Improved Physics-Informed Neural Network based AC Power Flow for Distribution Networks
Authors:
Victor Eeckhout,
Hossein Fani,
Md Umar Hashmi,
Geert Deconinck
Abstract:
Power flow analysis plays a critical role in the control and operation of power systems. The high computational burden of traditional solution methods led to a shift towards data-driven approaches, exploiting the availability of digital metering data. However, data-driven approaches, such as deep learning, have not yet won the trust of operators as they are agnostic to the underlying physical mode…
▽ More
Power flow analysis plays a critical role in the control and operation of power systems. The high computational burden of traditional solution methods led to a shift towards data-driven approaches, exploiting the availability of digital metering data. However, data-driven approaches, such as deep learning, have not yet won the trust of operators as they are agnostic to the underlying physical model and have poor performances in regimes with limited observability. To address these challenges, this paper proposes a new, physics-informed model. More specifically, a novel physics-informed loss function is developed that can be used to train (deep) neural networks aimed at power flow simulation. The loss function is not only based on the theoretical AC power flow equations that govern the problem but also incorporates real physical line losses, resulting in higher loss accuracy and increased learning potential. The proposed model is used to train a Graph Neural Network (GNN) and is evaluated on a small 3-bus test case both against another physics-informed GNN that does not incorporate physical losses and against a model-free technique. The validation results show that the proposed model outperforms the conventional physics-informed network on all used performance metrics. Even more interesting is that the model shows strong prediction capabilities when tested on scenarios outside the training sample set, something that is a substantial deficiency of model-free techniques.
△ Less
Submitted 14 September, 2024;
originally announced September 2024.
-
Distribution network reconfiguration for operational objectives: reducing voltage violation incidents and network losses
Authors:
Geert Mangelschots,
Sari Kerckhove,
Md Umar Hashmi,
Dirk Van Hertem
Abstract:
As the share of Distributed energy resources (DER) in the low voltage distribution network (DN) is expected to rise, a higher and more variable electric load and generation could stress the DNs, leading to increased congestion and power losses. To address these challenges, DSOs will have to invest in strengthening the network infrastructure in the coming decade. This paper looks to minimize the ne…
▽ More
As the share of Distributed energy resources (DER) in the low voltage distribution network (DN) is expected to rise, a higher and more variable electric load and generation could stress the DNs, leading to increased congestion and power losses. To address these challenges, DSOs will have to invest in strengthening the network infrastructure in the coming decade. This paper looks to minimize the need for flexibility through dynamic DN reconfiguration. Typically, European DNs predominantly use manual switches. Hence, the network configuration is set for longer periods of time. Therefore, an opportunity is missed to benefit from more short-term dynamic switching. In this paper, a method is proposed which identifies the best manual switches to replace with remotely controlled switches based on their performance in terms of avoided voltage congestion incidents and DN power losses. The developed method is an exhaustive search algorithm which divides the problem into 3 subsequent parts, i.e. radial configuration identification, multi-period power flow and impact assessment for reconfigurable switch replacement on DN operation. A numerical evaluation shows that replacing the two top-ranked switches in the test case reduced the power losses by 4.51% and the voltage constraint violations by 38.17%. Thus, investing in only a few reconfigurable switches can substantially improve the operational efficiency of DNs.
△ Less
Submitted 14 September, 2024;
originally announced September 2024.
-
Linear energy storage and flexibility model with ramp rate, ramping, deadline and capacity constraints
Authors:
Md Umar Hashmi,
Dirk Van Hertem,
Aleen van der Meer,
Andrew Keane
Abstract:
The power networks are evolving with increased active components such as energy storage and flexibility derived from loads such as electric vehicles, heat pumps, industrial processes, etc. Better models are needed to accurately represent these assets; otherwise, their true capabilities might be over or under-estimated. In this work, we propose a new energy storage and flexibility arbitrage model t…
▽ More
The power networks are evolving with increased active components such as energy storage and flexibility derived from loads such as electric vehicles, heat pumps, industrial processes, etc. Better models are needed to accurately represent these assets; otherwise, their true capabilities might be over or under-estimated. In this work, we propose a new energy storage and flexibility arbitrage model that accounts for both ramp (power) and capacity (energy) limits, while accurately modelling the ramp rate constraint. The proposed models are linear in structure and efficiently solved using off-the-shelf solvers as a linear programming problem. We also provide an online repository for wider application and benchmarking. Finally, numerical case studies are performed to quantify the sensitivity of ramp rate constraint on the operational goal of profit maximization for energy storage and flexibility. The results are encouraging for assets with a slow ramp rate limit. We observe that for resources with a ramp rate limit of 10% of the maximum ramp limit, the marginal value of performing energy arbitrage using such resources exceeds 65% and up to 90% of the maximum profit compared to the case with no ramp rate limitations.
△ Less
Submitted 12 September, 2024;
originally announced September 2024.
-
Analyzing electric vehicle, load and photovoltaic generation uncertainty using publicly available datasets
Authors:
Md Umar Hashmi,
Domenico Gioffrè,
Simon Nagels,
Dirk Van Hertem
Abstract:
This paper aims to analyze three publicly available datasets for quantifying seasonal and annual uncertainty for efficient scenario creation. The datasets from Elaad, Elia and Fluvius are utilized to statistically analyze electric vehicle charging, normalized solar generation and low-voltage consumer load profiles, respectively. Frameworks for scenario generation are also provided for these datase…
▽ More
This paper aims to analyze three publicly available datasets for quantifying seasonal and annual uncertainty for efficient scenario creation. The datasets from Elaad, Elia and Fluvius are utilized to statistically analyze electric vehicle charging, normalized solar generation and low-voltage consumer load profiles, respectively. Frameworks for scenario generation are also provided for these datasets. The datasets for load profiles and solar generation analyzed are for the year 2022, thus embedding seasonal information. An online repository is created for the wider applicability of this work. Finally, the extreme load week(s) are identified and linked to the weather data measured at EnergyVille in Belgium.
△ Less
Submitted 2 September, 2024;
originally announced September 2024.
-
Impact of Dynamic Operating Envelopes on Distribution Network Hosting Capacity for Electric Vehicles
Authors:
Hossein Fani,
Md Umar Hashmi,
Emilio J. Palacios-Garcia,
Geert Deconinck
Abstract:
The examination of the maximum number of electric vehicles (EVs) that can be integrated into the distribution network (DN) without causing any operational incidents has become increasingly crucial as EV penetration rises. This issue can be addressed by utilizing dynamic operating envelopes (DOEs), which are generated based on the grid status. While DOEs improve the hosting capacity of the DN for E…
▽ More
The examination of the maximum number of electric vehicles (EVs) that can be integrated into the distribution network (DN) without causing any operational incidents has become increasingly crucial as EV penetration rises. This issue can be addressed by utilizing dynamic operating envelopes (DOEs), which are generated based on the grid status. While DOEs improve the hosting capacity of the DN for EVs (EV-HC) by restricting the operational parameters of the network, they also alter the amount of energy needed for charging each EV, resulting in a decrease in the quality of service (QoS). This study proposes a network-aware hosting capacity framework for EVs (EV-NAHC) that i) aims to assess the effects of DOEs on active distribution networks, ii) introduces a novel definition for HC and calculates the EV-NAHC based on the aggregated QoS of all customers. A small-scale Belgian feeder is utilized to examine the proposed framework. The results show a substantial increase in the EV-NAHC with low, medium, and high-daily charging energy scenarios.
△ Less
Submitted 4 June, 2024; v1 submitted 27 April, 2024;
originally announced April 2024.
-
Stochastic flexibility needs assessment: learnings from H2020 EUniversal's German demonstration
Authors:
Md Umar Hashmi,
Simon Nagels,
Dirk Van Hertem
Abstract:
Operational flexibility needs assessment (FNA) is crucial for system operators to plan/procure flexible resources in order to avoid probable network issues. We implemented an FNA tool in the framework of the H2020 EUniversal project for the German demonstration. In this work, we summarize our learnings from the demo implementation to cope with the limited availability of measurement data. Using a…
▽ More
Operational flexibility needs assessment (FNA) is crucial for system operators to plan/procure flexible resources in order to avoid probable network issues. We implemented an FNA tool in the framework of the H2020 EUniversal project for the German demonstration. In this work, we summarize our learnings from the demo implementation to cope with the limited availability of measurement data. Using a reduced network model and key performance indicators, we evaluate the digital-twin results with real-world implementations. The paper aims to motivate future research directions by duly considering real-world limitations in their modelling and developing innovative tailor-made solutions for an improved decision support framework for system operators.
△ Less
Submitted 20 November, 2023;
originally announced November 2023.
-
Multi-market Optimal Energy Storage Arbitrage with Capacity Blocking for Emergency Services
Authors:
Md Umar Hashmi,
Stephen Hardy,
Dirk Van Hertem,
Harsha Nagarajan
Abstract:
The future power system is increasingly interconnected via both AC and DC interconnectors. These interconnectors establish links between previously decoupled energy markets. In this paper, we propose an optimal multi-market energy storage arbitrage model that includes emergency service provisions for system operator(s). The model considers battery ramping and capacity constraints and utilizes oper…
▽ More
The future power system is increasingly interconnected via both AC and DC interconnectors. These interconnectors establish links between previously decoupled energy markets. In this paper, we propose an optimal multi-market energy storage arbitrage model that includes emergency service provisions for system operator(s). The model considers battery ramping and capacity constraints and utilizes operating envelopes calculated based on interconnector capacity, efficiency, dynamic energy injection and offshore wind generation in the day-ahead market. The arbitrage model considers two separate electricity prices for buying and selling of electricity in the two regions, connected via an interconnector. Using disjunctive linearization of nonlinear terms, we exactly reformulate the inter-regional energy arbitrage optimization as a mixed integer linear programming problem. We propose two capacity limit selection models for storage owners providing emergency services. The numerical analyses focus on two interconnections linking Belgium and the UK. The results are assessed based on revenue, operational cycles, payback period, shelf life and computation times.
△ Less
Submitted 1 October, 2023;
originally announced October 2023.
-
Robust dynamic operating envelopes for flexibility operation using only local voltage measurement
Authors:
Md Umar Hashmi,
Dirk Van Hertem
Abstract:
With growing intermittency and uncertainty in distribution networks around the world, ensuring operational integrity is becoming challenging. Recent use cases of dynamic operating envelopes (DOEs) indicate that they can be utilized for network awareness for autonomous operation of flexibility, maximizing distributed generation integration, coordinating flexibility in different power networks and i…
▽ More
With growing intermittency and uncertainty in distribution networks around the world, ensuring operational integrity is becoming challenging. Recent use cases of dynamic operating envelopes (DOEs) indicate that they can be utilized for network awareness for autonomous operation of flexibility, maximizing distributed generation integration, coordinating flexibility in different power networks and in resource planning. To this end, a novel framework is presented for generating decentralized DOEs in real-time using only the nodal voltage measurement and partially decentralized, risk-averse, robust DOEs in a time-ahead setting using voltage forecast scenarios. Chance constraint level is analytically implemented for avoiding extremely restrictive time-ahead DOEs with insufficient feasible regions for local energy optimization. Since the proposed DOE calculation framework uses none or limited centralized feedback, it is resilient to cyberattacks, communication failures, missing data and errors in network layout information. Numerical results showcase the DOE calculation framework in real-time using voltage magnitude measurements and in day-ahead timeframe using forecasted voltage scenarios. Furthermore, the DOEs are extended to form P-Q charts while considering power factor and converter capacity limits.
△ Less
Submitted 5 July, 2023; v1 submitted 22 May, 2023;
originally announced May 2023.
-
Consensus based phase connectivity identification for distribution network with limited observability
Authors:
Md Umar Hashmi,
David Brummund,
Rickard Lundholm,
Arpan Koirala,
Dirk Van Hertem
Abstract:
The mitigation of distribution network (DN) unbalance and the use of single-phase flexibility for congestion mitigation requires accurate phase connection information, which is often not available. For a large DN, the naive phase identification proposed in the majority of the prior works using a single voltage reference does not scale well for a multi-feeder DN. We present a consensus algorithm-ba…
▽ More
The mitigation of distribution network (DN) unbalance and the use of single-phase flexibility for congestion mitigation requires accurate phase connection information, which is often not available. For a large DN, the naive phase identification proposed in the majority of the prior works using a single voltage reference does not scale well for a multi-feeder DN. We present a consensus algorithm-based phase identification mechanism which uses multiple three-phase reference points to improve the prediction of phases. Due to the absence of real measurements for a real-suburban German DN, the algorithms are developed and evaluated over synthetic data using a digital twin. To utilize strongly correlated measurements, the DN is clustered into zones. We observe those reference measurements located in the same zone as the single-phase consumer leads to accurate prediction of DN phases. Four consensus algorithms are developed and compared. Using numerical results, we recommend the most robust phase identification mechanism. In our evaluation, measurement error, and the impact of the neutral conductor are also assessed. We assume limited DN observability and apply our findings to a German DN without smart meters, but only less than 8% of nodes have measurement boxes along with single-phase consumers with a home energy management system. Voltage time series for 1 month (hourly sampled) is utilized. The numerical results indicate that for 1% accuracy class measurement, the phase connectivity of 308 out of 313 single-phase consumers in a German DN can be identified. Further, we also propose metrics quantifying the goodness of the phase identification. The phase identification framework based on consensus algorithms for DN zones is scalable for large DN and robust towards measurement errors as the estimation is not dependent on a single measurement point.
△ Less
Submitted 10 January, 2023;
originally announced January 2023.
-
Optimal Operation of HVDC Interconnector: Irish Case
Authors:
Md Umar Hashmi
Abstract:
In September 2018 EirGrid launched the new electricity market. These new market arrangements integrate the all island electricity market with European electricity markets, making optimal use of cross border transmission assets. Ireland operates three operational HVDC interconnectors: Moyle, East-West, and Greenlink and one in development Celtic interconnector which connect Ireland to Scotland, Wal…
▽ More
In September 2018 EirGrid launched the new electricity market. These new market arrangements integrate the all island electricity market with European electricity markets, making optimal use of cross border transmission assets. Ireland operates three operational HVDC interconnectors: Moyle, East-West, and Greenlink and one in development Celtic interconnector which connect Ireland to Scotland, Wales, and France respectively. Irish market operator, EirGrid, can maximize their operational profit by using the price difference in these electricity markets. We propose a profit maximization modelling which considers the line losses and price difference in these different electricity markets and identifies the optimal import/export of power using HVDC interconnectors. These models in future should incorporate the distribution losses, renewable energy curtailment, and Irish power network congestion levels. The proposed modeling is the first step towards implementing a multi-objective HVDC interconnector operating strategy.
△ Less
Submitted 6 August, 2022;
originally announced August 2022.
-
Perspectives on distribution network flexible and curtailable resource activation and needs assessment
Authors:
Md Umar Hashmi,
Arpan Koirala,
Hakan Ergun,
Dirk Van Hertem
Abstract:
{A curtailable and flexible resource activation framework for solving distribution network (DN) voltage and thermal congestions is used to quantify three important aspects with respect to modelling low voltage networks.} This framework utilizes the network states in the absence of such flexible or curtailable resources as the input for calculating flexibility activation signal (FAS). The FAS has s…
▽ More
{A curtailable and flexible resource activation framework for solving distribution network (DN) voltage and thermal congestions is used to quantify three important aspects with respect to modelling low voltage networks.} This framework utilizes the network states in the absence of such flexible or curtailable resources as the input for calculating flexibility activation signal (FAS). The FAS has some similarities with optimal power flow duals {associated with power balance constraint}. FAS due to drooping design, {incentivize corrective flexibility activation} prior to any network limit violations. {The nonlinear resource dispatch optimal power flow (RDOPF) utilizes FAS for the activation of flexible and curtailable resources. Solving the OPF problem for a large system is computationally intensive, and second-order cone (SOC) relaxation is often applied in the literature.} {First,} we highlight the multi-objective nature of SOC relaxed RDOPF. A Pareto front tuning mechanism {is proposed for choosing loss penalty factor} while reducing the optimality gap of the SOC relaxed RDOPF. {Secondly, we} present a methodology for evaluating temporal and locational flexibility needs assessment of a DN, which DSO's can utilize for flexibility planning {in operational timescales and procurement in the flexibility market}. {Lastly, we} quantify the impact of reactive power flexibility for a DN with varying load power factors. {Numerical simulations indicate that the presence of reactive flexibility reduces the active power flexibility needs by 50\% for the test feeder with 0.8 aggregated load power factor.}
△ Less
Submitted 7 February, 2023; v1 submitted 21 July, 2022;
originally announced July 2022.
-
Can locational disparity of prosumer energy optimization due to inverter rules be limited?
Authors:
Md Umar Hashmi,
Deepjyoti Deka,
Ana Bušić,
Dirk Van Hertem
Abstract:
To mitigate issues related to the growth of variable smart loads and distributed generation, distribution system operators (DSO) now make it binding for prosumers with inverters to operate under pre-set rules. In particular, the maximum active and reactive power set points for prosumers are based on local voltage measurements to ensure that inverter output does not cause voltage violations. Howeve…
▽ More
To mitigate issues related to the growth of variable smart loads and distributed generation, distribution system operators (DSO) now make it binding for prosumers with inverters to operate under pre-set rules. In particular, the maximum active and reactive power set points for prosumers are based on local voltage measurements to ensure that inverter output does not cause voltage violations. However, such actions, as observed in this work, restrict the range available for local energy management, with more adverse losses on arbitrage profits for prosumers located farther away from the substation. The goal of the paper is three-fold: (a) to develop an optimal local energy optimization algorithm for activation of load flexibility and inverter-interfaced solar PV and energy storage under time-varying electricity prices; (b) to quantify the locational impact on prosumer arbitrage gains due to inverter injection rules prevalent in different energy markets; (c) to propose a computationally efficient hybrid inverter control policy which provides voltage regulation while substantially reducing locational disparity. Using numerical simulations on three identical prosumers located at different parts of a radial feeder, we show that our control policy is able to minimize locational disparity in arbitrage gains between customers at the beginning and end of the feeder to 1.4%, while PV curtailment is reduced by 91.7% compared to the base case with restrictive volt-Var and volt-watt policy.
△ Less
Submitted 18 November, 2022; v1 submitted 20 July, 2022;
originally announced July 2022.
-
Chance constrained day-ahead robust flexibility needs assessment for low voltage distribution network
Authors:
Md Umar Hashmi,
Arpan Koirala,
Hakan Ergun,
Dirk Van Hertem
Abstract:
For market-based procurement of low voltage (LV) flexibility, DSOs identify the amount of flexibility needed for resolving probable distribution network (DN) voltage and thermal congestion. A framework is required to avoid over or under procurement of flexibility in the presence of uncertainty. To this end, we propose a scenario-based robust chance-constrained (CC) day-ahead flexibility needs asse…
▽ More
For market-based procurement of low voltage (LV) flexibility, DSOs identify the amount of flexibility needed for resolving probable distribution network (DN) voltage and thermal congestion. A framework is required to avoid over or under procurement of flexibility in the presence of uncertainty. To this end, we propose a scenario-based robust chance-constrained (CC) day-ahead flexibility needs assessment (FNA) framework. The CC level is analogous to the risk DSO is willing to take in flexibility planning. Multi-period optimal power flow is performed to calculate the amount of flexibility needed to avoid network issues. Flexibility is defined in terms of nodal power ramp-up and ramp-down and cumulative energy needs over a full day for each node. Future uncertainties are considered as multiple scenarios generated using multivariate Gaussian distribution and Cholesky decomposition. These scenarios are utilized to solve the flexibility needs assessment optimal power flow (FNA-OPF) problem. Zonal clustering of an LV feeder is performed using electrical distance as a measure and spatial partitioning. The FNA tool calculates ramp-up and ramp-down flexibility's power and energy requirements. Energy and power needs are often valued differently in many energy markets. We identify the marginal value of flexibility associated with energy and power needs separately. From numerical results for an LV feeder, it is observed that zonal flexibility needs assessment is more immune to uncertainty than nodal flexibility needs, making it more useful for DSOs to evaluate day-ahead flexibility procurement. We also propose a Pareto optimal mechanism for selecting CC level to reduce flexibility needs while reducing DN congestion.
△ Less
Submitted 20 July, 2022;
originally announced July 2022.
-
Flexible and curtailable resource activation in three-phase unbalanced distribution networks
Authors:
Md Umar Hashmi,
Arpan Koirala,
Hakan Ergun,
Dirk Van Hertem
Abstract:
The need for flexibility and curtailable resources is crucial for ensuring the healthy operation of future distribution networks (DN). In this work, we propose a network-state driven framework that distribution system operators (DSOs) can utilize for activating flexible and curtailable resources for alleviating network voltage and thermal issues, while accounting for network voltage and current im…
▽ More
The need for flexibility and curtailable resources is crucial for ensuring the healthy operation of future distribution networks (DN). In this work, we propose a network-state driven framework that distribution system operators (DSOs) can utilize for activating flexible and curtailable resources for alleviating network voltage and thermal issues, while accounting for network voltage and current imbalances. This approach assumes the availability of dynamic network state information and uses nodal sensitivities for calculating a flexibility activation signal (FAS). The signal design is motivated by volt-Var and volt-watt inverter control, and thus bounded. The FAS also considers network voltage and current imbalances and incentivizes activation of active and reactive power flexibilities for reducing imbalance in addition to mitigating voltage and thermal imbalances in a three-phase unbalanced distribution network. The FAS design resembles optimal power flow duals, often used as locational marginal prices. The gains associated with the imbalance component of the objective function of three-phase unbalanced resource activation (TPU-RA) is performed using Pareto optimality. A numerical case study is presented showing the efficacy of the proposed framework in avoiding network issues while reducing voltage unbalance factor by more than 80\%. Further, DN's flexibility needs are quantified for location and time of day.
△ Less
Submitted 16 May, 2022;
originally announced May 2022.
-
WEcharge: democratizing EV charging infrastructure
Authors:
Md Umar Hashmi,
Mohammad Meraj Alam,
Ony Lalaina Valerie Ramarozatovo,
Mohammad Shadab Alam
Abstract:
The sustainable growth of EVs will have to be met with proportional growth in EV charging infrastructure. With limited urban spaces to place new charging stations, shrinking profitability, privately owned charging facilities need to be shared. WEcharge will allow privately owned charging infrastructure to be shared with public EV owners using a business model. We propose a resource matching algori…
▽ More
The sustainable growth of EVs will have to be met with proportional growth in EV charging infrastructure. With limited urban spaces to place new charging stations, shrinking profitability, privately owned charging facilities need to be shared. WEcharge will allow privately owned charging infrastructure to be shared with public EV owners using a business model. We propose a resource matching algorithm that takes into account incoming EV preferences, hard constraints for such EV, and provides the best suited resource for charging. We demonstrate the applicability of the matching model by showing a realistic case study with a Nissan Leaf 40 kW EV and 25 company and publicly owned charging stations (DC fast charger, AC rapid charger, level 1 and level 2 charger) in Hasselt, Belgium. The case study shows that consumer preferences will govern resource matching.
△ Less
Submitted 25 March, 2022;
originally announced April 2022.
-
Evaluation of voltage magnitude based unbalance metric for low voltage distribution networks
Authors:
Md Umar Hashmi,
Arpan Koirala,
Rickard Lundholm,
Hakan Ergun,
Dirk Van Hertem
Abstract:
Voltage unbalance in distribution networks (DN) is expected to grow with increasing penetration of single-phase distributed generation and single-phase loads such as electric vehicle chargers. Unbalance mitigation will be a significant concern as voltage unbalance leads to increased losses, reduced motor and inverter efficiency, and becomes a limiting factor for DN operation. The true definition o…
▽ More
Voltage unbalance in distribution networks (DN) is expected to grow with increasing penetration of single-phase distributed generation and single-phase loads such as electric vehicle chargers. Unbalance mitigation will be a significant concern as voltage unbalance leads to increased losses, reduced motor and inverter efficiency, and becomes a limiting factor for DN operation. The true definition of the unbalance metric needs phasor measurements of network voltage and current. However, such phasor measurements are generally not available in real life and as such approximate definitions are widely used due to their simplicity. This work aims to compare the true voltage unbalance definition and approximate unbalance metrics derived from phase voltage magnitude, as phase voltage magnitudes are commonly measured by digital metering infrastructure. For the comparison, multi-period power flow simulations are performed for 161 Spanish distribution feeders with R/X ratios varying from 2.87 to 14.68. We observe that phase magnitude-based unbalance metrics reasonably approximate the true unbalance for higher R/X ratios with a varying load power factor in a DN. Furthermore, the approximate unbalance metrics slightly improve for a low DN power factor due to the increase in DN unbalance. Therefore, the phase magnitude-based unbalance metric can be utilized for approximating DN unbalance.
△ Less
Submitted 19 February, 2022;
originally announced February 2022.
-
Impact of subsidy on profitability of residential photovoltaics, battery and inverter in Flanders
Authors:
Md Umar Hashmi,
Mohammed Meraj Alam
Abstract:
The sustained future growth of renewable energy in the distribution network is governed by its financial viability. The recent subsidies in Flanders for photovoltaic (PV) and battery are used to calculate the payback period on prosumer investment in residential PV, battery and inverter installations. Realistic scenario of PV, battery and inverter are created based on the market catalogue of one ma…
▽ More
The sustained future growth of renewable energy in the distribution network is governed by its financial viability. The recent subsidies in Flanders for photovoltaic (PV) and battery are used to calculate the payback period on prosumer investment in residential PV, battery and inverter installations. Realistic scenario of PV, battery and inverter are created based on the market catalogue of one manufacturer per product. Using these scenarios, one-year simulations for a residential prosumer are conducted in a rolling horizon. Luminus, an energy service provider in Limburg, time-of-use and feed-in-tariff contract rates are utilized. The numerical evaluation indicates that the policies prefer new PV installations. The subsidy comparison for 2021 to 2024 is also conducted. Oversizing PV compared to inverter size increases profitability. Batteries performing only arbitrage may not attract much investment, as the payback period is high. This shows the need to maximize the value addition of prosumer investment on residential batteries by participating in multiple goals.
△ Less
Submitted 17 November, 2021;
originally announced November 2021.
-
Energy Efficient Cross Layer Time Synchronization in Cognitive Radio Networks
Authors:
S. M. Usman Hashmi,
Muntazir Hussain,
S. M. Nashit Arshad,
Kashif Inayat,
Seong Oun Hwang
Abstract:
Time synchronization is a vital concern for any Cognitive Radio Network (CRN) to perform dynamic spectrum management. Each Cognitive Radio (CR) node has to be environment aware and self adaptive and must have the ability to switch between multiple modulation schemes and frequencies. Achieving same notion of time within these CR nodes is essential to fulfill the requirements for simultaneous quiet…
▽ More
Time synchronization is a vital concern for any Cognitive Radio Network (CRN) to perform dynamic spectrum management. Each Cognitive Radio (CR) node has to be environment aware and self adaptive and must have the ability to switch between multiple modulation schemes and frequencies. Achieving same notion of time within these CR nodes is essential to fulfill the requirements for simultaneous quiet periods for spectrum sensing. Current application layer time synchronization protocols require multiple timestamp exchanges to estimate skew between the clocks of CRN nodes. The proposed symbol timing recovery method already estimates the skew of hardware clock at the physical layer and use it for skew correction of application layer clock of each node. The heart of application layer clock is the hardware clock and hence application layer clock skew will be same as of physical layer and can be corrected from symbol timing recovery process. So one timestamp is enough to synchronize two CRN nodes. This conserves the energy utilized by application layer protocol and makes a CRN energy efficient and can achieve time synchronization in short span.
△ Less
Submitted 7 July, 2020;
originally announced July 2020.
-
Implementation of Symbol Timing Recovery for Estimation of Clock Skew
Authors:
S. M. Usman Hashmi,
Muntazir Hussain,
Fahad Bin Muslim,
Kashif Inayat,
Seong Oun Hwang
Abstract:
Time synchronization in any distributed network can be achieved by using application layer protocols for time correction. Time synchronization method proposed in this article uses symbol timing recovery at the physical layer to correct application layer clock. This cross layer methodology diminishes the quantity of message trades needed by application layer for time synchronization thus resulting…
▽ More
Time synchronization in any distributed network can be achieved by using application layer protocols for time correction. Time synchronization method proposed in this article uses symbol timing recovery at the physical layer to correct application layer clock. This cross layer methodology diminishes the quantity of message trades needed by application layer for time synchronization thus resulting in energy saving. Precision of skew estimate can be increased by using multiple message exchanges. Examination of the cross layer strategy including the simulation results, the experimentation outcomes and mathematical analysis demonstrates that clock skew at physical layer is same as of application layer, which is actually the skew of hardware clock within the node.
△ Less
Submitted 25 June, 2020;
originally announced June 2020.
-
Energy Storage Optimization for Grid Reliability
Authors:
Md Umar Hashmi,
Deepjyoti Deka,
Lucas Pereira,
Ana Busic
Abstract:
Large scale renewable energy integration is being planned for multiple power grids around the world. To achieve secure and stable grid operations, additional resources/reserves are needed to mitigate the inherent intermittency of renewable energy sources (RES). In this paper, we present formulations to understand the effect of fast storage reserves in improving grid reliability under different cos…
▽ More
Large scale renewable energy integration is being planned for multiple power grids around the world. To achieve secure and stable grid operations, additional resources/reserves are needed to mitigate the inherent intermittency of renewable energy sources (RES). In this paper, we present formulations to understand the effect of fast storage reserves in improving grid reliability under different cost functions. Our formulations and solution schemes not only aim to minimize imbalance but also maintain state-of-charge (SoC) of storage. In particular, we show that accounting for system response due to inertia and local governor response enables a more realistic quantification of storage requirements for damping net load fluctuations. The storage requirement is significantly lower than values determined when such traditional response are not accounted for. We demonstrate the performance of our designed policies through studies using real data from the Elia TSO in Belgium and BPA agency in the USA. The numerical results enable us to benchmark the marginal effect on reliability due to increasing storage size under different system responses and associated cost functions.
△ Less
Submitted 19 April, 2020;
originally announced April 2020.
-
Energy storage applications for low voltage consumers in Uruguay
Authors:
Md Umar Hashmi,
Jose Horta,
Diego Kiedanski,
Ana Bušić,
Daniel Kofman
Abstract:
Energy storage can be used for many applications in the Smart Grid such as energy arbitrage, peak demand shaving, power factor correction, energy backup to name a few, and can play a major role at increasing the capacity of power networks to host renewable energy sources. Often, storage control algorithms will need to be \textit{tailored} according to power networks billing structure, reliability…
▽ More
Energy storage can be used for many applications in the Smart Grid such as energy arbitrage, peak demand shaving, power factor correction, energy backup to name a few, and can play a major role at increasing the capacity of power networks to host renewable energy sources. Often, storage control algorithms will need to be \textit{tailored} according to power networks billing structure, reliability restrictions, and other local power networks norms. In this paper we explore residential energy storage applications in Uruguay, one of the global leaders in renewable energies, where new low-voltage consumer contracts were recently introduced. Based on these billing mechanisms, we focus on energy arbitrage and reactive energy compensation with the aim of minimizing the cost of consumption of an end-user. Given that in the new contacts the buying and selling price of electricity are equal and that reactive power compensation is primarily governed by the installed converter, the storage operation is not sensitive to parameter uncertainties and, therefore, no lookahead is required for decision making. A threshold-based \textit{hierarchical} controller is proposed which decides on the optimal active energy for arbitrage and uses the remaining converter capacity for reactive power compensation, which is shown to increase end-user profit. Numerical results indicate that storage could be profitable, even considering battery degradation, under some but not all of the studied contracts. For the cases in which it is not, we propose the best-suited contract. Results presented here can be naturally applied whenever the tariff structure satisfies the hypothesis considered in this work.
△ Less
Submitted 10 February, 2020;
originally announced February 2020.
-
Towards Phase Balancing using Energy Storage
Authors:
Md Umar Hashmi,
José Horta,
Lucas Pereira,
Zachary Lee,
Ana Bušić,
Daniel Kofman
Abstract:
Ad-hoc growth of single-phase-connected distributed energy resources, such as solar generation and electric vehicles, can lead to network unbalance with negative consequences on the quality and efficiency of electricity supply. Case-studies are presented for a substation in Madeira, Portugal and an EV charging facility in Pasadena, California. These case studies show that phase imbalance can happe…
▽ More
Ad-hoc growth of single-phase-connected distributed energy resources, such as solar generation and electric vehicles, can lead to network unbalance with negative consequences on the quality and efficiency of electricity supply. Case-studies are presented for a substation in Madeira, Portugal and an EV charging facility in Pasadena, California. These case studies show that phase imbalance can happen due to a large amount of distributed generation (DG) and electric vehicle (EV) integration. We conducted stylized load-flow analysis on a radial distribution network using an openDSS-based simulator to understand such negative effects of phase imbalance on neutral and phase conductor losses, and in voltage drop/rise. We evaluate the integration of storage in the distribution network as a possible solution for mitigating effects caused by imbalance. We present control architectures of storage operation for phase balancing. Numerically we show that relatively small-sized storage (compared to unbalance magnitude) can significantly reduce network imbalance. We identify the end node of the feeder as the best location to install storage.
△ Less
Submitted 10 February, 2020;
originally announced February 2020.
-
Storage Optimal Control under Net Metering Policies
Authors:
Md Umar Hashmi,
Arpan Mukhopadhyay,
Ana Bušić,
Jocelyne Elias
Abstract:
Electricity prices and the end user net load vary with time. Electricity consumers equipped with energy storage devices can perform energy arbitrage, i.e., buy when energy is cheap or when there is a deficit of energy, and sell it when it is expensive or in excess, taking into account future variations in price and net load. Net metering policies indicate that many of the utilities apply a {custom…
▽ More
Electricity prices and the end user net load vary with time. Electricity consumers equipped with energy storage devices can perform energy arbitrage, i.e., buy when energy is cheap or when there is a deficit of energy, and sell it when it is expensive or in excess, taking into account future variations in price and net load. Net metering policies indicate that many of the utilities apply a {customer selling} rate lower than or equal to the retail {customer buying rate} in order to compensate excess energy generated by end users. In this paper, we formulate the optimal control problem for an end user energy storage device in presence of net metering. We propose a computationally efficient algorithm, with worst case run time complexity of quadratic in terms of number of samples in lookahead horizon, that computes the optimal energy ramping rates in a time horizon. The proposed algorithm exploits the problem's piecewise linear structure and convexity properties for the \textit{discretization} of optimal Lagrange multipliers. The solution has a \textit{threshold-based structure} in which optimal control decisions are independent of past or future price as well as of net load values beyond a certain time horizon, defined as a \textit{sub-horizon}. Numerical results show the effectiveness of the proposed model and algorithm. Furthermore, we investigate the impact of forecasting errors on the proposed technique. We consider an Auto-Regressive Moving Average (ARMA) based forecasting of net load together with the Model Predictive Control (MPC). We numerically show that adaptive forecasting and MPC significantly mitigate the effects of forecast error on energy arbitrage gains.
△ Less
Submitted 4 February, 2020;
originally announced February 2020.
-
Sizing and Profitability of Energy Storage for Prosumers in Madeira, Portugal
Authors:
Md Umar Hashmi,
Jonathan Cavaleiro,
Lucas Pereira,
Ana Bušić
Abstract:
This paper proposes a framework to select the best-suited battery for co-optimizing for peak demand shaving, energy arbitrage and increase self-sufficiency in the context of power network in Madeira, Portugal. Feed-in-tariff for electricity network in Madeira is zero, which implies consumers with excess production should locally consume the excess generation rather than wasting it. Further, the po…
▽ More
This paper proposes a framework to select the best-suited battery for co-optimizing for peak demand shaving, energy arbitrage and increase self-sufficiency in the context of power network in Madeira, Portugal. Feed-in-tariff for electricity network in Madeira is zero, which implies consumers with excess production should locally consume the excess generation rather than wasting it. Further, the power network {operator} applies a peak power contract for consumers which imposes an upper bound on the peak power seen by the power grid interfaced by energy meter. We investigate the value of storage in Madeira, using four different types of prosumers, categorized based on the relationship between their inelastic load and renewable generation. We observe that the marginal increase in the value of storage deteriorates with increase in size and ramping capabilities. We propose the use of profit per cycle per unit of battery capacity and expected payback period as indices for selecting the best-suited storage parameters to ensure profitability. This mechanism takes into account the consumption and generation patterns, profit, storage degradation, and cycle and calendar life of the battery. We also propose the inclusion of a friction coefficient in the original co-optimization formulation to increase the value of storage by reducing the operational cycles and eliminate low returning transactions.
△ Less
Submitted 23 November, 2019;
originally announced November 2019.
-
Optimal Storage Arbitrage under Net Metering using Linear Programming
Authors:
Md Umar Hashmi,
Arpan Mukhopadhyay,
Ana Bušić,
Jocelyne Elias,
Diego Kiedanski
Abstract:
We formulate the optimal energy arbitrage problem for a piecewise linear cost function for energy storage devices using linear programming (LP). The LP formulation is based on the equivalent minimization of the epigraph. This formulation considers ramping and capacity constraints, charging and discharging efficiency losses of the storage, inelastic consumer load and local renewable generation in p…
▽ More
We formulate the optimal energy arbitrage problem for a piecewise linear cost function for energy storage devices using linear programming (LP). The LP formulation is based on the equivalent minimization of the epigraph. This formulation considers ramping and capacity constraints, charging and discharging efficiency losses of the storage, inelastic consumer load and local renewable generation in presence of net-metering which facilitates selling of energy to the grid and incentivizes consumers to install renewable generation and energy storage. We consider the case where the consumer loads, electricity prices, and renewable generations at different instances are uncertain. These uncertain quantities are predicted using an Auto-Regressive Moving Average (ARMA) model and used in a model predictive control (MPC) framework to obtain the arbitrage decision at each instance. In numerical results we present the sensitivity analysis of storage performing arbitrage with varying ramping batteries and different ratio of selling and buying price of electricity.
△ Less
Submitted 15 August, 2019; v1 submitted 1 May, 2019;
originally announced May 2019.
-
Energy Storage in Madeira, Portugal: Co-optimizing for Arbitrage, Self-Sufficiency, Peak Shaving and Energy Backup
Authors:
Md Umar Hashmi,
Lucas Pereira,
Ana Bušić
Abstract:
Energy storage applications are explored from a prosumer (consumers with generation) perspective for the island of Madeira in Portugal. These applications could also be relevant to other power networks. We formulate a convex co-optimization problem for performing arbitrage under zero feed-in tariff, increasing self-sufficiency by increasing self-consumption of locally generated renewable energy, p…
▽ More
Energy storage applications are explored from a prosumer (consumers with generation) perspective for the island of Madeira in Portugal. These applications could also be relevant to other power networks. We formulate a convex co-optimization problem for performing arbitrage under zero feed-in tariff, increasing self-sufficiency by increasing self-consumption of locally generated renewable energy, provide peak shaving and act as a backup power source during anticipated and scheduled power outages. Using real data from Madeira we perform short and long time-scale simulations in order to select end-user contract which maximizes their gains considering storage degradation based on operational cycles. We observe energy storage ramping capability decides peak shaving potential, fast ramping batteries can significantly reduce peak demand charge. The numerical experiment indicates that storage providing backup does not significantly reduce gains performing arbitrage and peak demand shaving. Furthermore, we also use AutoRegressive Moving Average (ARMA) forecasting along with Model Predictive Control (MPC) for real-time implementation of the proposed optimization problem in the presence of uncertainty.
△ Less
Submitted 19 August, 2019; v1 submitted 31 March, 2019;
originally announced April 2019.
-
Arbitrage with Power Factor Correction using Energy Storage
Authors:
Md Umar Hashmi,
Deepjyoti Deka,
Ana Busic,
Lucas Pereira,
Scott Backhaus
Abstract:
The importance of reactive power compensation for power factor (PF) correction will significantly increase with the large-scale integration of distributed generation interfaced via inverters producing only active power. In this work, we focus on co-optimizing energy storage for performing energy arbitrage as well as local power factor correction. The joint optimization problem is non-convex, but c…
▽ More
The importance of reactive power compensation for power factor (PF) correction will significantly increase with the large-scale integration of distributed generation interfaced via inverters producing only active power. In this work, we focus on co-optimizing energy storage for performing energy arbitrage as well as local power factor correction. The joint optimization problem is non-convex, but can be solved efficiently using a McCormick relaxation along with penalty-based schemes. Using numerical simulations on real data and realistic storage profiles, we show that energy storage can correct PF locally without reducing arbitrage profit. It is observed that active and reactive power control is largely decoupled in nature for performing arbitrage and PF correction (PFC). Furthermore, we consider a real-time implementation of the problem with uncertain load, renewable and pricing profiles. We develop a model predictive control based storage control policy using auto-regressive forecast for the uncertainty. We observe that PFC is primarily governed by the size of the converter and therefore, look-ahead in time in the online setting does not affect PFC noticeably. However, arbitrage profit are more sensitive to uncertainty for batteries with faster ramp rates compared to slow ramping batteries.
△ Less
Submitted 11 January, 2020; v1 submitted 14 March, 2019;
originally announced March 2019.
-
Online Thevenin Equivalent Parameter Estimation using Nonlinear and Linear Recursive Least Square Algorithm
Authors:
Md. Umar Hashmi,
Rahul Choudhary,
Jayesh G. Priolkar
Abstract:
This paper proposes method for detection, estimation of Thevenin equivalent parameters to describe power system behavior. Thevenin equivalent estimation is a challenge due to variation in system states caused by power flow in the network. Thevenin equivalent calculation based on changes in system with multiple sources integrated with grid, isolated distributed generator system is analysed and nonl…
▽ More
This paper proposes method for detection, estimation of Thevenin equivalent parameters to describe power system behavior. Thevenin equivalent estimation is a challenge due to variation in system states caused by power flow in the network. Thevenin equivalent calculation based on changes in system with multiple sources integrated with grid, isolated distributed generator system is analysed and nonlinear least square fit estimation technique for algorithm is adopted. Linear least square fit is used with a linearized model. Performance evaluation of proposed method is carried out through mathematical model, nonlinear and linear least square fit based algorithm technique and simulation through MATLAB/SIMULINK package. Accurate grid and source side impedance estimation technique is applicable for distributed generation sources interfaced with grid to improve dynamic response, stability, reliability when subjected to faults or any other disturbances in network. Algorithm can accurately estimate Thevenin equivalent of multiple sources connected in parallel simultaneously with voltage and current phasor measurements at point of common coupling. Mathematical analysis and simulation results validate the effectiveness of proposed method.
△ Less
Submitted 20 July, 2016;
originally announced October 2016.