-
Signal partitioning in superfluid ${}^4$He: a Monte Carlo approach
Authors:
Francesco Toschi,
Axel Brunold,
Lea Burmeister,
Klaus Eitel,
Christian Enss,
Eleanor Fascione,
Torben Ferber,
Rahel Gabriel,
Lena Hauswald,
Felix Kahlhoefer,
Sebastian Kempf,
Markus Klute,
Belina von Krosigk,
Sebastian Lindemann,
Benedikt Maier,
Marc Schumann,
Melih Solmaz,
Kathrin Valerius,
Friedrich Carl Wagner
Abstract:
Superfluid ${}^4$He is an ideal candidate for the direct detection of light dark matter via nuclear recoils thanks to its low nuclear mass and the possibility to reach a low detection energy threshold by exploiting the generated quasiparticles. The design of future detectors based on this target, such as the DELight experiment, requires a proper understanding of the formation and partitioning of t…
▽ More
Superfluid ${}^4$He is an ideal candidate for the direct detection of light dark matter via nuclear recoils thanks to its low nuclear mass and the possibility to reach a low detection energy threshold by exploiting the generated quasiparticles. The design of future detectors based on this target, such as the DELight experiment, requires a proper understanding of the formation and partitioning of the signal for different energy depositions from various sources. This work presents an overview of the physical processes involved in the energy deposition of recoiling electrons and ions, and describes a Monte Carlo approach to the partitioning of the signal into different channels. Despite an overall good agreement with existing literature, differences in the region of interest for light dark matter searches below 200\,eV are observed.
△ Less
Submitted 17 October, 2024;
originally announced October 2024.
-
Advanced fabrication process for particle absorbers of highly pure electroplated gold for microcalorimeter applications
Authors:
Michael Müller,
Ria-Helen Zühlke,
Sebastian Kempf
Abstract:
Magnetic microcalorimeters (MMCs) have become a key technology for applications requiring outstanding energy resolution, fast signal rise time and excellent linearity. MMCs measure the temperature rise upon absorption of a single particle within a particle absorber by using a paramagnetic temperature sensor that is thermally coupled to the absorber. The design and fabrication of the particle absor…
▽ More
Magnetic microcalorimeters (MMCs) have become a key technology for applications requiring outstanding energy resolution, fast signal rise time and excellent linearity. MMCs measure the temperature rise upon absorption of a single particle within a particle absorber by using a paramagnetic temperature sensor that is thermally coupled to the absorber. The design and fabrication of the particle absorber is key for excellent detector performance. Here, we present a microfabrication process for free-standing particle absorbers made of two stacked and independently electroplated high-purity Au layers. This enables, for example, embedding of radioactive sources within the absorber for realizing a 4$π$ detection geometry in radionuclide metrology or preparing detector arrays with variable quantum efficiency and energy resolution as requested for future applications in high energy physics. Due to careful optimization of photoresist processing and electroplating parameters, the Au films are of very high purity and record-breaking residual resistivity ratio values above 40, allowing for fast internal absorber thermalization.
△ Less
Submitted 12 September, 2024;
originally announced September 2024.
-
Comparing NASA Discovery and New Frontiers Class Mission Concepts for the Io Volcano Observer (IVO)
Authors:
Christopher W. Hamilton,
Alfred S. McEwen,
Laszlo Keszthelyi,
Lynn M. Carter,
Ashley G. Davies,
Katherine de Kleer,
Kandis Lea Jessup,
Xianzhe Jia,
James T. Keane,
Kathleen Mandt,
Francis Nimmo,
Chris Paranicas,
Ryan S. Park,
Jason E. Perry,
Anne Pommier,
Jani Radebaugh,
Sarah S. Sutton,
Audrey Vorburger,
Peter Wurz,
Cauê Borlina,
Amanda F. Haapala,
Daniella N. DellaGiustina,
Brett W. Denevi,
Sarah M. Hörst,
Sascha Kempf
, et al. (9 additional authors not shown)
Abstract:
Jupiter's moon Io is a highly compelling target for future exploration that offers critical insight into tidal dissipation processes and the geology of high heat flux worlds, including primitive planetary bodies, such as the early Earth, that are shaped by enhanced rates of volcanism. Io is also important for understanding the development of volcanogenic atmospheres and mass-exchange within the Ju…
▽ More
Jupiter's moon Io is a highly compelling target for future exploration that offers critical insight into tidal dissipation processes and the geology of high heat flux worlds, including primitive planetary bodies, such as the early Earth, that are shaped by enhanced rates of volcanism. Io is also important for understanding the development of volcanogenic atmospheres and mass-exchange within the Jupiter System. However, fundamental questions remain about the state of Io's interior, surface, and atmosphere, as well as its role in the evolution of the Galilean satellites. The Io Volcano Observer (IVO) would address these questions by achieving the following three key goals: (A) Determine how and where tidal heat is generated inside Io; (B) Understand how tidal heat is transported to the surface of Io; and (C) Understand how Io is evolving. IVO was selected for Phase A study through the NASA Discovery program in 2020 and, in anticipation of a New Frontiers 5 opportunity, an enhanced IVO-NF mission concept was advanced that would increase the Baseline mission from 10 flybys to 20, with an improved radiation design; employ a Ka-band communications to double IVO's total data downlink; add a wide angle camera for color and stereo mapping; add a dust mass spectrometer; and lower the altitude of later flybys to enable new science. This study compares and contrasts the mission architecture, instrument suite, and science objectives for Discovery (IVO) and New Frontiers (IVO-NF) missions to Io, and advocates for continued prioritization of Io as an exploration target for New Frontiers.
△ Less
Submitted 14 August, 2024;
originally announced August 2024.
-
Development of MMC-based lithium molybdate cryogenic calorimeters for AMoRE-II
Authors:
A. Agrawal,
V. V. Alenkov,
P. Aryal,
H. Bae,
J. Beyer,
B. Bhandari,
R. S. Boiko,
K. Boonin,
O. Buzanov,
C. R. Byeon,
N. Chanthima,
M. K. Cheoun,
J. S. Choe,
S. Choi,
S. Choudhury,
J. S. Chung,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Y. M. Gavrilyuk,
A. M. Gezhaev
, et al. (84 additional authors not shown)
Abstract:
The AMoRE collaboration searches for neutrinoless double beta decay of $^{100}$Mo using molybdate scintillating crystals via low temperature thermal calorimetric detection. The early phases of the experiment, AMoRE-pilot and AMoRE-I, have demonstrated competitive discovery potential. Presently, the AMoRE-II experiment, featuring a large detector array with about 90 kg of $^{100}$Mo isotope, is und…
▽ More
The AMoRE collaboration searches for neutrinoless double beta decay of $^{100}$Mo using molybdate scintillating crystals via low temperature thermal calorimetric detection. The early phases of the experiment, AMoRE-pilot and AMoRE-I, have demonstrated competitive discovery potential. Presently, the AMoRE-II experiment, featuring a large detector array with about 90 kg of $^{100}$Mo isotope, is under construction.This paper discusses the baseline design and characterization of the lithium molybdate cryogenic calorimeters to be used in the AMoRE-II detector modules. The results from prototype setups that incorporate new housing structures and two different crystal masses (316 g and 517 - 521 g), operated at 10 mK temperature, show energy resolutions (FWHM) of 7.55 - 8.82 keV at the 2.615 MeV $^{208}$Tl $γ$ line, and effective light detection of 0.79 - 0.96 keV/MeV. The simultaneous heat and light detection enables clear separation of alpha particles with a discrimination power of 12.37 - 19.50 at the energy region around $^6$Li(n, $α$)$^3$H with Q-value = 4.785 MeV. Promising detector performances were demonstrated at temperatures as high as 30 mK, which relaxes the temperature constraints for operating the large AMoRE-II array.
△ Less
Submitted 16 July, 2024;
originally announced July 2024.
-
Improved limit on neutrinoless double beta decay of \mohundred~from AMoRE-I
Authors:
A. Agrawal,
V. V. Alenkov,
P. Aryal,
J. Beyer,
B. Bhandari,
R. S. Boiko,
K. Boonin,
O. Buzanov,
C. R. Byeon,
N. Chanthima,
M. K. Cheoun,
J. S. Choe,
Seonho Choi,
S. Choudhury,
J. S. Chung,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Y. M. Gavrilyuk,
A. M. Gezhaev,
O. Gileva
, et al. (83 additional authors not shown)
Abstract:
AMoRE searches for the signature of neutrinoless double beta decay of $^{100}$Mo with a 100 kg sample of enriched $^{100}$Mo. Scintillating molybdate crystals coupled with a metallic magnetic calorimeter operate at milli-Kelvin temperatures to measure the energy of electrons emitted in the decay. As a demonstration of the full-scale AMoRE, we conducted AMoRE-I, a pre-experiment with 18 molybdate c…
▽ More
AMoRE searches for the signature of neutrinoless double beta decay of $^{100}$Mo with a 100 kg sample of enriched $^{100}$Mo. Scintillating molybdate crystals coupled with a metallic magnetic calorimeter operate at milli-Kelvin temperatures to measure the energy of electrons emitted in the decay. As a demonstration of the full-scale AMoRE, we conducted AMoRE-I, a pre-experiment with 18 molybdate crystals, at the Yangyang Underground Laboratory for over two years. The exposure was 8.02 kg$\cdot$year (or 3.89 kg$_{\mathrm{^{100}Mo}}\cdot$year) and the total background rate near the Q-value was 0.025 $\pm$ 0.002 counts/keV/kg/year. We observed no indication of $0νββ$ decay and report a new lower limit of the half-life of $^{100}$Mo $0νββ$ decay as $ T^{0ν}_{1/2}>3.0\times10^{24}~\mathrm{years}$ at 90\% confidence level. The effective Majorana mass limit range is $m_{ββ}<$(210--610) meV using nuclear matrix elements estimated in the framework of different models, including the recent shell model calculations.
△ Less
Submitted 8 July, 2024;
originally announced July 2024.
-
Projected background and sensitivity of AMoRE-II
Authors:
A. Agrawal,
V. V. Alenkov,
P. Aryal,
J. Beyer,
B. Bhandari,
R. S. Boiko,
K. Boonin,
O. Buzanov,
C. R. Byeon,
N. Chanthima,
M. K. Cheoun,
J. S. Choe,
Seonho Choi,
S. Choudhury,
J. S. Chung,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Y. M. Gavrilyuk,
A. M. Gezhaev,
O. Gileva
, et al. (81 additional authors not shown)
Abstract:
AMoRE-II aims to search for neutrinoless double beta decay with an array of 423 Li$_2$$^{100}$MoO$_4$ crystals operating in the cryogenic system as the main phase of the Advanced Molybdenum-based Rare process Experiment (AMoRE). AMoRE has been planned to operate in three phases: AMoRE-pilot, AMoRE-I, and AMoRE-II. AMoRE-II is currently being installed at the Yemi Underground Laboratory, located ap…
▽ More
AMoRE-II aims to search for neutrinoless double beta decay with an array of 423 Li$_2$$^{100}$MoO$_4$ crystals operating in the cryogenic system as the main phase of the Advanced Molybdenum-based Rare process Experiment (AMoRE). AMoRE has been planned to operate in three phases: AMoRE-pilot, AMoRE-I, and AMoRE-II. AMoRE-II is currently being installed at the Yemi Underground Laboratory, located approximately 1000 meters deep in Jeongseon, Korea. The goal of AMoRE-II is to reach up to $T^{0νββ}_{1/2}$ $\sim$ 6 $\times$ 10$^{26}$ years, corresponding to an effective Majorana mass of 15 - 29 meV, covering all the inverted mass hierarchy regions. To achieve this, the background level of the experimental configurations and possible background sources of gamma and beta events should be well understood. We have intensively performed Monte Carlo simulations using the GEANT4 toolkit in all the experimental configurations with potential sources. We report the estimated background level that meets the 10$^{-4}$counts/(keV$\cdot$kg$\cdot$yr) requirement for AMoRE-II in the region of interest (ROI) and show the projected half-life sensitivity based on the simulation study.
△ Less
Submitted 14 October, 2024; v1 submitted 13 June, 2024;
originally announced June 2024.
-
Optimal Demodulation Domain for Microwave SQUID Multiplexers in Presence of Readout System Noise
Authors:
M. E. García Redondo,
N. A. Müller,
J. M. Salum,
L. P. Ferreyro,
J. D. Bonilla-Neira,
J. M. Geria,
J. J. Bonaparte,
T. Muscheid,
R. Gartmann,
A. Almela,
M. R. Hampel,
A. E. Fuster,
L. E. Ardila-Perez,
M. Wegner,
M. Platino,
O. Sander,
S. Kempf,
M. Weber
Abstract:
The Microwave SQUID Multiplexer (μMUX) is the device of choice for the readout of a large number of Low-Temperature Detectors in a wide variety of experiments within the fields of astronomy and particle physics. While it offers large multiplexing factors, the system noise performance is highly dependent on the cold and warm-readout electronic systems used to read it out, as well as the demodulatio…
▽ More
The Microwave SQUID Multiplexer (μMUX) is the device of choice for the readout of a large number of Low-Temperature Detectors in a wide variety of experiments within the fields of astronomy and particle physics. While it offers large multiplexing factors, the system noise performance is highly dependent on the cold and warm-readout electronic systems used to read it out, as well as the demodulation domain and parameters chosen. In order to understand the impact of the readout systems in the overall detection system noise performance, first we extended the available μMUX simulation frameworks including additive and multiplicative noise sources in the probing tones (i.e. phase and amplitude noise), along with the capability of demodulating the scientific data, either in resonator's phase or scattering amplitude. Then, considering the additive noise as a dominant noise source, the optimum readout parameters to achieve minimum system noise were found for both open-loop and flux-ramp demodulation schemes in the aforementioned domains. Later, we evaluated the system noise sensitivity to multiplicative noise sources under the optimum readout parameters. Finally, as a case study, we evaluated the optimal demodulation domain and expected system noise level for a typical Software-Defined Radio (SDR) readout system. This work leads to an improved system performance prediction and noise engineering based on the available readout electronics and selected demodulation domain.
△ Less
Submitted 19 August, 2024; v1 submitted 10 June, 2024;
originally announced June 2024.
-
Full-Scale Readout Electronics for the ECHo-100k Experiment
Authors:
T. Muscheid,
R. Gartmann,
N. Karcher,
F. Schuderer,
M. Neidig,
L. E. Ardila-Perez,
M. Balzer,
S. Kempf,
O. Sander
Abstract:
Recent advances in the development of cryogenic particle detectors such as magnetic microcalorimeters (MMCs) allow the fabrication of sensor arrays with an increasing number of pixels. Since these detectors must be operated at the lowest temperatures, the readout of large detector arrays is still quite challenging. This is especially true for the ECHo experiment, which presently aims to simultaneo…
▽ More
Recent advances in the development of cryogenic particle detectors such as magnetic microcalorimeters (MMCs) allow the fabrication of sensor arrays with an increasing number of pixels. Since these detectors must be operated at the lowest temperatures, the readout of large detector arrays is still quite challenging. This is especially true for the ECHo experiment, which presently aims to simultaneously run 6,000 two-pixel detectors to investigate the electron neutrino mass. For this reason, we developed a readout system based on a microwave SQUID multiplexer ($μ$MUX) that is operated by a custom software-defined radio (SDR) at room-temperature. The SDR readout electronics consist of three distinct hardware units: a data processing board with a Xilinx ZynqUS+ MPSoC; a converter board that features DACs, ADCs, and a coherent clock distribution network; and a radio frequency front-end board to translate the signals between the baseband and the microwave domains. Here, we describe the characteristics of the full-scale SDR system. First, the generated frequency comb for driving the $μ$MUX was evaluated. Subsequently, by operating the SDR in direct loopback, the crosstalk of the individual channels after frequency demultiplexing was investigated. Finally, the system was used with a 16-channel $μ$MUX to evaluate the linearity of the SDR, and the noise contributed to the overall readout setup.
△ Less
Submitted 3 April, 2024;
originally announced April 2024.
-
Anodization-free fabrication process for high-quality cross-type Josephson tunnel junctions based on a Nb/Al-AlO$_x$/Nb trilayer
Authors:
Fabienne Bauer,
Christian Enss,
Sebastian Kempf
Abstract:
Josephson tunnel junctions form the basis for various superconducting electronic devices. For this reason, enormous efforts are routinely taken to establish and later on maintain a scalable and reproducible wafer-scale manufacturing process for high-quality Josephson junctions. Here, we present an anodization-free fabrication process for Nb/Al-AlO$_x$/Nb cross-type Josephson junctions that require…
▽ More
Josephson tunnel junctions form the basis for various superconducting electronic devices. For this reason, enormous efforts are routinely taken to establish and later on maintain a scalable and reproducible wafer-scale manufacturing process for high-quality Josephson junctions. Here, we present an anodization-free fabrication process for Nb/Al-AlO$_x$/Nb cross-type Josephson junctions that requires only a small number of process steps and that is intrinsically compatible with wafer-scale fabrication. We show that the fabricated junctions are of very high-quality and, compared to other junction types, exhibit not only a significantly reduced capacitance but also an almost rectangular critical current density profile. Our process hence enables the usage of low capacitance Josephson junctions for superconducting electronic devices such as ultra-low noise dc-SQUIDs, microwave SQUID multiplexers based on non-hysteretic rf-SQUIDs and RFSQ circuits.
△ Less
Submitted 4 March, 2024;
originally announced March 2024.
-
Background study of the AMoRE-pilot experiment
Authors:
A. Agrawal,
V. V. Alenkov,
P. Aryal,
J. Beyer,
B. Bhandari,
R. S. Boiko,
K. Boonin,
O. Buzanov,
C. R. Byeon,
N. Chanthima,
M. K. Cheoun,
J. S. Choe,
Seonho Choi,
S. Choudhury,
J. S. Chung,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Yu. M. Gavrilyuk,
A. M. Gezhaev,
O. Gileva
, et al. (83 additional authors not shown)
Abstract:
We report a study on the background of the Advanced Molybdenum-Based Rare process Experiment (AMoRE), a search for neutrinoless double beta decay (\znbb) of $^{100}$Mo. The pilot stage of the experiment was conducted using $\sim$1.9 kg of \CAMOO~ crystals at the Yangyang Underground Laboratory, South Korea, from 2015 to 2018. We compared the measured $β/γ$ energy spectra in three experimental conf…
▽ More
We report a study on the background of the Advanced Molybdenum-Based Rare process Experiment (AMoRE), a search for neutrinoless double beta decay (\znbb) of $^{100}$Mo. The pilot stage of the experiment was conducted using $\sim$1.9 kg of \CAMOO~ crystals at the Yangyang Underground Laboratory, South Korea, from 2015 to 2018. We compared the measured $β/γ$ energy spectra in three experimental configurations with the results of Monte Carlo simulations and identified the background sources in each configuration. We replaced several detector components and enhanced the neutron shielding to lower the background level between configurations. A limit on the half-life of $0νββ$ decay of $^{100}$Mo was found at $T_{1/2}^{0ν} \ge 3.0\times 10^{23}$ years at 90\% confidence level, based on the measured background and its modeling. Further reduction of the background rate in the AMoRE-I and AMoRE-II are discussed.
△ Less
Submitted 7 April, 2024; v1 submitted 15 January, 2024;
originally announced January 2024.
-
Magnetic microcalorimeters for primary activity standardization within the EMPIR project PrimA-LTD
Authors:
Michael Müller,
Matias Rodrigues,
Jörn Beyer,
Martin Loidl,
Sebastian Kempf
Abstract:
The precision of existing decay data of radionuclides for activity determination is often a limitation for actual applications in science, society, and industry. For this reason, the EMPIR project PrimA-LTD aims to introduce an advanced primary activity standardization technique that is based on magnetic microcalorimeters (MMCs) and that will offer very low energy threshold of few eV and a decay s…
▽ More
The precision of existing decay data of radionuclides for activity determination is often a limitation for actual applications in science, society, and industry. For this reason, the EMPIR project PrimA-LTD aims to introduce an advanced primary activity standardization technique that is based on magnetic microcalorimeters (MMCs) and that will offer very low energy threshold of few eV and a decay scheme independent detection efficiency close to 100%. As a proof of concept, we developed two MMC-based detector types in order to standardize an $α$-decaying, a $β$-decaying and an electron capture decaying isotope. One detector type aims to introduce a reusable detector setup, while the other aims to provide highly accurate decay spectra by high resolution measurements with high statistics. We present the designs, fabrication status and first characterization measurements of both detectors types and outline next steps.
△ Less
Submitted 15 December, 2023; v1 submitted 26 October, 2023;
originally announced October 2023.
-
Design considerations for the optimization of λ-SQUIDs
Authors:
Constantin Schuster,
Sebastian Kempf
Abstract:
Cryogenic microcalorimeters are key tools for high-resolution X-ray spectroscopy due to their excellent energy resolution and quantum efficiency close to 100%. Multiple types of microcalorimeters exist, some of which have already proven outstanding performance. Nevertheless, they can't yet compete with cutting-edge grating or crystal spectrometers. For this reason, novel microcalorimeter concepts…
▽ More
Cryogenic microcalorimeters are key tools for high-resolution X-ray spectroscopy due to their excellent energy resolution and quantum efficiency close to 100%. Multiple types of microcalorimeters exist, some of which have already proven outstanding performance. Nevertheless, they can't yet compete with cutting-edge grating or crystal spectrometers. For this reason, novel microcalorimeter concepts are continuously developed. One such concept is based on the strong temperature dependence of the magnetic penetration depth of a superconductor operated close to its transition temperature. This so-called $λ$-SQUID provides an in-situ tunable gain and promises to reach sub-eV energy resolution. Here, we present some design considerations with respect to the optimization of such a detector that are derived by analytic means. We particularly show that for this detector concept the heat capacity of the sensor should match the heat capacity of the absorber.
△ Less
Submitted 25 October, 2023;
originally announced October 2023.
-
Magnetic microcalorimeter with paramagnetic temperature sensors and integrated dc-SQUID readout for high-resolution X-ray emission spectroscopy
Authors:
Matthäus Krantz,
Francesco Toschi,
Benedikt Maier,
Greta Heine,
Christian Enss,
Sebastian Kempf
Abstract:
We present two variants of a magnetic microcalorimeter with paramagnetic temperature sensors and integrated dc-SQUID readout for high-resolution X-ray emission spectroscopy. Each variant employs two overhanging gold absorbers with a sensitive area of 150$μ$m x 150$μ$m and a thickness of 3$μ$m, thus providing a quantum efficiency of 98% for photons up to 5keV and 50% for photons up to 10keV. The fi…
▽ More
We present two variants of a magnetic microcalorimeter with paramagnetic temperature sensors and integrated dc-SQUID readout for high-resolution X-ray emission spectroscopy. Each variant employs two overhanging gold absorbers with a sensitive area of 150$μ$m x 150$μ$m and a thickness of 3$μ$m, thus providing a quantum efficiency of 98% for photons up to 5keV and 50% for photons up to 10keV. The first variant turned out to be fully operational, but, at the same time, to suffer from Joule power dissipation of the Josephson junction shunt resistors, athermal phonon loss, and slew rate limitations of the overall setup. Overall, it only achieved an energy resolution $ΔE_\mathrm{FWHM} = 8.9eV$. In the second variant, we introduced an innovative `tetrapod absorber geometry' as well as a membrane-technique for protecting the temperature sensors against the power dissipation of the shunt resistors. By this, the second variant achieves an outstanding energy resolution of $ΔE_\mathrm{FWHM} =1.25(18)eV$ and hence provides, to our knowledge, the present best energy resolving power $E/ΔE_\mathrm{FWHM}$ among all existing energy-dispersive detectors for soft and tender X-rays.
△ Less
Submitted 12 October, 2023;
originally announced October 2023.
-
Optimum filter-based analysis for the characterization of a high-resolution magnetic microcalorimeter towards the DELight experiment
Authors:
Francesco Toschi,
Benedikt Maier,
Greta Heine,
Torben Ferber,
Sebastian Kempf,
Markus Klute,
Belina von Krosigk
Abstract:
Ultra-sensitive cryogenic calorimeters have become a favored technology with widespread application where eV-scale energy resolutions are needed. In this article, we characterize the performance of an X-ray magnetic microcalorimeter (MMC) using a Fe-55 source. Employing an optimum filter-based amplitude estimation and energy reconstruction, we demonstrate that an unprecedented FWHM resolution of…
▽ More
Ultra-sensitive cryogenic calorimeters have become a favored technology with widespread application where eV-scale energy resolutions are needed. In this article, we characterize the performance of an X-ray magnetic microcalorimeter (MMC) using a Fe-55 source. Employing an optimum filter-based amplitude estimation and energy reconstruction, we demonstrate that an unprecedented FWHM resolution of $ΔE_\mathrm{FWHM} = \left(1.25\pm0.17\mathrm{\scriptsize{(stat)}}^{+0.05}_{-0.07}\mathrm{\scriptsize{(syst)}}\right)\,\text{eV}$ can be achieved. We also derive the best possible resolution and discuss limiting factors affecting the measurement. The analysis pipeline for the MMC data developed in this paper is furthermore an important step for the realization of the proposed superfluid helium-based experiment DELight, which will search for direct interaction of dark matter with masses below 100 MeV/c$^2$.
△ Less
Submitted 12 October, 2023;
originally announced October 2023.
-
SQUID-based superconducting microcalorimeter with in-situ tunable gain
Authors:
Constantin Schuster,
Sebastian Kempf
Abstract:
Cryogenic microcalorimeters are outstanding tools for X-ray spectroscopy due to their unique combination of excellent energy resolution and close to 100% detection efficiency. While well-established microcalorimeter concepts have already proven impressive performance, their energy resolution has yet to improve to be competitive with cutting-edge wavelength-dispersive grating or crystal spectromete…
▽ More
Cryogenic microcalorimeters are outstanding tools for X-ray spectroscopy due to their unique combination of excellent energy resolution and close to 100% detection efficiency. While well-established microcalorimeter concepts have already proven impressive performance, their energy resolution has yet to improve to be competitive with cutting-edge wavelength-dispersive grating or crystal spectrometers. We hence present an innovative SQUID-based superconducting microcalorimeter with an in-situ tunable gain as alternative concept that is based on the strong temperature dependence of the magnetic penetration depth of a superconductor operated close to its critical temperature. Measurements using a prototype device show no sign for any hysteresis effects that often spoil the performance of superconducting microcalorimeters. Moreover, our predictions of the achievable energy resolution show that a competitive energy resolution O(300meV) with a suitable combination of absorber and sensor material should be easily possible.
△ Less
Submitted 14 November, 2023; v1 submitted 5 October, 2023;
originally announced October 2023.
-
High precision measurement of the $^{99}$Tc $β$ spectrum
Authors:
Michael Paulsen,
Philipp Ranitzsch,
Martin Loidl,
Matias Rodrigues,
Karsten Kossert,
Xavier Mougeot,
Abilasha Singh,
Sylvain Leblond,
Jörn Beyer,
Lina Bockhorn,
Christian Enss,
Mathias Wegner,
Sebastian Kempf,
Ole Nähle
Abstract:
Highly precise measurements of the $^{99}$Tc beta spectrum were performed in two laboratories using metallic magnetic calorimeters. Independent sample preparations, evaluation methods and analyses yield consistent results and the spectrum could be measured down to less than 1 keV. Consistent beta spectra were also obtained via cross-evaluations of the experimental data sets. An additional independ…
▽ More
Highly precise measurements of the $^{99}$Tc beta spectrum were performed in two laboratories using metallic magnetic calorimeters. Independent sample preparations, evaluation methods and analyses yield consistent results and the spectrum could be measured down to less than 1 keV. Consistent beta spectra were also obtained via cross-evaluations of the experimental data sets. An additional independent measurement with silicon detectors in a $4π$ configuration confirms the spectrum shape above 25 keV. Detailed theoretical calculations were performed including nuclear structure and atomic effects. The spectrum shape was found to be sensitive to the effective value of the axial-vector coupling constant. Combining measurements and predictions, we extracted $Q_β=$295.82(16) keV and $g_A^{\text{eff}} = 1.530 (83)$. Furthermore, we derived the mean energy of the beta spectrum $\overline{E}_β$=98.45(20) keV, $\log f = -0.47660 (22)$ and $\log ft = 12.3478 (23)$.
△ Less
Submitted 4 October, 2023; v1 submitted 25 September, 2023;
originally announced September 2023.
-
Simultaneous MMC readout using a tailored μMUX based readout system
Authors:
Daniel Richter,
Mathias Wegner,
Felix Ahrens,
Christian Enss,
Nick Karcher,
Oliver Sander,
Constantin Schuster,
Marc Weber,
Thomas Wolber,
Sebastian Kempf
Abstract:
Magnetic microcalorimeters (MMCs) are cryogenic, energy-dispersive single-particle detectors providing excellent energy resolution, intrinsically fast signal rise time, quantum efficiency close to 100\%, large dynamic range as well as almost ideal linear response. One of the remaining challenges to be overcome to ultimately allow for the utilization of large-scale MMC based detector arrays with th…
▽ More
Magnetic microcalorimeters (MMCs) are cryogenic, energy-dispersive single-particle detectors providing excellent energy resolution, intrinsically fast signal rise time, quantum efficiency close to 100\%, large dynamic range as well as almost ideal linear response. One of the remaining challenges to be overcome to ultimately allow for the utilization of large-scale MMC based detector arrays with thousands to millions of individual pixels is the realization of a SQUID based multiplexing technique particularly tailored for MMC readout. Within this context, we report on the first truly multiplexed readout of an MMC based detector array using a frequency-division multiplexing approach realized by a custom microwave SQUID multiplexer based readout system.
△ Less
Submitted 27 March, 2023; v1 submitted 14 November, 2022;
originally announced November 2022.
-
Moonraker -- Enceladus Multiple Flyby Mission
Authors:
O. Mousis,
A. Bouquet,
Y. Langevin,
N. André,
H. Boithias,
G. Durry,
F. Faye,
P. Hartogh,
J. Helbert,
L. Iess,
S. Kempf,
A. Masters,
F. Postberg,
J. -B. Renard,
P. Vernazza,
A. Vorburger,
P. Wurz,
D. H. Atkinson,
S. Barabash,
M. Berthomier,
J. Brucato,
M. Cable,
J. Carter,
S. Cazaux,
A. Coustenis
, et al. (28 additional authors not shown)
Abstract:
Enceladus, an icy moon of Saturn, possesses an internal water ocean and jets expelling ocean material into space. Cassini investigations indicated that the subsurface ocean could be a habitable environment having a complex interaction with the rocky core. Further investigation of the composition of the plume formed by the jets is necessary to fully understand the ocean, its potential habitability,…
▽ More
Enceladus, an icy moon of Saturn, possesses an internal water ocean and jets expelling ocean material into space. Cassini investigations indicated that the subsurface ocean could be a habitable environment having a complex interaction with the rocky core. Further investigation of the composition of the plume formed by the jets is necessary to fully understand the ocean, its potential habitability, and what it tells us about Enceladus' origin. Moonraker has been proposed as an ESA M-class mission designed to orbit Saturn and perform multiple flybys of Enceladus, focusing on traversals of the plume. The proposed Moonraker mission consists of an ESA-provided platform, with strong heritage from JUICE and Mars Sample Return, and carrying a suite of instruments dedicated to plume and surface analysis. The nominal Moonraker mission has a duration of 13.5 years. It includes a 23-flyby segment with 189 days allocated for the science phase, and can be expanded with additional segments if resources allow. The mission concept consists in investigating: i) the habitability conditions of present-day Enceladus and its internal ocean, ii) the mechanisms at play for the communication between the internal ocean and the surface of the South Polar Terrain, and iii) the formation conditions of the moon. Moonraker, thanks to state-of-the-art instruments representing a significant improvement over Cassini's payload, would quantify the abundance of key species in the plume, isotopic ratios, and physical parameters of the plume and the surface. Such a mission would pave the way for a possible future landed mission.
△ Less
Submitted 1 November, 2022;
originally announced November 2022.
-
DELight: a Direct search Experiment for Light dark matter with superfluid helium
Authors:
Belina von Krosigk,
Klaus Eitel,
Christian Enss,
Torben Ferber,
Loredana Gastaldo,
Felix Kahlhoefer,
Sebastian Kempf,
Markus Klute,
Sebastian Lindemann,
Marc Schumann,
Francesco Toschi,
Kathrin Valerius
Abstract:
To reach ultra-low detection thresholds necessary to probe unprecedentedly low Dark Matter masses, target material alternatives and novel detector designs are essential. One such target material is superfluid $^4$He which has the potential to probe so far uncharted light Dark Matter parameter space at sub-GeV masses. The new ``Direct search Experiment for Light dark matter'', DELight, will be usin…
▽ More
To reach ultra-low detection thresholds necessary to probe unprecedentedly low Dark Matter masses, target material alternatives and novel detector designs are essential. One such target material is superfluid $^4$He which has the potential to probe so far uncharted light Dark Matter parameter space at sub-GeV masses. The new ``Direct search Experiment for Light dark matter'', DELight, will be using superfluid helium as active target, instrumented with magnetic micro-calorimeters. It is being designed to reach sensitivity to masses well below 100\,MeV in Dark Matter-nucleus scattering interactions.
△ Less
Submitted 22 September, 2022;
originally announced September 2022.
-
Suitability of Magnetic Microbolometers based on Paramagnetic Temperature Sensors for CMB Polarization Measurements
Authors:
Juan Manuel Geria,
Matias Rolf Hampel,
Sebastian Kempf,
Juan Jose Bonaparte,
Luciano Pablo Ferreyro,
Manuel Elías García Redondo,
Daniel Alejandro Almela,
Juan Manuel Salum,
Nahuel Müller,
Jesus David Bonilla-Neira,
Alan Ezequiel Fuster,
Manuel Platino,
Alberto Etchegoyen
Abstract:
High resolution maps of polarization anisotropies of the Cosmic Microwave Background (CMB) are in high demand, since the discovery of primordial B-Modes in the polarization patterns would confirm the inflationary phase of the Universe that would have taken place before the last scattering of the CMB at the recombination epoch. Transition Edge Sensors (TES) and Microwave Kinetic Inductance Detector…
▽ More
High resolution maps of polarization anisotropies of the Cosmic Microwave Background (CMB) are in high demand, since the discovery of primordial B-Modes in the polarization patterns would confirm the inflationary phase of the Universe that would have taken place before the last scattering of the CMB at the recombination epoch. Transition Edge Sensors (TES) and Microwave Kinetic Inductance Detectors (MKID) are the predominant detector technologies of cryogenic detector array based CMB instruments that search for primordial B-Modes. In this paper we propose another type of cryogenic detector to be used for CMB survey: A magnetic microbolometer (MMB) that is based on a paramagnetic temperature sensor. It is an adaption of state-of-the-art metallic magnetic calorimeters (MMCs) that are meanwhile a key technology for high resolution $α$, $β$, $γ$ and X-ray spectroscopy as well as the study of neutrino mass. The effort to adapt MMCs for CMB surveys is triggered by their lack of Johnson noise associated with the detector readout, the possibility of straightforward calibration and higher dynamic range given it possesses a broad and smooth responsivity dependence with temperature and the absence of Joule dissipation which simplifies the thermal design. A brief proof of concept case study is analyzed, taking into account typical constraints in CMB measurements and reliable microfabrication processes. The results show that MMBs provide a promising technology for CMB polarization survey as their sensitivity can be tuned for background limited detection of the sky while simultaneously maintaining a low time response to avoid distortion of the point-source response of the telescope. As the sensor technology and its fabrication techniques are compatible with TES based bolometric detector arrays, a change of detector technology would even come with very low cost.
△ Less
Submitted 10 June, 2024; v1 submitted 13 September, 2022;
originally announced September 2022.
-
Simulation framework for microwave SQUID multiplexer optimization
Authors:
Constantin Schuster,
Mathias Wegner,
Sebastian Kempf
Abstract:
So far, performance prediction and optimization of microwave SQUID multiplexers has largely been based on simple approximate analytical models and experimental results. This is caused by the complexity of the underlying physics and the intricacy of operation and readout parameters. As a simplified description can never account for all potential effects occurring in a real device, we have developed…
▽ More
So far, performance prediction and optimization of microwave SQUID multiplexers has largely been based on simple approximate analytical models and experimental results. This is caused by the complexity of the underlying physics and the intricacy of operation and readout parameters. As a simplified description can never account for all potential effects occurring in a real device, we have developed a software framework to simulate the characteristics and performance of a microwave SQUID multiplexer. Our simulation framework is a powerful tool to guide understanding and optimization of microwave SQUID multiplexers and other related devices. It includes common readout schemes such as open-loop or flux ramp modulated readout as well as the nonlinear behavior of Josephson tunnel junctions. Moreover, it accounts for the non-zero response time of superconducting microwave resonators with high loaded quality factors as well as the most significant noise contributions such as amplifier noise, resonator noise as well as SQUID noise. This ultimately leads to a prediction of device performance that is significantly better as compared simple analytical methods. Using the simulation framework, we discuss first steps towards a full microwave SQUID multiplexer optimization and highlight some other applications which our simulation framework can be used for.
△ Less
Submitted 10 January, 2023; v1 submitted 3 August, 2022;
originally announced August 2022.
-
Flux ramp modulation based hybrid microwave SQUID multiplexer
Authors:
Constantin Schuster,
Mathias Wegner,
Christian Enss,
Sebastian Kempf
Abstract:
We present a hybrid microwave SQUID multiplexer that combines two frequency-division multiplexing techniques to allow multiplexing a given number of cryogenic detectors with only a fraction of frequency encoding resonators. Similar to conventional microwave SQUID multiplexing, our multiplexer relies on inductively coupling non-hysteretic, unshunted rf-SQUIDs to superconducting microwave resonators…
▽ More
We present a hybrid microwave SQUID multiplexer that combines two frequency-division multiplexing techniques to allow multiplexing a given number of cryogenic detectors with only a fraction of frequency encoding resonators. Similar to conventional microwave SQUID multiplexing, our multiplexer relies on inductively coupling non-hysteretic, unshunted rf-SQUIDs to superconducting microwave resonators as well as applying flux ramp modulation for output signal linearization. However, instead of utilizing one resonator per SQUID, we couple multiple SQUIDs to a common readout resonator and encode the SQUID input signals in sidebands of the microwave carrier by varying the flux ramp modulation frequency for each SQUID. We prove the suitability of our approach using a prototype device and argue by means of fundamental information theory that our approach is particularly suited for reading out large cryogenic bolometer arrays.
△ Less
Submitted 11 February, 2022;
originally announced February 2022.
-
Analytical model of the readout power and SQUID hysteresis parameter dependence of the resonator characteristics of microwave SQUID multiplexers
Authors:
Mathias Wegner,
Christian Enss,
Sebastian Kempf
Abstract:
We report on the development of an analytical model describing the readout power and SQUID hysteresis parameter dependence of the resonator characteristics used for frequency encoding in microwave SQUID multiplexers. Within the context of this model, we derived the different dependencies by analyzing the Fourier components of the non-linear response of the non-hysteretic rf-SQUID. We show that our…
▽ More
We report on the development of an analytical model describing the readout power and SQUID hysteresis parameter dependence of the resonator characteristics used for frequency encoding in microwave SQUID multiplexers. Within the context of this model, we derived the different dependencies by analyzing the Fourier components of the non-linear response of the non-hysteretic rf-SQUID. We show that our model contains the existing model as a limiting case, leading to identical analytical expressions for small readout powers. Considering the approximations we made, our model is valid for rf-SQUID hysteresis parameters $β_{\mathrm{L}} < 0.6$ which fully covers the parameter range of existing multiplexer devices. We conclude our work with an experimental verification of the model. In particular, we demonstrate a very good agreement between measured multiplexer characteristics and predictions based on our model.
△ Less
Submitted 15 December, 2021;
originally announced December 2021.
-
Metallic magnetic calorimeter arrays for the first phase of the ECHo experiment
Authors:
F. Mantegazzini,
A. Barth,
H. Dorrer,
Ch. E. Düllmann,
C. Enss,
A. Fleischmann,
R. Hammann,
S. Kempf,
T. Kieck,
N. Kovac,
C. Velte,
M. Wegner,
K. Wendt,
T. Wickenhäuser,
L. Gastaldo
Abstract:
The ECHo experiment has been designed for the determination of the effective electron neutrino mass by means of the analysis of the end-point region of the Ho-163 electron capture spectrum. Metallic magnetic calorimeters enclosing Ho-163 are used for the high energy resolution calorimetric measurement of the Ho-163 spectrum. For the first phase of the experiment, ECHo-1k, a 72-pixel MMC array has…
▽ More
The ECHo experiment has been designed for the determination of the effective electron neutrino mass by means of the analysis of the end-point region of the Ho-163 electron capture spectrum. Metallic magnetic calorimeters enclosing Ho-163 are used for the high energy resolution calorimetric measurement of the Ho-163 spectrum. For the first phase of the experiment, ECHo-1k, a 72-pixel MMC array has been developed. The single-pixel design has been optimised to reach 100% stopping power for the radiation emitted in the Ho-163 electron capture process (besides the electron neutrino) and an energy resolution < 10 eV FWHM. We describe the design of the ECHo-1k detector chip, the fabrication steps and the characterisation at room temperature, at 4 K and at the final operation temperatures. In particular, a detailed analysis of the results from these tests allowed to define a quality check protocol based on parameters measurable at room temperature. We discuss the performance achieved with the two ECHo-1k detector chips - the first one with Ho-163 implanted in gold and the second one with Ho-163 implanted in silver - which have been used for the high statistics measurement of the ECHo-1k experiment. An average activity per pixel of 0.81 Bq and 0.71 Bq and an average energy resolution of 6.07 eV FWHM and 5.55 eV FWHM have been achieved with these two detectors, fulfilling the requirements for the first phase of the ECHo experiment.
△ Less
Submitted 18 November, 2021;
originally announced November 2021.
-
Online Demodulation and Trigger for Flux-ramp Modulated SQUID Signals
Authors:
N. Karcher,
T. Muscheid,
T. Wolber,
D. Richter,
C. Enss,
S. Kempf,
O. Sander
Abstract:
Due to the periodic characteristics of SQUIDs, a suitable linearization technique is required for SQUID-based readout. Flux-ramp modulation is a common linearization technique and is typically applied for the readout of a microwave-SQUID-multiplexer as well as since recently also for dc-SQUIDs. Flux-ramp modulation requires another stage in the signal processing chain to demodulate the SQUID outpu…
▽ More
Due to the periodic characteristics of SQUIDs, a suitable linearization technique is required for SQUID-based readout. Flux-ramp modulation is a common linearization technique and is typically applied for the readout of a microwave-SQUID-multiplexer as well as since recently also for dc-SQUIDs. Flux-ramp modulation requires another stage in the signal processing chain to demodulate the SQUID output signal before further processing. For cryogenic microcalorimenters, these events are given by fast exponentially rising and slowly exponentially decaying pulses which shall be detected by a trigger engine and recorded by a storage logic. Since the data rate can be decreased significantly by demodulation and event detection, it is desirable to do both steps on the deployed fast FPGA logic during measurement before passing the data to a general-purpose processor.
In this contribution, we show the implementation of efficient multi-channel flux-ramp demodulation computed at run-time on a SoC-FPGA. Furthermore, a concept and implementation for an online trigger and buffer mechanism with its theoretical trigger loss rates depending on buffer size is presented. Both FPGA modules can be operated with up to 500 MHz clock frequency and can efficiently process 32 channels. Correct functionality and data reduction capability of the modules are demonstrated in measurements utilizing magnetic microcalorimeter irradiated with an Iron-55 source for event generation and read out by a microwave SQUID multiplexer.
△ Less
Submitted 22 October, 2021;
originally announced October 2021.
-
Multichannel read-out for arrays of metallic magnetic calorimeters
Authors:
F. Mantegazzini,
S. Allgeier,
A. Barth,
C. Enss,
A. Ferring-Siebert,
A. Fleischmann,
L. Gastaldo,
R. Hammann,
D. Hengstler,
S. Kempf,
D. Richter,
D. Schulz,
D. Unger,
C. Velte,
M. Wegner
Abstract:
Metallic magnetic micro-calorimeters (MMCs) operated at millikelvin temperature offer the possibility to achieve eV-scale energy resolution with high stopping power for X-rays and massive particles in an energy range up to several tens of keV. This motivates their use in a wide range of applications in fields as particle physics, atomic and molecular physics. Present detector systems consist of MM…
▽ More
Metallic magnetic micro-calorimeters (MMCs) operated at millikelvin temperature offer the possibility to achieve eV-scale energy resolution with high stopping power for X-rays and massive particles in an energy range up to several tens of keV. This motivates their use in a wide range of applications in fields as particle physics, atomic and molecular physics. Present detector systems consist of MMC arrays read out by 32 two-stage SQUID read-out channels. In contrast to the design of the detector array and consequently the design of the front-end SQUIDs, which need to be optimised for the physics case and the particles to be detected in a given experiment, the read-out chain can be standardised. We present our new standardised 32-channel parallel read-out for the operation of MMC arrays to be operated in a dilution refrigerator. The read-out system consists of a detector module, whose design depends on the particular application, an amplifier module, ribbon cables from room temperature to the millikelvin platform and a data acquisition system. In particular, we describe the realisation of the read-out system prepared for the ECHo-1k experiment for the operation of two 64-pixel arrays. The same read-out concept is also used for the maXs detector systems, developed for the study of the de-excitation of highly charged heavy ions by X-rays, as well as for the MOCCA system, developed for the energy and position sensitive detection of neutral molecular fragments for the study of fragmentation when molecular ions recombine with electrons. The choice of standard modular components for the operation of 32-channel MMC arrays offer the flexibility to upgrade detector modules without the need of any changes in the read-out system and the possibility to individually exchange parts in case of damages or failures.
△ Less
Submitted 13 October, 2021; v1 submitted 22 February, 2021;
originally announced February 2021.
-
Flux ramp modulation based MHz frequency-division dc-SQUID multiplexer
Authors:
Daniel Richter,
Ludwig Hoibl,
Thomas Wolber,
Nick Karcher,
Andreas Fleischmann,
Christian Enss,
Marc Weber,
Oliver Sander,
Sebastian Kempf
Abstract:
We present a MHz frequency-division dc-SQUID multiplexer that is based on flux ramp modulation and a series array of $N$ identical current-sensing dc-SQUIDs with tightly coupled input coil. By running a periodic, sawtooth-shaped current signal through an additional modulation coil being tightly, but non-uniformly coupled to the individual SQUIDs, the voltage drop across the array changes according…
▽ More
We present a MHz frequency-division dc-SQUID multiplexer that is based on flux ramp modulation and a series array of $N$ identical current-sensing dc-SQUIDs with tightly coupled input coil. By running a periodic, sawtooth-shaped current signal through an additional modulation coil being tightly, but non-uniformly coupled to the individual SQUIDs, the voltage drop across the array changes according to the superposition of the flux-to-voltage characteristics of the individual SQUIDs within each cycle of the modulation signal. In this mode of operation, an input signal injected in the input coil of one of the SQUIDs and being quasi-static within a time frame adds a constant flux offset and leads to a phase shift of the associated SQUID characteristics. The latter is inherently proportional to the input signal and can be inferred by channelizing and down-converting the sampled array output voltage. Using a prototype multiplexer as well as a self-developed high-speed readout electronics for real-time phase determination, we demonstrate the simultaneous readout of four signal sources with MHz bandwidth per channel.
△ Less
Submitted 4 March, 2021; v1 submitted 16 January, 2021;
originally announced January 2021.
-
High-resolution for IAXO: MMC-based X-ray Detectors
Authors:
D. Unger,
A. Abeln,
C. Enss,
A. Fleischmann,
D. Hengstler,
S. Kempf,
L. Gastaldo
Abstract:
Axion helioscopes like the planned International Axion Observatory (IAXO) search for evidence of axions and axion-like particles (ALPs) from the Sun. A strong magnetic field is used to convert ALPs into photons via the generic ALP-photon coupling. To observe the resulting photons, X-ray detectors with low background and high efficiency are necessary. In addition, good energy resolution and low ene…
▽ More
Axion helioscopes like the planned International Axion Observatory (IAXO) search for evidence of axions and axion-like particles (ALPs) from the Sun. A strong magnetic field is used to convert ALPs into photons via the generic ALP-photon coupling. To observe the resulting photons, X-ray detectors with low background and high efficiency are necessary. In addition, good energy resolution and low energy threshold would allow for investigating the ALP properties by studying the X-ray spectrum after its discovery. We propose to use low temperature metallic magnetic calorimeters (MMCs). Here we present the first detector system based on MMCs developed for IAXO and discuss the results of the characterization. The detector consists of a two-dimensional 64-pixel array covering an active area of 16 mm$^2$ with a fill factor of 93 %. We achieve an average energy resolution of 6.1 eV FWHM allowing for energy thresholds below 100 eV. This detector is the first step towards a larger 1 cm$^2$ array matching the IAXO X-ray optics. We determine the background rate for an unshielded detector system in the energy range between 1 keV and 10 keV to be $3.2(1) \times 10^{-4}$ keV$^{-1}$ cm$^{-2}$ s$^{-1}$ from events acquired over 30 days. In the future, active and passive shields will significantly reduce the background induced by cosmic muons and natural radioactivity. Our results demonstrate that MMCs are a promising technology for helioscopes to discover and study ALPs.
△ Less
Submitted 8 June, 2021; v1 submitted 29 October, 2020;
originally announced October 2020.
-
Measurement of the $^{229}$Th isomer energy with a magnetic micro-calorimeter
Authors:
Tomas Sikorsky,
Jeschua Geist,
Daniel Hengstler,
Sebastian Kempf,
Loredana Gastaldo,
Christian Enss,
Christoph Mokry,
Jörg Runke,
Christoph E. Düllmann,
Peter Wobrauschek,
Kjeld Beeks,
Veronika Rosecker,
Johannes H. Sterba,
Georgy Kazakov,
Thorsten Schumm,
Andreas Fleischmann
Abstract:
We present a measurement of the low-energy (0--60$\,$keV) $γ$ ray spectrum produced in the $α$-decay of $^{233}$U using a dedicated cryogenic magnetic micro-calorimeter. The energy resolution of $\sim$$10\,$eV, together with exceptional gain linearity, allow us to measure the energy of the low-lying isomeric state in $^{229}$Th using four complementary evaluation schemes. The most accurate scheme…
▽ More
We present a measurement of the low-energy (0--60$\,$keV) $γ$ ray spectrum produced in the $α$-decay of $^{233}$U using a dedicated cryogenic magnetic micro-calorimeter. The energy resolution of $\sim$$10\,$eV, together with exceptional gain linearity, allow us to measure the energy of the low-lying isomeric state in $^{229}$Th using four complementary evaluation schemes. The most accurate scheme determines the $^{229}$Th isomer energy to be $8.10(17)\,$eV, corresponding to 153.1(37)$\,$nm, superseding in precision previous values based on $γ$ spectroscopy, and agreeing with a recent measurement based on internal conversion electrons. We also measure branching ratios of the relevant excited states to be $b_{29}=9.3(6)\%$ and $b_{42}=0.3(3)\%$.
△ Less
Submitted 27 May, 2020;
originally announced May 2020.
-
Development of a novel calorimetry setup based on metallic paramagnetic temperature sensors
Authors:
Andreas Reifenberger,
Andreas Reiser,
Sebastian Kempf,
Andreas Fleischmann,
Christian Enss
Abstract:
We have developed a new micro-fabricated platform for the measurement of the specific heat of low heat capacity mg-sized metallic samples, such as superconductors, down to temperatures of as low as $10\,\mathrm{mK}$. It addresses challenging aspects of setups of this kind such as the thermal contact between sample and platform, the thermometer resolution, and an addenda heat capacity exceeding tha…
▽ More
We have developed a new micro-fabricated platform for the measurement of the specific heat of low heat capacity mg-sized metallic samples, such as superconductors, down to temperatures of as low as $10\,\mathrm{mK}$. It addresses challenging aspects of setups of this kind such as the thermal contact between sample and platform, the thermometer resolution, and an addenda heat capacity exceeding that of the samples of interest (typically $\mbox{nJ/K at }20\,\mbox{mK}$). The setup allows us to use the relaxation method, where the thermal relaxation following a well defined heat pulse is monitored to extract the specific heat. The sample platform ($5 \times 5\, \mathrm{mm^2}$) includes a micro-structured paramagnetic \underline{Ag}:Er temperature sensor, which is read out by a dc-SQUID via a superconducting flux transformer. In this way, a relative temperature precision of $30\,\mathrm{nK/\sqrt{Hz}}$ can be reached, while the addenda heat capacity falls well below $0.5\,\mathrm{nJ/K}$ for $T < 300\,\mathrm{mK}$. A gold-coated mounting area ($4.4 \times 3 \, \mathrm{mm^2}$) is included to improve the thermal contact between sample and platform.
△ Less
Submitted 2 March, 2020;
originally announced March 2020.
-
Specific Heat of Holmium in Gold and Silver at Low Temperatures
Authors:
Matthew Herbst,
Andreas Reifenberger,
Clemens Velte,
Holger Dorrer,
Christoph E. Düllmann,
Christian Enss,
Andreas Fleischmann,
Loredana Gastaldo,
Sebastian Kempf,
Tom Kieck,
Ulli Köster,
Federica Mantegazzini,
Klaus Wendt
Abstract:
The specific heat of dilute alloys of holmium in gold and in silver plays a major role in the optimization of low temperature microcalorimeters with enclosed $^{163}\textrm{Ho}$, such as the ones developed for the neutrino mass experiment ECHo. We investigate alloys with atomic concentrations of $x_\textrm{Ho}=0.01\,\% - 4\,\%$ at temperatures between $10\,\textrm{mK}$ and $800\,\textrm{mK}$. Due…
▽ More
The specific heat of dilute alloys of holmium in gold and in silver plays a major role in the optimization of low temperature microcalorimeters with enclosed $^{163}\textrm{Ho}$, such as the ones developed for the neutrino mass experiment ECHo. We investigate alloys with atomic concentrations of $x_\textrm{Ho}=0.01\,\% - 4\,\%$ at temperatures between $10\,\textrm{mK}$ and $800\,\textrm{mK}$. Due to the large total angular momentum $J=8$ and nuclear spin $I=7/2$ of $\textrm{Ho}^{3+}$ ions, the specific heat of $\underline{\textrm{Au}}\textrm{:Ho}$ and $\underline{\textrm{Ag}}\textrm{:Ho}$ depends on the detailed interplay of various interactions, including contributions from the localized 4f electrons and nuclear contributions via hyperfine splitting. This makes it difficult to accurately determine the specific heat of these materials numerically. Instead, we measure their specific heat by using three experimental set-ups optimized for different concentration and temperature ranges. The results from measurements on six holmium alloys demonstrate that the specific heat of these materials is dominated by a large Schottky anomaly with its maximum at $T\approx 250\,\textrm{mK}$, which we attribute to hyperfine splitting and crystal field interactions. RKKY and dipole-dipole interactions between the holmium atoms cause additional, concentration-dependent effects. With regard to ECHo, we conclude that for typical operating temperatures of $T\leq 20\,\textrm{mK}$, silver holmium alloys with $x_\textrm{Ho}\gtrsim 1\,\%$ are suited best.
△ Less
Submitted 16 October, 2020; v1 submitted 19 December, 2019;
originally announced December 2019.
-
Software-defined Radio Readout System for the ECHo Experiment
Authors:
Oliver Sander,
Nick Karcher,
Oliver Krömer,
Marc Weber,
Sebastian Kempf,
Mathias Wegner,
Christian Enss
Abstract:
Metallic magnetic calorimeters (MMCs) are cryogenic detectors that offer an excellent energy resolution, a signal rise time of <100 ns, a high dynamic range and almost optimal linearity. MMCs are of high interest for many experiments. One of them, the ECHo experiment, requires the utilization of large MMC detector arrays. The readout of such MMC arrays is a challenging task, which can be tackled u…
▽ More
Metallic magnetic calorimeters (MMCs) are cryogenic detectors that offer an excellent energy resolution, a signal rise time of <100 ns, a high dynamic range and almost optimal linearity. MMCs are of high interest for many experiments. One of them, the ECHo experiment, requires the utilization of large MMC detector arrays. The readout of such MMC arrays is a challenging task, which can be tackled using software-defined radios (SDRs). Though SDR is a well-known approach in communications engineering, a dedicated implementation for frequency division multiplexed readout of MMCs is new and one of the technological key elements of the ECHo project. ECHo will be the first experiment to use microwave SQUID multiplexed MMC detectors and therefore pioneering the hardware, firmware and software development in this domain. This paper presents the detailed concepts and current status of the development.
△ Less
Submitted 24 June, 2018;
originally announced June 2018.
-
Solar System Ice Giants: Exoplanets in our Backyard
Authors:
Abigail Rymer,
Kathleen Mandt,
Dana Hurley,
Carey Lisse,
Noam Izenberg,
H. Todd Smith,
Joseph Westlake,
Emma Bunce,
Christopher Arridge,
Adam Masters,
Mark Hofstadter,
Amy Simon,
Pontus Brandt,
George Clark,
Ian Cohen,
Robert Allen,
Sarah Vine,
Kenneth Hansen,
George Hospodarsky,
William Kurth,
Paul Romani,
Laurent Lamy,
Philippe Zarka,
Hao Cao,
Carol Paty
, et al. (88 additional authors not shown)
Abstract:
Future remote sensing of exoplanets will be enhanced by a thorough investigation of our solar system Ice Giants (Neptune-size planets). What can the configuration of the magnetic field tell us (remotely) about the interior, and what implications does that field have for the structure of the magnetosphere; energy input into the atmosphere, and surface geophysics (for example surface weathering of s…
▽ More
Future remote sensing of exoplanets will be enhanced by a thorough investigation of our solar system Ice Giants (Neptune-size planets). What can the configuration of the magnetic field tell us (remotely) about the interior, and what implications does that field have for the structure of the magnetosphere; energy input into the atmosphere, and surface geophysics (for example surface weathering of satellites that might harbour sub-surface oceans). How can monitoring of auroral emission help inform future remote observations of emission from exoplanets? Our Solar System provides the only laboratory in which we can perform in-situ experiments to understand exoplanet formation, dynamos, systems and magnetospheres.
△ Less
Submitted 10 April, 2018;
originally announced April 2018.
-
The Cosmic Dust Analyzer onboard Cassini: ten years of discoveries
Authors:
Ralf Srama,
Sascha Kempf,
Georg Moragas-Klostermeyer,
Nicolas Altobelli,
Siegfried Auer,
Uwe Beckmann,
Sebastian Bugiel,
Marcia Burton,
Tom Economou,
Hugo Fechtig,
Katherina Fiege,
Simon F. Green,
Manuel Grande,
Ove Havnes,
Jon K. Hillier,
Stefan Helfert,
Mihaly Horanyi,
Sean Hsu,
Eduard Igenbergs,
E. K. Jessberger,
Torrence V. Johnson,
Emil Khalisi,
Harald Krüger,
Günter Matt,
Anna Mocker
, et al. (16 additional authors not shown)
Abstract:
The interplanetary space probe Cassini/Huygens reached Saturn in July 2004 after seven years of cruise phase. The Cosmic Dust Analyzer (CDA) measures the interplanetary, interstellar and planetary dust in our solar system since 1999 and provided unique discoveries. In 1999, CDA detected interstellar dust in the inner solar system followed by the detection of electrical charges of interplanetary du…
▽ More
The interplanetary space probe Cassini/Huygens reached Saturn in July 2004 after seven years of cruise phase. The Cosmic Dust Analyzer (CDA) measures the interplanetary, interstellar and planetary dust in our solar system since 1999 and provided unique discoveries. In 1999, CDA detected interstellar dust in the inner solar system followed by the detection of electrical charges of interplanetary dust grains during the cruise phase between Earth and Jupiter. The instrument determined the composition of interplanetary dust and the nanometre sized dust streams originating from Jupiter's moon Io. During the approach to Saturn in 2004, similar streams of submicron grains with speeds in the order of 100 km/s were detected from Saturn's inner and outer ring system and are released to the interplanetary magnetic field. Since 2004 CDA measured more than one million dust impacts characterizing the dust environment of Saturn. The instrument is one of three experiments which discovered the active ice geysers located at the south pole of Saturn's moon Enceladus in 2005. Later, a detailed compositional analysis of the water ice grains in Saturn's E ring system lead to the discovery of large reservoirs of liquid water (oceans) below the icy crust of Enceladus. Finally, the determination of the dust- magnetosphere interaction and the discovery of the extended E ring (at least twice as large as predicted) allowed the definition of a dynamical dust model of Saturn's E ring describing the observed properties. This paper summarizes the discoveries of a ten year story of success based on reliable measurements with the most advanced dust detector flown in space until today. This paper focuses on cruise results and findings achieved at Saturn with a focus on flux and density measurements.
△ Less
Submitted 13 February, 2018;
originally announced February 2018.
-
Surface Deposition of the Enceladus Plume and the Zenith Angle of Emissions
Authors:
Ben Southworth,
Sascha Kempf,
Joe Spitale
Abstract:
Since the discovery of an ice particle plume erupting from the south polar terrain on Saturn's moon Enceladus, the geophysical mechanisms driving its activity have been the focus of substantial scientific research. The pattern and deposition rate of plume material on Enceladus' surface is of interest because it provides valuable information about the dynamics of the ice particle ejection as well a…
▽ More
Since the discovery of an ice particle plume erupting from the south polar terrain on Saturn's moon Enceladus, the geophysical mechanisms driving its activity have been the focus of substantial scientific research. The pattern and deposition rate of plume material on Enceladus' surface is of interest because it provides valuable information about the dynamics of the ice particle ejection as well as the surface erosion. Surface deposition maps derived from numerical plume simulations by Kempf et al. (2010) have been used by various researchers to interpret data obtained by various Cassini instruments. Here, an updated and detailed set of deposition maps is provided based on a deep-source plume model (Schmidt et al., 2008), for the eight ice-particle jets identified in Spitale and Porco (2007), the updated set of jets proposed in Porco et al. (2014), and a contrasting curtain-style plume proposed in Spitale et al. (2015). Methods for computing the surface deposition are detailed, and the structure of surface deposition patterns is shown to be consistent across changes in the production rate and size distribution of the plume. Maps are also provided of the surface deposition structure originating in each of the four Tiger Stripes. Finally, the differing approaches used in Porco et al. (2014) and Spitale et al. (2015) have given rise to a jets vs. curtains controversy regarding the emission structure of the Enceladus plume. Here we simulate each, leading to new insight that, over time, most emissions must be directed relatively orthogonal to the surface because jets "tilted" significantly away from orthogonal lead to surface deposition patterns inconsistent with surface images.
Data for maps are available in HDF5 format for a variety of particle sizes at http://impact.colorado.edu/southworth_data.
△ Less
Submitted 22 August, 2018; v1 submitted 30 January, 2018;
originally announced January 2018.
-
A White Paper on keV Sterile Neutrino Dark Matter
Authors:
R. Adhikari,
M. Agostini,
N. Anh Ky,
T. Araki,
M. Archidiacono,
M. Bahr,
J. Baur,
J. Behrens,
F. Bezrukov,
P. S. Bhupal Dev,
D. Borah,
A. Boyarsky,
A. de Gouvea,
C. A. de S. Pires,
H. J. de Vega,
A. G. Dias,
P. Di Bari,
Z. Djurcic,
K. Dolde,
H. Dorrer,
M. Durero,
O. Dragoun,
M. Drewes,
G. Drexlin,
Ch. E. Düllmann
, et al. (111 additional authors not shown)
Abstract:
We present a comprehensive review of keV-scale sterile neutrino Dark Matter, collecting views and insights from all disciplines involved - cosmology, astrophysics, nuclear, and particle physics - in each case viewed from both theoretical and experimental/observational perspectives. After reviewing the role of active neutrinos in particle physics, astrophysics, and cosmology, we focus on sterile ne…
▽ More
We present a comprehensive review of keV-scale sterile neutrino Dark Matter, collecting views and insights from all disciplines involved - cosmology, astrophysics, nuclear, and particle physics - in each case viewed from both theoretical and experimental/observational perspectives. After reviewing the role of active neutrinos in particle physics, astrophysics, and cosmology, we focus on sterile neutrinos in the context of the Dark Matter puzzle. Here, we first review the physics motivation for sterile neutrino Dark Matter, based on challenges and tensions in purely cold Dark Matter scenarios. We then round out the discussion by critically summarizing all known constraints on sterile neutrino Dark Matter arising from astrophysical observations, laboratory experiments, and theoretical considerations. In this context, we provide a balanced discourse on the possibly positive signal from X-ray observations. Another focus of the paper concerns the construction of particle physics models, aiming to explain how sterile neutrinos of keV-scale masses could arise in concrete settings beyond the Standard Model of elementary particle physics. The paper ends with an extensive review of current and future astrophysical and laboratory searches, highlighting new ideas and their experimental challenges, as well as future perspectives for the discovery of sterile neutrinos.
△ Less
Submitted 9 February, 2017; v1 submitted 15 February, 2016;
originally announced February 2016.
-
Cryogenic micro-calorimeters for mass spectrometric identification of neutral molecules and molecular fragments
Authors:
O. Novotný,
S. Allgeier,
C. Enss,
A. Fleischmann,
L. Gamer,
D. Hengstler,
S. Kempf,
C. Krantz,
A. Pabinger,
C. Pies,
D. W. Savin,
D. Schwalm,
A. Wolf
Abstract:
We have systematically investigated the energy resolution of a magnetic micro-calorimeter (MMC) for atomic and molecular projectiles at impact energies ranging from $E\approx13$ to 150 keV. For atoms we obtained absolute energy resolutions down to $ΔE \approx 120$ eV and relative energy resolutions down to $ΔE/E\approx10^{-3}$. We also studied in detail the MMC energy-response function to molecula…
▽ More
We have systematically investigated the energy resolution of a magnetic micro-calorimeter (MMC) for atomic and molecular projectiles at impact energies ranging from $E\approx13$ to 150 keV. For atoms we obtained absolute energy resolutions down to $ΔE \approx 120$ eV and relative energy resolutions down to $ΔE/E\approx10^{-3}$. We also studied in detail the MMC energy-response function to molecular projectiles of up to mass 56 u. We have demonstrated the capability of identifying neutral fragmentation products of these molecules by calorimetric mass spectrometry. We have modeled the MMC energy-response function for molecular projectiles and conclude that backscattering is the dominant source of the energy spread at the impact energies investigated. We have successfully demonstrated the use of a detector absorber coating to suppress such spreads. We briefly outline the use of MMC detectors in experiments on gas-phase collision reactions with neutral products. Our findings are of general interest for mass spectrometric techniques, particularly for those desiring to make neutral-particle mass measurements.
△ Less
Submitted 12 June, 2015; v1 submitted 27 May, 2015;
originally announced May 2015.
-
First Calorimetric Measurement of OI-line in the Electron Capture Spectrum of $^{163}$Ho
Authors:
P. C. -O. Ranitzsch,
C. Hassel,
M. Wegner,
S. Kempf,
A. Fleischmann,
C. Enss,
L. Gastaldo,
A. Herlert,
K. Johnston
Abstract:
The isotope $^{163}$Ho undergoes an electron capture process with a recommended value for the energy available to the decay, $Q_{\rm EC}$, of about 2.5 keV. According to the present knowledge, this is the lowest $Q_{\rm EC}$ value for electron capture processes. Because of that, $^{163}$Ho is the best candidate to perform experiments to investigate the value of the electron neutrino mass based on…
▽ More
The isotope $^{163}$Ho undergoes an electron capture process with a recommended value for the energy available to the decay, $Q_{\rm EC}$, of about 2.5 keV. According to the present knowledge, this is the lowest $Q_{\rm EC}$ value for electron capture processes. Because of that, $^{163}$Ho is the best candidate to perform experiments to investigate the value of the electron neutrino mass based on the analysis of the calorimetrically measured spectrum.
We present for the first time the calorimetric measurement of the atomic de-excitation of the $^{163}$Dy daughter atom upon the capture of an electron from the 5s shell in $^{163}$Ho, OI-line. The measured peak energy is 48 eV. This measurement was performed using low temperature metallic magnetic calorimeters with the $^{163}$Ho ion implanted in the absorber.
We demonstrate that the calorimetric spectrum of $^{163}$Ho can be measured with high precision and that the parameters describing the spectrum can be learned from the analysis of the data. Finally, we discuss the implications of this result for the Electron Capture $^{163}$Ho experiment, ECHo, aiming to reach sub-eV sensitivity on the electron neutrino mass by a high precision and high statistics calorimetric measurement of the $^{163}$Ho spectrum.
△ Less
Submitted 29 August, 2014;
originally announced September 2014.
-
The Electron Capture $^{163}$Ho Experiment ECHo: an overview
Authors:
L. Gastaldo,
K. Blaum,
A. Doerr,
Ch. E. Duellmann,
K. Eberhardt,
S. Eliseev,
C. Enss,
Amand Faessler,
A. Fleischmann,
S. Kempf,
M. Krivoruchenko,
S. Lahiri,
M. Maiti,
Yu. N. Novikov,
P. C. -O. Ranitzsch,
F. Simkovic,
Z. Szusc,
M. Wegner
Abstract:
The determination of the absolute scale of the neutrino masses is one of the most challenging present questions in particle physics. The most stringent limit, $m(\barν_{\mathrm{e}})<2$eV, was achieved for the electron anti-neutrino mass \cite{numass}. Different approaches are followed to achieve a sensitivity on neutrino masses in the sub-eV range. Among them, experiments exploring the beta decay…
▽ More
The determination of the absolute scale of the neutrino masses is one of the most challenging present questions in particle physics. The most stringent limit, $m(\barν_{\mathrm{e}})<2$eV, was achieved for the electron anti-neutrino mass \cite{numass}. Different approaches are followed to achieve a sensitivity on neutrino masses in the sub-eV range. Among them, experiments exploring the beta decay or electron capture of suitable nuclides can provide information on the electron neutrino mass value. We present the Electron Capture $^{163}$Ho experiment ECHo, which aims to investigate the electron neutrino mass in the sub-eV range by means of the analysis of the calorimetrically measured energy spectrum following electron capture of $^{163}$Ho. A high precision and high statistics spectrum will be measured with arrays of metallic magnetic calorimeters. We discuss some of the essential aspects of ECHo to reach the proposed sensitivity: detector optimization and performance, multiplexed readout, $^{163}$Ho source production and purification, as well as a precise theoretical and experimental parameterization of the calorimetric EC spectrum including in particular the value of $Q_{\mathrm{EC}}$. We present preliminary results obtained with a first prototype of single channel detectors as well as a first 64-pixel chip with integrated micro-wave SQUID multiplexer, which will already allow to investigate $m(ν_{\mathrm{e}})$ in the eV range.
△ Less
Submitted 20 September, 2013;
originally announced September 2013.
-
Multiplexed readout of MMC detector arrays using non-hysteretic rf-SQUIDs
Authors:
S. Kempf,
M. Wegner,
L. Gastaldo,
A. Fleischmann,
C. Enss
Abstract:
Metallic magnetic calorimeters (MMCs) are widely used for various experiments in fields ranging from atomic and nuclear physics to x-ray spectroscopy, laboratory astrophysics or material science. Whereas in previous experiments single pixel detectors or small arrays have been used, for future applications large arrays are needed. Therefore, suitable multiplexing techniques for MMC arrays are curre…
▽ More
Metallic magnetic calorimeters (MMCs) are widely used for various experiments in fields ranging from atomic and nuclear physics to x-ray spectroscopy, laboratory astrophysics or material science. Whereas in previous experiments single pixel detectors or small arrays have been used, for future applications large arrays are needed. Therefore, suitable multiplexing techniques for MMC arrays are currently under development. A promising approach for the readout of large arrays is the microwave SQUID multiplexer that operates in the frequency domain and that employs non-hysteretic rf-SQUIDs to transduce the detector signals into a frequency shift of high $Q$ resonators which can be monitored by using standard microwave measurement techniques. In this paper we discuss the design and the expected performance of a recently developed and fabricated 64 pixel detector array with integrated microwave SQUID multiplexer. First experimental data were obtained characterizing dc-SQUIDs with virtually identical washer design.
△ Less
Submitted 19 September, 2013;
originally announced September 2013.
-
The Electron Capture $^{163}$Ho Experiment ECHo
Authors:
K. Blaum,
A. Doerr,
C. E. Duellmann,
K. Eberhardt,
S. Eliseev,
C. Enss,
A. Faessler,
A. Fleischmann,
L. Gastaldo,
S. Kempf,
M. Krivoruchenko,
S. Lahiri,
M. Maiti,
Yu. N. Novikov,
P. C. -O. Ranitzsch,
F. Simkovic,
Z. Szusc,
M. Wegner
Abstract:
The determination of the absolute scale of the neutrino masses is one of the most challenging questions in particle physics. Different approaches are followed to achieve a sensitivity on neutrino masses in the sub-eV range. Among them, experiments exploring the beta decay and electron capture processes of suitable nuclides can provide necessary information on the electron neutrino mass value. In t…
▽ More
The determination of the absolute scale of the neutrino masses is one of the most challenging questions in particle physics. Different approaches are followed to achieve a sensitivity on neutrino masses in the sub-eV range. Among them, experiments exploring the beta decay and electron capture processes of suitable nuclides can provide necessary information on the electron neutrino mass value. In this talk we present the Electron Capture 163-Ho experiment ECHo, which aims to investigate the electron neutrino mass in the sub-eV range by means of the analysis of the calorimetrically measured energy spectrum following the electron capture process of 163-Ho. A high precision and high statistics spectrum will be measured by means of low temperature magnetic calorimeter arrays. We present preliminary results obtained with a first prototype of single channel detectors as well as the participating groups and their on-going developments.
△ Less
Submitted 11 June, 2013;
originally announced June 2013.
-
Characterization of low temperature metallic magnetic calorimeters having gold absorbers with implanted $^{163}$Ho ions
Authors:
L. Gastaldo,
P. Ranitzsch,
F. von Seggern,
J. -P. Porst,
S. Schäfer,
C. Pies,
S. Kempf,
T. Wolf,
A. Fleischmann,
C. Enss,
A. Herlert,
K. Johnston
Abstract:
For the first time we have investigated the behavior of fully micro-fabricated low temperature metallic magnetic calorimeters (MMCs) after undergoing an ion-implantation process. This experiment had the aim to show the possibility to perform a high precision calorimetric measurement of the energy spectrum following the electron capture of $^{163}$Ho using MMCs having the radioactive $^{163}$Ho ion…
▽ More
For the first time we have investigated the behavior of fully micro-fabricated low temperature metallic magnetic calorimeters (MMCs) after undergoing an ion-implantation process. This experiment had the aim to show the possibility to perform a high precision calorimetric measurement of the energy spectrum following the electron capture of $^{163}$Ho using MMCs having the radioactive $^{163}$Ho ions implanted in the absorber. The implantation of $^{163}$Ho ions was performed at ISOLDE-CERN. The performance of a detector that underwent an ion-implantation process is compared to the one of a detector without implanted ions. The results show that the implantation dose of ions used in this experiment does not compromise the properties of the detector. In addition an optimized detector design for future $^{163}$Ho experiments is presented.
△ Less
Submitted 25 June, 2012;
originally announced June 2012.
-
The Sky in Dust -- Methods and Prospects of Dust Astronomy
Authors:
M. Landgraf,
E. Grün,
R. Srama,
S. Helfert,
S. Kempf,
G. Morgas-Klostermeyer,
M. Rachev,
A. Srowig,
S. Auer,
M. Horànyi,
Z. Sternovsky,
D. Harris
Abstract:
Information about the make-up of the galaxy arrives in the Solar system in many forms: photons of different energies, classically collected by ground- and space-based telescopes, neutral and charged atomic particles, and solid macroscopic particles: cosmic dust particles. Dust particles, like photons, carry information from remote sites in space and time. This information can be analysed in orde…
▽ More
Information about the make-up of the galaxy arrives in the Solar system in many forms: photons of different energies, classically collected by ground- and space-based telescopes, neutral and charged atomic particles, and solid macroscopic particles: cosmic dust particles. Dust particles, like photons, carry information from remote sites in space and time. This information can be analysed in order to understand the processes and mechanisms that are involved in the formation and evolution of solid matter in the galaxy. This approach is called ``Dust Astronomy'' which is carried out by means of a dust telescope on a dust observatory in space. The analysis of cosmic grains collected in the high atmosphere of the Earth has shown that each dust grain is a small world with various sub-grains featuring different galactic origin and evolution, which is identified on the basis of elementary and isotopic analysis. Independent information about the origin and evolution of the grains coming from the kinematic properties of the arrival trajectory would be invaluable for linking the isotopic signature of the formation of heavy elements in old stars and supernovae to distinctive regions in our galaxy, e.g. known star-forming regions. Here we present a skymap of potential dust sources together with a report on already existing lab hardware of a trajectory sensor and a large-area mass spectrometre.
△ Less
Submitted 4 February, 2006;
originally announced February 2006.
-
Jovian Dust Streams: A monitor of Io's volcanic plume activity
Authors:
Harald Krueger,
Paul Geissler,
Mihaly Horanyi,
Amara L. Graps,
Sascha Kempf,
Ralf Srama,
Georg Moragas-Klostermeyer,
Richard Moissl,
Torrence V. Johnson,
Eberhard Gruen
Abstract:
Streams of high speed dust particles originate from Jupiter's innermost Galilean moon Io. After release from Io, the particles collect electric charges in the Io plasma torus, gain energy from the co-rotating electric field of Jupiter's magnetosphere, and leave the Jovian system into interplanetary space with escape speeds over $\rm 200 km s^{-1}$. Galileo, which was the first orbiter spacecraft…
▽ More
Streams of high speed dust particles originate from Jupiter's innermost Galilean moon Io. After release from Io, the particles collect electric charges in the Io plasma torus, gain energy from the co-rotating electric field of Jupiter's magnetosphere, and leave the Jovian system into interplanetary space with escape speeds over $\rm 200 km s^{-1}$. Galileo, which was the first orbiter spacecraft of Jupiter, has continuously monitored the dust streams during 34 revolutions about the planet between 1996 and 2002. The observed dust fluxes exhibit large orbit-to-orbit variability due to systematic and stochastic changes. After removal of the systematic variations, the total dust emission rate of Io has been calculated. It varies between $10^{-3}$ and $\mathrm{10} \rm kg s^{-1}$, and is typically in the range of 0.1 to $\rm 1 kg s^{-1}$. We compare the dust emission rate with other markers of volcanic activity on Io like large-area surface changes caused by volcanic deposits and sightings of volcanic plumes.
△ Less
Submitted 1 September, 2003;
originally announced September 2003.
-
N-body calculations of cluster growth in proto-planetary disks
Authors:
S. Kempf,
S. Pfalzner,
Th. Henning
Abstract:
We investigated numerically the dust growth driven by Brownian motion in a proto-planetary disc around a solar-type young stellar object. This process is considered as the first stage in the transformation of the initially micron-sized solid particles to a planetary system. In contrast to earlier studies the growth was investigated at the small particle number densities typical for the condition…
▽ More
We investigated numerically the dust growth driven by Brownian motion in a proto-planetary disc around a solar-type young stellar object. This process is considered as the first stage in the transformation of the initially micron-sized solid particles to a planetary system. In contrast to earlier studies the growth was investigated at the small particle number densities typical for the conditions in a proto-planetary disc. Under such circumstances, the mean particle distance exceeds the typical aggregate diameter by orders of magnitude, and a collision will be a very rare event. We derived a criterion which allows an efficient detection of candidates for imminent collisions. The N-particle-method we used is based upon an adaptive time step scheme respecting the individual dynamical states of the aggregates. Its basic concept is to perform on average constant ``length steps'', instead of using constant time steps. The numerical cost of the algorithm scales with the particle number better than N log N. In order to minimise the influence of the decreasing number of particles within the simulation box, a new rescaling method is used throughout the aggregation process. Our numerical results indicate that at very low number densities, the growth process is influenced by spatial number density fluctuations.
△ Less
Submitted 12 February, 1999;
originally announced February 1999.