-
Scaling quantum computing with dynamic circuits
Authors:
Almudena Carrera Vazquez,
Caroline Tornow,
Diego Riste,
Stefan Woerner,
Maika Takita,
Daniel J. Egger
Abstract:
Quantum computers process information with the laws of quantum mechanics. Current quantum hardware is noisy, can only store information for a short time, and is limited to a few quantum bits, i.e., qubits, typically arranged in a planar connectivity. However, many applications of quantum computing require more connectivity than the planar lattice offered by the hardware on more qubits than is avai…
▽ More
Quantum computers process information with the laws of quantum mechanics. Current quantum hardware is noisy, can only store information for a short time, and is limited to a few quantum bits, i.e., qubits, typically arranged in a planar connectivity. However, many applications of quantum computing require more connectivity than the planar lattice offered by the hardware on more qubits than is available on a single quantum processing unit (QPU). Here we overcome these limitations with error mitigated dynamic circuits and circuit-cutting to create quantum states requiring a periodic connectivity employing up to 142 qubits spanning multiple QPUs connected in real-time with a classical link. In a dynamic circuit, quantum gates can be classically controlled by the outcomes of mid-circuit measurements within run-time, i.e., within a fraction of the coherence time of the qubits. Our real-time classical link allows us to apply a quantum gate on one QPU conditioned on the outcome of a measurement on another QPU which enables a modular scaling of quantum hardware. Furthermore, the error mitigated control-flow enhances qubit connectivity and the instruction set of the hardware thus increasing the versatility of our quantum computers. Dynamic circuits and quantum modularity are thus key to scale quantum computers and make them useful.
△ Less
Submitted 27 February, 2024;
originally announced February 2024.
-
Well-conditioned multi-product formulas for hardware-friendly Hamiltonian simulation
Authors:
Almudena Carrera Vazquez,
Daniel J. Egger,
David Ochsner,
Stefan Woerner
Abstract:
Simulating the time-evolution of a Hamiltonian is one of the most promising applications of quantum computers. Multi-Product Formulas (MPFs) are well suited to replace standard product formulas since they scale better with respect to time and approximation errors. Hamiltonian simulation with MPFs was first proposed in a fully quantum setting using a linear combination of unitaries. Here, we analyz…
▽ More
Simulating the time-evolution of a Hamiltonian is one of the most promising applications of quantum computers. Multi-Product Formulas (MPFs) are well suited to replace standard product formulas since they scale better with respect to time and approximation errors. Hamiltonian simulation with MPFs was first proposed in a fully quantum setting using a linear combination of unitaries. Here, we analyze and demonstrate a hybrid quantum-classical approach to MPFs that classically combines expectation values evaluated with a quantum computer. This has the same approximation bounds as the fully quantum MPFs, but, in contrast, requires no additional qubits, no controlled operations, and is not probabilistic. We show how to design MPFs that do not amplify the hardware and sampling errors, and demonstrate their performance. In particular, we illustrate the potential of our work by theoretically analyzing the benefits when applied to a classically intractable spin-boson model, and by computing the dynamics of the transverse field Ising model using a classical simulator as well as quantum hardware. We observe an error reduction of up to an order of magnitude when compared to a product formula approach by suppressing hardware noise with Pauli Twirling, pulse efficient transpilation, and a novel zero-noise extrapolation based on scaled cross-resonance pulses. The MPF methodology reduces the circuit depth and may therefore represent an important step towards quantum advantage for Hamiltonian simulation on noisy hardware.
△ Less
Submitted 24 July, 2023; v1 submitted 22 July, 2022;
originally announced July 2022.
-
Teaching quantum computing with an interactive textbook
Authors:
James R. Wootton,
Francis Harkins,
Nicholas T. Bronn,
Almudena Carrera Vazquez,
Anna Phan,
Abraham T. Asfaw
Abstract:
Quantum computing is a technology that promises to offer significant advantages during the coming decades. Though the technology is still in a prototype stage, the last few years have seen many of these prototype devices become accessible to the public. This has been accompanied by the open-source development of the software required to use and test quantum hardware in increasingly sophisticated w…
▽ More
Quantum computing is a technology that promises to offer significant advantages during the coming decades. Though the technology is still in a prototype stage, the last few years have seen many of these prototype devices become accessible to the public. This has been accompanied by the open-source development of the software required to use and test quantum hardware in increasingly sophisticated ways. Such tools provide new education opportunities, not just for quantum computing specifically, but also more broadly for quantum information science and even quantum physics as a whole. In this paper we present a case study of one education resource which aims to take advantage of the opportunities: the open-source online textbook `Learn Quantum Computation using Qiskit'. An overview of the topics covered is given, as well as an explanation of the approach taken for each.
△ Less
Submitted 16 December, 2020;
originally announced December 2020.
-
Enhancing the Quantum Linear Systems Algorithm using Richardson Extrapolation
Authors:
Almudena Carrera Vazquez,
Ralf Hiptmair,
Stefan Woerner
Abstract:
We present a quantum algorithm to solve systems of linear equations of the form $A\mathbf{x}=\mathbf{b}$, where $A$ is a tridiagonal Toeplitz matrix and $\mathbf{b}$ results from discretizing an analytic function, with a circuit complexity of $poly(\log(κ), 1/\sqrtε, \log(N))$, where $N$ denotes the number of equations, $ε$ is the accuracy, and $κ$ the condition number. The \emph{repeat-until-succ…
▽ More
We present a quantum algorithm to solve systems of linear equations of the form $A\mathbf{x}=\mathbf{b}$, where $A$ is a tridiagonal Toeplitz matrix and $\mathbf{b}$ results from discretizing an analytic function, with a circuit complexity of $poly(\log(κ), 1/\sqrtε, \log(N))$, where $N$ denotes the number of equations, $ε$ is the accuracy, and $κ$ the condition number. The \emph{repeat-until-success} algorithm has to be run $\mathcal{O}\left(κ/(1-ε)\right)$ times to succeed, leveraging amplitude amplification, and sampled $\mathcal{O}(1/ε^2)$ times. Thus, the algorithm achieves an exponential improvement with respect to $N$ over classical methods. In particular, we present efficient oracles for state preparation, Hamiltonian simulation and a set of observables together with the corresponding error and complexity analyses. As the main result of this work, we show how to use Richardson extrapolation to enhance Hamiltonian simulation, resulting in an implementation of Quantum Phase Estimation (QPE) within the algorithm with $1/\sqrtε$ circuit complexity instead of $1/ε$ and which can be parallelized. Furthermore, we analyze necessary conditions for the overall algorithm to achieve an exponential speedup compared to classical methods. Our approach is not limited to the considered setting and can be applied to more general problems where Hamiltonian simulation is approximated via product formulae, although, our theoretical results would need to be extended accordingly. All the procedures presented are implemented with Qiskit and tested for small systems using classical simulation as well as using real quantum devices available through the IBM Quantum Experience.
△ Less
Submitted 5 July, 2021; v1 submitted 9 September, 2020;
originally announced September 2020.
-
Herramientas tecnológicas en Android para la formación de mapeadores y promotores de Mapa Verde
Authors:
Yosvany Medina Carbó,
C. Álvaro Celestino Alonso Vázquez,
Reina María Rodríguez García
Abstract:
When you talk about technologies and the environment, you usually imagine a lot of equipment, techniques, technologies and tools polluting the natural environment. The good and bad consequences of our development have been projected on the planet for years, and part of that development is reflected in the new technologies, among which is the mobile phone. In the municipality of Consolación del Sur…
▽ More
When you talk about technologies and the environment, you usually imagine a lot of equipment, techniques, technologies and tools polluting the natural environment. The good and bad consequences of our development have been projected on the planet for years, and part of that development is reflected in the new technologies, among which is the mobile phone. In the municipality of Consolación del Sur and from the Municipal University Center, the project Implementation of the Green Map Methodology in the management of environmental education in console communities for the formation of an environmental culture for sustainable development is created, creating awareness of care and protection of the environment. The present work is given to solve the following problem: how to contribute in the construction of a package of computer tools for the implementation of the Green Map methodology in environmental management in console communities and the training of mappers and promoters of Green Map for the development of green maps of the communities of the municipality Consolación del Sur? For this purpose, two Android applications for mobile devices based on the Green Map methodology were developed, thus responding to the following objective: Develop a package of computer applications for the implementation of the Green Map methodology in the management of environmental education in console communities and the formation of mappers and promoters of the Green Map that allows the development of the green maps of the communities of the Consolación del Sur municipality.
△ Less
Submitted 21 July, 2020;
originally announced August 2020.
-
Efficient State Preparation for Quantum Amplitude Estimation
Authors:
Almudena Carrera Vazquez,
Stefan Woerner
Abstract:
Quantum Amplitude Estimation (QAE) can achieve a quadratic speed-up for applications classically solved by Monte Carlo simulation. A key requirement to realize this advantage is efficient state preparation. If state preparation is too expensive, it can diminish the quantum advantage. Preparing arbitrary quantum states has exponential complexity with respect to the number of qubits, thus, is not ap…
▽ More
Quantum Amplitude Estimation (QAE) can achieve a quadratic speed-up for applications classically solved by Monte Carlo simulation. A key requirement to realize this advantage is efficient state preparation. If state preparation is too expensive, it can diminish the quantum advantage. Preparing arbitrary quantum states has exponential complexity with respect to the number of qubits, thus, is not applicable. Currently known efficient techniques require problems based on log-concave probability distributions, involve learning an unknown distribution from empirical data, or fully rely on quantum arithmetic. In this paper, we introduce an approach to simplify state preparation, together with a circuit optimization technique, both of which can help reduce the circuit complexity for QAE state preparation significantly. We demonstrate the introduced techniques for a numerical integration example on real quantum hardware, as well as for option pricing under the Heston model, i.e., based on a stochastic volatility process, using simulation.
△ Less
Submitted 15 May, 2020;
originally announced May 2020.
-
First Direct-Detection Constraints on eV-Scale Hidden-Photon Dark Matter with DAMIC at SNOLAB
Authors:
A. Aguilar-Arevalo,
D. Amidei,
X. Bertou,
M. Butner,
G. Cancelo,
A. Castañeda Vázquez,
B. A. Cervantes Vergara,
A. E. Chavarria,
C. R. Chavez,
J. R. T. de Mello Neto,
J. C. D'Olivo,
J. Estrada,
G. Fernandez Moroni,
R. Gaïor,
Y. Guardincerri,
K. P. Hernández Torres,
F. Izraelevitch,
A. Kavner,
B. Kilminster,
I. Lawson,
A. Letessier-Selvon,
J. Liao,
A. Matalon,
V. B. B. Mello,
J. Molina
, et al. (13 additional authors not shown)
Abstract:
We present direct detection constraints on the absorption of hidden-photon dark matter with particle masses in the range 1.2-30 eV$c^{-2}$ with the DAMIC experiment at SNOLAB. Under the assumption that the local dark matter is entirely constituted of hidden photons, the sensitivity to the kinetic mixing parameter $κ$ is competitive with constraints from solar emission, reaching a minimum value of…
▽ More
We present direct detection constraints on the absorption of hidden-photon dark matter with particle masses in the range 1.2-30 eV$c^{-2}$ with the DAMIC experiment at SNOLAB. Under the assumption that the local dark matter is entirely constituted of hidden photons, the sensitivity to the kinetic mixing parameter $κ$ is competitive with constraints from solar emission, reaching a minimum value of 2.2$\times$$10^{-14}$ at 17 eV$c^{-2}$. These results are the most stringent direct detection constraints on hidden-photon dark matter in the galactic halo with masses 3-12 eV$c^{-2}$ and the first demonstration of direct experimental sensitivity to ionization signals $<$12 eV from dark matter interactions.
△ Less
Submitted 11 April, 2017; v1 submitted 9 November, 2016;
originally announced November 2016.
-
The CONNIE experiment
Authors:
CONNIE Collaboration,
A. Aguilar-Arevalo,
X. Bertou,
C. Bonifazi,
M. Butner,
G. Cancelo,
A. Castaneda Vazquez,
B. Cervantes Vergara,
C. R. Chavez,
H. Da Motta,
J. C. D'Olivo,
J. Dos Anjos,
J. Estrada,
G. Fernandez Moroni,
R. Ford,
A. Foguel,
K. P. Hernandez Torres,
F. Izraelevitch,
A. Kavner,
B. Kilminster,
K. Kuk,
H. P. Lima Jr.,
M. Makler,
J. Molina,
G. Moreno-Granados
, et al. (6 additional authors not shown)
Abstract:
The CONNIE experiment uses fully depleted, high resistivity CCDs as particle detectors in an attempt to measure for the first time the Coherent Neutrino-Nucleus Elastic Scattering of antineutrinos from a nuclear reactor with silicon nuclei.This talk, given at the XV Mexican Workshop on Particles and Fields (MWPF), discussed the potential of CONNIE to perform this measurement, the installation prog…
▽ More
The CONNIE experiment uses fully depleted, high resistivity CCDs as particle detectors in an attempt to measure for the first time the Coherent Neutrino-Nucleus Elastic Scattering of antineutrinos from a nuclear reactor with silicon nuclei.This talk, given at the XV Mexican Workshop on Particles and Fields (MWPF), discussed the potential of CONNIE to perform this measurement, the installation progress at the Angra dos Reis nuclear power plant, as well as the plans for future upgrades.
△ Less
Submitted 10 October, 2016; v1 submitted 4 August, 2016;
originally announced August 2016.
-
Search for low-mass WIMPs in a 0.6 kg day exposure of the DAMIC experiment at SNOLAB
Authors:
A. Aguilar-Arevalo,
D. Amidei,
X. Bertou,
M. Butner,
G. Cancelo,
A. Castañeda Vázquez,
B. A. Cervantes Vergara,
A. E. Chavarria,
C. R. Chavez,
J. R. T. de Mello Neto,
J. C. D'Olivo,
J. Estrada,
G. Fernandez Moroni,
R. Gaïor,
Y. Guandincerri,
K. P. Hernández Torres,
F. Izraelevitch,
A. Kavner,
B. Kilminster,
I. Lawson,
A. Letessier-Selvon,
J. Liao,
J. Molina,
J. R. Peña,
P. Privitera
, et al. (13 additional authors not shown)
Abstract:
We present results of a dark matter search performed with a 0.6 kg day exposure of the DAMIC experiment at the SNOLAB underground laboratory. We measure the energy spectrum of ionization events in the bulk silicon of charge-coupled devices down to a signal of 60 eV electron equivalent. The data are consistent with radiogenic backgrounds, and constraints on the spin-independent WIMP-nucleon elastic…
▽ More
We present results of a dark matter search performed with a 0.6 kg day exposure of the DAMIC experiment at the SNOLAB underground laboratory. We measure the energy spectrum of ionization events in the bulk silicon of charge-coupled devices down to a signal of 60 eV electron equivalent. The data are consistent with radiogenic backgrounds, and constraints on the spin-independent WIMP-nucleon elastic-scattering cross section are accordingly placed. A region of parameter space relevant to the potential signal from the CDMS-II Si experiment is excluded using the same target for the first time. This result obtained with a limited exposure demonstrates the potential to explore the low-mass WIMP region (<10 GeV/$c^{2}$) of the upcoming DAMIC100, a 100 g detector currently being installed in SNOLAB.
△ Less
Submitted 9 November, 2016; v1 submitted 25 July, 2016;
originally announced July 2016.
-
Results of the engineering run of the Coherent Neutrino Nucleus Interaction Experiment (CONNIE)
Authors:
A. Aguilar-Arevalo,
X. Bertou,
C. Bonifazi,
M. Butner,
G. Cancelo,
A. Castaneda Vazquez,
C. R. Chavez,
H. Da Motta,
J. C. DOlivo,
J. Dos Anjos,
J. Estrada,
G. Fernandez Moroni,
R. Ford,
A. Foguel,
K. P. Hernandez Torres,
F. Izraelevitch,
H. P. Lima Jr.,
B. Kilminster,
K. Kuk,
M. Makler,
J. Molina,
G. Moreno-Granados,
J. M. Moro,
E. E. Paolini,
M. Sofo Haro
, et al. (3 additional authors not shown)
Abstract:
The CONNIE detector prototype is operating at a distance of 30 m from the core of a 3.8 GW$_{\rm th}$ nuclear reactor with the goal of establishing Charge-Coupled Devices (CCD) as a new technology for the detection of coherent elastic neutrino-nucleus scattering. We report on the results of the engineering run with an active mass of 4 g of silicon. The CCD array is described, and the performance o…
▽ More
The CONNIE detector prototype is operating at a distance of 30 m from the core of a 3.8 GW$_{\rm th}$ nuclear reactor with the goal of establishing Charge-Coupled Devices (CCD) as a new technology for the detection of coherent elastic neutrino-nucleus scattering. We report on the results of the engineering run with an active mass of 4 g of silicon. The CCD array is described, and the performance observed during the first year is discussed. A compact passive shield was deployed for the detector, producing an order of magnitude reduction in the background rate. The remaining background observed during the run was stable, and dominated by internal contamination in the detector packaging materials. The {\it in-situ} calibration of the detector using X-ray lines from fluorescence demonstrates good stability of the readout system. The event rates with the reactor on and off are compared, and no excess is observed coming from nuclear fission at the power plant. The upper limit for the neutrino event rate is set two orders of magnitude above the expectations for the standard model. The results demonstrate the cryogenic CCD-based detector can be remotely operated at the reactor site with stable noise below 2 e$^-$ RMS and stable background rates. The success of the engineering test provides a clear path for the upgraded 100 g detector to be deployed during 2016.
△ Less
Submitted 5 April, 2016;
originally announced April 2016.
-
The DAMIC dark matter experiment
Authors:
A. Aguilar-Arevalo,
D. Amidei,
X. Bertou,
D. Bole,
M. Butner,
G. Cancelo,
A. Castañeda Vázquez,
A. E. Chavarria,
J. R. T. de Mello Neto,
S. Dixon,
J. C. D'Olivo,
J. Estrada,
G. Fernandez Moroni,
K. P. Hernández Torres,
F. Izraelevitch,
A. Kavner,
B. Kilminster,
I. Lawson,
J. Liao,
M. López,
J. Molina,
G. Moreno-Granados,
J. Pena,
P. Privitera,
Y. Sarkis
, et al. (8 additional authors not shown)
Abstract:
The DAMIC (Dark Matter in CCDs) experiment uses high resistivity, scientific grade CCDs to search for dark matter. The CCD's low electronic noise allows an unprecedently low energy threshold of a few tens of eV that make it possible to detect silicon recoils resulting from interactions of low mass WIMPs. In addition the CCD's high spatial resolution and the excellent energy response results in ver…
▽ More
The DAMIC (Dark Matter in CCDs) experiment uses high resistivity, scientific grade CCDs to search for dark matter. The CCD's low electronic noise allows an unprecedently low energy threshold of a few tens of eV that make it possible to detect silicon recoils resulting from interactions of low mass WIMPs. In addition the CCD's high spatial resolution and the excellent energy response results in very effective background identification techniques. The experiment has a unique sensitivity to dark matter particles with masses below 10 GeV/c$^2$. Previous results have demonstrated the potential of this technology, motivating the construction of DAMIC100, a 100 grams silicon target detector currently being installed at SNOLAB. In this contribution, the mode of operation and unique imaging capabilities of the CCDs, and how they may be exploited to characterize and suppress backgrounds will be discussed, as well as physics results after one year of data taking.
△ Less
Submitted 7 October, 2015;
originally announced October 2015.
-
Status of the DAMIC direct dark matter search experiment
Authors:
DAMIC Collaboration,
A. Aguilar-Arevalo,
D. Amidei,
X. Bertou,
D. Boule,
M. Butner,
G. Cancelo,
A. Castañeda Vázquez,
A. E. Chavarría,
J. R. T. de Melo Neto,
S. Dixon,
J. C. D'Olivo,
J. Estrada,
G. Fernandez Moroni,
K. P. Hernández Torres,
F. Izraelevitch,
A. Kavner,
B. Kilminster,
I. Lawson,
J. Liao,
M. López,
J. Molina,
G. Moreno-Granados,
J. Pena,
P. Privitera
, et al. (9 additional authors not shown)
Abstract:
The DAMIC experiment uses fully depleted, high resistivity CCDs to search for dark matter particles. With an energy threshold $\sim$50 eV$_{ee}$, and excellent energy and spatial resolutions, the DAMIC CCDs are well-suited to identify and suppress radioactive backgrounds, having an unrivaled sensitivity to WIMPs with masses $<$6 GeV/$c^2$. Early results motivated the construction of a 100 g detect…
▽ More
The DAMIC experiment uses fully depleted, high resistivity CCDs to search for dark matter particles. With an energy threshold $\sim$50 eV$_{ee}$, and excellent energy and spatial resolutions, the DAMIC CCDs are well-suited to identify and suppress radioactive backgrounds, having an unrivaled sensitivity to WIMPs with masses $<$6 GeV/$c^2$. Early results motivated the construction of a 100 g detector, DAMIC100, currently being installed at SNOLAB. This contribution discusses the installation progress, new calibration efforts near the threshold, a preliminary result with 2014 data, and the prospects for physics results after one year of data taking.
△ Less
Submitted 8 December, 2015; v1 submitted 30 September, 2015;
originally announced October 2015.
-
Measurement of radioactive contamination in the high-resistivity silicon CCDs of the DAMIC experiment
Authors:
A. Aguilar-Arevalo,
D. Amidei,
X. Bertou,
D. Bole,
M. Butner,
G. Cancelo,
A. Castañeda Vázquez,
A. E. Chavarria,
J. R. T. de Mello Neto,
S. Dixon,
J. C. D'Olivo,
J. Estrada,
G. Fernandez Moroni,
K. P. Hernández Torres,
F. Izraelevitch,
A. Kavner,
B. Kilminster,
I. Lawson,
J. Liao,
M. López,
J. Molina,
G. Moreno-Granados,
J. Pena,
P. Privitera,
Y. Sarkis
, et al. (8 additional authors not shown)
Abstract:
We present measurements of radioactive contamination in the high-resistivity silicon charge-coupled devices (CCDs) used by the DAMIC experiment to search for dark matter particles. Novel analysis methods, which exploit the unique spatial resolution of CCDs, were developed to identify $α$ and $β$ particles. Uranium and thorium contamination in the CCD bulk was measured through $α$ spectroscopy, wit…
▽ More
We present measurements of radioactive contamination in the high-resistivity silicon charge-coupled devices (CCDs) used by the DAMIC experiment to search for dark matter particles. Novel analysis methods, which exploit the unique spatial resolution of CCDs, were developed to identify $α$ and $β$ particles. Uranium and thorium contamination in the CCD bulk was measured through $α$ spectroscopy, with an upper limit on the $^{238}$U ($^{232}$Th) decay rate of 5 (15) kg$^{-1}$ d$^{-1}$ at 95% CL. We also searched for pairs of spatially correlated electron tracks separated in time by up to tens of days, as expected from $^{32}$Si-$^{32}$P or $^{210}$Pb-$^{210}$Bi sequences of $β$ decays. The decay rate of $^{32}$Si was found to be $80^{+110}_{-65}$ kg$^{-1}$ d$^{-1}$ (95% CI). An upper limit of $\sim$35 kg$^{-1}$ d$^{-1}$ (95% CL) on the $^{210}$Pb decay rate was obtained independently by $α$ spectroscopy and the $β$ decay sequence search. These levels of radioactive contamination are sufficiently low for the successful operation of CCDs in the forthcoming 100 g DAMIC detector.
△ Less
Submitted 9 July, 2015; v1 submitted 8 June, 2015;
originally announced June 2015.