-
Longitudinal phase-space manipulation with beam-driven plasma wakefields
Authors:
V. Shpakov,
M. P. Anania,
M. Bellaveglia,
A. Biagioni,
F. Bisesto,
F. Cardelli,
M. Cesarini,
E. Chiadroni,
A. Cianchi,
G. Costa,
M. Croia,
A. DelDotto,
D. DiGiovenale,
M. Diomede,
M. Ferrario,
F. Filippi,
A. Giribono,
V. Lollo,
M. Marongiu,
V. Martinelli,
A. Mostacci,
L. Piersanti,
G. DiPirro,
R. Pompili,
S. Romeo
, et al. (4 additional authors not shown)
Abstract:
The development of compact accelerator facilities providing high-brightness beams is one of the most challenging tasks in field of next-generation compact and cost affordable particle accelerators, to be used in many fields for industrial, medical and research applications. The ability to shape the beam longitudinal phase-space, in particular, plays a key role to achieve high-peak brightness. Here…
▽ More
The development of compact accelerator facilities providing high-brightness beams is one of the most challenging tasks in field of next-generation compact and cost affordable particle accelerators, to be used in many fields for industrial, medical and research applications. The ability to shape the beam longitudinal phase-space, in particular, plays a key role to achieve high-peak brightness. Here we present a new approach that allows to tune the longitudinal phase-space of a high-brightness beam by means of a plasma wakefields. The electron beam passing through the plasma drives large wakefields that are used to manipulate the time-energy correlation of particles along the beam itself. We experimentally demonstrate that such solution is highly tunable by simply adjusting the density of the plasma and can be used to imprint or remove any correlation onto the beam. This is a fundamental requirement when dealing with largely time-energy correlated beams coming from future plasma accelerators.
△ Less
Submitted 21 February, 2019;
originally announced February 2019.
-
Gas Distribution and Monitoring for the Drift Chamber of the MEG-II Experiment
Authors:
A. M. Baldini,
E. Baracchini,
G. Cavoto,
F. Cei,
M. Chiappini,
G. Chiarello,
C. Chiri,
M. Francesconi,
L. Galli,
F. Grancagnolo,
M. Grassi,
M. Hildebrandt,
V. Martinelli,
M. Meucci,
D. Nicolò,
M. Panareo,
A. Papa,
A. Pepino,
B. Pruneti,
F. Raffaelli,
F. Renga,
E. Ripiccini,
G. Signorelli,
G. F. Tassielli,
C. Voena
Abstract:
The reconstruction of the positron trajectory in the MEG-II experiment searching for the $μ^+ \to e^+ γ$ decay uses a cylindrical drift chamber operated with a helium-isobutane gas mixture. A stable performance of the detector in terms of its electron drift properties, avalanche multiplication, and with a gas mixture of controlled composition and purity has to be provided and continuously monitore…
▽ More
The reconstruction of the positron trajectory in the MEG-II experiment searching for the $μ^+ \to e^+ γ$ decay uses a cylindrical drift chamber operated with a helium-isobutane gas mixture. A stable performance of the detector in terms of its electron drift properties, avalanche multiplication, and with a gas mixture of controlled composition and purity has to be provided and continuously monitored. In this paper we describe the strategies adopted to meet the requirements imposed by the target sensitivity of MEG-II, including the construction and commissioning of a small chamber for an online monitoring of the gas quality.
△ Less
Submitted 23 April, 2018;
originally announced April 2018.
-
EuPRAXIA@SPARC_LAB Design study towards a compact FEL facility at LNF
Authors:
M. Ferrario,
D. Alesini,
M. P. Anania,
M. Artioli,
A. Bacci,
S. Bartocci,
R. Bedogni,
M. Bellaveglia,
A. Biagioni,
F. Bisesto,
F. Brandi,
E. Brentegani,
F. Broggi,
B. Buonomo,
P. L. Campana,
G. Campogiani,
C. Cannaos,
S. Cantarella,
F. Cardelli,
M. Carpanese,
M. Castellano,
G. Castorina,
N. Catalan Lasheras,
E. Chiadroni,
A. Cianchi
, et al. (95 additional authors not shown)
Abstract:
On the wake of the results obtained so far at the SPARC\_LAB test-facility at the Laboratori Nazionali di Frascati (Italy), we are currently investigating the possibility to design and build a new multi-disciplinary user-facility, equipped with a soft X-ray Free Electron Laser (FEL) driven by a $\sim$1 GeV high brightness linac based on plasma accelerator modules. This design study is performed in…
▽ More
On the wake of the results obtained so far at the SPARC\_LAB test-facility at the Laboratori Nazionali di Frascati (Italy), we are currently investigating the possibility to design and build a new multi-disciplinary user-facility, equipped with a soft X-ray Free Electron Laser (FEL) driven by a $\sim$1 GeV high brightness linac based on plasma accelerator modules. This design study is performed in synergy with the EuPRAXIA design study. In this paper we report about the recent progresses in the on going design study of the new facility.
△ Less
Submitted 26 January, 2018;
originally announced January 2018.
-
Recent results at SPARC_LAB
Authors:
R. Pompili,
M. P. Anania,
M. Bellaveglia,
A. Biagioni,
S. Bini,
F. Bisesto,
E. Chiadroni,
A. Cianchi,
G. Costa,
D. Di Giovenale,
M. Ferrario,
F. Filippi,
A. Gallo,
A. Giribono,
V. Lollo,
A. Marocchino,
V. Martinelli,
A. Mostacci,
G. Di Pirro,
S. Romeo,
J. Scifo,
V. Shpakov,
C. Vaccarezza,
F. Villa,
A. Zigler
Abstract:
The current activity of the SPARC_LAB test-facility is focused on the realization of plasma-based acceleration experiments with the aim to provide accelerating field of the order of several GV/m while maintaining the overall quality (in terms of energy spread and emittance) of the accelerated electron bunch. In the following, the current status of such an activity is presented. We also show result…
▽ More
The current activity of the SPARC_LAB test-facility is focused on the realization of plasma-based acceleration experiments with the aim to provide accelerating field of the order of several GV/m while maintaining the overall quality (in terms of energy spread and emittance) of the accelerated electron bunch. In the following, the current status of such an activity is presented. We also show results related to the usability of plasmas as focusing lenses in view of a complete plasma-based focusing and accelerating system.
△ Less
Submitted 18 January, 2018;
originally announced January 2018.
-
Single-hit resolution measurement with MEG II drift chamber prototypes
Authors:
A. M. Baldini,
E. Baracchini,
G. Cavoto,
M. Cascella,
F. Cei,
M. Chiappini,
G. Chiarello,
C. Chiri,
S. Dussoni,
L. Galli,
F. Grancagnolo,
M. Grassi,
V. Martinelli,
D. Nicolò,
M. Panareo,
A. Pepino,
G. Piredda,
F. Renga,
E. Ripiccini,
G. Signorelli,
G. F. Tassielli,
F. Tenchini,
M. Venturini,
C. Voena
Abstract:
Drift chambers operated with helium-based gas mixtures represent a common solution for tracking charged particles keeping the material budget in the sensitive volume to a minimum. The drawback of this solution is the worsening of the spatial resolution due to primary ionisation fluctuations, which is a limiting factor for high granularity drift chambers like the MEG II tracker. We report on the me…
▽ More
Drift chambers operated with helium-based gas mixtures represent a common solution for tracking charged particles keeping the material budget in the sensitive volume to a minimum. The drawback of this solution is the worsening of the spatial resolution due to primary ionisation fluctuations, which is a limiting factor for high granularity drift chambers like the MEG II tracker. We report on the measurements performed on three different prototypes of the MEG II drift chamber aimed at determining the achievable single-hit resolution. The prototypes were operated with helium/isobutane gas mixtures and exposed to cosmic rays, electron beams and radioactive sources. Direct measurements of the single hit resolution performed with an external tracker returned a value of 110 $μ$m, consistent with the values obtained with indirect measurements performed with the other prototypes.
△ Less
Submitted 25 May, 2016;
originally announced May 2016.