CLIC Wake Field Monitor as a detuned Cavity Beam Position Monitor: Explanation of center offset between TE and TM channels in the TD26 structure
Authors:
Kyrre Ness Sjobak,
Hikmet Bursali,
Antonio Gillardi,
Reidar Lillestøl,
Wilfrid Farabolini,
Steffen Doebert,
Erik Adli,
Nuria Catalan Lasheras,
Roberto Corsini
Abstract:
The Wake Field Monitor (WFM) system installed on the CLIC prototype accelerating structure in CERN Linear Accelerator for Research (CLEAR) has two channels for each horizontal/vertical plane, operating at different frequencies. When moving the beam relative to the aperture of the structure, a disagreement is observed between the center position of the structure as measured with the two channels in…
▽ More
The Wake Field Monitor (WFM) system installed on the CLIC prototype accelerating structure in CERN Linear Accelerator for Research (CLEAR) has two channels for each horizontal/vertical plane, operating at different frequencies. When moving the beam relative to the aperture of the structure, a disagreement is observed between the center position of the structure as measured with the two channels in each plane. This is a challenge for the planned use of WFMs in the Compact Linear Collider (CLIC), where they will be used to measure the center offset between the accelerating structures and the beam. Through a mixture of simulations and measurements, we have discovered a potential mechanism for this, which is discussed along with implications for improving position resolution near the structure center, and the possibility determination of the sign of the beam offset.
△ Less
Submitted 13 July, 2023;
originally announced July 2023.
-
Beam Delivery and Beamstrahlung Considerations for Ultra-High Energy Linear Colliders
Authors:
Tim Barklow,
Spencer Gessner,
Mark Hogan,
Cho-Kuen Ng,
Michael Peskin,
Tor Raubenheimer,
Glen White,
Erik Adli,
Gevy Jiawei Cao,
Carl A. Lindstrom,
Kyrre Sjobak,
Sam Barber,
Cameron Geddes,
Arianna Formenti,
Remi Lehe,
Carl Schroeder,
Davide Terzani,
Jeroen van Tilborg,
Jean-Luc Vay,
Edoardo Zoni,
Chris Doss,
Michael Litos,
Ihar Lobach,
John Power,
Maximilian Swiatlowski
, et al. (5 additional authors not shown)
Abstract:
As part of the Snowmass'21 community planning excercise, the Advanced Accelerator Concepts (AAC) community proposed future linear colliders with center-of-mass energies up to 15 TeV and luminosities up to 50$\times10^{34}$ cm$^{-2}$s$^{-1}$ in a compact footprint. In addition to being compact, these machines must also be energy efficient. We identify two challenges that must be addressed in the de…
▽ More
As part of the Snowmass'21 community planning excercise, the Advanced Accelerator Concepts (AAC) community proposed future linear colliders with center-of-mass energies up to 15 TeV and luminosities up to 50$\times10^{34}$ cm$^{-2}$s$^{-1}$ in a compact footprint. In addition to being compact, these machines must also be energy efficient. We identify two challenges that must be addressed in the design of these machines. First, the Beam Delivery System (BDS) must not add significant length to the accelerator complex. Second, beam parameters must be chosen to mitigate beamstrahlung effects and maximize the luminosity-per-power of the machine. In this paper, we review advances in plasma lens technology that will help to reduce the length of the BDS system and we detail new Particle-in-Cell simulation studies that will provide insight into beamstrahlung mitigation techniques. We apply our analysis to both $e^+e^-$ and $γγ$ colliders.
△ Less
Submitted 31 May, 2023; v1 submitted 30 April, 2023;
originally announced May 2023.
-
Sharp dose profiles for high precision proton therapy using focused proton beams
Authors:
Fardous Reaz,
Kyrre Ness Sjobak,
Eirik Malinen,
Nina Frederike Jeppesen Edin,
Erik Adli
Abstract:
Proton beam therapy has been developed to irradiate the tumor with higher precision and dose conformity compared to conventional X-ray irradiation. The dose conformity of this treatment modality may be further improved if narrower proton beams are used. Still, this is limited by multiple Coulomb scattering of protons through tissue. The primary aim of this work was to develop techniques to produce…
▽ More
Proton beam therapy has been developed to irradiate the tumor with higher precision and dose conformity compared to conventional X-ray irradiation. The dose conformity of this treatment modality may be further improved if narrower proton beams are used. Still, this is limited by multiple Coulomb scattering of protons through tissue. The primary aim of this work was to develop techniques to produce narrow proton beams and investigate the resulting dose profiles. We introduced and assessed three different proton beam shaping techniques: 1) metal collimators (100/150~MeV), 2) focusing of conventional- (100/150~MeV), and 3) focusing of high-energy (350~MeV, shoot-through) proton beams. Focusing was governed by the initial value of the Twiss parameter $α$~($α_0$), and can be implemented with magnetic particle accelerator optics. The dose distributions in water were calculated by Monte Carlo simulations using Geant4, and evaluated by target to surface dose ratio (TSDR) in addition to the transverse beam size~($σ_T$) at the target. The target was defined as the location of the Bragg peak or the focal point. The different techniques showed greatly differing dose profiles, where focusing gave pronouncedly higher relative target dose and efficient use of primary protons. Metal collimators with radii < 2~mm gave low TSDRs (<~0.7) and large $σ_T$(>~3.6~mm). In contrast, a focused beam of conventional (150~MeV) energy produced a very high TSDR (>~80) with similar $σ_T$ as a collimated beam. High-energy focused beams were able to produce TSDRs > 100 and $σ_T$ around 1.5~mm. From this study, it appears very attractive to implement magnetically focused proton beams in radiotherapy of small lesions or tumors in close vicinity to healthy organs at risk. This can also lead to a paradigm change in spatially fractionated radiotherapy.
△ Less
Submitted 2 September, 2022;
originally announced September 2022.
-
Witness electron beam injection using an active plasma lens for a proton beam-driven plasma wakefield accelerator
Authors:
S. -Y. Kim,
K. Moon,
M. Chung,
K. N. Sjobak,
E. Adli,
S. Doebert,
M. Dayyani,
E. S. Yoon,
I. Nam,
G. Hahn
Abstract:
An active plasma lens focuses the beam in both the horizontal and vertical planes simultaneously using a magnetic field generated by a discharge current through the plasma. A beam size of 5--10 $μ$m can be achieved within a short distance using a focusing gradient on the order of 100 T/m. The active plasma lens is therefore an attractive element for plasma wakefield acceleration, because an ultra-…
▽ More
An active plasma lens focuses the beam in both the horizontal and vertical planes simultaneously using a magnetic field generated by a discharge current through the plasma. A beam size of 5--10 $μ$m can be achieved within a short distance using a focusing gradient on the order of 100 T/m. The active plasma lens is therefore an attractive element for plasma wakefield acceleration, because an ultra-small size of the witness electron beam is required for injection into the plasma wakefield to minimize emittance growth and to enhance the capturing efficiency. When the drive beam and witness electron beam co-propagate through the active plasma lens, interactions between the drive and witness beams, and the plasma must be considered. In this paper, through particle-in-cell simulations, we discuss the possibility of using an active plasma lens for the final focusing of the electron beam for the AWAKE RUN 2 experiments. It is confirmed that the amplitude of the plasma wakefield excited by proton bunches remains the same even after propagation through the active plasma lens. The emittance of the witness electron beam increases rapidly in the plasma density ramp regions of the lens. Nevertheless, when the witness electron beam has a charge of 100 pC, emittance of 10 mm mrad, and bunch length of 60 $μ$m, its emittance growth is not significant along the active plasma lens. For small emittance, such as 2 mm mrad, the emittance growth is found to be strongly dependent on the RMS beam size, plasma density, and multiple Coulomb scattering.
△ Less
Submitted 10 December, 2021; v1 submitted 20 April, 2021;
originally announced April 2021.
-
Multi-kT/m Focusing Gradient in a Linear Active Plasma Lens
Authors:
K. N. Sjobak,
E. Adli,
R. Corsini,
W. Farabolini,
G. Boyle,
C. A. Lindstrøm,
M. Meisel,
J. Osterhoff,
J. -H. Röckemann,
L. Schaper,
A. E. Dyson
Abstract:
Active plasma lenses are compact devices developed as a promising beam-focusing alternative for charged particle beams, capable of short focal lengths for high-energy beams. We have previously shown that linear magnetic fields with gradients of around 0.3 kT/m can be achieved in argon-filled plasma lenses that preserve beam emittance [C.A. Lindstrøm et al., Phys. Rev. Lett. 121, 194801 (2018)]. He…
▽ More
Active plasma lenses are compact devices developed as a promising beam-focusing alternative for charged particle beams, capable of short focal lengths for high-energy beams. We have previously shown that linear magnetic fields with gradients of around 0.3 kT/m can be achieved in argon-filled plasma lenses that preserve beam emittance [C.A. Lindstrøm et al., Phys. Rev. Lett. 121, 194801 (2018)]. Here we show that with argon in a 500 μm diameter capillary, the fields are still linear with a focusing gradient of 3.6 kT/m, which is an order of magnitude higher than the gradients of quadrupole magnets. The current pulses that generate the magnetic field are provided by compact Marx banks, and are highly repeatable. These results establish active plasma lenses as an ideal device for pulsed particle beam applications requiring very high focusing gradients that are uniform throughout the lens aperture.
△ Less
Submitted 19 December, 2020;
originally announced December 2020.
-
Dynamic coupling between particle-in-cell and atomistic simulations
Authors:
Mihkel Veske,
Andreas Kyritsakis,
Kyrre Ness Sjobak,
Vahur Zadin,
Alvo Aabloo,
Flyura Djurabekova
Abstract:
We propose a method to directly couple molecular dynamics, finite element method and particle-in-cell techniques to simulate metal surface response to high electric fields. We use this method to simulate the evolution of a field emitting tip under thermal runaway by fully including the 3D space-charge effects. We also present a comparison of the runaway process between the two tip geometries of di…
▽ More
We propose a method to directly couple molecular dynamics, finite element method and particle-in-cell techniques to simulate metal surface response to high electric fields. We use this method to simulate the evolution of a field emitting tip under thermal runaway by fully including the 3D space-charge effects. We also present a comparison of the runaway process between the two tip geometries of different widths. The results show with high statistical significance that in case of sufficiently narrow field emitters, the thermal runaway occurs in cycles where intensive neutral evaporation alternates with the cooling periods. The comparison with previous works shows, that the evaporation rate in the regime of intensive evaporation is sufficient to ignite a plasma arc above the simulated field emitters.
△ Less
Submitted 24 May, 2020; v1 submitted 19 June, 2019;
originally announced June 2019.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
Prediction of Beam Losses during Crab Cavity Quenches at the HL-LHC
Authors:
Robert Apsimon,
Graeme Burt,
Amos Dexter,
Nick Shipman,
Philippe Baudrenghien,
Rama Calaga,
Alejandro Castilla,
Alick Macpherson,
Kyrre Ness Sjobak,
Andrea Santamaria Garcia,
Niall Stapley,
Androula Alekou,
Robert Appleby
Abstract:
Studies of the crab cavities at KEKB revealed that the RF phase could shift by up to 50o within ~50 us during a quench; while the cavity voltage is still at approximately 75% of its nominal amplitude. If such a failure were to occur on the HL-LHC crab cavities, it is likely that the machine would sustain substantial damage to the beam line and surrounding infrastructure due to uncontrolled beam lo…
▽ More
Studies of the crab cavities at KEKB revealed that the RF phase could shift by up to 50o within ~50 us during a quench; while the cavity voltage is still at approximately 75% of its nominal amplitude. If such a failure were to occur on the HL-LHC crab cavities, it is likely that the machine would sustain substantial damage to the beam line and surrounding infrastructure due to uncontrolled beam loss before the machine protection system could dump the beam. We have developed a low-level RF system model, including detuning mechanisms and beam loading, and use this to simulate the behaviour of a crab cavity during a quench, modeling the low-level RF system, detuning mechanisms and beam loading. We supplement this with measurement data of the actual RF response of the proof of principle Double-Quarter Wave Crab Cravity during a quench. Extrapolating these measurements to the HL-LHC, we show that Lorentz Force detuning is the dominant effect leading to phase shifts in the crab cavity during quenches; rather than pressure detuning which is expected to be dominant for the KEKB crab cavities. The total frequency shift for the HL-LHC crab cavities during quenches is expected to be about 460 Hz, leading to a phase shift of no more than 3o. The results of the quench model are read into a particle tracking simulation, SixTrack, and used to determine the effect of quenches on the HL-LHC beam. The quench model has been benchmarked against the KEKB experimental measurements. In this paper we present the results of the simulations on a crab cavity failure for HL-LHC as well as for the SPS and show that beam loss is negligible when using a realistic low-level RF response.
△ Less
Submitted 4 December, 2018;
originally announced December 2018.
-
Dynamic simulations in SixTrack
Authors:
K. Sjobak,
V. K. Berglyd Olsen,
R. De Maria,
M. Fitterer,
A. Santamaría García,
H. Garcia-Morales,
A. Mereghetti,
J. F. Wagner,
S. J. Wretborn
Abstract:
The DYNK module allows element settings in SixTrack to be changed on a turn-by-turn basis. This document contains a technical description of the DYNK module in SixTrack. It is mainly intended for a developer or advanced user who wants to modify the DYNK module, for example by adding more functions that can be used to calculate new element settings, or to add support for new elements that can be us…
▽ More
The DYNK module allows element settings in SixTrack to be changed on a turn-by-turn basis. This document contains a technical description of the DYNK module in SixTrack. It is mainly intended for a developer or advanced user who wants to modify the DYNK module, for example by adding more functions that can be used to calculate new element settings, or to add support for new elements that can be used with DYNK.
△ Less
Submitted 19 August, 2018;
originally announced August 2018.
-
Emittance Preservation in an Aberration-Free Active Plasma Lens
Authors:
C. A. Lindstrøm,
E. Adli,
G. Boyle,
R. Corsini,
A. E. Dyson,
W. Farabolini,
S. M. Hooker,
M. Meisel,
J. Osterhoff,
J. -H. Röckemann,
L. Schaper,
K. N. Sjobak
Abstract:
Active plasma lensing is a compact technology for strong focusing of charged particle beams, which has gained considerable interest for use in novel accelerator schemes. While providing kT/m focusing gradients, active plasma lenses can have aberrations caused by a radially nonuniform plasma temperature profile, leading to degradation of the beam quality. We present the first direct measurement of…
▽ More
Active plasma lensing is a compact technology for strong focusing of charged particle beams, which has gained considerable interest for use in novel accelerator schemes. While providing kT/m focusing gradients, active plasma lenses can have aberrations caused by a radially nonuniform plasma temperature profile, leading to degradation of the beam quality. We present the first direct measurement of this aberration, consistent with theory, and show that it can be fully suppressed by changing from a light gas species (helium) to a heavier gas species (argon). Based on this result, we demonstrate emittance preservation for an electron beam focused by an argon-filled active plasma lens.
△ Less
Submitted 23 November, 2018; v1 submitted 10 August, 2018;
originally announced August 2018.
-
Overview of the CLEAR plasma lens experiment
Authors:
C. A. Lindstrøm,
K. N. Sjobak,
E. Adli,
J. -H. Röckemann,
L. Schaper,
J. Osterhoff,
A. E. Dyson,
S. M. Hooker,
W. Farabolini,
D. Gamba,
R. Corsini
Abstract:
Discharge capillary-based active plasma lenses are a promising new technology for strongly focusing charged particle beams, especially when combined with novel high gradient acceleration methods. Still, many questions remain concerning such lenses, including their transverse field uniformity, limitations due to plasma wakefields and whether they can be combined in multi-lens lattices in a way to c…
▽ More
Discharge capillary-based active plasma lenses are a promising new technology for strongly focusing charged particle beams, especially when combined with novel high gradient acceleration methods. Still, many questions remain concerning such lenses, including their transverse field uniformity, limitations due to plasma wakefields and whether they can be combined in multi-lens lattices in a way to cancel chromaticity. These questions will be addressed in a new plasma lens experiment at the CLEAR User Facility at CERN. All the subsystems have been constructed, tested and integrated into the CLEAR beam line, and are ready for experiments starting late 2017.
△ Less
Submitted 8 February, 2018; v1 submitted 3 January, 2018;
originally announced January 2018.
-
Updated baseline for a staged Compact Linear Collider
Authors:
The CLIC,
CLICdp collaborations,
:,
M. J. Boland,
U. Felzmann,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
C. Balazs,
T. K. Charles,
K. Afanaciev,
I. Emeliantchik,
A. Ignatenko,
V. Makarenko,
N. Shumeiko,
A. Patapenka,
I. Zhuk,
A. C. Abusleme Hoffman,
M. A. Diaz Gutierrez,
M. Vogel Gonzalez,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu
, et al. (493 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-q…
▽ More
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of centre-of-mass energy and it targets optimal physics output based on the current physics landscape. The optimised staging scenario foresees three main centre-of-mass energy stages at 380 GeV, 1.5 TeV and 3 TeV for a full CLIC programme spanning 22 years. For the first stage, an alternative to the CLIC drive beam scheme is presented in which the main linac power is produced using X-band klystrons.
△ Less
Submitted 27 March, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
Test Beam Results of 3D Silicon Pixel Sensors for the ATLAS upgrade
Authors:
ATLAS 3D Collaboration,
P. Grenier,
G. Alimonti,
M. Barbero,
R. Bates,
E. Bolle,
M. Borri,
M. Boscardin,
C. Buttar,
M. Capua,
M. Cavalli-Sforza,
M. Cobal,
A. Cristofoli,
G-F. Dalla Betta,
G. Darbo,
C. Da Vià,
E. Devetak,
B. DeWilde,
B. Di Girolamo,
D. Dobos,
K. Einsweiler,
D. Esseni,
S. Fazio,
C. Fleta,
J. Freestone
, et al. (68 additional authors not shown)
Abstract:
Results on beam tests of 3D silicon pixel sensors aimed at the ATLAS Insertable-B-Layer and High Luminosity LHC (HL-LHC)) upgrades are presented. Measurements include charge collection, tracking efficiency and charge sharing between pixel cells, as a function of track incident angle, and were performed with and without a 1.6 T magnetic field oriented as the ATLAS Inner Detector solenoid field. Sen…
▽ More
Results on beam tests of 3D silicon pixel sensors aimed at the ATLAS Insertable-B-Layer and High Luminosity LHC (HL-LHC)) upgrades are presented. Measurements include charge collection, tracking efficiency and charge sharing between pixel cells, as a function of track incident angle, and were performed with and without a 1.6 T magnetic field oriented as the ATLAS Inner Detector solenoid field. Sensors were bump bonded to the front-end chip currently used in the ATLAS pixel detector. Full 3D sensors, with electrodes penetrating through the entire wafer thickness and active edge, and double-sided 3D sensors with partially overlapping bias and read-out electrodes were tested and showed comparable performance.
△ Less
Submitted 21 January, 2011;
originally announced January 2011.
-
Preliminary results of 3D-DDTC pixel detectors for the ATLAS upgrade
Authors:
A. La Rosa,
M. Boscardin,
G. -F. Dalla Betta,
G. Darbo,
C. Gemme,
H. Pernegger,
C. Piemonte,
M. Povoli,
S. Ronchin,
A. Zoboli,
N. Zorzi,
E. Bolle,
M. Borri,
C. Da Via,
S. Dong,
S. Fazio,
P. Grenier,
S. Grinstein,
H. Gjersdal,
P. Hansson,
F. Huegging,
P. Jackson,
M. Kocian,
F. Rivero,
O. Rohne
, et al. (7 additional authors not shown)
Abstract:
3D Silicon sensors fabricated at FBK-irst with the Double-side Double Type Column (DDTC) approach and columnar electrodes only partially etched through p-type substrates were tested in laboratory and in a 1.35 Tesla magnetic field with a 180GeV pion beam at CERN SPS. The substrate thickness of the sensors is about 200um, and different column depths are available, with overlaps between junction c…
▽ More
3D Silicon sensors fabricated at FBK-irst with the Double-side Double Type Column (DDTC) approach and columnar electrodes only partially etched through p-type substrates were tested in laboratory and in a 1.35 Tesla magnetic field with a 180GeV pion beam at CERN SPS. The substrate thickness of the sensors is about 200um, and different column depths are available, with overlaps between junction columns (etched from the front side) and ohmic columns (etched from the back side) in the range from 110um to 150um. The devices under test were bump bonded to the ATLAS Pixel readout chip (FEI3) at SELEX SI (Rome, Italy). We report leakage current and noise measurements, results of functional tests with Am241 gamma-ray sources, charge collection tests with Sr90 beta-source and an overview of preliminary results from the CERN beam test.
△ Less
Submitted 20 October, 2009;
originally announced October 2009.