The Digital Motion Control System for the Submillimeter Array Antennas
Authors:
T. R. Hunter,
R. W. Wilson,
R. Kimberk,
P. S. Leiker,
N. A. Patel,
R. Blundell,
R. D. Christensen,
A. R. Diven,
J. Maute,
R. J. Plante,
P. Riddle,
K. H. Young
Abstract:
We describe the design and performance of the digital servo and motion control system for the 6-meter diameter parabolic antennas of the Submillimeter Array (SMA) on Mauna Kea, Hawaii. The system is divided into three nested layers operating at a different, appropriate bandwidth. (1) A rack-mounted, real-time Unix system runs the position loop which reads the high resolution azimuth and elevation…
▽ More
We describe the design and performance of the digital servo and motion control system for the 6-meter diameter parabolic antennas of the Submillimeter Array (SMA) on Mauna Kea, Hawaii. The system is divided into three nested layers operating at a different, appropriate bandwidth. (1) A rack-mounted, real-time Unix system runs the position loop which reads the high resolution azimuth and elevation encoders and sends velocity and acceleration commands at 100 Hz to a custom-designed servo control board (SCB). (2) The microcontroller-based SCB reads the motor axis tachometers and implements the velocity loop by sending torque commands to the motor amplifiers at 558 Hz. (3) The motor amplifiers implement the torque loop by monitoring and sending current to the three-phase brushless drive motors at 20 kHz. The velocity loop uses a traditional proportional-integral-derivative (PID) control algorithm, while the position loop uses only a proportional term and implements a command shaper based on the Gauss error function. Calibration factors and software filters are applied to the tachometer feedback prior to the application of the servo gains in the torque computations. All of these parameters are remotely adjustable in software. The three layers of the control system monitor each other and are capable of shutting down the system safely if a failure or anomaly occurs. The Unix system continuously relays antenna status to the central observatory computer via reflective memory. In each antenna, a Palm Vx hand controller displays system status and allows full local control of the drives in an intuitive touchscreen user interface. It can also be connected outside the cabin for convenience during antenna reconfigurations. Excellent tracking performance (0.3 arcsec rms) is achieved with this system. It has been in reliable operation on 8 antennas for over 10 years and has required minimal maintenance.
△ Less
Submitted 18 March, 2013;
originally announced March 2013.
-
A Multi-Baseline 12 GHz Atmospheric Phase Interferometer with One Micron Path Length Sensitivity
Authors:
Robert S. Kimberk,
Todd R. Hunter,
Patrick S. Leiker,
Raymond Blundell,
George U. Nystrom,
Glen R. Petitpas,
John Test,
Robert W. Wilson,
Paul Yamaguchi,
Kenneth H. Young
Abstract:
We have constructed a five station 12 GHz atmospheric phase interferometer (API) for the Submillimeter Array (SMA) located near the summit of Mauna Kea, Hawaii. Operating at the base of unoccupied SMA antenna pads, each station employs a commercial low noise mixing block coupled to a 0.7 m off-axis satellite dish which receives a broadband, white noise-like signal from a geostationary satellite. T…
▽ More
We have constructed a five station 12 GHz atmospheric phase interferometer (API) for the Submillimeter Array (SMA) located near the summit of Mauna Kea, Hawaii. Operating at the base of unoccupied SMA antenna pads, each station employs a commercial low noise mixing block coupled to a 0.7 m off-axis satellite dish which receives a broadband, white noise-like signal from a geostationary satellite. The signals are processed by an analog correlator to produce the phase delays between all pairs of stations with projected baselines ranging from 33 to 261 m. Each baseline's amplitude and phase is measured continuously at a rate of 8 kHz, processed, averaged and output at 10 Hz. Further signal processing and data reduction is accomplished with a Linux computer, including the removal of the diurnal motion of the target satellite. The placement of the stations below ground level with an environmental shield combined with the use of low temperature coefficient, buried fiber optic cables provides excellent system stability. The sensitivity in terms of rms path length is 1.3 microns which corresponds to phase deviations of about 1 degree of phase at the highest operating frequency of the SMA. The two primary data products are: (1) standard deviations of observed phase over various time scales, and (2) phase structure functions. These real-time statistical data measured by the API in the direction of the satellite provide an estimate of the phase front distortion experienced by the concurrent SMA astronomical observations. The API data also play an important role, along with the local opacity measurements and weather predictions, in helping to plan the scheduling of science observations on the telescope.
△ Less
Submitted 31 May, 2012;
originally announced June 2012.
-
Design and Performance of a Digital Phase Lock Loop for Gunn Oscillators
Authors:
Todd R. Hunter,
Robert Kimberk,
Patrick Steve Leiker,
Cheuk-Yu Edward Tong,
Robert W. Wilson
Abstract:
The digital phase lock loop described in this paper has been in use on the Submillimeter Array (SMA) front-end receivers for over a decade and has been a key element in obtaining all of the high quality images that have been published from this telescope over the years. The technical achievements enabled by these devices include the first phase closure observations in the 690 GHz band, the first a…
▽ More
The digital phase lock loop described in this paper has been in use on the Submillimeter Array (SMA) front-end receivers for over a decade and has been a key element in obtaining all of the high quality images that have been published from this telescope over the years. The technical achievements enabled by these devices include the first phase closure observations in the 690 GHz band, the first attempts at band-to-band phase transfer at submillimeter wavelengths, and the first successful demonstration of interferometry using a fully photonic millimeter-wave local oscillator. Copies of these devices are also in place at the Caltech Submillimeter Observatory and the James Clerk Maxwell Telescope in support of the eSMA project and submillimeter VLBI experiments. Additional units of this design were used by the Princeton Millimeter Interferometer and the Microwave Anisotropy Telescope. In total, over three dozen units have been constructed and used in astronomical studies. In this paper, we briefly describe the background theory, design, performance, and calibration steps, and provide useful testing and repair information.
△ Less
Submitted 7 January, 2011;
originally announced January 2011.
-
Gain Stabilization of a Submillimeter SIS Heterodyne Receiver
Authors:
James Battat,
Raymond Blundell,
Todd R. Hunter,
Robert Kimberk,
Patrick S. Leiker,
Cheuk-yu Edward Tong
Abstract:
We have designed a system to stabilize the gain of a submillimeter heterodyne receiver against thermal fluctuations of the mixing element. In the most sensitive heterodyne receivers, the mixer is usually cooled to 4 K using a closed-cycle cryocooler, which can introduce ~1% fluctuations in the physical temperature of the receiver components. We compensate for the resulting mixer conversion gain…
▽ More
We have designed a system to stabilize the gain of a submillimeter heterodyne receiver against thermal fluctuations of the mixing element. In the most sensitive heterodyne receivers, the mixer is usually cooled to 4 K using a closed-cycle cryocooler, which can introduce ~1% fluctuations in the physical temperature of the receiver components. We compensate for the resulting mixer conversion gain fluctuations by monitoring the physical temperature of the mixer and adjusting the gain of the intermediate frequency (IF) amplifier that immediately follows the mixer. This IF power stabilization scheme, developed for use at the Submillimeter Array (SMA), a submillimeter interferometer telescope on Mauna Kea in Hawaii, routinely achieves a receiver gain stability of 1 part in 6,000 (rms to mean). This is an order of magnitude improvement over the typical uncorrected stability of 1 part in a few hundred. Our gain stabilization scheme is a useful addition to SIS heterodyne receivers that are cooled using closed-cycle cryocoolers in which the 4 K temperature fluctuations tend to be the leading cause of IF power fluctuations.
△ Less
Submitted 2 October, 2007;
originally announced October 2007.
-
Receiver control for the Submillimeter Array
Authors:
T. R. Hunter,
R. W. Wilson,
R. Kimberk,
P. S. Leiker,
R. D. Christensen
Abstract:
Efficient operation of a submillimeter interferometer requires remote (preferably automated) control of mechanically tuned local oscillators, phase-lock loops, mixers, optics, calibration vanes and cryostats. The present control system for these aspects of the Submillimeter Array (SMA) will be described. Distributed processing forms the underlying architecture and the software is split between har…
▽ More
Efficient operation of a submillimeter interferometer requires remote (preferably automated) control of mechanically tuned local oscillators, phase-lock loops, mixers, optics, calibration vanes and cryostats. The present control system for these aspects of the Submillimeter Array (SMA) will be described. Distributed processing forms the underlying architecture and the software is split between hardware platforms in a leader/follower arrangement. In each antenna cabin, a serial network of up to ten independent 80C196 microcontroller boards attaches to the real-time PowerPC computer (running LynxOS). A multi-threaded, gcc-compiled leader program on the PowerPC accepts top-level requests via remote procedure calls (RPC), subsequently dispatches tuning commands to the relevant follower microcontrollers, and regularly reports the system status to optical-fiber-based reflective memory for common access by the telescope monitor and error reporting system. All serial communication occurs asynchronously via encoded, variable-length packets. The microcontrollers respond to the requested commands and queries by accessing non-volatile, rewriteable lookup-tables (when appropriate) and executing embedded software that operates additional electronic devices (DACs, ADCs, etc.). Since various receiver hardware components require linear or rotary motion, each microcontroller also implements a position servo via a one-millisecond interrupt service routine which drives a DC-motor/encoder combination that remains standard across each subsystem.
△ Less
Submitted 7 July, 2020; v1 submitted 26 September, 2005;