-
The relative Brauer group of $K(1)$-local spectra
Authors:
Itamar Mor
Abstract:
Using profinite Galois descent, we compute the Brauer group of the $K(1)$-local category relative to Morava E-theory. At odd primes this group is generated by a cyclic algebra formed using any primitive $(p-1)$st root of unity, but at the prime two is a group of order $32$ with nontrivial extensions; we give explicit descriptions of the generators, and consider their images in the Brauer group of…
▽ More
Using profinite Galois descent, we compute the Brauer group of the $K(1)$-local category relative to Morava E-theory. At odd primes this group is generated by a cyclic algebra formed using any primitive $(p-1)$st root of unity, but at the prime two is a group of order $32$ with nontrivial extensions; we give explicit descriptions of the generators, and consider their images in the Brauer group of $KO$. Along the way, we compute the relative Brauer group of completed $KO$, using the étale locally trivial Brauer group of Antieau, Meier and Stojanoska.
△ Less
Submitted 1 November, 2023; v1 submitted 11 October, 2023;
originally announced October 2023.
-
Picard and Brauer groups of $K(n)$-local spectra via profinite Galois descent
Authors:
Itamar Mor
Abstract:
Using the proétale site, we construct models for the continuous actions of the Morava stabiliser group on Morava E-theory, its $\infty$-category of $K(n)$-local modules, and its Picard spectrum. For the two sheaves of spectra, we evaluate the resulting descent spectral sequences: these can be thought of as homotopy fixed point spectral sequences for the profinite Galois extension…
▽ More
Using the proétale site, we construct models for the continuous actions of the Morava stabiliser group on Morava E-theory, its $\infty$-category of $K(n)$-local modules, and its Picard spectrum. For the two sheaves of spectra, we evaluate the resulting descent spectral sequences: these can be thought of as homotopy fixed point spectral sequences for the profinite Galois extension $L_{K(n)} \mathbb S \to E_n$. We show that the descent spectral sequence for the Morava E-theory sheaf is the $K(n)$-local $E_n$-Adams spectral sequence. The spectral sequence for the sheaf of Picard spectra is closely related to one recently defined by Heard; our formalism allows us to compare many differentials with those in the $K(n)$-local $E_n$-Adams spectral sequence, and isolate the exotic Picard elements in the $0$-stem. In particular, we show how this recovers the computation due to Hopkins, Mahowald and Sadofsky of the group $\mathrm{Pic}_1$ at all primes. We also use these methods to bound the Brauer group of $K(n)$-local spectra, and compute this bound at height one.
△ Less
Submitted 12 October, 2023; v1 submitted 8 June, 2023;
originally announced June 2023.
-
Optimization and first electronic implementation of the Constant-Fraction Time-Over-Threshold pulse shape discrimination method
Authors:
A. Roy,
D. Vartsky,
I. Mor,
C. Boiano,
S. Brambilla,
S. Riboldi,
E. O. Cohen,
Y. Yehuda-Zada,
A. Beck,
L. Arazi
Abstract:
In this contribution we report on further investigations of the recently-evaluated Constant-Fraction Time-over-Threshold (CF-ToT) method for neutron/gamma-ray pulse shape discrimination (PSD). The superiority of the CF-ToT PSD method over the constant-threshold (CT-ToT) method was previously demonstrated, down to low neutron energy thresholds of 100 keVee. Here, we report on a quantitative compari…
▽ More
In this contribution we report on further investigations of the recently-evaluated Constant-Fraction Time-over-Threshold (CF-ToT) method for neutron/gamma-ray pulse shape discrimination (PSD). The superiority of the CF-ToT PSD method over the constant-threshold (CT-ToT) method was previously demonstrated, down to low neutron energy thresholds of 100 keVee. Here, we report on a quantitative comparison between the traditionally used Charge Comparison (CC) method and the CF-ToT method using a stilbene scintillator coupled to a silicon photomultiplier, implementing an offline analysis of recorded fast-neutron and gamma-ray waveforms. An optimization of the constant fraction value indicates that a 20%-fraction yields the optimum figure-of-merit (FOM) and gamma-ray peak-to-valley (P/V) ratio. The results obtained for a particle energy threshold of 100 keVee show that the FOM and P/V values achieved with the CF-ToT method are superior to those obtained using the standard CC method. In addition, a first electronic implementation of the CF-ToT method was performed using simple circuitry suitable for multichannel architecture. Initial results obtained with this circuit prototype are presented.
△ Less
Submitted 19 December, 2022;
originally announced December 2022.
-
Evaluation of the Constant Fraction Time-Over-Threshold (CF-TOT) method for neutron-gamma pulse shape discrimination
Authors:
A. Roy,
D. Vartsky,
I. Mor,
E. O. Cohen,
Y. Yehuda-Zada,
A. Beck,
L. Arazi
Abstract:
The use of Time-over-Threshold (TOT) for the discrimination between fast neutrons and gamma-rays is advantageous when large number of detection channels are required due to the simplicity of its implementation. However, the results obtained using the standard, Constant Threshold TOT (CT-TOT) are usually inferior to those obtained using other pulse shape discrimination (PSD) methods, such as Charge…
▽ More
The use of Time-over-Threshold (TOT) for the discrimination between fast neutrons and gamma-rays is advantageous when large number of detection channels are required due to the simplicity of its implementation. However, the results obtained using the standard, Constant Threshold TOT (CT-TOT) are usually inferior to those obtained using other pulse shape discrimination (PSD) methods, such as Charge Comparison or Zero-Crossing approaches, especially for low amplitude neutron/gamma-ray pulses. We evaluate another TOT approach for fast neutron/gamma-ray PSD using Constant-Fraction Time-over-Threshold (CF-TOT) pulse shape analysis. The CT-TOT and CF-TOT methods were compared quantitatively using digitized waveforms from a liquid scintillator coupled to a photomultiplier tube as well as from a stilbene scintillator coupled to a photomultiplier tube and a silicon photomultiplier. The quality of CF-TOT neutron/gamma-ray discrimination was evaluated using Receiver Operator Characteristics curves and the results obtained with this approach were compared to the that of the standard CT-TOT method. The CF-TOT PSD method results in > 99.9% rejection of gamma-rays with > 80% neutron acceptance, much better than CT-TOT.
△ Less
Submitted 19 April, 2022; v1 submitted 4 December, 2021;
originally announced December 2021.
-
A method for rapid determination of oil and water content in geological formations
Authors:
D. Vartsky,
M. B. Goldberg,
V. Dangendorf,
I. Israelashvili,
I. Mor,
D. Bar,
K. Tittelmeier,
M. Weierganz,
B. Bromberger,
A. Breskin
Abstract:
A novel method utilizing Fast Neutron Resonance Transmission Radiography is proposed for rapid, non-destructive and quantitative determination of the weight fractions of oil and water in cores taken from subterranean or underwater geological formations. Its ability to distinguish water from oil stems from the unambiguously-specific energy-dependence of the neutron cross-sections for the principal…
▽ More
A novel method utilizing Fast Neutron Resonance Transmission Radiography is proposed for rapid, non-destructive and quantitative determination of the weight fractions of oil and water in cores taken from subterranean or underwater geological formations. Its ability to distinguish water from oil stems from the unambiguously-specific energy-dependence of the neutron cross-sections for the principal elemental constituents. Furthermore, the fluid weight fractions permit determining core porosity and oil and water saturations. In this article we show results of experimental determination of oil and water weight fractions in 10 cm thick samples of Berea Sandstone and Indiana Limestone formations, followed by calculation of their porosity and fluid saturations. The technique may ultimately permit rapid, accurate and non-destructive evaluation of relevant petro-physical properties in thick intact cores. It is suitable for all types of formations including tight shales, clays and oil sands.
△ Less
Submitted 22 June, 2017;
originally announced June 2017.
-
High Spatial-Resolution Fast Neutron Detectors for Imaging and Spectrometry
Authors:
Ilan Mor
Abstract:
Two detection systems based on optical readout were developed:
a. Integrative optical detector A 2nd generation of Time-Resolved Integrative Optical Neutron (TRION) detector was developed. It is based on an integrative optical technique, which permits fast-neutron energy-resolved imaging via time-gated optical readout. This mode of operation allows loss-free operation at very high neutron-flux i…
▽ More
Two detection systems based on optical readout were developed:
a. Integrative optical detector A 2nd generation of Time-Resolved Integrative Optical Neutron (TRION) detector was developed. It is based on an integrative optical technique, which permits fast-neutron energy-resolved imaging via time-gated optical readout. This mode of operation allows loss-free operation at very high neutron-flux intensities. The TRION neutron imaging system can be regarded as a stroboscopic photography of neutrons arriving at the detector on a few-ns time scale. As this spectroscopic capability is based on the Time-of-Flight (TOF) technique, it has to be operated in conjunction with a pulsed neutron source, such as an ion accelerator producing 1-2 ns wide beam pulses at MHz repetition rates. TRION is capable of capturing 4 simultaneous TOF frames within a single accelerator pulse and accumulating them over all pulses contained within a finite acquisition time. The detector principle of operation, simulations and experimental results are described.
b. Fibrous optical detector A fast neutron imaging detector based on micrometric glass capillaries loaded with high- refractive-index liquid scintillator has been developed. Neutron energy spectrometry is based on event-by-event detection and reconstruction of neutron energy from the measurement of the recoil proton track projection length and the amount of light produced in the track. In addition, the detector can provide fast-neutron imaging with position resolution of tens of microns. The detector principle of operation, simulations and experimental results obtained with a small detector prototype are described. Track-imaging of individual recoil protons from incident neutrons in the range of 2-14 MeV are demonstrated as well as preliminary results of detector spectroscopic capabilities.
Keywords: Fast neutron resonance radiography; Time-of-Flight; Fast neutron imaging; Energy-resolved imaging; Neutron spectrometry; Capillary array; Liquid scintillator
△ Less
Submitted 27 April, 2017;
originally announced April 2017.
-
Quantitative discrimination between oil and water in drilled bore cores via fast-neutron resonance transmission radiography
Authors:
D. Vartsky,
M. B. Goldberg,
V. Dangendorf,
I. Israelashvili,
I. Mor,
D. Bar,
K. Tittelmeier,
M. Weierganz,
A. Breskin
Abstract:
A novel method based on Fast Neutron Resonance Transmission Radiography is proposed for non-destructive, quantitative determination of the weight percentages of oil and water in cores taken from subterranean or underwater geological formations. The ability of the method to distinguish water from oil stems from the unambiguously-specific energy dependence of the neutron cross-sections for the princ…
▽ More
A novel method based on Fast Neutron Resonance Transmission Radiography is proposed for non-destructive, quantitative determination of the weight percentages of oil and water in cores taken from subterranean or underwater geological formations. The ability of the method to distinguish water from oil stems from the unambiguously-specific energy dependence of the neutron cross-sections for the principal elemental constituents. Monte-Carlo simulations and initial results of experimental investigations indicate that the technique may provide a rapid, accurate and non-destructive method for quantitative evaluation of core fluids in thick intact cores, including those of tight shales for which the use of conventional core analytical approaches appears to be questionable.
△ Less
Submitted 21 February, 2016;
originally announced February 2016.
-
Time-resolved fast-neutron radiography of air-water two-phase flows in a rectangular channel by an improved detection system
Authors:
Robert Zboray,
Volker Dangendorf,
Ilan Mor,
Benjamin Bromberger,
Kai Tittelmeier
Abstract:
In a previous work we have demonstrated the feasibility of high-frame-rate, fast-neutron radiography of generic air-water two-phase flows in a 1.5 cm thick, rectangular flow channel. The experiments have been carried out at the high-intensity, white-beam facility of the Physikalisch-Technische Bundesanstalt, Germany, using an multi-frame, time-resolved detector developed for fast neutron resonance…
▽ More
In a previous work we have demonstrated the feasibility of high-frame-rate, fast-neutron radiography of generic air-water two-phase flows in a 1.5 cm thick, rectangular flow channel. The experiments have been carried out at the high-intensity, white-beam facility of the Physikalisch-Technische Bundesanstalt, Germany, using an multi-frame, time-resolved detector developed for fast neutron resonance radiography. The results were however not fully optimal and therefore we have decided to modify the detector and optimize it for the given application, which is described in the present work. Furthermore, we managed to improve the image post-processing methodology and the noise suppression. Using the tailored detector and the improved post-processing significant increase in the image quality and an order of magnitude lower exposure times, down to 3.33 ms, have been achieved with minimized motion artifacts. Similar to the previous study, different two-phase flow regimes such as bubbly slug and churn flows have been examined. The enhanced imaging quality enables an improved prediction of two-phase flow parameters like the instantaneous volumetric gas fraction, bubble size and bubble velocities. Instantaneous velocity fields around the gas enclosures can also be more robustly predicted using optical flow methods as previously.
△ Less
Submitted 8 April, 2015;
originally announced April 2015.
-
High-frame rate, fast neutron imaging of two-phase flow in a thin rectangular channel
Authors:
R. Zboray,
I. Mor,
V. Dangendorf,
M. Stark,
K. Tittelmeier,
M. Cortesi,
R. Adams
Abstract:
We have demonstrated the feasibility of performing high-frame-rate, fast neutron radiography of air-water two-phase flows in a thin channel with rectangular cross section. The experiments have been carried out at the accelerator facility of the Physikalisch-Technische Bundesanstalt. A polychromatic, high-intensity fast neutron beam with average energy of 6 MeV was produced by 11.5 MeV deuterons hi…
▽ More
We have demonstrated the feasibility of performing high-frame-rate, fast neutron radiography of air-water two-phase flows in a thin channel with rectangular cross section. The experiments have been carried out at the accelerator facility of the Physikalisch-Technische Bundesanstalt. A polychromatic, high-intensity fast neutron beam with average energy of 6 MeV was produced by 11.5 MeV deuterons hitting a thick Be target. Image sequences down to 10 millisecond exposure times were obtained using a fast-neutron imaging detector developed in the context of fast-neutron resonance imaging. Different two-phase flow regimes such as bubbly slug and churn flows have been examined. Two phase flow parameters like the volumetric gas fraction, bubble size and bubble velocities have been measured. The first results are promising, improvements for future experiments are also discussed.
△ Less
Submitted 8 April, 2015;
originally announced April 2015.
-
Parameters Affecting Temporal Resolution of Time Resolved Integrative Optical Neutron Detector (TRION)
Authors:
I. Mor,
D. Vartsky,
V. Dangendorf,
D. Bar,
G. Feldman,
M. B. Goldberg,
K. Tittelmeier,
B. Bromberger,
M. Brandis,
M. Weierganz
Abstract:
The Time-Resolved Integrative Optical Neutron (TRION) detector was developed for Fast Neutron Resonance Radiography (FNRR), a fast-neutron transmission imaging method that exploits characteristic energy-variations of the total scattering cross-section in the En = 1-10 MeV range to detect specific elements within a radiographed object. As opposed to classical event-counting time of flight (ECTOF),…
▽ More
The Time-Resolved Integrative Optical Neutron (TRION) detector was developed for Fast Neutron Resonance Radiography (FNRR), a fast-neutron transmission imaging method that exploits characteristic energy-variations of the total scattering cross-section in the En = 1-10 MeV range to detect specific elements within a radiographed object. As opposed to classical event-counting time of flight (ECTOF), it integrates the detector signal during a well-defined neutron Time of Flight window corresponding to a pre-selected energy bin, e.g., the energy-interval spanning a cross-section resonance of an element such as C, O and N. The integrative characteristic of the detector permits loss-free operation at very intense, pulsed neutron fluxes, at a cost however, of recorded temporal resolution degradation.
This work presents a theoretical and experimental evaluation of detector related parameters which affect temporal resolution of the TRION system.
△ Less
Submitted 12 November, 2013;
originally announced November 2013.
-
Monte-Carlo Simulations of Radiation-Induced Activation in a Fast-Neutron and Gamma- Based Cargo Inspection System
Authors:
B. Bromberger,
D. Bar,
M. Brandis,
V. Dangendorf,
M. B. Goldberg,
F. Kaufmann,
I. Mor,
R. Nolte,
M. Schmiedel,
K. Tittelmeier,
D. Vartsky,
H. Wershofen
Abstract:
An air cargo inspection system combining two nuclear reaction based techniques, namely Fast-Neutron Resonance Radiography and Dual-Discrete-Energy Gamma Radiography is currently being developed. This system is expected to allow detection of standard and improvised explosives as well as special nuclear materials. An important aspect for the applicability of nuclear techniques in an airport inspecti…
▽ More
An air cargo inspection system combining two nuclear reaction based techniques, namely Fast-Neutron Resonance Radiography and Dual-Discrete-Energy Gamma Radiography is currently being developed. This system is expected to allow detection of standard and improvised explosives as well as special nuclear materials. An important aspect for the applicability of nuclear techniques in an airport inspection facility is the inventory and lifetimes of radioactive isotopes produced by the neutron and gamma radiation inside the cargo, as well as the dose delivered by these isotopes to people in contact with the cargo during and following the interrogation procedure. Using MCNPX and CINDER90 we have calculated the activation levels for several typical inspection scenarios. One example is the activation of various metal samples embedded in a cotton-filled container. To validate the simulation results, a benchmark experiment was performed, in which metal samples were activated by fast-neutrons in a water-filled glass jar. The induced activity was determined by analyzing the gamma spectra. Based on the calculated radioactive inventory in the container, the dose levels due to the induced gamma radiation were calculated at several distances from the container and in relevant time windows after the irradiation, in order to evaluate the radiation exposure of the cargo handling staff, air crew and passengers during flight. The possibility of remanent long-lived radioactive inventory after cargo is delivered to the client is also of concern and was evaluated.
△ Less
Submitted 4 January, 2012;
originally announced January 2012.
-
Proof of principle of a high-spatial-resolution, resonant-response gamma-ray detector for Gamma Resonance Absorption in 14N
Authors:
M. Brandis,
M. B. Goldberg,
D. Vartsky,
E. Friedman,
I. Kreslo,
I. Mardor,
V. Dangendorf,
S. Levi,
I. Mor,
D. Bar
Abstract:
The development of a mm-spatial-resolution, resonant-response detector based on a micrometric glass capillary array filled with liquid scintillator is described. This detector was developed for Gamma Resonance Absorption (GRA) in 14N. GRA is an automatic-decision radiographic screening technique that combines high radiation penetration (the probe is a 9.17 MeV gamma ray) with very good sensitivity…
▽ More
The development of a mm-spatial-resolution, resonant-response detector based on a micrometric glass capillary array filled with liquid scintillator is described. This detector was developed for Gamma Resonance Absorption (GRA) in 14N. GRA is an automatic-decision radiographic screening technique that combines high radiation penetration (the probe is a 9.17 MeV gamma ray) with very good sensitivity and specificity to nitrogenous explosives. Detailed simulation of the detector response to electrons and protons generated by the 9.17 MeV gamma-rays was followed by a proof-of-principle experiment, using a mixed gamma-ray and neutron source. Towards this, a prototype capillary detector was assembled, including the associated filling and readout systems. Simulations and experimental results indeed show that proton tracks are distinguishable from electron tracks at relevant energies, on the basis of a criterion that combines track length and light intensity per unit length.
△ Less
Submitted 16 March, 2011;
originally announced March 2011.
-
Development of an LED reference light source for calibration of radiographic imaging detectors
Authors:
M. Weierganz,
D. Bar,
B. Bromberger,
V. Dangendorf,
G. Feldman,
M. B. Goldberg,
M. Lindemann,
I. Mor,
K. Tittelmeier,
D. Vartsky
Abstract:
A stable reference light source based on an LED (Light Emission Diode) is presented for stabilizing the conversion gain of the opto-electronic system of a gamma- and fast-neutron radiographic and tomographic imaging device. A constant fraction of the LED light is transported to the image plane of the camera and provides a stable reference exposure. This is used to normalize the images during off…
▽ More
A stable reference light source based on an LED (Light Emission Diode) is presented for stabilizing the conversion gain of the opto-electronic system of a gamma- and fast-neutron radiographic and tomographic imaging device. A constant fraction of the LED light is transported to the image plane of the camera and provides a stable reference exposure. This is used to normalize the images during off-line image processing. We have investigated parameters influencing the stability of LEDs and developed procedures and criteria to prepare and select LEDs suitable for delivering stable light outputs for several 100 h of operation.
△ Less
Submitted 8 February, 2010;
originally announced February 2010.
-
A Dual-Purpose Ion-Accelerator for Nuclear-Reaction-Based Explosives-and SNM-Detection in Massive Cargo
Authors:
M. B. Goldberg,
V. Dangendorf,
D. Vartsky,
D. Bar,
R. Böttger,
M. Brandis,
B. Bromberger,
G. Feldman,
E. Friedman,
D. Heflinger,
R. Lauck,
S. Löb,
P. Maier-Komor,
I. Mardor,
I. Mor,
K. -H. Speidel,
K. Tittelmeier,
M. Weierganz
Abstract:
A dual-purpose ion-accelerator concept, capable of serving as radiation source in a versatile, nuclear-reaction-based cargo inspection system, is presented. The system will automatically and reliably detect small, operationally-relevant quantities of concealed explosives and special nuclear materials (SNM). It will be cost-effective, employing largely-common hardware, but different reactions/DAQ…
▽ More
A dual-purpose ion-accelerator concept, capable of serving as radiation source in a versatile, nuclear-reaction-based cargo inspection system, is presented. The system will automatically and reliably detect small, operationally-relevant quantities of concealed explosives and special nuclear materials (SNM). It will be cost-effective, employing largely-common hardware, but different reactions/DAQ-modes. Typical expected throughput is 10-20 aviation containers/hr.
PACS: 25.20.Dc; 25.40.Ny; 27.20.+n; 29.27.Fh; 79.77.+g; 89.20.Bb; 89.20.Dd
Keywords: Cargo inspection; Nuclear-reaction-based methods; Explosives detection; SNM detection
△ Less
Submitted 19 January, 2010;
originally announced January 2010.
-
High Spatial Resolution Fast-Neutron Imaging Detectors for Pulsed Fast-Neutron Transmission Spectroscopy
Authors:
I. Mor,
D. Vartsky,
D. Bar,
G. Feldman,
M. B. Goldberg,
D. Katz,
E. Sayag,
I. Shmueli,
Y. Cohen,
A. Tal,
Z. Vagish,
B. Bromberger,
V. Dangendorf,
D. Mugai,
K. Tittelmeier,
M. Weierganz
Abstract:
Two generations of a novel detector for high-resolution transmission imaging and spectrometry of fast-neutrons are presented. These devices are based on a hydrogenous fiber scintillator screen and single- or multiple-gated intensified camera systems (ICCD). This detector is designed for energy-selective neutron radiography with nanosecond-pulsed broad-energy (1 - 10 MeV) neutron beams. Utilizing…
▽ More
Two generations of a novel detector for high-resolution transmission imaging and spectrometry of fast-neutrons are presented. These devices are based on a hydrogenous fiber scintillator screen and single- or multiple-gated intensified camera systems (ICCD). This detector is designed for energy-selective neutron radiography with nanosecond-pulsed broad-energy (1 - 10 MeV) neutron beams. Utilizing the Time-of-Flight (TOF) method, such a detector is capable of simultaneously capturing several images, each at a different neutron energy (TOF). In addition, a gamma-ray image can also be simultaneously registered, allowing combined neutron/gamma inspection of objects. This permits combining the sensitivity of the fast-neutron resonance method to low-Z elements with that of gamma radiography to high-Z materials.
△ Less
Submitted 27 May, 2009;
originally announced May 2009.
-
Low-Afterglow, High-Refractive-Index Liquid Scintillators for Fast-Neutron Spectrometry and Imaging Applications
Authors:
Ronald Lauck,
Michal Brandis,
Benjamin Bromberger,
Volker Dangendorf,
Mark B. Goldberg,
Ilan Mor,
Kai Tittelmeier,
David Vartsky
Abstract:
For ion and neutron spectrometry and imaging applications at a high intensity pulsed laser facility, fast liquid scintillators with very low afterglow are required. Furthermore, neutron imaging with fiber (or liquid-core) capillary arrays calls for scintillation materials with high refractive index. To this end, we have examined various combinations of established mixtures of fluors and solvents…
▽ More
For ion and neutron spectrometry and imaging applications at a high intensity pulsed laser facility, fast liquid scintillators with very low afterglow are required. Furthermore, neutron imaging with fiber (or liquid-core) capillary arrays calls for scintillation materials with high refractive index. To this end, we have examined various combinations of established mixtures of fluors and solvents, that were enriched alternatively with nitrogen or oxygen. Dissolved molecular oxygen is known to be a highly effective quenching agent, that efficiently suppresses the population of the triplet states in the fluor, which are primarily responsible for the afterglow. For measuring the glow curves of scintillators, we have employed the time-correlated single photon counting (TCSPC) technique, characterized by high dynamic range of several orders of magnitude in light intensity. In this paper we outline the application for the fast scintillators, briefly present the scintillation mechanism in liquids, describe our specific TCSPC method and discuss the results.
△ Less
Submitted 25 May, 2009;
originally announced May 2009.
-
Multi-Frame Energy-Selective Imaging System for Fast-Neutron Radiography
Authors:
Volker Dangendorf,
Doron Bar,
Benjamin Bromberger,
Gennady Feldman,
Mark B. Goldberg,
Ronald Lauck,
Ilan Mor,
Kai Tittelmeier,
David Vartsky,
Mathias Weierganz
Abstract:
A new instrument for high resolution imaging of fast-neutrons is presented here. It is designed for energy selective radiography in nanosecond-pulsed broad-energy (1 - 10 MeV) neutron beams. The device presented here is based on hydrogenous scintillator screens and single- or multiple-gated intensified camera systems (ICCD). A key element is a newly developed optical amplifier which generates su…
▽ More
A new instrument for high resolution imaging of fast-neutrons is presented here. It is designed for energy selective radiography in nanosecond-pulsed broad-energy (1 - 10 MeV) neutron beams. The device presented here is based on hydrogenous scintillator screens and single- or multiple-gated intensified camera systems (ICCD). A key element is a newly developed optical amplifier which generates sufficient light for the high-speed intensified camera system, even from such faint light sources as fast plastic and liquid scintillators. Utilizing the Time-of-Flight (TOF) method, the detector incorporating the above components is capable of simultaneously taking up to 8 images, each at a different neutron energy.
△ Less
Submitted 25 May, 2009;
originally announced May 2009.
-
Signal and Noise Analysis in TRION -Time-Resolved Integrative Optical Fast Neutron Detector
Authors:
D. Vartsky,
G. Feldman,
I. Mor,
M. B. Goldberg,
D. Bar,
V. Dangendorf
Abstract:
TRION is a sub-mm spatial resolution fast neutron imaging detector, which employs an integrative optical time-of-flight technique. The detector was developed for fast neutron resonance radiography, a method capable of detecting a broad range of conventional and improvised explosives. In this study we have analyzed in detail, using Monte-Carlo calculations and experimentally determined parameters…
▽ More
TRION is a sub-mm spatial resolution fast neutron imaging detector, which employs an integrative optical time-of-flight technique. The detector was developed for fast neutron resonance radiography, a method capable of detecting a broad range of conventional and improvised explosives. In this study we have analyzed in detail, using Monte-Carlo calculations and experimentally determined parameters, all the processes that influence the signal and noise in the TRION detector. In contrast to event-counting detectors where the signal-to-noise ratio is dependent only on the number of detected events (quantum noise), in an energy-integrating detector additional factors, such as the fluctuations in imparted energy, number of photoelectrons, system gain and other factors will contribute to the noise. The excess noise factor (over the quantum noise) due to these processes was 4.3, 2.7, 2.1, 1.9 and 1.9 for incident neutron energies of 2, 4, 7.5, 10 and 14 MeV, respectively. It is shown that, even under ideal light collection conditions, a fast neutron detection system operating in an integrative mode cannot be quantum-noise-limited due to the relatively large variance in the imparted proton energy and the resulting scintillation light distributions.
△ Less
Submitted 24 December, 2008;
originally announced December 2008.
-
Time-resolved fast neutron imaging: simulation of detector performance
Authors:
D. Vartsky,
I. Mor,
M. B. Goldberg,
I. Mardor,
G. Feldman,
D. Bar,
A. Shor,
V. Dangendorf,
G. Laczko,
A. Breskin,
R. Chechik
Abstract:
We have analyzed and compared the performance of two novel fast-neutron imaging methods with time-of-flight spectroscopy capability. Using MCNP and GEANT code simulations of neutron and charged-particle transport in the detectors, key parameters such as detection efficiency, the amount of energy deposited in the converter and the spatial resolution of both detector variants have been evaluated.
We have analyzed and compared the performance of two novel fast-neutron imaging methods with time-of-flight spectroscopy capability. Using MCNP and GEANT code simulations of neutron and charged-particle transport in the detectors, key parameters such as detection efficiency, the amount of energy deposited in the converter and the spatial resolution of both detector variants have been evaluated.
△ Less
Submitted 17 August, 2004;
originally announced August 2004.
-
Detectors for Time-of-Flight Fast-Neutron Radiography: 1. Neutron Counting Gas Detector
Authors:
V. Dangendorf,
A. Breskin,
R. Chechik,
M. Goldberg,
G. Laczko,
I. Mor,
M. Reginatto,
D. Vartsky
Abstract:
One of our two methods for fast-neutron imaging with spectrometric capability is presented here. It is a neutron-counting technique based on a hydrogenous neutron converter coupled to Gaseous Electron Multipliers (GEM). The principles of the detection techniques and the optimization of the converter, electron amplification and the readout are described. Evaluation of the properties are derived f…
▽ More
One of our two methods for fast-neutron imaging with spectrometric capability is presented here. It is a neutron-counting technique based on a hydrogenous neutron converter coupled to Gaseous Electron Multipliers (GEM). The principles of the detection techniques and the optimization of the converter, electron amplification and the readout are described. Evaluation of the properties are derived from a experiment in a pulsed neutron beam of spectral distribution between 2 and 10 MeV
△ Less
Submitted 17 August, 2004;
originally announced August 2004.
-
Detectors for Energy-Resolved Fast Neutron Imaging
Authors:
V. Dangendorf,
A. Breskin,
R. Chechik,
G. Feldman,
M. B. Goldberg,
O. Jagutzki,
C. Kersten,
G. Laczko,
I. Mor,
U. Spillman,
D. Vartsky
Abstract:
Two detectors for energy-resolved fast-neutron imaging in pulsed broad-energy neutron beams are presented. The first one is a neutron-counting detector based on a solid neutron converter coupled to a gaseous electron multiplier (GEM). The second is an integrating imaging technique, based on a scintillator for neutron conversion and an optical imaging system with fast framing capability.
Two detectors for energy-resolved fast-neutron imaging in pulsed broad-energy neutron beams are presented. The first one is a neutron-counting detector based on a solid neutron converter coupled to a gaseous electron multiplier (GEM). The second is an integrating imaging technique, based on a scintillator for neutron conversion and an optical imaging system with fast framing capability.
△ Less
Submitted 25 March, 2004;
originally announced March 2004.