Speed, power and cost implications for GPU acceleration of Computational Fluid Dynamics on HPC systems
Authors:
Zachary Cooper-Baldock,
Brenda Vara Almirall,
Kiao Inthavong
Abstract:
Computational Fluid Dynamics (CFD) is the simulation of fluid flow undertaken with the use of computational hardware. The underlying equations are computationally challenging to solve and necessitate high performance computing (HPC) to resolve in a practical timeframe when a reasonable level of fidelity is required. The simulations are memory intensive, having previously been limited to central pr…
▽ More
Computational Fluid Dynamics (CFD) is the simulation of fluid flow undertaken with the use of computational hardware. The underlying equations are computationally challenging to solve and necessitate high performance computing (HPC) to resolve in a practical timeframe when a reasonable level of fidelity is required. The simulations are memory intensive, having previously been limited to central processing unit (CPU) solvers, as graphics processing unit (GPU) video random access memory (VRAM) was insufficient. However, with recent developments in GPU design and increases to VRAM, GPU acceleration of CPU solved workflows is now possible. At HPC scale however, many operational details are still unknown. This paper utilizes ANSYS Fluent, a leading commercial code in CFD, to investigate the compute speed, power consumption and service unit (SU) cost considerations for the GPU acceleration of CFD workflows on HPC architectures. To provide a comprehensive analysis, different CPU architectures, and GPUs have been assessed. It is seen that GPU compute speed is faster, however, the initialisation speed, power and cost performance is less clear cut. Whilst the larger A100 cards perform well with respect to power consumption, this is not observed for the V100 cards. In situations where more than one GPU is required, their adoption may not be beneficial from a power or cost perspective.
△ Less
Submitted 3 April, 2024;
originally announced April 2024.
-
Primary spray break-up from a nasal spray atomizer using Volume of Fluid to Discrete Phase Model
Authors:
Kendra Shrestha,
James Van Strien,
David F Fletcher,
Kiao Inthavong
Abstract:
Spray atomization process involves complex multi-phase phenomena. Abundant literature and validation of spray modelling for industrial applications like fuel injection in internal combustion and turbine jet engines are available. However, only a handful of studies, primarily limited to discrete phase modelling, of low-pressure applications, such as nasal spray exists. This study aims to provide in…
▽ More
Spray atomization process involves complex multi-phase phenomena. Abundant literature and validation of spray modelling for industrial applications like fuel injection in internal combustion and turbine jet engines are available. However, only a handful of studies, primarily limited to discrete phase modelling, of low-pressure applications, such as nasal spray exists. This study aims to provide insight into the external and near-nozzle spray characterization of a continuous spray and establishes good validation against the experiment. A 3-dimensional (3D) X-ray scanner was used to extract the internal nasal spray nozzle geometry which was reconstructed to build a 3D computational model. A novel volume-of-fluid to discrete phase transition model (VOF-DPM) was used to track the liquid phase and its transition to droplets, which was based on the shape and size of the liquid lumps. In this study, an early pre-stable and stable phase of spray plume development was investigated. Qualitative and quantitative analysis were carried out to validate the computational model. A liquid column exited a nozzle which distorted at its base with advancement in time and eventually formed a hollow-cone liquid sheet. It then, disintegrated due to instability that produced fluctuations to form ligaments resulting in secondary break-up. This study provides in-depth understanding of liquid jet disintegration and droplet formation, which adds value to future nasal spray device designs and techniques to facilitate more effective targeted nasal drug delivery.
△ Less
Submitted 2 May, 2023;
originally announced May 2023.
-
Enhancing respiratory comfort with fan respirators: computational analysis of carbon dioxide reduction, temperature regulation, and humidity control
Authors:
Hana Salati,
Patrick Warfield-McAlpine,
David F Fletcher,
Kiao Inthavong
Abstract:
Respirators provide protection from inhalation exposure to dangerous substances, such as chemicals and infectious particles, including SARS-Covid-laden droplets and aerosols. However, they are prone to exposure to stale air as the masks creat a microclimate influenced by the exhaled air. As a result, exhaled air from the lungs accumulating in the mask produce a warm and humid environment that has…
▽ More
Respirators provide protection from inhalation exposure to dangerous substances, such as chemicals and infectious particles, including SARS-Covid-laden droplets and aerosols. However, they are prone to exposure to stale air as the masks creat a microclimate influenced by the exhaled air. As a result, exhaled air from the lungs accumulating in the mask produce a warm and humid environment that has a high concentration of carbon dioxide (CO2), unsuitable for re-inhalation. Fans are a favourable option for respirators to ventilate the mask and remove the stale air. This study utilized computational fluid dynamics simulation consisting of a hybrid Reynolds-averaged Navier-Stokes (RANS)-large eddy simulation (LES) turbulence method to compare the inhalation flow properties for different fan locations (bottom, top, and side) with regular respirator breathing. Three mask positions, top, side, and bottom, were evaluated under two breathing cycles (approximately 9.65s of breathing time). The results demonstrated that adding a fan respirator significantly decreased internal mask temperature, humidity, and CO2 concentration. The average CO2 concentration decreased by 87%, 67% and 73% for locations bottom, top and side respectively. Whilst the top and side fan locations enhanced the removal of the exhaled gas mixture, the bottom-fan respirator was more efficient in removing the nostril jet gas mixture and therefore provided the least barrier to respiratory function. The results provide valuable insights into the benefits of fan respirators for long-term use for reducing CO2 concentration, mask temperature, and humidity, improving wearer safety and comfort in hazardous environments, especially during the COVID-19 pandemic.
△ Less
Submitted 2 May, 2023;
originally announced May 2023.
-
Nasal irrigation delivery in three post-FESS models from a squeeze-bottle using CFD
Authors:
Hana Salati,
Narinder Singh,
Mehrdad Khamooshi,
Sara Vahaji,
David F. Fletcher,
Kiao Inthavong
Abstract:
Purpose: Nasal saline irrigation is highly recommended in patients following functional endoscopic sinus surgery (FESS) to aid the postoperative recovery. Post-FESS patients have significantly altered anatomy leading to markedly different flow dynamics from those found in pre-op or non-diseased airways, resulting in unknown flow dynamics. Methods: This work investigated how the liquid stream dispe…
▽ More
Purpose: Nasal saline irrigation is highly recommended in patients following functional endoscopic sinus surgery (FESS) to aid the postoperative recovery. Post-FESS patients have significantly altered anatomy leading to markedly different flow dynamics from those found in pre-op or non-diseased airways, resulting in unknown flow dynamics. Methods: This work investigated how the liquid stream disperses through altered nasal cavities following surgery using Computational Fluid Dynamics (CFD). A realistic squeeze profile was determined from physical experiments with a 27-year-old male using a squeeze bottle with load sensors. The administration technique involved a head tilt of 45-degrees forward to represent a head position over a sink. After the irrigation event that lasted 4.5 s, the simulation continued for an additional 1.5 s, with the head orientation returning to an upright position. Results: The results demonstrated that a large maxillary sinus ostium on the right side allows saline penetration into this sinus. The increased volume of saline entering the maxillary sinus limits the saline volume available to the rest of the sinonasal cavity and reduces the surface coverage of the other paranasal sinuses. The average wall shear stress was higher on the right side than on the other side for two patients. The results also revealed that head position alters the sinuses saline residual, especially the frontal sinuses. Conclusion: While greater access to sinuses is achieved through FESS surgery, patients without a nasal septum limits posterior sinus penetration due to the liquid crossing over to the contralateral cavity and exiting the nasal cavity early.
△ Less
Submitted 18 August, 2022;
originally announced August 2022.
-
Spray characteristics from nasal spray atomization
Authors:
James Van Strien,
Phred Petersen,
Petros Lappas,
Leslie Yeo,
Amgad Rezk,
Sara Vahaji,
Kiao Inthavong
Abstract:
In addition to topical delivery, nasal sprays offer an alternative drug administration route to the systemic circulation, therefore avoiding the need for painful, invasive delivery techniques. Studies on the efficacy of nasal drug delivery to date have been conflicting despite its potential. In particular computational studies, e.g. Computational Fluid Dynamics (CFD), of nasal spray deposition req…
▽ More
In addition to topical delivery, nasal sprays offer an alternative drug administration route to the systemic circulation, therefore avoiding the need for painful, invasive delivery techniques. Studies on the efficacy of nasal drug delivery to date have been conflicting despite its potential. In particular computational studies, e.g. Computational Fluid Dynamics (CFD), of nasal spray deposition require realistic initial spray conditions, which are lacking in the literature. This study aims to provide benchmark experimental data for CFD inputs by characterising four different types of commercially available nasal sprays used in an ENT (Ear Nose Throat) clinic. Spray characteristics were obtained via high-speed videography, while droplet size distribution (DSD) measurements were obtained with laser diffraction. Three actuation forces were evaluated, representing the use-case of an average adult, average child and the maximum force applied to the spray device. The results demonstrated that actuation force influenced spray velocity, spray duration, DSD, and breakup length. Quantitative data of Rosin-Rammler diameter distributions, spray cone angles, dispersion angles and breakup lengths were found, assisting computational models with realistic values, thereby improving future CFD studies of nasal spray drug delivery in the nasal cavity.
△ Less
Submitted 3 May, 2022;
originally announced May 2022.
-
Inhalation and deposition of spherical and pollen particles after middle turbinate resection in a human nasal cavity
Authors:
Kiao Inthavong,
Yidan Shang,
John M. Del Gaudio,
Sarah K. Wise,
Thomas S. Edwards,
Kimberley Bradshaw,
Eugene Wong,
Murray Smith,
Narinder Singh
Abstract:
Middle turbinate resection significantly alters the anatomy and redistributes the inhaled air. The superior half of the main nasal cavity is opened up, increasing accessibility to the region. This is expected to increase inhalation dosimetry to the region during exposure to airborne particles. This study investigated the influence of middle turbinate resection on the deposition of inhaled pollutan…
▽ More
Middle turbinate resection significantly alters the anatomy and redistributes the inhaled air. The superior half of the main nasal cavity is opened up, increasing accessibility to the region. This is expected to increase inhalation dosimetry to the region during exposure to airborne particles. This study investigated the influence of middle turbinate resection on the deposition of inhaled pollutants that cover spherical and non-spherical particles (e.g. pollen). A computational model of the nasal cavity from CT scans, and its corresponding post-operative model with virtual surgery performed was created. Two constant flow rates of 5_L/min, and 15_L/min were simulated under a laminar flow field. Inhaled particles including pollen (non-spherical), and a spherical particle with reference density of 1000 kg/m3 were introduced in the surrounding atmosphere. The effect of surgery was most prominent in the less patent cavity side, since the change in anatomy was proportionally greater relative to the original airway space. The left cavity produced an increase in particle deposition at a flow rate of 15_L/min. The main particle deposition mechanisms were inertial impaction, and to a lesser degree gravitational sedimentation. The results are expected to provide insight into inhalation efficiency of different aerosol types, and the likelihood of deposition in different nasal cavity surfaces.
△ Less
Submitted 8 August, 2021;
originally announced August 2021.
-
Sedimentation effects on particle position and inertial deposition in 90° circular bends
Authors:
Sara Vahaji,
Ngoc-Hien Nguyen,
Yidan Shang,
Kiao Inthavong
Abstract:
Laminar fluid-particle flows in bend geometries are present in many industrial, pharmaceutical, and biomedical applications. Particle deposition has been studied extensively; however, little attention has been paid to the effect of particle sedimentation on particle position and deposition in different pipe geometry combinations. This study presented a comprehensive analysis of sedimentation effec…
▽ More
Laminar fluid-particle flows in bend geometries are present in many industrial, pharmaceutical, and biomedical applications. Particle deposition has been studied extensively; however, little attention has been paid to the effect of particle sedimentation on particle position and deposition in different pipe geometry combinations. This study presented a comprehensive analysis of sedimentation effects on particle flow behaviour in 90° circular pipe bends of micron particles in laminar pipe flows. Pipe geometry combinations consisted of eight pipe diameters, nine bend radii, and 30 particle diameters in a range of 1 to 100 μm. The results demonstrated the locations of particles that sedimented to the bottom half of the straight pipe section, and the particle positions upstream from the pipe bend entrance, which was no longer in a fully developed profile. These new locations represent the effects of gravity, pulling the particles down. While obtaining these positions can be found through CFD analysis, we proposed an analytical solution to predict the particle trajectory from different release locations that would help to identify the initial particle distribution at locations upstream to the bend, to obviate the need for long upstream straight pipe sections in the CFD analysis.
△ Less
Submitted 19 August, 2021; v1 submitted 6 August, 2021;
originally announced August 2021.
-
Pressure distribution and flow dynamics in a nasal airway using a scale resolving simulation
Authors:
James Van Strien,
Kendra Shrestha,
Sargon Gabriel,
Petros Lappas,
David F. Fletcher,
Narinder Singh,
Kiao Inthavong
Abstract:
Airflow through the nasal cavity exhibits a wide variety of fluid dynamicsbehaviour due to the intricacy of the nasal geometry. The flow is naturallyunsteady and perhaps turbulent, despite CFD in the literature that assumesa steady laminar flow. Time-dependent simulations can be used to generatedetailed data with the potential to uncover new flow behaviour, although theyare more computationally in…
▽ More
Airflow through the nasal cavity exhibits a wide variety of fluid dynamicsbehaviour due to the intricacy of the nasal geometry. The flow is naturallyunsteady and perhaps turbulent, despite CFD in the literature that assumesa steady laminar flow. Time-dependent simulations can be used to generatedetailed data with the potential to uncover new flow behaviour, although theyare more computationally intensive compared with steady-state simulations. Furthermore, verification of CFD results has relied on reported pressure drop(e.g. nasal resistance) across the nasal airway although the geometries usedare different. This study investigated the unsteady nature of inhalation atflow rates of 10, 15, 20, and 30 L/min. A scale resolving CFD simulationusing a hybrid RANS-LES model was used and compared with experimentalmeasurements of the pressure distribution and the overall pressure drop in thenasal cavity. The experimental results indicated a large pressure drop acrossthe nasal valve, as well as across the nasopharynx with the latter attributedto a narrow cross-sectional area. At a flowrate of 30 L/min, the CFD simula-tions showed that the anterior half of the nasal cavity displayed dominantlylaminar but disturbed flow behaviour in the form of velocity fluctuations. Theposterior half of the nasal cavity displayed turbulent activity, characterised byerratic fluctuating velocities, which was enhanced by the wider cross-sectionalareas in the coronal plane. At 15L/min, the flow field was laminar dominantwith very little disturbance confirming a steady-state laminar flow assumptionis viable at this flow rate.
△ Less
Submitted 28 July, 2021;
originally announced July 2021.
-
The impact of nasal adhesions on airflow and mucosal cooling -- a computational fluid dynamics analysis
Authors:
Praween Senanayakea,
Hana Salati,
Eugene Wong,
Kimberley Bradshaw,
Yidan Shang,
Narinder Singh,
Kiao Inthavong
Abstract:
Nasal adhesions are a known postoperative complication following surgical procedures for nasal airway obstruction (NAO); and are a common cause of surgical failure, with patients often reporting significant NAO, despite relatively minor adhesion size. Division of such nasal adhesions often provides much greater relief than anticipated, based on the minimal reduction in cross-sectional area associa…
▽ More
Nasal adhesions are a known postoperative complication following surgical procedures for nasal airway obstruction (NAO); and are a common cause of surgical failure, with patients often reporting significant NAO, despite relatively minor adhesion size. Division of such nasal adhesions often provides much greater relief than anticipated, based on the minimal reduction in cross-sectional area associated with the adhesion. The available literature regarding nasal adhesions provides little evidence examining their quantitative and qualitative effects on nasal airflow using objective measures. This study examined the impact of nasal adhesions at various anatomical sites on nasal airflow and mucosal cooling using computational fluid dynamics (CFD). A high-resolution CT scan of the paranasal sinuses of a 25-year-old, healthy female patient was segmented to create a three-dimensional nasal airway model. Virtual nasal adhesions of 2.5~mm diameter were added to various locations within the nasal cavity, representing common sites seen following NAO surgery. A series of models with single adhesions were created. CFD analysis was performed on each model and compared with a baseline no-adhesion model, comparing airflow and heat and mass transfer. The nasal adhesions resulted in no significant change in bulk airflow patterns through the nasal cavity. However, significant changes were observed in local airflow and mucosal cooling around and immediately downstream to the nasal adhesions. These were most evident with anterior nasal adhesions at the internal valve and anterior inferior turbinate.
△ Less
Submitted 8 July, 2021;
originally announced July 2021.