Skip to main content

Showing 1–50 of 54 results for author: Piegsa, F M

  1. arXiv:2410.07914  [pdf, other

    physics.ins-det nucl-ex

    Generating a highly uniform magnetic field inside the magnetically shielded room of the n2EDM experiment

    Authors: C. Abel, N. J. Ayres, G. Ban, G. Bison, K. Bodek, V. Bondar, T. Bouillaud, D. C. Bowles, G. L. Caratsch, E. Chanel, W. Chen, P. -J. Chiu, C. Crawford, B. Dechenaux, C. B. Doorenbos, S. Emmenegger, L. Ferraris-Bouchez, M. Fertl, P. Flaux, A. Fratangelo, D. Goupillière, W. C. Griffith, D. Höhl, M. Kasprzak, K. Kirch , et al. (41 additional authors not shown)

    Abstract: We present a coil system designed to generate a highly uniform magnetic field for the n2EDM experiment at the Paul Scherrer Institute. It consists of a main $B_0$ coil and a set of auxiliary coils mounted on a cubic structure with a side length of 273 cm, inside a large magnetically shielded room (MSR). We have assembled this system and characerized its performances with a mapping robot. The appar… ▽ More

    Submitted 10 October, 2024; originally announced October 2024.

    Comments: 20 pages, 13 figures

  2. arXiv:2406.15388  [pdf, other

    physics.ins-det

    Frequency-offset separated oscillatory fields technique applied to neutrons

    Authors: Anastasio Fratangelo, Philipp Heil, Christine Klauser, Gjon Markaj, Marc Persoz, Ciro Pistillo, Ivo Schulthess, Jacob Thorne, Florian M. Piegsa

    Abstract: The novel technique of frequency-offset separated oscillatory fields (FOSOF) has been originally proposed as a modification to Ramsey's method of separated oscillatory fields. It has recently been employed in precision measurements with atomic beams since it allows for an alternative approach to determine absolute resonance frequencies. We present results from a systematic investigation of the FOS… ▽ More

    Submitted 23 April, 2024; originally announced June 2024.

  3. arXiv:2402.15630  [pdf

    physics.ins-det nucl-ex

    In-beam test results of an RPC-based module for position-sensitive neutron detectors with timing readout

    Authors: G. Canezin, L. M. S. Margato, A. Morozov, A. Blanco, J. Saraiva, L. Lopes, P. Fonte, Chung Chuan Lai, Per-Olof Svensson, G. Markaj, Florian M. Piegsa

    Abstract: Recently we have proposed a new concept of a thermal neutron detector based on resistive plate chambers and 10B4C solid neutron converters, enabling to readout with high resolution in both the 3D position of neutron capture and the neutron time of flight (ToF). In this paper, we report the results of the first beam tests conducted with a new neutron RPC detection module, coupled to the position re… ▽ More

    Submitted 23 February, 2024; originally announced February 2024.

  4. arXiv:2309.16877  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Achieving ultra-low and -uniform residual magnetic fields in a very large magnetically shielded room for fundamental physics experiments

    Authors: N. J. Ayres, G. Ban, G. Bison, K. Bodek, V. Bondar, T. Bouillaud, D. Bowles, E. Chanel, W. Chen, P. -J. Chiu, C. B. Crawford, O. Naviliat-Cuncic, C. B. Doorenbos, S. Emmenegger, M. Fertl, A. Fratangelo, W. C. Griffith, Z. D. Grujic, P. G. Harris, K. Kirch, V. Kletzl, J. Krempel, B. Lauss, T. Lefort, A. Lejuez , et al. (25 additional authors not shown)

    Abstract: High-precision searches for an electric dipole moment of the neutron (nEDM) require stable and uniform magnetic field environments. We present the recent achievements of degaussing and equilibrating the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute. We present the final degaussing configuration that will be used for n2EDM after numerous studies. The optim… ▽ More

    Submitted 28 September, 2023; originally announced September 2023.

  5. arXiv:2307.07588  [pdf, other

    physics.ins-det hep-ex nucl-ex

    A large 'Active Magnetic Shield' for a high-precision experiment

    Authors: C. Abel, N. J. Ayres, G. Ban, G. Bison, K. Bodek, V. Bondar, T. Bouillaud, E. Chanel, J. Chen, W. Chen, P. -J. Chiu, C. B. Crawford, M. Daum, C. B. Doorenbos, S. Emmenegger, L. Ferraris-Bouchez, M. Fertl, A. Fratangelo, W. C. Griffith, Z. D. Grujic, P. Harris, K. Kirch, V. Kletzl, P. A. Koss, J. Krempel , et al. (26 additional authors not shown)

    Abstract: We present a novel Active Magnetic Shield (AMS), designed and implemented for the n2EDM experiment at the Paul Scherrer Institute. The experiment will perform a high-sensitivity search for the electric dipole moment of the neutron. Magnetic-field stability and control is of key importance for n2EDM. A large, cubic, 5m side length, magnetically shielded room (MSR) provides a passive, quasi-static s… ▽ More

    Submitted 14 July, 2023; originally announced July 2023.

  6. arXiv:2306.09663  [pdf, other

    hep-ex physics.ins-det

    Resonant Cancellation Effect in Ramsey Experiments

    Authors: Ivo Schulthess, Ivan Calic, Estelle Chanel, Anastasio Fratangelo, Philipp Heil, Christine Klauser, Gjon Markaj, Marc Persoz, Ciro Pistillo, Jacob Thorne, Florian M. Piegsa

    Abstract: We investigate the response of a Ramsey-type experiment on an additional oscillating magnetic field. This superimposed field is oriented in the same direction as the static main magnetic field and causes a modulation of the original Larmor spin precession frequency. The observable magnitude of this modulation reduces at higher frequencies of the oscillating field. It disappears completely if the i… ▽ More

    Submitted 16 June, 2023; originally announced June 2023.

  7. arXiv:2303.18108  [pdf, other

    physics.ins-det hep-ex

    A Ramsey apparatus for proton spins in flowing water

    Authors: Ivo Schulthess, Anastasio Fratangelo, Patrick Hautle, Philipp Heil, Gjon Markaj, Marc Persoz, Ciro Pistillo, Jacob Thorne, Florian M. Piegsa

    Abstract: We present an apparatus that applies Ramsey's method of separated oscillatory fields to proton spins in water molecules. The setup consists of a water circuit, a spin polarizer, a magnetically shielded interaction region with various radio frequency elements, and a nuclear magnetic resonance system to measure the spin polarization. We show that this apparatus can be used for Rabi resonance measure… ▽ More

    Submitted 19 June, 2023; v1 submitted 31 March, 2023; originally announced March 2023.

  8. Search for an interaction mediated by axion-like particles with ultracold neutrons at the PSI

    Authors: N. J. Ayres, G. Bison, K. Bodek, V. Bondar, T. Bouillaud, E. Chanel, P. -J. Chiu, B. Clement, C. B. Crawford, M. Daum, C. B. Doorenbos, S. Emmenegger, M. Fertl, P. Flaux, W. C. Griffith, P. G. Harris, N. Hild, M. Kasprzak, K. Kirch, V. Kletzl, P. A. Koss, J. Krempel, B. Lauss, T. Lefort, P. Mohanmurthy , et al. (22 additional authors not shown)

    Abstract: We report on a search for a new, short-range, spin-dependent interaction using a modified version of the experimental apparatus used to measure the permanent neutron electric dipole moment at the Paul Scherrer Institute. This interaction, which could be mediated by axion-like particles, concerned the unpolarized nucleons (protons and neutrons) near the material surfaces of the apparatus and polari… ▽ More

    Submitted 31 March, 2023; originally announced March 2023.

  9. arXiv:2212.02403  [pdf, other

    nucl-ex hep-ex hep-ph

    Search for ultralight axion dark matter in a side-band analysis of a 199Hg free-spin precession signal

    Authors: C. Abel, N. J. Ayres, G. Ban, G. Bison, K. Bodek, V. Bondar, E. Chanel, C. B. Crawford, M. Daum, B. Dechenaux, S. Emmenegger, P. Flaux, W. C. Griffith, P. G. Harris, Y. Kermaidic, K. Kirch, S. Komposch, P. A. Koss, J. Krempel, B. Lauss, T. Lefort, O. Naviliat-Cuncic, P. Mohanmurthy, D. Pais, F. M. Piegsa , et al. (13 additional authors not shown)

    Abstract: Ultra-low-mass axions are a viable dark matter candidate and may form a coherently oscillating classical field. Nuclear spins in experiments on Earth might couple to this oscillating axion dark-matter field, when propagating on Earth's trajectory through our Galaxy. This spin coupling resembles an oscillating pseudo-magnetic field which modulates the spin precession of nuclear spins. Here we repor… ▽ More

    Submitted 31 March, 2023; v1 submitted 2 December, 2022; originally announced December 2022.

    Comments: 18 pages, 4 images, submitted to SciPost Physics

    Journal ref: SciPost Phys. 15, 058 (2023)

  10. arXiv:2211.10396  [pdf, other

    physics.ins-det hep-ex hep-ph nucl-ex

    Particle Physics at the European Spallation Source

    Authors: H. Abele, A. Alekou, A. Algora, K. Andersen, S. Baessler, L. Barron-Palos, J. Barrow, E. Baussan, P. Bentley, Z. Berezhiani, Y. Bessler, A. K. Bhattacharyya, A. Bianchi, J. Bijnens, C. Blanco, N. Blaskovic Kraljevic, M. Blennow, K. Bodek, M. Bogomilov, C. Bohm, B. Bolling, E. Bouquerel, G. Brooijmans, L. J. Broussard, O. Buchan , et al. (154 additional authors not shown)

    Abstract: Presently under construction in Lund, Sweden, the European Spallation Source (ESS) will be the world's brightest neutron source. As such, it has the potential for a particle physics program with a unique reach and which is complementary to that available at other facilities. This paper describes proposed particle physics activities for the ESS. These encompass the exploitation of both the neutrons… ▽ More

    Submitted 30 January, 2024; v1 submitted 18 November, 2022; originally announced November 2022.

    Comments: 121 pages, updated version after referee comments

  11. arXiv:2206.10714  [pdf, other

    physics.ins-det hep-ex nucl-ex

    The `n2EDM MSR' -- a very large magnetically shielded room with an exceptional performance for fundamental physics measurements

    Authors: N. J. Ayres, G. Ban, G. Bison, K. Bodek, V. Bondar, T. Bouillaud, B. Clement, E. Chanel, P. -J. Chiu, C. B. Crawford, M. Daum, C. B. Doorenbos, S. Emmenegger, A. Fratangelo, M. Fertl, W. C. Griffith, Z. D. Grujic, P. G. Harris, K. Kirch, J. Krempel, B. Lauss, T. Lefort, O. Naviliat-Cuncic, D. Pais, F. M. Piegsa , et al. (19 additional authors not shown)

    Abstract: We present the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute which features an interior cubic volume with each side of length 2.92m, thus providing an accessible space of 25m3. The MSR has 87 openings up to 220mm diameter to operate the experimental apparatus inside, and an intermediate space between the layers for sensitive signal processing electronics.… ▽ More

    Submitted 21 June, 2022; originally announced June 2022.

    Comments: 10 pages, 15 Figures, submitted to Review of Scientific Instruments

  12. arXiv:2204.01454  [pdf, other

    hep-ex physics.ins-det

    New Limit on Axion-Like Dark Matter using Cold Neutrons

    Authors: Ivo Schulthess, Estelle Chanel, Anastasio Fratangelo, Alexander Gottstein, Andreas Gsponer, Zachary Hodge, Ciro Pistillo, Dieter Ries, Torsten Soldner, Jacob Thorne, Florian M. Piegsa

    Abstract: We report on a search for dark matter axion-like particles (ALPs) using a Ramsey-type apparatus for cold neutrons. A hypothetical ALP-gluon-coupling would manifest in a neutron electric dipole moment signal oscillating in time. Twenty-four hours of data have been analyzed in a frequency range from 23 $μ$Hz to 1 kHz, and no significant oscillating signal has been found. The usage of present dark-ma… ▽ More

    Submitted 16 July, 2022; v1 submitted 4 April, 2022; originally announced April 2022.

  13. arXiv:2103.09039  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Mapping of the magnetic field to correct systematic effects in a neutron electric dipole moment experiment

    Authors: C. Abel, N. J. Ayres, G. Ban, G. Bison, K. Bodek, V. Bondar, E. Chanel, P. -J. Chiu, B. Clément, C. B. Crawford, M. Daum, S. Emmenegger, L. Ferraris-Bouchez, M. Fertl, P. Flaux, A. Fratangelo, W. C. Griffith, Z. D. Grujić, P. G. Harris, L. Hayen, N. Hild, M. Kasprzak, K. Kirch, P. Knowles, H. -C. Koch , et al. (28 additional authors not shown)

    Abstract: Experiments dedicated to the measurement of the electric dipole moment of the neutron require outstanding control of the magnetic field uniformity. The neutron electric dipole moment (nEDM) experiment at the Paul Scherrer Institute uses a 199Hg co-magnetometer to precisely monitor magnetic field variations. This co-magnetometer, in the presence of field non-uniformity, is responsible for the large… ▽ More

    Submitted 3 May, 2022; v1 submitted 16 March, 2021; originally announced March 2021.

  14. arXiv:2102.01658  [pdf, other

    nucl-ex physics.atom-ph

    Johnson-Nyquist Noise Effects in Neutron Electric-Dipole-Moment Experiments

    Authors: N. J. Ayres, G. Ban, G. Bison, K. Bodek, V. Bondar, P. -J. Chiu, B. Clement, C. B. Crawford, M. Daum, S. Emmenegger, M. Fertl, A. Fratangelo, W. C. Griffith, Z. D. Grujić, P. G. Harris, K. Kirch, P. A. Koss, B. Lauss, T. Lefort, P. Mohanmurthy, O. Naviliat-Cuncic, D. Pais, F. M. Piegsa, G. Pignol, D. Rebreyend , et al. (15 additional authors not shown)

    Abstract: Magnetic Johnson-Nyquist noise (JNN) originating from metal electrodes, used to create a static electric field in neutron electric-dipole-moment (nEDM) experiments, may limit the sensitivity of measurements. We present here the first dedicated study on JNN applied to a large-scale long-measurement-time experiment with the implementation of a co-magnetometry. In this study, we derive surface- and v… ▽ More

    Submitted 9 July, 2021; v1 submitted 2 February, 2021; originally announced February 2021.

    Journal ref: Phys. Rev. A 103, 062801 (2021)

  15. arXiv:2101.08730  [pdf, other

    physics.ins-det nucl-ex

    The design of the n2EDM experiment

    Authors: N. J. Ayres, G. Ban, L. Bienstman, G. Bison, K. Bodek, V. Bondar, T. Bouillaud, E. Chanel, J. Chen, P. -J. Chiu, B. Clément, C. Crawford, M. Daum, B. Dechenaux, C. B. Doorenbos, S. Emmenegger, L. Ferraris-Bouchez, M. Fertl, A. Fratangelo, P. Flaux, D. Goupillière, W. C. Griffith, Z. D. Grujic, P. G. Harris, K. Kirch , et al. (36 additional authors not shown)

    Abstract: We present the design of a next-generation experiment, n2EDM, currently under construction at the ultracold neutron source at the Paul Scherrer Institute (PSI) with the aim of carrying out a high-precision search for an electric dipole moment of the neutron. The project builds on experience gained with the previous apparatus operated at PSI until 2017, and is expected to deliver an order of magnit… ▽ More

    Submitted 22 January, 2021; v1 submitted 21 January, 2021; originally announced January 2021.

    Journal ref: Eur. Phys. J. C 81, 512 (2021)

  16. arXiv:2009.11046  [pdf, other

    hep-ph nucl-ex quant-ph

    A search for neutron to mirror-neutron oscillations

    Authors: C. Abel, N. J. Ayres, G. Ban, G. Bison, K. Bodek, V. Bondar, E. Chanel, P. -J. Chiu, C. Crawford, M. Daum, R. T. Dinani, S. Emmenegger, P. Flaux, L. Ferraris-Bouchez, W. C. Griffith, Z. D. Grujic, N. Hild, K. Kirch, H. -C. Koch, P. A. Koss, A. Kozela, J. Krempel, B. Lauss, T. Lefort, A. Leredde , et al. (18 additional authors not shown)

    Abstract: It has been proposed that there could be a mirror copy of the standard model particles, restoring the parity symmetry in the weak interaction on the global level. Oscillations between a neutral standard model particle, such as the neutron, and its mirror counterpart could potentially answer various standing issues in physics today. Astrophysical studies and terrestrial experiments led by ultracold… ▽ More

    Submitted 19 November, 2020; v1 submitted 23 September, 2020; originally announced September 2020.

    Comments: Submitted to Physics Letters B, 9 pages, 3 figures

  17. Demonstration of Muon-Beam Transverse Phase-Space Compression

    Authors: A. Antognini, N. J. Ayres, I. Belosevic, V. Bondar, A. Eggenberger, M. Hildebrandt, R. Iwai, D. M. Kaplan, K. S. Khaw, K. Kirch, A. Knecht, A. Papa, C. Petitjean, T. J. Phillips, F. M. Piegsa, N. Ritjoho, A. Stoykov, D. Taqqu, G. Wichmann

    Abstract: We demonstrate efficient transverse compression of a 12.5 MeV/c muon beam stopped in a helium gas target featuring a vertical density gradient and crossed electric and magnetic fields. The muon stop distribution extending vertically over 14 mm was reduced to a 0.25 mm size (RMS) within 3.5 $μ$s. The simulation including cross sections for low-energy $μ^+$-$\text{He}$ elastic and charge exchange (… ▽ More

    Submitted 28 September, 2020; v1 submitted 26 March, 2020; originally announced March 2020.

    Comments: 6 pages, 7 figures; accepted for publication in Phys. Rev. Lett

    Journal ref: Phys. Rev. Lett. 125, 164802 (2020)

  18. arXiv:2001.11966  [pdf, other

    hep-ex nucl-ex physics.ins-det

    Measurement of the permanent electric dipole moment of the neutron

    Authors: C. Abel, S. Afach, N. J. Ayres, C. A. Baker, G. Ban, G. Bison, K. Bodek, V. Bondar, M. Burghoff, E. Chanel, Z. Chowdhuri, P. -J. Chiu, B. Clement, C. B. Crawford, M. Daum, S. Emmenegger, L. Ferraris-Bouchez, M. Fertl, P. Flaux, B. Franke, A. Fratangelo, P. Geltenbort, K. Green, W. C. Griffith, M. van der Grinten , et al. (59 additional authors not shown)

    Abstract: We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons (UCN). Our measurement stands in the long history of EDM experiments probing physics violating time reversal invariance. The salient features of this experiment were the use of a Hg-19… ▽ More

    Submitted 31 January, 2020; originally announced January 2020.

    Comments: 5 pages, 4 figures, submitted to PRL on 18.12.2019

    Journal ref: Phys. Rev. Lett. 124, 081803 (2020)

  19. arXiv:1912.09244  [pdf, other

    physics.data-an hep-ex nucl-ex physics.ins-det

    Data blinding for the nEDM experiment at PSI

    Authors: N. J. Ayres, G. Ban, G. Bison, K. Bodek, V. Bondar, E. Chanel, P. -J. Chiu, C. Crawford, M. Daum, S. Emmenegger, L. Ferraris-Bouchez, P. Flaux, P. G Harris, Z. Grujić, N. Hild, J. Hommet, B. Lauss, T. Lefort, Y. Lemiere, M. Kasprzak, Y. Kermaidic, K. Kirch, S. Komposch, A. Kozela, J. Krempel , et al. (20 additional authors not shown)

    Abstract: Psychological bias towards, or away from, a prior measurement or a theory prediction is an intrinsic threat to any data analysis. While various methods can be used to avoid the bias, e.g. actively not looking at the result, only data blinding is a traceable and thus trustworthy method to circumvent the bias and to convince a public audience that there is not even an accidental psychological bias.… ▽ More

    Submitted 5 October, 2020; v1 submitted 19 December, 2019; originally announced December 2019.

  20. arXiv:1912.04631  [pdf, other

    physics.atom-ph hep-ex nucl-ex

    Optically Pumped Cs Magnetometers Enabling a High-Sensitivity Search for the Neutron Electric Dipole Moment

    Authors: C. Abel, S. Afach, N. J. Ayres, G. Ban, G. Bison, K. Bodek, V. Bondar, E. Chanel, P. -J. Chiu, C. B. Crawford, Z. Chowdhuri, M. Daum, S. Emmenegger, L. Ferraris-Bouchez, M. Fertl, B. Franke, W. C. Griffith, Z. D. Grujić, L. Hayen, V. Hélaine, N. Hild, M. Kasprzak, Y. Kermaidic, K. Kirch, P. Knowles , et al. (35 additional authors not shown)

    Abstract: An array of sixteen laser-pumped scalar Cs magnetometers was part of the neutron electric dipole moment (nEDM) experiment taking data at the Paul Scherrer Institute in 2015 and 2016. It was deployed to measure the gradients of the experiment's magnetic field and to monitor their temporal evolution. The originality of the array lies in its compact design, in which a single near-infrared diode laser… ▽ More

    Submitted 28 April, 2020; v1 submitted 10 December, 2019; originally announced December 2019.

    Journal ref: Phys. Rev. A 101, 053419 (2020)

  21. muCool: A novel low-energy muon beam for future precision experiments

    Authors: I. Belosevic, A. Antognini, Y. Bao, A. Eggenberger, M. Hildebrandt, R. Iwai, D. M. Kaplan, K. S. Khaw, K. Kirch, A. Knecht, A. Papa, C. Petitjean, T. J. Phillips, F. M. Piegsa, N. Ritjoho, A. Stoykov, D. Taqqu, G. Wichmann

    Abstract: Experiments with muons ($μ^{+}$) and muonium atoms ($μ^{+}e^{-}$) offer several promising possibilities for testing fundamental symmetries. Examples of such experiments include search for muon electric dipole moment, measurement of muon $g-2$ and experiments with muonium from laser spectroscopy to gravity experiments. These experiments require high quality muon beams with small transverse size and… ▽ More

    Submitted 15 January, 2019; originally announced January 2019.

    Comments: 8 pages, 5 figures, TCP 2018 conference proceedings

    Journal ref: Hyperfine Interact (2019) 240: 41

  22. arXiv:1812.03987  [pdf, other

    physics.ins-det hep-ex

    The Pulsed Neutron Beam EDM Experiment

    Authors: E. Chanel, Z. Hodge, D. Ries, I. Schulthess, M. Solar, T. Soldner, O. Stalder, J. Thorne, F. M. Piegsa

    Abstract: We report on the Beam EDM experiment, which aims to employ a pulsed cold neutron beam to search for an electric dipole moment instead of the established use of storable ultracold neutrons. We present a brief overview of the basic measurement concept and the current status of our proof-of-principle Ramsey apparatus.

    Submitted 12 March, 2019; v1 submitted 8 December, 2018; originally announced December 2018.

  23. Novel Concept for a Neutron Electric Charge Measurement using a Talbot-Lau Interferometer at a Pulsed Source

    Authors: Florian M. Piegsa

    Abstract: A concept to measure the neutron electric charge is presented which employs a precision Talbot-Lau interferometer in a high-intensity pulsed neutron beam. It is demonstrated that the sensitivity for a neutron charge measurement can be improved by up to two orders of magnitude compared to the current best direct experimental limit.

    Submitted 8 December, 2018; originally announced December 2018.

  24. arXiv:1811.11692  [pdf, other

    physics.ins-det nucl-ex

    ANNI - A pulsed cold neutron beam facility for particle physics at the ESS

    Authors: Torsten Soldner, Hartmut Abele, Gertrud Konrad, Bastian Märkisch, Florian M. Piegsa, Ulrich Schmidt, Camille Theroine, Pablo Torres Sánchez

    Abstract: Pulsed beams have tremendous advantages for precision experiments with cold neutrons. In order to minimise and measure systematic effects, they are used at continuous sources in spite of the related substantial decrease in intensity. At the European Spallation Source ESS these experiments will profit from the pulse structure of the source and its 50 times higher peak brightness compared to the mos… ▽ More

    Submitted 28 November, 2018; originally announced November 2018.

    Comments: 8 pages, 4 figures; submitted to the Proceedings of the International Workshop on Particle Physics at Neutron Sources PPNS 2018, Grenoble, France, May 24-26, 2018

    Journal ref: EPJ Web of Conferences 219, 10003 (2019)

  25. muCool: A next step towards efficient muon beam compression

    Authors: A. Antognini, Y. Bao, I. Belosevic, A. Eggenberger, M. Hildebrandt, R. Iwai, D. M. Kaplan, K. S. Khaw, K. Kirch, A. Knecht, A. Papa, C. Petitjean, T. J. Phillips, F. M. Piegsa, N. Ritjoho, A. Stoykov, D. Taqqu, G. Wichmann

    Abstract: A novel device to compress the phase space of a muon beam by a factor of $10^{10}$ with a $10^{-3}$ efficiency is under development. A surface muon beam is stopped in a helium gas target consisting of several compression stages, wherein strong electric and magnetic fields are applied. The spatial extent of the stopped muon swarm is decreased by means of these fields until muons with eV energy are… ▽ More

    Submitted 20 November, 2018; originally announced November 2018.

    Comments: 8 pages, 11 figures

    Journal ref: Eur. Phys. J. C (2019) 79: 430

  26. arXiv:1811.06085  [pdf, other

    physics.ins-det hep-ex

    Magnetic field uniformity in neutron electric dipole moment experiments

    Authors: C. Abel, N. Ayres, T. Baker, G. Ban, G. Bison, K. Bodek, V. Bondar, C. Crawford, P. -J. Chiu, E. Chanel, Z. Chowdhuri, M. Daum, B. Dechenaux, S. Emmenegger, L. Ferraris-Bouchez, P. Flaux, P. Geltenbort, K. Green, W. C. Griffith, M. van der Grinten, P. G. Harris, R. Henneck, N. Hild, P. Iaydjiev, S. N. Ivanov , et al. (31 additional authors not shown)

    Abstract: Magnetic field uniformity is of the utmost importance in experiments to measure the electric dipole moment of the neutron. A general parametrization of the magnetic field in terms of harmonic polynomial modes is proposed, going beyond the linear-gradients approximation. We review the main undesirable effects of non-uniformities: depolarization of ultracold neutrons, and Larmor frequency shifts of… ▽ More

    Submitted 30 August, 2019; v1 submitted 13 November, 2018; originally announced November 2018.

    Journal ref: Phys. Rev. A 99, 042112 (2019)

  27. arXiv:1811.04012  [pdf, other

    physics.ins-det nucl-ex

    nEDM experiment at PSI: data-taking strategy and sensitivity of the dataset

    Authors: C. Abel, N. J. Ayres, G. Ban, G. Bison, K. Bodek, V. Bondar, E. Chanel, P. -J. Chiu, M. Daum, S. Emmenegger, L. Ferraris-Bouchez, P. Flaux, W. C. Griffith P. G. Harris, N. Hild, Y. Kermaidic, K. Kirch, P. A. Koss, J. Krempel, B. Lauss, T. Lefort, Y. Lemiere, A. Leredde, P. Mohanmurthy, M. Musgrave, O. Naviliat-Cuncic , et al. (18 additional authors not shown)

    Abstract: We report on the strategy used to optimize the sensitivity of our search for a neutron electric dipole moment at the Paul Scherrer Institute. Measurements were made upon ultracold neutrons stored within a single chamber at the heart of our apparatus. A mercury cohabiting magnetometer together with an array of cesium magnetometers were used to monitor the magnetic field, which was controlled and sh… ▽ More

    Submitted 9 November, 2018; originally announced November 2018.

    Comments: Submitted as a web of conference proceedings paper for PPNS2018

  28. arXiv:1811.02340  [pdf, other

    physics.ins-det hep-ex nucl-ex

    The n2EDM experiment at the Paul Scherrer Institute

    Authors: C. Abel, N. J. Ayres, G. Ban, G. Bison, K. Bodek, V. Bondar, E. Chanel, P. -J. Chiu, B. Clement, C. Crawford, M. Daum, S. Emmenegger, P. Flaux, L. Ferraris-Bouchez, W. C. Griffith, Z. D. Grujić, P. G. Harris, W. Heil, N. Hild, K. Kirch, P. A. Koss, A. Kozela, J. Krempel, B. Lauss, T. Lefort , et al. (23 additional authors not shown)

    Abstract: We present the new spectrometer for the neutron electric dipole moment (nEDM) search at the Paul Scherrer Institute (PSI), called n2EDM. The setup is at room temperature in vacuum using ultracold neutrons. n2EDM features a large UCN double storage chamber design with neutron transport adapted to the PSI UCN source. The design builds on experience gained from the previous apparatus operated at PSI… ▽ More

    Submitted 27 February, 2019; v1 submitted 6 November, 2018; originally announced November 2018.

    Comments: Submitted as a web of conference proceedings paper

  29. arXiv:1811.01906  [pdf, other

    nucl-ex physics.ins-det

    Statistical sensitivity of the nEDM apparatus at PSI to neutron mirror-neutron oscillations

    Authors: C. Abel, N. Ayres, G. Bison, K. Bodek, V. Bondar, P. -J. Chiu, M. Daum, S. Emmenegger, P. Flaux, L. Ferraris-Bouchez, W. C. Griffth, N. Hild, K. Kirch, P. A. Koss, A. Kozela, J. Krempel, B. Lauss, T. Lefort, A. Leredde, P. Mohanmurthy, O. Naviliat-Cuncic, D. Pais, F. M. Piegsa, G. Pignol, M. Rawlik , et al. (11 additional authors not shown)

    Abstract: The neutron and its hypothetical mirror counterpart, a sterile state degenerate in mass, could spontaneously mix in a process much faster than the neutron $β$-decay. Two groups have performed a series of experiments in search of neutron - mirror-neutron ($n-n'$) oscillations. They reported no evidence, thereby setting stringent limits on the oscillation time $τ_{nn'}$. Later, these data sets have… ▽ More

    Submitted 19 December, 2019; v1 submitted 5 November, 2018; originally announced November 2018.

    Comments: Proceedings of International Workshop on Particle Physics at Neutron Sources, PPNS-2018; May 24-26, 2018, LPSC, Grenoble, France; Abs. ID: 28 and 60. 10 Pages, 9 Figures

  30. arXiv:1804.05838  [pdf, other

    physics.ins-det hep-ex nucl-ex physics.atom-ph

    Demonstration of sensitivity increase in mercury free-spin-precession magnetometers due to laser-based readout for neutron electric dipole moment searches

    Authors: G. Ban, G. Bison, K. Bodek, M. Daum, M. Fertl, B. Franke, Z. D. Grujić, W. Heil, M. Horras, M. Kasprzak, Y. Kermaidic, K. Kirch, H. -C. Koch, S. Komposch, A. Kozel, J. Krempel, B. Lauss, T. Lefort, A. Mtchedlishvili, G. Pignol, F. M. Piegsa, P. Prashanth, G. Quéméner, M. Rawlik, D. Rebreyend , et al. (9 additional authors not shown)

    Abstract: We report on a laser based $^{199}$Hg co-magnetometer deployed in an experiment searching for a permanent electric dipole moment of the neutron. We demonstrate a more than five times increased signal to-noise-ratio in a direct comparison measurement with its $^{204}$Hg discharge bulb-based predecessor. An improved data model for the extraction of important system parameters such as the degrees of… ▽ More

    Submitted 16 April, 2018; originally announced April 2018.

    Journal ref: NIM A 896 (2018) 129-138

  31. arXiv:1709.04681  [pdf, other

    physics.ins-det

    A simple method of coil design

    Authors: M. Rawlik, C. Crawford, A. Eggenberger, K. Kirch, J. Krempel, F. M. Piegsa, G. Quéméner

    Abstract: In this article we present a method to design a coil producing an arbitrarily shaped magnetic field by restricting the path of the coil's wires to a regular grid. The solution is then found by a simple least squares minimum. We discuss practical applications, in particular in the active magnetic field stabilization system of the neutron electric dipole moment experiment at the Paul Scherrer Instit… ▽ More

    Submitted 14 September, 2017; originally announced September 2017.

  32. High-power closed-cycle $^4$He cryostat with top-loading sample exchange

    Authors: F. M. Piegsa, B. van den Brandt, K. Kirch

    Abstract: We report on the development of a versatile cryogen-free laboratory cryostat based upon a commercial pulse tube cryocooler. It provides enough cooling power for continuous recondensation of circulating $^4$He gas at a condensation pressure of approximately 250~mbar. Moreover, the cryostat allows for exchange of different cryostat-inserts as well as fast and easy "wet" top-loading of samples direct… ▽ More

    Submitted 30 August, 2017; originally announced August 2017.

  33. arXiv:1708.06367  [pdf, other

    hep-ph astro-ph.CO nucl-ex nucl-th physics.atom-ph

    Search for axion-like dark matter through nuclear spin precession in electric and magnetic fields

    Authors: C. Abel, N. J. Ayres, G. Ban, G. Bison, K. Bodek, V. Bondar, M. Daum, M. Fairbairn, V. V. Flambaum, P. Geltenbort, K. Green, W. C. Griffith, M. van der Grinten, Z. D. Grujić, P. G. Harris, N. Hild, P. Iaydjiev, S. N. Ivanov, M. Kasprzak, Y. Kermaidic, K. Kirch, H. -C. Koch, S. Komposch, P. A. Koss, A. Kozela , et al. (23 additional authors not shown)

    Abstract: We report on a search for ultra-low-mass axion-like dark matter by analysing the ratio of the spin-precession frequencies of stored ultracold neutrons and $^{199}$Hg atoms for an axion-induced oscillating electric dipole moment of the neutron and an axion-wind spin-precession effect. No signal consistent with dark matter is observed for the axion mass range… ▽ More

    Submitted 21 August, 2017; originally announced August 2017.

    Journal ref: Phys. Rev. X 7, 041034 (2017)

  34. arXiv:1606.07432  [pdf, other

    physics.ins-det nucl-ex

    Ultracold neutron detection with 6Li-doped glass scintillators, NANOSC: a fast ultracold neutron detector for the nEDM experiment at the Paul Scherrer Institute

    Authors: G. Ban, G. Bison, K. Bodek, Z. Chowdhuri, P. Geltenbort, W. C. Griffith, V. Hélaine, R. Henneck, M. Kasprzak, Y. Kermaidic, K. Kirch, S. Komposch, P. A. Koss, A. Kozela, J. Krempel, B. Lauss, T. Lefort, Y. Lemière, A. Mtchedlishvili, M. Musgrave, O. Naviliat-Cuncic, F. M. Piegsa, E. Pierre, G. Pignol, G. Quéméner , et al. (10 additional authors not shown)

    Abstract: This paper summarizes the results from measurements aiming to characterize ultracold neutron detection with 6Li-doped glass scintillators. Single GS10 or GS20 scintillators, with a thickness of 100-200 micrometer, fulfill the ultracold neutron detection requirements with an acceptable neutron-gamma discrimination. This discrimination is clearly improved with a stack of two scintillators: a 6Li-dep… ▽ More

    Submitted 23 June, 2016; originally announced June 2016.

    Comments: 14 pages, 12 figures, regular article submitted for publication

    ACM Class: J.2

  35. arXiv:1603.06849  [pdf, other

    physics.data-an physics.ins-det

    Statistical Uncertainty in Quantitative Neutron Radiography

    Authors: Florian M. Piegsa, Anders P. Kaestner, Aldo Antognini, Andreas Eggenberger, Klaus Kirch, Gunther Wichmann

    Abstract: We demonstrate a novel procedure to calibrate neutron detection systems commonly used in standard neutron radiography. This calibration allows determining the uncertainties due to Poisson-like neutron counting statistics for each individual pixel of a radiographic image. The obtained statistical errors are necessary in order to perform a correct quantitative analysis. This fast and convenient meth… ▽ More

    Submitted 28 April, 2017; v1 submitted 22 March, 2016; originally announced March 2016.

    Journal ref: Eur. Phys. J. Appl. Phys. (2017) 78: 10702

  36. Neutron phase spin echo

    Authors: Florian M. Piegsa, Patrick Hautle, Christian Schanzer

    Abstract: A novel neutron spin resonance technique is presented based on the well-know neutron spin echo method. In a first proof-of-principle measurement using a monochromatic neutron beam, it is demonstrated that relative velocity changes of down to a precision of $4 \times 10^{-7}$ can be resolved, corresponding to an energy resolution of better than 3~neV. Currently, the sensitivity is only limited by c… ▽ More

    Submitted 22 March, 2016; originally announced March 2016.

    Journal ref: Phys. Rev. C 93 (2016) 045501

  37. arXiv:1509.04411  [pdf, other

    hep-ex physics.ins-det

    A Revised Experimental Upper Limit on the Electric Dipole Moment of the Neutron

    Authors: J. M. Pendlebury, S. Afach, N. J. Ayres, C. A. Baker, G. Ban, G. Bison, K. Bodek, M. Burghoff, P. Geltenbort, K. Green, W. C. Griffith, M. van der Grinten, Z. D. Grujic, P. G. Harris, V. Helaine, P. Iaydjiev, S. N. Ivanov, M. Kasprzak, Y. Kermaidic, K. Kirch, H. -C. Koch, S. Komposch, A. Kozela, J. Krempel, B. Lauss , et al. (25 additional authors not shown)

    Abstract: We present for the first time a detailed and comprehensive analysis of the experimental results that set the current world sensitivity limit on the magnitude of the electric dipole moment (EDM) of the neutron. We have extended and enhanced our earlier analysis to include recent developments in the understanding of the effects of gravity in depolarizing ultracold neutrons (UCN); an improved calcula… ▽ More

    Submitted 13 October, 2015; v1 submitted 15 September, 2015; originally announced September 2015.

    Comments: 23 pages, 19 figures. Authorship list changed to put J.M. Pendlebury first. Other very minor edits

    Journal ref: Phys. Rev. D 92, 092003 (2015)

  38. arXiv:1507.08523  [pdf, ps, other

    physics.atom-ph

    A highly stable atomic vector magnetometer based on free spin precession

    Authors: S. Afach, G. Ban, G. Bison, K. Bodek, Z. Chowdhuri, Z. D. Grujic, L. Hayen, V. Helaine, M. Kasprzak, K. Kirch, P. Knowles, H. -C. Koch, S. Komposch, A. Kozela, J. Krempel, B. Lauss, T. Lefort, Y. Lemiere, A. Mtchedlishvili, O. Naviliat-Cuncic, F. M. Piegsa, P. N. Prashanth, G. Quemener, M. Rawlik, D. Ries , et al. (9 additional authors not shown)

    Abstract: We present a magnetometer based on optically pumped Cs atoms that measures the magnitude and direction of a 1 $μ$T magnetic field. Multiple circularly polarized laser beams were used to probe the free spin precession of the Cs atoms. The design was optimized for long-time stability and achieves a scalar resolution better than 300 fT for integration times ranging from 80 ms to 1000 s. The best scal… ▽ More

    Submitted 30 July, 2015; originally announced July 2015.

    Journal ref: Optics Express Vol. 23, Issue 17, pp. 22108-22115 (2015)

  39. arXiv:1507.07475  [pdf, other

    physics.ins-det nucl-ex

    Ultracold neutron production and up-scattering in superfluid helium between 1.1 K and 2.4 K

    Authors: K. K. H. Leung, S. Ivanov, F. M. Piegsa, M. Simson, O. Zimmer

    Abstract: Ultracold neutrons (UCNs) were produced in a 4 liter volume of superfluid helium using the PF1B cold neutron beam facility at the Institut Laue-Langevin and then extracted to a detector at room temperature. With a converter temperature of 1.08 K the number of accumulated UCNs was counted to be $91,\!700 \pm 300$. From this, we derive a volumetric UCN production rate of… ▽ More

    Submitted 22 February, 2016; v1 submitted 27 July, 2015; originally announced July 2015.

    Journal ref: Phys. Rev. C 93, 025501 (2016)

  40. arXiv:1506.06563  [pdf, other

    physics.ins-det hep-ex

    Gravitational Depolarization of Ultracold Neutrons: Comparison with Data

    Authors: S. Afach, N. J. Ayres, C. A. Baker, G. Ban, G. Bison, K. Bodek, M. Fertl, B. Franke, P. Geltenbort, K. Green, W. C. Griffith, M. van der Grinten, Z. D. Grujic, P. G. Harris, W. Heil, V. Helaine, P. Iaydjiev, S. N. Ivanov, M. Kasprzak, Y. Kermaidic, K. Kirch, H. -C. Koch, S. Komposch, A. Kozela, J. Krempel , et al. (25 additional authors not shown)

    Abstract: We compare the expected effects of so-called gravitationally enhanced depolarization of ultracold neutrons to measurements carried out in a spin-precession chamber exposed to a variety of vertical magnetic-field gradients. In particular, we have investigated the dependence upon these field gradients of spin depolarization rates and also of shifts in the measured neutron Larmor precession frequency… ▽ More

    Submitted 26 August, 2015; v1 submitted 22 June, 2015; originally announced June 2015.

    Comments: 10 pages, 6 figures. Updated: section added about implications for current nEDM limit

    Journal ref: Phys. Rev. D 92, 052008 (2015)

  41. arXiv:1506.00446  [pdf, other

    physics.ins-det nucl-ex

    Observation of gravitationally induced vertical striation of polarized ultracold neutrons by spin-echo spectroscopy

    Authors: S. Afach, N. J. Ayres, G. Ban, G. Bison, K. Bodek, Z. Chowdhuri, M. Daum, M. Fertl, B. Franke, W. C. Griffith, Z. D. Grujić, P. G. Harris, W. Heil, V. Hélaine, M. Kasprzak, Y. Kermaidic, K. Kirch, P. Knowles, H. -C. Koch, S. Komposch, A. Kozela, J. Krempel, B. Lauss, T. Lefort, Y. Lemière , et al. (23 additional authors not shown)

    Abstract: We describe a spin-echo method for ultracold neutrons (UCNs) confined in a precession chamber and exposed to a $|B_0|=1~\text{μT}$ magnetic field. We have demonstrated that the analysis of UCN spin-echo resonance signals in combination with knowledge of the ambient magnetic field provides an excellent method by which to reconstruct the energy spectrum of a confined ensemble of neutrons. The method… ▽ More

    Submitted 8 September, 2015; v1 submitted 1 June, 2015; originally announced June 2015.

    Comments: 7 pages 5 figures, accepted by PRL, September, 08 2015

    Journal ref: Phys. Rev. Lett. 115, 162502 (2015)

  42. arXiv:1503.08651  [pdf, other

    physics.atom-ph nucl-ex

    Measurement of a false electric dipole moment signal from $^{199}$Hg atoms exposed to an inhomogeneous magnetic field

    Authors: S. Afach, C. A. Baker, G. Ban, G. Bison, K. Bodek, Z. Chowdhuri, M. Daum, M. Fertl, B. Franke, P. Geltenbort, K. Green, M. G. D. van der Grinten, Z. Grujic, P. G. Harris, W. Heil, V. Hélaine, R. Henneck, M. Horras, P. Iaydjiev, S. N. Ivanov, M. Kasprzak, Y. Kermaïdic, K. Kirch, P. Knowles, H. -C. Koch , et al. (24 additional authors not shown)

    Abstract: We report on the measurement of a Larmor frequency shift proportional to the electric-field strength for $^{199}{\rm Hg}$ atoms contained in a volume permeated with aligned magnetic and electric fields. This shift arises from the interplay between the inevitable magnetic field gradients and the motional magnetic field. The proportionality to electric-field strength makes it apparently similar to a… ▽ More

    Submitted 3 August, 2015; v1 submitted 30 March, 2015; originally announced March 2015.

    Journal ref: Eur. Phys. J. D (2015) 69:225

  43. arXiv:1502.06876  [pdf, other

    physics.ins-det nucl-ex

    A device for simultaneous spin analysis of ultracold neutrons

    Authors: S. Afach, G. Ban, G. Bison, K. Bodek, Z. Chowdhuri, M. Daum, M. Fertl, B. Franke, P. Geltenbort, Z. D. Grujić, L. Hayen, V. Hélaine, R. Henneck, M. Kasprzak, Y. Kermaidic, K. Kirch, S. Komposch, A. Kozela, J. Krempel, B. Lauss, T. Lefort, Y. Lemière, A. Mtchedlishvili, O. Naviliat-Cuncic, F. M. Piegsa , et al. (15 additional authors not shown)

    Abstract: We report on the design and first tests of a device allowing for measurement of ultracold neutrons polarisation by means of the simultaneous analysis of the two spin components. The device was developed in the framework of the neutron electric dipole moment experiment at the Paul Scherrer Institute. Individual parts and the entire newly built system have been characterised with ultracold neutrons.… ▽ More

    Submitted 12 October, 2015; v1 submitted 24 February, 2015; originally announced February 2015.

  44. Constraining interactions mediated by axion-like particles with ultracold neutrons

    Authors: S. Afach, G. Ban, G. Bison, K. Bodek, M. Burghoff, M. Daum, M. Fertl, B. Franke, Z. D. Grujić, V. Hélaine, M. Kasprzak, Y. Kermaïdic, K. Kirch, P. Knowles, H. -C. Koch, S. Komposch, A. Kozela, J. Krempel, B. Lauss, T. Lefort, Y. Lemière, A. Mtchedlishvili, O. Naviliat-Cuncic, F. M. Piegsa, G. Pignol , et al. (13 additional authors not shown)

    Abstract: We report a new limit on a possible short range spin-dependent interaction from the precise measurement of the ratio of Larmor precession frequencies of stored ultracold neutrons and $^{199}$Hg atoms confined in the same volume. The measurement was performed in a $\sim$1$μ$ T vertical magnetic holding field with the apparatus searching for a permanent electric dipole moment of the neutron at the P… ▽ More

    Submitted 11 December, 2014; originally announced December 2014.

  45. arXiv:1410.8259  [pdf, other

    nucl-ex physics.atom-ph physics.ins-det

    A measurement of the neutron to 199Hg magnetic moment ratio

    Authors: S. Afach, C. A. Baker, G. Ban, G. Bison, K. Bodek, M. Burghoff, Z. Chowdhuri, M. Daum, M. Fertl, B. Franke, P. Geltenbort, K. Green, M. G. D. van der Grinten, Z. Grujic, P. G. Harris, W. Heil, V. Hélaine, R. Henneck, M. Horras, P. Iaydjiev, S. N. Ivanov, M. Kasprzak, Y. Kermaïdic, K. Kirch, A. Knecht , et al. (29 additional authors not shown)

    Abstract: The neutron gyromagnetic ratio has been measured relative to that of the 199Hg atom with an uncertainty of 0.8 ppm. We employed an apparatus where ultracold neutrons and mercury atoms are stored in the same volume and report the result $γ_{\rm n}/γ_{\rm Hg} = 3.8424574(30)$.

    Submitted 31 October, 2014; v1 submitted 30 October, 2014; originally announced October 2014.

    Journal ref: Physics Letters B 739, 128-132 (2014)

  46. arXiv:1408.6752  [pdf, other

    physics.ins-det nucl-ex physics.atom-ph

    Dynamic stabilization of the magnetic field surrounding the neutron electric dipole moment spectrometer at the Paul Scherrer Institute

    Authors: S. Afach, G. Bison, K. Bodek, F. Burri, Z. Chowdhuri, M. Daum, M. Fertl, B. Franke, Z. Grujic, V. Helaine, R. Henneck, M. Kasprzak, K. Kirch, H. -C. Koch, A. Kozela, J. Krempel, B. Lauss, T. Lefort, Y. Lemiere, M. Meier, O. Naviliat-Cuncic, F. M. Piegsa, G. Pignol, C. Plonka-Spehr, P. N. Prashanth , et al. (12 additional authors not shown)

    Abstract: The Surrounding Field Compensation (SFC) system described in this work is installed around the four-layer Mu-metal magnetic shield of the neutron electric dipole moment spectrometer located at the Paul Scherrer Institute. The SFC system reduces the DC component of the external magnetic field by a factor of about 20. Within a control volume of approximately 2.5m x 2.5m x 3m disturbances of the magn… ▽ More

    Submitted 28 August, 2014; originally announced August 2014.

    Comments: 33 pages, 18 figures

    Journal ref: J. Appl. Phys. 116, 084510 (2014)

  47. arXiv:1404.3527  [pdf, other

    physics.ins-det nucl-ex

    New source for ultracold neutrons at the Institut Laue-Langevin

    Authors: F. M. Piegsa, M. Fertl, S. N. Ivanov, M. Kreuz, K. K. H. Leung, P. Schmidt-Wellenburg, T. Soldner, O. Zimmer

    Abstract: A new intense superthermal source for ultracold neutrons (UCN) has been installed at a dedicated beam line at the Institut Laue-Langevin. Incident neutrons with a wavelength of 0.89 nm are converted to UCN in a five liter volume filled with superfluid $^4$He at a temperature of about 0.7 K. The UCN can be extracted to room temperature experiments. We present the cryogenic setup of the source, a ch… ▽ More

    Submitted 14 April, 2014; originally announced April 2014.

    Journal ref: Phys. Rev. C 90 (2014) 015501

  48. Muon cooling: longitudinal compression

    Authors: Yu Bao, Aldo Antognini, Wilhelm Bertl, Malte Hildebrandt, Kim Siang Khaw, Klaus Kirch, Angela Papa, Claude Petitjean, Florian M. Piegsa, Stefan Ritt, Kamil Sedlak, Alexey Stoykov, David Taqqu

    Abstract: A 10 MeV/c $μ^+$ beam was stopped in helium gas of a few mbar in a magnetic field of 5 T. The muon 'swarm' has been efficiently compressed from a length of 16 cm down to a few mm along the magnetic field axis (longitudinal compression) using electrostatic fields. The simulation reproduces the low energy interactions of slow muons in helium gas. Phase space compression occurs on the order of micros… ▽ More

    Submitted 11 February, 2014; originally announced February 2014.

    Comments: 5 pages, 6 figures

  49. arXiv:1309.1959  [pdf, other

    physics.ins-det nucl-ex

    New Concept for a Neutron Electric Dipole Moment Search using a Pulsed Beam

    Authors: F. M. Piegsa

    Abstract: A concept to search for a neutron electric dipole moment (nEDM) is presented, which employs a pulsed neutron beam instead of the nowadays established use of storable ultracold neutrons (UCN). The technique takes advantage of the high peak flux and the time structure of a next-generation pulsed spallation source like the planned European Spallation Source. It is demonstrated that the sensitivity fo… ▽ More

    Submitted 14 October, 2013; v1 submitted 8 September, 2013; originally announced September 2013.

    Journal ref: Physical Review C 88, 045502 (2013)

  50. arXiv:1210.2606  [pdf, other

    cond-mat.mtrl-sci

    Polarized Neutron Laue Diffraction on a Crystal Containing Dynamically Polarized Proton Spins

    Authors: F. M. Piegsa, M. Karlsson, B. van den Brandt, C. J. Carlile, E. M. Forgan, P. Hautle, J. A. Konter, G. J. McIntyre, O. Zimmer

    Abstract: We report on a polarized-neutron Laue diffraction experiment on a single crystal of neodynium doped lanthanum magnesium nitrate hydrate containing polarized proton spins. By using dynamic nuclear polarization to polarize the proton spins, we demonstrate that the intensities of the Bragg peaks can be enhanced or diminished significantly, whilst the incoherent background, due to proton spin disorder… ▽ More

    Submitted 9 October, 2012; originally announced October 2012.