-
MBD: Multi b-value Denoising of Diffusion Magnetic Resonance Images
Authors:
Jakub Jurek,
Andrzej Materka,
Kamil Ludwisiak,
Agata Majos,
Filip Szczepankiewicz
Abstract:
We propose a novel approach to denoising diffusion magnetic resonance images (dMRI) using convolutional neural networks, that exploits the benefits of data acquired at multiple b-values to offset the need for many redundant observations. Denoising is especially relevant in dMRI since noise can have a deleterious impact on both quantification accuracy and image preprocessing. The most successful me…
▽ More
We propose a novel approach to denoising diffusion magnetic resonance images (dMRI) using convolutional neural networks, that exploits the benefits of data acquired at multiple b-values to offset the need for many redundant observations. Denoising is especially relevant in dMRI since noise can have a deleterious impact on both quantification accuracy and image preprocessing. The most successful methods proposed to date, like Marchenko-Pastur Principal Component Analysis (MPPCA) denoising, are tailored to diffusion-weighting repeated for many encoding directions. They exploit high redundancy of the dataset that oversamples the diffusion-encoding direction space, since many directions have collinear components.
However, there are many dMRI techniques that do not entail a large number of encoding directions or repetitions, and are therefore less suited to this approach. For example, clinical dMRI exams may include as few as three encoding directions, with low or negligible data redundancy across directions. Moreover, promising new dMRI approaches, like spherical b-tensor encoding (STE), benefit from high b-values while sensitizing the signal to diffusion along all directions in just a single shot.
We introduce a convolutional neural network approach that we call multi-b-value-based denoising (MBD). MBD exploits the similarity in diffusion-weighted images (DWI) across different b-values but along the same diffusion encoding direction. It allows denoising of diffusion images with high noise variance while avoiding blurring, and using just a small number input images.
△ Less
Submitted 22 October, 2024;
originally announced October 2024.
-
Geometry of the cumulant series in neuroimaging
Authors:
Santiago Coelho,
Filip Szczepankiewicz,
Els Fieremans,
Dmitry S. Novikov
Abstract:
Water diffusion gives rise to micrometer-scale sensitivity of diffusion MRI (dMRI) to cellular-level tissue structure. The advent of precision medicine and quantitative imaging hinges on revealing the information content of dMRI, and providing its parsimonious basis- and hardware-independent "fingerprint". Here we reveal the geometry of a multi-dimensional dMRI signal, classify all 21 invariants o…
▽ More
Water diffusion gives rise to micrometer-scale sensitivity of diffusion MRI (dMRI) to cellular-level tissue structure. The advent of precision medicine and quantitative imaging hinges on revealing the information content of dMRI, and providing its parsimonious basis- and hardware-independent "fingerprint". Here we reveal the geometry of a multi-dimensional dMRI signal, classify all 21 invariants of diffusion and covariance tensors in terms of irreducible representations of the group of rotations, and relate them to tissue properties. Previously studied dMRI contrasts are expressed via 7 invariants, while the remaining 14 provide novel complementary information. We design acquisitions based on icosahedral vertices guaranteeing minimal number of measurements to determine 3-4 most used invariants in only 1-2 minutes for the whole brain. Representing dMRI signals via scalar invariant maps with definite symmetries will underpin machine learning classifiers of brain pathology, development, and aging, while fast protocols will enable translation of advanced dMRI into clinical practice.
△ Less
Submitted 4 September, 2024;
originally announced September 2024.
-
Assessment of Precision and Accuracy of Brain White Matter Microstructure using Combined Diffusion MRI and Relaxometry
Authors:
Santiago Coelho,
Ying Liao,
Filip Szczepankiewicz,
Jelle Veraart,
Sohae Chung,
Yvonne W. Lui,
Dmitry S. Novikov,
Els Fieremans
Abstract:
Joint modeling of diffusion and relaxation has seen growing interest due to its potential to provide complementary information about tissue microstructure. For brain white matter, we designed an optimal diffusion-relaxometry MRI protocol that samples multiple b-values, B-tensor shapes, and echo times (TE). This variable-TE protocol (27 min) has as subsets a fixed-TE protocol (15 min) and a 2-shell…
▽ More
Joint modeling of diffusion and relaxation has seen growing interest due to its potential to provide complementary information about tissue microstructure. For brain white matter, we designed an optimal diffusion-relaxometry MRI protocol that samples multiple b-values, B-tensor shapes, and echo times (TE). This variable-TE protocol (27 min) has as subsets a fixed-TE protocol (15 min) and a 2-shell dMRI protocol (7 min), both characterizing diffusion only. We assessed the sensitivity, specificity and reproducibility of these protocols with synthetic experiments and in six healthy volunteers. Compared with the fixed-TE protocol, the variable-TE protocol enables estimation of free water fractions while also capturing compartmental $T_2$ relaxation times. Jointly measuring diffusion and relaxation offers increased sensitivity and specificity to microstructure parameters in brain white matter with voxelwise coefficients of variation below 10%.
△ Less
Submitted 26 February, 2024;
originally announced February 2024.
-
Water exchange and microscopic kurtosis -- two sides of the same coin?
Authors:
Arthur Chakwizira,
Filip Szczepankiewicz,
Markus Nilsson
Abstract:
Diffusion MRI is sensitive to a wide range of features of the microstructure including diffusivity, exchange and three sources of diffusional kurtosis: isotropic, anisotropic, and microscopic. Correlation tensor imaging (CTI) uses double diffusion encoding (DDE) to resolve all three kurtosis components. In that framework, microscopic kurtosis is estimated from the contrast between SDE and parallel…
▽ More
Diffusion MRI is sensitive to a wide range of features of the microstructure including diffusivity, exchange and three sources of diffusional kurtosis: isotropic, anisotropic, and microscopic. Correlation tensor imaging (CTI) uses double diffusion encoding (DDE) to resolve all three kurtosis components. In that framework, microscopic kurtosis is estimated from the contrast between SDE and parallel DDE signals at the same b-value. Another approach is multi-Gaussian exchange (MGE), which can apply DDE to measure exchange. The highest exchange sensitivity in MGE is obtained by contrasting SDE and DDE signals at the same b-value. CTI and MGE can thus be applied to analyse the same data, but exchange can bias microscopic kurtosis estimates if not accounted for, and vice versa. Here, we develop new theory (MGE incorporating microscopic kurtosis, $μ$MGE) that accounts for both effects, by exploiting the distinct signatures of exchange and microscopic kurtosis with varying mixing time: exchange causes a dependence of the signal on mixing time while microscopic kurtosis does not. We perform Monte-Carlo simulations in different geometries with varying levels of exchange and study the behaviour of the parameters from CTI, MGE, and $μ$MGE. We conclude that microscopic kurtosis from CTI is positively biased by exchange. We also find that applying $μ$MGE to data acquired with multiple mixing times for both parallel and orthogonal DDE allows accurate estimation of exchange and all three sources of kurtosis.
△ Less
Submitted 25 March, 2024; v1 submitted 6 June, 2023;
originally announced June 2023.
-
Diffusion-weighted MR spectroscopy: consensus, recommendations and resources from acquisition to modelling
Authors:
Clémence Ligneul,
Chloé Najac,
André Döring,
Christian Beaulieu,
Francesca Branzoli,
William T Clarke,
Cristina Cudalbu,
Guglielmo Genovese,
Saad Jbabdi,
Ileana Jelescu,
Dimitrios Karampinos,
Roland Kreis,
Henrik Lundell,
Małgorzata Marjańska,
Harald E. Möller,
Jessie Mosso,
Eloïse Mougel,
Stefan Posse,
Stefan Ruschke,
Kadir Simsek,
Filip Szczepankiewicz,
Assaf Tal,
Chantal Tax,
Georg Oeltzschner,
Marco Palombo
, et al. (2 additional authors not shown)
Abstract:
Brain cell structure and function reflect neurodevelopment, plasticity and ageing, and changes can help flag pathological processes such as neurodegeneration and neuroinflammation. Accurate and quantitative methods to non-invasively disentangle cellular structural features are needed and are a substantial focus of brain research. Diffusion-weighted MR spectroscopy (dMRS) gives access to diffusion…
▽ More
Brain cell structure and function reflect neurodevelopment, plasticity and ageing, and changes can help flag pathological processes such as neurodegeneration and neuroinflammation. Accurate and quantitative methods to non-invasively disentangle cellular structural features are needed and are a substantial focus of brain research. Diffusion-weighted MR spectroscopy (dMRS) gives access to diffusion properties of endogenous intracellular brain metabolites that are preferentially located inside specific brain cell populations. Despite its great potential, dMRS remains a challenging technique on all levels: from the data acquisition to the analysis, quantification, modelling and interpretation of results. These challenges were the motivation behind the organisation of the Lorentz Workshop on 'Best Practices and Tools for Diffusion MR Spectroscopy' held in Leiden in September 2021. During the workshop, the dMRS community established a set of recommendations to execute robust dMRS studies. This paper provides a description of the steps needed for acquiring, processing, fitting and modelling dMRS data and provides links to useful resources.
△ Less
Submitted 18 May, 2023;
originally announced May 2023.
-
Diffusion MRI with free gradient waveforms on a high-performance gradient system: Probing restriction and exchange in the human brain
Authors:
Arthur Chakwizira,
Ante Zhu,
Thomas Foo,
Carl-Fredrik Westin,
Filip Szczepankiewicz,
Markus Nilsson
Abstract:
The dependence of the diffusion MRI signal on the diffusion time carries signatures of restricted diffusion and exchange. Here we seek to highlight these signatures in the human brain by performing experiments using free gradient waveforms that are selectively sensitive to the two effects. We examine six healthy volunteers using both strong and ultra-strong gradients (80, 200 and 300 mT/m). In an…
▽ More
The dependence of the diffusion MRI signal on the diffusion time carries signatures of restricted diffusion and exchange. Here we seek to highlight these signatures in the human brain by performing experiments using free gradient waveforms that are selectively sensitive to the two effects. We examine six healthy volunteers using both strong and ultra-strong gradients (80, 200 and 300 mT/m). In an experiment featuring a large set of gradient waveforms with different sensitivities to restricted diffusion and exchange (150 samples), our results reveal unique time-dependence signatures in grey and white matter, where the former is characterised by both restricted diffusion and exchange and the latter predominantly exhibits restricted diffusion. Furthermore, we show that gradient waveforms with independently varying sensitivities to restricted diffusion and exchange can be used to map exchange in the human brain. We consistently find that exchange in grey matter is at least twice as fast as in white matter, across all subjects and all gradient strengths. The shortest exchange times observed in this study were in the cerebellar cortex (115 ms). We also assess the feasibility of future clinical applications of the method used in this work, where we find that the grey-white matter exchange contrast obtained with a 25-minute 300 mT/m protocol is preserved by a 4-minute 300 mT/m and a 10-minute 80 mT/m protocol. Our work underlines the utility of free waveforms for detecting time-dependence signatures due to restricted diffusion and exchange in vivo, which may potentially serve as a tool for studying diseased tissue.
△ Less
Submitted 5 April, 2023;
originally announced April 2023.
-
Spherical convolutional neural networks can improve brain microstructure estimation from diffusion MRI data
Authors:
Leevi Kerkelä,
Kiran Seunarine,
Filip Szczepankiewicz,
Chris A. Clark
Abstract:
Diffusion magnetic resonance imaging is sensitive to the microstructural properties of brain tissue. However, estimating clinically and scientifically relevant microstructural properties from the measured signals remains a highly challenging inverse problem that machine learning may help solve. This study investigated if recently developed rotationally invariant spherical convolutional neural netw…
▽ More
Diffusion magnetic resonance imaging is sensitive to the microstructural properties of brain tissue. However, estimating clinically and scientifically relevant microstructural properties from the measured signals remains a highly challenging inverse problem that machine learning may help solve. This study investigated if recently developed rotationally invariant spherical convolutional neural networks can improve microstructural parameter estimation. We trained a spherical convolutional neural network to predict the ground-truth parameter values from efficiently simulated noisy data and applied the trained network to imaging data acquired in a clinical setting to generate microstructural parameter maps. Our network performed better than the spherical mean technique and multi-layer perceptron, achieving higher prediction accuracy than the spherical mean technique with less rotational variance than the multi-layer perceptron. Although we focused on a constrained two-compartment model of neuronal tissue, the network and training pipeline are generalizable and can be used to estimate the parameters of any Gaussian compartment model. To highlight this, we also trained the network to predict the parameters of a three-compartment model that enables the estimation of apparent neural soma density using tensor-valued diffusion encoding.
△ Less
Submitted 26 February, 2024; v1 submitted 17 November, 2022;
originally announced November 2022.
-
Probing restricted diffusion and exchange using free gradient waveforms: validation by numerical simulations
Authors:
Arthur Chakwizira,
Carl-Fredrik Westin,
Jan Brabec,
Samo Lasič,
Linda Knutsson,
Filip Szczepankiewicz,
Markus Nilsson
Abstract:
Monitoring time-dependence with diffusion MRI yields observables sensitive to compartment sizes (restricted diffusion) and membrane permeability (water exchange). However, restricted diffusion and exchange have opposite effects on the diffusion-weighted signal, which can confound parameter estimates. In this work, we present a signal representation that captures the effects of both restricted diff…
▽ More
Monitoring time-dependence with diffusion MRI yields observables sensitive to compartment sizes (restricted diffusion) and membrane permeability (water exchange). However, restricted diffusion and exchange have opposite effects on the diffusion-weighted signal, which can confound parameter estimates. In this work, we present a signal representation that captures the effects of both restricted diffusion and exchange up to second order in b-value and is compatible with gradient waveforms of arbitrary shape. The representation features mappings from a gradient waveform to two scalars that separately control the sensitivity to restriction and exchange. We demonstrate that these scalars span a two-dimensional space that can be used to choose waveforms that selectively probe restricted diffusion or exchange, in order to eliminate the correlation between the two phenomena. We found that waveforms with specific but unconventional shapes provide an advantage over conventional pulsed and oscillating gradient acquisitions. We also show that parametrisation of waveforms into a two-dimensional space can be used to understand protocols from other approaches that probe restricted diffusion and exchange. For example, we find that the variation of mixing time in filter-exchange imaging corresponds to variation of our exchange-weighting scalar at a fixed value of the restriction-weighting scalar. Numerical evaluation of the proposed signal representation using Monte Carlo simulations on a synthetic substrate showed that the theory is applicable to sizes in the range 2 - 7 micrometres and barrier-limited exchange in the range 0 - 20 s$^{-1}$. The presented theory constitutes a simple and intuitive description of how restricted diffusion and exchange influence the signal as well as how to design a protocol to separate the two effects.
△ Less
Submitted 22 November, 2021;
originally announced November 2021.
-
aDWI-BIDS: an extension to the brain imaging data structure for advanced diffusion weighted imaging
Authors:
James Gholam,
Filip Szczepankiewicz,
Chantal M. W. Tax,
Lars Mueller,
Emre Kopanoglu,
Markus Nilsson,
Santiago Aja-Fernandez,
Matt Griffin,
Derek K. Jones,
Leandro Beltrachini
Abstract:
Diffusion weighted imaging techniques permit us to infer microstructural detail in biological tissue in vivo and noninvasively. Modern sequences are based on advanced diffusion encoding schemes, allowing probing of more revealing measures of tissue microstructure than the standard apparent diffusion coefficient or fractional anisotropy. Though these methods may result in faster or more revealing a…
▽ More
Diffusion weighted imaging techniques permit us to infer microstructural detail in biological tissue in vivo and noninvasively. Modern sequences are based on advanced diffusion encoding schemes, allowing probing of more revealing measures of tissue microstructure than the standard apparent diffusion coefficient or fractional anisotropy. Though these methods may result in faster or more revealing acquisitions, they generally demand prior knowledge of sequence-specific parameters for which there is no accepted sharing standard. Here, we present a metadata labelling scheme suitable for the needs of developers and users within the diffusion neuroimaging community alike: a lightweight, unambiguous parametric map relaying acqusition parameters. This extensible scheme supports a wide spectrum of diffusion encoding methods, from single diffusion encoding to highly complex sequences involving arbitrary gradient waveforms. Built under the brain imaging data structure (BIDS), it allows storage of advanced diffusion MRI data comprehensively alongside any other neuroimaging information, facilitating processing pipelines and multimodal analyses. We illustrate the usefulness of this BIDS-extension with a range of example data, and discuss the extension's impact on pre- and post-processing software.
△ Less
Submitted 12 April, 2021; v1 submitted 26 March, 2021;
originally announced March 2021.
-
Gradient waveform design for tensor-valued encoding in diffusion MRI
Authors:
Filip Szczepankiewicz,
Carl-Fredrik Westin,
Markus Nilsson
Abstract:
Diffusion encoding along multiple spatial directions per signal acquisition can be described in terms of a b-tensor. The benefit of tensor-valued diffusion encoding is that it unlocks the "shape of the b-tensor" as a new encoding dimension. By modulating the b-tensor shape, we can control the sensitivity to microscopic diffusion anisotropy which can be used as a contrast mechanism; a feature that…
▽ More
Diffusion encoding along multiple spatial directions per signal acquisition can be described in terms of a b-tensor. The benefit of tensor-valued diffusion encoding is that it unlocks the "shape of the b-tensor" as a new encoding dimension. By modulating the b-tensor shape, we can control the sensitivity to microscopic diffusion anisotropy which can be used as a contrast mechanism; a feature that is inaccessible by conventional diffusion encoding. Since imaging methods based on tensor-valued diffusion encoding are finding an increasing number of applications we are prompted to highlight the challenge of designing the optimal gradient waveforms for any given application. In this review, we first establish the basic design objectives in creating field gradient waveforms for tensor-valued diffusion MRI. We also survey additional design considerations related to limitations imposed by hardware and physiology, potential confounding effects that cannot be captured by the b-tensor, and artifacts related to the diffusion encoding waveform. Throughout, we discuss the expected compromises and tradeoffs with an aim to establish a more complete understanding of gradient waveform design and its impact on accurate measurements and interpretations of data.
△ Less
Submitted 17 November, 2020; v1 submitted 15 July, 2020;
originally announced July 2020.
-
Resolving orientation-specific diffusion-relaxation features via Monte-Carlo density-peak clustering in heterogeneous brain tissue
Authors:
A. Reymbaut,
J. P. de Almeida Martins,
C. M. W. Tax,
F. Szczepankiewicz,
D. K. Jones,
D. Topgaard
Abstract:
Characterizing the properties and orientations of sub-voxel fiber populations, although essential to study white-matter architecture, microstructure and connectivity, remains one of the main challenges faced by the MRI microstructure community. While some progress has been made in overcoming this challenge using models, signal representations and tractography algorithms, these approaches are ultim…
▽ More
Characterizing the properties and orientations of sub-voxel fiber populations, although essential to study white-matter architecture, microstructure and connectivity, remains one of the main challenges faced by the MRI microstructure community. While some progress has been made in overcoming this challenge using models, signal representations and tractography algorithms, these approaches are ultimately limited by their key assumptions or by the lack of specificity of the diffusion signal alone. In order to alleviate these limitations, we combine diffusion-relaxation MR acquisitions incorporating tensor-valued diffusion encoding, Monte-Carlo signal inversions that extract non-parametric intra-voxel distributions of diffusion tensors and relaxation rates, and density-based clustering techniques. This new approach, called "Monte-Carlo density-peak clustering" (MC-DPC), first delineates clusters in the diffusion-orientation subspace of the fiber-like diffusion-relaxation components output by Monte-Carlo signal inversions and then draws from the statistical aspect of these inversion algorithms to compute the median and interquartile range of orientation-resolved means of diffusivities and relaxation rates. Evaluating MC-DPC on tensor-valued diffusion-encoded and T2-weighted correlated datasets in silico and in vivo, we demonstrate its ability to simultaneously capture sub-voxel fiber orientations and cones of uncertainty, and measure fiber-specific diffusion-relaxation properties that are consistent with the known anatomy and existing literature. Straightforwardly translatable to other diffusion-relaxation correlation experiments probing $T_1$ and $T_2^*$, MC-DPC shows potential in tracking bundle-specific patient-control group differences and longitudinal microstructural changes, enabling new tools for microstructure-informed tractography, and mapping tract-specific myelination states.
△ Less
Submitted 11 May, 2020; v1 submitted 18 April, 2020;
originally announced April 2020.
-
Magic DIAMOND: Multi-Fascicle Diffusion Compartment Imaging with Tensor Distribution Modeling and Tensor-Valued Diffusion Encoding
Authors:
A. Reymbaut,
A. Valcourt Caron,
G. Gilbert,
F. Szczepankiewicz,
M. Nilsson,
S. K. Warfield,
M. Descoteaux,
B. Scherrer
Abstract:
Diffusion tensor imaging provides increased sensitivity to microstructural tissue changes compared to conventional anatomical imaging but also presents limited specificity. To tackle this problem, the DIAMOND model subdivides the voxel content into diffusion compartments and draws from diffusion-weighted data to estimate compartmental non-central matrix-variate Gamma distribution of diffusion tens…
▽ More
Diffusion tensor imaging provides increased sensitivity to microstructural tissue changes compared to conventional anatomical imaging but also presents limited specificity. To tackle this problem, the DIAMOND model subdivides the voxel content into diffusion compartments and draws from diffusion-weighted data to estimate compartmental non-central matrix-variate Gamma distribution of diffusion tensors, thereby resolving crossing fascicles while accounting for their respective heterogeneity. Alternatively, tensor-valued diffusion encoding defines new acquisition schemes tagging specific features of the intra-voxel diffusion tensor distribution directly from the outcome of the measurement. However, the impact of such schemes on estimating brain microstructural features has only been studied in a handful of parametric single-fascicle models. In this work, we derive a general Laplace transform for the non-central matrix-variate Gamma distribution, which enables the extension of DIAMOND to tensor-valued encoded data. We then evaluate this "Magic DIAMOND" model in silico and in vivo on various combinations of tensor-valued encoded data. Assessing uncertainty on parameter estimation via stratified bootstrap, we investigate both voxel-based and fixel-based metrics by carrying out multi-peak tractography. We show that our estimated metrics can be mapped along tracks robustly across regions of fiber crossing, which opens new perspectives for tractometry and microstructure mapping along specific white-matter tracts.
△ Less
Submitted 17 April, 2020; v1 submitted 15 April, 2020;
originally announced April 2020.
-
Maxwell-compensated design of asymmetric gradient waveforms for tensor-valued diffusion encoding
Authors:
Filip Szczepankiewicz,
Carl-Fredrik Westin,
Markus Nilsson
Abstract:
Purpose: Asymmetric gradient waveforms are attractive for diffusion encoding due to their superior efficiency, however, the asymmetry may cause a residual gradient moment at the end of the encoding. Depending on the experiment setup, this residual moment may cause significant signal bias and image artifacts. The purpose of this study was to develop an asymmetric gradient waveform design for tensor…
▽ More
Purpose: Asymmetric gradient waveforms are attractive for diffusion encoding due to their superior efficiency, however, the asymmetry may cause a residual gradient moment at the end of the encoding. Depending on the experiment setup, this residual moment may cause significant signal bias and image artifacts. The purpose of this study was to develop an asymmetric gradient waveform design for tensor-valued diffusion encoding that is not affected by concomitant gradient. Methods: The Maxwell index was proposed as a scalar invariant that captures the effect of concomitant gradients and was constrained in the numerical optimization to 100 (mT/m)$^2$ms to yield Maxwell-compensated waveforms. The efficacy of this design was tested in an oil phantom, and in a healthy human brain. For reference, waveforms from literature were included in the analysis. Simulations were performed to investigate if the design was valid for a wide range of experiments and if it could predict the signal bias. Results: Maxwell-compensated waveforms showed no signal bias in oil or in the brain. By contrast, several waveforms from literature showed gross signal bias. In the brain, the bias was large enough to markedly affect both signal and parameter maps, and the bias could be accurately predicted by theory. Conclusion: Constraining the Maxwell index in the optimization of asymmetric gradient waveforms yields efficient tensor-valued encoding with concomitant gradients that have a negligible effect on the signal. This waveform design is especially relevant in combination with strong gradients, long encoding times, thick slices, simultaneous multi-slice acquisition and large/oblique FOVs.
△ Less
Submitted 8 March, 2019;
originally announced March 2019.
-
Tensor-valued diffusion MRI in under 3 minutes: An initial survey of microscopic anisotropy and tissue heterogeneity in intracranial tumors
Authors:
Markus Nilsson,
Filip Szczepankiewicz,
Jan Brabec,
Marie Taylor,
Carl-Fredrik Westin,
Alexandra Golby,
Danielle van Westen,
Pia C Sundgren
Abstract:
Purpose: To evaluate the feasibility of a 3-minute b-tensor encoding protocol for diffusion MRI-based assessment of the microscopic anisotropy and tissue heterogeneity in a wide range of intracranial tumors. Methods: B-tensor encoding was performed in 42 patients with intracranial tumors (gliomas, meningiomas, adenomas, metastases). Microscopic anisotropy and tissue heterogeneity were evaluated by…
▽ More
Purpose: To evaluate the feasibility of a 3-minute b-tensor encoding protocol for diffusion MRI-based assessment of the microscopic anisotropy and tissue heterogeneity in a wide range of intracranial tumors. Methods: B-tensor encoding was performed in 42 patients with intracranial tumors (gliomas, meningiomas, adenomas, metastases). Microscopic anisotropy and tissue heterogeneity were evaluated by estimating the anisotropic kurtosis ($MK_A$) and isotropic kurtosis ($MK_I$), respectively. An extensive imaging protocol was compared with a faster 3-minute protocol. Results: The fast imaging protocol yielded parameters with characteristics in terms of bias and precision similar to the full protocol. Glioblastomas had lower microscopic anisotropy than meningiomas $(MK_A = 0.29 \pm 0.06$ versus $0.45\pm0.08, p = 0.003)$. Metastases had higher tissue heterogeneity $(MK_I = 0.57\pm0.07)$ than both the glioblastomas $(0.44\pm0.06, p < 0.001)$ and meningiomas $(0.46\pm0.06, p = 0.03)$. Conclusion: Evaluation of the microscopic anisotropy and tissue heterogeneity in intracranial tumor patients is feasible in clinically relevant times frames.
△ Less
Submitted 26 February, 2019;
originally announced February 2019.
-
Improved fibre dispersion estimation using b-tensor encoding
Authors:
Michiel Cottaar,
Filip Szczepankiewicz,
Matteo Bastiani,
Moises Hernandez-Fernandez,
Stamatios N. Sotiropoulos,
Markus Nilsson,
Saad Jbabdi
Abstract:
Measuring fibre dispersion in white matter with diffusion magnetic resonance imaging (MRI) is limited by an inherent degeneracy between fibre dispersion and microscopic diffusion anisotropy (i.e., the diffusion anisotropy expected for a single fibre orientation). This means that estimates of fibre dispersion rely on strong assumptions, such as constant microscopic anisotropy throughout the white m…
▽ More
Measuring fibre dispersion in white matter with diffusion magnetic resonance imaging (MRI) is limited by an inherent degeneracy between fibre dispersion and microscopic diffusion anisotropy (i.e., the diffusion anisotropy expected for a single fibre orientation). This means that estimates of fibre dispersion rely on strong assumptions, such as constant microscopic anisotropy throughout the white matter or specific biophysical models. Here we present a simple approach for resolving this degeneracy using measurements that combine linear (conventional) and spherical tensor diffusion encoding.
To test the accuracy of the fibre dispersion when our microstructural model is only an approximation of the true tissue structure, we simulate multi-compartment data and fit this with a single-compartment model. For such overly simplistic tissue assumptions, we show that the bias in fibre dispersion is greatly reduced ($\sim$5x) for single-shell linear and spherical tensor encoding data compared with single-shell or multi-shell conventional data. In in-vivo data we find a consistent estimate of fibre dispersion as we reduce the b-value from 3 to 1.5 ms/$μ$m$^2$, increase the repetition time, increase the echo time, or increase the diffusion time. We conclude that the addition of spherical tensor encoded data to conventional linear tensor encoding data greatly reduces the sensitivity of the estimated fibre dispersion to the model assumptions of the tissue microstructure.
△ Less
Submitted 3 December, 2019; v1 submitted 17 January, 2019;
originally announced January 2019.
-
Searching for the neurite density with diffusion MRI: challenges for biophysical modeling
Authors:
Björn Lampinen,
Filip Szczepankiewicz,
Mikael Novén,
Danielle van Westen,
Oskar Hansson,
Elisabet Englund,
Johan Mårtensson,
Carl-Fredrik Westin,
Markus Nilsson
Abstract:
In vivo mapping of the neurite density with diffusion MRI (dMRI) is a high but challenging aim. First, it is unknown whether all neurites exhibit completely anisotropic ('stick-like') diffusion. Second, the 'density' of tissue components may be confounded by non-diffusion properties such as T2 relaxation. Third, the domain of validity for the estimated parameters to serve as indices of neurite den…
▽ More
In vivo mapping of the neurite density with diffusion MRI (dMRI) is a high but challenging aim. First, it is unknown whether all neurites exhibit completely anisotropic ('stick-like') diffusion. Second, the 'density' of tissue components may be confounded by non-diffusion properties such as T2 relaxation. Third, the domain of validity for the estimated parameters to serve as indices of neurite density is incompletely explored. We investigated these challenges by acquiring data with 'b-tensor encoding' and multiple echo times in both healthy brain and white matter lesions. Results showed that microscopic anisotropy from b-tensor data is associated with myelinated axons but not with dendrites. Furthermore, b-tensor and multi-echo data showed that unbiased density estimates in white matter lesions require data-driven estimates of compartment-specific T2 times. Finally, the 'stick' fractions of different biophysical models could generally not serve as neurite density indices across the healthy brain and white matter lesions, where outcomes of comparisons depended on the choice of constraints. In particular, constraining compartment-specific T2 times was ambiguous in the healthy brain and had a large impact on estimated values. In summary, estimating neurite density may require accounting for different diffusion and/or T2 properties between axons and dendrites. Constrained 'index' parameters could be valid within limited domains that should be delineated by future studies.
△ Less
Submitted 24 October, 2018; v1 submitted 7 June, 2018;
originally announced June 2018.
-
Whole-brain diffusional variance decomposition (DIVIDE): Demonstration of technical feasibility at clinical MRI systems
Authors:
Filip Szczepankiewicz,
Jens Sjölund,
Freddy Ståhlberg,
Jimmy Lätt,
Markus Nilsson
Abstract:
Purpose: To assess the technical feasibility of whole-brain diffusional variance decomposition (DIVIDE) based on q-space trajectory encoding (QTE) at clinical MRI systems with varying performance. DIVIDE is used to separate diffusional heterogeneity into components that arise due to isotropic and anisotropic tissue structures. Methods: We designed imaging protocols for DIVIDE using numerically opt…
▽ More
Purpose: To assess the technical feasibility of whole-brain diffusional variance decomposition (DIVIDE) based on q-space trajectory encoding (QTE) at clinical MRI systems with varying performance. DIVIDE is used to separate diffusional heterogeneity into components that arise due to isotropic and anisotropic tissue structures. Methods: We designed imaging protocols for DIVIDE using numerically optimized gradient waveforms for diffusion encoding. Imaging was performed at systems with magnetic field strengths between 1.5 and 7 T, and gradient amplitudes between 33 and 80 mT/m. Technical feasibility was assessed from signal characteristics and quality of parameter maps in a single volunteer scanned at all systems. Results: The technical feasibility of QTE and DIVIDE was demonstrated at all systems. The system with the highest performance allowed whole-brain DIVIDE at 2 mm isotropic voxels. The system with the lowest performance required a spatial resolution of 2.5x2.5x4 mm3 to yield a sufficient signal-to-noise ratio. Conclusions: Whole-brain DIVIDE based on QTE is feasible at the investigated MRI systems. This demonstration indicates that tissue features beyond those accessible by conventional diffusion encoding may be explored on a wide range of MRI systems.
△ Less
Submitted 20 December, 2016;
originally announced December 2016.