-
XPOL-III: a New-Generation VLSI CMOS ASIC for High-Throughput X-ray Polarimetry
Authors:
M. Minuti,
L. Baldini,
R. Bellazzini,
A. Brez,
M. Ceccanti,
F. Krummenacher,
L. Latronico,
L. Lucchesi,
A. Manfreda,
L. Orsini,
M. Pinchera,
A. Profeti,
C. Sgr`o,
G. Spandre
Abstract:
While the successful launch and operation in space of the Gas Pixel Detectors onboard the PolarLight cubesat and the Imaging X-ray Polarimetry Explorer demonstrate the viability and the technical soundness of this class of detectors for astronomical X-ray polarimetry, it is clear that the current state of the art is not ready to meet the challenges of the next generation of experiments, such as th…
▽ More
While the successful launch and operation in space of the Gas Pixel Detectors onboard the PolarLight cubesat and the Imaging X-ray Polarimetry Explorer demonstrate the viability and the technical soundness of this class of detectors for astronomical X-ray polarimetry, it is clear that the current state of the art is not ready to meet the challenges of the next generation of experiments, such as the enhanced X-ray Timing and Polarimetry mission, designed to allow for a significantly larger data throughput.
In this paper we describe the design and test of a new custom, self-triggering readout ASIC, dubbed XPOL-III, specifically conceived to address and overcome these limitations. While building upon the overall architecture of the previous generations, the new chip improves over its predecessors in several, different key areas: the sensitivity of the trigger electronics, the flexibility in the definition of the readout window, as well as the maximum speed for the serial event readout. These design improvements, when combined, allow for almost an order of magnitude smaller dead time per event with no measurable degradation of the polarimetric, spectral, imaging or timing capability of the detector, providing a good match for the next generation of X-ray missions.
△ Less
Submitted 19 October, 2022; v1 submitted 30 August, 2022;
originally announced August 2022.
-
Calibration of the IXPE focal plane X-ray polarimeters to polarized radiation
Authors:
Alessandro Di Marco,
Sergio Fabiani,
Fabio La Monaca,
Fabio Muleri,
John Rankin,
Paolo Soffitta,
Fei Xie,
Fabrizio Amici,
Primo attinà,
Matteo Bachetti,
Luca Baldini,
Mattia Barbanera,
Wayne Baumgartner,
Ronaldo Bellazzini,
Fabio Borotto,
Alessandro Brez,
Daniele Brienza,
Ciro Caporale,
Claudia Cardelli,
Rita Carpentiero,
Simone Castellano,
Marco Castronuovo,
Luca Cavalli,
Elisabetta Cavazzuti,
Marco Ceccanti
, et al. (58 additional authors not shown)
Abstract:
IXPE (Imaging X-ray Polarimetry Explorer) is a NASA Small Explorer mission -- in partnership with the Italian Space Agency (ASI) -- dedicated to X-ray polarimetry in the 2--8 keV energy band. The IXPE telescope comprises three grazing incidence mirror modules coupled to three detector units hosting each one a Gas Pixel Detector (GPD), a gas detector that allows measuring the polarization degree by…
▽ More
IXPE (Imaging X-ray Polarimetry Explorer) is a NASA Small Explorer mission -- in partnership with the Italian Space Agency (ASI) -- dedicated to X-ray polarimetry in the 2--8 keV energy band. The IXPE telescope comprises three grazing incidence mirror modules coupled to three detector units hosting each one a Gas Pixel Detector (GPD), a gas detector that allows measuring the polarization degree by using the photoelectric effect. A wide and accurate ground calibration was carried out on the IXPE Detector Units (DUs) at INAF-IAPS, in Italy, where a dedicated facility was set-up at this aim. In this paper, we present the results obtained from this calibration campaign to study the IXPE focal plane detector response to polarized radiation. In particular, we report on the modulation factor, which is the main parameter to estimate the sensitivity of a polarimeter.
△ Less
Submitted 15 June, 2022;
originally announced June 2022.
-
The Imaging X-Ray Polarimetry Explorer (IXPE): Pre-Launch
Authors:
Martin C. Weisskopf,
Paolo Soffitta,
Luca Baldini,
Brian D. Ramsey,
Stephen L. O'Dell,
Roger W. Romani,
Giorgio Matt,
William D. Deininger,
Wayne H. Baumgartner,
Ronaldo Bellazzini,
Enrico Costa,
Jeffery J. Kolodziejczak,
Luca Latronico,
Herman L. Marshall,
Fabio Muleri,
Stephen D. Bongiorno,
Allyn Tennant,
Niccolo Bucciantini,
Michal Dovciak,
Frederic Marin,
Alan Marscher,
Juri Poutanen,
Pat Slane,
Roberto Turolla,
William Kalinowski
, et al. (133 additional authors not shown)
Abstract:
Scheduled to launch in late 2021, the Imaging X-ray Polarimetry Explorer (IXPE) is a NASA Small Explorer Mission in collaboration with the Italian Space Agency (ASI). The mission will open a new window of investigation - imaging X-ray polarimetry. The observatory features 3 identical telescopes each consisting of a mirror module assembly with a polarization-sensitive imaging X-ray detector at the…
▽ More
Scheduled to launch in late 2021, the Imaging X-ray Polarimetry Explorer (IXPE) is a NASA Small Explorer Mission in collaboration with the Italian Space Agency (ASI). The mission will open a new window of investigation - imaging X-ray polarimetry. The observatory features 3 identical telescopes each consisting of a mirror module assembly with a polarization-sensitive imaging X-ray detector at the focus. A coilable boom, deployed on orbit, provides the necessary 4-m focal length. The observatory utilizes a 3-axis-stabilized spacecraft which provides services such as power, attitude determination and control, commanding, and telemetry to the ground. During its 2-year baseline mission, IXPE will conduct precise polarimetry for samples of multiple categories of X-ray sources, with follow-on observations of selected targets.
△ Less
Submitted 21 December, 2021; v1 submitted 2 December, 2021;
originally announced December 2021.
-
The Instrument of the Imaging X-ray Polarimetry Explorer
Authors:
Paolo Soffitta,
Luca Baldini,
Ronaldo Bellazzini,
Enrico Costa,
Luca Latronico,
Fabio Muleri,
Ettore Del Monte,
Sergio Fabiani,
Massimo Minuti,
Michele Pinchera,
Carmelo Sgrò,
Gloria Spandre,
Alessio Trois,
Fabrizio Amici,
Hans Andersson,
Primo Attinà,
Matteo Bachetti,
Mattia Barbanera,
Fabio Borotto,
Alessandro Brez,
Daniele Brienza,
Ciro Caporale,
Claudia Cardelli,
Rita Carpentiero,
Simone Castellano
, et al. (56 additional authors not shown)
Abstract:
While X-ray Spectroscopy, Timing and Imaging have improved verymuch since 1962, when the first astronomical non-solar source was discovered, especially with the launch of Newton/X-ray Multi-Mirror Mission, Rossi/X-ray Timing Explorer and Chandra/Advanced X-ray Astrophysics Facility, the progress of X-ray polarimetry has been meager. This is in part due to the lack of sensitive polarization detecto…
▽ More
While X-ray Spectroscopy, Timing and Imaging have improved verymuch since 1962, when the first astronomical non-solar source was discovered, especially with the launch of Newton/X-ray Multi-Mirror Mission, Rossi/X-ray Timing Explorer and Chandra/Advanced X-ray Astrophysics Facility, the progress of X-ray polarimetry has been meager. This is in part due to the lack of sensitive polarization detectors, in part due to the fate of approved missions and in part because the celestial X-ray sources appeared less polarized than expected. Only one positive measurement has been available until now. Indeed the eight Orbiting Solar Observatory measured the polarization of the Crab nebula in the 70s.
The advent of techniques of microelectronics allowed for designing a detector based on the photoelectric effect in gas in an energy range where the optics are efficient in focusing X-rays. Herewe describe the Instrument, which is the major contribution of the Italian collaboration to the SmallExplorer mission called IXPE, the Imaging X-ray Polarimetry Explorer, which will be flown in late 2021. The instrument, is composed of three Detector Units, based on this technique, and a Detector Service Unit. Three Mirror Modules provided by Marshall Space Flight Center focus X-rays onto the detectors. In the following we will show the technological choices, their scientific motivation and the results from the calibration of the Instrument.
IXPE will perform imaging, timing and energy resolved polarimetry in the 2-8 keV energy band opening this window of X-ray astronomy to tens of celestial sources of almost all classes.
△ Less
Submitted 31 July, 2021;
originally announced August 2021.
-
Design, Construction, and Test of the Gas Pixel Detectors for the IXPE Mission
Authors:
L. Baldini,
M. Barbanera,
R. Bellazzini,
R. Bonino,
F. Borotto,
A. Brez,
C. Caporale,
C. Cardelli,
S. Castellano,
M. Ceccanti,
S. Citraro,
N. Di Lalla,
L. Latronico,
L. Lucchesi,
C. Magazzù,
G. Magazzù,
S. Maldera,
A. Manfreda,
M. Marengo,
A. Marrocchesi,
P. Mereu,
M. Minuti,
F. Mosti,
H. Nasimi,
A. Nuti
, et al. (69 additional authors not shown)
Abstract:
Due to be launched in late 2021, the Imaging X-Ray Polarimetry Explorer (IXPE) is a NASA Small Explorer mission designed to perform polarization measurements in the 2-8 keV band, complemented with imaging, spectroscopy and timing capabilities. At the heart of the focal plane is a set of three polarization-sensitive Gas Pixel Detectors (GPD), each based on a custom ASIC acting as a charge-collectin…
▽ More
Due to be launched in late 2021, the Imaging X-Ray Polarimetry Explorer (IXPE) is a NASA Small Explorer mission designed to perform polarization measurements in the 2-8 keV band, complemented with imaging, spectroscopy and timing capabilities. At the heart of the focal plane is a set of three polarization-sensitive Gas Pixel Detectors (GPD), each based on a custom ASIC acting as a charge-collecting anode. In this paper we shall review the design, manufacturing, and test of the IXPE focal-plane detectors, with particular emphasis on the connection between the science drivers, the performance metrics and the operational aspects. We shall present a thorough characterization of the GPDs in terms of effective noise, trigger efficiency, dead time, uniformity of response, and spectral and polarimetric performance. In addition, we shall discuss in detail a number of instrumental effects that are relevant for high-level science analysis -- particularly as far as the response to unpolarized radiation and the stability in time are concerned.
△ Less
Submitted 12 July, 2021;
originally announced July 2021.
-
Matching in a family of piecewise affine maps
Authors:
Henk Bruin,
Carlo Carminati,
Stefano Marmi,
Alessandro Profeti
Abstract:
We consider a class of simple one parameter families of interval maps, and we study how metric (resp. topological) entropy changes as the parameter varies. We show that in many cases the entropy displays a semi-regular behaviour, i.e. it is smooth on an open and dense set. This feature is due to a combinatorial property called matching
We consider a class of simple one parameter families of interval maps, and we study how metric (resp. topological) entropy changes as the parameter varies. We show that in many cases the entropy displays a semi-regular behaviour, i.e. it is smooth on an open and dense set. This feature is due to a combinatorial property called matching
△ Less
Submitted 24 July, 2017;
originally announced July 2017.
-
Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector
Authors:
M. Dragicevic,
M. Friedl,
J. Hrubec,
H. Steininger,
A. Gädda,
J. Härkönen,
T. Lampén,
P. Luukka,
T. Peltola,
E. Tuominen,
E. Tuovinen,
A. Winkler,
P. Eerola,
T. Tuuva,
G. Baulieu,
G. Boudoul,
L. Caponetto,
C. Combaret,
D. Contardo,
T. Dupasquier,
G. Gallbit,
N. Lumb,
L. Mirabito,
S. Perries,
M. Vander Donckt
, et al. (462 additional authors not shown)
Abstract:
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator…
▽ More
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is $99.95\pm0.05\,\%$, while the intrinsic spatial resolutions are $4.80\pm0.25\,μ\mathrm{m}$ and $7.99\pm0.21\,μ\mathrm{m}$ along the $100\,μ\mathrm{m}$ and $150\,μ\mathrm{m}$ pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.
△ Less
Submitted 1 June, 2017;
originally announced June 2017.
-
The entropy of alpha-continued fractions: numerical results
Authors:
Carlo Carminati,
Stefano Marmi,
Alessandro Profeti,
Giulio Tiozzo
Abstract:
We consider the one-parameter family of interval maps arising from generalized continued fraction expansions known as alpha-continued fractions. For such maps, we perform a numerical study of the behaviour of metric entropy as a function of the parameter. The behaviour of entropy is known to be quite regular for parameters for which a matching condition on the orbits of the endpoints holds. We g…
▽ More
We consider the one-parameter family of interval maps arising from generalized continued fraction expansions known as alpha-continued fractions. For such maps, we perform a numerical study of the behaviour of metric entropy as a function of the parameter. The behaviour of entropy is known to be quite regular for parameters for which a matching condition on the orbits of the endpoints holds. We give a detailed description of the set M where this condition is met: it consists of a countable union of open intervals, corresponding to different combinatorial data, which appear to be arranged in a hierarchical structure. Our experimental data suggest that the complement of M is a proper subset of the set of bounded-type numbers, hence it has measure zero. Furthermore, we give evidence that the entropy on matching intervals is smooth; on the other hand, we can construct points outside of M on which it is not even locally monotone.
△ Less
Submitted 11 December, 2009;
originally announced December 2009.