-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
Sub - THz Radiation from Dielectric Capillaries with Reflectors
Authors:
K. Lekomtsev,
A. Aryshev,
A. A. Tishchenko,
M. Shevelev,
A. A. Ponomarenko,
P. Karataev,
N. Terunuma,
J. Urakawa
Abstract:
In this report we present experimental investigations of THz radiation generated from a corrugated and a non-corrugated capillary with reflectors, using a femtosecond electron beam of LUCX accelerator at KEK, Japan. We discuss measurements of radiation angular distributions and their comparison with Particle In Cell simulations, and also investigate an off-central propagation of the beam in the ca…
▽ More
In this report we present experimental investigations of THz radiation generated from a corrugated and a non-corrugated capillary with reflectors, using a femtosecond electron beam of LUCX accelerator at KEK, Japan. We discuss measurements of radiation angular distributions and their comparison with Particle In Cell simulations, and also investigate an off-central propagation of the beam in the capillaries based on experimental measurements and simulations.
△ Less
Submitted 24 May, 2017;
originally announced June 2017.
-
Monochromaticity of coherent Smith-Purcell radiation from finite size grating
Authors:
A. Aryshev,
A. Potylitsyn,
G. Naumenko,
M. Shevelev,
K. Lekomtsev,
L. Sukhikh,
P. Karataev,
Y. Honda,
N. Terunuma,
J. Urakawa
Abstract:
Investigation of coherent Smith-Purcell Radiation (SPR) spectral characteristics was performed both experimentally and by numerical simulation. The measurement of SPR spectral line shapes of different diffraction orders was carried out at KEK LUCX facility. A pair of room-temperature Schottky barrier diode (SBD) detectors with sensitivity bands of $60-90$~GHz and $320-460$~GHz was used in the meas…
▽ More
Investigation of coherent Smith-Purcell Radiation (SPR) spectral characteristics was performed both experimentally and by numerical simulation. The measurement of SPR spectral line shapes of different diffraction orders was carried out at KEK LUCX facility. A pair of room-temperature Schottky barrier diode (SBD) detectors with sensitivity bands of $60-90$~GHz and $320-460$~GHz was used in the measurements. Reasonable agreement of experimental results and simulations performed with CST Studio Suite justifies the use of different narrow-band SBD detectors to investigate different SPR diffraction orders. It was shown that monochromaticity of the SPR spectral lines increases with diffraction order. The comparison of coherent transition radiation and coherent SPR intensities in sub-THz frequency range showed that the brightnesses of both radiation mechanisms were comparable. A fine tuning feasibility of the SPR spectral lines is discussed.
△ Less
Submitted 11 January, 2017;
originally announced January 2017.
-
Updated baseline for a staged Compact Linear Collider
Authors:
The CLIC,
CLICdp collaborations,
:,
M. J. Boland,
U. Felzmann,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
C. Balazs,
T. K. Charles,
K. Afanaciev,
I. Emeliantchik,
A. Ignatenko,
V. Makarenko,
N. Shumeiko,
A. Patapenka,
I. Zhuk,
A. C. Abusleme Hoffman,
M. A. Diaz Gutierrez,
M. Vogel Gonzalez,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu
, et al. (493 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-q…
▽ More
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of centre-of-mass energy and it targets optimal physics output based on the current physics landscape. The optimised staging scenario foresees three main centre-of-mass energy stages at 380 GeV, 1.5 TeV and 3 TeV for a full CLIC programme spanning 22 years. For the first stage, an alternative to the CLIC drive beam scheme is presented in which the main linac power is produced using X-band klystrons.
△ Less
Submitted 27 March, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
Laserwire at the Accelerator Test Facility 2 with Sub-Micrometre Resolution
Authors:
L. J. Nevay,
S. T. Boogert,
P. Karataev,
K. Kruchinin,
L. Corner,
D. F. Howell,
R. Walczak,
A. Aryshev,
J. Urakawa,
N. Terunuma
Abstract:
A laserwire transverse electron beam size measurement system has been developed and operated at the Accelerator Test Facility 2 (ATF2) at KEK. Special electron beam optics were developed to create an approximately 1 x 100 μm (vertical x horizontal) electron beam at the laserwire location, which was profiled using a 150 mJ, 71 ps laser pulse with a wavelength of 532 nm. The precise characterisation…
▽ More
A laserwire transverse electron beam size measurement system has been developed and operated at the Accelerator Test Facility 2 (ATF2) at KEK. Special electron beam optics were developed to create an approximately 1 x 100 μm (vertical x horizontal) electron beam at the laserwire location, which was profiled using a 150 mJ, 71 ps laser pulse with a wavelength of 532 nm. The precise characterisation of the laser propagation allows the non-Gaussian transverse profiles of the electron beam caused by the laser divergence to be deconvolved. A minimum vertical electron beam size of 1.07 ${\pm}$ 0.06 (stat.) ${\pm}$ 0.05 (sys.) μm was measured. A vertically focussing quadrupole just before the laserwire was varied whilst making laserwire measurements and the projected vertical emittance was measured to be 82.56 ${\pm}$ 3.04 pm rad.
△ Less
Submitted 29 May, 2014; v1 submitted 1 April, 2014;
originally announced April 2014.
-
Observation of the Stimulated Coherent Diffraction Radiation in an Open Resonator at LUCX Facility
Authors:
A. Aryshev,
S. Araki,
M. Fukuda,
N. Terunuma,
J. Urakawa,
P. Karataev,
G. Naumenko,
A. Potylitsyn,
L. Sukhikh,
D. Verigin,
K. Sakaue
Abstract:
We present an initial test of a new type of a pre-bunched beam pumped free electron maser based on Stimulated Coherent Diffraction Radiation (SCDR) generated in an open resonator. An ultra-fast Schottky Barrier Diode (time response $<1\,$ns) has enabled to investigate the properties of the radiation stored in the cavity as well as the intrinsic properties of the cavity itself. We observed a turn-b…
▽ More
We present an initial test of a new type of a pre-bunched beam pumped free electron maser based on Stimulated Coherent Diffraction Radiation (SCDR) generated in an open resonator. An ultra-fast Schottky Barrier Diode (time response $<1\,$ns) has enabled to investigate the properties of the radiation stored in the cavity as well as the intrinsic properties of the cavity itself. We observed a turn-by-turn SCDR generated by a multibunch beam. When the cavity length was exactly a half of the bunch spacing a clear resonance was observed. Moreover, turn-by-turn measurements revealed the cavity quality factor of $72.88$, which was rather high for an open resonator in the wavelength range of $3-5\,$mm. An exponential growth of the photon intensity as a function of the number of bunches was also demonstrated.
△ Less
Submitted 29 October, 2013;
originally announced October 2013.
-
Present status and first results of the final focus beam line at the KEK Accelerator Test Facility
Authors:
P. Bambade,
M. Alabau Pons,
J. Amann,
D. Angal-Kalinin,
R. Apsimon,
S. Araki,
A. Aryshev,
S. Bai,
P. Bellomo,
D. Bett,
G. Blair,
B. Bolzon,
S. Boogert,
G. Boorman,
P. N. Burrows,
G. Christian,
P. Coe,
B. Constance,
Jean-Pierre Delahaye,
L. Deacon,
E. Elsen,
A. Faus-Golfe,
M. Fukuda,
J. Gao,
N. Geffroy
, et al. (69 additional authors not shown)
Abstract:
ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, Europe…
▽ More
ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U.S. scientists. The present status and first results are described.
△ Less
Submitted 5 July, 2012;
originally announced July 2012.
-
Status of the ATF extraction line laser-wire
Authors:
Nicolas Delerue,
Fred Gannaway,
David Howell,
Grahame Blair,
Gary Boorman,
Chafik Driouichi,
Stewart Boogert,
Alexander Aryshev,
Pavel Karataev,
Nobuhiro Terunuma,
Junji Urakawa,
Axel Brachmann,
Joe Frisch,
Marc Ross
Abstract:
A new laser-wire is being installed in the extraction line of the ATF at KEK. This device aims at demonstrating that laser-wires can be used to measure micrometre scale beam size.
A new laser-wire is being installed in the extraction line of the ATF at KEK. This device aims at demonstrating that laser-wires can be used to measure micrometre scale beam size.
△ Less
Submitted 18 January, 2006;
originally announced January 2006.
-
Resonant Diffraction Radiation from an Ultrarelativistic Particle Moving Close to a Tilted Grating
Authors:
A. P. Potylitsyn,
P. V. Karataev,
G. A. Naumenko
Abstract:
A simple model for calculating the diffraction radiation characteristics from an ultrarelativistic charged particle moving close to a tilted ideally conducting strip is developed. Resonant diffraction radiation (RDR) is treated as a superposition of the radiation fields for periodically spaced strips. The RDR characteristics have been calculated as a function of the number of grating elements, t…
▽ More
A simple model for calculating the diffraction radiation characteristics from an ultrarelativistic charged particle moving close to a tilted ideally conducting strip is developed. Resonant diffraction radiation (RDR) is treated as a superposition of the radiation fields for periodically spaced strips. The RDR characteristics have been calculated as a function of the number of grating elements, tilted angle, and initial particle energy. An analogy with both the resonant transition radiation in absorbing medium and the parametric X-ray radiation is noted.
△ Less
Submitted 15 February, 2000; v1 submitted 27 June, 1999;
originally announced June 1999.