-
Investigating the Proton Structure: The FAMU experiment
Authors:
A. Vacchi,
A. Adamczak,
D. Bakalov,
G. Baldazzi,
M. Baruzzo,
R. Benocci,
R. Bertoni,
M. Bonesini,
H. Cabrera,
S. Carsi,
D. Cirrincione,
F. Chignoli,
M. Clemenza,
L. Colace,
M. Danailov,
P. Danev,
A. de Bari,
C. De Vecchi,
M. De Vincenzi,
E. Fasci,
K. S. Gadedjisso-Tossou,
L. Gianfrani,
A. D. Hillier,
K. Ishida,
P. J. C. King
, et al. (24 additional authors not shown)
Abstract:
The article gives the motivations for the measurement of the hyperfine splitting (hfs) in the ground state of muonic hydrogen to explore the properties of the proton at low momentum transfer. It summarizes these proposed measurement methods and finally describes the FAMU experiment in more detail.
The article gives the motivations for the measurement of the hyperfine splitting (hfs) in the ground state of muonic hydrogen to explore the properties of the proton at low momentum transfer. It summarizes these proposed measurement methods and finally describes the FAMU experiment in more detail.
△ Less
Submitted 8 March, 2024;
originally announced March 2024.
-
Measurement of the muon transfer rate from muonic hydrogen to oxygen in the range 70-336 K
Authors:
C. Pizzolotto,
A. Sbrizzi,
A. Adamczak,
D. Bakalov,
G. Baldazzi,
M. Baruzzo,
R. Benocci,
R. Bertoni,
M. Bonesini,
H. Cabrera,
D. Cirrincione,
M. Clemenza,
L. Colace,
M. Danailov,
P. Danev,
A. de Bari,
C. De Vecchio,
M. De Vincenzi,
E. Fasci,
F. Fuschino,
K. S. Gadedjisso-Tossou,
L. Gianfrani,
K. Ishida,
C. Labanti,
V. Maggi
, et al. (17 additional authors not shown)
Abstract:
The first measurement of the temperature dependence of the muon transfer rate from muonic hydrogen to oxygen was performed by the FAMU collaboration in 2016. The results provide evidence that the transfer rate rises with the temperature in the range 104-300 K. This paper presents the results of the experiment done in 2018 to extend the measurements towards lower (70 K) and higher (336 K) temperatu…
▽ More
The first measurement of the temperature dependence of the muon transfer rate from muonic hydrogen to oxygen was performed by the FAMU collaboration in 2016. The results provide evidence that the transfer rate rises with the temperature in the range 104-300 K. This paper presents the results of the experiment done in 2018 to extend the measurements towards lower (70 K) and higher (336 K) temperatures. The 2018 results confirm the temperature dependence of the muon transfer rate observed in 2016 and sets firm ground for comparison with the theoretical predictions.
△ Less
Submitted 14 May, 2021;
originally announced May 2021.
-
Laboratory tests for MIR light detection and transport with specialty optical fibres
Authors:
R. Benocci,
M. Bonesini,
K. S. Gadedjisso-Tossou,
H. Cabrera Morales,
L. Stoychev,
M. Rossella,
M. Baruzzo,
M. Consonni,
J. J. Suarez-Vargas
Abstract:
The FAMU (Fisica degli Atomi Muonici) experiment at the RIKEN RAL pulsed muon facility will measure the proton Zemach radius with high precision, thus contributing to the solution of the so-called proton radius puzzle. The situation is now confused and new measurements will help reduce the discrepancy as measured with electrons or muons. To this aim, FAMU will make use of a high-intensity pulsed m…
▽ More
The FAMU (Fisica degli Atomi Muonici) experiment at the RIKEN RAL pulsed muon facility will measure the proton Zemach radius with high precision, thus contributing to the solution of the so-called proton radius puzzle. The situation is now confused and new measurements will help reduce the discrepancy as measured with electrons or muons. To this aim, FAMU will make use of a high-intensity pulsed muon beam at RIKEN-RAL impinging on a cryogenic hydrogen target and a tunable Mid-infrared (MIR) laser emitting at around 6.78 um, to measure the hyperfine (HFS) splitting of the 1S state of muonic hydrogen. The injection of light into the cryogenic target and its monitoring via dedicated MIR sensors is an asset for the experiment. A possible solution is via specialty MIR fibres based on hollow core waveguides or polycrystalline fibres. Two dedicated setups based on pulsed QCL lasers, from Alpes Laser, emitting around 6.78 um have been used to study the fibre attenuation while the high energy laser developed at Elettra Sincrotrone in Trieste has been used to study the damage threshold at high energies. The alignment of MIR laser radiation into an optical cavity presents criticalities due to geometrical constraints. Its control requires the use of small and sensitive detectors. The results obtained with a quantum IR sensor with an integrated circuit for signal processing are reported.
△ Less
Submitted 20 April, 2020; v1 submitted 3 April, 2020;
originally announced April 2020.
-
First measurement of the temperature dependence of muon transfer rate from muonic hydrogen atoms to oxygen
Authors:
FAMU Collaboration,
E. Mocchiutti,
A. Adamczak,
D. Bakalov,
G. Baldazzi,
R. Benocci,
R. Bertoni,
M. Bonesini,
V. Bonvicini,
H. Cabrera Morales,
F. Chignoli,
M. Clemenza,
L. Colace,
M. Danailov,
P. Danev,
A. de Bari,
C. De Vecchi,
M. De Vincenzi,
E. Furlanetto,
F. Fuschino,
K. S. Gadedjisso-Tossou,
D. Guffanti,
K. Ishida,
C. Labanti,
V. Maggi
, et al. (17 additional authors not shown)
Abstract:
We report the first measurement of the temperature dependence of muon transfer rate from $μ$p atoms to oxygen between 100 and 300 K. Data were obtained from the X-ray spectra of delayed events in gaseous target H$_2$/O$_2$ exposed to a muon beam. Based on the data, we determined the muon transfer energy dependence up to 0.1 eV, showing an 8-fold increase in contrast with the predictions of constan…
▽ More
We report the first measurement of the temperature dependence of muon transfer rate from $μ$p atoms to oxygen between 100 and 300 K. Data were obtained from the X-ray spectra of delayed events in gaseous target H$_2$/O$_2$ exposed to a muon beam. Based on the data, we determined the muon transfer energy dependence up to 0.1 eV, showing an 8-fold increase in contrast with the predictions of constant rate in the low energy limit. This work set constraints on theoretical models of muon transfer, and is of fundamental importance for the measurement of the hyperfine splitting of $μ$p by the FAMU collaboration.
△ Less
Submitted 14 July, 2020; v1 submitted 6 May, 2019;
originally announced May 2019.
-
FAMU: study of the energy dependent transfer rate $Λ_{μp \rightarrow μO}$
Authors:
FAMU Collaboration,
E. Mocchiutti,
V. Bonvicini,
M. Danailov,
E. Furlanetto,
K. S. Gadedjisso-Tossou,
D. Guffanti,
C. Pizzolotto,
A. Rachevski,
L. Stoychev,
E. Vallazza,
G. Zampa,
J. Niemela,
K. Ishida,
A. Adamczak,
G. Baccolo,
R. Benocci,
R. Bertoni,
M. Bonesini,
F. Chignoli,
M. Clemenza,
A. Curioni,
V. Maggi,
R. Mazza,
M. Moretti
, et al. (31 additional authors not shown)
Abstract:
The main goal of the FAMU experiment is the measurement of the hyperfine splitting (hfs) in the 1S state of muonic hydrogen $ΔE_{hfs}(μ^-p)1S$. The physical process behind this experiment is the following: $μp$ are formed in a mixture of hydrogen and a higher-Z gas. When absorbing a photon at resonance-energy $ΔE_{hfs}\approx0.182$~eV, in subsequent collisions with the surrounding $H_2$ molecules,…
▽ More
The main goal of the FAMU experiment is the measurement of the hyperfine splitting (hfs) in the 1S state of muonic hydrogen $ΔE_{hfs}(μ^-p)1S$. The physical process behind this experiment is the following: $μp$ are formed in a mixture of hydrogen and a higher-Z gas. When absorbing a photon at resonance-energy $ΔE_{hfs}\approx0.182$~eV, in subsequent collisions with the surrounding $H_2$ molecules, the $μp$ is quickly de-excited and accelerated by $\sim2/3$ of the excitation energy. The observable is the time distribution of the K-lines X-rays emitted from the $μZ$ formed by muon transfer $(μp) +Z \rightarrow (μZ)^*+p$, a reaction whose rate depends on the $μp$ kinetic energy. The maximal response, to the tuned laser wavelength, of the time distribution of X-ray from K-lines of the $(μZ)^*$ cascade indicate the resonance. During the preparatory phase of the FAMU experiment, several measurements have been performed both to validate the methodology and to prepare the best configuration of target and detectors for the spectroscopic measurement. We present here the crucial study of the energy dependence of the transfer rate from muonic hydrogen to oxygen ($Λ_{μp \rightarrow μO}$), precisely measured for the first time.
△ Less
Submitted 22 January, 2019; v1 submitted 20 August, 2018;
originally announced August 2018.
-
First FAMU observation of muon transfer from mu-p atoms to higher-Z elements
Authors:
FAMU Collaboration,
Emiliano Mocchiutti,
Valter Bonvicini,
Rita Carbone,
Miltcho Danailov,
Elena Furlanetto,
Komlan Segbeya Gadedjisso-Tossou,
Daniele Guffanti,
Cecilia Pizzolotto,
Alexandre Rachevski,
Lyubomir Stoychev,
Erik Silvio Vallazza,
Gianluigi Zampa,
Joseph Niemela,
Katsuhiko Ishida,
Andrzej Adamczak,
Giovanni Baccolo,
Roberto Benocci,
Roberto Bertoni,
Maurizio Bonesini,
Francesco Chignoli,
Massimiliano Clemenza,
Alessandro Curioni,
Valter Maggi,
Roberto Mazza
, et al. (32 additional authors not shown)
Abstract:
The FAMU experiment aims to accurately measure the hyperfine splitting of the ground state of the muonic hydrogen atom. A measurement of the transfer rate of muons from hydrogen to heavier gases is necessary for this purpose. In June 2014, within a preliminary experiment, a pressurized gas-target was exposed to the pulsed low-energy muon beam at the RIKEN RAL muon facility (Rutherford Appleton Lab…
▽ More
The FAMU experiment aims to accurately measure the hyperfine splitting of the ground state of the muonic hydrogen atom. A measurement of the transfer rate of muons from hydrogen to heavier gases is necessary for this purpose. In June 2014, within a preliminary experiment, a pressurized gas-target was exposed to the pulsed low-energy muon beam at the RIKEN RAL muon facility (Rutherford Appleton Laboratory, UK). The main goal of the test was the characterization of both the noise induced by the pulsed beam and the X-ray detectors. The apparatus, to some extent rudimental, has served admirably to this task. Technical results have been published that prove the validity of the choices made and pave the way for the next steps. This paper presents the results of physical relevance of measurements of the muon transfer rate to carbon dioxide, oxygen, and argon from non-thermalized excited mu-p atoms. The analysis methodology and the approach to the systematics errors are useful for the subsequent study of the transfer rate as function of the kinetic energy of the mu-p currently under way.
△ Less
Submitted 15 December, 2017; v1 submitted 10 August, 2017;
originally announced August 2017.
-
Steps towards the hyperfine splitting measurement of the muonic hydrogen ground state: pulsed muon beam and detection system characterization
Authors:
A. Adamczak,
G. Baccolo,
D. Bakalov,
G. Baldazzi,
R. Bertoni,
M. Bonesini,
V. Bonvicini,
R. Campana,
R. Carbone,
T. Cervi,
F. Chignoli,
M. Clemenza,
L. Colace,
A. Curioni,
M. Danailov,
P. Danev,
I. D'Antone,
A. De,
C. De,
M. De,
M. Furini,
F. Fuschino,
K. Gadejisso-Tossou,
D. Guffanti,
A. Iaciofano
, et al. (30 additional authors not shown)
Abstract:
The high precision measurement of the hyperfine splitting of the muonic-hydrogen atom ground state with pulsed and intense muon beam requires careful technological choices both in the construction of a gas target and of the detectors. In June 2014, the pressurized gas target of the FAMU experiment was exposed to the low energy pulsed muon beam at the RIKEN RAL muon facility. The objectives of the…
▽ More
The high precision measurement of the hyperfine splitting of the muonic-hydrogen atom ground state with pulsed and intense muon beam requires careful technological choices both in the construction of a gas target and of the detectors. In June 2014, the pressurized gas target of the FAMU experiment was exposed to the low energy pulsed muon beam at the RIKEN RAL muon facility. The objectives of the test were the characterization of the target, the hodoscope and the X-ray detectors. The apparatus consisted of a beam hodoscope and X-rays detectors made with high purity Germanium and Lanthanum Bromide crystals. In this paper the experimental setup is described and the results of the detector characterization are presented.
△ Less
Submitted 21 June, 2016; v1 submitted 6 April, 2016;
originally announced April 2016.