-
FAMU: study of the energy dependent transfer rate $Λ_{μp \rightarrow μO}$
Authors:
FAMU Collaboration,
E. Mocchiutti,
V. Bonvicini,
M. Danailov,
E. Furlanetto,
K. S. Gadedjisso-Tossou,
D. Guffanti,
C. Pizzolotto,
A. Rachevski,
L. Stoychev,
E. Vallazza,
G. Zampa,
J. Niemela,
K. Ishida,
A. Adamczak,
G. Baccolo,
R. Benocci,
R. Bertoni,
M. Bonesini,
F. Chignoli,
M. Clemenza,
A. Curioni,
V. Maggi,
R. Mazza,
M. Moretti
, et al. (31 additional authors not shown)
Abstract:
The main goal of the FAMU experiment is the measurement of the hyperfine splitting (hfs) in the 1S state of muonic hydrogen $ΔE_{hfs}(μ^-p)1S$. The physical process behind this experiment is the following: $μp$ are formed in a mixture of hydrogen and a higher-Z gas. When absorbing a photon at resonance-energy $ΔE_{hfs}\approx0.182$~eV, in subsequent collisions with the surrounding $H_2$ molecules,…
▽ More
The main goal of the FAMU experiment is the measurement of the hyperfine splitting (hfs) in the 1S state of muonic hydrogen $ΔE_{hfs}(μ^-p)1S$. The physical process behind this experiment is the following: $μp$ are formed in a mixture of hydrogen and a higher-Z gas. When absorbing a photon at resonance-energy $ΔE_{hfs}\approx0.182$~eV, in subsequent collisions with the surrounding $H_2$ molecules, the $μp$ is quickly de-excited and accelerated by $\sim2/3$ of the excitation energy. The observable is the time distribution of the K-lines X-rays emitted from the $μZ$ formed by muon transfer $(μp) +Z \rightarrow (μZ)^*+p$, a reaction whose rate depends on the $μp$ kinetic energy. The maximal response, to the tuned laser wavelength, of the time distribution of X-ray from K-lines of the $(μZ)^*$ cascade indicate the resonance. During the preparatory phase of the FAMU experiment, several measurements have been performed both to validate the methodology and to prepare the best configuration of target and detectors for the spectroscopic measurement. We present here the crucial study of the energy dependence of the transfer rate from muonic hydrogen to oxygen ($Λ_{μp \rightarrow μO}$), precisely measured for the first time.
△ Less
Submitted 22 January, 2019; v1 submitted 20 August, 2018;
originally announced August 2018.
-
First FAMU observation of muon transfer from mu-p atoms to higher-Z elements
Authors:
FAMU Collaboration,
Emiliano Mocchiutti,
Valter Bonvicini,
Rita Carbone,
Miltcho Danailov,
Elena Furlanetto,
Komlan Segbeya Gadedjisso-Tossou,
Daniele Guffanti,
Cecilia Pizzolotto,
Alexandre Rachevski,
Lyubomir Stoychev,
Erik Silvio Vallazza,
Gianluigi Zampa,
Joseph Niemela,
Katsuhiko Ishida,
Andrzej Adamczak,
Giovanni Baccolo,
Roberto Benocci,
Roberto Bertoni,
Maurizio Bonesini,
Francesco Chignoli,
Massimiliano Clemenza,
Alessandro Curioni,
Valter Maggi,
Roberto Mazza
, et al. (32 additional authors not shown)
Abstract:
The FAMU experiment aims to accurately measure the hyperfine splitting of the ground state of the muonic hydrogen atom. A measurement of the transfer rate of muons from hydrogen to heavier gases is necessary for this purpose. In June 2014, within a preliminary experiment, a pressurized gas-target was exposed to the pulsed low-energy muon beam at the RIKEN RAL muon facility (Rutherford Appleton Lab…
▽ More
The FAMU experiment aims to accurately measure the hyperfine splitting of the ground state of the muonic hydrogen atom. A measurement of the transfer rate of muons from hydrogen to heavier gases is necessary for this purpose. In June 2014, within a preliminary experiment, a pressurized gas-target was exposed to the pulsed low-energy muon beam at the RIKEN RAL muon facility (Rutherford Appleton Laboratory, UK). The main goal of the test was the characterization of both the noise induced by the pulsed beam and the X-ray detectors. The apparatus, to some extent rudimental, has served admirably to this task. Technical results have been published that prove the validity of the choices made and pave the way for the next steps. This paper presents the results of physical relevance of measurements of the muon transfer rate to carbon dioxide, oxygen, and argon from non-thermalized excited mu-p atoms. The analysis methodology and the approach to the systematics errors are useful for the subsequent study of the transfer rate as function of the kinetic energy of the mu-p currently under way.
△ Less
Submitted 15 December, 2017; v1 submitted 10 August, 2017;
originally announced August 2017.
-
Steps towards the hyperfine splitting measurement of the muonic hydrogen ground state: pulsed muon beam and detection system characterization
Authors:
A. Adamczak,
G. Baccolo,
D. Bakalov,
G. Baldazzi,
R. Bertoni,
M. Bonesini,
V. Bonvicini,
R. Campana,
R. Carbone,
T. Cervi,
F. Chignoli,
M. Clemenza,
L. Colace,
A. Curioni,
M. Danailov,
P. Danev,
I. D'Antone,
A. De,
C. De,
M. De,
M. Furini,
F. Fuschino,
K. Gadejisso-Tossou,
D. Guffanti,
A. Iaciofano
, et al. (30 additional authors not shown)
Abstract:
The high precision measurement of the hyperfine splitting of the muonic-hydrogen atom ground state with pulsed and intense muon beam requires careful technological choices both in the construction of a gas target and of the detectors. In June 2014, the pressurized gas target of the FAMU experiment was exposed to the low energy pulsed muon beam at the RIKEN RAL muon facility. The objectives of the…
▽ More
The high precision measurement of the hyperfine splitting of the muonic-hydrogen atom ground state with pulsed and intense muon beam requires careful technological choices both in the construction of a gas target and of the detectors. In June 2014, the pressurized gas target of the FAMU experiment was exposed to the low energy pulsed muon beam at the RIKEN RAL muon facility. The objectives of the test were the characterization of the target, the hodoscope and the X-ray detectors. The apparatus consisted of a beam hodoscope and X-rays detectors made with high purity Germanium and Lanthanum Bromide crystals. In this paper the experimental setup is described and the results of the detector characterization are presented.
△ Less
Submitted 21 June, 2016; v1 submitted 6 April, 2016;
originally announced April 2016.
-
Pion contamination in the MICE muon beam
Authors:
D. Adams,
A. Alekou,
M. Apollonio,
R. Asfandiyarov,
G. Barber,
P. Barclay,
A. de Bari,
R. Bayes,
V. Bayliss,
R. Bertoni,
V. J. Blackmore,
A. Blondel,
S. Blot,
M. Bogomilov,
M. Bonesini,
C. N. Booth,
D. Bowring,
S. Boyd,
T. W. Bradshaw,
U. Bravar,
A. D. Bross,
M. Capponi,
T. Carlisle,
G. Cecchet,
C. Charnley
, et al. (120 additional authors not shown)
Abstract:
The international Muon Ionization Cooling Experiment (MICE) will perform a systematic investigation of ionization cooling with muon beams of momentum between 140 and 240\,MeV/c at the Rutherford Appleton Laboratory ISIS facility. The measurement of ionization cooling in MICE relies on the selection of a pure sample of muons that traverse the experiment. To make this selection, the MICE Muon Beam i…
▽ More
The international Muon Ionization Cooling Experiment (MICE) will perform a systematic investigation of ionization cooling with muon beams of momentum between 140 and 240\,MeV/c at the Rutherford Appleton Laboratory ISIS facility. The measurement of ionization cooling in MICE relies on the selection of a pure sample of muons that traverse the experiment. To make this selection, the MICE Muon Beam is designed to deliver a beam of muons with less than $\sim$1\% contamination. To make the final muon selection, MICE employs a particle-identification (PID) system upstream and downstream of the cooling cell. The PID system includes time-of-flight hodoscopes, threshold-Cherenkov counters and calorimetry. The upper limit for the pion contamination measured in this paper is $f_π< 1.4\%$ at 90\% C.L., including systematic uncertainties. Therefore, the MICE Muon Beam is able to meet the stringent pion-contamination requirements of the study of ionization cooling.
△ Less
Submitted 10 February, 2016; v1 submitted 2 November, 2015;
originally announced November 2015.
-
Electron-Muon Ranger: performance in the MICE Muon Beam
Authors:
D. Adams,
A. Alekou,
M. Apollonio,
R. Asfandiyarov,
G. Barber,
P. Barclay,
A. de Bari,
R. Bayes,
V. Bayliss,
P. Bene,
R. Bertoni,
V. J. Blackmore,
A. Blondel,
S. Blot,
M. Bogomilov,
M. Bonesini,
C. N. Booth,
D. Bowring,
S. Boyd,
T. W. Bradshaw,
U. Bravar,
A. D. Bross,
F. Cadoux,
M. Capponi,
T. Carlisle
, et al. (129 additional authors not shown)
Abstract:
The Muon Ionization Cooling Experiment (MICE) will perform a detailed study of ionization cooling to evaluate the feasibility of the technique. To carry out this program, MICE requires an efficient particle-identification (PID) system to identify muons. The Electron-Muon Ranger (EMR) is a fully-active tracking-calorimeter that forms part of the PID system and tags muons that traverse the cooling c…
▽ More
The Muon Ionization Cooling Experiment (MICE) will perform a detailed study of ionization cooling to evaluate the feasibility of the technique. To carry out this program, MICE requires an efficient particle-identification (PID) system to identify muons. The Electron-Muon Ranger (EMR) is a fully-active tracking-calorimeter that forms part of the PID system and tags muons that traverse the cooling channel without decaying. The detector is capable of identifying electrons with an efficiency of 98.6%, providing a purity for the MICE beam that exceeds 99.8%. The EMR also proved to be a powerful tool for the reconstruction of muon momenta in the range 100-280 MeV/$c$.
△ Less
Submitted 3 November, 2015; v1 submitted 28 October, 2015;
originally announced October 2015.
-
Characterisation of the muon beams for the Muon Ionisation Cooling Experiment
Authors:
The MICE Collaboration,
D. Adams,
D. Adey,
A. Alekou,
M. Apollonio,
R. Asfandiyarov,
J. Back,
G. Barber,
P. Barclay,
A. de Bari,
R. Bayes,
V. Bayliss,
R. Bertoni,
V. J. Blackmore,
A. Blondel,
S. Blot,
M. Bogomilov,
M. Bonesini,
C. N. Booth,
D. Bowring,
S. Boyd,
T. W. Bradshaw,
U. Bravar,
A. D. Bross,
M. Capponi
, et al. (119 additional authors not shown)
Abstract:
A novel single-particle technique to measure emittance has been developed and used to characterise seventeen different muon beams for the Muon Ionisation Cooling Experiment (MICE). The muon beams, whose mean momenta vary from 171 to 281 MeV/c, have emittances of approximately 1.5--2.3 πmm-rad horizontally and 0.6--1.0 πmm-rad vertically, a horizontal dispersion of 90--190 mm and momentum spreads o…
▽ More
A novel single-particle technique to measure emittance has been developed and used to characterise seventeen different muon beams for the Muon Ionisation Cooling Experiment (MICE). The muon beams, whose mean momenta vary from 171 to 281 MeV/c, have emittances of approximately 1.5--2.3 πmm-rad horizontally and 0.6--1.0 πmm-rad vertically, a horizontal dispersion of 90--190 mm and momentum spreads of about 25 MeV/c. There is reasonable agreement between the measured parameters of the beams and the results of simulations. The beams are found to meet the requirements of MICE.
△ Less
Submitted 11 October, 2013; v1 submitted 6 June, 2013;
originally announced June 2013.
-
MICE: the Muon Ionization Cooling Experiment. Step I: First Measurement of Emittance with Particle Physics Detectors
Authors:
U. Bravar,
M. Bogomilov,
Y. Karadzhov,
D. Kolev,
I. Russinov,
R. Tsenov,
L. Wang,
F. Y. Xu,
S. X. Zheng,
R. Bertoni,
M. Bonesini,
R. Mazza,
V. Palladino,
G. Cecchet,
A. de Bari,
M. Capponi,
A. Iaciofano,
D. Orestano,
F. Pastore,
L. Tortora,
S. Ishimoto,
S. Suzuki,
K. Yoshimura,
Y. Mori,
Y. Kuno
, et al. (123 additional authors not shown)
Abstract:
The Muon Ionization Cooling Experiment (MICE) is a strategic R&D project intended to demonstrate the only practical solution to providing high brilliance beams necessary for a neutrino factory or muon collider. MICE is under development at the Rutherford Appleton Laboratory (RAL) in the United Kingdom. It comprises a dedicated beamline to generate a range of input muon emittances and momenta, with…
▽ More
The Muon Ionization Cooling Experiment (MICE) is a strategic R&D project intended to demonstrate the only practical solution to providing high brilliance beams necessary for a neutrino factory or muon collider. MICE is under development at the Rutherford Appleton Laboratory (RAL) in the United Kingdom. It comprises a dedicated beamline to generate a range of input muon emittances and momenta, with time-of-flight and Cherenkov detectors to ensure a pure muon beam. The emittance of the incoming beam will be measured in the upstream magnetic spectrometer with a scintillating fiber tracker. A cooling cell will then follow, alternating energy loss in Liquid Hydrogen (LH2) absorbers to RF cavity acceleration. A second spectrometer, identical to the first, and a second muon identification system will measure the outgoing emittance. In the 2010 run at RAL the muon beamline and most detectors were fully commissioned and a first measurement of the emittance of the muon beam with particle physics (time-of-flight) detectors was performed. The analysis of these data was recently completed and is discussed in this paper. Future steps for MICE, where beam emittance and emittance reduction (cooling) are to be measured with greater accuracy, are also presented.
△ Less
Submitted 30 July, 2013; v1 submitted 9 October, 2011;
originally announced October 2011.