Visible-Light High-Contrast Imaging and Polarimetry with SCExAO/VAMPIRES
Authors:
Miles Lucas,
Barnaby Norris,
Olivier Guyon,
Michael Bottom,
Vincent Deo,
Sébastian Vievard,
Julien Lozi,
Kyohoon Ahn,
Jaren Ashcraft,
Thayne Currie,
David Doelman,
Tomoyuki Kudo,
Lucie Leboulleux,
Lucinda Lilley,
Maxwell Millar-Blanchaer,
Boris Safonov,
Peter Tuthill,
Taichi Uyama,
Aidan Walk,
Manxuan Zhang
Abstract:
We present significant upgrades to the VAMPIRES instrument, a visible-light (600 nm to 800 nm) high-contrast imaging polarimeter integrated within SCExAO on the Subaru telescope. Key enhancements include new qCMOS detectors, coronagraphs, polarization optics, and a multiband imaging mode, improving sensitivity, resolution, and efficiency. These upgrades position VAMPIRES as a powerful tool for stu…
▽ More
We present significant upgrades to the VAMPIRES instrument, a visible-light (600 nm to 800 nm) high-contrast imaging polarimeter integrated within SCExAO on the Subaru telescope. Key enhancements include new qCMOS detectors, coronagraphs, polarization optics, and a multiband imaging mode, improving sensitivity, resolution, and efficiency. These upgrades position VAMPIRES as a powerful tool for studying sub-stellar companions, accreting protoplanets, circumstellar disks, stellar jets, stellar mass-loss shells, and solar system objects. The instrument achieves angular resolutions from 17 mas to 21 mas and Strehl ratios up to 60\%, with 5$σ$ contrast limits of $10^{\text{-}4}$ at 0.1'' to $10^{\text{-}6}$ beyond 0.5''. We demonstrate these capabilities through spectro-polarimetric coronagraphic imaging of the HD 169142 circumstellar disk, ADI+SDI imaging of the sub-stellar companion HD 1160B, narrowband H$α$ imaging of the R Aqr emission nebula, and spectro-polarimetric imaging of Neptune.
△ Less
Submitted 15 October, 2024;
originally announced October 2024.
Measurement of Ac227 Impurity in Ac225 using Decay Energy Spectroscopy
Authors:
Aidan D. Tollefson,
Chandler M. Smith,
Matthew H. Carpenter,
Mark P. Croce,
Michael E. Fassbender,
Katrina E. Koehler,
Laura M. Lilley,
Ellen M. O'Brien,
Daniel R. Schmidt,
Benjamin W. Stein,
Joel N. Ullom,
Michael D. Yoho,
David J. Mercer
Abstract:
225Ac is a valuable medical radionuclide for targeted alpha therapy, but 227Ac is an undesirable byproduct of an accelerator-based synthesis method under investigation. Sufficient detector sensitivity is critical for quantifying the trace impurity of 227Ac, with the 227Ac/225Ac activity ratio predicted to be approximately 0.15% by end-of-bombardment (EOB). Superconducting transition edge sensor (T…
▽ More
225Ac is a valuable medical radionuclide for targeted alpha therapy, but 227Ac is an undesirable byproduct of an accelerator-based synthesis method under investigation. Sufficient detector sensitivity is critical for quantifying the trace impurity of 227Ac, with the 227Ac/225Ac activity ratio predicted to be approximately 0.15% by end-of-bombardment (EOB). Superconducting transition edge sensor (TES) microcalorimeters offer high resolution energy spectroscopy using the normal-to-superconducting phase transition to measure small change in temperature. By embedding 225Ac production samples in a gold foil thermally coupled to a TES microcalorimeter we can measure the decay energies of the radionuclides embedded with high resolution and efficiency. This technique, known as decay energy spectroscopy (DES), collapses several peaks from alpha decays into single Q-value peaks. In practice there are more complex factors in the interpretation of data using DES, which we will discuss herein. Using this technique we measured the EOB 227Ac impurity to be (0.142 +/- 0.005)% for a single production sample. This demonstration has shown that DES can distinguish closely related isotopic features and is a useful tool for quantitative measures.
△ Less
Submitted 3 February, 2021;
originally announced February 2021.