Detection of MeV electrons using a charge integrating hybrid pixel detector
Authors:
E. Fröjdh,
F. Baruffaldi,
A. Bergamaschi,
M. Carulla,
R. Dinapoli,
D. Greiffenberg,
J. Heymes,
V. Hinger,
R. Ischebeck,
S. Mathisen,
J. McKenzie,
D. Mezza,
K. Moustakas,
A. Mozzanica,
B. Schmitt,
J. Zhang
Abstract:
Electrons are emerging as a strong complement to X-rays for diffraction based studies. In this paper we investigate the performance of a JUNGFRAU detector with 320 um thick silicon sensor at a pulsed electron source. Originally developed for X-ray detection at free electron lasers, JUNGFRAU features a dynamic range of 120 MeV/pixel (implemented with in-pixel gain switching) which translated to abo…
▽ More
Electrons are emerging as a strong complement to X-rays for diffraction based studies. In this paper we investigate the performance of a JUNGFRAU detector with 320 um thick silicon sensor at a pulsed electron source. Originally developed for X-ray detection at free electron lasers, JUNGFRAU features a dynamic range of 120 MeV/pixel (implemented with in-pixel gain switching) which translated to about 1200 incident electrons per pixel and frame in the MeV region. We preset basic characteristics such as energy deposited per incident particle, resulting cluster size and spatial resolution along with dynamic (intensity) range scans. Measurements were performed at 4, 10 and 20 MeV/c. We compare the measurements with GEANT4 based simulations and extrapolate the results to different sensor thicknesses using these simulations.
△ Less
Submitted 28 October, 2022;
originally announced October 2022.
-
European Strategy for Particle Physics -- Accelerator R&D Roadmap
Authors:
C. Adolphsen,
D. Angal-Kalinin,
T. Arndt,
M. Arnold,
R. Assmann,
B. Auchmann,
K. Aulenbacher,
A. Ballarino,
B. Baudouy,
P. Baudrenghien,
M. Benedikt,
S. Bentvelsen,
A. Blondel,
A. Bogacz,
F. Bossi,
L. Bottura,
S. Bousson,
O. Brüning,
R. Brinkmann,
M. Bruker,
O. Brunner,
P. N. Burrows,
G. Burt,
S. Calatroni,
K. Cassou
, et al. (111 additional authors not shown)
Abstract:
The 2020 update of the European Strategy for Particle Physics emphasised the importance of an intensified and well-coordinated programme of accelerator R&D, supporting the design and delivery of future particle accelerators in a timely, affordable and sustainable way. This report sets out a roadmap for European accelerator R&D for the next five to ten years, covering five topical areas identified…
▽ More
The 2020 update of the European Strategy for Particle Physics emphasised the importance of an intensified and well-coordinated programme of accelerator R&D, supporting the design and delivery of future particle accelerators in a timely, affordable and sustainable way. This report sets out a roadmap for European accelerator R&D for the next five to ten years, covering five topical areas identified in the Strategy update. The R&D objectives include: improvement of the performance and cost-performance of magnet and radio-frequency acceleration systems; investigations of the potential of laser / plasma acceleration and energy-recovery linac techniques; and development of new concepts for muon beams and muon colliders. The goal of the roadmap is to document the collective view of the field on the next steps for the R&D programme, and to provide the evidence base to support subsequent decisions on prioritisation, resourcing and implementation.
△ Less
Submitted 30 March, 2022; v1 submitted 19 January, 2022;
originally announced January 2022.
-
Electron beam transverse phase space tomography using nanofabricated wire scanners with submicrometer resolution
Authors:
Benedikt Hermann,
Vitaliy A. Guzenko,
Orell R. Hürzeler,
Adrian Kirchner,
Gian Luca Orlandi,
Eduard Prat,
Rasmus Ischebeck
Abstract:
Characterization and control of the transverse phase space of high-brightness electron beams is required at free-electron lasers or electron diffraction experiments for emittance measurement and beam optimization as well as at advanced acceleration experiments. Dielectric laser accelerators or plasma accelerators with external injection indeed require beam sizes at the micron level and below. We p…
▽ More
Characterization and control of the transverse phase space of high-brightness electron beams is required at free-electron lasers or electron diffraction experiments for emittance measurement and beam optimization as well as at advanced acceleration experiments. Dielectric laser accelerators or plasma accelerators with external injection indeed require beam sizes at the micron level and below. We present a method using nano-fabricated metallic wires oriented at different angles to obtain projections of the transverse phase space by scanning the wires through the beam and detecting the amount of scattered particles. Performing this measurement at several locations along the waist allows assessing the transverse distribution at different phase advances. By applying a novel tomographic algorithm the transverse phase space density can be reconstructed. Measurements at the ACHIP chamber at SwissFEL confirm that the transverse phase space of micrometer-sized electron beams can be reliably characterized using this method.
△ Less
Submitted 16 February, 2021;
originally announced February 2021.
-
Nano-Fabricated Free-Standing Wire-Scanners with Sub-Micrometer Resolution
Authors:
G. L. Orlandi,
C. David,
E. Ferrari,
V. A. Guzenko,
B. Hermann,
R. Ischebeck,
E. Prat,
M. Ferianis,
G. Penco,
M. Veronese,
N. Cefarin,
S. Dal Zilio,
M. Lazzarino
Abstract:
Diagnostics of the beam transverse profile with ever more demanding spatial resolution is required by the progress on novel particle accelerators - such as laser and plasma driven accelerators - and by the stringent beam specifications of the new generation of X-ray facilities. In a linac driven Free-Electron-Laser (FEL), the spatial resolution constraint joins with the further requirement for the…
▽ More
Diagnostics of the beam transverse profile with ever more demanding spatial resolution is required by the progress on novel particle accelerators - such as laser and plasma driven accelerators - and by the stringent beam specifications of the new generation of X-ray facilities. In a linac driven Free-Electron-Laser (FEL), the spatial resolution constraint joins with the further requirement for the diagnostics to be minimally invasive in order to protect radiation sensitive components - such as the undulators - and to preserve the lasing mechanism. As for high resolution measurements of the beam transverse profile in a FEL, wire-scanners (WS) are the top-ranked diagnostics. Nevertheless, conventional WS consisting of a metallic wire (beam-probe) stretched onto a frame (fork) can provide at best a rms spatial resolution at the micrometer scale along with an equivalent surface of impact on the electron beam. In order to improve the spatial resolution of a WS beyond the micrometer scale along with the transparency to the lasing, PSI and FERMI are independently pursuing the technique of the nano-lithography to fabricate a free-standing and sub-micrometer wide WS beam-probe fully integrated into a fork. Free-standing WS with a geometrical resolution of about 250 nm have been successfully tested at SwissFEL where low charge electron beams with a vertical size of 400-500 nm have been characterized. Further experimental tests carried out at SwissFEL at the nominal beam charge of 200 pC confirmed the resilience to the heat-loading of the nano-fabricated WS. In this work, details on the nano-fabrication of free-standing WS as well as results of the electron-beam characterization are presented.
△ Less
Submitted 30 January, 2020; v1 submitted 20 August, 2019;
originally announced August 2019.
-
Adaptive and Safe Bayesian Optimization in High Dimensions via One-Dimensional Subspaces
Authors:
Johannes Kirschner,
Mojmír Mutný,
Nicole Hiller,
Rasmus Ischebeck,
Andreas Krause
Abstract:
Bayesian optimization is known to be difficult to scale to high dimensions, because the acquisition step requires solving a non-convex optimization problem in the same search space. In order to scale the method and keep its benefits, we propose an algorithm (LineBO) that restricts the problem to a sequence of iteratively chosen one-dimensional sub-problems that can be solved efficiently. We show t…
▽ More
Bayesian optimization is known to be difficult to scale to high dimensions, because the acquisition step requires solving a non-convex optimization problem in the same search space. In order to scale the method and keep its benefits, we propose an algorithm (LineBO) that restricts the problem to a sequence of iteratively chosen one-dimensional sub-problems that can be solved efficiently. We show that our algorithm converges globally and obtains a fast local rate when the function is strongly convex. Further, if the objective has an invariant subspace, our method automatically adapts to the effective dimension without changing the algorithm. When combined with the SafeOpt algorithm to solve the sub-problems, we obtain the first safe Bayesian optimization algorithm with theoretical guarantees applicable in high-dimensional settings. We evaluate our method on multiple synthetic benchmarks, where we obtain competitive performance. Further, we deploy our algorithm to optimize the beam intensity of the Swiss Free Electron Laser with up to 40 parameters while satisfying safe operation constraints.
△ Less
Submitted 28 May, 2019; v1 submitted 8 February, 2019;
originally announced February 2019.
-
Opportunities in Machine Learning for Particle Accelerators
Authors:
Auralee Edelen,
Christopher Mayes,
Daniel Bowring,
Daniel Ratner,
Andreas Adelmann,
Rasmus Ischebeck,
Jochem Snuverink,
Ilya Agapov,
Raimund Kammering,
Jonathan Edelen,
Ivan Bazarov,
Gianluca Valentino,
Jorg Wenninger
Abstract:
Machine learning (ML) is a subfield of artificial intelligence. The term applies broadly to a collection of computational algorithms and techniques that train systems from raw data rather than a priori models. ML techniques are now technologically mature enough to be applied to particle accelerators, and we expect that ML will become an increasingly valuable tool to meet new demands for beam energ…
▽ More
Machine learning (ML) is a subfield of artificial intelligence. The term applies broadly to a collection of computational algorithms and techniques that train systems from raw data rather than a priori models. ML techniques are now technologically mature enough to be applied to particle accelerators, and we expect that ML will become an increasingly valuable tool to meet new demands for beam energy, brightness, and stability. The intent of this white paper is to provide a high-level introduction to problems in accelerator science and operation where incorporating ML-based approaches may provide significant benefit. We review ML techniques currently being investigated at particle accelerator facilities, and we place specific emphasis on active research efforts and promising exploratory results. We also identify new applications and discuss their feasibility, along with the required data and infrastructure strategies. We conclude with a set of guidelines and recommendations for laboratory managers and administrators, emphasizing the logistical and technological requirements for successfully adopting this technology. This white paper also serves as a summary of the discussion from a recent workshop held at SLAC on ML for particle accelerators.
△ Less
Submitted 7 November, 2018;
originally announced November 2018.
-
Generation and Measurement of Sub-Micrometer Relativistic Electron Beams
Authors:
Simona Borrelli,
Gian Luca Orlandi,
Martin Bednarzik,
Christian David,
Eugenio Ferrari,
Vitaliy A. Guzenko,
Cigdem Ozkan-Loch,
Eduard Prat,
Rasmus Ischebeck
Abstract:
The generation of low-emittance electron beams has received significant interest in recent years. Driven by the requirements of X-ray free electron lasers, the emittance of photocathode injectors has been reduced significantly, with a corresponding increase in beam brightness. At the same time, this has put increasingly stringent requirements on the instrumentation to measure the beam size. These…
▽ More
The generation of low-emittance electron beams has received significant interest in recent years. Driven by the requirements of X-ray free electron lasers, the emittance of photocathode injectors has been reduced significantly, with a corresponding increase in beam brightness. At the same time, this has put increasingly stringent requirements on the instrumentation to measure the beam size. These requirements are even more stringent for novel accelerator developments, such as laser-driven accelerators based on dielectric structures or on a plasma, or for linear colliders at the energy frontier. We present here the generation and measurement of a sub-micrometer electron beam, at a particle energy of 330 MeV, and a bunch charge below 1 pC. An electron beam optics with a beta-function of a few millimeters in the vertical plane had been set up. The beam was characterized through a wire scanner that employs a 1 um wide metallic structure fabricated using the electron beam lithography on a silicon nitride membrane. The smallest (rms) beam size presented here is less than 500 nm.
△ Less
Submitted 11 April, 2018;
originally announced April 2018.
-
Energy efficiency studies for dual-grating dielectric laser-driven accelerators
Authors:
Yelong Wei,
Mark Ibison,
Javier Resta-Lopez,
Carsten Welsch,
Rasmus Ischebeck,
Steven Jamison,
Guoxing Xia,
Micha Dehler,
Eduard Prat,
Jonathan Smith
Abstract:
Dielectric laser-driven accelerators (DLAs) can provide high accelerating gradients in the GV/m range due to their having higher breakdown thresholds than metals, which opens the way for the miniaturization of the next generation of particle accelerator facilities. Two kinds of scheme, the addition of a Bragg reflector and the use of pulse-front-tilted (PFT) laser illumination, have been studied s…
▽ More
Dielectric laser-driven accelerators (DLAs) can provide high accelerating gradients in the GV/m range due to their having higher breakdown thresholds than metals, which opens the way for the miniaturization of the next generation of particle accelerator facilities. Two kinds of scheme, the addition of a Bragg reflector and the use of pulse-front-tilted (PFT) laser illumination, have been studied separately to improve the energy efficiency for dual-grating DLAs. The Bragg reflector enhances the accelerating gradient of the structure, while the PFT increases the effective interaction length. In this paper, we investigate numerically the advantages of using the two schemes in conjunction. Our calculations show that, for a 100-period structure with a period of 2 micrometer, such a design effectively increases the energy gain by more than 100 % when compared to employing the Bragg reflector with a normal laser, and by about 50 % when using standard structures with a PFT laser. A total energy gain of as much as 2.6 MeV can be obtained for a PFT laser beam when illuminating a 2000-period dual-grating structure with a Bragg reflector.
△ Less
Submitted 13 December, 2017;
originally announced December 2017.
-
Realtime Tomography of Gas-Jets with a Wollaston Interferometer
Authors:
A. Adelmann,
B. Hermann,
R. Ischebeck,
M. C. Kaluza,
U. Locans,
N. Sauerwein,
R. Tarkeshian
Abstract:
A tomographic gas-density diagnostic using a single-beam Wollaston interferometer able to characterise non-symmetric density distributions in gas jets is presented. A real-time tomographic algorithm is able to reconstruct three dimensional density distributions. A Maximum Likelihood -- Expectation Maximisation algorithm, an iterative method with good convergence properties compared to simple back…
▽ More
A tomographic gas-density diagnostic using a single-beam Wollaston interferometer able to characterise non-symmetric density distributions in gas jets is presented. A real-time tomographic algorithm is able to reconstruct three dimensional density distributions. A Maximum Likelihood -- Expectation Maximisation algorithm, an iterative method with good convergence properties compared to simple back projection, is used. With the use of graphical processing units, real time computation and high resolution are achieved. Two different gas jets are characterised: a kHz, piezo-driven jet for lower densities and a solenoid valve based jet producing higher densities. While the first is planned for to be used in bunch length monitors at the free electron laser at Paul Scherrer Institut (PSI, SwissFEL), the second jet is planned to be used for laser wakefield acceleration experiments, exploring the linear regime. In this latter application, well-tailored and non-symmetric density distributions produced by a supersonic shock front generated by a razor blade inserted laterally to the gas flow, which breaks cylindrical symmetry, need to be characterized.
△ Less
Submitted 23 February, 2018; v1 submitted 7 November, 2017;
originally announced November 2017.
-
Design and Test of Wire-Scanners for SwissFEL
Authors:
G. L. Orlandi,
M. Baldinger,
H. Brands,
P. Heimgartner,
R. Ischebeck,
A. Kammerer,
F. Löhl,
R. Lüscher,
P. Mohanmurthy,
C. Ozkan,
V. Schlott,
L. Schulz,
B. Rippstein,
C. Seiler,
S. Trovati,
P. Valitutti,
D. Zimoch
Abstract:
The SwissFEL light-facility will provide coherent X-rays in the wavelength region 7-0.7 nm and 0.7-0.1 nm. In SwissFEL, view-screens and wire-scanners will be used to monitor the transverse profile of a 200/10pC electron beam with a normalized emittance of 0.4/0.2 mm.mrad and a final energy of 5.8 GeV. Compared to view screens, wire-scanners offer a quasi-non-destructive monitoring of the beam tra…
▽ More
The SwissFEL light-facility will provide coherent X-rays in the wavelength region 7-0.7 nm and 0.7-0.1 nm. In SwissFEL, view-screens and wire-scanners will be used to monitor the transverse profile of a 200/10pC electron beam with a normalized emittance of 0.4/0.2 mm.mrad and a final energy of 5.8 GeV. Compared to view screens, wire-scanners offer a quasi-non-destructive monitoring of the beam transverse profile without suffering from possible micro-bunching of the electron beam. The main aspects of the design, laboratory characterization and beam-test of the SwissFEL wire-scanner prototype will be discussed.
△ Less
Submitted 1 November, 2016;
originally announced November 2016.
-
Commissioning experience and beam physics measurements at the SwissFEL Injector Test Facility
Authors:
T. Schietinger,
M. Pedrozzi,
M. Aiba,
V. Arsov,
S. Bettoni,
B. Beutner,
M. Calvi,
P. Craievich,
M. Dehler,
F. Frei,
R. Ganter,
C. P. Hauri,
R. Ischebeck,
Y. Ivanisenko,
M. Janousch,
M. Kaiser,
B. Keil,
F. Löhl,
G. L. Orlandi,
C. Ozkan Loch,
P. Peier,
E. Prat,
J. -Y. Raguin,
S. Reiche,
T. Schilcher
, et al. (70 additional authors not shown)
Abstract:
The SwissFEL Injector Test Facility operated at the Paul Scherrer Institute between 2010 and 2014, serving as a pilot plant and testbed for the development and realization of SwissFEL, the X-ray Free-Electron Laser facility under construction at the same institute. The test facility consisted of a laser-driven rf electron gun followed by an S-band booster linac, a magnetic bunch compression chican…
▽ More
The SwissFEL Injector Test Facility operated at the Paul Scherrer Institute between 2010 and 2014, serving as a pilot plant and testbed for the development and realization of SwissFEL, the X-ray Free-Electron Laser facility under construction at the same institute. The test facility consisted of a laser-driven rf electron gun followed by an S-band booster linac, a magnetic bunch compression chicane and a diagnostic section including a transverse deflecting rf cavity. It delivered electron bunches of up to 200 pC charge and up to 250 MeV beam energy at a repetition rate of 10 Hz. The measurements performed at the test facility not only demonstrated the beam parameters required to drive the first stage of an FEL facility, but also led to significant advances in instrumentation technologies, beam characterization methods and the generation, transport and compression of ultra-low-emittance beams. We give a comprehensive overview of the commissioning experience of the principal subsystems and the beam physics measurements performed during the operation of the test facility, including the results of the test of an in-vacuum undulator prototype generating radiation in the vacuum ultraviolet and optical range.
△ Less
Submitted 27 October, 2016; v1 submitted 8 June, 2016;
originally announced June 2016.
-
Test Results on the Silicon Pixel Detector for the TTF-FEL Beam Trajectory Monitor
Authors:
S. Hillert,
R. Ischebeck,
U. C. Müller,
S. Roth,
K. Hansen,
P. Holl,
S. Karstensen,
J. Kemmer,
R. Klanner,
P. Lechner,
M. Leenen,
J. S. T. Ng,
P. Schmüser,
L. Strüder
Abstract:
Test measurements on the silicon pixel detector for the beam trajectory monitor at the free electron laser of the TESLA test facility are presented. To determine the electronic noise of detector and read-out and to calibrate the signal amplitude of different pixels the 6 keV photons of the manganese K line are used. Two different methods determine the spatial accuracy of the detector: In one set…
▽ More
Test measurements on the silicon pixel detector for the beam trajectory monitor at the free electron laser of the TESLA test facility are presented. To determine the electronic noise of detector and read-out and to calibrate the signal amplitude of different pixels the 6 keV photons of the manganese K line are used. Two different methods determine the spatial accuracy of the detector: In one setup a laser beam is focused to a straight line and moved across the pixel structure. In the other the detector is scanned using a low-intensity electron beam of an electron microscope. Both methods show that the symmetry axis of the detector defines a straight line within 0.4 microns. The sensitivity of the detector to low energy X-rays is measured using a vacuum ultraviolet beam at the synchrotron light source HASYLAB. Additionally, the electron microscope is used to study the radiation hardness of the detector.
△ Less
Submitted 25 April, 2000;
originally announced April 2000.