Skip to main content

Showing 1–24 of 24 results for author: Razansky, D

  1. arXiv:2403.07116  [pdf, other

    eess.IV cs.CV

    Simulation-Based Segmentation of Blood Vessels in Cerebral 3D OCTA Images

    Authors: Bastian Wittmann, Lukas Glandorf, Johannes C. Paetzold, Tamaz Amiranashvili, Thomas Wälchli, Daniel Razansky, Bjoern Menze

    Abstract: Segmentation of blood vessels in murine cerebral 3D OCTA images is foundational for in vivo quantitative analysis of the effects of neurovascular disorders, such as stroke or Alzheimer's, on the vascular network. However, to accurately segment blood vessels with state-of-the-art deep learning methods, a vast amount of voxel-level annotations is required. Since cerebral 3D OCTA images are typically… ▽ More

    Submitted 11 March, 2024; originally announced March 2024.

  2. arXiv:2402.06749  [pdf

    physics.optics physics.bio-ph physics.med-ph

    Copper phosphate micro-flowers coated with indocyanine green and iron oxide nanoparticles for in vivo localization optoacoustic tomography and magnetic actuation

    Authors: Daniil Nozdriukhin, Shuxin Lyu, Jerome Bonvin, Michael Reiss, Daniel Razansky, Xose Luis Dean-Ben

    Abstract: Efficient drug delivery is a major challenge in modern medicine and pharmaceutical research. Micrometer-scale robots have recently been proposed as a promising venue to amplify precision of drug administration. Remotely controlled microrobots sufficiently small to navigate through microvascular networks can reach any part of the human body, yet real-time tracking is crucial for providing precise g… ▽ More

    Submitted 9 February, 2024; originally announced February 2024.

  3. arXiv:2309.12838  [pdf

    physics.med-ph

    Influence of shear waves on transcranial ultrasound propagation in cortical brain regions

    Authors: Ya Gao, Beat Werner, Beatrice Lauber, Yiming Chen, Giovanni Colacicco, Daniel Razansky, Héctor Estrada

    Abstract: Transcranial ultrasound applications require accurate simulations to predict intracranial acoustic pressure fields. The current gold standard typically consists of calculating a longitudinal ultrasound wave propagation using a fluid skull model, which is based on full head CT images for retrieving the skull's geometry and elastic constants. Although this approach has extensively been validated for… ▽ More

    Submitted 22 September, 2023; originally announced September 2023.

  4. arXiv:2304.04305  [pdf

    physics.optics physics.med-ph

    Multi-scale volumetric dynamic optoacoustic and laser ultrasound (OPLUS) imaging enabled by semi-transparent optical guidance

    Authors: Daniil Nozdriukhin, Sandeep Kumar Kalva, Cagla Özsoy, Michael Reiss, Weiye Li, Daniel Razansky, Xosé Luís Deán-Ben

    Abstract: Major biological discoveries have been made by interrogating living organisms with light. However, the limited penetration of unscattered photons within biological tissues severely limits the depth range covered by optical methods. Deep-tissue imaging has been achieved by combining light and ultrasound. Optoacoustic imaging uniquely exploits optical generation of ultrasound to render high-resoluti… ▽ More

    Submitted 9 April, 2023; originally announced April 2023.

    Comments: 21 pages, 4 figures

  5. arXiv:2206.08612  [pdf, other

    eess.IV cs.CV

    OADAT: Experimental and Synthetic Clinical Optoacoustic Data for Standardized Image Processing

    Authors: Firat Ozdemir, Berkan Lafci, Xosé Luís Deán-Ben, Daniel Razansky, Fernando Perez-Cruz

    Abstract: Optoacoustic (OA) imaging is based on excitation of biological tissues with nanosecond-duration laser pulses followed by subsequent detection of ultrasound waves generated via light-absorption-mediated thermoelastic expansion. OA imaging features a powerful combination between rich optical contrast and high resolution in deep tissues. This enabled the exploration of a number of attractive new appl… ▽ More

    Submitted 3 May, 2023; v1 submitted 17 June, 2022; originally announced June 2022.

    Comments: Accepted to TMLR. 32 pages, 24 figures, 9 tables

    Journal ref: Transactions on Machine Learning Research (2023) 2835-8856

  6. arXiv:2109.01880  [pdf, other

    eess.IV cs.CV cs.LG

    Deep learning facilitates fully automated brain image registration of optoacoustic tomography and magnetic resonance imaging

    Authors: Yexing Hu, Berkan Lafci, Artur Luzgin, Hao Wang, Jan Klohs, Xose Luis Dean-Ben, Ruiqing Ni, Daniel Razansky, Wuwei Ren

    Abstract: Multi-spectral optoacoustic tomography (MSOT) is an emerging optical imaging method providing multiplex molecular and functional information from the rodent brain. It can be greatly augmented by magnetic resonance imaging (MRI) that offers excellent soft-tissue contrast and high-resolution brain anatomy. Nevertheless, registration of multi-modal images remains challenging, chiefly due to the entir… ▽ More

    Submitted 4 September, 2021; originally announced September 2021.

    Comments: 15 pages, 5 figures

  7. arXiv:2108.03958  [pdf, ps, other

    physics.med-ph physics.bio-ph physics.optics

    High resolution transcranial imaging based on the optoacoustic memory effect

    Authors: Xose Luis Dean-Ben, Daniel Razansky

    Abstract: Acoustic impedance mismatches between soft tissues and bones are known to result in strong aberrations in optoacoustic and ultrasound images. Of particular importance are the severe distortions introduced by the human skull, impeding transcranial brain imaging with these modalities. While modelling of ultrasound propagation through the skull may in principle help correcting for some of the skull-i… ▽ More

    Submitted 9 August, 2021; originally announced August 2021.

  8. arXiv:2106.08722  [pdf, other

    physics.app-ph physics.ins-det physics.med-ph

    High order pulse-echo (HOPE) ultrasound

    Authors: Urs A. T. Hofmann, Sergio Pérez-López, Héctor Estrada, Daniel Razansky

    Abstract: Multiple reflections between transducer and imaged object can naturally occur in ultrasound imaging and other acoustic sensing applications such as sonar. The repeated interaction of the emitted wavefront with the imaged object is traditionally regarded an undesired reverberation artifact, often misinterpreted as fictitious acoustic boundaries. Here we introduce high order reflection pulse-echo (H… ▽ More

    Submitted 16 June, 2021; originally announced June 2021.

    Comments: 18 pages, 5 figures

  9. arXiv:2101.00622  [pdf

    physics.med-ph

    Dual-Mode Volumetric Optoacoustic and Contrast Enhanced Ultrasound Imaging with Spherical Matrix Arrays

    Authors: Justine Robin, Ali Ozbek, Michael Reiss, Xose-Luis Dean-Ben, Daniel Razansky

    Abstract: Spherical matrix arrays arguably represent an advantageous tomographic detection geometry for non-invasive deep tissue mapping of vascular networks and oxygenation with volumetric optoacoustic tomography (VOT). Hybridization of VOT with ultrasound (US) imaging remains difficult with this configuration due to the relatively large inter-element pitch of spherical arrays. We suggest a new approach fo… ▽ More

    Submitted 3 January, 2021; originally announced January 2021.

  10. arXiv:2009.10173  [pdf

    physics.med-ph physics.bio-ph physics.ins-det physics.optics

    Broadband model-based inversion enables optoacoustic microscopy beyond the acoustic diffraction limit

    Authors: Weiye Li, Urs A. T. Hofmann, Johannes Rebling, Ali Ozbek, Yuxiang Gong, Daniel Razansky, Xose Luis Dean-Ben

    Abstract: Acoustic-resolution optoacoustic microscopy (AR-OAM) retrieves anatomical and functional contrast from living tissues at depths not reachable with optical microscopy. The imaging performance of AR-OAM has been advanced with image reconstruction algorithms providing high lateral resolution ultimately limited by acoustic diffraction. In this work, we suggest a new model-based framework efficiently e… ▽ More

    Submitted 21 October, 2020; v1 submitted 21 September, 2020; originally announced September 2020.

  11. arXiv:2007.00372  [pdf

    physics.bio-ph physics.optics

    Noninvasive three-dimensional optoacoustic localization microangiography of deep tissues

    Authors: Xosé Luís Deán-Ben, Justine Robin, Ruiqing Ni, Daniel Razansky

    Abstract: Structural microvascular alterations and dysfunction serve as key disease indicators of cancer, diabetes, ischemic stroke, neurodegenerative disorders and many other conditions. In vivo visualization of the microvasculature has traditionally been restricted to millimeter scale depths accessible with optical microscopy. Optoacoustic imaging has enabled breaking through the barrier imposed by light… ▽ More

    Submitted 1 July, 2020; originally announced July 2020.

  12. arXiv:1902.05948  [pdf

    physics.bio-ph eess.IV

    Acoustic scattering mediated single detector optoacoustic tomography

    Authors: Xose Luis Dean-Ben, Ali Ozbek, Hernan Lopez-Schier, Daniel Razansky

    Abstract: Optoacoustic image formation is conventionally based upon ultrasound time-of-flight readings from multiple detection positions. Herein, we exploit acoustic scattering to physically encode the position of optical absorbers in the acquired signals, thus reduce the amount of data required to reconstruct an image from a single waveform. This concept is experimentally tested by including a random distr… ▽ More

    Submitted 14 February, 2019; originally announced February 2019.

    Comments: 4 pages, 3 figures

    Journal ref: Phys. Rev. Lett. 123, 174301 (2019)

  13. Sub-micron silicon-on-insulator resonator for ultrasound detection

    Authors: Rami Shnaiderman, Georg Wissmeyer, Héctor Estrada, Daniel Razansky, Qutaiba Mustafa, Andriy Chmyrov, Vasilis Ntziachristos

    Abstract: Point-like broadband ultrasound detection can significantly increase the resolution of ultrasonography and optoacoustic (photoacoustic) imaging, yet current ultrasound detectors cannot be miniaturised sufficiently. Piezoelectric transducers lose sensitivity quadratically with size reduction, while optical micro-ring resonators and Fabry-Pérot etalons fail to adequately confine light at dimensions… ▽ More

    Submitted 11 February, 2019; originally announced February 2019.

  14. arXiv:1802.00876  [pdf, other

    physics.med-ph cond-mat.mtrl-sci

    Observation of guided acoustic waves in a human skull

    Authors: Hector Estrada, Sven Gottschalk, Michael Reiss, Volker Neuschmelting, Roland Goldbrunner, Daniel Razansky

    Abstract: Human skull poses a significant barrier for the propagation of ultrasound waves. Development of methods enabling more efficient ultrasound transmission into and from the brain is therefore critical for the advancement of ultrasound-mediated transcranial imaging or actuation techniques. We report on the first observation of guided acoustic waves in the near-field of an ex vivo human skull specimen… ▽ More

    Submitted 3 June, 2018; v1 submitted 2 February, 2018; originally announced February 2018.

    Comments: 4 pages, 3 figures, 1 table

  15. arXiv:1707.08391  [pdf, other

    physics.med-ph cs.CV eess.IV physics.optics

    Maximum entropy based non-negative optoacoustic tomographic image reconstruction

    Authors: Jaya Prakash, Subhamoy Mandal, Daniel Razansky, Vasilis Ntziachristos

    Abstract: Objective:Optoacoustic (photoacoustic) tomography is aimed at reconstructing maps of the initial pressure rise induced by the absorption of light pulses in tissue. In practice, due to inaccurate assumptions in the forward model, noise and other experimental factors, the images are often afflicted by artifacts, occasionally manifested as negative values. The aim of the work is to develop an inversi… ▽ More

    Submitted 11 January, 2019; v1 submitted 26 July, 2017; originally announced July 2017.

    Comments: This article has been accepted for publication in IEEE Transactions on Biomedical Engineering (30 Dec 2018)

  16. arXiv:1707.02145  [pdf, ps, other

    physics.optics physics.bio-ph

    Localization optoacoustic tomography

    Authors: Xose Luis Dean-Ben, Daniel Razansky

    Abstract: Localization-based imaging has revolutionized fluorescence optical microscopy and has also enabled unprecedented ultrasound images of microvascular structures in deep tissues. Herein, we introduce a new concept of localization optoacoustic tomography (LOAT) that employs rapid sequential acquisition of three-dimensional optoacoustic images from flowing absorbing particles. We show that the new meth… ▽ More

    Submitted 7 July, 2017; originally announced July 2017.

  17. arXiv:1606.05462  [pdf, other

    physics.med-ph cond-mat.other

    Prediction and near-field observation of skull-guided acoustic waves

    Authors: Héctor Estrada, Johannes Rebling, Daniel Razansky

    Abstract: Ultrasound waves propagating in water or soft biological tissue are strongly reflected when encountering the skull, which limits the use of ultrasound-based techniques in transcranial imaging and therapeutic applications. Current knowledge on the acoustic properties of the cranial bone is restricted to far-field observations, leaving its near-field properties unexplored. We report on the existence… ▽ More

    Submitted 15 September, 2016; v1 submitted 17 June, 2016; originally announced June 2016.

    Comments: 7 pages, 5 figures, appendix with 2 figures

  18. arXiv:1512.03289  [pdf, ps, other

    physics.optics physics.bio-ph physics.med-ph

    Dynamic particle enhancement in limited-view optoacoustic tomography

    Authors: X L Dean-Ben, L Ding, D Razansky

    Abstract: Limited-view artefacts are commonly present in optoacoustic tomography images, mainly due to practical geometrical and physical constraints imposed by the imaging systems as well as limited light penetration into large optically opaque samples. Herein, a new approach termed dynamic particle-enhanced optoacoustic tomography (DPOT) is proposed for improving image contrast and visibility of optoacous… ▽ More

    Submitted 10 December, 2015; originally announced December 2015.

  19. arXiv:1510.08174  [pdf

    physics.med-ph cs.CV eess.IV physics.optics

    Visual Quality Enhancement in Optoacoustic Tomography using Active Contour Segmentation Priors

    Authors: Subhamoy Mandal, Xosé Luís Deán-Ben, Daniel Razansky

    Abstract: Segmentation of biomedical images is essential for studying and characterizing anatomical structures, detection and evaluation of pathological tissues. Segmentation has been further shown to enhance the reconstruction performance in many tomographic imaging modalities by accounting for heterogeneities of the excitation field and tissue properties in the imaged region. This is particularly relevant… ▽ More

    Submitted 10 April, 2016; v1 submitted 27 October, 2015; originally announced October 2015.

    Comments: Accepted for publication in IEEE Transactions on Medical Imaging

    Journal ref: IEEE Transactions on Medical Imaging, vol. 35, no. 10, pp. 2209-2217, Oct. 2016

  20. arXiv:1506.03617  [pdf, ps, other

    physics.optics

    Influence of the absorber dimensions on wavefront shaping based on volumetric optoacoustic feedback

    Authors: X. L. Dean-Ben, H. Estrada, A. Ozbek, D. Razansky

    Abstract: The recently demonstrated control over light distribution through turbid media based on real-time three-dimensional optoacoustic feedback has offered promising prospects to interferometrically focus light within scattering objects. Nevertheless, the focusing capacity of the feedback-based approach is strongly conditioned by the number of effectively resolvable optical modes (speckles). In this let… ▽ More

    Submitted 11 June, 2015; originally announced June 2015.

  21. arXiv:1506.03124  [pdf, ps, other

    physics.med-ph cs.CV eess.IV

    Multiscale edge detection and parametric shape modeling for boundary delineation in optoacoustic images

    Authors: Subhamoy Mandal, Viswanath Pamulakanty Sudarshan, Yeshaswini Nagaraj, Xose Luis Dean Ben, Daniel Razansky

    Abstract: In this article, we present a novel scheme for segmenting the image boundary (with the background) in optoacoustic small animal in vivo imaging systems. The method utilizes a multiscale edge detection algorithm to generate a binary edge map. A scale dependent morphological operation is employed to clean spurious edges. Thereafter, an ellipse is fitted to the edge map through constrained parametric… ▽ More

    Submitted 9 June, 2015; originally announced June 2015.

    Comments: Engineering in Medicine and Biology Society (EMBC), 2015 37th Annual International Conference of the IEEE (Accepted version)

    Journal ref: Engineering in Medicine and Biology Society (EMBC), 2015 37th Annual International Conference of the IEEE , vol., no., pp.707-710, 25-29 Aug. 2015

  22. arXiv:1501.02450  [pdf

    q-bio.NC physics.med-ph physics.optics

    Functional optoacoustic neuro-tomography (FONT) for whole-brain monitoring of calcium indicators

    Authors: Gali Sela, Antonella Lauri, X. Luís Deán-Ben, Moritz Kneipp, Vasilis Ntziachristos, Shy Shoham, Gil G. Westmeyer, Daniel Razansky

    Abstract: Non-invasive observation of spatiotemporal neural activity of large neural populations distributed over entire brains is a longstanding goal of neuroscience. We developed a real-time volumetric and multispectral optoacoustic tomography platform for imaging of neural activation deep in scattering brains. The system can record 100 volumetric frames per second across a 200mm3 field of view and spatia… ▽ More

    Submitted 11 January, 2015; originally announced January 2015.

    Comments: 4 pages, 4 figures

  23. arXiv:1412.3241  [pdf

    physics.optics

    High contrast imaging of reversibly switchable fluorescent proteins via temporally unmixed Multispectral Optoacoustic Tomography (tuMSOT)

    Authors: Andre C Stiel, X Luis Dean-Ben, Yuanyuan Jiang, Vasilis Ntziachristos, Daniel Razansky, Gil G Westmeyer

    Abstract: Photocontrol of reversibly switchable fluorescent proteins (RSFPs) was used to program optoacoustic signal time courses that were temporally unmixed to increase the proteins contrast-to-noise-ratios (CNRs) in optoacoustic imaging. In this way, two variants of the RSFP Dronpa with very similar optoacoustic spectra could be readily discriminated in the presence of highly absorbing blood. Addition of… ▽ More

    Submitted 10 December, 2014; originally announced December 2014.

  24. arXiv:1409.7931  [pdf, other

    physics.optics

    Simultaneous control of volumetric light distribution through turbid media using real-time three-dimensional optoacoustic feedback

    Authors: X. Luís Deán-Ben, Héctor Estrada, Daniel Razansky

    Abstract: Focusing light through turbid media presents a highly fascinating challenge in modern biophotonics. The unique capability of optoacoustics for high resolution imaging of light absorption contrast in deep tissues can provide a natural and efficient feedback to control light delivery in scattering medium. While basic feasibility of using optoacoustic readings as a feedback mechanism for wavefront sh… ▽ More

    Submitted 2 February, 2015; v1 submitted 28 September, 2014; originally announced September 2014.

    Comments: 4 pages, 3 figures

    Journal ref: Optics Letters, Vol. 40, Issue 4, pp. 443-446 (2015)