-
Brain Tumor Segmentation (BraTS) Challenge 2024: Meningioma Radiotherapy Planning Automated Segmentation
Authors:
Dominic LaBella,
Katherine Schumacher,
Michael Mix,
Kevin Leu,
Shan McBurney-Lin,
Pierre Nedelec,
Javier Villanueva-Meyer,
Jonathan Shapey,
Tom Vercauteren,
Kazumi Chia,
Omar Al-Salihi,
Justin Leu,
Lia Halasz,
Yury Velichko,
Chunhao Wang,
John Kirkpatrick,
Scott Floyd,
Zachary J. Reitman,
Trey Mullikin,
Ulas Bagci,
Sean Sachdev,
Jona A. Hattangadi-Gluth,
Tyler Seibert,
Nikdokht Farid,
Connor Puett
, et al. (45 additional authors not shown)
Abstract:
The 2024 Brain Tumor Segmentation Meningioma Radiotherapy (BraTS-MEN-RT) challenge aims to advance automated segmentation algorithms using the largest known multi-institutional dataset of radiotherapy planning brain MRIs with expert-annotated target labels for patients with intact or postoperative meningioma that underwent either conventional external beam radiotherapy or stereotactic radiosurgery…
▽ More
The 2024 Brain Tumor Segmentation Meningioma Radiotherapy (BraTS-MEN-RT) challenge aims to advance automated segmentation algorithms using the largest known multi-institutional dataset of radiotherapy planning brain MRIs with expert-annotated target labels for patients with intact or postoperative meningioma that underwent either conventional external beam radiotherapy or stereotactic radiosurgery. Each case includes a defaced 3D post-contrast T1-weighted radiotherapy planning MRI in its native acquisition space, accompanied by a single-label "target volume" representing the gross tumor volume (GTV) and any at-risk postoperative site. Target volume annotations adhere to established radiotherapy planning protocols, ensuring consistency across cases and institutions. For preoperative meningiomas, the target volume encompasses the entire GTV and associated nodular dural tail, while for postoperative cases, it includes at-risk resection cavity margins as determined by the treating institution. Case annotations were reviewed and approved by expert neuroradiologists and radiation oncologists. Participating teams will develop, containerize, and evaluate automated segmentation models using this comprehensive dataset. Model performance will be assessed using an adapted lesion-wise Dice Similarity Coefficient and the 95% Hausdorff distance. The top-performing teams will be recognized at the Medical Image Computing and Computer Assisted Intervention Conference in October 2024. BraTS-MEN-RT is expected to significantly advance automated radiotherapy planning by enabling precise tumor segmentation and facilitating tailored treatment, ultimately improving patient outcomes.
△ Less
Submitted 15 August, 2024; v1 submitted 28 May, 2024;
originally announced May 2024.
-
A personalized Uncertainty Quantification framework for patient survival models: estimating individual uncertainty of patients with metastatic brain tumors in the absence of ground truth
Authors:
Yuqi Wang,
Aarzu Gupta,
David Carpenter,
Trey Mullikin,
Zachary J. Reitman,
Scott Floyd,
John Kirkpatrick,
Joseph K. Salama,
Paul W. Sperduto,
Jian-Guo Liu,
Mustafa R. Bashir,
Kyle J. Lafata
Abstract:
TodevelopanovelUncertaintyQuantification (UQ) framework to estimate the uncertainty of patient survival models in the absence of ground truth, we developed and evaluated our approach based on a dataset of 1383 patients treated with stereotactic radiosurgery (SRS) for brain metastases between January 2015 and December 2020. Our motivating hypothesis is that a time-to-event prediction of a test pati…
▽ More
TodevelopanovelUncertaintyQuantification (UQ) framework to estimate the uncertainty of patient survival models in the absence of ground truth, we developed and evaluated our approach based on a dataset of 1383 patients treated with stereotactic radiosurgery (SRS) for brain metastases between January 2015 and December 2020. Our motivating hypothesis is that a time-to-event prediction of a test patient on inference is more certain given a higher feature-space-similarity to patients in the training set. Therefore, the uncertainty for a particular patient-of-interest is represented by the concordance index between a patient similarity rank and a prediction similarity rank. Model uncertainty was defined as the increased percentage of the max uncertainty-constrained-AUC compared to the model AUC. We evaluated our method on multiple clinically-relevant endpoints, including time to intracranial progression (ICP), progression-free survival (PFS) after SRS, overall survival (OS), and time to ICP and/or death (ICPD), on a variety of both statistical and non-statistical models, including CoxPH, conditional survival forest (CSF), and neural multi-task linear regression (NMTLR). Our results show that all models had the lowest uncertainty on ICP (2.21%) and the highest uncertainty (17.28%) on ICPD. OS models demonstrated high variation in uncertainty performance, where NMTLR had the lowest uncertainty(1.96%)and CSF had the highest uncertainty (14.29%). In conclusion, our method can estimate the uncertainty of individual patient survival modeling results. As expected, our data empirically demonstrate that as model uncertainty measured via our technique increases, the similarity between a feature-space and its predicted outcome decreases.
△ Less
Submitted 28 November, 2023;
originally announced November 2023.
-
Study of linear energy transfer effect on rib fracture in breast patients receiving pencil-beam-scanning proton therapy
Authors:
Yunze Yang,
Kimberly R. Gergelis,
Jiajian Shen,
Arslan Afzal,
Trey C. Mullikin,
Robert W. Gao,
Khaled Aziz,
Dean A. Shumway,
Kimberly S. Corbin,
Wei Liu,
Robert W. Mutter
Abstract:
Purpose: To study the effect of proton linear energy transfer (LET) on rib fracture in breast cancer patients treated with pencil-beam scanning proton therapy (PBS) using a novel tool of dose-LET volume histogram (DLVH).
Methods: From a prospective registry of patients treated with post-mastectomy proton therapy to the chest wall and regional lymph nodes for breast cancer between 2015 and 2020,…
▽ More
Purpose: To study the effect of proton linear energy transfer (LET) on rib fracture in breast cancer patients treated with pencil-beam scanning proton therapy (PBS) using a novel tool of dose-LET volume histogram (DLVH).
Methods: From a prospective registry of patients treated with post-mastectomy proton therapy to the chest wall and regional lymph nodes for breast cancer between 2015 and 2020, we retrospectively identified rib fracture cases detected after completing treatment. Contemporaneously treated control patients that did not develop rib fracture were matched to patients 2:1 considering prescription dose, boost location, reconstruction status, laterality, chest wall thickness, and treatment year. The DLVH index, V(d, l), defined as volume(V) of the structure with at least dose(d) and LET(l), was calculated. DLVH plots between the fracture and control group were compared. Conditional logistic regression (CLR) model was used to establish the relation of V(d, l) and the observed fracture at each combination of d and l. The p-value derived from CLR model shows the statistical difference between fracture patients and the matched control group. Using the 2D p-value map, the DLVH features associated with the patient outcomes were extracted.
Results: Seven rib fracture patients were identified, and fourteen matched patients were selected for the control group. The median time from the completion of proton therapy to rib fracture diagnosis was 12 months (range 5 to 14 months). Two patients had grade 2 symptomatic rib fracture while the remaining 5 were grade 1 incidentally detected on imaging. The derived p-value map demonstrated larger V(0-36 Gy[RBE], 4.0-5.0 keV/um) in patients experiencing fracture (p<0.1).
Conclusions: In breast cancer patients receiving PBS, a larger volume of chest wall receiving moderate dose and high LET may result in increased risk of rib fracture.
△ Less
Submitted 31 October, 2023;
originally announced October 2023.
-
Quantifying U-Net Uncertainty in Multi-Parametric MRI-based Glioma Segmentation by Spherical Image Projection
Authors:
Zhenyu Yang,
Kyle Lafata,
Eugene Vaios,
Zongsheng Hu,
Trey Mullikin,
Fang-Fang Yin,
Chunhao Wang
Abstract:
The projection of planar MRI data onto a spherical surface is equivalent to a nonlinear image transformation that retains global anatomical information. By incorporating this image transformation process in our proposed spherical projection-based U-Net (SPU-Net) segmentation model design, multiple independent segmentation predictions can be obtained from a single MRI. The final segmentation is the…
▽ More
The projection of planar MRI data onto a spherical surface is equivalent to a nonlinear image transformation that retains global anatomical information. By incorporating this image transformation process in our proposed spherical projection-based U-Net (SPU-Net) segmentation model design, multiple independent segmentation predictions can be obtained from a single MRI. The final segmentation is the average of all available results, and the variation can be visualized as a pixel-wise uncertainty map. An uncertainty score was introduced to evaluate and compare the performance of uncertainty measurements. The proposed SPU-Net model was implemented on the basis of 369 glioma patients with MP-MRI scans (T1, T1-Ce, T2, and FLAIR). Three SPU-Net models were trained to segment enhancing tumor (ET), tumor core (TC), and whole tumor (WT), respectively. The SPU-Net model was compared with (1) the classic U-Net model with test-time augmentation (TTA) and (2) linear scaling-based U-Net (LSU-Net) segmentation models in terms of both segmentation accuracy (Dice coefficient, sensitivity, specificity, and accuracy) and segmentation uncertainty (uncertainty map and uncertainty score). The developed SPU-Net model successfully achieved low uncertainty for correct segmentation predictions (e.g., tumor interior or healthy tissue interior) and high uncertainty for incorrect results (e.g., tumor boundaries). This model could allow the identification of missed tumor targets or segmentation errors in U-Net. Quantitatively, the SPU-Net model achieved the highest uncertainty scores for three segmentation targets (ET/TC/WT): 0.826/0.848/0.936, compared to 0.784/0.643/0.872 using the U-Net with TTA and 0.743/0.702/0.876 with the LSU-Net (scaling factor = 2). The SPU-Net also achieved statistically significantly higher Dice coefficients, underscoring the improved segmentation accuracy.
△ Less
Submitted 12 August, 2023; v1 submitted 12 October, 2022;
originally announced October 2022.