-
The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs
Authors:
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
S. Aviles,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame,
J. Bensinger
, et al. (365 additional authors not shown)
Abstract:
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherent…
▽ More
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherently low radioactivity content. The LZ collaboration performed an extensive radioassay campaign over a period of six years to inform material selection for construction and provide an input to the experimental background model against which any possible signal excess may be evaluated. The campaign and its results are described in this paper. We present assays of dust and radon daughters depositing on the surface of components as well as cleanliness controls necessary to maintain background expectations through detector construction and assembly. Finally, examples from the campaign to highlight fixed contaminant radioassays for the LZ photomultiplier tubes, quality control and quality assurance procedures through fabrication, radon emanation measurements of major sub-systems, and bespoke detector systems to assay scintillator are presented.
△ Less
Submitted 28 February, 2022; v1 submitted 3 June, 2020;
originally announced June 2020.
-
The Laser-hybrid Accelerator for Radiobiological Applications
Authors:
G. Aymar,
T. Becker,
S. Boogert,
M. Borghesi,
R. Bingham,
C. Brenner,
P. N. Burrows,
T. Dascalu,
O. C. Ettlinger,
S. Gibson,
T. Greenshaw,
S. Gruber,
D. Gujral,
C. Hardiman,
J. Hughes,
W. G. Jones,
K. Kirkby,
A. Kurup,
J-B. Lagrange,
K. Long,
W. Luk,
J. Matheson,
P. McKenna,
R. Mclauchlan,
Z. Najmudin
, et al. (15 additional authors not shown)
Abstract:
The `Laser-hybrid Accelerator for Radiobiological Applications', LhARA, is conceived as a novel, uniquely-flexible facility dedicated to the study of radiobiology. The technologies demonstrated in LhARA, which have wide application, will be developed to allow particle-beam therapy to be delivered in a completely new regime, combining a variety of ion species in a single treatment fraction and expl…
▽ More
The `Laser-hybrid Accelerator for Radiobiological Applications', LhARA, is conceived as a novel, uniquely-flexible facility dedicated to the study of radiobiology. The technologies demonstrated in LhARA, which have wide application, will be developed to allow particle-beam therapy to be delivered in a completely new regime, combining a variety of ion species in a single treatment fraction and exploiting ultra-high dose rates. LhARA will be a hybrid accelerator system in which laser interactions drive the creation of a large flux of protons or light ions that are captured using a plasma (Gabor) lens and formed into a beam. The laser-driven source allows protons and ions to be captured at energies significantly above those that pertain in conventional facilities, thus evading the current space-charge limit on the instantaneous dose rate that can be delivered. The laser-hybrid approach, therefore, will allow the vast ``terra incognita'' of the radiobiology that determines the response of tissue to ionising radiation to be studied with protons and light ions using a wide variety of time structures, spectral distributions, and spatial configurations at instantaneous dose rates up to and significantly beyond the ultra-high dose-rate `FLASH' regime.
It is proposed that LhARA be developed in two stages. In the first stage, a programme of in vitro radiobiology will be served with proton beams with energies between 10MeV and 15MeV. In stage two, the beam will be accelerated using a fixed-field accelerator (FFA). This will allow experiments to be carried out in vitro and in vivo with proton beam energies of up to 127MeV. In addition, ion beams with energies up to 33.4MeV per nucleon will be available for in vitro and in vivo experiments. This paper presents the conceptual design for LhARA and the R&D programme by which the LhARA consortium seeks to establish the facility.
△ Less
Submitted 31 May, 2020;
originally announced June 2020.
-
The LUX-ZEPLIN (LZ) Experiment
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
J. Barthel,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame
, et al. (357 additional authors not shown)
Abstract:
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient n…
▽ More
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient neutron capture and tagging. LZ is located in the Davis Cavern at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. We describe the major subsystems of the experiment and its key design features and requirements.
△ Less
Submitted 3 November, 2019; v1 submitted 20 October, 2019;
originally announced October 2019.
-
LUX-ZEPLIN (LZ) Technical Design Report
Authors:
B. J. Mount,
S. Hans,
R. Rosero,
M. Yeh,
C. Chan,
R. J. Gaitskell,
D. Q. Huang,
J. Makkinje,
D. C. Malling,
M. Pangilinan,
C. A. Rhyne,
W. C. Taylor,
J. R. Verbus,
Y. D. Kim,
H. S. Lee,
J. Lee,
D. S. Leonard,
J. Li,
J. Belle,
A. Cottle,
W. H. Lippincott,
D. J. Markley,
T. J. Martin,
M. Sarychev,
T. E. Tope
, et al. (237 additional authors not shown)
Abstract:
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
△ Less
Submitted 27 March, 2017;
originally announced March 2017.
-
WIMP-nucleon cross-section results from the second science run of ZEPLIN-III
Authors:
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. Bewick,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
W. G. Jones,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. StJ. Murphy,
F. Neves,
S. M. Paling
, et al. (12 additional authors not shown)
Abstract:
We report experimental upper limits on WIMP-nucleon elastic scattering cross sections from the second science run of ZEPLIN-III at the Boulby Underground Laboratory. A raw fiducial exposure of 1,344 kg.days was accrued over 319 days of continuous operation between June 2010 and May 2011. A total of eight events was observed in the signal acceptance region in the nuclear recoil energy range 7-29 ke…
▽ More
We report experimental upper limits on WIMP-nucleon elastic scattering cross sections from the second science run of ZEPLIN-III at the Boulby Underground Laboratory. A raw fiducial exposure of 1,344 kg.days was accrued over 319 days of continuous operation between June 2010 and May 2011. A total of eight events was observed in the signal acceptance region in the nuclear recoil energy range 7-29 keV, which is compatible with background expectations. This allows the exclusion of the scalar cross-section above 4.8E-8 pb near 50 GeV/c^2 WIMP mass with 90% confidence. Combined with data from the first run, this result improves to 3.9E-8 pb. The corresponding WIMP-neutron spin-dependent cross-section limit is 8.0E-3 pb. The ZEPLIN programme reaches thus its conclusion at Boulby, having deployed and exploited successfully three liquid xenon experiments of increasing reach.
△ Less
Submitted 16 December, 2011; v1 submitted 21 October, 2011;
originally announced October 2011.
-
Limits on inelastic dark matter from ZEPLIN-III
Authors:
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. Bewick,
A. A. Burenkov,
R. Cashmore,
V. Chepel,
A. Currie,
D. Davidge,
J. Dawson,
T. Durkin,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
A. S. Howard,
A. J. Hughes,
W. G. Jones,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
I. Liubarsky
, et al. (21 additional authors not shown)
Abstract:
We present limits on the WIMP-nucleon cross section for inelastic dark matter derived from the 2008 run of ZEPLIN-III. Cuts, notably on scintillation pulse shape and scintillation-to-ionisation ratio, give a net exposure of 63 kg.days in the range 20-80keV nuclear recoil energy, in which 6 events are observed. Upper limits on signal rate are derived from the maximum empty patch in the data. Under…
▽ More
We present limits on the WIMP-nucleon cross section for inelastic dark matter derived from the 2008 run of ZEPLIN-III. Cuts, notably on scintillation pulse shape and scintillation-to-ionisation ratio, give a net exposure of 63 kg.days in the range 20-80keV nuclear recoil energy, in which 6 events are observed. Upper limits on signal rate are derived from the maximum empty patch in the data. Under standard halo assumptions a small region of parameter space consistent, at 99% CL, with causing the 1.17 ton.year DAMA modulation signal is allowed at 90% CL: it is in the mass range 45-60 GeV with a minimum CL of 88%, again derived from the maximum patch. This is the tightest constraint on that explanation of the DAMA result yet presented using a xenon target.
△ Less
Submitted 1 April, 2010; v1 submitted 29 March, 2010;
originally announced March 2010.
-
Limits on the spin-dependent WIMP-nucleon cross-sections from the first science run of the ZEPLIN-III experiment
Authors:
V. N. Lebedenko,
H. M. Araujo,
E. J. Barnes,
A. Bewick,
R. Cashmore,
V. Chepel,
D. Davidge,
J. Dawson,
T. Durkin,
B. Edwards,
C. Ghag,
V. Graffagnino,
M. Horn,
A. S. Howard,
A. J. Hughes,
W. G. Jones,
M. Joshi,
G. E. Kalmus,
A. G. Kovalenko,
A. Lindote,
I. Liubarsky,
M. I. Lopes,
R. Luscher,
K. Lyons,
P. Majewski
, et al. (14 additional authors not shown)
Abstract:
We present new experimental constraints on the WIMP-nucleon spin-dependent elastic cross-sections using data from the first science run of ZEPLIN-III, a two-phase xenon experiment searching for galactic dark matter WIMPs based at the Boulby mine. Analysis of $\sim$450 kg$\cdot$days fiducial exposure revealed a most likely signal of zero events, leading to a 90%-confidence upper limit on the pure…
▽ More
We present new experimental constraints on the WIMP-nucleon spin-dependent elastic cross-sections using data from the first science run of ZEPLIN-III, a two-phase xenon experiment searching for galactic dark matter WIMPs based at the Boulby mine. Analysis of $\sim$450 kg$\cdot$days fiducial exposure revealed a most likely signal of zero events, leading to a 90%-confidence upper limit on the pure WIMP-neutron cross-section of $σ_n=1.8\times 10^{-2}$ pb at 55 GeV/$c^2$ WIMP mass. Recent calculations of the nuclear spin structure based on the Bonn CD nucleon-nucleon potential were used for the odd-neutron isotopes $^{129}$Xe and $^{131}$Xe. These indicate that the sensitivity of xenon targets to the spin-dependent WIMP-proton interaction is much lower than implied by previous calculations, whereas the WIMP-neutron sensitivity is impaired only by a factor of $\sim$2.
△ Less
Submitted 27 January, 2009;
originally announced January 2009.
-
Results from the First Science Run of the ZEPLIN-III Dark Matter Search Experiment
Authors:
V. N. Lebedenko,
H. M. Araujo,
E. J. Barnes,
A. Bewick,
R. Cashmore,
V. Chepel,
A. Currie,
D. Davidge,
J. Dawson,
T. Durkin,
B. Edwards,
C. Ghag,
M. Horn,
A. S. Howard,
A. J. Hughes,
W. G. Jones,
M. Joshi,
G. E. Kalmus,
A. G. Kovalenko,
A. Lindote,
I. Liubarsky,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. StJ. Murphy
, et al. (13 additional authors not shown)
Abstract:
The ZEPLIN-III experiment in the Palmer Underground Laboratory at Boulby uses a 12kg two-phase xenon time projection chamber to search for the weakly interacting massive particles (WIMPs) that may account for the dark matter of our Galaxy. The detector measures both scintillation and ionisation produced by radiation interacting in the liquid to differentiate between the nuclear recoils expected…
▽ More
The ZEPLIN-III experiment in the Palmer Underground Laboratory at Boulby uses a 12kg two-phase xenon time projection chamber to search for the weakly interacting massive particles (WIMPs) that may account for the dark matter of our Galaxy. The detector measures both scintillation and ionisation produced by radiation interacting in the liquid to differentiate between the nuclear recoils expected from WIMPs and the electron recoil background signals down to ~10keV nuclear recoil energy. An analysis of 847kg.days of data acquired between February 27th 2008 and May 20th 2008 has excluded a WIMP-nucleon elastic scattering spin-independent cross-section above 8.1x10(-8)pb at 55GeV/c2 with a 90% confidence limit. It has also demonstrated that the two-phase xenon technique is capable of better discrimination between electron and nuclear recoils at low-energy than previously achieved by other xenon-based experiments.
△ Less
Submitted 2 September, 2009; v1 submitted 5 December, 2008;
originally announced December 2008.
-
First limits on WIMP nuclear recoil signals in ZEPLIN-II: a two phase xenon detector for dark matter detection
Authors:
G. J. Alner,
H. M. Araujo,
A. Bewick,
C. Bungau,
B. Camanzi,
M. J. Carson,
R. J. Cashmore,
H. Chagani,
V. Chepel,
D. Cline,
D. Davidge,
J. C. Davies,
E. Daw,
J. Dawson,
T. Durkin,
B. Edwards,
T. Gamble,
J. Gao,
C. Ghag,
A. S. Howard,
W. G. Jones,
M. Joshi,
E. V. Korolkova,
V. A. Kudryavtsev,
T. Lawson
, et al. (36 additional authors not shown)
Abstract:
Results are presented from the first underground data run of ZEPLIN-II, a 31 kg two phase xenon detector developed to observe nuclear recoils from hypothetical weakly interacting massive dark matter particles. Discrimination between nuclear recoils and background electron recoils is afforded by recording both the scintillation and ionisation signals generated within the liquid xenon, with the ra…
▽ More
Results are presented from the first underground data run of ZEPLIN-II, a 31 kg two phase xenon detector developed to observe nuclear recoils from hypothetical weakly interacting massive dark matter particles. Discrimination between nuclear recoils and background electron recoils is afforded by recording both the scintillation and ionisation signals generated within the liquid xenon, with the ratio of these signals being different for the two classes of event. This ratio is calibrated for different incident species using an AmBe neutron source and Co-60 gamma-ray sources. From our first 31 live days of running ZEPLIN-II, the total exposure following the application of fiducial and stability cuts was 225 kgxdays. A background population of radon progeny events was observed in this run, arising from radon emission in the gas purification getters, due to radon daughter ion decays on the surfaces of the walls of the chamber. An acceptance window, defined by the neutron calibration data, of 50% nuclear recoil acceptance between 5 keVee and 20 keVee, had an observed count of 29 events, with a summed expectation of 28.6+/-4.3 gamma-ray and radon progeny induced background events. These figures provide a 90% c.l. upper limit to the number of nuclear recoils of 10.4 events in this acceptance window, which converts to a WIMP-nucleon spin-independent cross-section with a minimum of 6.6x10^-7 pb following the inclusion of an energy dependent, calibrated, efficiency. A second run is currently underway in which the radon progeny will be eliminated, thereby removing the background population, with a projected sensitivity of 2x10^-7 pb for similar exposures as the first run.
△ Less
Submitted 31 January, 2007; v1 submitted 30 January, 2007;
originally announced January 2007.
-
The ZEPLIN-III dark matter detector: instrument design, manufacture and commissioning
Authors:
D. Yu. Akimov,
G. J. Alner,
H. M. Araujo,
A. Bewick,
C. Bungau,
A. A. Burenkov,
M. J. Carson,
V. Chepel,
D. Cline,
D. Davidge,
J. C. Davies,
E. Daw,
J. Dawson,
T. Durkin,
B. Edwards,
T. Gamble,
C. Chag,
R. J. Hollingworth,
A. S. Howard,
W. G. Jones,
M. Joshi,
J. Kirkpatrick,
A. Kovalenko,
V. A. Kudryavtsev,
I. S. Kuznetsov
, et al. (35 additional authors not shown)
Abstract:
We present details of the technical design and manufacture of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures both the scintillation light and the ionisation charge generated in the liquid by interacting particles and radiation. The instrument design is driven by both the physics requirements and by the technology requirements surrounding the use of…
▽ More
We present details of the technical design and manufacture of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures both the scintillation light and the ionisation charge generated in the liquid by interacting particles and radiation. The instrument design is driven by both the physics requirements and by the technology requirements surrounding the use of liquid xenon. These include considerations of key performance parameters, such as the efficiency of scintillation light collection, restrictions placed on the use of materials to control the inherent radioactivity levels, attainment of high vacuum levels and chemical contamination control. The successful solution has involved a number of novel design and manufacturing features which will be of specific use to future generations of direct dark matter search experiments as they struggle with similar and progressively more demanding requirements.
△ Less
Submitted 19 May, 2006;
originally announced May 2006.
-
The ZEPLIN-III dark matter detector: performance study using an end-to-end simulation tool
Authors:
H. M. Araujo,
D. Yu. Akimov,
G. J. Alner,
A. Bewick,
C. Bungau,
B. Camanzi,
M. J. Carson,
V. Chepel,
H. Chagani,
D. Davidge,
J. C. Davies,
E. Daw,
J. Dawson,
T. Durkin,
B. Edwards,
T. Gamble,
C. Ghag,
R. Hollingworth,
A. S. Howard,
W. G. Jones,
M. Joshi,
J. Kirkpatrick,
A. Kovalenko,
V. A. Kudryavtsev,
V. N. Lebedenko
, et al. (31 additional authors not shown)
Abstract:
We present results from a GEANT4-based Monte Carlo tool for end-to-end simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase detector which measures both the scintillation light and the ionisation charge generated in liquid xenon by interacting particles and radiation. The software models the instrument response to radioactive backgrounds and calibration sources, includ…
▽ More
We present results from a GEANT4-based Monte Carlo tool for end-to-end simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase detector which measures both the scintillation light and the ionisation charge generated in liquid xenon by interacting particles and radiation. The software models the instrument response to radioactive backgrounds and calibration sources, including the generation, ray-tracing and detection of the primary and secondary scintillations in liquid and gaseous xenon, and subsequent processing by data acquisition electronics. A flexible user interface allows easy modification of detector parameters at run time. Realistic datasets can be produced to help with data analysis, an example of which is the position reconstruction algorithm developed from simulated data. We present a range of simulation results confirming the original design sensitivity of a few times $10^{-8}$ pb to the WIMP-nucleon cross-section.
△ Less
Submitted 9 March, 2006;
originally announced March 2006.
-
A Study of the Scintillation Induced by Alpha Particles and Gamma Rays in Liquid Xenon in an Electric Field
Authors:
J. V. Dawson,
A. S. Howard,
D. Akimov,
H. Araujo,
A. Bewick,
D. C. R. Davidge,
W. G. Jones,
M. Joshi,
V. N. Lebedenko,
I. Liubarsky,
J. J. Quenby,
G. Rochester,
D. Shaul,
T. J. Sumner,
R. J. Walker
Abstract:
Scintillation produced in liquid xenon by alpha particles and gamma rays has been studied as a function of applied electric field. For back scattered gamma rays with energy of about 200 keV, the number of scintillation photons was found to decrease by 64+/-2% with increasing field strength. Consequently, the pulse shape discrimination power between alpha particles and gamma rays is found to redu…
▽ More
Scintillation produced in liquid xenon by alpha particles and gamma rays has been studied as a function of applied electric field. For back scattered gamma rays with energy of about 200 keV, the number of scintillation photons was found to decrease by 64+/-2% with increasing field strength. Consequently, the pulse shape discrimination power between alpha particles and gamma rays is found to reduce with increasing field, but remaining non-zero at higher fields.
△ Less
Submitted 7 February, 2005;
originally announced February 2005.
-
The NAIAD experiment for WIMP searches at Boulby mine and recent results
Authors:
B. Ahmed,
G. J. Alner,
H. Araujo,
J. C. Barton,
A. Bewick,
M. J. Carson,
D. Davidge,
J. V. Dawson,
T. Gamble,
S. P. Hart,
R. Hollingworth,
A. S. Howard,
W. G. Jones,
M. K. Joshi,
V. A. Kudryavtsev,
T. B. Lawson,
V. Lebedenko,
M. J. Lehner,
J. D. Lewin,
P. K. Lightfoot,
I. Liubarsky,
R. Luscher,
J. E. McMillan,
B. Morgan,
G. Nicklin
, et al. (10 additional authors not shown)
Abstract:
The NAIAD experiment (NaI Advanced Detector) for WIMP dark matter searches at Boulby mine (UK) is described. The detector consists of an array of encapsulated and unencapsulated NaI(Tl) crystals with high light yield. Six crystals are collecting data at present. Data accumulated by four of them (10.6 kg x year exposure) have been used to set upper limits on the WIMP-nucleon spin-independent and…
▽ More
The NAIAD experiment (NaI Advanced Detector) for WIMP dark matter searches at Boulby mine (UK) is described. The detector consists of an array of encapsulated and unencapsulated NaI(Tl) crystals with high light yield. Six crystals are collecting data at present. Data accumulated by four of them (10.6 kg x year exposure) have been used to set upper limits on the WIMP-nucleon spin-independent and WIMP-proton spin-dependent cross-sections. Pulse shape analysis has been applied to discriminate between nuclear recoils, as may be caused by WIMP interactions, and electron recoils due to gamma background. Various calibrations of crystals are presented.
△ Less
Submitted 31 January, 2003;
originally announced January 2003.
-
Study and suppression of anomalous fast events in inorganic scintillators for dark matter searches
Authors:
V. A. Kudryavtsev,
N. J. C. Spooner,
P. K. Lightfoot,
J. W. Roberts,
M. J. Lehner,
T. Gamble,
M. J. Carson,
T. B. Lawson,
R. Luscher,
J. E. McMillan,
B. Morgan,
S. M. Paling,
M. Robinson,
D. R. Tovey,
N. J. T. Smith,
P. F. Smith,
G. J. Alner,
S. P. Hart,
J. D. Lewin,
R. M. Preece,
T. J. Sumner,
W. G. Jones,
J. J. Quenby,
B. Ahmed,
A. Bewick
, et al. (12 additional authors not shown)
Abstract:
The status of dark matter searches with inorganic scintillator detectors at Boulby mine is reviewed and the results of tests with a CsI(Tl) crystal are presented. The objectives of the latter experiment were to study anomalous fast events previously observed and to identify ways to remove this background. Clear indications were found that these events were due to surface contamination of crystal…
▽ More
The status of dark matter searches with inorganic scintillator detectors at Boulby mine is reviewed and the results of tests with a CsI(Tl) crystal are presented. The objectives of the latter experiment were to study anomalous fast events previously observed and to identify ways to remove this background. Clear indications were found that these events were due to surface contamination of crystals by alphas, probably from radon decay. A new array of unencapsulated NaI(Tl) crystals immersed either in liquid paraffin or pure nitrogen atmosphere is under construction at Boulby. Such an approach allows complete control of the surface of the crystals and the ability to remove any surface contamination. First data from the unencapsulated NaI(Tl) do not show the presence of anomalous fast events.
△ Less
Submitted 12 September, 2001;
originally announced September 2001.
-
Measurements of Scintillation Efficiency and Pulse-Shape for Low Energy Recoils in Liquid Xenon
Authors:
D. Akimov,
A. Bewick,
D. Davidge,
J. Dawson,
A. S. Howard,
I. Ivaniouchenkov,
W. G. Jones,
M. Joshi,
V. A. Kudryavtsev,
T. B. Lawson,
V. Lebedenko,
M. J. Lehner,
P. K. Lightfoot,
I. Liubarsky,
R. Luscher,
J. E. McMillan,
C. D. Peak,
J. J. Quenby,
N. J. C. Spooner,
T. J. Sumner,
D. R. Tovey,
C. K. Ward
Abstract:
Results of observations of low energy nuclear and electron recoil events in liquid xenon scintillator detectors are given. The relative scintillation efficiency for nuclear recoils is 0.22 +/- 0.01 in the recoil energy range 40 keV - 70 keV. Under the assumption of a single dominant decay component to the scintillation pulse-shape the log-normal mean parameter T0 of the maximum likelihood estima…
▽ More
Results of observations of low energy nuclear and electron recoil events in liquid xenon scintillator detectors are given. The relative scintillation efficiency for nuclear recoils is 0.22 +/- 0.01 in the recoil energy range 40 keV - 70 keV. Under the assumption of a single dominant decay component to the scintillation pulse-shape the log-normal mean parameter T0 of the maximum likelihood estimator of the decay time constant for 6 keV < Eee < 30 keV nuclear recoil events is equal to 21.0 ns +/- 0.5 ns. It is observed that for electron recoils T0 rises slowly with energy, having a value ~ 30 ns at Eee ~ 15 keV. Electron and nuclear recoil pulse-shapes are found to be well fitted by single exponential functions although some evidence is found for a double exponential form for the nuclear recoil pulse-shape.
△ Less
Submitted 8 June, 2001;
originally announced June 2001.