-
GRB Redshift Classifier to Follow-up High-Redshift GRBs Using Supervised Machine Learning
Authors:
Maria Giovanna Dainotti,
Shubham Bhardwaj,
Christopher Cook,
Joshua Ange,
Nishan Lamichhane,
Malgorzata Bogdan,
Monnie McGee,
Pavel Nadolsky,
Milind Sarkar,
Agnieszka Pollo,
Shigehiro Nagataki
Abstract:
Gamma-ray bursts (GRBs) are intense, short-lived bursts of gamma-ray radiation observed up to a high redshift ($z \sim 10$) due to their luminosities. Thus, they can serve as cosmological tools to probe the early Universe. However, we need a large sample of high$-z$ GRBs, currently limited due to the difficulty in securing time at the large aperture Telescopes. Thus, it is painstaking to determine…
▽ More
Gamma-ray bursts (GRBs) are intense, short-lived bursts of gamma-ray radiation observed up to a high redshift ($z \sim 10$) due to their luminosities. Thus, they can serve as cosmological tools to probe the early Universe. However, we need a large sample of high$-z$ GRBs, currently limited due to the difficulty in securing time at the large aperture Telescopes. Thus, it is painstaking to determine quickly whether a GRB is high$z$ or low$-z$, which hampers the possibility of performing rapid follow-up observations. Previous efforts to distinguish between high$-$ and low$-z$ GRBs using GRB properties and machine learning (ML) have resulted in limited sensitivity. In this study, we aim to improve this classification by employing an ensemble ML method on 251 GRBs with measured redshifts and plateaus observed by the Neil Gehrels Swift Observatory. Incorporating the plateau phase with the prompt emission, we have employed an ensemble of classification methods to enhance the sensitivity unprecedentedly. Additionally, we investigate the effectiveness of various classification methods using different redshift thresholds, $z_{threshold}$=$z_t$ at $z_{t}=$ 2.0, 2.5, 3.0, and 3.5. We achieve a sensitivity of 87\% and 89\% with a balanced sampling for both $z_{t}=3.0$ and $z_{t}=3.5$, respectively, representing a 9\% and 11\% increase in the sensitivity over Random Forest used alone. Overall, the best results are at $z_{t} = 3.5$, where the difference between the sensitivity of the training set and the test set is the smallest. This enhancement of the proposed method paves the way for new and intriguing follow-up observations of high$-z$ GRBs.
△ Less
Submitted 16 August, 2024;
originally announced August 2024.
-
Analysis of Compositional Data with Positive Correlations among Components using a Nested Dirichlet Distribution with Application to a Morris Water Maze Experiment
Authors:
Jacob A. Turner,
Bianca A. Luedeker,
Monnie McGee
Abstract:
In a typical Morris water maze experiment, a mouse is placed in a circular water tank and allowed to swim freely until it finds a platform, triggering a route of escape from the tank. For reference purposes, the tank is divided into four quadrants: the target quadrant where the trigger to escape resides, the opposite quadrant to the target, and two adjacent quadrants. Several response variables ca…
▽ More
In a typical Morris water maze experiment, a mouse is placed in a circular water tank and allowed to swim freely until it finds a platform, triggering a route of escape from the tank. For reference purposes, the tank is divided into four quadrants: the target quadrant where the trigger to escape resides, the opposite quadrant to the target, and two adjacent quadrants. Several response variables can be measured: the amount of time that a mouse spends in different quadrants of the water tank, the number of times the mouse crosses from one quadrant to another, or how quickly a mouse triggers an escape from the tank. When considering time within each quadrant, it is hypothesized that normal mice will spend smaller amounts of time in quadrants that do not contain the escape route, while mice with an acquired or induced mental deficiency will spend equal time in all quadrants of the tank. Clearly, proportion of time in the quadrants must sum to one and are therefore statistically dependent; however, most analyses of data from this experiment treat time in quadrants as statistically independent. A recent paper introduced a hypothesis testing method that involves fitting such data to a Dirichlet distribution. While an improvement over studies that ignore the compositional structure of the data, we show that methodology is flawed. We introduce a two-sample test to detect differences in proportion of components for two independent groups where both groups are from either a Dirichlet or nested Dirichlet distribution. This new test is used to reanalyze the data from a previous study and come to a different conclusion.
△ Less
Submitted 9 January, 2024;
originally announced January 2024.
-
Measuring Sources of Bias in Diving Competitions
Authors:
Monnie McGee,
Gabe Downey,
Zachary Berg
Abstract:
We examine bias in diving scores from high school meets. Usually, examination of bias in sports where judges assign subjective scores has been examined in terms of nationalistic bias, where judges award favorable scores to athletes from their own home countries. In this work, bias is defined as difference between the judge's scores for a given meet and the ability of the diver. As a measure of the…
▽ More
We examine bias in diving scores from high school meets. Usually, examination of bias in sports where judges assign subjective scores has been examined in terms of nationalistic bias, where judges award favorable scores to athletes from their own home countries. In this work, bias is defined as difference between the judge's scores for a given meet and the ability of the diver. As a measure of the ability of a diver, we calculate a mean score for all dives and all meets in which the diver has participated. We call this mean score a diver's competency score. We use the difference between judges' scores within a given meet and the diver's competency to define a discrepancy: the difference between a judge's estimation of a diver's ability and their true ability. We examine this discrepancy with respect to age, gender, direction of dive, position of dive, round of competition, and dive difficulty.
△ Less
Submitted 12 October, 2023;
originally announced October 2023.
-
Information Sources and Anxiety among Refugees in Kenya during COVID-19
Authors:
Matthew A. McGee,
Carleen Maitland,
Dorothy Njoroge
Abstract:
In the COVID-19 pandemic, refugees' access to information has become increasingly important given the rapid change in the scientific and public health knowledge-base. However, this access is complicated by social distancing requirements that disrupt traditional in-person communication. Many refugees must then rely on alternative information sources to stay informed. Differences in media types and…
▽ More
In the COVID-19 pandemic, refugees' access to information has become increasingly important given the rapid change in the scientific and public health knowledge-base. However, this access is complicated by social distancing requirements that disrupt traditional in-person communication. Many refugees must then rely on alternative information sources to stay informed. Differences in media types and information sources in turn may be related to anxieties arising from the virus and perceptions of others' adherence to recommended protective behaviors. We examine these relationships with survey data from 1,000 refugees living in both camps and non-camp settings in Kenya. Using logit models, we test relationships between information source and anxiety and the effect of these variables on refugees' expected behaviors of community members. Our primary contributions include the finding that information sources consistently exacerbate (e.g., Facebook) or ameliorate (e.g., news from the internet) different anxieties, or can have mixed effects (e.g., radio). We also find that anxiety and information have significant impacts on refugees' expectations of compliance by others and that, whether between camps or between camps and non-camp locales, findings vary by location. Our results have implications for refugee media and infectious disease anxiety scholarship as well as for managing infectious disease response.
△ Less
Submitted 23 August, 2021;
originally announced August 2021.
-
Interstitial cells and neurons respond to variations in hydration
Authors:
Maria P McGee,
Michael Morykwas,
Mary Kerns,
Anirudh Vashisht,
Ashok N Hegde,
Louis Argenta
Abstract:
Dehydration and brain interstitial fluid alterations associate to cognitive dysfunction. We now explore whether changes in matrix hydration are a possible common signal for modulation of water-transfer rates and neuron function.
Dehydration and brain interstitial fluid alterations associate to cognitive dysfunction. We now explore whether changes in matrix hydration are a possible common signal for modulation of water-transfer rates and neuron function.
△ Less
Submitted 27 April, 2020;
originally announced April 2020.
-
A Simple Correction Procedure for High-Dimensional Generalized Linear Models with Measurement Error
Authors:
Michael Byrd,
Monnie McGee
Abstract:
We consider high-dimensional generalized linear models when the covariates are contaminated by measurement error. Estimates from errors-in-variables regression models are well-known to be biased in traditional low-dimensional settings if the error is unincorporated. Such models have recently become of interest when regularizing penalties are added to the estimation procedure. Unfortunately, correc…
▽ More
We consider high-dimensional generalized linear models when the covariates are contaminated by measurement error. Estimates from errors-in-variables regression models are well-known to be biased in traditional low-dimensional settings if the error is unincorporated. Such models have recently become of interest when regularizing penalties are added to the estimation procedure. Unfortunately, correcting for the mismeasurements can add undue computational difficulties onto the optimization, which a new tool set for practitioners to successfully use the models. We investigate a general procedure that utilizes the recently proposed Imputation-Regularized Optimization algorithm for high-dimensional errors-in-variables models, which we implement for continuous, binary, and count response type. Crucially, our method allows for off-the-shelf linear regression methods to be employed in the presence of contaminated covariates. We apply our correction to gene microarray data, and illustrate that it results in a great reduction in the number of false positives whilst still retaining most true positives.
△ Less
Submitted 2 January, 2020; v1 submitted 25 December, 2019;
originally announced December 2019.
-
Accelerator Vacuum Windows: A Review of Past Research and a Strategy for the Development of a New Design for Improved Safety and Longevity for Particle Accelerators
Authors:
C. R. Ader,
M. Alvarez,
J. S. Batko,
R. Campos,
M. W. McGee,
A. Watts
Abstract:
Vacuum window research continues at Fermilab and this paper will examine cost effective, consistent designs which can have a huge impact on accelerator laboratories in terms of safety and cost. Issues such as the design, materials, analysis, testing and fabrication are addressed, including beam scattering plots and materials cost-benefit analysis and examining different materials which can potenti…
▽ More
Vacuum window research continues at Fermilab and this paper will examine cost effective, consistent designs which can have a huge impact on accelerator laboratories in terms of safety and cost. Issues such as the design, materials, analysis, testing and fabrication are addressed, including beam scattering plots and materials cost-benefit analysis and examining different materials which can potentially be substitutes for beryllium. A previous research paper has examined current fabrication and design techniques and also failure modes at Fermi, and this paper examines previous research in addition to emerging technologies. Many different paths have been taken by HEP Laboratories throughout the world with varying success. The history of vacuum window development is extensive and not well defined, and a matrix of what research has already been done on materials and joint design for vacuum windows will be shown. This report finally includes a treatise for vacuum window technology and a view towards emerging designs and materials and discusses future advances of research such as fabrication techniques including additive manufacturing and ultrasonic welding. Further exploration into these would prove beneficial to developing vacuum windows that are safer and stronger while being more transparent to the beam.
△ Less
Submitted 6 December, 2019;
originally announced December 2019.
-
Bayesian Regularization of Gaussian Graphical Models with Measurement Error
Authors:
Michael Byrd,
Linh Nghiem,
Monnie McGee
Abstract:
We consider a framework for determining and estimating the conditional pairwise relationships of variables when the observed samples are contaminated with measurement error in high dimensional settings. Assuming the true underlying variables follow a multivariate Gaussian distribution, if no measurement error is present, this problem is often solved by estimating the precision matrix under sparsit…
▽ More
We consider a framework for determining and estimating the conditional pairwise relationships of variables when the observed samples are contaminated with measurement error in high dimensional settings. Assuming the true underlying variables follow a multivariate Gaussian distribution, if no measurement error is present, this problem is often solved by estimating the precision matrix under sparsity constraints. However, when measurement error is present, not correcting for it leads to inconsistent estimates of the precision matrix and poor identification of relationships. We propose a new Bayesian methodology to correct for the measurement error from the observed samples. This Bayesian procedure utilizes a recent variant of the spike-and-slab Lasso to obtain a point estimate of the precision matrix, and corrects for the contamination via the recently proposed Imputation-Regularization Optimization procedure designed for missing data. Our method is shown to perform better than the naive method that ignores measurement error in both identification and estimation accuracy. To show the utility of the method, we apply the new method to establish a conditional gene network from a microarray dataset.
△ Less
Submitted 4 July, 2019;
originally announced July 2019.
-
Overview of Fabrication Techniques and Lessons Learned With Accelerator Vacuum Windows
Authors:
C. R. Ader,
M. W. McGee,
L. E. Nobrega,
E. A. Voirin
Abstract:
Vacuum thin windows have been used in Fermilab's accelerators for decades and typically have been overlooked in terms of their criticality and fragility. Vacuum windows allow beam to pass through while creating a boundary between vacuum and air or high vacuum and low vacuum areas. The design of vacuum windows, including Titanium and Beryllium windows, will be discussed as well as fabrication, test…
▽ More
Vacuum thin windows have been used in Fermilab's accelerators for decades and typically have been overlooked in terms of their criticality and fragility. Vacuum windows allow beam to pass through while creating a boundary between vacuum and air or high vacuum and low vacuum areas. The design of vacuum windows, including Titanium and Beryllium windows, will be discussed as well as fabrication, testing, and operational concerns. Failure of windows will be reviewed as well as safety approaches to mitigating failures and extending the lifetimes of vacuum windows. Various methods of calculating the strengths of vacuum windows will be explored, including FEA.
△ Less
Submitted 23 August, 2018;
originally announced August 2018.
-
Commissioning And First Results From The Fermilab Cryomodule Test Stand
Authors:
E. R. Harms,
M. Awida,
C. Baffes,
K. Carlson,
S. Chandrasekaran,
B. Chase,
E. Cullerton,
J. Edelen,
J. Einstein-Curtis,
C. Ginsburg,
A. Grassellino,
B. Hansen,
J. Holzbauer,
S. Kazakov,
T. Khabiboulline,
M. Kucera,
J. Leibfritz,
A. Lunin,
D. McDowell,
M. McGee,
D. Nicklaus,
D. Orris,
J. Ozelis,
J. Patrick,
T. Petersen
, et al. (12 additional authors not shown)
Abstract:
A new test stand dedicated to Superconducting Radiofrequency (SRF) cryomodule testing, CMTS1, has been commissioned and is now in operation at Fermilab. The first device to be cooled down and powered in this facility is the prototype 1.3 GHz cryomodule assembled at Fermilab for LCLS-II. We describe the demonstrated capabilities of CMTS1, report on steps taken during commissioning, provide an overv…
▽ More
A new test stand dedicated to Superconducting Radiofrequency (SRF) cryomodule testing, CMTS1, has been commissioned and is now in operation at Fermilab. The first device to be cooled down and powered in this facility is the prototype 1.3 GHz cryomodule assembled at Fermilab for LCLS-II. We describe the demonstrated capabilities of CMTS1, report on steps taken during commissioning, provide an overview of first test results, and survey future plans.
△ Less
Submitted 7 May, 2018;
originally announced May 2018.
-
Cryomodule Test Stand Reduced-Magnetic Support Design At Fermilab
Authors:
M. W. McGee,
S. K. Chandrasekaran,
A. C. Crawford,
E. Harms,
J. Leibfritz,
G. Wu
Abstract:
In a partnership with SLAC National Accelerator Laboratory (SLAC) and Jefferson Lab, Fermilab will assemble and test 17 of the 35 total 1.3 GHz cryomodules for the Linac Coherent Light Source II (LCLS-II) Project. These devices will be tested at Fermilab's Cryomodule Test Facility (CMTF) within the Cryomodule Test Stand (CMTS-1) cave. The problem of magnetic pollution became one of major issues du…
▽ More
In a partnership with SLAC National Accelerator Laboratory (SLAC) and Jefferson Lab, Fermilab will assemble and test 17 of the 35 total 1.3 GHz cryomodules for the Linac Coherent Light Source II (LCLS-II) Project. These devices will be tested at Fermilab's Cryomodule Test Facility (CMTF) within the Cryomodule Test Stand (CMTS-1) cave. The problem of magnetic pollution became one of major issues during design stage of the LCLS-II cryomodule as the average quality factor of the accelerating cavities is specified to be $2.7 \times 10^{10}$. One of the possible ways to mitigate the effect of stray magnetic fields and to keep it below the goal of 5 mGauss involves the application of low permeable materials. Initial permeability and magnetic measurement studies regarding the use of 316L stainless steel material indicated that cold work (machining) and heat affected zones from welding would be acceptable.
△ Less
Submitted 25 April, 2017;
originally announced April 2017.
-
Investigation of thermal acoustic effects on SRF cavities within CM1 at Fermilab
Authors:
M. W. McGee,
E. Harms,
A. Klebaner,
J. Leibfritz,
A. Martinez,
Y. Pischalnikov,
W. Schappert
Abstract:
Radio Frequency (RF) power studies are in progress following the cryogenic commissioning of Cryomodule #1 (CM1) at Fermilab's Superconducting Radio Frequency (SRF) Accelerator Test Facility. These studies are complemented by the characterization of thermal acoustic effects on cavity microphonics manifested by apparent noisy boiling of helium involving vapor bubble and liquid vibration. The thermal…
▽ More
Radio Frequency (RF) power studies are in progress following the cryogenic commissioning of Cryomodule #1 (CM1) at Fermilab's Superconducting Radio Frequency (SRF) Accelerator Test Facility. These studies are complemented by the characterization of thermal acoustic effects on cavity microphonics manifested by apparent noisy boiling of helium involving vapor bubble and liquid vibration. The thermal acoustic measurements also consider pressure and temperature spikes which drive the phenomenon at low and high frequencies.
△ Less
Submitted 1 July, 2016;
originally announced July 2016.
-
Mechanical stability study for Integrable Optics Test Accelerator at Fermilab
Authors:
M. W. McGee,
R. Andrews,
K. Carlson,
J. Leibfritz,
L. Nobrega,
A. Valishev
Abstract:
The Integrable Optics Test Accelerator (IOTA) is proposed for operation at Fermilab. The goal of IOTA is to create practical nonlinear accelerator focusing systems with a large frequency spread and stable particle motion. The IOTA is a 40 m circumference, 150 MeV (e-), 2.5 MeV (p+) diagnostic test ring. A heavy low frequency steel floor girder is proposed as the primary tier for IOTA device compon…
▽ More
The Integrable Optics Test Accelerator (IOTA) is proposed for operation at Fermilab. The goal of IOTA is to create practical nonlinear accelerator focusing systems with a large frequency spread and stable particle motion. The IOTA is a 40 m circumference, 150 MeV (e-), 2.5 MeV (p+) diagnostic test ring. A heavy low frequency steel floor girder is proposed as the primary tier for IOTA device component support. Two design lengths; (8) 3.96 m and (2) 3.1 m long girders with identical cross section completely encompass the ring. This study focuses on the 3.96 m length girder and the development of a working prototype. Hydrostatic Level Sensor (HLS), temperature, metrology and fast motion measurements characterize the anticipated mechanical stability of the IOTA ring.
△ Less
Submitted 1 July, 2016;
originally announced July 2016.
-
Transport of LCLS-II 1.3 Ghz cryomodule to SLAC
Authors:
M. W. McGee,
T. Arkan,
T. Peterson,
Z. Tang,
S. Boo,
M. Carrasco,
E. Daly,
N. Huque
Abstract:
In a partnership with SLAC National Accelerator Laboratory (SLAC) and Jefferson Lab, Fermilab will assemble and test 17 of the 35 total 1.3 GHz cryomodules for the Linac Coherent Light Source II (LCLS-II) Project. These include a prototype built and delivered by each Lab. Another two 3.9 GHz cryomodules will be built, tested and transported by Fermilab to SLAC. Each assembly will be transported ov…
▽ More
In a partnership with SLAC National Accelerator Laboratory (SLAC) and Jefferson Lab, Fermilab will assemble and test 17 of the 35 total 1.3 GHz cryomodules for the Linac Coherent Light Source II (LCLS-II) Project. These include a prototype built and delivered by each Lab. Another two 3.9 GHz cryomodules will be built, tested and transported by Fermilab to SLAC. Each assembly will be transported over-the-road from Fermilab or Jefferson Lab using specific routes to SLAC. The transport system consists of a base frame, isolation fixture and upper protective truss. The strongback cryomodule lifting fixture is described along with other supporting equipment used for both over-the-road transport and local (on-site) transport at Fermilab. Initially, analysis of fragile components and stability studies will be performed in order to assess the risk associated with over-the-road transport of a fully assembled cryomodule.
△ Less
Submitted 30 June, 2016;
originally announced July 2016.
-
Current status of the LBNE neutrino beam
Authors:
Craig Damon Moore,
Ken Bourkland,
Cory Francis Crowley,
Patrick Hurh,
James Hylen,
Byron Lundberg,
Alberto Marchionni,
Mike McGee,
Nikolai V. Mokhov,
Vaia Papadimitriou,
Rob Plunkett,
Sarah Diane Reitzner,
Andrew M Stefanik,
Gueorgui Velev,
Karlton Williams,
Robert Miles Zwaska
Abstract:
The Long Baseline Neutrino Experiment (LBNE) will utilize a neutrino beamline facility located at Fermilab. The facility is designed to aim a beam of neutrinos toward a detector placed in South Dakota. The neutrinos are produced in a three-step process. First, protons from the Main Injector hit a solid target and produce mesons. Then, the charged mesons are focused by a set of focusing horns into…
▽ More
The Long Baseline Neutrino Experiment (LBNE) will utilize a neutrino beamline facility located at Fermilab. The facility is designed to aim a beam of neutrinos toward a detector placed in South Dakota. The neutrinos are produced in a three-step process. First, protons from the Main Injector hit a solid target and produce mesons. Then, the charged mesons are focused by a set of focusing horns into the decay pipe, towards the far detector. Finally, the mesons that enter the decay pipe decay into neutrinos. The parameters of the facility were determined by an amalgam of the physics goals, the Monte Carlo modeling of the facility, and the experience gained by operating the NuMI facility at Fermilab. The initial beam power is expected to be ~700 kW, however some of the parameters were chosen to be able to deal with a beam power of 2.3 MW. The LBNE Neutrino Beam has made significant changes to the initial design through consideration of numerous Value Engineering proposals and the current design is described.
△ Less
Submitted 6 February, 2015;
originally announced February 2015.
-
RF Test Results from Cryomodule 1 at the Fermilab SRF Beam Test Facility
Authors:
E. Harms,
K. Carlson,
B. Chase,
E. Cullerton,
A. Hocker,
C. Jensen,
P. Joireman,
A. Klebaner,
T. Kubicki,
M. Kucera,
A. Legan,
J. Leibfritz,
A. Martinez,
M. McGee,
S. Nagaitsev,
O. Nezhevenko,
D. Nicklaus,
H. Pfeffer,
Y. Pischalnikov,
P. Prieto,
J. Reid,
W. Schappert,
V. Tupikov,
P. Varghese,
J. Branlard
Abstract:
Powered operation of Cryomodule 1 (CM-1) at the Fermilab SRF Beam Test Facility began in late 2010. Since then a series of tests first on the eight individual cavities and then the full cryomodule have been performed. We report on the results of these tests and lessons learned which will have an impact on future module testing at Fermilab.
Powered operation of Cryomodule 1 (CM-1) at the Fermilab SRF Beam Test Facility began in late 2010. Since then a series of tests first on the eight individual cavities and then the full cryomodule have been performed. We report on the results of these tests and lessons learned which will have an impact on future module testing at Fermilab.
△ Less
Submitted 18 September, 2012;
originally announced September 2012.
-
Overview of the LBNE Neutrino Beam
Authors:
C. D. Moore,
Yun He,
Patrick Hurh,
James Hylen,
Byron Lundberg,
Mike McGee,
Joel Misek,
Nikolai V. Mokhov,
Vaia Papadimitriou,
Rob Plunkett,
Ryan Schultz,
Gueorgui Velev,
Karlton Williams,
Robert Miles Zwaska
Abstract:
The Long Baseline Neutrino Experiment (LBNE) will utilize a neutrino beamline facility located at Fermilab. The facility is designed to aim a beam of neutrinos toward a detector placed at the Deep Underground Science and Engineering Laboratory (DUSEL) in South Dakota. The neutrinos are produced in a three-step process. First, protons from the Main Injector hit a solid target and produce mesons. Th…
▽ More
The Long Baseline Neutrino Experiment (LBNE) will utilize a neutrino beamline facility located at Fermilab. The facility is designed to aim a beam of neutrinos toward a detector placed at the Deep Underground Science and Engineering Laboratory (DUSEL) in South Dakota. The neutrinos are produced in a three-step process. First, protons from the Main Injector hit a solid target and produce mesons. Then, the charged mesons are focused by a set of focusing horns into the decay pipe, towards the far detector. Finally, the mesons that enter the decay pipe decay into neutrinos. The parameters of the facility were determined by an amalgam of the physics goals, the Monte Carlo modeling of the facility, and the experience gained by operating the NuMI facility at Fermilab. The initial beam power is expected to be ~700 kW, however some of the parameters were chosen to be able to deal with a beam power of 2.3 MW.
△ Less
Submitted 11 September, 2012;
originally announced September 2012.
-
Vibrational measurement for commissioning SRF Accelerator Test Facility at Fermilab
Authors:
M. W. McGee,
J. Leibfritz,
A. Martinez,
Y. Pischalnikov,
W. Schappert
Abstract:
The commissioning of two cryomodule components is underway at Fermilab's Superconducting Radio Frequency (SRF) Accelerator Test Facility. The research at this facility supports the next generation high intensity linear accelerators such as the International Linear Collider (ILC), a new high intensity injector (Project X) and other future machines. These components, Cryomodule #1 (CM1) and Capture…
▽ More
The commissioning of two cryomodule components is underway at Fermilab's Superconducting Radio Frequency (SRF) Accelerator Test Facility. The research at this facility supports the next generation high intensity linear accelerators such as the International Linear Collider (ILC), a new high intensity injector (Project X) and other future machines. These components, Cryomodule #1 (CM1) and Capture Cavity II (CC2), which contain 1.3 GHz cavities are connected in series in the beamline and through cryogenic plumbing. Studies regarding characterization of ground motion, technical and cultural noise continue. Mechanical transfer functions between the foundation and critical beamline components have been measured and overall system displacement characterized. Baseline motion measurements given initial operation of cryogenic, vacuum systems and other utilities are considered.
△ Less
Submitted 9 August, 2012;
originally announced August 2012.
-
Thermal and structural stability of medium energy target carrier assembly for NOvA at Fermilab
Authors:
M. W. McGee,
C. Ader,
K. Anderson,
J. Hylen,
M. Martens
Abstract:
The NOνA project will upgrade the existing Neutrino at Main Injector (NuMI) project beamline at Fermilab to accommodate beam power of 700 kW. The Medium Energy (ME) graphite target assembly is provided through an accord with the State Research Center of Russia Institute for High Energy Physics (IHEP) at Protvino, Russia. The effects of proton beam energy deposition within beamline components are c…
▽ More
The NOνA project will upgrade the existing Neutrino at Main Injector (NuMI) project beamline at Fermilab to accommodate beam power of 700 kW. The Medium Energy (ME) graphite target assembly is provided through an accord with the State Research Center of Russia Institute for High Energy Physics (IHEP) at Protvino, Russia. The effects of proton beam energy deposition within beamline components are considered as thermal stability of the target carrier assembly and alignment budget are critical operational issues. Results of finite element thermal and structural analysis involving the target carrier assembly is provided with detail regarding the target's beryllium windows.
△ Less
Submitted 18 July, 2012;
originally announced July 2012.
-
Surface-dependent Coagulation Enzymes: Flow Kinetics of Factor Xa Generation on Live Membranes
Authors:
Maria P. McGee,
Tom Chou
Abstract:
The initial surface reactions of the extrinsic coagulation pathway on live cell membranes were examined under flow conditions. Generation of fXa (activated coagulation factor X) was measured on spherical monolayers of epithelial cells with a total surface area of 41-47 cm$^{2}$ expressing TF(tissue factor) at $>25$ fmol/cm$^{2}$. Concentrations of reactants and product were monitored as a functi…
▽ More
The initial surface reactions of the extrinsic coagulation pathway on live cell membranes were examined under flow conditions. Generation of fXa (activated coagulation factor X) was measured on spherical monolayers of epithelial cells with a total surface area of 41-47 cm$^{2}$ expressing TF(tissue factor) at $>25$ fmol/cm$^{2}$. Concentrations of reactants and product were monitored as a function of time with radiolabeled proteins and a chromogenic substrate at resolutions of 2-8 s. At physiological concentrations of fVIIa and fX, the reaction rate was $3.05 \pm 0.75$ fmol fXa/s/cm$^{2}$, independent of flux, and 10 times slower than that expected for collision-limited reactions. Rates were also independent of surface fVIIa concentrations within the range 0.6-25 fmol/cm$^{2}$. The transit time of fX activated on the reaction chamber was prolonged relative to transit times of nonreacting tracers or preformed fXa. Membrane reactions were modeled using a set of nonlinear kinetic equations and a lagged normal density curve to track the expected surface concentration of reactants for various hypothetical reaction mechanisms. The experimental results were theoretically predicted only when the models used a slow intermediate reaction step, consistent with surface diffusion. These results provide evidence that the transfer of substrate within the membrane is rate-limiting in the kinetic mechanisms leading to initiation of blood coagulation by the tissue factor pathway.
△ Less
Submitted 31 August, 2001;
originally announced September 2001.