TSA-inspired micro tomosythesis scanner for rapid scouting of histopathology samples
Authors:
David T. Nguyen,
Thomas C. Larsen,
Muyang Wang,
Russel H. Knutsen,
Zhihong Yang,
Eric E. Bennett,
Dumitru Mazilu,
Zu-Xi Yu,
Xi Tao,
Danielle R. Donahue,
Ahmed Gharib,
Christopher K. E. Bleck,
Joel Moss,
Beth A. Kozel,
Alan T. Remaley,
Han Wen
Abstract:
In pathology protocols, each tissue block can generate a large number of sections making it impractical to analyze every section. X-ray microscopy that provides a rapid survey of intact tissue blocks can help pinpoint the relevant structures in 3D space for subsequent analysis, and thus reduce workload and enable further automation downstream. Unlike dedicated virtual histology studies by traditio…
▽ More
In pathology protocols, each tissue block can generate a large number of sections making it impractical to analyze every section. X-ray microscopy that provides a rapid survey of intact tissue blocks can help pinpoint the relevant structures in 3D space for subsequent analysis, and thus reduce workload and enable further automation downstream. Unlike dedicated virtual histology studies by traditional micro computed tomography (CT), routine scout imaging is constrained by a time window of minutes and minimal sample handling to avoid interfering with the pathology protocols. Traditional micro CT was not able to meet the requirements due to lengthy study times or sample alteration by the introduction of x-ray contrast agents. A form of x-ray tomosynthesis used in security screening was found to be efficient for rapid microscopy of unstained samples. When compared to a commercial micro CT scanner, it provided a 10-fold increase in imaging speed and a 4.8-fold increase in contrast-to-noise ratio. We report the results from a variety of human and animal tissue samples, where it served as an integral step of pathology protocols. In cases of vascular disease, it provided quantitative measurements of calcification in intact samples, which were difficult to obtain by standard pathology procedures. The prospect of continuous and automated screening of many samples in an assembly-line approach is discussed.
△ Less
Submitted 16 May, 2020;
originally announced May 2020.
Demonstration of sensitivity increase in mercury free-spin-precession magnetometers due to laser-based readout for neutron electric dipole moment searches
Authors:
G. Ban,
G. Bison,
K. Bodek,
M. Daum,
M. Fertl,
B. Franke,
Z. D. Grujić,
W. Heil,
M. Horras,
M. Kasprzak,
Y. Kermaidic,
K. Kirch,
H. -C. Koch,
S. Komposch,
A. Kozel,
J. Krempel,
B. Lauss,
T. Lefort,
A. Mtchedlishvili,
G. Pignol,
F. M. Piegsa,
P. Prashanth,
G. Quéméner,
M. Rawlik,
D. Rebreyend
, et al. (9 additional authors not shown)
Abstract:
We report on a laser based $^{199}$Hg co-magnetometer deployed in an experiment searching for a permanent electric dipole moment of the neutron. We demonstrate a more than five times increased signal to-noise-ratio in a direct comparison measurement with its $^{204}$Hg discharge bulb-based predecessor. An improved data model for the extraction of important system parameters such as the degrees of…
▽ More
We report on a laser based $^{199}$Hg co-magnetometer deployed in an experiment searching for a permanent electric dipole moment of the neutron. We demonstrate a more than five times increased signal to-noise-ratio in a direct comparison measurement with its $^{204}$Hg discharge bulb-based predecessor. An improved data model for the extraction of important system parameters such as the degrees of absorption and polarization is derived. Laser- and lamp-based data-sets can be consistently described by the improved model which permits to compare measurements using the two different light sources and to explain the increase in magnetometer performance. The laser-based magnetometer satisfies the magnetic field sensitivity requirements for the next generation nEDM experiments.
△ Less
Submitted 16 April, 2018;
originally announced April 2018.