-
Astronomical Spectroscopy with Skipper CCDs: First Results from a Skipper CCD Focal Plane Prototype at SIFS
Authors:
Edgar Marrufo Villalpando,
Alex Drlica-Wagner,
Brandon Roach,
Marco Bonati,
Abhishek Bakshi,
Julia Campa,
Gustavo Cancelo,
Braulio Cancino,
Claudio R. Chavez,
Fernando Chierchie,
Juan Estrada,
Guillermo Fernandez Moroni,
Luciano Fraga,
Manuel E. Gaido,
Stephen E. Holland,
Rachel Hur,
Michelle Jonas,
Peter Moore,
Eduardo Paolini,
Andrés A. Plazas Malagón,
Leandro Stefanazzi,
Javier Tiffenberg,
Ken Treptou,
Sho Uemura,
Neal Wilcer
Abstract:
We present the first on-sky results from an ultra-low-readout-noise Skipper CCD focal plane prototype for the SOAR Integral Field Spectrograph (SIFS). The Skipper CCD focal plane consists of four 6k x 1k, 15 $μ$m pixel, fully-depleted, p-channel devices that have been thinned to ~250 $μ$m, backside processed, and treated with an anti-reflective coating. These Skipper CCDs were configured for astro…
▽ More
We present the first on-sky results from an ultra-low-readout-noise Skipper CCD focal plane prototype for the SOAR Integral Field Spectrograph (SIFS). The Skipper CCD focal plane consists of four 6k x 1k, 15 $μ$m pixel, fully-depleted, p-channel devices that have been thinned to ~250 $μ$m, backside processed, and treated with an anti-reflective coating. These Skipper CCDs were configured for astronomical spectroscopy, i.e., single-sample readout noise < 4.3 e- rms/pixel, the ability to achieve multi-sample readout noise $\ll$ 1 e- rms/pixel, full-well capacities ~40,000-65,000 e-, low dark current and charge transfer inefficiency (~2 x 10$^{-4}$ e-/pixel/s and 3.44 x 10$^{-7}$, respectively), and an absolute quantum efficiency of $\gtrsim$ 80% between 450 nm and 980 nm ($\gtrsim$ 90% between 600 nm and 900 nm). We optimized the readout sequence timing to achieve sub-electron noise (~0.5 e- rms/pixel) in a region of 2k x 4k pixels and photon-counting noise (~0.22 e- rms/pixel) in a region of 220 x 4k pixels, each with a readout time of $\lesssim$ 17 min. We observed two quasars (HB89 1159+123 and QSO J1621-0042) at redshift z ~ 3.5, two high-redshift galaxy clusters (CL J1001+0220 and SPT-CL J2040-4451), an emission line galaxy at z = 0.3239, a candidate member star of the Boötes II ultra-faint dwarf galaxy, and five CALSPEC spectrophotometric standard stars (HD074000, HD60753, HD106252, HD101452, HD200654). We present charge-quantized, photon-counting observations of the quasar HB89 1159+123 and show the detector sensitivity increase for faint spectral features. We demonstrate signal-to-noise performance improvements for SIFS observations in the low-background, readout-noise-dominated regime. We outline scientific studies that will leverage the SIFS-Skipper CCD data and new detector architectures that utilize the Skipper floating gate amplifier with faster readout times.
△ Less
Submitted 15 June, 2024;
originally announced June 2024.
-
Multi-Amplifier Sensing Charge-coupled Devices for Next Generation Spectroscopy
Authors:
Kenneth W. Lin,
Armin Karcher,
Julien Guy,
Stephen E. Holland,
William F. Kolbe,
Peter E. Nugent,
Alex Drlica-Wagner,
Ana M. Botti,
Javier Tiffenberg
Abstract:
We present characterization results and performance of a prototype Multiple-Amplifier Sensing (MAS) silicon charge-coupled device (CCD) sensor with 16 channels potentially suitable for faint object astronomical spectroscopy and low-signal, photon-limited imaging. The MAS CCD is designed to reach sub-electron readout noise by repeatedly measuring charge through a line of amplifiers during the seria…
▽ More
We present characterization results and performance of a prototype Multiple-Amplifier Sensing (MAS) silicon charge-coupled device (CCD) sensor with 16 channels potentially suitable for faint object astronomical spectroscopy and low-signal, photon-limited imaging. The MAS CCD is designed to reach sub-electron readout noise by repeatedly measuring charge through a line of amplifiers during the serial transfer shifts. Using synchronized readout electronics based on the DESI CCD controller, we report a read noise of 1.03 e$^-$ rms/pix at a speed of 26 $μ$s/pix with a single-sample readout scheme where charge in a pixel is measured only once for each output stage. At these operating parameters, we find the amplifier-to-amplifier charge transfer efficiency (ACTE) to be $>0.9995$ at low counts for all amplifiers but one for which the ACTE is 0.997. This charge transfer efficiency falls above 50,000 electrons for the read-noise optimized voltage configuration we chose for the serial clocks and gates. The amplifier linearity across a broad dynamic range from $\sim$300 to 35,000 e$^-$ was also measured to be $\pm 2.5\%$. We describe key operating parameters to optimize on these characteristics and describe the specific applications for which the MAS CCD may be a suitable detector candidate.
△ Less
Submitted 30 August, 2024; v1 submitted 10 June, 2024;
originally announced June 2024.
-
A Sixteen Multiple-Amplifier-Sensing CCD and Characterization Techniques Targeting The Next Generation of Astronomical Instruments
Authors:
Agustin J. Lapi,
Blas J. Irigoyen Gimenez,
Miqueas E. Gamero,
Claudio R. Chavez Blanco,
Fernando Chierchie,
Guillermo Fernandez Moroni,
Stephen E. Holland,
Juan Estrada,
Javier Tiffenberg
Abstract:
This work presents a candidate sensor for future spectroscopic applications, such as a Stage-5 Spectroscopic Survey Experiment or the Habitable Worlds Observatory. This new type of CCD sensor features multiple in-line amplifiers at its output stage allowing multiple measurements of the same charge packet, either in each amplifier and/or in the different amplifiers. Recently, the operation of an 8-…
▽ More
This work presents a candidate sensor for future spectroscopic applications, such as a Stage-5 Spectroscopic Survey Experiment or the Habitable Worlds Observatory. This new type of CCD sensor features multiple in-line amplifiers at its output stage allowing multiple measurements of the same charge packet, either in each amplifier and/or in the different amplifiers. Recently, the operation of an 8-amplifier sensor has been experimentally demonstrated, and the operation of a 16-amplifier sensor is presented in this work. This new sensor enables a noise level of approximately $1^e_{\rm rms}$ with a single sample per amplifier. Additionally, it is shown that sub-electron noise can be achieved using multiple samples per amplifier. In addition to demonstrating the performance of the 16-amplifier sensor, this work aims to create a framework for future analysis and performance optimization of this type of detectors. New models and techniques are presented to characterize specific parameters, which are absent in conventional CCDs and Skipper-CCDs: charge transfer between amplifiers and independent and common noise in the amplifiers, and their processing.
△ Less
Submitted 29 May, 2024;
originally announced May 2024.
-
SENSEI: First Direct-Detection Results on sub-GeV Dark Matter from SENSEI at SNOLAB
Authors:
SENSEI Collaboration,
Prakruth Adari,
Itay M. Bloch,
Ana M. Botti,
Mariano Cababie,
Gustavo Cancelo,
Brenda A. Cervantes-Vergara,
Michael Crisler,
Miguel Daal,
Ansh Desai,
Alex Drlica-Wagner,
Rouven Essig,
Juan Estrada,
Erez Etzion,
Guillermo Fernandez Moroni,
Stephen E. Holland,
Yonatan Kehat,
Yaron Korn,
Ian Lawson,
Steffon Luoma,
Aviv Orly,
Santiago E. Perez,
Dario Rodrigues,
Nathan A. Saffold,
Silvia Scorza
, et al. (12 additional authors not shown)
Abstract:
We present the first results from a dark matter search using six Skipper-CCDs in the SENSEI detector operating at SNOLAB. With an exposure of 534.9 gram-days from well-performing sensors, we select events containing 2 to 10 electron-hole pairs. After aggressively masking images to remove backgrounds, we observe 55 two-electron events, 4 three-electron events, and no events containing 4 to 10 elect…
▽ More
We present the first results from a dark matter search using six Skipper-CCDs in the SENSEI detector operating at SNOLAB. With an exposure of 534.9 gram-days from well-performing sensors, we select events containing 2 to 10 electron-hole pairs. After aggressively masking images to remove backgrounds, we observe 55 two-electron events, 4 three-electron events, and no events containing 4 to 10 electrons. The two-electron events are consistent with pileup from one-electron events. Among the 4 three-electron events, 2 appear in pixels that are likely impacted by detector defects, although not strongly enough to trigger our "hot-pixel" mask. We use these data to set world-leading constraints on sub-GeV dark matter interacting with electrons and nuclei.
△ Less
Submitted 20 December, 2023;
originally announced December 2023.
-
Fast Single-Quantum Measurement with a Multi-Amplifier Sensing Charge-Coupled Device
Authors:
Ana M. Botti,
Brenda A. Cervantes-Vergara,
Claudio R. Chavez,
Fernando Chierchie,
Alex Drlica-Wagner,
Juan Estrada,
Guillermo Fernandez Moroni,
Stephen E. Holland,
Blas J. Irigoyen Gimenez,
Agustin J. Lapi,
Edgar Marrufo Villalpando,
Miguel Sofo Haro,
Javier Tiffenberg,
Sho Uemura
Abstract:
A novel readout architecture that uses multiple non-destructive floating-gate amplifiers to achieve sub-electron readout noise in a thick, fully-depleted silicon detector is presented. This Multi-Amplifier Sensing Charge-Coupled Device (MAS-CCD) can perform multiple independent charge measurements with each amplifier; measurements with multiple amplifiers can then be combined to further reduce the…
▽ More
A novel readout architecture that uses multiple non-destructive floating-gate amplifiers to achieve sub-electron readout noise in a thick, fully-depleted silicon detector is presented. This Multi-Amplifier Sensing Charge-Coupled Device (MAS-CCD) can perform multiple independent charge measurements with each amplifier; measurements with multiple amplifiers can then be combined to further reduce the readout noise. The readout speed of this detector scales roughly linearly with the number of amplifiers without requiring segmentation of the active area. The performance of this detector is demonstrated, emphasizing the ability to resolve individual quanta and the ability to combine measurements across amplifiers to reduce readout noise. The unprecedented low noise and fast readout of the MAS-CCD make it a unique technology for astronomical observations, quantum imaging, and low-energy interacting particles.
△ Less
Submitted 18 August, 2023;
originally announced August 2023.
-
Confirmation of the spectral excess in DAMIC at SNOLAB with skipper CCDs
Authors:
A. Aguilar-Arevalo,
I. Arnquist,
N. Avalos,
L. Barak,
D. Baxter,
X. Bertou,
I. M. Bloch,
A. M. Botti,
M. Cababie,
G. Cancelo,
N. Castelló-Mor,
B. A. Cervantes-Vergara,
A. E. Chavarria,
J. Cortabitarte-Gutiérrez,
M. Crisler,
J. Cuevas-Zepeda,
A. Dastgheibi-Fard,
C. De Dominicis,
O. Deligny,
A. Drlica-Wagner,
J. Duarte-Campderros,
J. C. D'Olivo,
R. Essig,
E. Estrada,
J. Estrada
, et al. (47 additional authors not shown)
Abstract:
We present results from a 3.25 kg-day target exposure of two silicon charge-coupled devices (CCDs), each with 24 megapixels and skipper readout, deployed in the DAMIC setup at SNOLAB. With a reduction in pixel readout noise of a factor of 10 relative to the previous detector, we investigate the excess population of low-energy events in the CCD bulk previously observed above expected backgrounds. W…
▽ More
We present results from a 3.25 kg-day target exposure of two silicon charge-coupled devices (CCDs), each with 24 megapixels and skipper readout, deployed in the DAMIC setup at SNOLAB. With a reduction in pixel readout noise of a factor of 10 relative to the previous detector, we investigate the excess population of low-energy events in the CCD bulk previously observed above expected backgrounds. We address the dominant systematic uncertainty of the previous analysis through a depth fiducialization designed to reject surface backgrounds on the CCDs. The measured bulk ionization spectrum confirms the presence of an excess population of low-energy events in the CCD target with characteristic rate of ${\sim}7$ events per kg-day and electron-equivalent energies of ${\sim}80~$eV, whose origin remains unknown.
△ Less
Submitted 26 March, 2024; v1 submitted 2 June, 2023;
originally announced June 2023.
-
SENSEI: Search for Millicharged Particles produced in the NuMI Beam
Authors:
Liron Barak,
Itay M. Bloch,
Ana M. Botti,
Mariano Cababie,
Gustavo Cancelo,
Luke Chaplinsky,
Michael Crisler,
Alex Drlica-Wagner,
Rouven Essig,
Juan Estrada,
Erez Etzion,
Guillermo Fernandez Moroni,
Roni Harnik,
Stephen E. Holland,
Yaron Korn,
Zhen Liu,
Sravan Munagavalasa,
Aviv Orly,
Santiago E. Perez,
Ryan Plestid,
Dario Rodrigues,
Nathan A. Saffold,
Silvia Scorza,
Aman Singal,
Miguel Sofo Haro
, et al. (6 additional authors not shown)
Abstract:
Millicharged particles appear in several extensions of the Standard Model, but have not yet been detected. These hypothetical particles could be produced by an intense proton beam striking a fixed target. We use data collected in 2020 by the SENSEI experiment in the MINOS cavern at the Fermi National Accelerator Laboratory to search for ultra-relativistic millicharged particles produced in collisi…
▽ More
Millicharged particles appear in several extensions of the Standard Model, but have not yet been detected. These hypothetical particles could be produced by an intense proton beam striking a fixed target. We use data collected in 2020 by the SENSEI experiment in the MINOS cavern at the Fermi National Accelerator Laboratory to search for ultra-relativistic millicharged particles produced in collisions of protons in the NuMI beam with a fixed graphite target. The absence of any ionization events with 3 to 6 electrons in the SENSEI data allow us to place world-leading constraints on millicharged particles for masses between 30 MeV to 380 MeV. This work also demonstrates the potential of utilizing low-threshold detectors to investigate new particles in beam-dump experiments, and motivates a future experiment designed specifically for this purpose.
△ Less
Submitted 24 May, 2023; v1 submitted 8 May, 2023;
originally announced May 2023.
-
Solid State Detectors and Tracking for Snowmass
Authors:
A. Affolder,
A. Apresyan,
S. Worm,
M. Albrow,
D. Ally,
D. Ambrose,
E. Anderssen,
N. Apadula,
P. Asenov,
W. Armstrong,
M. Artuso,
A. Barbier,
P. Barletta,
L. Bauerdick,
D. Berry,
M. Bomben,
M. Boscardin,
J. Brau,
W. Brooks,
M. Breidenbach,
J. Buckley,
V. Cairo,
R. Caputo,
L. Carpenter,
M. Centis-Vignali
, et al. (110 additional authors not shown)
Abstract:
Tracking detectors are of vital importance for collider-based high energy physics (HEP) experiments. The primary purpose of tracking detectors is the precise reconstruction of charged particle trajectories and the reconstruction of secondary vertices. The performance requirements from the community posed by the future collider experiments require an evolution of tracking systems, necessitating the…
▽ More
Tracking detectors are of vital importance for collider-based high energy physics (HEP) experiments. The primary purpose of tracking detectors is the precise reconstruction of charged particle trajectories and the reconstruction of secondary vertices. The performance requirements from the community posed by the future collider experiments require an evolution of tracking systems, necessitating the development of new techniques, materials and technologies in order to fully exploit their physics potential. In this article we summarize the discussions and conclusions of the 2022 Snowmass Instrumentation Frontier subgroup on Solid State and Tracking Detectors (Snowmass IF03).
△ Less
Submitted 19 October, 2022; v1 submitted 8 September, 2022;
originally announced September 2022.
-
Fast Timing With Silicon Carbide Low Gain Avalanche Detectors
Authors:
P. Barletta,
M. Cerullo,
C. Haber,
S. E. Holland,
J. Muth,
B. Sekely
Abstract:
4H-Silicon Carbide, when considered as a material for the fabrication of Low Gain Avalanche Detectors for particle timing and position measurement, offers potential advantages over Silicon. We discuss an ongoing study of this material aimed at the fabrication and test of prototype fast timing sensors. This work is well aligned with technical directions identified in the recent Department of Energy…
▽ More
4H-Silicon Carbide, when considered as a material for the fabrication of Low Gain Avalanche Detectors for particle timing and position measurement, offers potential advantages over Silicon. We discuss an ongoing study of this material aimed at the fabrication and test of prototype fast timing sensors. This work is well aligned with technical directions identified in the recent Department of Energy study, Basic Research Needs for High Energy Physics Detector Research and Development.
△ Less
Submitted 16 March, 2022;
originally announced March 2022.
-
EXCESS workshop: Descriptions of rising low-energy spectra
Authors:
P. Adari,
A. Aguilar-Arevalo,
D. Amidei,
G. Angloher,
E. Armengaud,
C. Augier,
L. Balogh,
S. Banik,
D. Baxter,
C. Beaufort,
G. Beaulieu,
V. Belov,
Y. Ben Gal,
G. Benato,
A. Benoît,
A. Bento,
L. Bergé,
A. Bertolini,
R. Bhattacharyya,
J. Billard,
I. M. Bloch,
A. Botti,
R. Breier,
G. Bres,
J-. L. Bret
, et al. (281 additional authors not shown)
Abstract:
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was…
▽ More
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was initiated. In its first iteration in June 2021, ten rare event search collaborations contributed to this initiative via talks and discussions. The contributing collaborations were CONNIE, CRESST, DAMIC, EDELWEISS, MINER, NEWS-G, NUCLEUS, RICOCHET, SENSEI and SuperCDMS. They presented data about their observed energy spectra and known backgrounds together with details about the respective measurements. In this paper, we summarize the presented information and give a comprehensive overview of the similarities and differences between the distinct measurements. The provided data is furthermore publicly available on the workshop's data repository together with a plotting tool for visualization.
△ Less
Submitted 4 March, 2022; v1 submitted 10 February, 2022;
originally announced February 2022.
-
The Skipper CCD for low-energy threshold particle experiments above ground
Authors:
Guillermo Fernandez Moroni,
Fernando Chierchie,
Javier Tiffenberg,
Ana Botti,
Mariano Cababie,
Gustavo Cancelo,
Eliana L. Depaoli,
Juan Estrada,
Stephen E. Holland,
Dario Rodrigues,
Iván Sidelnik,
Miguel Sofo Haro,
Leandro Stefanazzi,
Sho Uemura
Abstract:
We present experimental results using a single-electron resolution Skipper-CCD running above ground level to demonstrate the potential of this technology for its use in reactor neutrino observations and other low-energy particle interaction experiments. Operating conditions and event-selection criteria are provided to decouple most of the background rate at low energies. Our final results for even…
▽ More
We present experimental results using a single-electron resolution Skipper-CCD running above ground level to demonstrate the potential of this technology for its use in reactor neutrino observations and other low-energy particle interaction experiments. Operating conditions and event-selection criteria are provided to decouple most of the background rate at low energies. Our final results for events with energies as low as $5$ ionized electron-hole pairs show that the exponentially increasing rate of events seen in other technologies is not present in our data. This demonstrates that the Skipper CCD proves to be among the best options to measure low energy and weakly interacting particles at ground level.
△ Less
Submitted 30 August, 2021; v1 submitted 30 June, 2021;
originally announced July 2021.
-
SENSEI: Characterization of Single-Electron Events Using a Skipper-CCD
Authors:
Liron Barak,
Itay M. Bloch,
Ana Botti,
Mariano Cababie,
Gustavo Cancelo,
Luke Chaplinsky,
Fernando Chierchie,
Michael Crisler,
Alex Drlica-Wagner,
Rouven Essig,
Juan Estrada,
Erez Etzion,
Guillermo Fernandez Moroni,
Daniel Gift,
Stephen E. Holland,
Sravan Munagavalasa,
Aviv Orly,
Dario Rodrigues,
Aman Singal,
Miguel Sofo Haro,
Leandro Stefanazzi,
Javier Tiffenberg,
Sho Uemura,
Tomer Volansky,
Tien-Tien Yu
Abstract:
We use a science-grade Skipper Charge Coupled Device (Skipper-CCD) operating in a low-radiation background environment to develop a semi-empirical model that characterizes the origin of single-electron events in CCDs. We identify, separate, and quantify three independent contributions to the single-electron events, which were previously bundled together and classified as "dark counts": dark curren…
▽ More
We use a science-grade Skipper Charge Coupled Device (Skipper-CCD) operating in a low-radiation background environment to develop a semi-empirical model that characterizes the origin of single-electron events in CCDs. We identify, separate, and quantify three independent contributions to the single-electron events, which were previously bundled together and classified as "dark counts": dark current, amplifier light, and spurious charge. We measure a dark current, which depends on exposure, of (5.89+-0.77)x10^-4 e-/pix/day, and an unprecedentedly low spurious charge contribution of (1.52+-0.07)x10^-4 e-/pix, which is exposure-independent. In addition, we provide a technique to study events produced by light emitted from the amplifier, which allows the detector's operation to be optimized to minimize this effect to a level below the dark-current contribution. Our accurate characterization of the single-electron events allows one to greatly extend the sensitivity of experiments searching for dark matter or coherent neutrino scattering. Moreover, an accurate understanding of the origin of single-electron events is critical to further progress in ongoing R&D efforts of Skipper and conventional CCDs.
△ Less
Submitted 26 January, 2022; v1 submitted 15 June, 2021;
originally announced June 2021.
-
Quantum efficiency modeling for a thick back-illuminated astronomical CCD
Authors:
D. E. Groom,
S. Haque,
S. E. Holland,
W. F. Kolbe
Abstract:
The quantum efficiency and reflectivity of thick, back-illuminated CCD's being fabricated at LBNL for astronomical applications are modeled and compared with experiment. The treatment differs from standard thin-film optics in that (a) absorption is permitted in any film, (b) the 200--500~$μ$m thick silicon substrate is considered as a thin film in order to observe the fringing behavior at long wav…
▽ More
The quantum efficiency and reflectivity of thick, back-illuminated CCD's being fabricated at LBNL for astronomical applications are modeled and compared with experiment. The treatment differs from standard thin-film optics in that (a) absorption is permitted in any film, (b) the 200--500~$μ$m thick silicon substrate is considered as a thin film in order to observe the fringing behavior at long wavelengths, and (c) by using approximate boundary conditions, absorption in the surface films is separated from absorption in the substrate. For the quantum efficiency measurements the CCD's are normally operated as CCD's, usually at $T = -140^\circ$C, and at higher temperatures as photodiodes. They are mounted on mechanical substrates. Reflectivity is measured on air-backed wafer samples at room temperature. The agreement between model expectation and quantum efficiency measurement is in general satisfactory.
△ Less
Submitted 9 August, 2017;
originally announced August 2017.
-
The Dark Energy Camera
Authors:
B. Flaugher,
H. T. Diehl,
K. Honscheid,
T. M. C. Abbott,
O. Alvarez,
R. Angstadt,
J. T. Annis,
M. Antonik,
O. Ballester,
L. Beaufore,
G. M. Bernstein,
R. A. Bernstein,
B. Bigelow,
M. Bonati,
D. Boprie,
D. Brooks,
E. J. Buckley-Geer,
J. Campa,
L. Cardiel-Sas,
F. J. Castander,
J. Castilla,
H. Cease,
J. M. Cela-Ruiz,
S. Chappa,
E. Chi
, et al. (93 additional authors not shown)
Abstract:
The Dark Energy Camera is a new imager with a 2.2-degree diameter field of view mounted at the prime focus of the Victor M. Blanco 4-meter telescope on Cerro Tololo near La Serena, Chile. The camera was designed and constructed by the Dark Energy Survey Collaboration, and meets or exceeds the stringent requirements designed for the wide-field and supernova surveys for which the collaboration uses…
▽ More
The Dark Energy Camera is a new imager with a 2.2-degree diameter field of view mounted at the prime focus of the Victor M. Blanco 4-meter telescope on Cerro Tololo near La Serena, Chile. The camera was designed and constructed by the Dark Energy Survey Collaboration, and meets or exceeds the stringent requirements designed for the wide-field and supernova surveys for which the collaboration uses it. The camera consists of a five element optical corrector, seven filters, a shutter with a 60 cm aperture, and a CCD focal plane of 250 micron thick fully-depleted CCDs cooled inside a vacuum Dewar. The 570 Mpixel focal plane comprises 62 2kx4k CCDs for imaging and 12 2kx2k CCDs for guiding and focus. The CCDs have 15 microns x15 microns pixels with a plate scale of 0.263 arc sec per pixel. A hexapod system provides state-of-the-art focus and alignment capability. The camera is read out in 20 seconds with 6-9 electrons readout noise. This paper provides a technical description of the camera's engineering, construction, installation, and current status.
△ Less
Submitted 11 April, 2015;
originally announced April 2015.
-
Physics of Fully Depleted CCDs
Authors:
S. E. Holland,
C. J. Bebek,
W. F. Kolbe,
J. S. Lee
Abstract:
In this work we present simple, physics-based models for two effects that have been noted in the fully depleted CCDs that are presently used in the Dark Energy Survey Camera. The first effect is the observation that the point-spread function increases slightly with the signal level. This is explained by considering the effect on charge-carrier diffusion due to the reduction in the magnitude of the…
▽ More
In this work we present simple, physics-based models for two effects that have been noted in the fully depleted CCDs that are presently used in the Dark Energy Survey Camera. The first effect is the observation that the point-spread function increases slightly with the signal level. This is explained by considering the effect on charge-carrier diffusion due to the reduction in the magnitude of the channel potential as collected signal charge acts to partially neutralize the fixed charge in the depleted channel. The resulting reduced voltage drop across the carrier drift region decreases the vertical electric field and increases the carrier transit time. The second effect is the observation of low-level, concentric ring patterns seen in uniformly illuminated images. This effect is shown to be most likely due to lateral deflection of charge during the transit of the photogenerated carriers to the potential wells as a result of lateral electric fields. The lateral fields are a result of space charge in the fully depleted substrates arising from resistivity variations inherent to the growth of the high-resistivity silicon used to fabricate the CCDs.
△ Less
Submitted 24 March, 2014;
originally announced March 2014.
-
Achieving sub-electron readout noise in Skipper CCDs
Authors:
Guillermo Fernandez Moroni,
Juan Estrada,
Eduardo E. Paolini,
Gustavo Cancelo,
Stephen E. Holland,
H. Thomas Diehl
Abstract:
The readout noise for Charge-Coupled Devices (CCDs) has been the main limitation when using these detectors for measuring small amplitude signals. A readout system for a new scientific, low noise CCD is presented in this paper. The Skipper CCD architecture, and its advantages for low noise applications are discussed. A technique for obtaining sub-electron readout noise levels is presented, and its…
▽ More
The readout noise for Charge-Coupled Devices (CCDs) has been the main limitation when using these detectors for measuring small amplitude signals. A readout system for a new scientific, low noise CCD is presented in this paper. The Skipper CCD architecture, and its advantages for low noise applications are discussed. A technique for obtaining sub-electron readout noise levels is presented, and its noise and signal characteristics are derived. We demonstrate a very low readout noise of $0.2e^{-}$ RMS. Also, we show the results using the detector in a low-energy X-ray detection experiment.
△ Less
Submitted 14 June, 2011; v1 submitted 9 June, 2011;
originally announced June 2011.