detailed simulations of the X-ray interaction in gaseous detectors, including shell absorption by photoelectric effect, subsequent Auger cascade, shake-off and fluorescence emission, become possible. A simple Garfield++ model can be used for photons (Heed), heavy ions (SRIM) and relativistic charged particles or MIPs (Heed). For non-relativistic charged particles, more effort is required, and a combined Geant4/Garfield++ model must be used. This model, the Geant4/Heed PAI model interface, uses the Geant4 PAI model in conjunction with the Heed PAI model. Parameters, such as the lower production cut of the Geant4 PAI model and the lowest electron energy limit have to be set correctly. The paper demonstrates how to determine these parameters for certain values of the W parameter and Fano factor of the gas mixture. The simulation results of this Geant4/Heed PAI model interface are then verified against the results obtained with the stand-alone software packages.
△ Less
Submitted 26 February, 2019; v1 submitted 15 June, 2018;
originally announced June 2018.
-
Charged particle timing at sub-25 picosecond precision: the PICOSEC detection concept
Authors:
F. J. Iguaz,
J. Bortfeldt,
F. Brunbauer,
C. David,
D. Desforge,
G. Fanourakis,
J. Franchi,
M. Gallinaro,
F. García,
I. Giomataris,
D. González-Díaz,
T. Gustavsson,
C. Guyot,
M. Kebbiri,
P. Legou,
J. Liu,
M. Lupberger,
O. Maillard,
I. Manthos,
H. Müller,
V. Niaouris,
E. Oliveri,
T. Papaevangelou,
K. Paraschou,
M. Pomorski
, et al. (16 additional authors not shown)
Abstract:
The PICOSEC detection concept consists in a "two-stage" Micromegas detector coupled to a Cherenkov radiator and equipped with a photocathode. A proof of concept has already been tested: a single-photoelectron response of 76 ps has been measured with a femtosecond UV laser at CEA/IRAMIS, while a time resolution of 24 ps with a mean yield of 10.4 photoelectrons has been measured for 150 GeV muons at…
▽ More
The PICOSEC detection concept consists in a "two-stage" Micromegas detector coupled to a Cherenkov radiator and equipped with a photocathode. A proof of concept has already been tested: a single-photoelectron response of 76 ps has been measured with a femtosecond UV laser at CEA/IRAMIS, while a time resolution of 24 ps with a mean yield of 10.4 photoelectrons has been measured for 150 GeV muons at the CERN SPS H4 secondary line. This work will present the main results of this prototype and the performance of the different detector configurations tested in 2016-18 beam campaigns: readouts (bulk, resistive, multipad) and photocathodes (metallic+CsI, pure metallic, diamond). Finally, the prospects for building a demonstrator based on PICOSEC detection concept for future experiments will be discussed. In particular, the scaling strategies for a large area coverage with a multichannel readout plane, the R\&D on solid converters for building a robust photocathode and the different resistive configurations for a robust readout.
△ Less
Submitted 4 August, 2018; v1 submitted 12 June, 2018;
originally announced June 2018.
-
PICOSEC: Charged particle timing at sub-25 picosecond precision with a Micromegas based detector
Authors:
J. Bortfeldt,
F. Brunbauer,
C. David,
D. Desforge,
G. Fanourakis,
J. Franchi,
M. Gallinaro,
I. Giomataris,
D. González-Díaz,
T. Gustavsson,
C. Guyot,
F. J. Iguaz,
M. Kebbiri,
P. Legou,
J. Liu,
M. Lupberger,
O. Maillard,
I. Manthos,
H. Müller,
V. Niaouris,
E. Oliveri,
T. Papaevangelou,
K. Paraschou,
M. Pomorski,
B. Qi
, et al. (15 additional authors not shown)
Abstract:
The prospect of pileup induced backgrounds at the High Luminosity LHC (HL-LHC) has stimulated intense interest in developing technologies for charged particle detection with accurate timing at high rates. The required accuracy follows directly from the nominal interaction distribution within a bunch crossing ($σ_z\sim5$ cm, $σ_t\sim170$ ps). A time resolution of the order of 20-30 ps would lead to…
▽ More
The prospect of pileup induced backgrounds at the High Luminosity LHC (HL-LHC) has stimulated intense interest in developing technologies for charged particle detection with accurate timing at high rates. The required accuracy follows directly from the nominal interaction distribution within a bunch crossing ($σ_z\sim5$ cm, $σ_t\sim170$ ps). A time resolution of the order of 20-30 ps would lead to significant reduction of these backgrounds. With this goal, we present a new detection concept called PICOSEC, which is based on a "two-stage" Micromegas detector coupled to a Cherenkov radiator and equipped with a photocathode. First results obtained with this new detector yield a time resolution of 24 ps for 150 GeV muons, and 76 ps for single photoelectrons.
△ Less
Submitted 14 March, 2018; v1 submitted 14 December, 2017;
originally announced December 2017.
-
Simulation of gain stability of THGEM gas-avalanche particle detectors
Authors:
P. M. M. Correia,
M. Pitt,
C. D. R. Azevedo,
A. Breskin,
S. Bressler,
C. A. B. Oliveira,
A. L. M. Silva,
R. Veenhof,
J. F. C. A. Veloso
Abstract:
Charging-up processes affecting gain stability in Thick Gas Electron Multipliers (THGEM) were studied with a dedicated simulation toolkit. Integrated with Garfield++, it provides an effective platform for systematic phenomenological studies of charging-up processes in MPGD detectors. We describe the simulation tool and the fine-tuning of the step-size required for the algorithm convergence, in rel…
▽ More
Charging-up processes affecting gain stability in Thick Gas Electron Multipliers (THGEM) were studied with a dedicated simulation toolkit. Integrated with Garfield++, it provides an effective platform for systematic phenomenological studies of charging-up processes in MPGD detectors. We describe the simulation tool and the fine-tuning of the step-size required for the algorithm convergence, in relation to physical parameters. Simulation results of gain stability over time in THGEM detectors are presented, exploring the role of electrode-thickness and applied voltage on its evolution. The results show that the total amount of irradiated charge through electrode's hole needed for reaching gain stabilization is in the range of tens to hundreds of pC, depending on the detector geometry and operational voltage. These results are in agreement with experimental observations presented previously.
△ Less
Submitted 6 November, 2017;
originally announced November 2017.
-
Fast Timing for High-Rate Environments with Micromegas
Authors:
Thomas Papaevangelou,
Daniel Desforge,
Esther Ferrer-Ribas,
Ioannis Giomataris,
Cyprien Godinot,
Diego Gonzalez Diaz,
Thomas Gustavsson,
Mariam Kebbiri,
Eraldo Oliveri,
Filippo Resnati,
Leszek Ropelewski,
Georgios Tsiledakis,
Rob Veenhof,
Sebastian White
Abstract:
The current state of the art in fast timing resolution for existing experiments is of the order of 100 ps on the time of arrival of both charged particles and electromagnetic showers. Current R&D on charged particle timing is approaching the level of 10 ps but is not primarily directed at sustained performance at high rates and under high radiation (as would be needed for HL-LHC pileup mitigation)…
▽ More
The current state of the art in fast timing resolution for existing experiments is of the order of 100 ps on the time of arrival of both charged particles and electromagnetic showers. Current R&D on charged particle timing is approaching the level of 10 ps but is not primarily directed at sustained performance at high rates and under high radiation (as would be needed for HL-LHC pileup mitigation). We demonstrate a Micromegas based solution to reach this level of performance. The Micromegas acts as a photomultiplier coupled to a Cerenkov-radiator front window, which produces sufficient UV photons to convert the ~100 ps single-photoelectron jitter into a timing response of the order of 10-20 ps per incident charged particle. A prototype has been built in order to demonstrate this performance. The first laboratory tests with a pico-second laser have shown a time resolution of the order of 27 ps for ~50 primary photoelectrons, using a bulk Micromegas readout.
△ Less
Submitted 12 January, 2016; v1 submitted 1 January, 2016;
originally announced January 2016.
-
Charge Transfer Properties Through Graphene for Applications in Gaseous Detectors
Authors:
S. Franchino,
D. Gonzalez-Diaz,
R. Hall-Wilton,
R. B. Jackman,
H. Muller,
T. T. Nguyen,
R. de Oliveira,
E. Oliveri,
D. Pfeiffer,
F. Resnati,
L. Ropelewski,
J. Smith,
M. van Stenis,
C. Streli,
P. Thuiner,
R. Veenhof
Abstract:
Graphene is a single layer of carbon atoms arranged in a honeycomb lattice with remarkable mechanical and electrical properties. Regarded as the thinnest and narrowest conductive mesh, it has drastically different transmission behaviours when bombarded with electrons and ions in vacuum. This property, if confirmed in gas, may be a definitive solution for the ion back-flow problem in gaseous detect…
▽ More
Graphene is a single layer of carbon atoms arranged in a honeycomb lattice with remarkable mechanical and electrical properties. Regarded as the thinnest and narrowest conductive mesh, it has drastically different transmission behaviours when bombarded with electrons and ions in vacuum. This property, if confirmed in gas, may be a definitive solution for the ion back-flow problem in gaseous detectors. In order to ascertain this aspect, graphene layers of dimensions of about 2x2cm$^2$, grown on a copper substrate, are transferred onto a flat metal surface with holes, so that the graphene layer is freely suspended. The graphene and the support are installed into a gaseous detector equipped with a triple Gaseous Electron Multiplier (GEM), and the transparency properties to electrons and ions are studied in gas as a function of the electric fields. The techniques to produce the graphene samples are described, and we report on preliminary tests of graphene-coated GEMs.
△ Less
Submitted 16 December, 2015;
originally announced December 2015.
-
Effects of High Charge Densities in Multi-GEM Detectors
Authors:
S. Franchino,
D. Gonzalez Diaz,
R. Hall-Wilton,
H. Muller,
E. Oliveri,
D. Pfeiffer,
F. Resnati,
L. Ropelewski,
M. Van Stenis,
C. Streli,
P. Thuiner,
R. Veenhof
Abstract:
A comprehensive study, supported by systematic measurements and numerical computations, of the intrinsic limits of multi-GEM detectors when exposed to very high particle fluxes or operated at very large gains is presented. The observed variations of the gain, of the ion back-flow, and of the pulse height spectra are explained in terms of the effects of the spatial distribution of positive ions and…
▽ More
A comprehensive study, supported by systematic measurements and numerical computations, of the intrinsic limits of multi-GEM detectors when exposed to very high particle fluxes or operated at very large gains is presented. The observed variations of the gain, of the ion back-flow, and of the pulse height spectra are explained in terms of the effects of the spatial distribution of positive ions and their movement throughout the amplification structure. The intrinsic dynamic character of the processes involved imposes the use of a non-standard simulation tool for the interpretation of the measurements. Computations done with a Finite Element Analysis software reproduce the observed behaviour of the detector. The impact of this detailed description of the detector in extreme conditions is multiple: it clarifies some detector behaviours already observed, it helps in defining intrinsic limits of the GEM technology, and it suggests ways to extend them.
△ Less
Submitted 15 December, 2015;
originally announced December 2015.
-
Modelling the behaviour of microbulk Micromegas in Xenon/trimethylamine gas
Authors:
E. Ruiz-Choliz,
D. Gonzalez-Diaz,
A. Diago,
J. Castel,
T. Dafni,
D. C. Herrera,
F. J. Iguaz,
I. G. Irastorza,
G. Luzon,
H. Mirallas,
O. Sahin,
R. Veenhof
Abstract:
We model the response of a state of the art micro-hole single-stage charge amplication device (`microbulk' Micromegas) in a gaseous atmosphere consisting of Xenon/trimethylamine at various concentrations and pressures. The amplifying structure, made with photo-lithographic techniques similar to those followed in the fabrication of gas electron multipliers (GEMs), consisted of a 100 um-side equilat…
▽ More
We model the response of a state of the art micro-hole single-stage charge amplication device (`microbulk' Micromegas) in a gaseous atmosphere consisting of Xenon/trimethylamine at various concentrations and pressures. The amplifying structure, made with photo-lithographic techniques similar to those followed in the fabrication of gas electron multipliers (GEMs), consisted of a 100 um-side equilateral-triangle pattern with 50 um-diameter holes placed at its vertexes. Once the primary electrons are guided into the holes by virtue of an optimized field configuration, avalanches develop along the 50 um-height channels etched out of the original doubly copper-clad polyimide foil. In order to properly account for the strong field gradients at the holes' entrance as well as for the fluctuations of the avalanche process (that ultimately determine the achievable energy resolution), we abandoned the hydrodynamic framework, resorting to a purely microscopic description of the electron trajectories as obtained from elementary cross-sections. We show that achieving a satisfactory description needs additional assumptions about atom-molecule (Penning) transfer reactions and charge recombination to be made.
△ Less
Submitted 16 June, 2015;
originally announced June 2015.
-
Accurate gamma and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atmospheres
Authors:
Diego Gonzalez-Diaz,
V. Alvarez,
F. I. G. Borges,
M. Camargo,
S. Carcel,
S. Cebrian,
A. Cervera,
C. A. N. Conde,
T. Dafni,
J. Diaz,
R. Esteve,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Goldschmidt,
J. J. Gomez-Cadenas,
R. M. Gutierrez,
J. Hauptman,
J. A. Hernando Morata,
D. C. Herrera,
I. G. Irastorza,
L. Labarga,
A. Laing
, et al. (58 additional authors not shown)
Abstract:
We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When operated at such a high pressure and in 1%-admixtures, trimethylamine (TMA) endows Xenon with an extremely low electron diffusion (1.3 +-0.13 mm-sigma (longitudinal)…
▽ More
We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When operated at such a high pressure and in 1%-admixtures, trimethylamine (TMA) endows Xenon with an extremely low electron diffusion (1.3 +-0.13 mm-sigma (longitudinal), 0.8 +-0.15 mm-sigma (transverse) along 1 m drift) besides forming a convenient Penning-Fluorescent mixture. The TPC, that houses 1.1 kg of gas in its active volume, operated continuously for 100 live-days in charge amplification mode. The readout was performed through the recently introduced microbulk Micromegas technology and the AFTER chip, providing a 3D voxelization of 8mm x 8mm x 1.2mm for approximately 10 cm/MeV-long electron tracks. This work was developed as part of the R&D program of the NEXT collaboration for future detector upgrades in the search of the 0bbnu decay in 136Xe, specifically those based on novel gas mixtures. Therefore we ultimately focus on the calorimetric and topological properties of the reconstructed MeV-electron tracks.
△ Less
Submitted 17 June, 2015; v1 submitted 14 April, 2015;
originally announced April 2015.
-
Charge Transfer Properties Through Graphene Layers in Gas Detectors
Authors:
P. Thuiner,
R. Hall-Wilton,
R. B. Jackman,
H. Müller,
T. T. Nguyen,
E. Oliveri,
D. Pfeiffer,
F. Resnati,
L. Ropelewski,
J. A. Smith,
M. van Stenis,
R. Veenhof
Abstract:
Graphene is a single layer of carbon atoms arranged in a honeycomb lattice with remarkable mechanical, electrical and optical properties. For the first time graphene layers suspended on copper meshes were installed into a gas detector equipped with a gaseous electron multiplier. Measurements of low energy electron and ion transfer through graphene were conducted. In this paper we describe the samp…
▽ More
Graphene is a single layer of carbon atoms arranged in a honeycomb lattice with remarkable mechanical, electrical and optical properties. For the first time graphene layers suspended on copper meshes were installed into a gas detector equipped with a gaseous electron multiplier. Measurements of low energy electron and ion transfer through graphene were conducted. In this paper we describe the sample preparation for suspended graphene layers, the testing procedures and we discuss the preliminary results followed by a prospect of further applications.
△ Less
Submitted 23 March, 2015;
originally announced March 2015.
-
A dynamic method for charging-up calculations: the case of GEM
Authors:
P. M. M. Correia,
C. A. B. Oliveira,
C. D. R. Azevedo,
A. L. M. Silva,
R. Veenhof,
Mythra Varun Nemallapudi,
J. F. C. A. Veloso
Abstract:
The simulation of Micro Pattern Gaseous Detectors (MPGDs) signal response is an important and powerful tool for the design and optimization of such detectors. However, several attempts to simulate exactly the effective charge gain have not been completely successful. Namely, the gain stability over time has not been fully understood. Charging-up of the insulator surfaces have been pointed as one o…
▽ More
The simulation of Micro Pattern Gaseous Detectors (MPGDs) signal response is an important and powerful tool for the design and optimization of such detectors. However, several attempts to simulate exactly the effective charge gain have not been completely successful. Namely, the gain stability over time has not been fully understood. Charging-up of the insulator surfaces have been pointed as one of the responsible for the difference between experimental and Monte Carlo results. This work describes two iterative methods to simulate the charging-up in one MPGD device, the Gas Electron Multiplier (GEM). The first method uses a constant step for avalanches time evolution, very detailed, but slower to compute. The second method uses a dynamic step that improves the computing time. Good agreement between both methods was reached. Despite of comparison with experimental results shows that charging-up plays an important role in detectors operation, should not be the only responsible for the difference between simulated and measured effective gain, but explains the time evolution in the effective gain.
△ Less
Submitted 22 January, 2014; v1 submitted 16 January, 2014;
originally announced January 2014.
-
Simulation of VUV electroluminescence in micropattern gaseous detectors: the case of GEM and MHSP
Authors:
C. A. B. Oliveira,
P. M. M. Correia,
H. Schindler,
A. L. Ferreira,
C. M. B. Monteiro,
J. M. F. dos Santos,
S. Biagi,
R. Veenhof,
J. F. C. A. Veloso
Abstract:
Electroluminescence produced during avalanche development in gaseous avalanche detectors is an useful information for triggering, calorimetry and tracking in gaseous detectors. Noble gases present high electroluminescence yields, emitting mainly in the VUV region. The photons can provide signal readout if appropriate photosensors are used. Micropattern gaseous detectors are good candidates for sig…
▽ More
Electroluminescence produced during avalanche development in gaseous avalanche detectors is an useful information for triggering, calorimetry and tracking in gaseous detectors. Noble gases present high electroluminescence yields, emitting mainly in the VUV region. The photons can provide signal readout if appropriate photosensors are used. Micropattern gaseous detectors are good candidates for signal amplification in high background and/or low rate experiments due to their high electroluminescence yields and radiopurity. In this work, the VUV light responses of the Gas Electron Multiplier and of the Micro-Hole Strip Plate, working with pure xenon, are simulated and studied in detail using a new and versatile C++ toolkit. It is shown that the solid angle subtended by a photosensor placed below the microstructures depends on the operating conditions. The obtained absolute EL yields, determined for different gas pressures and as functions of the applied voltage, are compared with those determined experimentally.
△ Less
Submitted 30 July, 2012; v1 submitted 7 June, 2012;
originally announced June 2012.
-
A comparative measurement of $φ\rightarrow K^+K^-$ and $φ\rightarrow μ^+μ^-$ in In-In collisions at the CERN SPS
Authors:
NA60 Collaboration,
R. Arnaldi,
K. Banicz,
J. Castor,
B. Chaurand,
W. Chen,
C. Cicalò,
A. Colla,
P. Cortese,
S. Damjanovic,
A. David,
A. de Falco,
A. Devaux,
L. Ducroux,
H. En'yo,
J. Fargeix,
A. Ferretti,
M. Floris,
A. Förster,
P. Force,
N. Guettet,
A. Guichard,
H. Gulkanian,
J. M. Heuser,
M. Keil
, et al. (27 additional authors not shown)
Abstract:
The NA60 experiment at the CERN SPS has studied $φ$ meson production in In-In collisions at 158A GeV via both the $K^+K^-$ and the $μ^+μ^-$ decay channels. The yields and inverse slope parameters of the $m_T$ spectra observed in the two channels are compatible within errors, different from the large discrepancies seen in Pb-Pb collisions between the hadronic (NA49) and dimuon (NA50) decay channels…
▽ More
The NA60 experiment at the CERN SPS has studied $φ$ meson production in In-In collisions at 158A GeV via both the $K^+K^-$ and the $μ^+μ^-$ decay channels. The yields and inverse slope parameters of the $m_T$ spectra observed in the two channels are compatible within errors, different from the large discrepancies seen in Pb-Pb collisions between the hadronic (NA49) and dimuon (NA50) decay channels. Possible physics implications are discussed.
△ Less
Submitted 20 April, 2011;
originally announced April 2011.
-
A simulation toolkit for electroluminescence assessment in rare event experiments
Authors:
C. A. B. Oliveira,
H. Schindler,
R. Veenhof,
S. Biagi,
C. M. B. Monteiro,
J. M. F. dos Santos,
A. L. Ferreira,
J. F. C. A. Veloso
Abstract:
A good understanding of electroluminescence is a prerequisite when optimising double-phase noble gas detectors for Dark Matter searches and high-pressure xenon TPCs for neutrinoless double beta decay detection.
A simulation toolkit for calculating the emission of light through electron impact on neon, argon, krypton and xenon has been developed using the Magboltz and Garfield programs. Calculate…
▽ More
A good understanding of electroluminescence is a prerequisite when optimising double-phase noble gas detectors for Dark Matter searches and high-pressure xenon TPCs for neutrinoless double beta decay detection.
A simulation toolkit for calculating the emission of light through electron impact on neon, argon, krypton and xenon has been developed using the Magboltz and Garfield programs. Calculated excitation and electroluminescence efficiencies, electroluminescence yield and associated statistical fluctuations are presented as a function of electric field. Good agreement with experiment and with Monte Carlo simulations has been obtained.
△ Less
Submitted 31 March, 2011;
originally announced March 2011.
-
J/psi production in proton-nucleus collisions at 158 and 400 GeV
Authors:
R. Arnaldi,
K. Banicz,
J. Castor,
B. Chaurand,
W. Chen,
C. Cicalo,
A. Colla,
P. Cortese,
S. Damjanovic,
A. David,
A. de Falco,
A. Devaux,
L. Ducroux,
H. En'yo,
J. Fargeix,
A. Ferretti,
M. Floris,
A. Foerster,
P. Force,
N. Guettet,
A. Guichard,
H. Gulkanian,
J. M. Heuser,
M. Keil,
Z. Li
, et al. (26 additional authors not shown)
Abstract:
The NA60 experiment has studied J/psi production in p-A collisions at 158 and 400 GeV, at the CERN SPS. Nuclear effects on the J/psi yield have been estimated from the A-dependence of the production cross section ratios sigma_{J/psi}^{A}/sigma_{J/psi}^{Be} (A=Al, Cu, In, W, Pb, U). We observe a significant nuclear suppression of the J/psi yield per nucleon-nucleon collision, with a larger effect a…
▽ More
The NA60 experiment has studied J/psi production in p-A collisions at 158 and 400 GeV, at the CERN SPS. Nuclear effects on the J/psi yield have been estimated from the A-dependence of the production cross section ratios sigma_{J/psi}^{A}/sigma_{J/psi}^{Be} (A=Al, Cu, In, W, Pb, U). We observe a significant nuclear suppression of the J/psi yield per nucleon-nucleon collision, with a larger effect at lower incident energy, and we compare this result with previous observations by other fixed-target experiments. An attempt to disentangle the different contributions to the observed suppression has been carried out by studying the dependence of nuclear effects on x_2, the fraction of nucleon momentum carried by the interacting parton in the target nucleus.
△ Less
Submitted 24 November, 2011; v1 submitted 30 April, 2010;
originally announced April 2010.
-
The ALICE TPC, a large 3-dimensional tracking device with fast readout for ultra-high multiplicity events
Authors:
J. Alme,
Y. Andres,
H. Appelshauser,
S. Bablok,
N. Bialas,
R. Bolgen,
U. Bonnes,
R. Bramm,
P. Braun-Munzinger,
R. Campagnolo,
P. Christiansen,
A. Dobrin,
C. Engster,
D. Fehlker,
P. Foka,
U. Frankenfeld,
J. J. Gaardhoje,
C. Garabatos,
P. Glassel,
C. Gonzalez Gutierrez,
P. Gros,
H. -A. Gustafsson,
H. Helstrup,
M. Hoch,
M. Ivanov
, et al. (51 additional authors not shown)
Abstract:
The design, construction, and commissioning of the ALICE Time-Projection Chamber (TPC) is described. It is the main device for pattern recognition, tracking, and identification of charged particles in the ALICE experiment at the CERN LHC. The TPC is cylindrical in shape with a volume close to 90 m^3 and is operated in a 0.5 T solenoidal magnetic field parallel to its axis.
In this paper we des…
▽ More
The design, construction, and commissioning of the ALICE Time-Projection Chamber (TPC) is described. It is the main device for pattern recognition, tracking, and identification of charged particles in the ALICE experiment at the CERN LHC. The TPC is cylindrical in shape with a volume close to 90 m^3 and is operated in a 0.5 T solenoidal magnetic field parallel to its axis.
In this paper we describe in detail the design considerations for this detector for operation in the extreme multiplicity environment of central Pb--Pb collisions at LHC energy. The implementation of the resulting requirements into hardware (field cage, read-out chambers, electronics), infrastructure (gas and cooling system, laser-calibration system), and software led to many technical innovations which are described along with a presentation of all the major components of the detector, as currently realized. We also report on the performance achieved after completion of the first round of stand-alone calibration runs and demonstrate results close to those specified in the TPC Technical Design Report.
△ Less
Submitted 12 January, 2010;
originally announced January 2010.
-
Highlights from NA60
Authors:
A. De Falco,
R. Arnaldi,
K. Banicz,
K. Borer,
J. Castor,
B. Chaurand,
W. Chen,
C. Cicalo,
A. Colla,
P. Cortese,
S. Damjanovic,
A. David,
A. Devaux,
L. Ducroux,
H. En'yo,
J. Fargeix,
A. Ferretti,
M. Floris,
P. Force,
A. Forster,
N. Guettet,
A. Guichard,
H. Gulkanian,
J. Heuser,
M. Keil
, et al. (28 additional authors not shown)
Abstract:
NA60 measured dimuon production in p-A and In-In collisions at the CERN SPS. This paper presents a high statistics measurement of $φ$ meson production in In-In collisions at 158 AGeV. Both the transverse momentum, rapidity, decay angular distributions and the absolute yield were measured as a function of centrality. The results are compared to previous measurements in order to shed light on the…
▽ More
NA60 measured dimuon production in p-A and In-In collisions at the CERN SPS. This paper presents a high statistics measurement of $φ$ meson production in In-In collisions at 158 AGeV. Both the transverse momentum, rapidity, decay angular distributions and the absolute yield were measured as a function of centrality. The results are compared to previous measurements in order to shed light on the long standing $φ$ puzzle. In addition, highlights on $η$ meson production and on the dimuon excess below the J/$ψ$ mass are presented.
△ Less
Submitted 21 April, 2009;
originally announced April 2009.
-
First results on angular distributions of thermal dileptons in nuclear collisions
Authors:
NA60 Collaboration,
R. Arnaldi,
K. Banicz,
K. Borer,
J. Castor,
B. Chaurand,
W. Chen,
C. Cicalo,
A. Colla,
P. Cortese,
S. Damjanovic,
A. David,
A. de Falco,
A. Devaux,
L. Ducroux,
H. En'yo,
J. Fargeix,
A. Ferretti,
M. Floris,
A. Foerster,
P. Force,
N. Guettet,
A. Guichard,
H. Gulkanian,
J. M. Heuser
, et al. (28 additional authors not shown)
Abstract:
The NA60 experiment at the CERN SPS has studied dimuon production in 158A GeV In-In collisions. The strong excess of pairs above the known sources found in the complete mass region 0.2<M<2.6 GeV has previously been interpreted as thermal radiation. We now present first results on the associated angular distributions. Using the Collins-Soper reference frame, the structure function parameters λ, μ…
▽ More
The NA60 experiment at the CERN SPS has studied dimuon production in 158A GeV In-In collisions. The strong excess of pairs above the known sources found in the complete mass region 0.2<M<2.6 GeV has previously been interpreted as thermal radiation. We now present first results on the associated angular distributions. Using the Collins-Soper reference frame, the structure function parameters λ, μand νare measured to be zero, and the projected distributions in polar and azimuth angles are found to be uniform. The absence of any polarization is consistent with the interpretation of the excess dimuons as thermal radiation from a randomized system.
△ Less
Submitted 16 December, 2008;
originally announced December 2008.
-
NA60 results on thermal dimuons
Authors:
NA60 Collaboration,
R. Arnaldi,
K. Banicz,
K. Borer,
J. Castor,
B. Chaurand,
W. Chen,
C. Cicalo,
A. Colla,
P. Cortese,
S. Damjanovic,
A. David,
A. de Falco,
A. Devaux,
L. Ducroux,
H. En'yo,
J. Fargeix,
A. Ferretti,
M. Floris,
A. Foerster,
P. Force,
N. Guettet,
A. Guichard,
H. Gulkanian,
J. M. Heuser
, et al. (28 additional authors not shown)
Abstract:
The NA60 experiment at the CERN SPS has measured muon pairs with unprecedented precision in 158A GeV In-In collisions. A strong excess of pairs above the known sources is observed in the whole mass region 0.2<M<2.6 GeV. The mass spectrum for M<1 GeV is consistent with a dominant contribution from pi+pi- -> rho -> mu+mu- annihilation. The associated rho spectral function shows a strong broadening…
▽ More
The NA60 experiment at the CERN SPS has measured muon pairs with unprecedented precision in 158A GeV In-In collisions. A strong excess of pairs above the known sources is observed in the whole mass region 0.2<M<2.6 GeV. The mass spectrum for M<1 GeV is consistent with a dominant contribution from pi+pi- -> rho -> mu+mu- annihilation. The associated rho spectral function shows a strong broadening, but essentially no shift in mass. For M>1 GeV, the excess is found to be prompt, not due to enhanced charm production, with pronounced differences to Drell-Yan pairs. The slope parameter Teff associated with the transverse momentum spectra rises with mass up to the rho, followed by a sudden decline above. The rise for M<1 GeV is consistent with radial flow of a hadronic emission source. The seeming absence of significant flow for M>1 GeV and its relation to parton-hadron duality is discussed in detail, suggesting a dominantly partonic emission source in this region. A comparison of the data to the present status of theoretical modeling is also contained. The accumulated empirical evidence, including also a Planck-like shape of the mass spectra at low pT and the lack of polarization, is consistent with a global interpretation of the excess dimuons as thermal radiation. We conclude with first results on omega in-medium effects.
△ Less
Submitted 16 December, 2008;
originally announced December 2008.
-
Evidence for the production of thermal muon pairs with masses above 1 GeV/c^2 in 158A GeV Indium-Indium Collisions
Authors:
NA60 Collaboration,
R. Arnaldi,
K. Banicz,
K. Borer,
J. Castor,
B. Chaurand,
W. Chen,
C. Cicalo,
A. Colla,
P. Cortese,
S. Damjanovic,
A. David,
A. de Falco,
A. Devaux,
L. Ducroux,
H. Enyo,
J. Fargeix,
A. Ferretti,
M. Floris,
A. Forster,
P. Force,
N. Guettet,
A. Guichard,
H. Gulkanian,
J. M. Heuser
, et al. (28 additional authors not shown)
Abstract:
The yield of muon pairs in the invariant mass region 1<M<2.5 GeV/c^2 produced in heavy-ion collisions significantly exceeds the sum of the two expected contributions, Drell-Yan dimuons and muon pairs from the decays of D meson pairs. These sources properly account for the dimuons produced in proton-nucleus collisions. In this paper, we show that dimuons are also produced in excess in 158 A GeV I…
▽ More
The yield of muon pairs in the invariant mass region 1<M<2.5 GeV/c^2 produced in heavy-ion collisions significantly exceeds the sum of the two expected contributions, Drell-Yan dimuons and muon pairs from the decays of D meson pairs. These sources properly account for the dimuons produced in proton-nucleus collisions. In this paper, we show that dimuons are also produced in excess in 158 A GeV In-In collisions. We furthermore observe, by tagging the dimuon vertices, that this excess is not due to enhanced D meson production, but made of prompt muon pairs, as expected from a source of thermal dimuons specific to high-energy nucleus-nucleus collisions. The yield of this excess increases significantly from peripheral to central collisions, both with respect to the Drell-Yan yield and to the number of nucleons participating in the collisions. Furthermore, the transverse mass distributions of the excess dimuons are well described by an exponential function, with inverse slope values around 190 MeV. The values are independent of mass and significantly lower than those found at masses below 1 GeV/c^2, rising there up to 250 MeV due to radial flow. This suggests the emission source of thermal dimuons above 1 GeV/c^2 to be of largely partonic origin, when radial flow has not yet built up.
△ Less
Submitted 16 December, 2008; v1 submitted 17 October, 2008;
originally announced October 2008.
-
Highlights from the NA60 experiment
Authors:
A. Ferretti,
R. Arnaldi,
R. Averbeck,
K. Banicz,
J. Castor,
B. Chaurand,
C. Cicalò,
A. Colla,
P. Cortese,
S. Damjanovic,
A. David,
A. De Falco,
A. Devaux,
A. Drees,
L. Ducroux,
H. En'yo,
M. Floris,
A. Förster,
P. Force,
N. Guettet,
A. Guichard,
H. Gulkanyan,
J. M. Heuser,
M. Keil,
L. Kluberg
, et al. (24 additional authors not shown)
Abstract:
The NA60 experiment is a fixed-target experiment at the CERN SPS. It has measured the dimuon yield in Indium--Indium collisions with an In beam of 158 AGeV/c and in p-A collisions with a proton beam of 400 and 158 AGeV/c. The results allow to address three important physics topics, namely the study of the rho spectral function in nuclear collisions, the clarification of the origin of the dimuon…
▽ More
The NA60 experiment is a fixed-target experiment at the CERN SPS. It has measured the dimuon yield in Indium--Indium collisions with an In beam of 158 AGeV/c and in p-A collisions with a proton beam of 400 and 158 AGeV/c. The results allow to address three important physics topics, namely the study of the rho spectral function in nuclear collisions, the clarification of the origin of the dimuon excess measured by NA50 in the intermediate mass range, and the J/psi suppression pattern in a collision system different from Pb-Pb. An overview of these results will be given in this paper.
△ Less
Submitted 23 May, 2007;
originally announced May 2007.
-
Estimation of Weighting Potential for a TPC
Authors:
S. Mukhopadhyay,
N. Majumdar,
R. Veenhof
Abstract:
In this work, we have computed the three dimensional weighting potential, field and pad response function (PRF) of typical time projection chambers (TPC) using a recently formulated and developed boundary element method solver, namely, the nearly exact BEM solver. A realistic geometry of the device is found to have significant influence on the estimation of signal generation.
In this work, we have computed the three dimensional weighting potential, field and pad response function (PRF) of typical time projection chambers (TPC) using a recently formulated and developed boundary element method solver, namely, the nearly exact BEM solver. A realistic geometry of the device is found to have significant influence on the estimation of signal generation.
△ Less
Submitted 1 March, 2007;
originally announced March 2007.
-
J/$ψ$ suppression in In-In collisions at 158 GeV/nucleon
Authors:
R. Arnaldi,
NA60 Collaboration R. Arnaldi,
R. Averbeck,
K. Banicz,
J. Castor,
B. Chaurand,
C. Cicalo',
A. Colla,
P. Cortese,
S. Damjanovic,
A. David,
A. DeFalco,
A. Devaux,
A. Drees,
L. Ducroux,
H. En'yo,
A. Ferretti,
M. Floris,
A. Forster,
P. Force,
N. Guettet,
A. Guichard,
H. Gulkanian,
J. Heuser,
M. Keil
, et al. (25 additional authors not shown)
Abstract:
The NA60 experiment has studied J/$ψ$ production in Indium-Indium collisions at 158 A$\cdot$GeV. In this paper we present an updated set of results obtained with the complete set of available statistics and an improved alignment of the vertex tracker. The centrality dependence of the J/$ψ$ production, obtained with an analysis technique based only on the J/$ψ$ sample, indicates that a suppressio…
▽ More
The NA60 experiment has studied J/$ψ$ production in Indium-Indium collisions at 158 A$\cdot$GeV. In this paper we present an updated set of results obtained with the complete set of available statistics and an improved alignment of the vertex tracker. The centrality dependence of the J/$ψ$ production, obtained with an analysis technique based only on the J/$ψ$ sample, indicates that a suppression beyond that induced by nuclear absorption is present in In-In collisions, setting in at $\sim$80 participant nucleons. A first study of the systematic errors related with this measurement is discussed. We also present preliminary results on the J/$ψ$ azimuthal distributions.
△ Less
Submitted 22 January, 2007;
originally announced January 2007.
-
Low Mass Dimuon Production in Indium-Indium Collisions at the CERN SPS
Authors:
NA60 Collaboration,
M. Floris,
R. Arnaldi,
R. Averbeck,
K. Banicz,
J. Castor,
B. Chaurand,
C. Cicalo,
A. Colla,
P. Cortese,
S. Damjanovic,
A. David,
A. de Falco,
A. Devaux,
A. Dress,
L. Ducroux,
J. Farjeix,
H. En'yo,
A. Ferretti,
A. Förster,
P. Force,
N. Guettet,
A. Guichard,
H. Gulkanian,
J. Heuser
, et al. (26 additional authors not shown)
Abstract:
NA60 is a fixed-target experiment at the CERN SPS which measured dimuon production in nucleus-nucleus and proton-nucleus collisions. In this paper we report on a precision measurement of low-mass muon pairs in 158 AGeV indium-indium collisions. A significant excess of pairs is observed above the yield expected from neutral meson decays. The excess can be isolated by subtraction of expected sourc…
▽ More
NA60 is a fixed-target experiment at the CERN SPS which measured dimuon production in nucleus-nucleus and proton-nucleus collisions. In this paper we report on a precision measurement of low-mass muon pairs in 158 AGeV indium-indium collisions. A significant excess of pairs is observed above the yield expected from neutral meson decays. The excess can be isolated by subtraction of expected sources, thanks to the excellent mass resolution and large sample size.
△ Less
Submitted 19 June, 2006;
originally announced June 2006.
-
Study of dimuon production in Indium-Indium collisions with the NA60 experiment
Authors:
R. Shahoyan,
R. Arnaldi,
K. Banicz,
J. Castor,
B. Chaurand,
C. Cicalo,
A. Colla,
P. Cortese,
S. Damjanovic,
A. David,
A. de Falco,
A. Devaux,
L. Ducroux,
H. En'yo,
A. Ferretti,
M. Floris,
P. Force,
N. Guettet,
A. Guichard,
H. Gulkanian,
J. Heuser,
M. Keil,
L. Kluberg,
J. Lozano,
C. Lourenco
, et al. (21 additional authors not shown)
Abstract:
The NA60 experiment at the CERN-SPS is devoted to the study of dimuon production in heavy-ion and proton-nucleus collisions. We present preliminary results from the analysis of Indium-Indium collisions at 158 GeV per nucleon. The topics covered are low mass vector meson production, J/psi production and suppression, and the feasibility of the open charm measurement from the dimuon continuum in th…
▽ More
The NA60 experiment at the CERN-SPS is devoted to the study of dimuon production in heavy-ion and proton-nucleus collisions. We present preliminary results from the analysis of Indium-Indium collisions at 158 GeV per nucleon. The topics covered are low mass vector meson production, J/psi production and suppression, and the feasibility of the open charm measurement from the dimuon continuum in the mass range below the J/psi peak.
△ Less
Submitted 17 May, 2005; v1 submitted 16 May, 2005;
originally announced May 2005.