-
Superfluid-tight cryogenic receiver with continuous sub-Kelvin cooling for EXCLAIM
Authors:
Sumit Dahal,
Peter A. R. Ade,
Christopher J. Anderson,
Alyssa Barlis,
Emily M. Barrentine,
Jeffrey W. Beeman,
Nicholas Bellis,
Alberto D. Bolatto,
Victoria Braianova,
Patrick C. Breysse,
Berhanu T. Bulcha,
Giuseppe Cataldo,
Felipe A. Colazo,
Lee-Roger Chevres-Fernandez,
Chullhee Cho,
Danny S. Chmaytelli,
Jake A. Connors,
Nicholas P. Costen,
Paul W. Cursey,
Negar Ehsan,
Thomas M. Essinger-Hileman,
Jason Glenn,
Joseph E. Golec,
James P. Hays-Wehle,
Larry A. Hess
, et al. (45 additional authors not shown)
Abstract:
The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a balloon-borne telescope designed to survey star formation over cosmological time scales using intensity mapping in the 420 - 540 GHz frequency range. EXCLAIM uses a fully cryogenic telescope coupled to six on-chip spectrometers featuring kinetic inductance detectors (KIDs) to achieve high sensitivity, allowing for fast in…
▽ More
The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a balloon-borne telescope designed to survey star formation over cosmological time scales using intensity mapping in the 420 - 540 GHz frequency range. EXCLAIM uses a fully cryogenic telescope coupled to six on-chip spectrometers featuring kinetic inductance detectors (KIDs) to achieve high sensitivity, allowing for fast integration in dark atmospheric windows. The telescope receiver is cooled to $\approx$ 1.7 K by immersion in a superfluid helium bath and enclosed in a superfluid-tight shell with a meta-material anti-reflection coated silicon window. In addition to the optics and the spectrometer package, the receiver contains the magnetic shielding, the cryogenic segment of the spectrometer readout, and the sub-Kelvin cooling system. A three-stage continuous adiabatic demagnetization refrigerator (CADR) keeps the detectors at 100 mK while a $^4$He sorption cooler provides a 900 mK thermal intercept for mechanical suspensions and coaxial cables. We present the design of the EXCLAIM receiver and report on the flight-like testing of major receiver components, including the superfluid-tight receiver window and the sub-Kelvin coolers.
△ Less
Submitted 4 September, 2024;
originally announced September 2024.
-
Optimization of an Optical Testbed for Characterization of EXCLAIM u-Spec Integrated Spectrometers
Authors:
Maryam Rahmani,
Emily M. Barrentine,
Eric R. Switzer,
Alyssa Barlis,
Ari D. Brown,
Giuseppe Cataldo,
Jake A. Connors,
Negar Ehsan,
Thomas M. Essinger-Hileman,
Henry Grant,
James Hays-Wehle,
Wen-Ting Hsieh,
Vilem Mikula,
S. Harvey Moseley,
Omid Noroozian,
Manuel A. Quijada,
Jessica Patel,
Thomas R. Stevenson,
Carole Tucker,
Kongpop U-Yen,
Carolyn G. Volpert,
Edward J. Wollack
Abstract:
We describe a testbed to characterize the optical response of compact superconducting on-chip spectrometers in development for the Experiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) mission. EXCLAIM is a balloonborne far-infrared experiment to probe the CO and CII emission lines in galaxies from redshift 3.5 to the present. The spectrometer, called u-Spec, comprises a diffraction…
▽ More
We describe a testbed to characterize the optical response of compact superconducting on-chip spectrometers in development for the Experiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) mission. EXCLAIM is a balloonborne far-infrared experiment to probe the CO and CII emission lines in galaxies from redshift 3.5 to the present. The spectrometer, called u-Spec, comprises a diffraction grating on a silicon chip coupled to kinetic inductance detectors (KIDs) read out via a single microwave feedline. We use a prototype spectrometer for EXCLAIM to demonstrate our ability to characterize the spectrometers spectral response using a photomixer source. We utilize an on-chip reference detector to normalize relative to spectral structure from the off-chip optics and a silicon etalon to calibrate the absolute frequency.
△ Less
Submitted 12 December, 2023;
originally announced December 2023.
-
Optical Characterization & Testbed Development for μ-Spec Integrated Spectrometers
Authors:
Maryam Rahmani,
Alyssa Barlis,
Emily M. Barrentine,
Ari D. Brown,
Berhanu T. Bulcha,
Giuseppe Cataldo,
Jake Connors,
Negar Ehsan,
Thomas M. Essinger-Hileman,
Henry Grant,
James Hays-Wehle,
Wen-Ting Hsieh,
Vilem Mikula,
S. Harvey Moseley,
Omid Noroozian,
Trevor R. Oxholm,
Manuel A. Quijada,
Jessica Patel,
Thomas R. Stevenson,
Eric R. Switzer,
Carole Tucker,
Kongpop U-Yen,
Carolyn Volpert,
Edward J. Wollack
Abstract:
This paper describes a cryogenic optical testbed developed to characterize u-Spec spectrometers in a dedicated dilution refrigerator (DR) system. u-Spec is a far-infrared integrated spectrometer that is an analog to a Rowland-type grating spectrometer. It employs a single-crystal silicon substrate with niobium microstrip lines and aluminum kinetic inductance detectors (KIDs). Current designs with…
▽ More
This paper describes a cryogenic optical testbed developed to characterize u-Spec spectrometers in a dedicated dilution refrigerator (DR) system. u-Spec is a far-infrared integrated spectrometer that is an analog to a Rowland-type grating spectrometer. It employs a single-crystal silicon substrate with niobium microstrip lines and aluminum kinetic inductance detectors (KIDs). Current designs with a resolution of 512 are in fabrication for the EXCLAIM (Experiment for Cryogenic Large Aperture Intensity Mapping) balloon mission. The primary spectrometer performance and design parameters are efficiency, NEP, inter-channel isolation, spectral resolution, and frequency response for each channel. Here we present the development and design of an optical characterization facility and preliminary validation of that facility with earlier prototype R=64 devices. We have conducted and describe initial optical measurements of R = 64 devices using a swept photomixer line source. We also discuss the test plan for optical characterization of the EXCLAIM R = 512 u-Spec devices in this new testbed.
△ Less
Submitted 12 August, 2022;
originally announced August 2022.
-
Developing a New Generation of Integrated Micro-Spec Far Infrared Spectrometers for the EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM)
Authors:
Carolyn G. Volpert,
Emily M. Barrentine,
Mona Mirzaei,
Alyssa Barlis,
Alberto D. Bolatto,
Berhanu Bulcha,
Giuseppe Cataldo,
Jake A. Connors,
Nicholas Costen,
Negar Ehsan,
Thomas Essinger-Hileman,
Jason Glenn,
James P. Hays-Wehle,
Larry A. Hess,
Alan J. Kogut,
Harvey Moseley,
Jonas Mugge-Durum,
Omid Noroozian,
Trevor M. Oxholm,
Maryam Rahmani,
Thomas Stevenson,
Eric R. Switzer,
Joseph Watson,
Edward J. Wollack
Abstract:
The current state of far-infrared astronomy drives the need to develop compact, sensitive spectrometers for future space and ground-based instruments. Here we present details of the $\rm μ$-Spec spectrometers currently in development for the far-infrared balloon mission EXCLAIM. The spectrometers are designed to cover the $\rm 555 - 714\ μ$m range with a resolution of $\rm R\ =\ λ/ Δλ =\ 512$ at t…
▽ More
The current state of far-infrared astronomy drives the need to develop compact, sensitive spectrometers for future space and ground-based instruments. Here we present details of the $\rm μ$-Spec spectrometers currently in development for the far-infrared balloon mission EXCLAIM. The spectrometers are designed to cover the $\rm 555 - 714\ μ$m range with a resolution of $\rm R\ =\ λ/ Δλ =\ 512$ at the $\rm 638\ μ$m band center. The spectrometer design incorporates a Rowland grating spectrometer implemented in a parallel plate waveguide on a low-loss single-crystal Si chip, employing Nb microstrip planar transmission lines and thin-film Al kinetic inductance detectors (KIDs). The EXCLAIM $\rm μ$-Spec design is an advancement upon a successful $\rm R = 64\ μ$-Spec prototype, and can be considered a sub-mm superconducting photonic integrated circuit (PIC) that combines spectral dispersion and detection. The design operates in a single $M{=}2$ grating order, allowing one spectrometer to cover the full EXCLAIM band without requiring a multi-order focal plane. The EXCLAIM instrument will fly six spectrometers, which are fabricated on a single 150 mm diameter Si wafer. Fabrication involves a flip-wafer-bonding process with patterning of the superconducting layers on both sides of the Si dielectric. The spectrometers are designed to operate at 100 mK, and will include 355 Al KID detectors targeting a goal of NEP ${\sim}8\times10^{-19}$ $\rm W/\sqrt{Hz}$. We summarize the design, fabrication, and ongoing development of these $\rm μ$-Spec spectrometers for EXCLAIM.
△ Less
Submitted 4 August, 2022;
originally announced August 2022.
-
Operational Optimization to Maximize Dynamic Range in EXCLAIM Microwave Kinetic Inductance Detectors
Authors:
Trevor M. Oxholm,
Eric R. Switzer,
Emily M. Barrentine,
Thomas Essinger-Hileman,
James P. Hays-Wehle,
Philip D. Mauskopf,
Omid Noroozian,
Maryam Rahmani,
Adrian K. Sinclair,
Ryan Stephenson,
Thomas R. Stevenson,
Peter T. Timbie,
Carolyn Volpert,
Eric Weeks
Abstract:
Microwave Kinetic Inductance Detectors (MKIDs) are highly scalable detectors that have demonstrated nearly background-limited sensitivity in the far-infrared from high-altitude balloon-borne telescopes and space-like laboratory environments. In addition, the detectors have a rich design space with many optimizable parameters, allowing highly sensitive measurements over a wide dynamic range. For th…
▽ More
Microwave Kinetic Inductance Detectors (MKIDs) are highly scalable detectors that have demonstrated nearly background-limited sensitivity in the far-infrared from high-altitude balloon-borne telescopes and space-like laboratory environments. In addition, the detectors have a rich design space with many optimizable parameters, allowing highly sensitive measurements over a wide dynamic range. For these reasons, MKIDs were chosen for the Experiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM), a balloon-borne telescope targeting nearly background-limited performance in a high-altitude atmospheric environment from 420-540 GHz. We describe MKID optimization in the specific context of EXCLAIM and provide general results that apply to broader applications. Extending the established approach of tone frequency tracking, we show that readout power optimization enables significant, further improvement in dynamic range.
△ Less
Submitted 28 April, 2022;
originally announced April 2022.
-
Axion Dark Matter
Authors:
C. B. Adams,
N. Aggarwal,
A. Agrawal,
R. Balafendiev,
C. Bartram,
M. Baryakhtar,
H. Bekker,
P. Belov,
K. K. Berggren,
A. Berlin,
C. Boutan,
D. Bowring,
D. Budker,
A. Caldwell,
P. Carenza,
G. Carosi,
R. Cervantes,
S. S. Chakrabarty,
S. Chaudhuri,
T. Y. Chen,
S. Cheong,
A. Chou,
R. T. Co,
J. Conrad,
D. Croon
, et al. (130 additional authors not shown)
Abstract:
Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synerg…
▽ More
Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synergies with astrophysical searches and advances in instrumentation including quantum-enabled readout, high-Q resonators and cavities and large high-field magnets. This white paper outlines a clear roadmap to discovery, and shows that the US is well-positioned to be at the forefront of the search for axion dark matter in the coming decade.
△ Less
Submitted 29 March, 2023; v1 submitted 28 March, 2022;
originally announced March 2022.
-
New Horizons: Scalar and Vector Ultralight Dark Matter
Authors:
D. Antypas,
A. Banerjee,
C. Bartram,
M. Baryakhtar,
J. Betz,
J. J. Bollinger,
C. Boutan,
D. Bowring,
D. Budker,
D. Carney,
G. Carosi,
S. Chaudhuri,
S. Cheong,
A. Chou,
M. D. Chowdhury,
R. T. Co,
J. R. Crespo López-Urrutia,
M. Demarteau,
N. DePorzio,
A. V. Derbin,
T. Deshpande,
M. D. Chowdhury,
L. Di Luzio,
A. Diaz-Morcillo,
J. M. Doyle
, et al. (104 additional authors not shown)
Abstract:
The last decade has seen unprecedented effort in dark matter model building at all mass scales coupled with the design of numerous new detection strategies. Transformative advances in quantum technologies have led to a plethora of new high-precision quantum sensors and dark matter detection strategies for ultralight ($<10\,$eV) bosonic dark matter that can be described by an oscillating classical,…
▽ More
The last decade has seen unprecedented effort in dark matter model building at all mass scales coupled with the design of numerous new detection strategies. Transformative advances in quantum technologies have led to a plethora of new high-precision quantum sensors and dark matter detection strategies for ultralight ($<10\,$eV) bosonic dark matter that can be described by an oscillating classical, largely coherent field. This white paper focuses on searches for wavelike scalar and vector dark matter candidates.
△ Less
Submitted 28 March, 2022;
originally announced March 2022.
-
Dual-Resonator Kinetic-Inductance Detector for Distinction between Signal and 1/f Frequency Noise
Authors:
N. Foroozani,
B. Sarabi,
S. H. Moseley,
T. Stevenson,
E. J. Wollack,
O. Noroozian,
K. D. Osborn
Abstract:
Astronomical Kinetic Inductance Detectors (KIDs), similar to quantum information devices, experience performance limiting noise from materials. In particular, 1/f (frequency) noise can be a dominant noise mechanism, which arises from Two-Level System defects (TLSs) in the circuit dielectrics and material interfaces. Here we present a Dual-Resonator KID (DuRKID), which is designed for improved sign…
▽ More
Astronomical Kinetic Inductance Detectors (KIDs), similar to quantum information devices, experience performance limiting noise from materials. In particular, 1/f (frequency) noise can be a dominant noise mechanism, which arises from Two-Level System defects (TLSs) in the circuit dielectrics and material interfaces. Here we present a Dual-Resonator KID (DuRKID), which is designed for improved signal to noise (or noise equivalent power) relative to 1/f-noise limited KIDs. We first show the DuRKID schematic, fabricated circuit, and we follow with a description of the intended operation, first measurements, theory, and discussion. The circuit consists of two superconducting resonators sharing an electrical capacitance bridge of 4 capacitors, each of which hosts TLSs. The device is intended to operate using hybridization of the modes, which causes TLSs to either couple to one mode or the other, depending upon which capacitor they reside in. In contrast, the intended KID signal is directed to an inductor, and due to hybridization this causes correlated frequency changes in both (hybridized) modes. Therefore, one can distinguish photon signal from TLS frequency noise. To achieve hybridization, a TiN inductor is current biased to allow tuning of one bare resonator mode into degeneracy with the other and measurements show that the intended resonator modes frequency tune and hybridize as expected. The interresonator coupling and unintentional coupling of the 2 resonators to transmission lines are also characterized in measurements. In the theory, based on a quantum-information-science modes, we calculate the 4-port S parameters and simulate the 1/f frequency noise of the device. The study reveals that the DuRKID can exhibit a large and fundamental performance advantage over 1/f-noise-limited KID detectors.
△ Less
Submitted 12 December, 2023; v1 submitted 23 February, 2022;
originally announced February 2022.
-
Broadband solenoidal haloscope for terahertz axion detection
Authors:
Jesse Liu,
Kristin Dona,
Gabe Hoshino,
Stefan Knirck,
Noah Kurinsky,
Matthew Malaker,
David W. Miller,
Andrew Sonnenschein,
Mohamed H. Awida,
Peter S. Barry,
Karl K. Berggren,
Daniel Bowring,
Gianpaolo Carosi,
Clarence Chang,
Aaron Chou,
Rakshya Khatiwada,
Samantha Lewis,
Juliang Li,
Sae Woo Nam,
Omid Noroozian,
Tony X. Zhou
Abstract:
We introduce the Broadband Reflector Experiment for Axion Detection (BREAD) conceptual design and science program. This haloscope plans to search for bosonic dark matter across the [10$^{-3}$, 1] eV ([0.24, 240] THz) mass range. BREAD proposes a cylindrical metal barrel to convert dark matter into photons, which a novel parabolic reflector design focuses onto a photosensor. This unique geometry en…
▽ More
We introduce the Broadband Reflector Experiment for Axion Detection (BREAD) conceptual design and science program. This haloscope plans to search for bosonic dark matter across the [10$^{-3}$, 1] eV ([0.24, 240] THz) mass range. BREAD proposes a cylindrical metal barrel to convert dark matter into photons, which a novel parabolic reflector design focuses onto a photosensor. This unique geometry enables enclosure in standard cryostats and high-field solenoids, overcoming limitations of current dish antennas. A pilot 0.7 m$^{2}$ barrel experiment planned at Fermilab is projected to surpass existing dark photon coupling constraints by over a decade with one-day runtime. Axion sensitivity requires $<10^{-20}$ W/$\sqrt{\textrm{Hz}}$ sensor noise equivalent power with a 10 T solenoid and 10 m$^{2}$ barrel. We project BREAD sensitivity for various sensor technologies and discuss future prospects.
△ Less
Submitted 24 March, 2022; v1 submitted 23 November, 2021;
originally announced November 2021.
-
μ-Spec Spectrometers for the EXCLAIM Instrument
Authors:
Mona Mirzaei,
Emily M. Barrentine,
Berhanu T. Bulcha,
Giuseppe Cataldo,
Jake A. Connors,
Negar Ehsan,
Thomas M. Essinger-Hileman,
Larry A. Hess,
Jonas W. Mugge-Durum,
Omid Noroozian,
Trevor M. Oxholm,
Thomas R. Stevenson,
Eric R. Switzer,
Carolyn G. Volpert,
Edward J. Wollack
Abstract:
The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument that will map carbon monoxide and singly-ionized carbon emission lines across redshifts from 0 to 3.5, using an intensity mapping approach. EXCLAIM will broaden our understanding of these elemental and molecular gases and the role they play in star formation processes across cosmic time…
▽ More
The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument that will map carbon monoxide and singly-ionized carbon emission lines across redshifts from 0 to 3.5, using an intensity mapping approach. EXCLAIM will broaden our understanding of these elemental and molecular gases and the role they play in star formation processes across cosmic time scales. The focal plane of EXCLAIM's cryogenic telescope features six μ-Spec spectrometers. μ-Spec is a compact, integrated grating-analog spectrometer, which uses meandered superconducting niobium microstrip transmission lines on a single-crystal silicon dielectric to synthesize the grating. It features superconducting aluminum microwave kinetic inductance detectors (MKIDs), also in a microstrip architecture. The spectrometers for EXCLAIM couple to the telescope optics via a hybrid planar antenna coupled to a silicon lenslet. The spectrometers operate from 420 to 540 GHz with a resolving power R=λ/Δλ=512 and employ an array of 355 MKIDs on each spectrometer. The spectrometer design targets a noise equivalent power (NEP) of 2x10-18W/\sqrt{Hz} (defined at the input to the main lobe of the spectrometer lenslet beam, within a 9-degree half width), enabled by the cryogenic telescope environment, the sensitive MKID detectors, and the low dielectric loss of single-crystal silicon. We report on these spectrometers under development for EXCLAIM, providing an overview of the spectrometer and component designs, the spectrometer fabrication process, fabrication developments since previous prototype demonstrations, and the current status of their development for the EXCLAIM mission.
△ Less
Submitted 27 January, 2021;
originally announced January 2021.
-
Overview and status of EXCLAIM, the experiment for cryogenic large-aperture intensity mapping
Authors:
Giuseppe Cataldo,
Peter Ade,
Christopher Anderson,
Alyssa Barlis,
Emily Barrentine,
Nicholas Bellis,
Alberto Bolatto,
Patrick Breysse,
Berhanu Bulcha,
Jake Connors,
Paul Cursey,
Negar Ehsan,
Thomas Essinger-Hileman,
Jason Glenn,
Joseph Golec,
James Hays-Wehle,
Larry Hess,
Amir Jahromi,
Mark Kimball,
Alan Kogut,
Luke Lowe,
Philip Mauskopf,
Jeffrey McMahon,
Mona Mirzaei,
Harvey Moseley
, et al. (19 additional authors not shown)
Abstract:
The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a balloon-borne far-infrared telescope that will survey star formation history over cosmological time scales to improve our understanding of why the star formation rate declined at redshift z < 2, despite continued clustering of dark matter. Specifically,EXCLAIM will map the emission of redshifted carbon monoxide and singly…
▽ More
The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a balloon-borne far-infrared telescope that will survey star formation history over cosmological time scales to improve our understanding of why the star formation rate declined at redshift z < 2, despite continued clustering of dark matter. Specifically,EXCLAIM will map the emission of redshifted carbon monoxide and singly-ionized carbon lines in windows over a redshift range 0 < z < 3.5, following an innovative approach known as intensity mapping. Intensity mapping measures the statistics of brightness fluctuations of cumulative line emissions instead of detecting individual galaxies, thus enabling a blind, complete census of the emitting gas. To detect this emission unambiguously, EXCLAIM will cross-correlate with a spectroscopic galaxy catalog. The EXCLAIM mission uses a cryogenic design to cool the telescope optics to approximately 1.7 K. The telescope features a 90-cm primary mirror to probe spatial scales on the sky from the linear regime up to shot noise-dominated scales. The telescope optical elements couple to six μ-Spec spectrometer modules, operating over a 420-540 GHz frequency band with a spectral resolution of 512 and featuring microwave kinetic inductance detectors. A Radio Frequency System-on-Chip (RFSoC) reads out the detectors in the baseline design. The cryogenic telescope and the sensitive detectors allow EXCLAIM to reach high sensitivity in spectral windows of low emission in the upper atmosphere. Here, an overview of the mission design and development status since the start of the EXCLAIM project in early 2019 is presented.
△ Less
Submitted 27 January, 2021;
originally announced January 2021.
-
Optical Design of the EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM)
Authors:
Thomas Essinger-Hileman,
Trevor Oxholm,
Gage Siebert,
Peter Ade,
Christopher Anderson,
Alyssa Barlis,
Emily Barrentine,
Jeffrey Beeman,
Nicholas Bellis,
Patrick Breysse,
Alberto Bolatto,
Berhanu Bulcha,
Giuseppe Cataldo,
Jake Connors,
Paul Cursey,
Negar Ehsan,
Lee-Roger Fernandez,
Jason Glenn,
Joseph Golec,
James Hays-Wehle,
Larry Hess,
Amir Jahromi,
Mark Kimball,
Alan Kogut,
Luke Lowe
, et al. (20 additional authors not shown)
Abstract:
This work describes the optical design of the EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM). EXCLAIM is a balloon-borne telescope that will measure integrated line emission from carbon monoxide (CO) at redshifts z < 1 and ionized carbon ([CII]) at redshifts z = 2.5-3.5 to probe star formation over cosmic time in cross-correlation with galaxy redshift surveys. The EXCLAIM inst…
▽ More
This work describes the optical design of the EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM). EXCLAIM is a balloon-borne telescope that will measure integrated line emission from carbon monoxide (CO) at redshifts z < 1 and ionized carbon ([CII]) at redshifts z = 2.5-3.5 to probe star formation over cosmic time in cross-correlation with galaxy redshift surveys. The EXCLAIM instrument will observe at frequencies of 420--540 GHz using six microfabricated silicon integrated spectrometers with spectral resolving power R = 512 coupled to kinetic inductance detectors (KIDs). A completely cryogenic telescope cooled to a temperature below 5 K provides low-background observations between narrow atmospheric lines in the stratosphere. Off-axis reflective optics use a $90$-cm primary mirror to provide 4.2' full-width at half-maximum (FWHM) resolution at the center of the EXCLAIM band over a field of view of 22.5'. Illumination of the 1.7 K cold stop combined with blackened baffling at multiple places in the optical system ensures low (< -40 dB) edge illumination of the primary to minimize spill onto warmer elements at the top of the dewar.
△ Less
Submitted 18 December, 2020;
originally announced December 2020.
-
The Experiment for Cryogenic Large-aperture Intensity Mapping (EXCLAIM)
Authors:
P. A. R. Ade,
C. J. Anderson,
E. M. Barrentine,
N. G. Bellis,
A. D. Bolatto,
P. C. Breysse,
B. T. Bulcha,
G. Cataldo,
J. A. Connors,
P. W. Cursey,
N. Ehsan,
H. C. Grant,
T. M. Essinger-Hileman,
L. A. Hess,
M. O. Kimball,
A. J. Kogut,
A. D. Lamb,
L. N. Lowe,
P. D. Mauskopf,
J. McMahon,
M. Mirzaei,
S. H. Moseley,
J. W. Mugge-Durum,
O. Noroozian,
U. Pen
, et al. (11 additional authors not shown)
Abstract:
The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument that will survey galaxy and star formation history over cosmological time scales. Rather than identifying individual objects, EXCLAIM will be a pathfinder to demonstrate an intensity mapping approach, which measures the cumulative redshifted line emission. EXCLAIM will operate at 420-540…
▽ More
The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument that will survey galaxy and star formation history over cosmological time scales. Rather than identifying individual objects, EXCLAIM will be a pathfinder to demonstrate an intensity mapping approach, which measures the cumulative redshifted line emission. EXCLAIM will operate at 420-540 GHz with a spectral resolution R=512 to measure the integrated CO and [CII] in redshift windows spanning 0 < z < 3.5. CO and [CII] line emissions are key tracers of the gas phases in the interstellar medium involved in star-formation processes. EXCLAIM will shed light on questions such as why the star formation rate declines at z < 2, despite continued clustering of the dark matter. The instrument will employ an array of six superconducting integrated grating-analog spectrometers (micro-spec) coupled to microwave kinetic inductance detectors (MKIDs). Here we present an overview of the EXCLAIM instrument design and status.
△ Less
Submitted 15 December, 2019;
originally announced December 2019.
-
The case for a 'sub-millimeter SDSS': a 3D map of galaxy evolution to z~10
Authors:
James E. Geach,
Manda Banerji,
Frank Bertoldi,
Matthieu Bethermin,
Caitlin M. Casey,
Chian-Chou Chen,
David L. Clements,
Claudia Cicone,
Francoise Combes,
Christopher Conselice,
Asantha Cooray,
Kristen Coppin,
Emanuele Daddi,
Helmut Dannerbauer,
Romeel Dave,
Matthew Doherty,
James S. Dunlop,
Alastair Edge,
Duncan Farrah,
Maximilien Franco,
Gary Fuller,
Tracy Garratt,
Walter Gear,
Thomas R. Greve,
Evanthia Hatziminaoglou
, et al. (31 additional authors not shown)
Abstract:
The Sloan Digital Sky Survey (SDSS) was revolutionary because of the extraordinary breadth and ambition of its optical imaging and spectroscopy. We argue that a 'sub-millimeter SDSS' - a sensitive large-area imaging+spectroscopic survey in the sub-mm window - will revolutionize our understanding of galaxy evolution in the early Universe. By detecting the thermal dust continuum emission and atomic…
▽ More
The Sloan Digital Sky Survey (SDSS) was revolutionary because of the extraordinary breadth and ambition of its optical imaging and spectroscopy. We argue that a 'sub-millimeter SDSS' - a sensitive large-area imaging+spectroscopic survey in the sub-mm window - will revolutionize our understanding of galaxy evolution in the early Universe. By detecting the thermal dust continuum emission and atomic and molecular line emission of galaxies out to z~10 it will be possible to measure the redshifts, star formation rates, dust and gas content of hundreds of thousands of high-z galaxies down to ~L*. Many of these galaxies will have counterparts visible in the deep optical imaging of the Large Synoptic Survey Telescope. This 3D map of galaxy evolution will span the peak epoch of galaxy formation all the way back to cosmic dawn, measuring the co-evolution of the star formation rate density and molecular gas content of galaxies, tracking the production of metals and charting the growth of large-scale structure.
△ Less
Submitted 12 March, 2019;
originally announced March 2019.
-
Peculiar Velocity Constraints from Five-Band SZ Effect Measurements Towards RX J1347.5-1145 with MUSIC and Bolocam from the CSO
Authors:
Jack Sayers,
Michael Zemcov,
Jason Glenn,
Sunil R. Golwala,
Philip R. Maloney,
Seth R. Siegel,
Jordan Wheeler,
Clint Bockstiegel,
Spencer Brugger,
Nicole G. Czakon,
Peter K. Day,
Thomas P. Downes,
Ran P. Duan,
Jiansong Gao,
Matthew I. Hollister,
Albert Lam,
Henry G. LeDuc,
Benjamin A. Mazin,
Sean G. McHugh,
David A. Miller,
Tony K. Mroczkowski,
Omid Noroozian,
Hien T. Nguyen,
Simon J. Radford,
James A. Schlaerth
, et al. (3 additional authors not shown)
Abstract:
We present Sunyaev-Zel'dovich (SZ) effect measurements from wide-field images towards the galaxy cluster RX J1347.5-1145 obtained from the Caltech Submillimeter Observatory with the Multiwavelength Submillimeter Inductance Camera (MUSIC) at 147, 213, 281, and 337 GHz and with Bolocam at 140 GHz. As part of our analysis, we have used higher frequency data from Herschel-SPIRE and previously publishe…
▽ More
We present Sunyaev-Zel'dovich (SZ) effect measurements from wide-field images towards the galaxy cluster RX J1347.5-1145 obtained from the Caltech Submillimeter Observatory with the Multiwavelength Submillimeter Inductance Camera (MUSIC) at 147, 213, 281, and 337 GHz and with Bolocam at 140 GHz. As part of our analysis, we have used higher frequency data from Herschel-SPIRE and previously published lower frequency radio data to subtract the signal from the brightest dusty star-forming galaxies behind RX J1347.5-1145 and from the AGN in RX J1347.5-1145's BCG. Using these five-band SZ effect images, combined with X-ray spectroscopic measurements of the temperature of the intra-cluster medium (ICM) from Chandra, we constrain the ICM optical depth to be $τ_e = 7.33^{+0.96}_{-0.97} \times 10^{-3}$ and the ICM line of sight peculiar velocity to be $v_{pec} = -1040^{+870}_{-840}$ km s$^{-1}$. The errors for both quantities are limited by measurement noise rather than calibration uncertainties or astrophysical contamination, and significant improvements are possible with deeper observations. Our best-fit velocity is in good agreement with one previously published SZ effect analysis and in mild tension with the other, although some or all of that tension may be because that measurement samples a much smaller cluster volume. Furthermore, our best-fit optical depth implies a gas mass slightly larger than the Chandra-derived value, implying the cluster is elongated along the line of sight.
△ Less
Submitted 1 March, 2016; v1 submitted 9 September, 2015;
originally announced September 2015.
-
High-resolution gamma-ray spectroscopy with a microwave-multiplexed transition-edge sensor array
Authors:
Omid Noroozian,
John A. B. Mates,
Douglas A. Bennett,
Justus A. Brevik,
Joseph W. Fowler,
Jiansong Gao,
Gene C. Hilton,
Robert D. Horansky,
Kent D. Irwin,
Zhao Kang,
Daniel R. Schmidt,
Leila R. Vale,
Joel N. Ullom
Abstract:
We demonstrate very high resolution photon spectroscopy with a microwave-multiplexed two-pixel transition-edge sensor (TES) array. We measured a $^{153}$Gd photon source and achieved an energy resolution of 63 eV full-width-at-half-maximum at 97 keV and an equivalent readout system noise of 86 pA/$\sqrt{\text{Hz}}$ at the TES. The readout circuit consists of superconducting microwave resonators co…
▽ More
We demonstrate very high resolution photon spectroscopy with a microwave-multiplexed two-pixel transition-edge sensor (TES) array. We measured a $^{153}$Gd photon source and achieved an energy resolution of 63 eV full-width-at-half-maximum at 97 keV and an equivalent readout system noise of 86 pA/$\sqrt{\text{Hz}}$ at the TES. The readout circuit consists of superconducting microwave resonators coupled to radio-frequency superconducting-quantum-interference-devices (SQUID) and transduces changes in input current to changes in phase of a microwave signal. We use flux-ramp modulation to linearize the response and evade low-frequency noise. This demonstration establishes one path for the readout of cryogenic X-ray and gamma-ray sensor arrays with more than $10^3$ elements and spectral resolving powers $R=λ/Δλ> 10^3$.
△ Less
Submitted 27 October, 2013;
originally announced October 2013.
-
Operation of a titanium nitride superconducting microresonator detector in the nonlinear regime
Authors:
L. J. Swenson,
P. K. Day,
B. H. Eom,
H. G. Leduc,
N. Llombart,
C. M. McKenney,
O. Noroozian,
J. Zmuidzinas
Abstract:
If driven sufficiently strongly, superconducting microresonators exhibit nonlinear behavior including response bifurcation. This behavior can arise from a variety of physical mechanisms including heating effects, grain boundaries or weak links, vortex penetration, or through the intrinsic nonlinearity of the kinetic inductance. Although microresonators used for photon detection are usually driven…
▽ More
If driven sufficiently strongly, superconducting microresonators exhibit nonlinear behavior including response bifurcation. This behavior can arise from a variety of physical mechanisms including heating effects, grain boundaries or weak links, vortex penetration, or through the intrinsic nonlinearity of the kinetic inductance. Although microresonators used for photon detection are usually driven fairly hard in order to optimize their sensitivity, most experiments to date have not explored detector performance beyond the onset of bifurcation. Here we present measurements of a lumped-element superconducting microresonator designed for use as a far-infrared detector and operated deep into the nonlinear regime. The 1 GHz resonator was fabricated from a 22 nm thick titanium nitride film with a critical temperature of 2 K and a normal-state resistivity of $100\, μΩ\,$cm. We measured the response of the device when illuminated with 6.4 pW optical loading using microwave readout powers that ranged from the low-power, linear regime to 18 dB beyond the onset of bifurcation. Over this entire range, the nonlinear behavior is well described by a nonlinear kinetic inductance. The best noise-equivalent power of $2 \times 10^{-16}$ W/Hz$^{1/2}$ at 10 Hz was measured at the highest readout power, and represents a $\sim$10 fold improvement compared with operating below the onset of bifurcation.
△ Less
Submitted 18 May, 2013;
originally announced May 2013.
-
Status of MUSIC, the MUltiwavelength Sub/millimeter Inductance Camera
Authors:
Sunil R. Golwala,
Clint Bockstiegel,
Spencer Brugger,
Nicole G. Czakon,
Peter K. Day,
Thomas P. Downes,
Ran Duan,
Jiansong Gao,
Amandeep K. Gill,
Jason Glenn,
Matthew I. Hollister,
Henry G. LeDuc,
Philip R. Maloney,
Benjamin A. Mazin,
Sean G. McHugh,
David Miller,
Omid Noroozian,
Hien T. Nguyen,
Jack Sayers,
James A. Schlaerth,
Seth Siegel,
Anastasios K. Vayonakis,
Philip R. Wilson,
Jonas Zmuidzinas
Abstract:
We present the status of MUSIC, the MUltiwavelength Sub/millimeter Inductance Camera, a new instrument for the Caltech Submillimeter Observatory. MUSIC is designed to have a 14', diffraction-limited field-of-view instrumented with 2304 detectors in 576 spatial pixels and four spectral bands at 0.87, 1.04, 1.33, and 1.98 mm. MUSIC will be used to study dusty star-forming galaxies, galaxy clusters v…
▽ More
We present the status of MUSIC, the MUltiwavelength Sub/millimeter Inductance Camera, a new instrument for the Caltech Submillimeter Observatory. MUSIC is designed to have a 14', diffraction-limited field-of-view instrumented with 2304 detectors in 576 spatial pixels and four spectral bands at 0.87, 1.04, 1.33, and 1.98 mm. MUSIC will be used to study dusty star-forming galaxies, galaxy clusters via the Sunyaev-Zeldovich effect, and star formation in our own and nearby galaxies. MUSIC uses broadband superconducting phased-array slot-dipole antennas to form beams, lumped-element on-chip bandpass filters to define spectral bands, and microwave kinetic inductance detectors to senseincoming light. The focal plane is fabricated in 8 tiles consisting of 72 spatial pixels each. It is coupled to the telescope via an ambient temperature ellipsoidal mirror and a cold reimaging lens. A cold Lyot stop sits at the image of the primary mirror formed by the ellipsoidal mirror. Dielectric and metal mesh filters are used to block thermal infrared and out-of-band radiation. The instrument uses a pulse tube cooler and 3He/3He/4He closed-cycle cooler to cool the focal plane to below 250 mK. A multilayer shield attenuates Earth's magnetic field. Each focal plane tile is read out by a single pair of coaxes and a HEMT amplifier. The readout system consists of 16 copies of custom-designed ADC/DAC and IF boards coupled to the CASPER ROACH platform. We focus on recent updates on the instrument design and results from the commissioning of the full camera in 2012.
△ Less
Submitted 3 November, 2012;
originally announced November 2012.
-
Crosstalk Reduction for Superconducting Microwave Resonator Arrays
Authors:
Omid Noroozian,
Peter K. Day,
Byeong Ho Eom,
Henry G. Leduc,
Jonas Zmuidzinas
Abstract:
Large-scale arrays of Microwave Kinetic Inductance Detectors (MKIDs) are attractive candidates for use in imaging instruments for next generation submillimeter-wave telescopes such as CCAT. We have designed and fabricated tightly packed ~250-pixel MKID arrays using lumped-element resonators etched from a thin layer of superconducting TiNx deposited on a silicon substrate. The high pixel packing de…
▽ More
Large-scale arrays of Microwave Kinetic Inductance Detectors (MKIDs) are attractive candidates for use in imaging instruments for next generation submillimeter-wave telescopes such as CCAT. We have designed and fabricated tightly packed ~250-pixel MKID arrays using lumped-element resonators etched from a thin layer of superconducting TiNx deposited on a silicon substrate. The high pixel packing density in our initial design resulted in large microwave crosstalk due to electromagnetic coupling between the resonators. Our second design eliminates this problem by adding a grounding shield and using a double-wound geometry for the meander inductor to allow conductors with opposite polarity to be in close proximity. In addition, the resonator frequencies are distributed in a checkerboard pattern across the array. We present details for the two resonator and array designs and describe a circuit model for the full array that predicts the distribution of resonator frequencies and the crosstalk level. We also show results from a new experimental technique that conveniently measures crosstalk without the need for an optical setup. Our results reveal an improvement in crosstalk from 57% in the initial design down to \leq 2% in the second design. The general procedure and design guidelines in this work are applicable to future large arrays employing microwave resonators.
△ Less
Submitted 25 June, 2012;
originally announced June 2012.
-
Titanium Nitride Films for Ultrasensitive Microresonator Detectors
Authors:
Henry G. Leduc,
Bruce Bumble,
Peter K. Day,
Anthony D. Turner,
Byeong Ho Eom,
Sunil Golwala,
David C. Moore,
Omid Noroozian,
Jonas Zmuidzinas,
Jiansong Gao,
Benjamin A. Mazin,
Sean McHugh,
Andrew Merrill
Abstract:
Titanium nitride (TiNx) films are ideal for use in superconducting microresonator detectors because: a) the critical temperature varies with composition (0 < Tc < 5 K); b) the normal-state resistivity is large, ρ_n ~ 100 $μ$Ohm cm, facilitating efficient photon absorption and providing a large kinetic inductance and detector responsivity; and c) TiN films are very hard and mechanically robust. Res…
▽ More
Titanium nitride (TiNx) films are ideal for use in superconducting microresonator detectors because: a) the critical temperature varies with composition (0 < Tc < 5 K); b) the normal-state resistivity is large, ρ_n ~ 100 $μ$Ohm cm, facilitating efficient photon absorption and providing a large kinetic inductance and detector responsivity; and c) TiN films are very hard and mechanically robust. Resonators using reactively sputtered TiN films show remarkably low loss (Q_i > 10^7) and have noise properties similar to resonators made using other materials, while the quasiparticle lifetimes are reasonably long, 10-200 $μ$s. TiN microresonators should therefore reach sensitivities well below 10^-19 WHz^(-1/2).
△ Less
Submitted 9 August, 2010; v1 submitted 29 March, 2010;
originally announced March 2010.
-
Two-level system noise reduction for Microwave Kinetic Inductance Detectors
Authors:
Omid Noroozian,
Jiansong Gao,
Jonas Zmuidzinas,
Henry G. LeDuc,
Benjamin A. Mazin
Abstract:
Noise performance is one of the most crucial aspects of any detector. Superconducting Microwave Kinetic Inductance Detectors (MKIDs) have an "excess" frequency noise that shows up as a small time dependent jitter of the resonance frequency characterized by the frequency noise power spectrum measured in units of Hz^2/Hz. Recent studies have shown that this noise almost certainly originates from a…
▽ More
Noise performance is one of the most crucial aspects of any detector. Superconducting Microwave Kinetic Inductance Detectors (MKIDs) have an "excess" frequency noise that shows up as a small time dependent jitter of the resonance frequency characterized by the frequency noise power spectrum measured in units of Hz^2/Hz. Recent studies have shown that this noise almost certainly originates from a surface layer of two-level system (TLS) defects on the metallization or substrate. Fluctuation of these TLSs introduces noise in the resonator due to coupling of the TLS electric dipole moments to the resonator's electric field. Motivated by a semi-empirical quantitative theory of this noise mechanism, we have designed and tested new resonator geometries in which the high-field "capacitive" portion of the CPW resonator is replaced by an interdigitated capacitor (IDC) structure with 10 - 20 micron electrode spacing, as compared to the 2 micron spacing used for our more conventional CPW resonators. Measurements show that this new IDC design has dramatically lower TLS noise, currently by about a factor of ~29 in terms of the frequency noise power spectrum, corresponding to an improvement of about a factor of 29^(1/2) in NEP. These new devices are replacing the CPW resonators in our next design iteration in progress for MKIDCam. Opportunities and prospects for future reduction of the TLS noise will be discussed.
△ Less
Submitted 10 September, 2009;
originally announced September 2009.