-
Development towards high-resolution kHz-speed rotation-free volumetric imaging
Authors:
Eleni Myrto Asimakopoulou,
Valerio Bellucci,
Sarlota Birnsteinova,
Zisheng Yao,
Yuhe Zhang,
Ilia Petrov,
Carsten Deiter,
Andrea Mazzolari,
Marco Romagnoni,
Dusan Korytar,
Zdenko Zaprazny,
Zuzana Kuglerova,
Libor Juha,
Bratislav Lukic,
Alexander Rack,
Liubov Samoylova,
Francisco Garcia Moreno,
Stephen A Hall,
Tillmann Neu,
Xiaoyu Liang,
Patrik Vagovic,
Pablo Villanueva-Perez
Abstract:
X-ray multi-projection imaging (XMPI) provides rotation-free 3D movies of optically opaque samples. The absence of rotation enables superior imaging speed and preserves fragile sample dynamics by avoiding the shear forces introduced by conventional rotary tomography. Here, we present our XMPI observations at the ID19 beamline (ESRF, France) of 3D dynamics in melted aluminum with 1000 frames per se…
▽ More
X-ray multi-projection imaging (XMPI) provides rotation-free 3D movies of optically opaque samples. The absence of rotation enables superior imaging speed and preserves fragile sample dynamics by avoiding the shear forces introduced by conventional rotary tomography. Here, we present our XMPI observations at the ID19 beamline (ESRF, France) of 3D dynamics in melted aluminum with 1000 frames per second and 8 $μ$m resolution per projection using the full dynamical range of our detectors. Since XMPI is a method under development, we also provide different tests for the instrumentation of up to 3000 frames per second. As the flux of X-ray sources grows globally, XMPI is a promising technique for current and future X-ray imaging instruments.
△ Less
Submitted 7 November, 2023;
originally announced November 2023.
-
Ultrafast Radiographic Imaging and Tracking: An overview of instruments, methods, data, and applications
Authors:
Zhehui Wang,
Andrew F. T. Leong,
Angelo Dragone,
Arianna E. Gleason,
Rafael Ballabriga,
Christopher Campbell,
Michael Campbell,
Samuel J. Clark,
Cinzia Da Vià,
Dana M. Dattelbaum,
Marcel Demarteau,
Lorenzo Fabris,
Kamel Fezzaa,
Eric R. Fossum,
Sol M. Gruner,
Todd Hufnagel,
Xiaolu Ju,
Ke Li,
Xavier Llopart,
Bratislav Lukić,
Alexander Rack,
Joseph Strehlow,
Audrey C. Therrien,
Julia Thom-Levy,
Feixiang Wang
, et al. (3 additional authors not shown)
Abstract:
Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art ionizing particle and light sources to experimentally study sub-nanosecond dynamic processes in physics, chemistry, biology, geology, materials science and other fields. These processes, fundamental to nuclear fusion energy, advanced manufacturing, green transportation and others, often involve one mole or more atoms, and t…
▽ More
Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art ionizing particle and light sources to experimentally study sub-nanosecond dynamic processes in physics, chemistry, biology, geology, materials science and other fields. These processes, fundamental to nuclear fusion energy, advanced manufacturing, green transportation and others, often involve one mole or more atoms, and thus are challenging to compute by using the first principles of quantum physics or other forward models. One of the central problems in U-RadIT is to optimize information yield through, e.g. high-luminosity X-ray and particle sources, efficient imaging and tracking detectors, novel methods to collect data, and large-bandwidth online and offline data processing, regulated by the underlying physics, statistics, and computing power. We review and highlight recent progress in: a.) Detectors; b.) U-RadIT modalities; c.) Data and algorithms; and d.) Applications. Hardware-centric approaches to U-RadIT optimization are constrained by detector material properties, low signal-to-noise ratio, high cost and long development cycles of critical hardware components such as ASICs. Interpretation of experimental data, including comparisons with forward models, is frequently hindered by sparse measurements, model and measurement uncertainties, and noise. Alternatively, U-RadIT make increasing use of data science and machine learning algorithms, including experimental implementations of compressed sensing. Machine learning and artificial intelligence approaches, refined by physics and materials information, may also contribute significantly to data interpretation, uncertainty quantification, and U-RadIT optimization.
△ Less
Submitted 4 September, 2023; v1 submitted 21 August, 2023;
originally announced August 2023.
-
Synchrotron-based X-ray Fluorescence Ghost Imaging
Authors:
Mathieu Manni,
Adi Ben-Yehuda,
Yishay Klein,
Bratislav Lukic,
Andrew Kingston,
Alexander Rack,
Sharon Shwartz,
Nicola Viganò
Abstract:
X-ray Fluorescence Ghost Imaging (XRF-GI) was recently demonstrated for x-ray lab sources. It has the potential to reduce acquisition time and deposited dose by choosing their trade-off with spatial resolution, while alleviating the focusing constraints of the probing beam. Here, we demonstrate the realization of synchrotron-based XRF-GI: We present both an adapted experimental setup and its corre…
▽ More
X-ray Fluorescence Ghost Imaging (XRF-GI) was recently demonstrated for x-ray lab sources. It has the potential to reduce acquisition time and deposited dose by choosing their trade-off with spatial resolution, while alleviating the focusing constraints of the probing beam. Here, we demonstrate the realization of synchrotron-based XRF-GI: We present both an adapted experimental setup and its corresponding required computational technique to process the data. This extends the above-mentioned potential advantages of GI to synchrotron XRF imaging. In addition, it enables new strategies to improve resilience against drifts at all scales, and the study of previously inaccessible samples, such as liquids.
△ Less
Submitted 18 August, 2023; v1 submitted 28 June, 2023;
originally announced June 2023.
-
Brittle fracture studied by ultra-high speed synchrotron X-ray diffraction imaging
Authors:
Antoine Petit,
Sylvia Pokam,
Frederic Mazen,
Samuel Tardif,
Didier Landru,
Oleg Kononchuk,
Nadia Ben Mohamed,
Margie P. Olbinado,
Alexander Rack,
Francois Rieutord
Abstract:
Ever since the very first human-made knapped tools, the control of fracture propagation in brittle materials has been a vector of technological development. Nowadays, a broad range of applications relies on crack propagation control, from the mitigation of damages, e.g., from impacts in glass screens or windshields, to industrial processes harnessing fracture to achieve clean cuts over large dista…
▽ More
Ever since the very first human-made knapped tools, the control of fracture propagation in brittle materials has been a vector of technological development. Nowadays, a broad range of applications relies on crack propagation control, from the mitigation of damages, e.g., from impacts in glass screens or windshields, to industrial processes harnessing fracture to achieve clean cuts over large distances. Yet, studying the fracture in real time is a challenging task, since cracks can propagate up to a few km/s in materials that are often opaque. Here, we report on the in situ investigation of cracks propagating at up to 2.5 km/s along a (001) plane of a silicon single crystal, using X-ray diffraction megahertz imaging with intense and time-structured synchrotron radiation. The studied system is based on the Smart Cut process, where a buried layer in a material (typically Si) is weakened by micro-cracks and then used to drive a macroscopic crack (0.1 m) in a plane parallel to the surface with minimal deviation (1 nm). The results we report here provide the first direct confirmation that the shape of the crack front is not affected by the distribution of the micro-cracks, which had been a postulate for previous studies based on post-fracture results. We further measured instantaneous crack velocities over the centimeter-wide field-of-view, which had only been previously inferred from sparse point measurements, and evidence the effect of local heating by the X-ray beam. Finally, we also observed the post-crack movements of the separated wafer parts, which can be explained using pneumatics and elasticity. Thus, this study provides a comprehensive view of controlled fracture propagation in a crystalline material, paving the way for the in situ measurement of ultra-fast strain field propagation.
△ Less
Submitted 12 April, 2022;
originally announced April 2022.
-
Ghost projection. II. Beam shaping using realistic spatially-random masks
Authors:
David Ceddia,
Andrew M. Kingston,
Daniele Pelliccia,
Alexander Rack,
David M. Paganin
Abstract:
Spatial light modulation is important for many scientific and industrial applications. The spatial light modulator and optical data projector both rely on precisely configurable optical elements to shape a light beam. Here we explore an image-projection approach which does not require a configurable beam-shaping element. We term this approach ghost projection on account of its conceptual relation…
▽ More
Spatial light modulation is important for many scientific and industrial applications. The spatial light modulator and optical data projector both rely on precisely configurable optical elements to shape a light beam. Here we explore an image-projection approach which does not require a configurable beam-shaping element. We term this approach ghost projection on account of its conceptual relation to computational ghost imaging. Instead of a configurable beam shaping element, the method transversely displaces a single illuminated mask, such as a spatially-random screen, to create specified distributions of radiant exposure. The method has potential applicability to image projection employing a variety of radiation and matter wave fields, such as hard x rays, neutrons, muons, atomic beams and molecular beams. Building on our previous theoretical and computational studies, we here seek to understand the effects, sensitivity, and tolerance of some key experimental limitations of the method. Focusing on the case of hard x rays, we employ experimentally acquired masks to numerically study the deleterious effects of photon shot noise, inaccuracies in random-mask exposure time, and inaccuracies in mask positioning, as well as adapting to spatially non-uniform illumination. Understanding the influence of these factors will assist in optimizing experimental design and work towards achieving ghost projection in practice.
△ Less
Submitted 14 August, 2022; v1 submitted 18 February, 2022;
originally announced February 2022.
-
Boosting spatial resolution by incorporating periodic boundary conditions into single-distance hard-x-ray phase retrieval
Authors:
David M. Paganin,
Vincent Favre-Nicolin,
Alessandro Mirone,
Alexander Rack,
Julie Villanova,
Margie P. Olbinado,
Vincent Fernandez,
Julio C. da Silva,
Daniele Pelliccia
Abstract:
A simple coherent-imaging method due to Paganin et al. is widely employed for phase-amplitude reconstruction of samples using a single paraxial x-ray propagation-based phase-contrast image. The method assumes that the sample-to-detector distance is sufficiently small for the associated Fresnel number to be large compared to unity. The algorithm is particularly effective when employed in a tomograp…
▽ More
A simple coherent-imaging method due to Paganin et al. is widely employed for phase-amplitude reconstruction of samples using a single paraxial x-ray propagation-based phase-contrast image. The method assumes that the sample-to-detector distance is sufficiently small for the associated Fresnel number to be large compared to unity. The algorithm is particularly effective when employed in a tomographic setting, using a single propagation-based phase-contrast image for each projection. Here we develop a simple extension of the method, which improves the reconstructed contrast of very fine sample features. This provides first-principles motivation for boosting fine spatial detail associated with high Fourier frequencies, relative to the original method, and was inspired by several recent works employing empirically-obtained Fourier filters to a similar end.
△ Less
Submitted 29 August, 2020; v1 submitted 7 May, 2020;
originally announced May 2020.
-
3D characterization of the primary Al3Sc phases in an Al-Sc alloy using Synchrotron X-ray tomography and electron microscopy
Authors:
Yuliang Zhao,
Weiwen Zhang,
Billy Koe,
Wenjia Du,
Mengmeng Wang,
Weilin Wang,
Elodie Boller,
Alexander Rack,
Zhenzhong Sun,
Jiawei Mi
Abstract:
The three-dimensional structures of the primary Al3Sc particles in an Al-2Sc master alloy were studied by synchrotron X-ray microtomography, scanning and transmission electron microscopy. The Al3Sc phases were found to be a single cube and a cluster of cubes. The surface area, equivalent diameter of the Al3Sc cubes increased with the increasing of cube volume, but the specific surface area decreas…
▽ More
The three-dimensional structures of the primary Al3Sc particles in an Al-2Sc master alloy were studied by synchrotron X-ray microtomography, scanning and transmission electron microscopy. The Al3Sc phases were found to be a single cube and a cluster of cubes. The surface area, equivalent diameter of the Al3Sc cubes increased with the increasing of cube volume, but the specific surface area decreases. The primary Al3Sc cubes and Al-matrix have the same crystal orientation, indicating that the Al3Sc phases are the heterogeneous nucleation sites for Al. The experimental results show that α-Al2O3 are the possible nucleation sites for the Al3Sc cubes.
△ Less
Submitted 20 September, 2019;
originally announced September 2019.
-
Megahertz X-ray microscopy at X-ray Free-Electron Laser and Synchrotron sources
Authors:
Patrik Vagovič,
Tokushi Sato,
Ladislav Mikeš,
Grant Mills,
Rita Graceffa,
Frans Mattsson,
Pablo Villanueva-Perez,
Alexey Ershov,
Tomáš Faragó,
Jozef Uličný,
Henry Kirkwood,
Romain Letrun,
Rajmund Mokso,
Marie-Christine Zdora,
Margie P. Olbinado,
Alexander Rack,
Tilo Baumbach,
Alke Meents,
Henry N. Chapman,
Adrian P. Mancuso
Abstract:
We demonstrate X-ray phase contrast microscopy performed at the European X-ray Free-Electron Laser sampled at 1.128 MHz rate. We have applied this method to image stochastic processes induced by an optical laser incident on water-filled capillaries with micrometer scale spatial resolution. The generated high speed water jet, cavitation formation and annihilation in water and glass, as well as glas…
▽ More
We demonstrate X-ray phase contrast microscopy performed at the European X-ray Free-Electron Laser sampled at 1.128 MHz rate. We have applied this method to image stochastic processes induced by an optical laser incident on water-filled capillaries with micrometer scale spatial resolution. The generated high speed water jet, cavitation formation and annihilation in water and glass, as well as glass explosions are observed. The comparison between XFEL and previous synchrotron MHz microscopy shows the superior contrast and spatial resolution at the XFEL over the synchrotron. This work opens up new possibilities for the characterization of dynamic stochastic systems on nanosecond to microsecond time scales at megahertz rate with object velocities up to few kilometers per second using X-ray Free-Electron Laser sources.
△ Less
Submitted 13 June, 2019;
originally announced June 2019.
-
Phase-sensitive x-ray ghost imaging
Authors:
Margie P. Olbinado,
David M. Paganin,
Yin Cheng,
Alexander Rack
Abstract:
Imaging with hard x-rays is an invaluable tool in medicine, biology, materials science, and cultural heritage. Propagation-based x-ray phase-contrast imaging and tomography have been mostly used to resolve micrometer-scale structures inside weakly absorbing objects as well as inside dense specimens. Indirect x-ray detection has been the key technology to achieve up to sub-micrometer spatial resolu…
▽ More
Imaging with hard x-rays is an invaluable tool in medicine, biology, materials science, and cultural heritage. Propagation-based x-ray phase-contrast imaging and tomography have been mostly used to resolve micrometer-scale structures inside weakly absorbing objects as well as inside dense specimens. Indirect x-ray detection has been the key technology to achieve up to sub-micrometer spatial resolutions, albeit inefficiently and hence at the expense of increased radiation dose to the specimen. A promising approach to low-dose imaging and high spatial resolution even at high x-ray energies is ghost imaging, which could use single-pixel, yet efficient direct x-ray detectors made of high-density materials. However, phase contrast has not yet been realised with x-ray ghost imaging. We present an approach which exploits both the advantages of x-ray ghost imaging and the high sensitivity of phase-contrast imaging. In comparison with existing techniques, our method is efficient and achieves high-fidelity x-ray ghost images with phase contrast, accurate density resolution and dramatically higher spatial resolution. The method is scalable to practical tomography with large fields of view, micrometer spatial resolution, and with high-energy x-rays above 100 keV. It is also applicable to other phase-sensitive imaging techniques and with other probes such as neutrons, alpha rays, and muons, for which high spatial resolution detectors are limited or even not available.
△ Less
Submitted 20 March, 2019;
originally announced March 2019.
-
Ghost Tomography
Authors:
Andrew. M. Kingston,
Daniele Pelliccia,
Alexander Rack,
Margie P. Olbinado,
Yin Cheng,
Glenn R. Myers,
David M. Paganin
Abstract:
Ghost tomography using single-pixel detection extends the emerging field of ghost imaging to three dimensions, with the use of penetrating radiation. In this work, a series of spatially random x-ray intensity patterns is used to illuminate a specimen in various tomographic angular orientations with only the total transmitted intensity being recorded by a single-pixel camera (or bucket detector). T…
▽ More
Ghost tomography using single-pixel detection extends the emerging field of ghost imaging to three dimensions, with the use of penetrating radiation. In this work, a series of spatially random x-ray intensity patterns is used to illuminate a specimen in various tomographic angular orientations with only the total transmitted intensity being recorded by a single-pixel camera (or bucket detector). The set of zero-dimensional intensity readings, combined with knowledge of the corresponding two-dimensional illuminating patterns and specimen orientations, is sufficient for three-dimensional reconstruction of the specimen. The experimental demonstration of ghost tomography is presented here using synchrotron hard x-rays. This result expands the scope of ghost imaging to encompass volumetric imaging (i.e., tomography), of optically opaque objects using penetrating radiation. For hard x-rays, ghost tomography has the potential to decouple image quality from dose rate as well as image resolution from detector performance.
△ Less
Submitted 31 May, 2018;
originally announced June 2018.
-
Practical x-ray ghost imaging with synchrotron light
Authors:
Daniele Pelliccia,
Margie P. Olbinado,
Alexander Rack,
David M. Paganin
Abstract:
We present a practical experimental realization of transmission x-ray ghost imaging using synchrotron light. Hard x-rays from an undulator were split by a Si 200 crystal in Laue geometry to produce two copies of a speckled incident beam. Both speckle beams were simultaneously measured on a CCD camera. The sample was inserted in one of the two beams, and the corresponding image was integrated over…
▽ More
We present a practical experimental realization of transmission x-ray ghost imaging using synchrotron light. Hard x-rays from an undulator were split by a Si 200 crystal in Laue geometry to produce two copies of a speckled incident beam. Both speckle beams were simultaneously measured on a CCD camera. The sample was inserted in one of the two beams, and the corresponding image was integrated over the camera extent to synthesize a bucket signal. We show the successful x-ray ghost image reconstruction of two samples and discuss different reconstruction strategies. We also demonstrate a method for measuring the point spread function of a ghost imaging system, which can be used to quantify the resolution of the ghost imaging reconstructions and quantitatively compare different reconstruction approaches. Our experimental results are discussed in view of future practical applications of x-ray ghost imaging, including a means for parallel ghost imaging.
△ Less
Submitted 15 September, 2017;
originally announced October 2017.
-
Experimental x-ray ghost imaging
Authors:
Daniele Pelliccia,
Alexander Rack,
Mario Scheel,
Valentina Cantelli,
David M. Paganin
Abstract:
We report an experimental proof of principle for ghost imaging in the hard x-ray energy range. We used a synchrotron x-ray beam that was split using a thin crystal in Laue diffraction geometry. With an ultra-fast imaging camera, we were able to image x-rays generated by isolated electron bunches. At this time scale, the shot noise of the synchrotron emission process is measurable as speckles, lead…
▽ More
We report an experimental proof of principle for ghost imaging in the hard x-ray energy range. We used a synchrotron x-ray beam that was split using a thin crystal in Laue diffraction geometry. With an ultra-fast imaging camera, we were able to image x-rays generated by isolated electron bunches. At this time scale, the shot noise of the synchrotron emission process is measurable as speckles, leading to speckle correlation between the two beams. The integrated transmitted intensity from a sample located in the first beam was correlated with the spatially resolved intensity measured on the second, empty, beam to retrieve the shadow of the sample. The demonstration of ghost imaging with hard x-rays may open the way to protocols to reduce radiation damage in medical imaging and in non-destructive structural characterization using Free Electron Lasers.
△ Less
Submitted 5 July, 2016; v1 submitted 16 May, 2016;
originally announced May 2016.
-
Dynamical bistability in quantum dot structures: The role of Auger processes
Authors:
A. Rack,
R. Wetzler,
A. Wacker,
E. Schöll
Abstract:
Bistability in quantum dot structures is examined by a drift-diffusion model in combination with electron capture and emission processes. Our simulations provide a dynamic scenario with extremely long switching times of the order of months and the results are in good agreement with the experimental findings of Yusa and Sakaki [Appl. Phys. Lett. {\bf 70}, 345 (1997)]. The analysis of the data sup…
▽ More
Bistability in quantum dot structures is examined by a drift-diffusion model in combination with electron capture and emission processes. Our simulations provide a dynamic scenario with extremely long switching times of the order of months and the results are in good agreement with the experimental findings of Yusa and Sakaki [Appl. Phys. Lett. {\bf 70}, 345 (1997)]. The analysis of the data supports the importance of Auger capture processes for quantum dots.
△ Less
Submitted 10 September, 2002; v1 submitted 3 July, 2002;
originally announced July 2002.