-
An $^{115}$In$^+$-$^{172}$Yb$^+$ Coulomb crystal clock with $2.5\times10^{-18}$ systematic uncertainty
Authors:
H. N. Hausser,
J. Keller,
T. Nordmann,
N. M. Bhatt,
J. Kiethe,
H. Liu,
M. von Boehn,
J. Rahm,
S. Weyers,
E. Benkler,
B. Lipphardt,
S. Doerscher,
K. Stahl,
J. Klose,
C. Lisdat,
M. Filzinger,
N. Huntemann,
E. Peik,
T. E. Mehlstäubler
Abstract:
We present a scalable mixed-species Coulomb crystal clock based on the $^1S_0$ $\leftrightarrow$ $^3P_0$ transition in $^{115}$In$^+$. $^{172}$Yb$^+$ ions are co-trapped and used for sympathetic cooling. Reproducible interrogation conditions for mixed-species Coulomb crystals are ensured by a conditional preparation sequence with permutation control. We demonstrate clock operation with a 1In$^+$-3…
▽ More
We present a scalable mixed-species Coulomb crystal clock based on the $^1S_0$ $\leftrightarrow$ $^3P_0$ transition in $^{115}$In$^+$. $^{172}$Yb$^+$ ions are co-trapped and used for sympathetic cooling. Reproducible interrogation conditions for mixed-species Coulomb crystals are ensured by a conditional preparation sequence with permutation control. We demonstrate clock operation with a 1In$^+$-3Yb$^+$ crystal, achieving a relative systematic uncertainty of $2.5\times10^{-18}$ and a relative frequency instability of $1.6\times10^{-15}/\sqrt{τ/1\;s}$. We report on an absolute frequency measurement with an uncertainty of $1.3\times10^{-16}$ and optical frequency ratios relative to the $^{171}$Yb$^+$ (E3) and $^{87}$Sr clock transitions with fractional uncertainties of $4.4$ and $4.7$ parts in 10$^{18}$, respectively. The latter are among the most precise measurements of frequency ratios to date and improve upon the previous uncertainty of the $^{115}$In$^+$/$^{87}$Sr ratio by two orders of magnitude. We also demonstrate operation with four $^{115}$In$^+$ clock ions, which reduces the instability to $9.2\times10^{-16}/\sqrt{τ/1\;s}$.
△ Less
Submitted 26 February, 2024;
originally announced February 2024.
-
Continuous optical generation of microwave signals for fountain clocks
Authors:
Burghard Lipphardt,
Patrick Walkemeyer,
Michael Kazda,
Johannes Rahm,
Stefan Weyers
Abstract:
For the optical generation of ultrastable microwave signals for fountain clocks we developed a setup, which is based on a cavity stabilized laser and a commercial frequency comb. The robust system, in operation since 2020, is locked to a 100 MHz output frequency of a hydrogen maser and provides an ultrastable 9.6 GHz signal for the interrogation of atoms in two caesium fountain clocks, acting as p…
▽ More
For the optical generation of ultrastable microwave signals for fountain clocks we developed a setup, which is based on a cavity stabilized laser and a commercial frequency comb. The robust system, in operation since 2020, is locked to a 100 MHz output frequency of a hydrogen maser and provides an ultrastable 9.6 GHz signal for the interrogation of atoms in two caesium fountain clocks, acting as primary frequency standards. Measurements reveal that the system provides a phase noise level which enables quantum projection noise limited fountain frequency instabilities at the low $10^{-14} (τ/\mathrm{s})^{-1/2}$ level. At the same time it offers largely maintenance-free operation.
△ Less
Submitted 17 August, 2023;
originally announced August 2023.
-
Evaluation of a $^{88}$Sr$^+$ optical clock with a direct measurement of the blackbody radiation shift and determination of the clock frequency
Authors:
M. Steinel,
H. Shao,
M. Filzinger,
B. Lipphardt,
M. Brinkmann,
A. Didier,
T. E. Mehlstäubler,
T. Lindvall,
E. Peik,
N. Huntemann
Abstract:
We report on an evaluation of an optical clock that uses the $\phantom{}^2S_{1/2} \rightarrow \phantom{}^2D_{5/2}$ transition of a single $^{88}$Sr$^+$ ion as the reference. In contrast to previous work, we estimate the effective temperature of the blackbody radiation that shifts the reference transition directly during operation from the corresponding frequency shift and the well-characterized se…
▽ More
We report on an evaluation of an optical clock that uses the $\phantom{}^2S_{1/2} \rightarrow \phantom{}^2D_{5/2}$ transition of a single $^{88}$Sr$^+$ ion as the reference. In contrast to previous work, we estimate the effective temperature of the blackbody radiation that shifts the reference transition directly during operation from the corresponding frequency shift and the well-characterized sensitivity to thermal radiation. We measure the clock output frequency against an independent $^{171}$Yb$^+$ ion clock, based on the $\phantom{}^2S_{1/2} (F=0) \rightarrow \phantom{}^2F_{7/2} (F=3)$ electric octupole (E3) transition, and determine the frequency ratio with a total fractional uncertainty of $2.3\times 10^{-17}$. Relying on a previous measurement of the $^{171}$Yb$^+$ (E3) clock frequency, we find the absolute frequency of the $^{88}$Sr$^+$ clock transition to be $444779044095485.271(59)\,\text{Hz}$. Our result reduces the uncertainty by a factor of $3$ compared to the previously most accurate measurement and may help to resolve so far inconsistent determinations of this value. We also show that for three simultaneously interrogated $^{88}$Sr$^+$ ions, the increased number causes the expected improvement of the short-term frequency instability of the optical clock without degrading its systematic uncertainty.
△ Less
Submitted 16 December, 2022;
originally announced December 2022.
-
Improved limits for violations of local position invariance from atomic clock comparisons
Authors:
R. Lange,
N. Huntemann,
J. M. Rahm,
C. Sanner,
H. Shao,
B. Lipphardt,
Chr. Tamm,
S. Weyers,
E. Peik
Abstract:
We compare two optical clocks based on the $^2$S$_{1/2}(F=0)\to {}^2$D$_{3/2}(F=2)$ electric quadrupole (E2) and the $^2$S$_{1/2}(F=0)\to {}^2$F$_{7/2}(F=3)$ electric octupole (E3) transition of $^{171}$Yb$^{+}$ and measure the frequency ratio $ν_{\mathrm{E3}}/ν_{\mathrm{E2}}=0.932\,829\,404\,530\,965\,376(32)$. We determine the transition frequency $ν_{E3}=642\,121\,496\,772\,645.10(8)$ Hz using…
▽ More
We compare two optical clocks based on the $^2$S$_{1/2}(F=0)\to {}^2$D$_{3/2}(F=2)$ electric quadrupole (E2) and the $^2$S$_{1/2}(F=0)\to {}^2$F$_{7/2}(F=3)$ electric octupole (E3) transition of $^{171}$Yb$^{+}$ and measure the frequency ratio $ν_{\mathrm{E3}}/ν_{\mathrm{E2}}=0.932\,829\,404\,530\,965\,376(32)$. We determine the transition frequency $ν_{E3}=642\,121\,496\,772\,645.10(8)$ Hz using two caesium fountain clocks. Repeated measurements of both quantities over several years are analyzed for potential violations of local position invariance. We improve by factors of about 20 and 2 the limits for fractional temporal variations of the fine structure constant $α$ to $1.0(1.1)\times10^{-18}/\mathrm{yr}$ and of the proton-to-electron mass ratio $μ$ to $-8(36)\times10^{-18}/\mathrm{yr}$. Using the annual variation of the Sun's gravitational potential at Earth $Φ$, we improve limits for a potential coupling of both constants to gravity, $(c^2/α) (dα/dΦ)=14(11)\times 10^{-9}$ and $(c^2/μ) (dμ/dΦ)=7(45)\times 10^{-8}$.
△ Less
Submitted 7 January, 2021; v1 submitted 13 October, 2020;
originally announced October 2020.
-
Optical frequency ratio of a ${}^{171}\mathrm{Yb}^+$ single-ion clock and a ${}^{87}\mathrm{Sr}$ lattice clock
Authors:
Sören Dörscher,
Nils Huntemann,
Roman Schwarz,
Richard Lange,
Erik Benkler,
Burghard Lipphardt,
Uwe Sterr,
Ekkehard Peik,
Christian Lisdat
Abstract:
We report direct measurements of the frequency ratio of the 642 THz ${}^2S_{1/2} (F=0)$--${}^2F_{7/2} (F=3)$ electric octupole transition in ${}^{171}\mathrm{Yb}^+$ and the 429 THz ${}^1S_0$--${}^3P_0$ transition in ${}^{87}\mathrm{Sr}$. A series of 107 measurements has been performed at the Physikalisch-Technische Bundesanstalt between December 2012 and October 2019. Long-term variations of the r…
▽ More
We report direct measurements of the frequency ratio of the 642 THz ${}^2S_{1/2} (F=0)$--${}^2F_{7/2} (F=3)$ electric octupole transition in ${}^{171}\mathrm{Yb}^+$ and the 429 THz ${}^1S_0$--${}^3P_0$ transition in ${}^{87}\mathrm{Sr}$. A series of 107 measurements has been performed at the Physikalisch-Technische Bundesanstalt between December 2012 and October 2019. Long-term variations of the ratio are larger than expected from the individual measurement uncertainties of few $10^{-17}$. The cause of these variations remains unknown. Even taking these into account, we find a fractional uncertainty of the frequency ratio of $2.5 \times 10^{-17}$, which improves upon previous knowledge by one order of magnitude. The average frequency ratio is $ν_{\mathrm{Yb}^+} / ν_{\mathrm{Sr}} = 1.495\,991\,618\,544\,900\,537(38)$. This represents one of the most accurate measurements between two different atomic species to date.
△ Less
Submitted 11 September, 2020;
originally announced September 2020.
-
Coherent suppression of tensor frequency shifts through magnetic field rotation
Authors:
R. Lange,
N. Huntemann,
C. Sanner,
H. Shao,
B. Lipphardt,
Chr. Tamm,
E. Peik
Abstract:
We introduce a scheme to coherently suppress second-rank tensor frequency shifts in atomic clocks, relying on the continuous rotation of an external magnetic field during the free atomic state evolution in a Ramsey sequence. The method retrieves the unperturbed frequency within a single interrogation cycle and is readily applicable to various atomic clock systems. For the frequency shift due to th…
▽ More
We introduce a scheme to coherently suppress second-rank tensor frequency shifts in atomic clocks, relying on the continuous rotation of an external magnetic field during the free atomic state evolution in a Ramsey sequence. The method retrieves the unperturbed frequency within a single interrogation cycle and is readily applicable to various atomic clock systems. For the frequency shift due to the electric quadrupole interaction, we experimentally demonstrate suppression by more than two orders of magnitude for the ${}^2S_{1/2} \to {}^2D_{3/2}$ transition of a single trapped ${}^{171}\text{Yb}^+$ ion. The scheme provides particular advantages in the case of the ${}^{171}\text{Yb}^+$ ${}^2S_{1/2} \to {}^2F_{7/2}$ electric octupole (E3) transition. For an improved estimate of the residual quadrupole shift for this transition, we measure the excited state electric quadrupole moments $Θ({}^2D_{3/2}) = 1.95(1)~ea_0^2$ and $Θ({}^2F_{7/2}) = -0.0297(5)~ea_0^2$ with $e$ the elementary charge and $a_0$ the Bohr radius, improving the measurement uncertainties by one order of magnitude.
△ Less
Submitted 29 May, 2020;
originally announced May 2020.
-
Long term measurement of the $^{87}$Sr clock frequency at the limit of primary Cs clocks
Authors:
R. Schwarz,
S. Dörscher,
A. Al-Masoudi,
E. Benkler,
T. Legero,
U. Sterr,
S. Weyers,
J. Rahm,
B. Lipphardt,
C. Lisdat
Abstract:
We report on a series of 42 measurements of the transition frequency of the 429~THz (5s$^2$)~$^1$S$_0$--(5s5p)~$^3$P$_0$ line in $^{87}$Sr taken over three years from 2017 to 2019. They have been performed at the Physikalisch-Technische Bundesanstalt (PTB) between the laboratory strontium lattice clock and the primary caesium fountain clocks CSF1 and CSF2. The length of each individual measurement…
▽ More
We report on a series of 42 measurements of the transition frequency of the 429~THz (5s$^2$)~$^1$S$_0$--(5s5p)~$^3$P$_0$ line in $^{87}$Sr taken over three years from 2017 to 2019. They have been performed at the Physikalisch-Technische Bundesanstalt (PTB) between the laboratory strontium lattice clock and the primary caesium fountain clocks CSF1 and CSF2. The length of each individual measurement run has been extended by use of a hydrogen maser as flywheel to improve the statistical uncertainty given by the Cs clocks. We determine an averaged transition frequency of $429\:228\:004\:229\:873.00(0.07)$~Hz with $1.5\times10^{-16}$ fractional uncertainty, at the limit of the current realization of the unit hertz. Analysis of the data provides an improved limit on the coupling of the gravitational potential of the Sun to the proton--electron mass ratio $μ$, and confirms the limits on its temporal drift.
△ Less
Submitted 15 May, 2020;
originally announced May 2020.
-
Direct comparisons of European primary and secondary frequency standards via satellite techniques
Authors:
F. Riedel,
A. Al-Masoudi,
E. Benkler,
S. Dörscher,
V. Gerginov,
C. Grebing,
S. Häfner,
N. Huntemann,
B. Lipphardt,
C. Lisdat,
E. Peik,
D. Piester,
C. Sanner,
C. Tamm,
S. Weyers,
H. Denker,
L. Timmen,
C. Voigt,
D. Calonico,
G. Cerretto,
G. A. Costanzo,
F. Levi,
I. Sesia,
J. Achkar,
J. Guèna
, et al. (24 additional authors not shown)
Abstract:
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taki…
▽ More
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taking into account correlations and gaps in the measurement data, combined overall uncertainties in the range of $1.8 \times 10^{-16}$ to $3.5 \times 10^{-16}$ for the optical clock comparisons were found. The comparison of the fountain clocks yields results with a maximum relative frequency difference of $6.9 \times 10^{-16}$, and combined overall uncertainties in the range of $4.8 \times 10^{-16}$ to $7.7 \times 10^{-16}$.
△ Less
Submitted 9 October, 2019;
originally announced October 2019.
-
End-to-end topology for fiber comb based optical frequency transfer at the $10^{-21}$ level
Authors:
Erik Benkler,
Burghard Lipphardt,
Thomas Puppe,
Rafał Wilk,
Felix Rohde,
Uwe Sterr
Abstract:
We introduce a simple and robust scheme for optical frequency transfer of an ultra-stable source light field via an optical frequency comb to a field at a target optical frequency, where highest stability is required, e.g. for the interrogation of an optical clock. The scheme relies on a topology for end-to-end suppression of the influence of optical path-length fluctuations, which is attained by…
▽ More
We introduce a simple and robust scheme for optical frequency transfer of an ultra-stable source light field via an optical frequency comb to a field at a target optical frequency, where highest stability is required, e.g. for the interrogation of an optical clock. The scheme relies on a topology for end-to-end suppression of the influence of optical path-length fluctuations, which is attained by actively phase-stabilized delivery, combined with common-path propagation. This approach provides a robust stability improvement without the need for additional isolation against environmental disturbances such as temperature, pressure or humidity changes. We measure residual frequency transfer instabilities by comparing the frequency transfers carried out with two independent combs simultaneously. Residual fractional frequency instabilities between two systems of $8\times10^{-18}$ at 1 s and $3\times10^{-21}$ at $10^5$ s averaging time are observed. We discuss the individual noise contributions to the residual instability. The presented scheme is technically simple, robust against environmental parameter fluctuations, and enables an ultra-stable frequency transfer, e.g. to optical clock lasers or to lasers in gravitational wave detectors.
△ Less
Submitted 1 April, 2020; v1 submitted 9 October, 2019;
originally announced October 2019.
-
Search for transient variations of the fine structure constant and dark matter using fiber-linked optical atomic clocks
Authors:
B. M. Roberts,
P. Delva,
A. Al-Masoudi,
A. Amy-Klein,
C. Bærentsen,
C. F. A. Baynham,
E. Benkler,
S. Bilicki,
S. Bize,
W. Bowden,
J. Calvert,
V. Cambier,
E. Cantin,
E. A. Curtis,
S. Dörscher,
M. Favier,
F. Frank,
P. Gill,
R. M. Godun,
G. Grosche,
C. Guo,
A. Hees,
I. R. Hill,
R. Hobson,
N. Huntemann
, et al. (29 additional authors not shown)
Abstract:
We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17…
▽ More
We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17 for transients of duration 10^3 s. This analysis also presents a possibility to search for dark matter, the mysterious substance hypothesised to explain galaxy dynamics and other astrophysical phenomena that is thought to dominate the matter density of the universe. At the current sensitivity level, we find no evidence for dark matter in the form of topological defects (or, more generally, any macroscopic objects), and we thus place constraints on certain potential couplings between the dark matter and standard model particles, substantially improving upon the existing constraints, particularly for large (>~10^4 km) objects.
△ Less
Submitted 8 July, 2019; v1 submitted 4 July, 2019;
originally announced July 2019.
-
Advances in the accuracy, stability, and reliability of the PTB primary fountain clocks
Authors:
S. Weyers,
V. Gerginov,
M. Kazda,
J. Rahm,
B. Lipphardt,
G. Dobrev,
K. Gibble
Abstract:
Improvements of the systematic uncertainty, frequency instability, and long-term reliability of the two caesium fountain primary frequency standards CSF1 and CSF2 at PTB (Physikalisch-Technische Bundesanstalt) are described. We have further investigated many of the systematic effects and made a number of modifications of the fountains. With an optically stabilized microwave oscillator, the quantum…
▽ More
Improvements of the systematic uncertainty, frequency instability, and long-term reliability of the two caesium fountain primary frequency standards CSF1 and CSF2 at PTB (Physikalisch-Technische Bundesanstalt) are described. We have further investigated many of the systematic effects and made a number of modifications of the fountains. With an optically stabilized microwave oscillator, the quantum projection noise limited frequency instabilities are improved to $7.2 \times 10^{-14} (τ/1\,\mathrm{s})^{-1/2}$ for CSF1 and $2.5 \times 10^{-14} (τ/1\,\mathrm{s})^{-1/2}$ for CSF2 at high atom density. The systematic uncertainties of CSF1 and CSF2 are reduced to $2.74 \times 10^{-16}$ and $1.71 \times 10^{-16}$, respectively. Both fountain clocks regularly calibrate the scale unit of International Atomic Time (TAI) and the local realization of Coordinated Universal Time, UTC(PTB), and serve as references to measure the frequencies of local and remote optical frequency standards.
△ Less
Submitted 10 September, 2018;
originally announced September 2018.
-
First international comparison of fountain primary frequency standards via a long distance optical fiber link
Authors:
J. Guéna,
S. Weyers,
M. Abgrall,
C. Grebing,
V. Gerginov,
P. Rosenbusch,
S. Bize,
B. Lipphardt,
H. Denker,
N. Quintin,
S. M. F. Raupach,
D. Nicolodi,
F. Stefani,
N. Chiodo,
S. Koke,
A. Kuhl,
F. Wiotte,
F. Meynadier,
E. Camisard,
C. Chardonnet,
Y. Le Coq,
M. Lours,
G. Santarelli,
A. Amy-Klein,
R. Le Targat
, et al. (3 additional authors not shown)
Abstract:
We report on the first comparison of distant caesium fountain primary frequency standards (PFSs) via an optical fiber link. The 1415 km long optical link connects two PFSs at LNE-SYRTE (Laboratoire National de métrologie et d'Essais - SYstème de Références Temps-Espace) in Paris (France) with two at PTB (Physikalisch-Technische Bundesanstalt) in Braunschweig (Germany). For a long time, these PFSs…
▽ More
We report on the first comparison of distant caesium fountain primary frequency standards (PFSs) via an optical fiber link. The 1415 km long optical link connects two PFSs at LNE-SYRTE (Laboratoire National de métrologie et d'Essais - SYstème de Références Temps-Espace) in Paris (France) with two at PTB (Physikalisch-Technische Bundesanstalt) in Braunschweig (Germany). For a long time, these PFSs have been major contributors to accuracy of the International Atomic Time (TAI), with stated accuracies of around $3\times 10^{-16}$. They have also been the references for a number of absolute measurements of clock transition frequencies in various optical frequency standards in view of a future redefinition of the second. The phase coherent optical frequency transfer via a stabilized telecom fiber link enables far better resolution than any other means of frequency transfer based on satellite links. The agreement for each pair of distant fountains compared is well within the combined uncertainty of a few 10$^{-16}$ for all the comparisons, which fully supports the stated PFSs' uncertainties. The comparison also includes a rubidium fountain frequency standard participating in the steering of TAI and enables a new absolute determination of the $^{87}$Rb ground state hyperfine transition frequency with an uncertainty of $3.1\times 10^{-16}$.
This paper is dedicated to the memory of André Clairon, who passed away on the 24$^{th}$ of December 2015, for his pioneering and long-lasting efforts in atomic fountains. He also pioneered optical links from as early as 1997.
△ Less
Submitted 14 March, 2017; v1 submitted 2 March, 2017;
originally announced March 2017.
-
Optical Stabilization of a Microwave Oscillator for Fountain Clock Interrogation
Authors:
Burghard Lipphardt,
Vladislav Gerginov,
Stefan Weyers
Abstract:
We describe an optical frequency stabilization scheme of a microwave oscillator that is used for the interrogation of primary caesium fountain clocks. Because of its superior phase noise properties, this scheme, which is based on an ultrastable laser and a femtosecond laser frequency comb, overcomes the frequency instability limitations of fountain clocks given by the previously utilized quartz-os…
▽ More
We describe an optical frequency stabilization scheme of a microwave oscillator that is used for the interrogation of primary caesium fountain clocks. Because of its superior phase noise properties, this scheme, which is based on an ultrastable laser and a femtosecond laser frequency comb, overcomes the frequency instability limitations of fountain clocks given by the previously utilized quartz-oscillator-based frequency synthesis. The presented scheme combines the transfer of the short-term frequency instability of an optical cavity and the long-term frequency instability of a hydrogen maser to the microwave oscillator and is designed to provide continuous long-term operation for extended measurement periods of several weeks. The utilization of the twofold stabilization scheme on the one hand ensures the referencing of the fountain frequency to the hydrogen maser frequency and on the other hand results in a phase noise level of the fountain interrogation signal, which enables fountain frequency instabilities at the $2.5 \times 10^{-14} (τ/\mathrm{s})^{-1/2}$ level which are quantum projection noise limited.
△ Less
Submitted 15 November, 2016; v1 submitted 19 September, 2016;
originally announced September 2016.
-
Single-Ion Atomic Clock with $3\times10^{-18}$ Systematic Uncertainty
Authors:
N. Huntemann,
C. Sanner,
B. Lipphardt,
Chr. Tamm,
E. Peik
Abstract:
We experimentally investigate an optical frequency standard based on the $^2S_{1/2} (F=0)\to {}^2F_{7/2} (F=3)$ electric octupole (\textit{E}3) transition of a single trapped $^{171}$Yb$^+$ ion. For the spectroscopy of this strongly forbidden transition, we utilize a Ramsey-type excitation scheme that provides immunity to probe-induced frequency shifts. The cancellation of these shifts is controll…
▽ More
We experimentally investigate an optical frequency standard based on the $^2S_{1/2} (F=0)\to {}^2F_{7/2} (F=3)$ electric octupole (\textit{E}3) transition of a single trapped $^{171}$Yb$^+$ ion. For the spectroscopy of this strongly forbidden transition, we utilize a Ramsey-type excitation scheme that provides immunity to probe-induced frequency shifts. The cancellation of these shifts is controlled by interleaved single-pulse Rabi spectroscopy which reduces the related relative frequency uncertainty to $1.1\times 10^{-18}$. To determine the frequency shift due to thermal radiation emitted by the ion's environment, we measure the static scalar differential polarizability of the \textit{E}3 transition as $0.888(16)\times 10^{-40}$ J m$^2$/V$^2$ and a dynamic correction $η(300~\text{K})=-0.0015(7)$. This reduces the uncertainty due to thermal radiation to $1.8\times 10^{-18}$. The residual motion of the ion yields the largest contribution $(2.1\times 10^{-18})$ to the total systematic relative uncertainty of the clock of $3.2\times 10^{-18}$.
△ Less
Submitted 11 February, 2016;
originally announced February 2016.
-
Realization of a time-scale with an accurate optical lattice clock
Authors:
C. Grebing,
A. Al-Masoudi,
S. Dörscher,
S. Häfner,
V. Gerginov,
S. Weyers,
B. Lipphardt,
F. Riehle,
U. Sterr,
C. Lisdat
Abstract:
Optical clocks are not only powerful tools for prime fundamental research, but are also deemed for the re-definition of the SI base unit second as they now surpass the performance of caesium atomic clocks in both accuracy and stability by more than an order of magnitude. However, an important obstacle in this transition has so far been the limited reliability of the optical clocks that made a cont…
▽ More
Optical clocks are not only powerful tools for prime fundamental research, but are also deemed for the re-definition of the SI base unit second as they now surpass the performance of caesium atomic clocks in both accuracy and stability by more than an order of magnitude. However, an important obstacle in this transition has so far been the limited reliability of the optical clocks that made a continuous realization of a timescale impractical. In this paper, we demonstrate how this situation can be resolved and that a timescale based on an optical clock can be established that is superior to one based on even the best caesium fountain clocks. The paper also gives further proof of the international consistency of strontium lattice clocks on the $10^{-16}$ accuracy level, which is another prerequisite for a change in the definition of the second.
△ Less
Submitted 22 February, 2016; v1 submitted 12 November, 2015;
originally announced November 2015.
-
Frequency comparison of ${}^{171}$Yb${}^+$ ion optical clocks at PTB and NPL via GPS PPP
Authors:
J. Leute,
N. Huntemann,
B. Lipphardt,
Chr. Tamm,
P. B. R. Nisbet-Jones,
S. A. King,
R. M. Godun,
J. M. Jones,
H. S. Margolis,
P. B. Whibberley,
A. Wallin,
M. Merimaa,
P. Gill,
E. Peik
Abstract:
We used Precise Point Positioning, a well-established GPS carrier-phase frequency transfer method to perform a direct remote comparison of two optical frequency standards based on single laser-cooled $^{171}$Yb$^+$ ions operated at NPL, UK and PTB, Germany. At both institutes an active hydrogen maser serves as a flywheel oscillator; it is connected to a GPS receiver as an external frequency refere…
▽ More
We used Precise Point Positioning, a well-established GPS carrier-phase frequency transfer method to perform a direct remote comparison of two optical frequency standards based on single laser-cooled $^{171}$Yb$^+$ ions operated at NPL, UK and PTB, Germany. At both institutes an active hydrogen maser serves as a flywheel oscillator; it is connected to a GPS receiver as an external frequency reference and compared simultaneously to a realization of the unperturbed frequency of the ${{}^2S_{1/2}(F=0)-{}^2D_{3/2}(F=2)}$ electric quadrupole transition in ${}^{171}$Yb${}^+$ via an optical femtosecond frequency comb. To profit from long coherent GPS link measurements we extrapolate over the various data gaps in the optical clock to maser comparisons which introduces maser noise to the frequency comparison but improves the uncertainty from the GPS link. We determined the total statistical uncertainty consisting of the GPS link uncertainty and the extrapolation uncertainties for several extrapolation schemes. Using the extrapolation scheme with the smallest combined uncertainty, we find a fractional frequency difference $y(\mathrm{PTB})-y(\mathrm{NPL})$ of $-1.3(1.2)\times 10^{-15}$ for a total measurement time of 67 h. This result is consistent with an agreement of both optical clocks and with recent absolute frequency measurements against caesium fountain clocks.
△ Less
Submitted 15 July, 2015;
originally announced July 2015.
-
Phase Analysis for Frequency Standards in the Microwave and Optical Domains
Authors:
M. Kazda,
V. Gerginov,
N. Huntemann,
B. Lipphardt,
S. Weyers
Abstract:
Coherent manipulation of atomic states is a key concept in high-precision spectroscopy and used in atomic fountain clocks and a number of optical frequency standards. Operation of these standards can involve a number of cyclic switching processes, which may induce cycle synchronous phase excursions of the interrogation signal and thus lead to shifts in the output of the frequency standard. We have…
▽ More
Coherent manipulation of atomic states is a key concept in high-precision spectroscopy and used in atomic fountain clocks and a number of optical frequency standards. Operation of these standards can involve a number of cyclic switching processes, which may induce cycle synchronous phase excursions of the interrogation signal and thus lead to shifts in the output of the frequency standard. We have built a FPGA-based phase analyzer to investigate these effects and conducted measurements on two frequency standards. For the caesium fountain PTB-CSF2 we were able to exclude phase variations of the microwave source at the level of a few $μ$rad, corresponding to relative frequency shifts of less than 10$^{-16}$. In the optical domain, we investigated phase variations in PTB's Yb$^+$ optical frequency standard and made detailed measurements of AOM chirps and their scaling with duty cycle and driving power. We ascertained that cycle-synchronous as well as long-term phase excursion do not cause frequency shifts larger than 10$^{-18}$.
△ Less
Submitted 9 July, 2015;
originally announced July 2015.
-
Improved limit on a temporal variation of $m_p/m_e$ from comparisons of Yb$^+$ and Cs atomic clocks
Authors:
N. Huntemann,
B. Lipphardt,
Chr. Tamm,
V. Gerginov,
S. Weyers,
E. Peik
Abstract:
Accurate measurements of different transition frequencies between atomic levels of the electronic and hyperfine structure over time are used to investigate temporal variations of the fine structure constant $α$ and the proton-to-electron mass ratio $μ$. We measure the frequency of the $^2S_{1/2}\rightarrow {^2F_{7/2}}$ electric octupole (E3) transition in $^{171}$Yb$^+$ against two caesium fountai…
▽ More
Accurate measurements of different transition frequencies between atomic levels of the electronic and hyperfine structure over time are used to investigate temporal variations of the fine structure constant $α$ and the proton-to-electron mass ratio $μ$. We measure the frequency of the $^2S_{1/2}\rightarrow {^2F_{7/2}}$ electric octupole (E3) transition in $^{171}$Yb$^+$ against two caesium fountain clocks as $f(E3) = 642\,121\,496\,772\,645.36(25)$~Hz with an improved fractional uncertainty of $3.9\times 10^{-16}$. This transition frequency shows a strong sensitivity to changes of $α$. Together with a number of previous and recent measurements of the $^2S_{1/2}\rightarrow {^2D_{3/2}}$ electric quadrupole transition in $^{171}$Yb$^+$ and with data from other elements, a least-squares analysis yields $(1/α)(dα/dt)=-0.20(20)\times 10^{-16}/\mathrm{yr}$ and $(1/μ)(dμ/dt)=-0.5(1.6)\times 10^{-16}/\mathrm{yr}$, confirming a previous limit on $dα/dt$ and providing the most stringent limit on $d μ/dt$ from laboratory experiments.
△ Less
Submitted 16 July, 2014;
originally announced July 2014.
-
Submesoscale dispersion in the vicinity of the Deepwater Horizon spill
Authors:
Andrew C. Poje,
Tamay M. Özgökmen,
Bruce Lipphardt, Jr.,
Brian K. Haus,
Edward H. Ryan,
Angelique C. Haza,
A. J. H. M. Reniers,
Josefina Olascoaga,
Guillaume Novelli,
Francisco J. Beron-Vera,
Shuyi Chen,
Arthur J. Mariano,
Gregg Jacobs,
Pat Hogan,
Emanuel Coelho,
A. D. Kirwan, Jr.,
Helga Huntley,
Annalisa Griffa
Abstract:
Reliable forecasts for the dispersion of oceanic contamination are important for coastal ecosystems, society and the economy as evidenced by the Deepwater Horizon oil spill in the Gulf of Mexico in 2010 and the Fukushima nuclear plant incident in the Pacific Ocean in 2011. Accurate prediction of pollutant pathways and concentrations at the ocean surface requires understanding ocean dynamics over a…
▽ More
Reliable forecasts for the dispersion of oceanic contamination are important for coastal ecosystems, society and the economy as evidenced by the Deepwater Horizon oil spill in the Gulf of Mexico in 2010 and the Fukushima nuclear plant incident in the Pacific Ocean in 2011. Accurate prediction of pollutant pathways and concentrations at the ocean surface requires understanding ocean dynamics over a broad range of spatial scales. Fundamental questions concerning the structure of the velocity field at the submesoscales (100 meters to tens of kilometers, hours to days) remain unresolved due to a lack of synoptic measurements at these scales. \textcolor{black} {Using high-frequency position data provided by the near-simultaneous release of hundreds of accurately tracked surface drifters, we study the structure of submesoscale surface velocity fluctuations in the Northern Gulf Mexico. Observed two-point statistics confirm the accuracy of classic turbulence scaling laws at 200m$-$50km scales and clearly indicate that dispersion at the submesoscales is \textit{local}, driven predominantly by energetic submesoscale fluctuations.} The results demonstrate the feasibility and utility of deploying large clusters of drifting instruments to provide synoptic observations of spatial variability of the ocean surface velocity field. Our findings allow quantification of the submesoscale-driven dispersion missing in current operational circulation models and satellite altimeter-derived velocity fields.
△ Less
Submitted 18 July, 2014; v1 submitted 11 July, 2014;
originally announced July 2014.
-
Direct comparison of optical lattice clocks with an intercontinental baseline of 9 000 km
Authors:
H. Hachisu,
M. Fujieda,
S. Nagano,
T. Gotoh,
A. Nogami,
T. Ido,
St. Falke,
N. Huntemann,
C. Grebing,
B. Lipphardt,
Ch. Lisdat,
D. Piester
Abstract:
We have demonstrated a direct frequency comparison between two $^{87}{\rm Sr}$ lattice clocks operated in intercontinentally separated laboratories in real time. Two-way satellite time and frequency transfer technique based on the carrier phase was employed for a direct comparison with a baseline of 9 000 km between Japan and Germany. A clock comparison was achieved for 83 640 s resulting in a fra…
▽ More
We have demonstrated a direct frequency comparison between two $^{87}{\rm Sr}$ lattice clocks operated in intercontinentally separated laboratories in real time. Two-way satellite time and frequency transfer technique based on the carrier phase was employed for a direct comparison with a baseline of 9 000 km between Japan and Germany. A clock comparison was achieved for 83 640 s resulting in a fractional difference of $(1.1\pm1.6) \times 10^{-15}$, where the statistical part is the biggest contribution to the uncertainty. This measurement directly confirms the agreement of the two optical clocks on an intercontinental scale.
△ Less
Submitted 12 July, 2014; v1 submitted 25 March, 2014;
originally announced March 2014.
-
A strontium lattice clock with $3 \times 10^{-17}$ inaccuracy and its frequency
Authors:
Stephan Falke,
Nathan Lemke,
Christian Grebing,
Burghard Lipphardt,
Stefan Weyers,
Vladislav Gerginov,
Nils Huntemann,
Christian Hagemann,
Ali Al-Masoudi,
Sebastian Häfner,
Stefan Vogt,
Uwe Sterr,
Christian Lisdat
Abstract:
We have measured the absolute frequency of the optical lattice clock based on $^{87}$Sr at PTB with an uncertainty of $3.9\times 10^{-16}$ using two caesium fountain clocks. This is close to the accuracy of today's best realizations of the SI second. The absolute frequency of the 5s$^2$ $^1$S$_0$-5s5p $^3$P$_0$ transition in $^{87}$Sr is 429,228,004,229,873.13(17) Hz. Our result is in excellent ag…
▽ More
We have measured the absolute frequency of the optical lattice clock based on $^{87}$Sr at PTB with an uncertainty of $3.9\times 10^{-16}$ using two caesium fountain clocks. This is close to the accuracy of today's best realizations of the SI second. The absolute frequency of the 5s$^2$ $^1$S$_0$-5s5p $^3$P$_0$ transition in $^{87}$Sr is 429,228,004,229,873.13(17) Hz. Our result is in excellent agreement with recent measurements performed in different laboratories worldwide. We improved the total systematic uncertainty of our Sr frequency standard by a factor of five and reach $3\times 10^{-17}$, opening new prospects for frequency ratio measurements between optical clocks for fundamental research, geodesy, or optical clock evaluation.
△ Less
Submitted 15 August, 2014; v1 submitted 12 December, 2013;
originally announced December 2013.
-
A Cs-Based Optical Frequency Measurement Using Cross-Linked Optical and Microwave Oscillators
Authors:
Chr. Tamm,
N. Huntemann,
B. Lipphardt,
V. Gerginov,
N. Nemitz,
M. Kazda,
S. Weyers,
E. Peik
Abstract:
We describe a measurement of the frequency of the 2S1/2(F = 0) - 2D3/2(F' = 2) transition of 171Yb+ at the wavelength 436 nm (frequency 688 THz), using a single Yb+ ion confined in a Paul trap and two caesium fountains as references. In one of the fountains, the frequency of the microwave oscillator that interrogates the caesium atoms is stabilized by the laser that excites the Yb+ reference trans…
▽ More
We describe a measurement of the frequency of the 2S1/2(F = 0) - 2D3/2(F' = 2) transition of 171Yb+ at the wavelength 436 nm (frequency 688 THz), using a single Yb+ ion confined in a Paul trap and two caesium fountains as references. In one of the fountains, the frequency of the microwave oscillator that interrogates the caesium atoms is stabilized by the laser that excites the Yb+ reference transition with a linewidth in the hertz range. The stability is transferred to the microwave oscillator with the use of a fiber laser based optical frequency comb generator that also provides the frequency conversion for the absolute frequency measurement. The frequency comb generator is configured as a transfer oscillator so that fluctuations of the pulse repetition rate and of the carrier offset frequency do not degrade the stability of the frequency conversion. The phase noise level of the generated ultrastable microwave signal is comparable to that of a cryogenic sapphire oscillator. For fountain operation with optical molasses loaded from a laser cooled atomic beam source, we obtain a stability corresponding to a fractional Allan deviation of $4.1\times 10^{-14}\ (τ/\text{s})^{-1/2}$. With the molasses loaded from thermal vapor and an averaging time of 65 h, we measure the frequency of the Yb+ transition with a relative statistical uncertainty of $2.8\times10^{-16}$ and a systematic uncertainty of $5.9\times10^{-16}$. The frequency was also simultaneously measured with the second fountain that uses a quartz-based interrogation oscillator. The unperturbed frequency of the Yb+ transition is realized with an uncertainty of $1.1\times10^{-16}$ that mainly results from the uncertainty of the blackbody shift at the operating temperature near 300 K. The transition frequency of 688 358 979 309 307.82(36) Hz, measured with the two fountains, is in good agreement with previous results.
△ Less
Submitted 30 October, 2013;
originally announced October 2013.
-
A generalized Ramsey excitation scheme with suppressed light shift
Authors:
N. Huntemann,
B. Lipphardt,
M. Okhapkin,
Chr. Tamm,
E. Peik,
A. V. Taichenachev,
V. I. Yudin
Abstract:
We experimentally investigate a recently proposed optical excitation scheme [V.I. Yudin et al., Phys. Rev. A 82, 011804(R)(2010)] that is a generalization of Ramsey's method of separated oscillatory fields and consists of a sequence of three excitation pulses. The pulse sequence is tailored to produce a resonance signal which is immune to the light shift and other shifts of the transition frequenc…
▽ More
We experimentally investigate a recently proposed optical excitation scheme [V.I. Yudin et al., Phys. Rev. A 82, 011804(R)(2010)] that is a generalization of Ramsey's method of separated oscillatory fields and consists of a sequence of three excitation pulses. The pulse sequence is tailored to produce a resonance signal which is immune to the light shift and other shifts of the transition frequency that are correlated with the interaction with the probe field. We investigate the scheme using a single trapped 171Yb+ ion and excite the highly forbidden 2S1/2-2F7/2 electric-octupole transition under conditions where the light shift is much larger than the excitation linewidth, which is in the Hertz range. The experiments demonstrate a suppression of the light shift by four orders of magnitude and an immunity against its fluctuations.
△ Less
Submitted 26 November, 2012; v1 submitted 10 September, 2012;
originally announced September 2012.
-
High-accuracy optical clock based on the octupole transition in 171Yb+
Authors:
N. Huntemann,
M. Okhapkin,
B. Lipphardt,
S. Weyers,
Chr. Tamm,
E. Peik
Abstract:
We experimentally investigate an optical frequency standard based on the 467 nm (642 THz) electric-octupole reference transition 2S1/2(F=0) -> F7/2(F=3) in a single trapped 171Yb+ ion. The extraordinary features of this transition result from the long natural lifetime and from the 4f136s2 configuration of the upper state. The electric quadrupole moment of the 2F7/2 state is measured as -0.041(5) e…
▽ More
We experimentally investigate an optical frequency standard based on the 467 nm (642 THz) electric-octupole reference transition 2S1/2(F=0) -> F7/2(F=3) in a single trapped 171Yb+ ion. The extraordinary features of this transition result from the long natural lifetime and from the 4f136s2 configuration of the upper state. The electric quadrupole moment of the 2F7/2 state is measured as -0.041(5) e(a0)^2, where e is the elementary charge and a0 the Bohr radius. We also obtain information on the differential scalar and tensorial components of the static polarizability and of the probe light induced ac Stark shift of the octupole transition. With a real-time extrapolation scheme that eliminates this shift, the unperturbed transition frequency is realized with a fractional uncertainty of 7.1x10^(-17). The frequency is measured as 642 121 496 772 645.15(52) Hz.
△ Less
Submitted 1 March, 2012; v1 submitted 10 November, 2011;
originally announced November 2011.
-
The 87-Sr optical frequency standard at PTB
Authors:
St. Falke,
H. Schnatz,
J. S. R. Vellore Winfred,
Th. Middelmann,
St. Vogt,
S. Weyers,
B. Lipphardt,
G. Grosche,
F. Riehle,
U. Sterr,
Ch. Lisdat
Abstract:
With 87-Sr atoms confined in a one dimensional optical lattice, the frequency of the optical clock transition 5s^2 ^1S_0 - 5s5p ^3P_0 has been determined to be 429 228 004 229 872.9(5) Hz. The transition frequency was measured with the help of a fs-frequency comb against one of PTB's H-masers whose frequency was measured simultaneously by the PTB Cs fountain clock CSF1. The Sr optical frequency st…
▽ More
With 87-Sr atoms confined in a one dimensional optical lattice, the frequency of the optical clock transition 5s^2 ^1S_0 - 5s5p ^3P_0 has been determined to be 429 228 004 229 872.9(5) Hz. The transition frequency was measured with the help of a fs-frequency comb against one of PTB's H-masers whose frequency was measured simultaneously by the PTB Cs fountain clock CSF1. The Sr optical frequency standard contributes with a fractional uncertainty of 1.5 10^-16 to the total uncertainty. The agreement of the measured transition frequency with previous measurements at other institutes supports the status of this transition as secondary representation of the second with the currently smallest uncertainty.
△ Less
Submitted 26 August, 2011; v1 submitted 26 April, 2011;
originally announced April 2011.
-
Long-distance remote comparison of ultrastable optical frequencies with 1e-15 instability in fractions of a second
Authors:
Andre Pape,
Osama Terra,
Jan Friebe,
Matthias Riedmann,
Temmo Wübbena,
Ernst-Maria Rasel,
Katharina Predehl,
Thomas Legero,
Burghard Lipphardt,
Harald Schnatz,
Gesine Grosche
Abstract:
We demonstrate a fully optical, long-distance remote comparison of independent ultrastable optical frequencies reaching a short term stability that is superior to any reported remote comparison of optical frequencies. We use two ultrastable lasers, which are separated by a geographical distance of more than 50 km, and compare them via a 73 km long phase-stabilized fiber in a commercial telecommuni…
▽ More
We demonstrate a fully optical, long-distance remote comparison of independent ultrastable optical frequencies reaching a short term stability that is superior to any reported remote comparison of optical frequencies. We use two ultrastable lasers, which are separated by a geographical distance of more than 50 km, and compare them via a 73 km long phase-stabilized fiber in a commercial telecommunication network. The remote characterization spans more than one optical octave and reaches a fractional frequency instability between the independent ultrastable laser systems of 3e-15 in 0.1 s. The achieved performance at 100 ms represents an improvement by one order of magnitude to any previously reported remote comparison of optical frequencies and enables future remote dissemination of the stability of 100 mHz linewidth lasers within seconds.
△ Less
Submitted 17 September, 2010; v1 submitted 28 August, 2009;
originally announced August 2009.
-
Phase- coherent comparison of two optical frequency standards over 146 km using a telecommunication fiber link
Authors:
Osama Terra,
Gesine Grosche,
Katharina Predehl,
Ronald Holzwarth,
Thomas Legero,
Uwe Sterr,
Burghard Lipphardt,
Harald Schnatz
Abstract:
We have explored the performance of two "dark fibers" of a commercial telecommunication fiber link for a remote comparison of optical clocks. The two fibers, linking the Leibniz University of Hanover (LUH) with the Physi-kalisch-Technische Bundesanstalt (PTB) in Braunschweig, are connected in Hanover to form a total fiber length of 146 km. At PTB the performance of an optical frequency standard…
▽ More
We have explored the performance of two "dark fibers" of a commercial telecommunication fiber link for a remote comparison of optical clocks. The two fibers, linking the Leibniz University of Hanover (LUH) with the Physi-kalisch-Technische Bundesanstalt (PTB) in Braunschweig, are connected in Hanover to form a total fiber length of 146 km. At PTB the performance of an optical frequency standard operating at 456 THz was imprinted to a cw trans-fer laser at 194 THz, and its frequency was transmitted over the fiber. In order to detect and compensate phase noise related to the optical fiber link we have built a low-noise optical fiber interferometer and investigated noise sources that affect the overall performance of the optical link. The frequency stability at the remote end has been measured using the clock laser of PTB's Yb+ frequency standard operating at 344 THz. We show that the frequency of a frequency-stabilized fiber laser can be transmitted over a total fiber length of 146 km with a relative frequency uncertainty below 1E-19, and short term frequency instability given by the fractional Allan deviation of sy(t)=3.3E-15/(t/s).
△ Less
Submitted 18 June, 2009;
originally announced June 2009.
-
Optical frequency transfer via 146 km fiber link with 10^{-19} relative accuracy
Authors:
G. Grosche,
O. Terra,
K. Predehl,
R. Holzwarth,
B. Lipphardt,
F. Vogt,
U. Sterr,
H. Schnatz
Abstract:
We demonstrate the long-distance transmission of an ultra-stable optical frequency derived directly from a state-of-the-art optical frequency standard. Using an active stabilization system we deliver the frequency via a 146 km long underground fiber link with a fractional instability of 3*10^{-15} at 1 s, which is close to the theoretical limit for our transfer experiment. The relative uncertain…
▽ More
We demonstrate the long-distance transmission of an ultra-stable optical frequency derived directly from a state-of-the-art optical frequency standard. Using an active stabilization system we deliver the frequency via a 146 km long underground fiber link with a fractional instability of 3*10^{-15} at 1 s, which is close to the theoretical limit for our transfer experiment. The relative uncertainty for the transfer is below 1*10^{-19} after 30 000 seconds. Tests with a very short fiber show that noise in our stabilization system contributes fluctuations which are two orders of magnitude lower, namely 3*10^{-17} at 1 s, reaching 10^{-20} after 4000 s.
△ Less
Submitted 17 April, 2009;
originally announced April 2009.
-
Interrogation of caesium atoms in a fountain clock by a femtosecond laser microwave oscillator
Authors:
S. Weyers,
B. Lipphardt,
H. Schnatz
Abstract:
A caesium fountain clock is operated utilizing a microwave oscillator that derives its frequency stability from a stable laser by means of a fiber-laser femtosecond frequency comb. This oscillator is based on the technology developed for optical clocks and replaces the quartz based microwave oscillator commonly used in fountain clocks. As a result, a significant decrease of the frequency instabi…
▽ More
A caesium fountain clock is operated utilizing a microwave oscillator that derives its frequency stability from a stable laser by means of a fiber-laser femtosecond frequency comb. This oscillator is based on the technology developed for optical clocks and replaces the quartz based microwave oscillator commonly used in fountain clocks. As a result, a significant decrease of the frequency instability of the fountain clock is obtained, reaching 0.74E-14 at 100 s averaging time. We could demonstrate that for a significant range of detected atom numbers the instability is limited by quantum projection noise only, and that for the current status of this fountain clock the new microwave source poses no limit on the achievable frequency instability.
△ Less
Submitted 19 January, 2009;
originally announced January 2009.
-
Measurement noise floor for a long-distance optical carrier transmission via fiber
Authors:
G. Grosche,
O. Terra,
K. Predehl,
T. Haensch,
R. Holzwarth,
B. Lipphardt,
F. Vogt,
U. Sterr,
H. Schnatz
Abstract:
We investigated the measurement floor and link stability for the transfer of an ultra-stable optical frequency via an optical fiber link. We achieved a near-delay-limited instability of 3x10^(-15)/(tau x Hz) for 147 km deployed fiber, and 10^(-20) (integrations time tau = 4000 s) for the noise floor.
We investigated the measurement floor and link stability for the transfer of an ultra-stable optical frequency via an optical fiber link. We achieved a near-delay-limited instability of 3x10^(-15)/(tau x Hz) for 147 km deployed fiber, and 10^(-20) (integrations time tau = 4000 s) for the noise floor.
△ Less
Submitted 1 December, 2008;
originally announced December 2008.
-
Optical frequency synthesis and measurement using fibre-based femtosecond lasers
Authors:
Gesine Grosche,
Burghard Lipphardt,
Harald Schnatz
Abstract:
We report the synthesis and measurement of an ultra-precise and extremely stable optical frequency in the telecommunications window around 1543 nm. Using a fibre-based femtosecond frequency comb we have phase-stabilised a fibre laser at 194 THz to an optical frequency standard at 344 THz, thus transferring the properties of the optical frequency standard to another spectral region. Relative to t…
▽ More
We report the synthesis and measurement of an ultra-precise and extremely stable optical frequency in the telecommunications window around 1543 nm. Using a fibre-based femtosecond frequency comb we have phase-stabilised a fibre laser at 194 THz to an optical frequency standard at 344 THz, thus transferring the properties of the optical frequency standard to another spectral region. Relative to the optical frequency standard, the synthesised frequency at 194 THz is determined to within 1 mHz and its fractional frequency instability is measured to be less than 2*10^{-15} at 1 s, reaching 5*10^{-18} after 8000 s. We also measured the synthesised frequency against a caesium fountain clock: here the frequency comparison itself contributes less than 4 mHz (2*10^{-17}) to the uncertainty. Our results confirm the suitability of fibre based frequency comb technology for precision measurements and frequency synthesis, and enable long-distance comparison of optical clocks by using optical fibres to transmit the frequency information.
△ Less
Submitted 19 September, 2008;
originally announced September 2008.
-
The stability of an optical clock laser transferred to the interrogation oscillator for a Cs fountain
Authors:
B. Lipphardt,
G. Grosche,
U. Sterr,
Chr. Tamm,
S. Weyers,
H. Schnatz
Abstract:
We stabilise a microwave oscillator at 9.6 GHz to an optical clock laser at 344 THz by using a fibre-based femtosecond laser frequency comb as a transfer oscillator. With a second frequency comb we measure independently the instability of the microwave source with respect to another optical clock laser frequency at 456 THz. The total fractional frequency instability of this optic-to-microwave an…
▽ More
We stabilise a microwave oscillator at 9.6 GHz to an optical clock laser at 344 THz by using a fibre-based femtosecond laser frequency comb as a transfer oscillator. With a second frequency comb we measure independently the instability of the microwave source with respect to another optical clock laser frequency at 456 THz. The total fractional frequency instability of this optic-to-microwave and microwave-to-optic conversion resulted in an Allan deviation sigma_y, of sigma_y=1.2E-14 at 1 s averaging time (band width 50 kHz). The residual phase noise density is -97 dBc/Hz at 10 Hz offset from the 9.6 GHz carrier. Replacing the existing quartz-based interrogation oscillator of the PTB caesium fountain CSF1 with this optically stabilised microwave source will reduce the instability contribution due to the Dick effect from the 1E-13-level at 1s averaging time to an insignificant level at the current status of CSF1. Therefore this new microwave source can be an alternative to cryogenic sapphire-loaded cavity oscillators in order to overcome the limitations of state-of-the-art quartz oscillators.
△ Less
Submitted 12 September, 2008;
originally announced September 2008.
-
Absolute frequency measurement of the magnesium intercombination transition $^1S_0 \to ^3P_1$
Authors:
Jan Friebe,
André Pape,
Matthias Riedmann,
Karsten Moldenhauer,
Tanja Mehlstäubler,
Nils Rehbein,
Christian Lisdat,
Ernst M. Rasel,
Wolfgang Ertmer,
Harald Schnatz,
Burghard Lipphardt,
Gesine Grosche
Abstract:
We report on a frequency measurement of the $(3s^2)^1S_0\to(3s3p)^3P_1$ clock transition of $^{24}$Mg on a thermal atomic beam. The intercombination transition has been referenced to a portable primary Cs frequency standard with the help of a femtosecond fiber laser frequency comb. The achieved uncertainty is $2.5\times10^{-12}$ which corresponds to an increase in accuracy of six orders of magni…
▽ More
We report on a frequency measurement of the $(3s^2)^1S_0\to(3s3p)^3P_1$ clock transition of $^{24}$Mg on a thermal atomic beam. The intercombination transition has been referenced to a portable primary Cs frequency standard with the help of a femtosecond fiber laser frequency comb. The achieved uncertainty is $2.5\times10^{-12}$ which corresponds to an increase in accuracy of six orders of magnitude compared to previous results. The measured frequency value permits the calculation of several other optical transitions from $^1S_0$ to the $^3P_J$-level system for $^{24}$Mg, $^{25}$Mg and $^{26}$Mg. We describe in detail the components of our optical frequency standard like the stabilized spectroscopy laser, the atomic beam apparatus used for Ramsey-Bordé interferometry and the frequency comb generator and discuss the uncertainty contributions to our measurement including the first and second order Doppler effect. An upper limit of $3\times10^{-13}$ in one second for the short term instability of our optical frequency standard was determined by comparison with a GPS disciplined quartz oscillator.
△ Less
Submitted 30 November, 2007;
originally announced November 2007.
-
An Optical Lattice Clock with Spin-polarized 87Sr Atoms
Authors:
Xavier Baillard,
Mathilde Fouché,
Rodolphe Le Targat,
Philip G. Westergaard,
Arnaud Lecallier,
Frédéric Chapelet,
Michel Abgrall,
Giovanni D. Rovera,
Philippe Laurent,
Peter Rosenbusch,
Sébastien Bize,
Giorgio Santarelli,
André Clairon,
Pierre Lemonde,
Gesine Grosche,
Burghard Lipphardt,
Harald Schnatz
Abstract:
We present a new evaluation of an 87Sr optical lattice clock using spin polarized atoms. The frequency of the 1S0-3P0 clock transition is found to be 429 228 004 229 873.6 Hz with a fractional accuracy of 2.6 10^{-15}, a value that is comparable to the frequency difference between the various primary standards throughout the world. This measurement is in excellent agreement with a previous one o…
▽ More
We present a new evaluation of an 87Sr optical lattice clock using spin polarized atoms. The frequency of the 1S0-3P0 clock transition is found to be 429 228 004 229 873.6 Hz with a fractional accuracy of 2.6 10^{-15}, a value that is comparable to the frequency difference between the various primary standards throughout the world. This measurement is in excellent agreement with a previous one of similar accuracy.
△ Less
Submitted 29 September, 2007;
originally announced October 2007.
-
Laboratory Limits on Temporal Variations of Fundamental Constants: An Update
Authors:
E. Peik,
B. Lipphardt,
H. Schnatz,
Chr. Tamm,
S. Weyers,
R. Wynands
Abstract:
Precision comparisons of different atomic frequency standards over a period of a few years can be used for a sensitive search for temporal variations of fundamental constants. We present recent frequency measurements of the 688 THz transition in the $^{171}$Yb$^+$ ion. For this transition frequency a record over six years is now available, showing that a possible frequency drift relative to a ce…
▽ More
Precision comparisons of different atomic frequency standards over a period of a few years can be used for a sensitive search for temporal variations of fundamental constants. We present recent frequency measurements of the 688 THz transition in the $^{171}$Yb$^+$ ion. For this transition frequency a record over six years is now available, showing that a possible frequency drift relative to a cesium clock can be constrained to $(-0.54\pm0.97)$ Hz/yr, i.e. at the level of $2\cdot10^{-15}$ per year. Combined with precision frequency measurements of an optical frequency in $^{199}$Hg$^+$ and of the hyperfine ground state splitting in $^{87}$Rb a stringent limit on temporal variations of the fine structure constant $α$: $d\lnα/dt= (-0.26\pm0.39)\cdot 10^{-15} {\rm yr}^{-1}$ and a model-dependent limit for variations of the proton-to-electron mass ratio $μ$ in the present epoch can be derived: $d \ln μ/dt = (-1.2 \pm 2.2)\cdot 10^{-15} {\rm yr}^{-1}$. We discuss these results in the context of astrophysical observations that apparently indicate changes in both of these constants over the last 5--10 billion years.
△ Less
Submitted 9 November, 2006;
originally announced November 2006.
-
Frequency comparisons and absolute frequency measurements of 171Yb+ single-ion optical frequency standards
Authors:
E. Peik,
B. Lipphardt,
H. Schnatz,
T. Schneider,
Chr. Tamm,
S. G. Karshenboim
Abstract:
We describe experiments with an optical frequency standard based on a laser cooled $^{171}$Yb$^+$ ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the $^2S_{1/2}(F=0)$ ground state to the $^2D_{3/2}(F=2)$ state at the wavelength of 436 nm is used as the reference transition. In order to compare two $^{171}$Yb$^+$ standards, separate frequency servo systems are…
▽ More
We describe experiments with an optical frequency standard based on a laser cooled $^{171}$Yb$^+$ ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the $^2S_{1/2}(F=0)$ ground state to the $^2D_{3/2}(F=2)$ state at the wavelength of 436 nm is used as the reference transition. In order to compare two $^{171}$Yb$^+$ standards, separate frequency servo systems are employed to stabilize two probe laser frequencies to the reference transition line centers of two independently stored ions. The experimental results indicate a relative instability (Allan standard deviation) of the optical frequency difference between the two systems of $σ_y(1000 {\rm s})=5\cdot 10^{-16}$ only, so that shifts in the sub-hertz range can be resolved. Shifts of several hertz are observed if a stationary electric field gradient is superimposed on the radiofrequency trap field. The absolute optical transition frequency of Yb$^+$ at 688 THz was measured with a cesium atomic clock at two times separated by 2.8 years. A temporal variation of this frequency can be excluded within a $1σ$ relative uncertainty of $4.4\cdot 10^{-15}$ yr$^{-1}$. Combined with recently published values for the constancy of other transition frequencies this measurement provides a limit on the present variability of the fine structure constant $α$ at the level of $2.0\cdot 10^{-15}$ yr$^{-1}$.
△ Less
Submitted 14 April, 2005;
originally announced April 2005.
-
New limit on the present temporal variation of the fine structure constant
Authors:
E. Peik,
B. Lipphardt,
H. Schnatz,
T. Schneider,
Chr. Tamm,
S. G. Karshenboim
Abstract:
The comparison of different atomic transition frequencies over time can be used to determine the present value of the temporal derivative of the fine structure constant alpha in a model-independent way without assumptions on constancy or variability of other parameters. We have measured an optical transition frequency at 688 THz in ^{171}Yb+ with a cesium atomic clock at two times separated by 2…
▽ More
The comparison of different atomic transition frequencies over time can be used to determine the present value of the temporal derivative of the fine structure constant alpha in a model-independent way without assumptions on constancy or variability of other parameters. We have measured an optical transition frequency at 688 THz in ^{171}Yb+ with a cesium atomic clock at two times separated by 2.8 years and find a value for the fractional variation of the frequency ratio $f_{\rm Yb}/f_{\rm Cs}$ of $(-1.2\pm 4.4)\cdot 10^{-15}$ yr$^{-1}$, consistent with zero. Combined with recently published values for the constancy of other transition frequencies this measurement sets an upper limit on the present variability of alpha at the level of $2.0\cdot 10^{-15}$ yr$^{-1}$, corresponding so far to the most stringent limit from laboratory experiments.
△ Less
Submitted 28 October, 2004; v1 submitted 27 February, 2004;
originally announced February 2004.
-
Kerr-lens mode-locked lasers as transfer oscillators for optical frequency measurements
Authors:
Harald R. Telle,
Burghard Lipphardt,
Jörn Stenger
Abstract:
We introduce a novel concept for optical frequency measurement and division which employs a Kerr-lens mode-locked laser as a transfer oscillator whose noise properties do not enter the measurement process. We experimentally demonstrate, that this method opens up the route to phase-link signals with arbitrary frequencies in the optical or microwave range while their frequency stability is preserv…
▽ More
We introduce a novel concept for optical frequency measurement and division which employs a Kerr-lens mode-locked laser as a transfer oscillator whose noise properties do not enter the measurement process. We experimentally demonstrate, that this method opens up the route to phase-link signals with arbitrary frequencies in the optical or microwave range while their frequency stability is preserved.
△ Less
Submitted 17 July, 2001;
originally announced July 2001.