-
Stability of discrete-time Hawkes process with inhibition: towards a general condition
Authors:
Manon Costa,
Pascal Maillard,
Anthony Muraro
Abstract:
In this paper, we study a discrete-time analogue of a Hawkes process, modelled as a Poisson autoregressive process whose parameters depend on the past of the trajectory. The model is characterized to allow these parameters to take negative values, modelling inhibitory dynamics. More precisely, the model is the stochastic process $(\Tilde X_n)_{n\ge0}$ with parameters $a_1,\ldots,a_p \in \R$,…
▽ More
In this paper, we study a discrete-time analogue of a Hawkes process, modelled as a Poisson autoregressive process whose parameters depend on the past of the trajectory. The model is characterized to allow these parameters to take negative values, modelling inhibitory dynamics. More precisely, the model is the stochastic process $(\Tilde X_n)_{n\ge0}$ with parameters $a_1,\ldots,a_p \in \R$, $p\in\N$ and $λ> 0$, such that for all $n\ge p$, conditioned on $\Tilde X_0,\ldots,\Tilde X_{n-1}$, $\Tilde X_n$ is Poisson distributed with parameter \[ \left(a_1 \Tilde X_{n-1} + \cdots + a_p \Tilde X_{n-p} + λ\right)_+. \] This process can be seen as a discrete time Hawkes process with inhibition with a memory of length $p$. %This work is an extension of a prior work where we studied the specific case $p = 2$, for which we were able to classify the asymptotic behaviour of the process for the whole range of parameters, except for boundary cases. We first provide a sufficient condition for stability in the general case which is the analog of a condition for continuous time Hawkes processes from \cite{costa_renewal_2020}. We then focus on the case $p=3$, extending the results derived for the $p=2$ case in a previous work \cite{Costa_Maillard_Muraro_2024}. In particular, we show that the process may be stable even if one of the coefficients $a_i$ is much greater than one.
△ Less
Submitted 3 September, 2024;
originally announced September 2024.
-
(Almost) complete characterization of stability of a discrete-time Hawkes process with inhibition and memory of length two
Authors:
Manon Costa,
Pascal Maillard,
Anthony Muraro
Abstract:
We consider a discrete-time version of a Hawkes process defined as a Poisson auto-regressive process whose parameters depend on the past of the trajectory. We allow these parameters to take on negative values, modelling inhibition. More precisely, the model is the stochastic process $(X_n)_{n\ge0}$ with parameters $a_1,\ldots,a_p \in \mathbb{R}$, $p\in\mathbb{N}$ and $λ\ge 0$, such that for all…
▽ More
We consider a discrete-time version of a Hawkes process defined as a Poisson auto-regressive process whose parameters depend on the past of the trajectory. We allow these parameters to take on negative values, modelling inhibition. More precisely, the model is the stochastic process $(X_n)_{n\ge0}$ with parameters $a_1,\ldots,a_p \in \mathbb{R}$, $p\in\mathbb{N}$ and $λ\ge 0$, such that for all $n\ge p$, conditioned on $X_0,\ldots,X_{n-1}$, $X_n$ is Poisson distributed with parameter \[ \left(a_1 X_{n-1} + \cdots + a_p X_{n-p} + λ\right)_+ \] We consider specifically the case $p = 2$, for which we are able to classify the asymptotic behavior of the process for the whole range of parameters, except for boundary cases. In particular, we show that the process remains stochastically bounded whenever the linear recurrence equation $x_n = a_1x_{n-1} + a_2x_{n-1} + λ$ remains bounded, but the converse is not true. Relatedly, the criterion for stochastic boundedness is not symmetric in $a_1$ and $a_2$, in contrast to the case of non-negative parameters, illustrating the complex effects of inhibition.
△ Less
Submitted 16 February, 2024; v1 submitted 15 May, 2023;
originally announced May 2023.
-
Lessons learned after three years of SPIDER operation and the first MITICA integrated tests
Authors:
D. Marcuzzi,
V. Toigo,
M. Boldrin,
G. Chitarin,
S. Dal Bello,
L. Grando,
A. Luchetta,
R. Pasqualotto,
M. Pavei,
G. Serianni,
L. Zanotto,
R. Agnello,
P. Agostinetti,
M. Agostini,
D. Aprile,
M. Barbisan,
M. Battistella,
G. Berton,
M. Bigi,
M. Brombin,
V. Candela,
V. Candeloro,
A. Canton,
R. Casagrande,
C. Cavallini
, et al. (117 additional authors not shown)
Abstract:
ITER envisages the use of two heating neutral beam injectors plus an optional one as part of the auxiliary heating and current drive system. The 16.5 MW expected neutral beam power per injector is several notches higher than worldwide existing facilities. A Neutral Beam Test Facility (NBTF) was established at Consorzio RFX, exploiting the synergy of two test beds, SPIDER and MITICA. SPIDER is dedi…
▽ More
ITER envisages the use of two heating neutral beam injectors plus an optional one as part of the auxiliary heating and current drive system. The 16.5 MW expected neutral beam power per injector is several notches higher than worldwide existing facilities. A Neutral Beam Test Facility (NBTF) was established at Consorzio RFX, exploiting the synergy of two test beds, SPIDER and MITICA. SPIDER is dedicated to developing and characterizing large efficient negative ion sources at relevant parameters in ITER-like conditions: source and accelerator located in the same vacuum where the beam propagates, immunity to electromagnetic interferences of multiple radio-frequency (RF) antennas, avoidance of RF-induced discharges on the outside of the source. Three years of experiments on SPIDER have addressed to the necessary design modifications to enable full performances. The source is presently under a long shut-down phase to incorporate learnings from the experimental campaign. Parallelly, developments on MITICA, the full-scale prototype of the ITER NBI featuring a 1 MV accelerator and ion neutralization, are underway including manufacturing of in-vessel components, while power supplies and auxiliary plants are already under final testing and commissioning. Integration, commissioning and tests of the 1MV power supplies are essential for this first-of-kind system, unparalleled both in research and industry field. The integrated test to confirm 1MV output by combining invertor systems, DC generators and transmission lines extracted errors/accidents in some components. To realize a concrete system for ITER, solutions for the repair and the improvement of the system were developed. Hence, NBTF is emerging as a necessary facility, due to the large gap with existing injectors, effectively dedicated to identify issues and find solutions to enable successful ITER NBI operations in a time bound fashion.
△ Less
Submitted 4 April, 2023;
originally announced April 2023.
-
Information Theoretic Key Agreement Protocol based on ECG signals
Authors:
Anna V. Guglielmi,
Alberto Muraro,
Giulia Cisotto,
Nicola Laurenti
Abstract:
Wireless body area networks (WBANs) are becoming increasingly popular as they allow individuals to continuously monitor their vitals and physiological parameters remotely from the hospital. With the spread of the SARS-CoV-2 pandemic, the availability of portable pulse-oximeters and wearable heart rate detectors has boomed in the market. At the same time, in 2020 we assisted to an unprecedented inc…
▽ More
Wireless body area networks (WBANs) are becoming increasingly popular as they allow individuals to continuously monitor their vitals and physiological parameters remotely from the hospital. With the spread of the SARS-CoV-2 pandemic, the availability of portable pulse-oximeters and wearable heart rate detectors has boomed in the market. At the same time, in 2020 we assisted to an unprecedented increase of healthcare breaches, revealing the extreme vulnerability of the current generation of WBANs. Therefore, the development of new security protocols to ensure data protection, authentication, integrity and privacy within WBANs are highly needed. Here, we targeted a WBAN collecting ECG signals from different sensor nodes on the individual's body, we extracted the inter-pulse interval (i.e., R-R interval) sequence from each of them, and we developed a new information theoretic key agreement protocol that exploits the inherent randomness of ECG to ensure authentication between sensor pairs within the WBAN. After proper pre-processing, we provide an analytical solution that ensures robust authentication; we provide a unique information reconciliation matrix, which gives good performance for all ECG sensor pairs; and we can show that a relationship between information reconciliation and privacy amplification matrices can be found. Finally, we show the trade-off between the level of security, in terms of key generation rate, and the complexity of the error correction scheme implemented in the system.
△ Less
Submitted 14 May, 2021;
originally announced May 2021.
-
Thermal neutron cross sections of amino acids from average contributions of functional groups
Authors:
G. Romanelli,
D. Onorati,
P. Ulpiani,
S. Cancelli,
E. Perelli-Cippo,
J. I. Márquez Damián,
S. C. Capelli,
G. Croci,
A. Muraro,
M. Tardocchi,
G. Gorini,
C. Andreani,
R. Senesi
Abstract:
The experimental thermal neutron cross sections of the twenty proteinogenic amino acids have been measured over the incident-neutron energy range spanning from 1 meV to 10 keV and data have been interpreted using the multi-phonon expansion based on first-principles calculations. The scattering cross section, dominated by the incoherent inelastic contribution from the hydrogen atoms, can be rationa…
▽ More
The experimental thermal neutron cross sections of the twenty proteinogenic amino acids have been measured over the incident-neutron energy range spanning from 1 meV to 10 keV and data have been interpreted using the multi-phonon expansion based on first-principles calculations. The scattering cross section, dominated by the incoherent inelastic contribution from the hydrogen atoms, can be rationalised in terms of the average contributions of different functional groups, thus neglecting their correlation. These results can be used for modelling the total neutron cross sections of complex organic systems like proteins, muscles, or human tissues from a limited number of starting input functions. This simplification is of crucial importance for fine-tuning of transport simulations used in medical applications, including boron neutron capture therapy as well as secondary neutrons-emission induced during proton therapy. Moreover, the parametrized neutron cross sections allow a better treatment of neutron scattering experiments, providing detailed sample self-attenuation corrections for a variety of biological and soft-matter systems.
△ Less
Submitted 11 February, 2021;
originally announced February 2021.
-
Mechanical Ventilator Milano (MVM): A Novel Mechanical Ventilator Designed for Mass Scale Production in Response to the COVID-19 Pandemic
Authors:
C. Galbiati,
A. Abba,
P. Agnes,
P. Amaudruz,
M. Arba,
F. Ardellier-Desages,
C. Badia,
G. Batignani,
G. Bellani,
G. Bianchi,
D. Bishop,
V. Bocci,
W. Bonivento,
B. Bottino,
M. Bouchard,
S. Brice,
G. Buccino,
S. Bussino,
A. Caminata,
A. Capra,
M. Caravati,
M. Carlini,
L. Carrozzi,
J. M. Cela,
B. Celano
, et al. (123 additional authors not shown)
Abstract:
Presented here is the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for rapid mass production in response to the COVID-19 pandemic to address the urgent shortage of intensive therapy ventilators in many countries, and the growing difficulty in procuring these devices through normal supply chains across borders. This ventilator is an electro-mechanical equ…
▽ More
Presented here is the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for rapid mass production in response to the COVID-19 pandemic to address the urgent shortage of intensive therapy ventilators in many countries, and the growing difficulty in procuring these devices through normal supply chains across borders. This ventilator is an electro-mechanical equivalent of the old and reliable Manley Ventilator, and is able to operate in both pressure-controlled and pressure-supported ventilation modes. MVM is optimized for the COVID-19 emergency, thanks to the collaboration with medical doctors in the front line. MVM is designed for large-scale production in a short amount of time and at a limited cost, as it relays on off-the-shelf components, readily available worldwide. Operation of the MVM requires only a source of compressed oxygen (or compressed medical air) and electrical power. Initial tests of a prototype device with a breathing simulator are also presented. Further tests and developments are underway. At this stage the MVM is not yet a certified medical device but certification is in progress.
△ Less
Submitted 10 April, 2020; v1 submitted 23 March, 2020;
originally announced March 2020.