-
Quantifying errors of the electron-proton/muon correlation functionals through the Kohn-Sham inversion of a two-component model system
Authors:
Nahid Sadat Riyahi,
Mohammad Goli,
Shant Shahbazian
Abstract:
The multi-component density functional theory is faced with the challenge of capturing various types of inter- and intra-particle exchange-correlation effects beyond those introduced by the conventional electronic exchange-correlation functionals. Herein, we focus on evaluating the electron-proton/muon correlation functionals appearing in molecular/condensed-phase systems where a proton/muon is tr…
▽ More
The multi-component density functional theory is faced with the challenge of capturing various types of inter- and intra-particle exchange-correlation effects beyond those introduced by the conventional electronic exchange-correlation functionals. Herein, we focus on evaluating the electron-proton/muon correlation functionals appearing in molecular/condensed-phase systems where a proton/muon is treated as a quantum particle on equal footing with electrons, beyond the Born-Oppenheimer paradigm. Five recently developed local correlation functionals, i.e., the epc series and e$μ$c-1, are selected and their performances are analyzed by employing a two-particle model that includes an electron and a positively charged particle (PCP) with a variable mass, interacting through Coulombic forces, within a double harmonic trap. Using the Kohn-Sham (KS) inversion procedure, the exact two-component KS characterization of the model is deduced and its properties are compared to those derived from the considered functionals. The analysis demonstrates that these local functionals achieve their original parameterization objectives to reproduce the one-PCP densities and the electron-PCP correlation energies, but all fall short of reproducing the underlying PCP correlation potentials correctly. Moreover, a comprehensive error analysis reveals that the density-driven errors have a non-negligible contribution to the success of the considered functionals. Overall, the study shows the strengths as well as shortcomings of the considered functionals hopefully paving the way for designing more robust functionals in the future.
△ Less
Submitted 17 December, 2023; v1 submitted 3 October, 2023;
originally announced October 2023.
-
Comment on "Two-component density functional theory study of quantized muons in solids"
Authors:
Mohammad Goli,
Nahid Sadat Riyahi,
Shant Shahbazian
Abstract:
In [Phys. Rev. B 107, 094433 (2023)], Deng et al. have proposed an electron-muon correlation functional within the context of the two-component density functional theory (TC-DFT) for crystals/molecules containing positively charged muons. In order to verify its performance, we applied the functional in conjunction with the B3LYP, as a hybrid electronic exchange-correlation functional, to a benchma…
▽ More
In [Phys. Rev. B 107, 094433 (2023)], Deng et al. have proposed an electron-muon correlation functional within the context of the two-component density functional theory (TC-DFT) for crystals/molecules containing positively charged muons. In order to verify its performance, we applied the functional in conjunction with the B3LYP, as a hybrid electronic exchange-correlation functional, to a benchmark set of molecules. The results demonstrate that the proposed functional is not capable of reproducing the correct one-muon densities as well as some other key properties like muon's kinetic energy, the total energies and the mean muonic bond lengths. Using the muonium atom in a double-harmonic trap as a model we also demonstrate that the successful reproduction of the electron-muon contact hyperfine coupling constants by Deng et al. is probably the result of error cancellations. We also discuss some theoretical intricacies with the very definition of the electron-muon correlation energy within the context of the TC-DFT that must be taken into account in future efforts to design electron-muon correlation functionals.
△ Less
Submitted 27 April, 2024; v1 submitted 6 September, 2023;
originally announced September 2023.
-
Comparison of Patch-Based Conditional Generative Adversarial Neural Net Models with Emphasis on Model Robustness for Use in Head and Neck Cases for MR-Only planning
Authors:
Peter Klages,
Ilyes Benslimane,
Sadegh Riyahi,
Jue Jiang,
Margie Hunt,
Joe Deasy,
Harini Veeraraghavan,
Neelam Tyagi
Abstract:
A total of twenty paired CT and MR images were used in this study to investigate two conditional generative adversarial networks, Pix2Pix, and Cycle GAN, for generating synthetic CT images for Headand Neck cancer cases. Ten of the patient cases were used for training and included such common artifacts as dental implants; the remaining ten testing cases were used for testing and included a larger r…
▽ More
A total of twenty paired CT and MR images were used in this study to investigate two conditional generative adversarial networks, Pix2Pix, and Cycle GAN, for generating synthetic CT images for Headand Neck cancer cases. Ten of the patient cases were used for training and included such common artifacts as dental implants; the remaining ten testing cases were used for testing and included a larger range of image features commonly found in clinical head and neck cases. These features included strong metal artifacts from dental implants, one case with a metal implant, and one case with abnormal anatomy. The original CT images were deformably registered to the mDixon FFE MR images to minimize the effects of processing the MR images. The sCT generation accuracy and robustness were evaluated using Mean Absolute Error (MAE) based on the Hounsfield Units (HU) for three regions (whole body, bone, and air within the body), Mean Error (ME) to observe systematic average offset errors in the sCT generation, and dosimetric evaluation of all clinically relevant structures. For the test set the MAE for the Pix2Pix and Cycle GAN models were 92.4 $\pm$ 13.5 HU, and 100.7 $\pm$ 14.6 HU, respectively, for the body region, 166.3 $\pm$ 31.8 HU, and 184 $\pm$ 31.9 HU, respectively, for the bone region, and 183.7 $\pm$ 41.3 HU and 185.4 $\pm$ 37.9 HU for the air regions. The ME for Pix2Pix and Cycle GAN were 21.0 $\pm$ 11.8 HU and 37.5 $\pm$ 14.9 HU, respectively. Absolute Percent Mean/Max Dose Errors were less than 2% for the PTV and all critical structures for both models, and DRRs generated from these models looked qualitatively similar to CT generated DRRs showing these methods are promising for MR-only planning.
△ Less
Submitted 27 February, 2019; v1 submitted 1 February, 2019;
originally announced February 2019.
-
Quantification of Local Metabolic Tumor Volume Changes by Registering Blended PET-CT Images for Prediction of Pathologic Tumor Response
Authors:
Sadegh Riyahi,
Wookjin Choi,
Chia-Ju Liu,
Saad Nadeem,
Shan Tan,
Hualiang Zhong,
Wengen Chen,
Abraham J. Wu,
James G. Mechalakos,
Joseph O. Deasy,
Wei Lu
Abstract:
Quantification of local metabolic tumor volume (MTV) chan-ges after Chemo-radiotherapy would allow accurate tumor response evaluation. Currently, local MTV changes in esophageal (soft-tissue) cancer are measured by registering follow-up PET to baseline PET using the same transformation obtained by deformable registration of follow-up CT to baseline CT. Such approach is suboptimal because PET and C…
▽ More
Quantification of local metabolic tumor volume (MTV) chan-ges after Chemo-radiotherapy would allow accurate tumor response evaluation. Currently, local MTV changes in esophageal (soft-tissue) cancer are measured by registering follow-up PET to baseline PET using the same transformation obtained by deformable registration of follow-up CT to baseline CT. Such approach is suboptimal because PET and CT capture fundamentally different properties (metabolic vs. anatomy) of a tumor. In this work we combined PET and CT images into a single blended PET-CT image and registered follow-up blended PET-CT image to baseline blended PET-CT image. B-spline regularized diffeomorphic registration was used to characterize the large MTV shrinkage. Jacobian of the resulting transformation was computed to measure the local MTV changes. Radiomic features (intensity and texture) were then extracted from the Jacobian map to predict pathologic tumor response. Local MTV changes calculated using blended PET-CT registration achieved the highest correlation with ground truth segmentation (R=0.88) compared to PET-PET (R=0.80) and CT-CT (R=0.67) registrations. Moreover, using blended PET-CT registration, the multivariate prediction model achieved the highest accuracy with only one Jacobian co-occurrence texture feature (accuracy=82.3%). This novel framework can replace the conventional approach that applies CT-CT transformation to the PET data for longitudinal evaluation of tumor response.
△ Less
Submitted 24 August, 2018;
originally announced August 2018.
-
Reproducible and Interpretable Spiculation Quantification for Lung Cancer Screening
Authors:
Wookjin Choi,
Saad Nadeem,
Sadegh Riyahi,
Joseph O. Deasy,
Allen Tannenbaum,
Wei Lu
Abstract:
Spiculations are important predictors of lung cancer malignancy, which are spikes on the surface of the pulmonary nodules. In this study, we proposed an interpretable and parameter-free technique to quantify the spiculation using area distortion metric obtained by the conformal (angle-preserving) spherical parameterization. We exploit the insight that for an angle-preserved spherical mapping of a…
▽ More
Spiculations are important predictors of lung cancer malignancy, which are spikes on the surface of the pulmonary nodules. In this study, we proposed an interpretable and parameter-free technique to quantify the spiculation using area distortion metric obtained by the conformal (angle-preserving) spherical parameterization. We exploit the insight that for an angle-preserved spherical mapping of a given nodule, the corresponding negative area distortion precisely characterizes the spiculations on that nodule. We introduced novel spiculation scores based on the area distortion metric and spiculation measures. We also semi-automatically segment lung nodule (for reproducibility) as well as vessel and wall attachment to differentiate the real spiculations from lobulation and attachment. A simple pathological malignancy prediction model is also introduced. We used the publicly-available LIDC-IDRI dataset pathologists (strong-label) and radiologists (weak-label) ratings to train and test radiomics models containing this feature, and then externally validate the models. We achieved AUC$=$0.80 and 0.76, respectively, with the models trained on the 811 weakly-labeled LIDC datasets and tested on the 72 strongly-labeled LIDC and 73 LUNGx datasets; the previous best model for LUNGx had AUC$=$0.68. The number-of-spiculations feature was found to be highly correlated (Spearman's rank correlation coefficient $ρ= 0.44$) with the radiologists' spiculation score. We developed a reproducible and interpretable, parameter-free technique for quantifying spiculations on nodules. The spiculation quantification measures was then applied to the radiomics framework for pathological malignancy prediction with reproducible semi-automatic segmentation of nodule. Using our interpretable features (size, attachment, spiculation, lobulation), we were able to achieve higher performance than previous models.
△ Less
Submitted 15 October, 2020; v1 submitted 24 August, 2018;
originally announced August 2018.