Spark probability measurement of a single mask triple GEM detector
Authors:
S. Chatterjee,
U. Frankenfeld,
C. Garabatos,
J. Hehner,
T. Morhardt,
C. J. Schmidt,
H. R. Schmidt,
C. A. Lymanets,
S. Biswas
Abstract:
Triple Gas Electron Multiplier (GEM) detectors will be used as a tracking device in the first two stations of CBM MUon CHamber (MUCH), where the maximum particle rate is expected to reach ~1 MHz/cm2 for central Au-Au collisions at 8 AGeV. Therefore, the stable operation of the detector is very important. Discharge probability has been measured of a single mask triple GEM detector at the CERN SPS/H…
▽ More
Triple Gas Electron Multiplier (GEM) detectors will be used as a tracking device in the first two stations of CBM MUon CHamber (MUCH), where the maximum particle rate is expected to reach ~1 MHz/cm2 for central Au-Au collisions at 8 AGeV. Therefore, the stable operation of the detector is very important. Discharge probability has been measured of a single mask triple GEM detector at the CERN SPS/H4 beam-line facility with a pion beam of ~150 GeV/c and also in an environment of highly ionizing shower particles. The spark probability as a function of gain has been studied for different particle rates. The details of the experimental setup, method of spark identification and results are presented in this paper.
△ Less
Submitted 2 July, 2021;
originally announced July 2021.
-
The upgrade of the ALICE TPC with GEMs and continuous readout
Authors:
J. Adolfsson,
M. Ahmed,
S. Aiola,
J. Alme,
T. Alt,
W. Amend,
F. Anastasopoulos,
C. Andrei,
M. Angelsmark,
V. Anguelov,
A. Anjam,
H. Appelshäuser,
V. Aprodu,
O. Arnold,
M. Arslandok,
D. Baitinger,
M. Ball,
G. G. Barnaföldi,
E. Bartsch,
P. Becht,
R. Bellwied,
A. Berdnikova,
M. Berger,
N. Bialas,
P. Bialas
, et al. (210 additional authors not shown)
Abstract:
The upgrade of the ALICE TPC will allow the experiment to cope with the high interaction rates foreseen for the forthcoming Run 3 and Run 4 at the CERN LHC. In this article, we describe the design of new readout chambers and front-end electronics, which are driven by the goals of the experiment. Gas Electron Multiplier (GEM) detectors arranged in stacks containing four GEMs each, and continuous re…
▽ More
The upgrade of the ALICE TPC will allow the experiment to cope with the high interaction rates foreseen for the forthcoming Run 3 and Run 4 at the CERN LHC. In this article, we describe the design of new readout chambers and front-end electronics, which are driven by the goals of the experiment. Gas Electron Multiplier (GEM) detectors arranged in stacks containing four GEMs each, and continuous readout electronics based on the SAMPA chip, an ALICE development, are replacing the previous elements. The construction of these new elements, together with their associated quality control procedures, is explained in detail. Finally, the readout chamber and front-end electronics cards replacement, together with the commissioning of the detector prior to installation in the experimental cavern, are presented. After a nine-year period of R&D, construction, and assembly, the upgrade of the TPC was completed in 2020.
△ Less
Submitted 25 March, 2021; v1 submitted 17 December, 2020;
originally announced December 2020.
-
Particle identification studies with a full-size 4-GEM prototype for the ALICE TPC upgrade
Authors:
M. M. Aggarwal,
Z. Ahammed,
S. Aiola,
J. Alme,
T. Alt,
W. Amend,
A. Andronic,
V. Anguelov,
H. Appelshäuser,
M. Arslandok,
R. Averbeck,
M. Ball,
G. G. Barnaföldi,
E. Bartsch,
R. Bellwied,
G. Bencedi,
M. Berger,
N. Bialas,
P. Bialas,
L. Bianchi,
S. Biswas,
L. Boldizsár,
L. Bratrud,
P. Braun-Munzinger,
M. Bregant
, et al. (155 additional authors not shown)
Abstract:
A large Time Projection Chamber is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019/20, the LHC will deliver Pb beams colliding at an interaction rate of about 50 kHz, which is about a factor of 50 above the present readout rate of the TPC. This will result in a significant improvement on the sensitivit…
▽ More
A large Time Projection Chamber is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019/20, the LHC will deliver Pb beams colliding at an interaction rate of about 50 kHz, which is about a factor of 50 above the present readout rate of the TPC. This will result in a significant improvement on the sensitivity to rare probes that are considered key observables to characterize the QCD matter created in such collisions. In order to make full use of this luminosity, the currently used gated Multi-Wire Proportional Chambers will be replaced. The upgrade relies on continuously operated readout detectors employing Gas Electron Multiplier technology to retain the performance in terms of particle identification via the measurement of the specific energy loss by ionization d$E$/d$x$. A full-size readout chamber prototype was assembled in 2014 featuring a stack of four GEM foils as an amplification stage. The performance of the prototype was evaluated in a test beam campaign at the CERN PS. The d$E$/d$x$ resolution complies with both the performance of the currently operated MWPC-based readout chambers and the challenging requirements of the ALICE TPC upgrade program. Detailed simulations of the readout system are able to reproduce the data.
△ Less
Submitted 17 June, 2018; v1 submitted 8 May, 2018;
originally announced May 2018.
-
A Large Ungated TPC with GEM Amplification
Authors:
M. Berger,
M. Ball,
L. Fabbietti,
B. Ketzer,
R. Arora,
R. Beck,
F. Böhmer,
J. -C. Chen,
F. Cusanno,
S. Dørheim,
J. Hehner,
N. Herrmann,
C. Höppner,
D. Kaiser,
M. Kis,
V. Kleipa,
I. Konorov,
J. Kunkel,
N. Kurz,
Y. Leifels,
P. Müllner,
R. Münzer,
S. Neubert,
J. Rauch,
C. J. Schmidt
, et al. (6 additional authors not shown)
Abstract:
A Time Projection Chamber (TPC) is an ideal device for the detection of charged particle tracks in a large volume covering a solid angle of almost $4π$. The high density of hits on a given particle track facilitates the task of pattern recognition in a high-occupancy environment and in addition provides particle identification by measuring the specific energy loss for each track. For these reasons…
▽ More
A Time Projection Chamber (TPC) is an ideal device for the detection of charged particle tracks in a large volume covering a solid angle of almost $4π$. The high density of hits on a given particle track facilitates the task of pattern recognition in a high-occupancy environment and in addition provides particle identification by measuring the specific energy loss for each track. For these reasons, TPCs with Multiwire Proportional Chamber (MWPC) amplification have been and are widely used in experiments recording heavy-ion collisions. A significant drawback, however, is the large dead time of the order of 1 ms per event generated by the use of a gating grid, which is mandatory to prevent ions created in the amplification region from drifting back into the drift volume, where they would severely distort the drift path of subsequent tracks. For experiments with higher event rates this concept of a conventional TPC operating with a triggered gating grid can therefore not be applied without a significant loss of data. A continuous readout of the signals is the more appropriate way of operation. This, however, constitutes a change of paradigm with considerable challenges to be met concerning the amplification region, the design and bandwidth of the readout electronics, and the data handling. A mandatory prerequisite for such an operation is a sufficiently good suppression of the ion backflow from the avalanche region, which otherwise limits the tracking and particle identification capabilities of such a detector. Gas Electron Multipliers (GEM) are a promising candidate to combine excellent spatial resolution with an intrinsic suppression of ions. In this paper we describe the design, construction and the commissioning of a large TPC with GEM amplification and without gating grid (GEM-TPC).
△ Less
Submitted 16 February, 2017;
originally announced February 2017.
-
Challenges in QCD matter physics - The Compressed Baryonic Matter experiment at FAIR
Authors:
CBM Collaboration,
T. Ablyazimov,
A. Abuhoza,
R. P. Adak,
M. Adamczyk,
K. Agarwal,
M. M. Aggarwal,
Z. Ahammed,
F. Ahmad,
N. Ahmad,
S. Ahmad,
A. Akindinov,
P. Akishin,
E. Akishina,
T. Akishina,
V. Akishina,
A. Akram,
M. Al-Turany,
I. Alekseev,
E. Alexandrov,
I. Alexandrov,
S. Amar-Youcef,
M. Anđelić,
O. Andreeva,
C. Andrei
, et al. (563 additional authors not shown)
Abstract:
Substantial experimental and theoretical efforts worldwide are devoted to explore the phase diagram of strongly interacting matter. At LHC and top RHIC energies, QCD matter is studied at very high temperatures and nearly vanishing net-baryon densities. There is evidence that a Quark-Gluon-Plasma (QGP) was created at experiments at RHIC and LHC. The transition from the QGP back to the hadron gas is…
▽ More
Substantial experimental and theoretical efforts worldwide are devoted to explore the phase diagram of strongly interacting matter. At LHC and top RHIC energies, QCD matter is studied at very high temperatures and nearly vanishing net-baryon densities. There is evidence that a Quark-Gluon-Plasma (QGP) was created at experiments at RHIC and LHC. The transition from the QGP back to the hadron gas is found to be a smooth cross over. For larger net-baryon densities and lower temperatures, it is expected that the QCD phase diagram exhibits a rich structure, such as a first-order phase transition between hadronic and partonic matter which terminates in a critical point, or exotic phases like quarkyonic matter. The discovery of these landmarks would be a breakthrough in our understanding of the strong interaction and is therefore in the focus of various high-energy heavy-ion research programs. The Compressed Baryonic Matter (CBM) experiment at FAIR will play a unique role in the exploration of the QCD phase diagram in the region of high net-baryon densities, because it is designed to run at unprecedented interaction rates. High-rate operation is the key prerequisite for high-precision measurements of multi-differential observables and of rare diagnostic probes which are sensitive to the dense phase of the nuclear fireball. The goal of the CBM experiment at SIS100 (sqrt(s_NN) = 2.7 - 4.9 GeV) is to discover fundamental properties of QCD matter: the phase structure at large baryon-chemical potentials (mu_B > 500 MeV), effects of chiral symmetry, and the equation-of-state at high density as it is expected to occur in the core of neutron stars. In this article, we review the motivation for and the physics programme of CBM, including activities before the start of data taking in 2022, in the context of the worldwide efforts to explore high-density QCD matter.
△ Less
Submitted 29 March, 2017; v1 submitted 6 July, 2016;
originally announced July 2016.
-
Systematic measurements of the gain and the energy resolution of single and double mask GEM detectors
Authors:
S. Biswas,
D. J. Schmidt,
A. Abuhoza,
U. Frankenfeld,
C. Garabatos,
J. Hehner,
V. Kleipa,
T. Morhardt,
C. J. Schmidt,
H. R. Schmidt,
J. Wiechula
Abstract:
Systematic studies on the gain and the energy resolution have been carried out varying the voltage across the GEM foils for both single mask and double mask triple GEM detector prototypes. Variation of the gain and the energy resolution have also been measured varying either the drift voltage, transfer voltage and induction voltage keeping other voltages constant. The results of the systematic mea…
▽ More
Systematic studies on the gain and the energy resolution have been carried out varying the voltage across the GEM foils for both single mask and double mask triple GEM detector prototypes. Variation of the gain and the energy resolution have also been measured varying either the drift voltage, transfer voltage and induction voltage keeping other voltages constant. The results of the systematic measurements has been presented.
△ Less
Submitted 26 May, 2015;
originally announced May 2015.
-
Measurement of spark probability of GEM detector for CBM muon chamber (MUCH)
Authors:
S. Biswas,
A. Abuhoza,
U. Frankenfeld,
C. Garabatos,
J. Hehner,
V. Kleipa,
T. Morhardt,
C. J. Schmidt,
H. R. Schmidt,
J. Wiechula
Abstract:
The stability of triple GEM detector setups in an environment of high energetic showers is studied. To this end the spark probability in a shower environment is compared to the spark probability in a pion beam.
The stability of triple GEM detector setups in an environment of high energetic showers is studied. To this end the spark probability in a shower environment is compared to the spark probability in a pion beam.
△ Less
Submitted 31 March, 2015;
originally announced April 2015.
-
Study of the characteristics of GEM detectors for the future FAIR experiment CBM
Authors:
S. Biswas,
A. Abuhoza,
U. Frankenfeld,
J. Hehner,
C. J. Schmidt,
H. R. Schmidt,
M. Traeger,
S. Colafranceschi,
A. Marinov,
A. Sharma
Abstract:
Characteristics of triple GEM detector have been studied systematically. The variation of the effective gain and energy resolution of GEM with variation of the applied voltage has been measured with Fe55 X-ray source for different gas mixtures and with different gas flow rates. Long-term test of the GEM has also been performed.
Characteristics of triple GEM detector have been studied systematically. The variation of the effective gain and energy resolution of GEM with variation of the applied voltage has been measured with Fe55 X-ray source for different gas mixtures and with different gas flow rates. Long-term test of the GEM has also been performed.
△ Less
Submitted 1 August, 2014;
originally announced August 2014.
-
Efficiency determination of resistive plate chambers for fast quasi-monoenergetic neutrons
Authors:
M. Röder,
Z. Elekes,
T. Aumann,
D. Bemmerer,
K. Boretzky,
C. Caesar,
T. E. Cowan,
J. Hehner,
M. Heil,
M. Kempe,
V. Maroussov,
O. Nusair,
A. V. Prokofiev,
R. Reifarth,
M. Sobiella,
D. Stach,
A. Wagner,
D. Yakorev,
A. Zilges,
K. Zuber
Abstract:
Composite detectors made of stainless steel converters and multigap resistive plate chambers have been irradiated with quasi-monoenergetic neutrons with a peak energy of 175MeV. The neutron detection efficiency has been determined using two different methods. The data are in agreement with the output of Monte Carlo simulations. The simulations are then extended to study the response of a hypotheti…
▽ More
Composite detectors made of stainless steel converters and multigap resistive plate chambers have been irradiated with quasi-monoenergetic neutrons with a peak energy of 175MeV. The neutron detection efficiency has been determined using two different methods. The data are in agreement with the output of Monte Carlo simulations. The simulations are then extended to study the response of a hypothetical array made of these detectors to energetic neutrons from a radioactive ion beam experiment.
△ Less
Submitted 10 July, 2014; v1 submitted 23 June, 2014;
originally announced June 2014.
-
Development of a GEM based detector for the CBM Muon Chamber (MUCH)
Authors:
S. Biswas,
D. J. Schmidt,
A. Abuhoza,
U. Frankenfeld,
C. Garabatos,
J. Hehner,
V. Kleipa,
T. Morhardt,
C. J. Schmidt,
H. R. Schmidt,
J. Wiechula
Abstract:
The characteristics of triple GEM detectors have been studied systematically by using cosmic ray muons. The minimum ionizing particle (MIP) spectra has been taken for different GEM voltage setting. Efficiency of GEM detector has been measured for cosmic ray. At high rate operation of GEMs the value of the protection resistor influences the gain and the stability. This feature has been investigated…
▽ More
The characteristics of triple GEM detectors have been studied systematically by using cosmic ray muons. The minimum ionizing particle (MIP) spectra has been taken for different GEM voltage setting. Efficiency of GEM detector has been measured for cosmic ray. At high rate operation of GEMs the value of the protection resistor influences the gain and the stability. This feature has been investigated varying both the rate and the value of the protection resistor. This measurement has been performed using both X-ray generator and Fe55 source. The ageing and long-term stability of GEM based detectors has been studied employing both X-ray generator and Fe55 source. The ageing study of one GEM module is performed by using a 8 keV Cu X-ray generator to verify the stability and integrity of the GEM detectors over a longer period of time. The accumulated charge on the detector is calculated from the rate of the X-ray and the average gain of the detector. The details of the measurement and results has been described in this article.
△ Less
Submitted 3 October, 2013; v1 submitted 2 October, 2013;
originally announced October 2013.
-
Technical Design Study for the PANDA Time Projection Chamber
Authors:
M. Ball,
F. V. Böhmer,
S. Dørheim,
C. Höppner,
B. Ketzer,
I. Konorov,
S. Neubert,
S. Paul,
J. Rauch,
S. Uhl,
M. Vandenbroucke,
M. Berger,
J. -C. Berger-Chen,
F. Cusanno,
L. Fabbietti,
R. Münzer,
R. Arora,
J. Frühauf,
M. Kiš,
Y. Leifels,
V. Kleipa,
J. Hehner,
J. Kunkel,
N. Kurz,
K. Peters
, et al. (16 additional authors not shown)
Abstract:
This document illustrates the technical layout and the expected performance of a Time Projection Chamber as the central tracking system of the PANDA experiment. The detector is based on a continuously operating TPC with Gas Electron Multiplier (GEM) amplification.
This document illustrates the technical layout and the expected performance of a Time Projection Chamber as the central tracking system of the PANDA experiment. The detector is based on a continuously operating TPC with Gas Electron Multiplier (GEM) amplification.
△ Less
Submitted 29 June, 2012;
originally announced July 2012.
-
The PANDA GEM-based TPC Prototype
Authors:
L. Fabbietti,
H. Angerer,
R. Beck,
M. Berger,
F. Böhmer,
K. T. Brinkmann,
P. Bühler,
M. Danner,
S. Dørheim,
C. Funke,
F. Cusanno,
J. Hehner,
A. Heinz,
M. Henske,
C. Höppner,
D. Kaiser,
B. Ketzer,
I. Konorov,
J. Kunkel,
M. Lang,
J. Marton,
S. Neubert,
S. Paul,
A. Schmah,
C. Schmidt
, et al. (15 additional authors not shown)
Abstract:
We report on the development of a GEM-based TPC prototype for the PANDA experiment. The design and requirements of this device will be illustrated, with particular emphasis on the properties of the recently tested GEM-detector, the characterization of the read-out electronics and the development of the tracking software that allows to evaluate the GEM-TPC data.
We report on the development of a GEM-based TPC prototype for the PANDA experiment. The design and requirements of this device will be illustrated, with particular emphasis on the properties of the recently tested GEM-detector, the characterization of the read-out electronics and the development of the tracking software that allows to evaluate the GEM-TPC data.
△ Less
Submitted 26 May, 2010; v1 submitted 23 April, 2010;
originally announced April 2010.
-
Development of a GEM-TPC prototype
Authors:
Heinz Angerer,
Reinhard Beck,
Martin Berger,
Felix Boehmer,
K. -T. Brinkmann,
Paul Buehler,
Michael Carnegie,
Sverre Dorheim,
Laura Fabbietti,
Chr. Funke,
F. Cusanno,
Joerg Hehner,
Andreas Heinz,
Markus Henske,
Christian Hoeppner,
David Kaiser,
Bernhard Ketzer,
Igor Konorov,
Jochen Kunkel,
Michael Lang,
Johann Marton,
Sebastian Neubert,
Stephan Paul,
Alexander Schmah,
Christian Schmidt
, et al. (15 additional authors not shown)
Abstract:
The use of GEM foils for the amplification stage of a TPC instead of a con- ventional MWPC allows one to bypass the necessity of gating, as the backdrift is suppressed thanks to the asymmetric field configuration. This way, a novel continuously running TPC, which represents one option for the PANDA central tracker, can be realized. A medium sized prototype with a diameter of 300 mm and a length…
▽ More
The use of GEM foils for the amplification stage of a TPC instead of a con- ventional MWPC allows one to bypass the necessity of gating, as the backdrift is suppressed thanks to the asymmetric field configuration. This way, a novel continuously running TPC, which represents one option for the PANDA central tracker, can be realized. A medium sized prototype with a diameter of 300 mm and a length of 600 mm will be tested inside the FOPI spectrometer at GSI using a carbon or lithium beam at intermediate energies (E = 1-3AGeV). This detector test under realistic experimental conditions should allow us to verify the spatial resolution for single tracks and the reconstruction capability for displaced vertexes. A series of physics measurement implying pion beams is scheduled with the FOPI spectrometer together with the GEM-TPC as well.
△ Less
Submitted 4 November, 2009;
originally announced November 2009.