Influence of optical aberrations on the accuracy of an atomic gravimeter
Authors:
Louis Pagot,
Sébastien Merlet,
Franck Pereira dos Santos
Abstract:
We present numerical simulations of the impact of laser beam wavefront aberrations in cold atom interferometers. We demonstrate that to reach accuracy at the mrad level, simulations cannot be based on a description of the retroreflection optics only with low-order Zernike polynomials, as the results will then depend on the decomposition order and the decomposition technique chosen. Moreover, simul…
▽ More
We present numerical simulations of the impact of laser beam wavefront aberrations in cold atom interferometers. We demonstrate that to reach accuracy at the mrad level, simulations cannot be based on a description of the retroreflection optics only with low-order Zernike polynomials, as the results will then depend on the decomposition order and the decomposition technique chosen. Moreover, simulations with high-order Zernike polynomials or equivalently high spatial frequency components require the propagation of aberrations to be taken into account, rather than adding them to the ideally propagated beam. Finally, we examine the impact of the parameters of the atomic source and show that the use of delta-kicked atomic cloud would efficiently mitigate the impact of this systematic effect.
△ Less
Submitted 10 October, 2024;
originally announced October 2024.
-
Separating the output ports of a Bragg interferometer via velocity selective transport
Authors:
Raphaël Piccon,
Sumit Sarkar,
Sébastien Merlet,
Franck Pereira dos Santos
Abstract:
We report on the study of a detection scheme based on a Bloch separator in two-photon Bragg interferometers. We increase the spatial separation between the two output ports of the interferometer by selectively imparting 30 Bloch oscillations to one of them before their detection via time of flight. This method allows increasing the duration of the interferometer by reducing the time for discrimina…
▽ More
We report on the study of a detection scheme based on a Bloch separator in two-photon Bragg interferometers. We increase the spatial separation between the two output ports of the interferometer by selectively imparting 30 Bloch oscillations to one of them before their detection via time of flight. This method allows increasing the duration of the interferometer by reducing the time for discriminating the ports of the interferometer at detection. We study in detail the impact of this separator on the performance of a dual gravity sensor, and in particular on its measurement sensitivities to gravity acceleration and gravity gradients.
△ Less
Submitted 7 March, 2022;
originally announced March 2022.
-
A compact differential gravimeter at the quantum projection noise limit
Authors:
Camille Janvier,
Vincent Ménoret,
Sébastien Merlet,
Arnaud Landragin,
Franck Pereira Dos Santos,
Bruno Desruelle
Abstract:
Atom interferometry offers new perspectives for geophysics and inertial sensing. We present the industrial prototype of a new type of quantum-based instrument: a compact, transportable, differential quantum gravimeter capable of measuring simultaneously the absolute values of both gravitational acceleration, $g$, and its vertical gradient, $Γ_{zz}$. While the sensitivity to g is competitive with t…
▽ More
Atom interferometry offers new perspectives for geophysics and inertial sensing. We present the industrial prototype of a new type of quantum-based instrument: a compact, transportable, differential quantum gravimeter capable of measuring simultaneously the absolute values of both gravitational acceleration, $g$, and its vertical gradient, $Γ_{zz}$. While the sensitivity to g is competitive with the best industrial gravimeters, the sensitivity on $Γ_{zz}$ reaches the limit set by quantum projection noise-leading to an unprecedented long-term stability of 0.1 E ($1E=1\times 10^{-9}s^{-2}$). This unique, dual-purpose instrument, paves the way for new applications in geophysics, civil engineering, and gravity-aided navigation, where accurate mapping of the gravitational field plays an important role.
△ Less
Submitted 10 January, 2022;
originally announced January 2022.
-
Calibration of a superconducting gravimeter with an absolute atom gravimeter
Authors:
S. Merlet,
P. Gillot,
B. Cheng,
R. Karcher,
A. Imanaliev,
L. Timmen,
F. Pereira Dos Santos
Abstract:
We present a 27-days long common view measurement of an absolute cold atom gravimeter (CAG) and a relative iGrav superconducting gravimeter, which we use to calibrate the iGrav scale factor. This allowed us to push the CAG long-term stability down to the level of 0.5~nm.s$^{-2}$. We investigate the impact of the duration of the measurement on the uncertainty in the determination of the correlation…
▽ More
We present a 27-days long common view measurement of an absolute cold atom gravimeter (CAG) and a relative iGrav superconducting gravimeter, which we use to calibrate the iGrav scale factor. This allowed us to push the CAG long-term stability down to the level of 0.5~nm.s$^{-2}$. We investigate the impact of the duration of the measurement on the uncertainty in the determination of the correlation factor and show that it is limited to about 3\textperthousand~by the coloured noise of our cold atom gravimeter. A 3-days long measurement session with an additional FG5X absolute gravimeter allows us to directly compare the calibration results obtained with two different absolute meters. Based on our analysis, we expect that with an improvement of its long term stability, the CAG will allow to calibrate the iGrav scale factor to better than the per mille level (1$σ$ level of confidence) after only one-day of concurrent measurements for maximum tidal amplitudes.
△ Less
Submitted 15 February, 2021; v1 submitted 20 July, 2020;
originally announced July 2020.
-
Technologies for the ELGAR large scale atom interferometer array
Authors:
B. Canuel,
S. Abend,
P. Amaro-Seoane,
F. Badaracco,
Q. Beaufils,
A. Bertoldi,
K. Bongs,
P. Bouyer,
C. Braxmaier,
W. Chaibi,
N. Christensen,
F. Fitzek,
G. Flouris,
N. Gaaloul,
S. Gaffet,
C. L. Garrido Alzar,
R. Geiger,
S. Guellati-Khelifa,
K. Hammerer,
J. Harms,
J. Hinderer,
M. Holynski,
J. Junca,
S. Katsanevas,
C. Klempt
, et al. (34 additional authors not shown)
Abstract:
We proposed the European Laboratory for Gravitation and Atom-interferometric Research (ELGAR), an array of atom gradiometers aimed at studying space-time and gravitation with the primary goal of observing gravitational waves (GWs) in the infrasound band with a peak strain sensitivity of $3.3 \times 10^{-22}/\sqrt{\text{Hz}}$ at 1.7 Hz. In this paper we detail the main technological bricks of this…
▽ More
We proposed the European Laboratory for Gravitation and Atom-interferometric Research (ELGAR), an array of atom gradiometers aimed at studying space-time and gravitation with the primary goal of observing gravitational waves (GWs) in the infrasound band with a peak strain sensitivity of $3.3 \times 10^{-22}/\sqrt{\text{Hz}}$ at 1.7 Hz. In this paper we detail the main technological bricks of this large scale detector and emphasis the research pathways to be conducted for its realization. We discuss the site options, atom optics, and source requirements needed to reach the target sensitivity. We then discuss required seismic isolation techniques, Gravity Gradient Noise reduction strategies, and the metrology of various noise couplings to the detector.
△ Less
Submitted 8 July, 2020;
originally announced July 2020.
-
High-accuracy inertial measurements with cold-atom sensors
Authors:
Remi Geiger,
Arnaud Landragin,
Sébastien Merlet,
Franck Pereira Dos Santos
Abstract:
The research on cold-atom interferometers gathers a large community of about 50 groups worldwide both in the academic and now in the industrial sectors. The interest in this sub-field of quantum sensing and metrology lies in the large panel of possible applications of cold-atom sensors for measuring inertial and gravitational signals with a high level of stability and accuracy. This review present…
▽ More
The research on cold-atom interferometers gathers a large community of about 50 groups worldwide both in the academic and now in the industrial sectors. The interest in this sub-field of quantum sensing and metrology lies in the large panel of possible applications of cold-atom sensors for measuring inertial and gravitational signals with a high level of stability and accuracy. This review presents the evolution of the field over the last 30 years and focuses on the acceleration of the research effort in the last 10 years. The article describes the physics principle of cold-atom gravito-inertial sensors as well as the main parts of hardware and the expertise required when starting the design of such sensors. It then reviews the progress in the development of instruments measuring gravitational and inertial signals, with a highlight on the limitations to the performances of the sensors, on their applications, and on the latest directions of research.
△ Less
Submitted 27 March, 2020;
originally announced March 2020.
-
Impact of direct digital synthesizer finite resolution on atom gravimeters
Authors:
R Karcher,
Franck Pereira dos Santos,
S Merlet
Abstract:
We report on the study of the impact of the finite resolution of the chirp rate applied on the frequency difference between the Raman lasers beamsplitters onto the phase of a free fall atom gravimeter. This chirp induces a phase shift that compensates the one due to gravity acceleration, allowing for its precise determination in terms of frequencies. In practice, it is most often generated by a di…
▽ More
We report on the study of the impact of the finite resolution of the chirp rate applied on the frequency difference between the Raman lasers beamsplitters onto the phase of a free fall atom gravimeter. This chirp induces a phase shift that compensates the one due to gravity acceleration, allowing for its precise determination in terms of frequencies. In practice, it is most often generated by a direct digital synthesizer (DDS). Besides the effect of eventual truncation errors, we evaluate here the bias on the g measurement due to the finite time and frequency resolution of the chirp generated by the DDS, and show that it can compromise the measurement accuracy. However, this effect can be mitigated by an adequate choice of the DDS chirp parameters resulting from a trade-off between interferometer phase resolution and induced bias.
△ Less
Submitted 21 January, 2020;
originally announced January 2020.
-
ELGAR -- a European Laboratory for Gravitation and Atom-interferometric Research
Authors:
B. Canuel,
S. Abend,
P. Amaro-Seoane,
F. Badaracco,
Q. Beaufils,
A. Bertoldi,
K. Bongs,
P. Bouyer,
C. Braxmaier,
W. Chaibi,
N. Christensen,
F. Fitzek,
G. Flouris,
N. Gaaloul,
S. Gaffet,
C. L. Garrido Alzar,
R. Geiger,
S. Guellati-Khelifa,
K. Hammerer,
J. Harms,
J. Hinderer,
J. Junca,
S. Katsanevas,
C. Klempt,
C. Kozanitis
, et al. (33 additional authors not shown)
Abstract:
Gravitational Waves (GWs) were observed for the first time in 2015, one century after Einstein predicted their existence. There is now growing interest to extend the detection bandwidth to low frequency. The scientific potential of multi-frequency GW astronomy is enormous as it would enable to obtain a more complete picture of cosmic events and mechanisms. This is a unique and entirely new opportu…
▽ More
Gravitational Waves (GWs) were observed for the first time in 2015, one century after Einstein predicted their existence. There is now growing interest to extend the detection bandwidth to low frequency. The scientific potential of multi-frequency GW astronomy is enormous as it would enable to obtain a more complete picture of cosmic events and mechanisms. This is a unique and entirely new opportunity for the future of astronomy, the success of which depends upon the decisions being made on existing and new infrastructures. The prospect of combining observations from the future space-based instrument LISA together with third generation ground based detectors will open the way towards multi-band GW astronomy, but will leave the infrasound (0.1 Hz to 10 Hz) band uncovered. GW detectors based on matter wave interferometry promise to fill such a sensitivity gap. We propose the European Laboratory for Gravitation and Atom-interferometric Research (ELGAR), an underground infrastructure based on the latest progress in atomic physics, to study space-time and gravitation with the primary goal of detecting GWs in the infrasound band. ELGAR will directly inherit from large research facilities now being built in Europe for the study of large scale atom interferometry and will drive new pan-European synergies from top research centers developing quantum sensors. ELGAR will measure GW radiation in the infrasound band with a peak strain sensitivity of $4.1 \times 10^{-22}/\sqrt{\text{Hz}}$ at 1.7 Hz. The antenna will have an impact on diverse fundamental and applied research fields beyond GW astronomy, including gravitation, general relativity, and geology.
△ Less
Submitted 9 November, 2019;
originally announced November 2019.
-
A prototype industrial laser system for cold atom inertial sensing in space
Authors:
Romain Caldani,
Sébastien Merlet,
Franck Pereira Dos Santos,
Guillaume Stern,
Anne-Sophie Martin,
Bruno Desruelle,
Vincent Ménoret
Abstract:
We present the design, realization, characterization and testing of an industrial prototype of a laser system, which is based on frequency doubling of telecom lasers and features all key functionalities to drive a cold atom space gradiometer based on the architecture proposed in [Trimeche et al, 2019]. Testing was performed by implementing the laser system onto a ground based atomic sensor current…
▽ More
We present the design, realization, characterization and testing of an industrial prototype of a laser system, which is based on frequency doubling of telecom lasers and features all key functionalities to drive a cold atom space gradiometer based on the architecture proposed in [Trimeche et al, 2019]. Testing was performed by implementing the laser system onto a ground based atomic sensor currently under development. The system reaches a Technology Readiness Level (TRL) of 4, corresponding to an operational validation in a controlled environment. The optical architecture of the system can be adapted to other space mission scenarios.
△ Less
Submitted 27 August, 2019;
originally announced August 2019.
-
Simultaneous accurate determination of both gravity and its vertical gradient
Authors:
R. Caldani,
K Weng,
S. Merlet,
Franck Pereira dos Santos
Abstract:
We present a method for the accurate measurements of both the gravity acceleration and its vertical gradient using a dual atom interferometer, in principle free from any uncertainty related to the absolute or relative positions of the two atomic samples. The method relies on the use of a dual lock technique, which stirs simultaneously the chirp rate applied to the frequency difference between the…
▽ More
We present a method for the accurate measurements of both the gravity acceleration and its vertical gradient using a dual atom interferometer, in principle free from any uncertainty related to the absolute or relative positions of the two atomic samples. The method relies on the use of a dual lock technique, which stirs simultaneously the chirp rate applied to the frequency difference between the interferometer lasers to compensate the gravity acceleration, and the frequency jump applied to the lasers at the mid pulse of the interferometer to compensate for the gravity gradient. This allows in the end to determine the two inertial quantities of interest in terms of frequencies.
△ Less
Submitted 21 December, 2018;
originally announced December 2018.
-
Improving the accuracy of atom interferometers with ultracold sources
Authors:
R Karcher,
A Imanaliev,
S. Merlet,
Franck Pereira dos Santos
Abstract:
We report on the implementation of ultracold atoms as a source in a state of the art atom gravimeter. We perform gravity measurements with 10 nm/s 2 statistical uncertainties in a so-far unexplored temperature range for such a high accuracy sensor, down to 50 nK. This allows for an improved characterization of the most limiting systematic effect, related to wavefront aberrations of light beam spli…
▽ More
We report on the implementation of ultracold atoms as a source in a state of the art atom gravimeter. We perform gravity measurements with 10 nm/s 2 statistical uncertainties in a so-far unexplored temperature range for such a high accuracy sensor, down to 50 nK. This allows for an improved characterization of the most limiting systematic effect, related to wavefront aberrations of light beam splitters. A thorough model of the impact of this effect onto the measurement is developed and a method is proposed to correct for this bias based on the extrapolation of the measurements down to zero temperature. Finally, an uncertainty of 13 nm/s 2 is obtained in the evaluation of this systematic effect, which can be improved further by performing measurements at even lower temperatures. Our results clearly demonstrate the benefit brought by ultracold atoms to the metrological study of free falling atom interferometers. By tackling their main limitation, our method allows reaching record-breaking accuracies for inertial sensors based on atom interferometry.
△ Less
Submitted 13 April, 2018;
originally announced April 2018.
-
Differential phase extraction in dual interferometers exploiting the correlation between classical and quantum sensors
Authors:
M. Langlois,
R. Caldani,
A. Trimeche,
S. Merlet,
Franck Pereira dos Santos
Abstract:
We perform the experimental demonstration of the method proposed in [Phys. Rev. A 91, 063615 (2015)] to extract the differential phase in dual atom interferometers. From a single magneto-optical trap, we generate two atomic sources, vertically separated and free-falling synchronously, with the help of an accelerated lattice. We drive simultaneous Raman interferometers onto the two sources, and use…
▽ More
We perform the experimental demonstration of the method proposed in [Phys. Rev. A 91, 063615 (2015)] to extract the differential phase in dual atom interferometers. From a single magneto-optical trap, we generate two atomic sources, vertically separated and free-falling synchronously, with the help of an accelerated lattice. We drive simultaneous Raman interferometers onto the two sources, and use the correlation with the vibration signal measured by a seismometer to extract the phase of each interferometer. We demonstrate an optimal sensitivity of the extracted differential phase between the two interferometers, free from vibration noise and limited by detection noise, when the two interferometers are in phase.
△ Less
Submitted 6 December, 2017;
originally announced December 2017.
-
Active Control of Laser Wavefronts in Atom Interferometers
Authors:
Azer Trimeche,
Mehdi Langlois,
Sébastien Merlet,
Franck Pereira dos Santos
Abstract:
Wavefront aberrations are identified as a major limitation in quantum sensors. They are today the main contribution in the uncertainty budget of best cold atom interferometers based on two-photon laser beam splitters, and constitute an important limit for their long-term stability, impeding these instruments from reaching their full potential. Moreover, they will also remain a major obstacle in fu…
▽ More
Wavefront aberrations are identified as a major limitation in quantum sensors. They are today the main contribution in the uncertainty budget of best cold atom interferometers based on two-photon laser beam splitters, and constitute an important limit for their long-term stability, impeding these instruments from reaching their full potential. Moreover, they will also remain a major obstacle in future experiments based on large momentum beam splitters. In this article, we tackle this issue by using a deformable mirror to control actively the laser wavefronts in atom interferometry. In particular, we demonstrate in an experimental proof of principle the efficient correction of wavefront aberrations in an atomic gravimeter.
△ Less
Submitted 24 April, 2017;
originally announced April 2017.
-
Coherent population trapping in a Raman atom interferometer
Authors:
Bing Cheng,
Pierre Gillot,
Sébastien Merlet,
Franck Pereira dos Santos
Abstract:
We investigate the effect of coherent population trapping (CPT) in an atom inter-ferometer gravimeter based on the use of stimulated Raman transitions. We find that CPT leads to significant phase shifts, of order of a few mrad, which may compromise the accuracy of inertial measurements. We show that this effect is rejected by the k-reversal technique, which consists in averaging inertial measureme…
▽ More
We investigate the effect of coherent population trapping (CPT) in an atom inter-ferometer gravimeter based on the use of stimulated Raman transitions. We find that CPT leads to significant phase shifts, of order of a few mrad, which may compromise the accuracy of inertial measurements. We show that this effect is rejected by the k-reversal technique, which consists in averaging inertial measurements performed with two opposite orientations of the Raman wavevector k, provided that internal states at the input of the interferometer are kept identical for both configurations.
△ Less
Submitted 9 June, 2016;
originally announced June 2016.
-
Metrology with Atom Interferometry: Inertial Sensors from Laboratory to Field Applications
Authors:
Bess Fang,
Indranil Dutta,
Pierre Gillot,
Denis Savoie,
Jean Lautier,
Bing Cheng,
Carlos L Garrido Alzar,
Remi Geiger,
Sebastien Merlet,
Franck Pereira Dos Santos,
Arnaud Landragin
Abstract:
Developments in atom interferometry have led to atomic inertial sensors with extremely high sensitivity. Their performances are for the moment limited by the ground vibrations, the impact of which is exacerbated by the sequential operation, resulting in aliasing and dead time. We discuss several experiments performed at LNE-SYRTE in order to reduce these problems and achieve the intrinsic limit of…
▽ More
Developments in atom interferometry have led to atomic inertial sensors with extremely high sensitivity. Their performances are for the moment limited by the ground vibrations, the impact of which is exacerbated by the sequential operation, resulting in aliasing and dead time. We discuss several experiments performed at LNE-SYRTE in order to reduce these problems and achieve the intrinsic limit of atomic inertial sensors. These techniques have resulted in transportable and high-performance instruments that participate in gravity measurements, and pave the way to applications in inertial navigation.
△ Less
Submitted 22 January, 2016;
originally announced January 2016.
-
Influence of chirping the Raman lasers in an atom gravimeter: phase shifts due to the Raman light shift and to the finite speed of light
Authors:
B. Cheng,
P. Gillot,
S. Merlet,
F. Pereira Dos Santos
Abstract:
We present here an analysis of the influence of the frequency dependence of the Raman laser light shifts on the phase of a Raman-type atom gravimeter. Frequency chirps are applied to the Raman lasers in order to compensate gravity and ensure the resonance of the Raman pulses during the interferometer. We show that the change in the Raman light shift when this chirp is applied only to one of the tw…
▽ More
We present here an analysis of the influence of the frequency dependence of the Raman laser light shifts on the phase of a Raman-type atom gravimeter. Frequency chirps are applied to the Raman lasers in order to compensate gravity and ensure the resonance of the Raman pulses during the interferometer. We show that the change in the Raman light shift when this chirp is applied only to one of the two Raman lasers is enough to bias the gravity measurement by a fraction of $μ$Gal ($1~μ$Gal~=~$10^{-8}$~m/s$^2$). We also show that this effect is not compensated when averaging over the two directions of the Raman wavevector $k$. This thus constitutes a limit to the rejection efficiency of the $k$-reversal technique. Our analysis allows us to separate this effect from the effect of the finite speed of light, which we find in perfect agreement with expected values. This study highlights the benefit of chirping symmetrically the two Raman lasers.
△ Less
Submitted 16 October, 2015; v1 submitted 10 June, 2015;
originally announced June 2015.
-
Hybridizing matter-wave and classical accelerometers
Authors:
Jean Lautier,
Laurent Volodimer,
Thomas Hardin,
Sebastien Merlet,
Michel Lours,
Franck Pereira Dos Santos,
Arnaud Landragin
Abstract:
We demonstrate a hybrid accelerometer that benefits from the advantages of both conventional and atomic sensors in terms of bandwidth (DC to 430 Hz) and long term stability. First, the use of a real time correction of the atom interferometer phase by the signal from the classical accelerometer enables to run it at best performances without any isolation platform. Second, a servo-lock of the DC com…
▽ More
We demonstrate a hybrid accelerometer that benefits from the advantages of both conventional and atomic sensors in terms of bandwidth (DC to 430 Hz) and long term stability. First, the use of a real time correction of the atom interferometer phase by the signal from the classical accelerometer enables to run it at best performances without any isolation platform. Second, a servo-lock of the DC component of the conventional sensor output signal by the atomic one realizes a hybrid sensor. This method paves the way for applications in geophysics and in inertial navigation as it overcomes the main limitation of atomic accelerometers, namely the dead times between consecutive measurements.
△ Less
Submitted 6 October, 2014; v1 submitted 30 September, 2014;
originally announced October 2014.
-
Effective velocity distribution in an atom gravimeter: effect of the convolution with the response of the detection
Authors:
Tristan Farah,
Pierre Gillot,
Bing Cheng,
Arnaud Landragin,
Sébastien Merlet,
Franck Pereira Dos Santos
Abstract:
We present here a detailed study of the influence of the transverse motion of the atoms in a free-fall gravimeter. By implementing Raman selection in the horizontal directions at the beginning of the atoms free fall, we characterize the effective velocity distribution, ie the velocity distribution of the detected atom, as a function of the laser cooling and trapping parameters. In particular, we s…
▽ More
We present here a detailed study of the influence of the transverse motion of the atoms in a free-fall gravimeter. By implementing Raman selection in the horizontal directions at the beginning of the atoms free fall, we characterize the effective velocity distribution, ie the velocity distribution of the detected atom, as a function of the laser cooling and trapping parameters. In particular, we show that the response of the detection induces a pronounced asymetry of this effective velocity distribution that depends not only on the imbalance between molasses beams but also on the initial position of the displaced atomic sample. This convolution with the detection has a strong influence on the averaging of the bias due to Coriolis acceleration. The present study allows a fairly good understanding of results previously published in {\it Louchet-Chauvet et al., NJP 13, 065025 (2011)}, where the mean phase shift due to Coriolis acceleration was found to have a sign different from expected.
△ Less
Submitted 23 June, 2014;
originally announced June 2014.
-
A simple laser system for atom interferometry
Authors:
Sébastien Merlet,
Laurent Volodimer,
Michel Lours,
Franck Pereira Dos Santos
Abstract:
We present here a simple laser system for a laser cooled atom interferometer, where all functions (laser cooling, interferometry and detection) are realized using only two extended cavity laser diodes, amplified by a common tapered amplifier. One laser is locked by frequency modulation transfer spectroscopy, the other being phase locked with an offset frequency determined by an Field-Programmable…
▽ More
We present here a simple laser system for a laser cooled atom interferometer, where all functions (laser cooling, interferometry and detection) are realized using only two extended cavity laser diodes, amplified by a common tapered amplifier. One laser is locked by frequency modulation transfer spectroscopy, the other being phase locked with an offset frequency determined by an Field-Programmable Gate Array (FPGA) controlled Direct Digital Synthesizer (DDS), which allows for efficient and versatile tuning of the laser frequency. Raman lasers are obtained with a double pass acousto-optic modulator. We demonstrate a gravimeter using this laser system, with performances close to the state of the art.
△ Less
Submitted 23 June, 2014;
originally announced June 2014.
-
Stability comparison of two absolute gravimeters: optical versus atomic interferometers
Authors:
Pierre Gillot,
Olivier Francis,
Arnaud Landragin,
Franck Pereira Dos Santos,
Sébastien Merlet
Abstract:
We report the direct comparison between the stabilities of two mobile absolute gravimeters of different technology: the LNE-SYRTE Cold Atom Gravimeter and FG5X\#216 of the Université du Luxembourg. These instruments rely on two different principles of operation: atomic and optical interferometry. The comparison took place in the Walferdange Underground Laboratory for Geodynamics in Luxembourg, at…
▽ More
We report the direct comparison between the stabilities of two mobile absolute gravimeters of different technology: the LNE-SYRTE Cold Atom Gravimeter and FG5X\#216 of the Université du Luxembourg. These instruments rely on two different principles of operation: atomic and optical interferometry. The comparison took place in the Walferdange Underground Laboratory for Geodynamics in Luxembourg, at the beginning of the last International Comparison of Absolute Gravimeters, ICAG-2013. We analyse a 2h10 duration common measurement, and find that the CAG shows better immunity with respect to changes in the level of vibration noise, as well as a slightly better short term stability.
△ Less
Submitted 19 June, 2014;
originally announced June 2014.
-
Underground operation at best sensitivity of the mobile LNE-SYRTE Cold Atom Gravimeter
Authors:
Tristan Farah,
Christine Guerlin,
Arnaud Landragin,
Philippe Bouyer,
Stéphane Gaffet,
Franck Pereira Dos Santos,
Sébastien Merlet
Abstract:
Low noise underground environments offer conditions allowing to assess ultimate performance of high sensitivity sensors such as accelerometers, gyrometers, seismometers... Such facilities are for instance ideal for observing the tiny signals of interest for geophysical studies. Laboratoire Souterrain à Bas Bruit (LSBB) in which we have installed our cold atom gravimeter, provides such an environme…
▽ More
Low noise underground environments offer conditions allowing to assess ultimate performance of high sensitivity sensors such as accelerometers, gyrometers, seismometers... Such facilities are for instance ideal for observing the tiny signals of interest for geophysical studies. Laboratoire Souterrain à Bas Bruit (LSBB) in which we have installed our cold atom gravimeter, provides such an environment. We report here the best short term sensitivity ever obtained without any ground vibration isolation system with such an instrument: $10^{-8}$m.s$^{-2}$ in 100 s measurement time.
△ Less
Submitted 27 April, 2014;
originally announced April 2014.
-
Perturbations of the local gravity field due to mass distribution on precise measuring instruments: a numerical method applied to a cold atom gravimeter
Authors:
G. D'Agostino,
S. Merlet,
A. Landragin,
F. Pereira Dos Santos
Abstract:
We present a numerical method, based on a FEM simulation, for the determination of the gravitational field generated by massive objects, whatever geometry and space mass density they have. The method was applied for the determination of the self gravity effect of an absolute cold atom gravimeter which aims at a relative uncertainty of 10-9. The deduced bias, calculated with a perturbative treatmen…
▽ More
We present a numerical method, based on a FEM simulation, for the determination of the gravitational field generated by massive objects, whatever geometry and space mass density they have. The method was applied for the determination of the self gravity effect of an absolute cold atom gravimeter which aims at a relative uncertainty of 10-9. The deduced bias, calculated with a perturbative treatment, is finally presented. The perturbation reaches (1.3 \pm 0.1) \times 10-9 of the Earth's gravitational field.
△ Less
Submitted 11 May, 2011;
originally announced May 2011.
-
Comparison of 3 absolute gravimeters based on different methods for the e-MASS project
Authors:
A. Louchet-Chauvet,
S. Merlet,
Q. Bodart,
A. Landragin,
F. Pereira Dos Santos,
H. Baumann,
G. D'Agostino,
C. Origlia
Abstract:
We report on the comparison between three absolute gravimeters that took place in April 2010 at Laboratoire National de Métrologie et d'Essais. The three instruments (FG5#209 from METAS, Switzerland, IMGC-02 from INRIM, Italy, and CAG from LNE-SYRTE, France) rely on different methods: optical and atomic interferometry. We discuss their differences as well as their similarities. We compare their me…
▽ More
We report on the comparison between three absolute gravimeters that took place in April 2010 at Laboratoire National de Métrologie et d'Essais. The three instruments (FG5#209 from METAS, Switzerland, IMGC-02 from INRIM, Italy, and CAG from LNE-SYRTE, France) rely on different methods: optical and atomic interferometry. We discuss their differences as well as their similarities. We compare their measurements of the gravitational acceleration in 4 points of the same pillar, in the perspective of an absolute determination of g for a watt balance experiment
△ Less
Submitted 23 November, 2010; v1 submitted 17 August, 2010;
originally announced August 2010.
-
Comparison between two mobile absolute gravimeters: optical versus atomic interferometers
Authors:
S. Merlet,
Q. Bodart,
N. Malossi,
A. Landragin,
F. Pereira Dos Santos,
O. Gitlein,
L. Timmen
Abstract:
We report a comparison between two absolute gravimeters: the LNE-SYRTE cold atoms gravimeter and FG5#220 of Leibniz Universität of Hannover. They rely on different principles of operation: atomic and optical interferometry. Both are movable which enabled them to participated to the last International Comparison of Absolute Gravimeters (ICAG'09) at BIPM. Immediately after, their bilateral compariso…
▽ More
We report a comparison between two absolute gravimeters: the LNE-SYRTE cold atoms gravimeter and FG5#220 of Leibniz Universität of Hannover. They rely on different principles of operation: atomic and optical interferometry. Both are movable which enabled them to participated to the last International Comparison of Absolute Gravimeters (ICAG'09) at BIPM. Immediately after, their bilateral comparison took place in the LNE watt balance laboratory and showed an agreement of 4.3 +/- 6.4 μGal.
△ Less
Submitted 28 June, 2010; v1 submitted 3 May, 2010;
originally announced May 2010.
-
A cold atom pyramidal gravimeter with a single laser beam
Authors:
Quentin Bodart,
Sébastien Merlet,
Nicola Malossi,
Franck Pereira Dos Santos,
Philippe Bouyer,
Arnaud Landragin
Abstract:
We demonstrate a scheme for realizing a compact cold atom gravimeter. The use of a hollow pyramidal configuration allows to achieve all functions: trapping, interferometer and detection with a unique laser beam leading to a drastic reduction in complexity and volume. In particular, we demonstrate a relative sensitivity to acceleration of gravity (g) of 1.7 x 10-7 at one second, with a moderate las…
▽ More
We demonstrate a scheme for realizing a compact cold atom gravimeter. The use of a hollow pyramidal configuration allows to achieve all functions: trapping, interferometer and detection with a unique laser beam leading to a drastic reduction in complexity and volume. In particular, we demonstrate a relative sensitivity to acceleration of gravity (g) of 1.7 x 10-7 at one second, with a moderate laser power of 50 mW. This simple geometry combined to such a high sensitivity opens wide perspectives for practical applications (P. Bouyer and A. Landragin, patent number FR2009/000252, 2009).
△ Less
Submitted 29 April, 2010;
originally announced April 2010.
-
Double diffraction in an atomic gravimeter
Authors:
Nicola Malossi,
Quentin Bodart,
Sébastien Merlet,
Thomas Lévèque,
Arnaud Landragin,
Franck Pereira Dos Santos
Abstract:
We demonstrate the realization of a new scheme for cold atom gravimetry based on the use of double diffraction beamsplitters recently demonstrated in \cite{Leveque}, where the use of two retro-reflected Raman beams allows symmetric diffraction in $\pm \hbar k_{eff}$ momenta. Though in principle restricted to the case of zero Doppler shift, for which the two pairs of Raman beams are simultaneousl…
▽ More
We demonstrate the realization of a new scheme for cold atom gravimetry based on the use of double diffraction beamsplitters recently demonstrated in \cite{Leveque}, where the use of two retro-reflected Raman beams allows symmetric diffraction in $\pm \hbar k_{eff}$ momenta. Though in principle restricted to the case of zero Doppler shift, for which the two pairs of Raman beams are simultaneously resonant, we demonstrate that such diffraction pulses can remain efficient on atoms with non zero velocity, such as in a gravimeter, when modulating the frequency of one of the two Raman laser sources. We use such pulses to realize an interferometer insensitive to laser phase noise and some of the dominant systematics. This reduces the technical requirements and would allow the realization of a simple atomic gravimeter. We demonstrate a sensitivity of $1.2\times10^{-7}g$ per shot.
△ Less
Submitted 21 November, 2009; v1 submitted 1 September, 2009;
originally announced September 2009.
-
Operating an atom interferometer beyond its linear range
Authors:
Sébastien Merlet,
J. Le Gouët,
Quentin Bodart,
Andre Clairon,
Arnaud Landragin,
Franck Pereira Dos Santos,
Pierre Rouchon
Abstract:
In this paper, we show that an atom interferometer inertial sensor, when associated to the auxiliary measurement of external vibrations, can be operated beyond its linear range and still keep a high acceleration sensitivity. We propose and compare two measurement procedures (fringe fitting and nonlinear lock) that can be used to extract the mean phase of the interferometer when the interferomete…
▽ More
In this paper, we show that an atom interferometer inertial sensor, when associated to the auxiliary measurement of external vibrations, can be operated beyond its linear range and still keep a high acceleration sensitivity. We propose and compare two measurement procedures (fringe fitting and nonlinear lock) that can be used to extract the mean phase of the interferometer when the interferometer phase fluctuations exceed $2π$. Despite operating in the urban environment of inner Paris without any vibration isolation, the use of a low noise seismometer for the measurement of ground vibrations allows our atom gravimeter to reach at night a sensitivity as good as $5.5\times10^{-8}$g at 1 s. Robustness of the measurement to large vibration noise is also demonstrated by the ability of our gravimeter to operate during an earthquake with excellent sensitivity. Our high repetition rate allows for recovering the true low frequency seismic vibrations, ensuring proper averaging. Such techniques open new perspectives for applications in other fields, such as navigation and geophysics.
△ Less
Submitted 1 June, 2008;
originally announced June 2008.
-
Limits to the sensitivity of a low noise compact atomic gravimeter
Authors:
J. Le Gouët,
Tanja Mehlstäubler,
Jaewan Kim,
Sébastien Merlet,
Andre Clairon,
Arnaud Landragin,
Franck Pereira Dos Santos
Abstract:
A detailed analysis of the most relevant sources of phase noise in an atomic interferometer is carried out, both theoretically and experimentally. Even a short interrogation time of 100 ms allows our cold atom gravimeter to reach an excellent short term sensitivity to acceleration of $1.4\times 10^{-8}$g at 1s. This result relies on the combination of a low phase noise laser system, efficient de…
▽ More
A detailed analysis of the most relevant sources of phase noise in an atomic interferometer is carried out, both theoretically and experimentally. Even a short interrogation time of 100 ms allows our cold atom gravimeter to reach an excellent short term sensitivity to acceleration of $1.4\times 10^{-8}$g at 1s. This result relies on the combination of a low phase noise laser system, efficient detection scheme and good shielding from vibrations. In particular, we describe a simple and robust technique of vibration compensation, which is based on correcting the interferometer signal by using the AC acceleration signal measured by a low noise seismometer.
△ Less
Submitted 8 January, 2008;
originally announced January 2008.