-
Measurement of the pion form factor with CMD-3 detector and its implication to the hadronic contribution to muon (g-2)
Authors:
CMD-3 Collaboration,
:,
F. V. Ignatov,
R. R. Akhmetshin,
A. N. Amirkhanov,
A. V. Anisenkov,
V. M. Aulchenko,
N. S. Bashtovoy,
D. E. Berkaev,
A. E. Bondar,
A. V. Bragin,
S. I. Eidelman,
D. A. Epifanov,
L. B. Epshteyn,
A. L. Erofeev,
G. V. Fedotovich,
A. O. Gorkovenko,
F. J. Grancagnolo,
A. A. Grebenuk,
S. S. Gribanov,
D. N. Grigoriev,
V. L. Ivanov,
S. V. Karpov,
A. S. Kasaev,
V. F. Kazanin
, et al. (44 additional authors not shown)
Abstract:
The cross section of the process $e^+e^-\toπ^+π^-$ has been measured in the center-of-mass energy range from 0.32 to 1.2 GeV with the CMD-3 detector at the electron-positron collider VEPP-2000. The measurement is based on an integrated luminosity of about 88 pb$^{-1}$, of which 62 pb$^{-1}$ represent a complete dataset collected by CMD-3 at center-of-mass energies below 1 GeV. In the dominant regi…
▽ More
The cross section of the process $e^+e^-\toπ^+π^-$ has been measured in the center-of-mass energy range from 0.32 to 1.2 GeV with the CMD-3 detector at the electron-positron collider VEPP-2000. The measurement is based on an integrated luminosity of about 88 pb$^{-1}$, of which 62 pb$^{-1}$ represent a complete dataset collected by CMD-3 at center-of-mass energies below 1 GeV. In the dominant region near the $ρ$ resonance a systematic uncertainty of 0.7% was achieved. The implications of the presented results for the evaluation of the hadronic contribution to the anomalous magnetic moment of the muon are discussed.
△ Less
Submitted 5 June, 2024; v1 submitted 22 September, 2023;
originally announced September 2023.
-
Measurement of the $e^+e^-\toπ^+π^-$ cross section from threshold to 1.2 GeV with the CMD-3 detector
Authors:
CMD-3 Collaboration,
:,
F. V. Ignatov,
R. R. Akhmetshin,
A. N. Amirkhanov,
A. V. Anisenkov,
V. M. Aulchenko,
N. S. Bashtovoy,
D. E. Berkaev,
A. E. Bondar,
A. V. Bragin,
S. I. Eidelman,
D. A. Epifanov,
L. B. Epshteyn,
A. L. Erofeev,
G. V. Fedotovich,
A. O. Gorkovenko,
F. J. Grancagnolo,
A. A. Grebenuk,
S. S. Gribanov,
D. N. Grigoriev,
V. L. Ivanov,
S. V. Karpov,
A. S. Kasaev,
V. F. Kazanin
, et al. (44 additional authors not shown)
Abstract:
The cross section of the process $e^+e^-\toπ^+π^-$ has been measured in the center of mass energy range from 0.32 to 1.2 GeV with the CMD-3 detector at the electron-positron collider VEPP-2000. The measurement is based on a full dataset collected below 1 GeV during three data taking seasons, corresponding to an integrated luminosity of about 62 pb$^{-1}$. In the dominant $ρ$-resonance region, a sy…
▽ More
The cross section of the process $e^+e^-\toπ^+π^-$ has been measured in the center of mass energy range from 0.32 to 1.2 GeV with the CMD-3 detector at the electron-positron collider VEPP-2000. The measurement is based on a full dataset collected below 1 GeV during three data taking seasons, corresponding to an integrated luminosity of about 62 pb$^{-1}$. In the dominant $ρ$-resonance region, a systematic uncertainty of 0.7% has been reached. At energies around $φ$-resonance the $π^+π^-$ production cross section was measured for the first time with high beam energy resolution. The forward-backward charge asymmetry in the $π^+π^-$ production has also been measured. It shows a strong deviation from the theoretical prediction based on the conventional scalar quantum electrodynamics framework, and it is in good agreement with the generalized vector-meson-dominance and dispersive-based predictions. The impact of the presented results on the evaluation of the hadronic contribution to the anomalous magnetic moment of muon is discussed.
△ Less
Submitted 5 June, 2024; v1 submitted 17 February, 2023;
originally announced February 2023.
-
Charged particle identification with the liquid xenon calorimeter of the CMD-3 detector
Authors:
V. L. Ivanov,
G. V. Fedotovich,
R. R. Akhmetshin,
A. N. Amirkhanov,
A. V. Anisenkov,
V. M. Aulchenko,
N. S. Bashtovoy,
A. E. Bondar,
A. V. Bragin,
S. I. Eidelman,
D. A. Epifanov,
L. B. Epshteyn,
A. L. Erofeev,
S. E. Gayazov,
A. A. Grebenuk,
S. S. Gribanov,
D. N. Grigoriev,
F. V. Ignatov,
S. V. Karpov,
V. F. Kazanin,
A. A. Korobov,
A. N. Kozyrev,
E. A. Kozyrev,
P. P. Krokovny,
A. E. Kuzmenko
, et al. (21 additional authors not shown)
Abstract:
The paper describes a method of the charged particle identification, developed for the \mbox{CMD-3} detector, installed at the VEPP-2000 $e^{+}e^{-}$ collider. The method is based on the application of the boosted decision trees classifiers, trained for the optimal separation of electrons, muons, pions and kaons in the momentum range from 100 to $1200~{\rm MeV}/c$. The input variables for the clas…
▽ More
The paper describes a method of the charged particle identification, developed for the \mbox{CMD-3} detector, installed at the VEPP-2000 $e^{+}e^{-}$ collider. The method is based on the application of the boosted decision trees classifiers, trained for the optimal separation of electrons, muons, pions and kaons in the momentum range from 100 to $1200~{\rm MeV}/c$. The input variables for the classifiers are linear combinations of the energy depositions of charged particles in 12 layers of the liquid xenon calorimeter of the \mbox{CMD-3}. The event samples for training of the classifiers are taken from the simulation. Various issues of the detector response tuning in simulation and calibration of the calorimeter strip channels are considered. Application of the method is illustrated by the examples of separation of the $e^+e^-(γ)$ and $π^+π^-(γ)$ final states and of selection of the $K^+K^-$ final state at high energies.
△ Less
Submitted 12 August, 2020;
originally announced August 2020.
-
Measurement of the $e^{+}e^{-}\rightarrowηπ^{+}π^{-}$ cross section with the CMD-3 detector at the VEPP-2000 collider
Authors:
S. S. Gribanov,
A. S. Popov,
R. R. Akhmetshin,
A. N. Amirkhanov,
A. V. Anisenkov,
V. M. Aulchenko,
V. Sh. Banzarov,
N. S. Bashtovoy,
D. E. Berkaev,
A. E. Bondar,
A. V. Bragin,
S. I. Eidelman,
D. A. Epifanov,
L. B. Epshteyn,
A. L. Erofeev,
G. V. Fedotovich,
S. E. Gayazov,
F. J. Grancagnolo,
A. A. Grebenuk,
D. N. Grigoriev,
F. V. Ignatov,
V. L. Ivanov,
S. V. Karpov,
V. F. Kazanin,
A. N. Kirpotin
, et al. (35 additional authors not shown)
Abstract:
The cross section of the process $e^{+}e^{-}\rightarrowηπ^{+}π^{-}$ is measured using the data collected with the CMD-$3$ detector at the VEPP-$2000$ collider in the center-of-mass energy range from $1.1$ to $2.0$ GeV. The decay mode $η\rightarrowγγ$ is used for $η$ meson reconstruction in the data sample corresponding to an integrated luminosity of $78.3$ pb$^{-1}$. The energy dependence of the…
▽ More
The cross section of the process $e^{+}e^{-}\rightarrowηπ^{+}π^{-}$ is measured using the data collected with the CMD-$3$ detector at the VEPP-$2000$ collider in the center-of-mass energy range from $1.1$ to $2.0$ GeV. The decay mode $η\rightarrowγγ$ is used for $η$ meson reconstruction in the data sample corresponding to an integrated luminosity of $78.3$ pb$^{-1}$. The energy dependence of the $e^{+}e^{-}\rightarrowηπ^{+}π^{-}$ cross section is fitted within the framework of vector meson dominance in order to extract the $Γ(ρ(1450)\rightarrow{^{+}e^{-}})\mathcal{B}(ρ(1450)\rightarrowηπ^{+}π^{-})$ and the $Γ(ρ(1700)\rightarrow{e^{+}e^{-}})\mathcal{B}(ρ(1700)\rightarrowηπ^{+}π^{-})$ products. Based on conservation of vector current, the analysed data are used to test the relationship between the $e^{+}e^{-}\rightarrowηπ^{+}π^{-}$ cross section and the spectral function in $τ^-\rightarrowηπ^-π^0ν_τ$ decay. The $e^{+}e^{-}\rightarrowηπ^{+}π^{-}$ cross section measured with the CMD-$3$ detector is in good agreement with the previous measurements.
△ Less
Submitted 28 January, 2020; v1 submitted 18 July, 2019;
originally announced July 2019.
-
Study of the process $e^+e^-{\to}K^+K^-η$ with the CMD-3 detector at the VEPP-2000 collider
Authors:
V. L. Ivanov,
G. V. Fedotovich,
R. R. Akhmetshin,
A. N. Amirkhanov,
A. V. Anisenkov,
V. M. Aulchenko,
V. Sh. Banzarov,
N. S. Bashtovoy,
D. E. Berkaev,
A. E. Bondar,
A. V. Bragin,
S. I. Eidelman,
D. A. Epifanov,
L. B. Epshteyn,
A. L. Erofeev,
S. E. Gayazov,
A. A. Grebenuk,
S. S. Gribanov,
D. N. Grigoriev,
F. V. Ignatov,
S. V. Karpov,
A. S. Kasaev,
V. F. Kazanin,
I. A. Koop,
A. A. Korobov
, et al. (31 additional authors not shown)
Abstract:
The process $e^+e^-{\to}K^+K^-η$ has been studied in the center-of-mass energy range from 1.59 to 2.007\,GeV using the data sample of 59.5 pb$^{-1}$, collected with the CMD-3 detector at the VEPP-2000 $e^+e^-$ collider in 2011, 2012 and 2017. The $K^+K^-η$ final state is found to be dominated by the contribution of the $φ(1020)η$ intermediate state. The cross section of the process…
▽ More
The process $e^+e^-{\to}K^+K^-η$ has been studied in the center-of-mass energy range from 1.59 to 2.007\,GeV using the data sample of 59.5 pb$^{-1}$, collected with the CMD-3 detector at the VEPP-2000 $e^+e^-$ collider in 2011, 2012 and 2017. The $K^+K^-η$ final state is found to be dominated by the contribution of the $φ(1020)η$ intermediate state. The cross section of the process $e^+e^-{\to}φ(1020)η$ has been measured with a systematic uncertainty of 5.1$\%$ on the base of 3009 $\pm$ 67 selected events. The obtained cross section has been used to calculate the contribution to the anomalous magnetic moment of the muon: $a_μ^{φη}(E<1.8\, {\rm GeV})=(0.321 \pm 0.015_{\rm stat} \pm 0.016_{\rm syst}) \times 10^{-10}$, $a_μ^{φη}(E<2.0\, {\rm GeV})=(0.440 \pm 0.015_{\rm stat} \pm 0.022_{\rm syst}) \times 10^{-10}$. From the cross section approximation the $φ(1680)$ meson parameters have been determined with better statistical precision, than in previous studies.
△ Less
Submitted 13 September, 2019; v1 submitted 19 June, 2019;
originally announced June 2019.
-
Study of the process $e^+e^- \to K^+K^-$ in the center-of-mass energy range 1010--1060~MeV with the CMD-3 detector
Authors:
E. A. Kozyrev,
E. P. Solodov,
R. R. Akhmetshin,
A. N. Amirkhanov,
A. V. Anisenkov,
V. M. Aulchenko,
V. S. Banzarov,
N. S. Bashtovoy,
D. E. Berkaev,
A. E. Bondar,
A. V. Bragin,
S. I. Eidelman,
D. A. Epifanov,
L. B. Epshteyn,
A. L. Erofeev,
G. V. Fedotovich,
S. E. Gayazov,
A. A. Grebenuk,
S. S. Gribanov,
D. N. Grigoriev,
F. V. Ignatov,
V. L. Ivanov,
S. V. Karpov,
A. S. Kasaev,
V. F. Kazanin
, et al. (28 additional authors not shown)
Abstract:
The process $e^+e^- \to K^+K^-$ has been studied using $1.7 \times 10^6$ events from a data sample corresponding to an integrated luminosity of 5.7 pb$^{-1}$ collected with the CMD-3 detector in the center-of-mass energy range 1010--1060 MeV. The cross section measured with an about 2\% systematic uncertainty and it is used to calculate the contribution to the anomalous magnetic moment of the muon…
▽ More
The process $e^+e^- \to K^+K^-$ has been studied using $1.7 \times 10^6$ events from a data sample corresponding to an integrated luminosity of 5.7 pb$^{-1}$ collected with the CMD-3 detector in the center-of-mass energy range 1010--1060 MeV. The cross section measured with an about 2\% systematic uncertainty and it is used to calculate the contribution to the anomalous magnetic moment of the muon $a_μ^{K^+K^-} = (19.33 \pm 0.40) \times 10^{-10}$, and to obtain the $φ(1020)$ meson parameters. We consider the relationship between the $e^+e^- \to K^+K^-$ and $e^+e^- \to K^0_SK^0_L$ cross sections and compare it to the theoretical expectations.
△ Less
Submitted 9 October, 2017;
originally announced October 2017.
-
Study of the Process $e^+e^-\to π^+π^-π^+π^-$ IN THE C.M. Energy Range 920--1060 MeV with the CMD-3 Detector
Authors:
R. R. Akhmetshin,
A. N. Amirkhanov,
A. V. Anisenkov,
V. M. Aulchenko,
V. Sh. Banzarov,
N. S. Bashtovoy,
D. E. Berkaev,
A. E. Bondar,
A. V. Bragin,
S. I. Eidelman,
D. A. Epifanov,
L. B. Epshteyn,
A. L. Erofeev,
G. V. Fedotovich,
S. E. Gayazov,
A. A. Grebenuk,
S. S. Gribanov,
D. N. Grigoriev,
F. V. Ignatov,
V. L. Ivanov,
S. V. Karpov,
A. S. Kasaev,
V. F. Kazanin,
I. A. Koop,
O. A. Kovalenko
, et al. (30 additional authors not shown)
Abstract:
A cross section of the process $e^+e^- \to \pipi\pipi$ has been measured using 6798$\pm$93 signal events from a data sample corresponding to an integrated luminosity of 9.8 pb$^{-1}$ collected with the CMD-3 detector in the center-of-mass energy range 920--1060 MeV. The measured cross section exhibits an interference pattern of the $φ(1020)\to\pipi\pipi$ decay with a non-resonant process…
▽ More
A cross section of the process $e^+e^- \to \pipi\pipi$ has been measured using 6798$\pm$93 signal events from a data sample corresponding to an integrated luminosity of 9.8 pb$^{-1}$ collected with the CMD-3 detector in the center-of-mass energy range 920--1060 MeV. The measured cross section exhibits an interference pattern of the $φ(1020)\to\pipi\pipi$ decay with a non-resonant process $e^+e^- \to \pipi\pipi$, from which we obtain the branching fraction of the doubly suppressed decays (by G-parity and OZI rule): $\BR(φ\to\pipi\pipi) = (6.5\pm2.7\pm1.6)\times 10^{-6}$.
△ Less
Submitted 27 December, 2016; v1 submitted 13 December, 2016;
originally announced December 2016.
-
Measurement of the $e^+e^- \to K^+K^-π^+π^-$ cross section with the CMD-3 detector at the VEPP-2000 collider
Authors:
D. N. Shemyakin,
G. V. Fedotovich,
R. R. Akhmetshin,
A. N. Amirkhanov,
A. V. Anisenkov,
V. M. Aulchenko,
V. Sh. Banzarov,
N. S. Bashtovoy,
A. E. Bondar,
A. V. Bragin,
S. I. Eidelman,
D. A. Epifanov,
L. B. Epshteyn,
A. L. Erofeev,
S. E. Gayazov,
A. A. Grebenuk,
S. S. Gribanov,
D. N. Grigoriev,
F. V. Ignatov,
V. L. Ivanov,
S. V. Karpov,
V. F. Kazanin,
I. A. Koop,
A. A. Korobov,
O. A. Kovalenko
, et al. (29 additional authors not shown)
Abstract:
The process $e^+e^- \to K^+K^-π^+π^-$ has been studied in the center-of-mass energy range from 1500 to 2000\,MeV using a data sample of 23 pb$^{-1}$ collected with the CMD-3 detector at the VEPP-2000 $e^+e^-$ collider. Using about 24000 selected events, the $e^+e^- \to K^+K^-π^+π^-$ cross section has been measured with a systematic uncertainty decreasing from 11.7\% at 1500-1600\,MeV to 6.1\% abov…
▽ More
The process $e^+e^- \to K^+K^-π^+π^-$ has been studied in the center-of-mass energy range from 1500 to 2000\,MeV using a data sample of 23 pb$^{-1}$ collected with the CMD-3 detector at the VEPP-2000 $e^+e^-$ collider. Using about 24000 selected events, the $e^+e^- \to K^+K^-π^+π^-$ cross section has been measured with a systematic uncertainty decreasing from 11.7\% at 1500-1600\,MeV to 6.1\% above 1800\,MeV. A preliminary study of $K^+K^-π^+π^-$ production dynamics has been performed.
△ Less
Submitted 20 February, 2016; v1 submitted 2 October, 2015;
originally announced October 2015.
-
Study of the process $e^+e^-\to p\bar{p}$ in the c.m. energy range from threshold to 2 GeV with the CMD-3 detector
Authors:
R. R. Akhmetshin,
A. N. Amirkhanov,
A. V. Anisenkov,
V. M. Aulchenko,
V. Sh. Banzarov,
N. S. Bashtovoy,
D. E. Berkaev,
A. E. Bondar,
A. V. Bragin,
S. I. Eidelman,
D. A. Epifanov,
L. B. Epshteyn,
A. L. Erofeev,
G. V. Fedotovich,
S. E. Gayazov,
A. A. Grebenuk,
S. S. Gribanov,
D. N. Grigoriev,
E. M. Gromov,
F. V. Ignatov,
V. L. Ivanov,
S. V. Karpov,
A. S. Kasaev,
V. F. Kazanin,
B. I. Khazin
, et al. (34 additional authors not shown)
Abstract:
Using a data sample of 6.8 pb$^{-1}$ collected with the CMD-3 detector at the VEPP-2000 $e^+e^-$ collider we select about 2700 events of the $e^+e^- \to p\bar{p}$ process and measure its cross section at 12 energy ponts with about 6\% systematic uncertainty. From the angular distribution of produced nucleons we obtain the ratio $|G_{E}/G_{M}| = 1.49 \pm 0.23 \pm 0.30$.
Using a data sample of 6.8 pb$^{-1}$ collected with the CMD-3 detector at the VEPP-2000 $e^+e^-$ collider we select about 2700 events of the $e^+e^- \to p\bar{p}$ process and measure its cross section at 12 energy ponts with about 6\% systematic uncertainty. From the angular distribution of produced nucleons we obtain the ratio $|G_{E}/G_{M}| = 1.49 \pm 0.23 \pm 0.30$.
△ Less
Submitted 13 April, 2016; v1 submitted 29 July, 2015;
originally announced July 2015.
-
Search for the process $e^+e^-\to η^\prime(958)$ with the CMD-3 detector
Authors:
R. R. Akhmetshin,
A. V. Anisenkov,
V. M. Aulchenko,
V. Sh. Banzarov,
N. S. Bashtovoy,
D. E. Berkaeva,
A. E. Bondar,
A. V. Bragin,
S. I. Eidelman,
D. A. Epifanov,
L. B. Epshteyn,
A. L. Erofeev,
G. V. Fedotovich,
S. E. Gayazov,
A. A. Grebenuk,
D. N. Grigoriev,
E. N. Gromov,
F. V. Ignatov,
S. V. Karpov,
V. F. Kazanin,
B. I. Khazin,
I. A. Koop,
O. A. Kovalenko,
A. N. Kozyrev,
E. A. Kozyrev
, et al. (29 additional authors not shown)
Abstract:
A search for the process $\epem\to η^\prime(958)$ in the $\pipiη\to\pipiγγ$ final state has been performed with the CMD-3 detector at the VEPP-2000 $e^+e^-$ collider. Using an integrated luminosity of 2.69 pb$^{-1}$ collected at the center-of-mass energy \Ecm = 957.68 MeV we set an upper limit for the product of electronic width and branching fractions…
▽ More
A search for the process $\epem\to η^\prime(958)$ in the $\pipiη\to\pipiγγ$ final state has been performed with the CMD-3 detector at the VEPP-2000 $e^+e^-$ collider. Using an integrated luminosity of 2.69 pb$^{-1}$ collected at the center-of-mass energy \Ecm = 957.68 MeV we set an upper limit for the product of electronic width and branching fractions $Γ_{η^\prime(958)\to\epem}\cdot\BR_{η^\prime(958)\to\pipiη}\cdot\BR_{η\toγγ}<0.00041$ eV at 90\% C.L.
△ Less
Submitted 27 October, 2014; v1 submitted 5 September, 2014;
originally announced September 2014.
-
First demonstration of THGEM/GAPD-matrix optical readout in two-phase Cryogenic Avalanche Detector in Ar
Authors:
A. Bondar,
A. Buzulutskov,
A. Dolgov,
A. Grebenuk,
E. Shemyakina,
A. Sokolov,
A. Breskin,
D. Thers
Abstract:
The multi-channel optical readout of a THGEM multiplier coupled to a matrix of 3x3 Geiger-mode APDs (GAPDs) was demonstrated in a two-phase Cryogenic Avalanche Detector (CRAD) in Ar. The GAPDs recorded THGEM-hole avalanches in the Near Infrared (NIR). At an avalanche charge gain of 160, the yield of the combined THGEM/GAPD-matrix multiplier amounted at ~80 photoelectrons per 20 keV X-ray absorbed…
▽ More
The multi-channel optical readout of a THGEM multiplier coupled to a matrix of 3x3 Geiger-mode APDs (GAPDs) was demonstrated in a two-phase Cryogenic Avalanche Detector (CRAD) in Ar. The GAPDs recorded THGEM-hole avalanches in the Near Infrared (NIR). At an avalanche charge gain of 160, the yield of the combined THGEM/GAPD-matrix multiplier amounted at ~80 photoelectrons per 20 keV X-ray absorbed in the liquid phase. A spatial resolution of 2.5 mm (FWHM) has been measured for the impinging X-rays. This technique has potential applications in coherent neutrino-nucleus scattering and dark matter search experiments.
△ Less
Submitted 19 March, 2013;
originally announced March 2013.
-
Study of the process $e^+e^-\to 3(π^+π^-)$ in the c.m.energy range 1.5--2.0 gev with the cmd-3 detector
Authors:
CMD-3 Collaboration,
:,
R. R. Akhmetshin,
A. V. Anisenkov,
S. A. Anokhin,
V. M. Aulchenko,
V. S. Banzarov,
L. M. Barkov,
N. S. Bashtovoy,
D. E. Berkaev,
A. E. Bondar,
A. V. Bragin,
S. I. Eidelman,
D. A. Epifanov,
L. B. Epshteyn,
G. V. Fedotovich,
S. E. Gayazov,
A. A. Grebenuk,
D. N. Grigoriev,
E. N. Gromov,
F. V. Ignatov,
S. V. Karpov,
V. F. Kazanin,
B. I. Khazin,
I. A. Koop
, et al. (34 additional authors not shown)
Abstract:
The cross section of the process $e^+e^- \to 3(π^+π^-)$ has been measured using 22 pb$^{-1}$ of integrated luminosity collected with the CMD-3 detector at the VEPP-2000 $e^+e^-$ collider in the c.m. energy range 1.5 -- 2.0 GeV. The measured cross section exhibits a sharp drop near the $p\bar p$ threshold. A first study of dynamics of six-pion production has been performed.
The cross section of the process $e^+e^- \to 3(π^+π^-)$ has been measured using 22 pb$^{-1}$ of integrated luminosity collected with the CMD-3 detector at the VEPP-2000 $e^+e^-$ collider in the c.m. energy range 1.5 -- 2.0 GeV. The measured cross section exhibits a sharp drop near the $p\bar p$ threshold. A first study of dynamics of six-pion production has been performed.
△ Less
Submitted 31 January, 2013;
originally announced February 2013.
-
Two-phase Cryogenic Avalanche Detectors with THGEM and hybrid THGEM/GEM multipliers operated in Ar and Ar+N2
Authors:
A. Bondar,
A. Buzulutskov,
A. Dolgov,
A. Grebenuk,
E. Shemyakina,
A. Sokolov,
D. Akimov,
A. Breskin,
D. Thers
Abstract:
Two-phase Cryogenic Avalanche Detectors (CRADs) with GEM and THGEM multipliers have become an emerging potential technique for charge recording in rare-event experiments. In this work we present the performance of two-phase CRADs operated in Ar and Ar+N2. Detectors with sensitive area of 10x10 cm2, reaching a litre-scale active volume, yielded gains of the order of 1000 with a double-THGEM multipl…
▽ More
Two-phase Cryogenic Avalanche Detectors (CRADs) with GEM and THGEM multipliers have become an emerging potential technique for charge recording in rare-event experiments. In this work we present the performance of two-phase CRADs operated in Ar and Ar+N2. Detectors with sensitive area of 10x10 cm2, reaching a litre-scale active volume, yielded gains of the order of 1000 with a double-THGEM multiplier. Higher gains, of about 5000, have been attained in two-phase Ar CRADs with a hybrid triple-stage multiplier, comprising of a double-THGEM followed by a GEM. The performance of two-phase CRADs in Ar doped with N2 (0.1-0.6%) yielded faster signals and similar gains compared to the operation in two-phase Ar. The applicability to rare-event experiments is discussed.
△ Less
Submitted 2 October, 2012;
originally announced October 2012.
-
Study of infrared scintillations in gaseous and liquid argon - Part II: light yield and possible applications
Authors:
A. Bondar,
A. Buzulutskov,
A. Dolgov,
A. Grebenuk,
S. Peleganchuk,
V. Porosev,
L. Shekhtman,
E. Shemyakina,
A. Sokolov
Abstract:
We present here a comprehensive study of the light yield of primary and secondary scintillations produced in gaseous and liquid Ar in the near infrared (NIR) and visible region, at cryogenic temperatures. The measurements were performed using Geiger-mode avalanche photodiodes (GAPDs) and pulsed X-ray irradiation. The primary scintillation yield of the fast emission component in gaseous Ar was foun…
▽ More
We present here a comprehensive study of the light yield of primary and secondary scintillations produced in gaseous and liquid Ar in the near infrared (NIR) and visible region, at cryogenic temperatures. The measurements were performed using Geiger-mode avalanche photodiodes (GAPDs) and pulsed X-ray irradiation. The primary scintillation yield of the fast emission component in gaseous Ar was found to be independent of temperature in the range of 87-160 K; it amounted to 17000+/-3000 photon/MeV in the NIR in the range of 690-1000 nm. In liquid Ar at 87 K, the primary scintillation yield of the fast component was considerably reduced, amounting to 510+/-90 photon/MeV, in the range of 400-1000 nm. Proportional NIR scintillations (electroluminescence) in gaseous Ar were also observed; their amplification parameter at 160 K was measured to be 13 photons per drifting electron per kV. No proportional scintillations were observed in liquid Ar up to the electric fields of 30 kV/cm. The applications of NIR scintillations in dark matter search and coherent neutrino-nucleus scattering experiments and in ion beam radiotherapy are considered.
△ Less
Submitted 28 May, 2012; v1 submitted 2 April, 2012;
originally announced April 2012.
-
Study of infrared scintillations in gaseous and liquid argon - Part I: methodology and time measurements
Authors:
A. Bondar,
A. Buzulutskov,
A. Dolgov,
A. Grebenuk,
E. Shemyakina,
A. Sokolov
Abstract:
A methodology to measure Near Infrared (NIR) scintillations in gaseous and liquid Ar, using Geiger-mode APDs (GAPDs) sensitive in the NIR and pulsed X-ray irradiation, is described. This study has been triggered by the development of Cryogenic Avalanche Detectors (CRADs) with optical readout in the NIR using combined THGEM/GAPD multiplier, which may come to be in demand in coherent neutrino-nucleu…
▽ More
A methodology to measure Near Infrared (NIR) scintillations in gaseous and liquid Ar, using Geiger-mode APDs (GAPDs) sensitive in the NIR and pulsed X-ray irradiation, is described. This study has been triggered by the development of Cryogenic Avalanche Detectors (CRADs) with optical readout in the NIR using combined THGEM/GAPD multiplier, which may come to be in demand in coherent neutrino-nucleus scattering and dark matter search experiments. A new approach to measure the NIR scintillation yield at cryogenic temperatures has been developed, namely using GAPDs in single photoelectron counting mode with time resolution. The time structure of NIR scintillations and their light yield were measured both for primary scintillations and that of secondary at moderate electric fields (electroluminescence), in gaseous and liquid Ar.
△ Less
Submitted 1 April, 2012;
originally announced April 2012.
-
On the low-temperature performances of THGEM and THGEM/G-APD multipliers in gaseous and two-phase Xe
Authors:
A. Bondar,
A. Buzulutskov,
A. Grebenuk,
E. Shemyakina,
A. Sokolov,
D. Akimov,
I. Alexandrov,
A. Breskin
Abstract:
The performances of THGEM multipliers in two-phase Xe avalanche mode are presented for the first time. Additional results on THGEM operation in gaseous Xe at cryogenic temperatures are provided. Stable operation of a double-THGEM multiplier was demonstrated in two-phase Xe with gains reaching 600. These are compared to existing data, summarized here for two-phase Ar, Kr and Xe avalanche detectors…
▽ More
The performances of THGEM multipliers in two-phase Xe avalanche mode are presented for the first time. Additional results on THGEM operation in gaseous Xe at cryogenic temperatures are provided. Stable operation of a double-THGEM multiplier was demonstrated in two-phase Xe with gains reaching 600. These are compared to existing data, summarized here for two-phase Ar, Kr and Xe avalanche detectors incorporating GEM and THGEM multipliers. The optical readout of THGEMs with Geiger-mode Avalanche Photodiodes (G-APDs) has been investigated in gaseous Xe at cryogenic temperature; avalanche scintillations were recorded in the Near Infrared (NIR) at wavelengths of up to 950 nm. At avalanche charge gain of 350, the double-THGEM/G-APD multiplier yielded 0.07 photoelectrons per initial ionization electron, corresponding to an avalanche scintillation yield of 0.7 NIR photons per avalanche electron over 4pi. The results are compared with those of two-phase Ar avalanche detectors. The advantages, limitations and possible applications are discussed.
△ Less
Submitted 21 July, 2011; v1 submitted 31 March, 2011;
originally announced March 2011.
-
Infrared scintillation yield in gaseous and liquid argon
Authors:
A. Buzulutskov,
A. Bondar,
A. Grebenuk
Abstract:
The study of primary and secondary scintillations in noble gases and liquids is of paramount importance to rare-event experiments using noble gas media. In the present work, the scintillation yield in gaseous and liquid Ar has for the first time been measured in the near infrared (NIR) and visible region, both for primary and secondary (proportional) scintillations, using Geiger-mode avalanche pho…
▽ More
The study of primary and secondary scintillations in noble gases and liquids is of paramount importance to rare-event experiments using noble gas media. In the present work, the scintillation yield in gaseous and liquid Ar has for the first time been measured in the near infrared (NIR) and visible region, both for primary and secondary (proportional) scintillations, using Geiger-mode avalanche photodiodes (G-APDs) and pulsed X-ray irradiation. The primary scintillation yield of the fast component was measured to be 17000 photon/MeV in gaseous Ar in the NIR, in the range of 690-1000 nm, and 510 photon/MeV in liquid Ar, in the range of 400-1000 nm. Proportional NIR scintillations (electroluminescence) in gaseous Ar have been also observed; their amplification parameter at 163 K was measured to be 13 photons per drifting electron per kV. Possible applications of NIR scintillations in high energy physics experiments are discussed.
△ Less
Submitted 19 April, 2011; v1 submitted 9 February, 2011;
originally announced February 2011.
-
Measurement of $φ$(1020) meson leptonic width with CMD-2 detector at VEPP-2M Collider
Authors:
R. R. Akhmetshin,
V. M. Aulchenko,
V. Sh. Banzarov,
L. M. Barkov,
S. E. Baru,
N. S. Bashtovoy,
A. E. Bondar,
A. V. Bragin,
S. I. Eidelman,
D. A. Epifanov,
G. V. Fedotovich,
N. I. Gabyshev,
A. A. Grebenuk,
D. N. Grigoriev,
F. V. Ignatov,
S. V. Karpov,
V. F. Kazanin,
B. I. Khazin,
I. A. Koop,
P. P. Krokovny,
A. S. Kuzmin,
I. B. Logashenko,
P. A. Lukin,
A. P. Lysenko,
K. Yu. Mikhailov
, et al. (12 additional authors not shown)
Abstract:
The $φ$(1020) meson leptonic width has been determined from the combined analysis of 4 major decay modes of the resonance ($φ\to K^+ K^-,K^0_LK^0_S,π^+π^-π^0,ηγ$) studied with the CMD-2 detector at the VEPP-2M $e^+e^-$ collider. The following value has been obtained: $Γ(φ\to e^+e^-) = 1.235\pm 0.006\pm 0.022$ keV.
The $φ(1020)$ meson parameters in four main decay channels have been also recalcul…
▽ More
The $φ$(1020) meson leptonic width has been determined from the combined analysis of 4 major decay modes of the resonance ($φ\to K^+ K^-,K^0_LK^0_S,π^+π^-π^0,ηγ$) studied with the CMD-2 detector at the VEPP-2M $e^+e^-$ collider. The following value has been obtained: $Γ(φ\to e^+e^-) = 1.235\pm 0.006\pm 0.022$ keV.
The $φ(1020)$ meson parameters in four main decay channels have been also recalculated: $B(φ\to K^+K^-) = 0.493\pm 0.003\pm 0.007$, $B(φ\to K_LK_S) = 0.336\pm 0.002\pm 0.006$, $B(φ\toπ^+π^-π^0) = 0.155\pm 0.002\pm 0.005$, $B(φ\toηγ) = 0.0138\pm 0.0002\pm 0.0002$.
△ Less
Submitted 16 November, 2010; v1 submitted 23 October, 2010;
originally announced October 2010.
-
Direct observation of avalanche scintillations in a THGEM-based two-phase Ar avalanche detector using Geiger-mode APD
Authors:
A. Bondar,
A. Buzulutskov,
A. Grebenuk,
A. Sokolov,
D. Akimov,
I. Alexandrov,
A. Breskin
Abstract:
A novel concept of optical signal recording in two-phase avalanche detectors, with Geiger-mode Avalanche Photodiodes (G-APD) is described. Avalanche-scintillation photons were measured in a thick Gas Electron Multiplier (THGEM) in view of potential applications in rare-event experiments. The effective detection of avalanche scintillations in THGEM holes has been demonstrated in two-phase Ar with a…
▽ More
A novel concept of optical signal recording in two-phase avalanche detectors, with Geiger-mode Avalanche Photodiodes (G-APD) is described. Avalanche-scintillation photons were measured in a thick Gas Electron Multiplier (THGEM) in view of potential applications in rare-event experiments. The effective detection of avalanche scintillations in THGEM holes has been demonstrated in two-phase Ar with a bare G-APD without wavelength shifter, i.e. insensitive to VUV emission of Ar. At gas-avalanche gain of 400 and under \pm 70^\circ viewing-angle, the G-APD yielded 640 photoelectrons (pe) per 60 keV X-ray converted in liquid Ar; this corresponds to 0.7 pe per initial (prior to multiplication) electron. The avalanche-scintillation light yield measured by the G-APD was about 0.7 pe per avalanche electron, extrapolated to 4pi acceptance. The avalanche scintillations observed occurred presumably in the near infrared (NIR) where G-APDs may have high sensitivity. The measured scintillation yield is similar to that observed by others in the VUV. Other related topics discussed in this work are the G-APD's single-pixel and quenching resistor characteristics at cryogenic temperatures.
△ Less
Submitted 28 May, 2010;
originally announced May 2010.
-
Geiger Mode APD performance in a cryogenic two-phase Ar avalanche detector based on THGEMs
Authors:
A. Bondar,
A. Buzulutskov,
A. Grebenuk,
A. Sokolov,
D. Akimov,
I. Alexandrov,
A. Breskin
Abstract:
Characteristic properties of a Geiger Mode APD (G-APD) in a THGEM-based cryogenic two-phase Ar avalanche detector were studied in view of potential applications in rare-event experiments. G-APD signal amplitude and noise characteristics at cryogenic temperatures turned out to be superior to those at room temperature. The effective detection of avalanche scintillations from THGEM-multiplier holes i…
▽ More
Characteristic properties of a Geiger Mode APD (G-APD) in a THGEM-based cryogenic two-phase Ar avalanche detector were studied in view of potential applications in rare-event experiments. G-APD signal amplitude and noise characteristics at cryogenic temperatures turned out to be superior to those at room temperature. The effective detection of avalanche scintillations from THGEM-multiplier holes in two-phase Ar has been demonstrated using a G-APD without wavelength shifter. At an avalanche gain of 60, the avalanche scintillation yield measured by the G-APD was as high as 0.9 photoelectrons per avalanche electron, extrapolated to 4pi acceptance.
△ Less
Submitted 27 May, 2010; v1 submitted 8 March, 2010;
originally announced March 2010.
-
Electron emission properties of two-phase argon and argon-nitrogen avalanche detectors
Authors:
A. Bondar,
A. Buzulutskov,
A. Grebenuk,
D. Pavlyuchenko,
Y. Tikhonov
Abstract:
Electron emission properties of two-phase Ar avalanche detectors are studied. The detectors investigated comprised a liquid Ar or Ar+N2 layer followed by a multi-GEM multiplier operated in the saturated vapour at 84 K. Two components of the electron emission through the liquid-gas interface were observed: fast and slow. In Ar, the slow emission component dominated even at higher fields, reaching…
▽ More
Electron emission properties of two-phase Ar avalanche detectors are studied. The detectors investigated comprised a liquid Ar or Ar+N2 layer followed by a multi-GEM multiplier operated in the saturated vapour at 84 K. Two components of the electron emission through the liquid-gas interface were observed: fast and slow. In Ar, the slow emission component dominated even at higher fields, reaching 2 kV/cm. In Ar+N2 on the contrary, the fast emission component dominated at higher fields, the slow component being disappeared. This is explained by the electron backscattering effect in the gas phase. The slow component decay time constant was inversely proportional to the electric field, which is compatible with thermionic emission model. The electron emission efficiencies in two-phase Ar and Ar+N2 were estimated to be close to each other.
△ Less
Submitted 20 August, 2009;
originally announced August 2009.
-
Recent results on the properties of two-phase argon avalanche detectors
Authors:
A. Bondar,
A. Buzulutskov,
A. Grebenuk,
D. Pavlyuchenko,
Y. Tikhonov
Abstract:
The characteristic properties of two-phase Ar avalanche detectors, including those obtained with CsI photocathode, are further studied. Such detectors are relevant in the field of coherent neutrino-nucleus scattering and dark matter search experiments. The detectors investigated comprised a 1 cm thick liquid Ar layer followed by a triple-GEM multiplier. In these detectors, typical gains reaching…
▽ More
The characteristic properties of two-phase Ar avalanche detectors, including those obtained with CsI photocathode, are further studied. Such detectors are relevant in the field of coherent neutrino-nucleus scattering and dark matter search experiments. The detectors investigated comprised a 1 cm thick liquid Ar layer followed by a triple-GEM multiplier. In these detectors, typical gains reaching 10000 were obtained with good reproducibility and a stable operation for at least one day was demonstrated. Amplitude and pulse-shape characteristics are presented under irradiation with X-rays, gamma-rays and neutrons from different radioactive sources. The detection of both primary scintillation and ionization signals at higher gains, at a deposited energy of 60 keV, has been demonstrated.
△ Less
Submitted 3 July, 2008;
originally announced July 2008.
-
Thick GEM versus thin GEM in two-phase argon avalanche detectors
Authors:
A. Bondar,
A. Buzulutskov,
A. Grebenuk,
D. Pavlyuchenko,
Y. Tikhonov,
A. Breskin
Abstract:
The performance of thick GEMs (THGEMs) was compared to that of thin GEMs in two-phase Ar avalanche detectors, in view of their potential application in coherent neutrino-nucleus scattering, dark-matter search and in other rare-event experiments. The detectors comprised a 1 cm thick liquid-Ar layer followed by either a double-THGEM or a triple-GEM multiplier, operated in the saturated vapor above…
▽ More
The performance of thick GEMs (THGEMs) was compared to that of thin GEMs in two-phase Ar avalanche detectors, in view of their potential application in coherent neutrino-nucleus scattering, dark-matter search and in other rare-event experiments. The detectors comprised a 1 cm thick liquid-Ar layer followed by either a double-THGEM or a triple-GEM multiplier, operated in the saturated vapor above the liquid phase. Three types of THGEMs were studied: those made of G10 and Kevlar and that with resistive electrodes (RETHGEM). Only the G10-made THGEM showed a stable performance in two-phase Ar with gains reaching 3000. Successful operation of two-phase Ar avalanche detectors with either thin- or thick-GEM multipliers was demonstrated at low detection thresholds, of 4 and 20 primary electrons respectively. Compared to the triple-GEM the double-THGEM multiplier yielded slower anode signals; this allowed applying a pulse-shape analysis to effectively reject noise signals. Noise rates of both multipliers were evaluated in two-phase Ar; with detection thresholds of 20 electrons and applying pulse-shape analysis noise levels as low as 0.007 Hz per 1 cm2 of active area were reached.
△ Less
Submitted 14 May, 2008;
originally announced May 2008.
-
First results of the two-phase argon avalanche detector performance with CsI photocathode
Authors:
A. Bondar,
A. Buzulutskov,
A. Grebenuk,
D. Pavlyuchenko,
R. Snopkov,
Y. Tikhonov
Abstract:
The performance of a two-phase Ar avalanche detector with CsI photocathode was studied, with regard to potential application in coherent neutrino-nucleus scattering and dark matter search experiments. The detector comprised a 1 cm thick liquid Ar layer and a triple-GEM multiplier operated in the saturated vapor above the liquid phase; the CsI photocathode was deposited on the first GEM. Successf…
▽ More
The performance of a two-phase Ar avalanche detector with CsI photocathode was studied, with regard to potential application in coherent neutrino-nucleus scattering and dark matter search experiments. The detector comprised a 1 cm thick liquid Ar layer and a triple-GEM multiplier operated in the saturated vapor above the liquid phase; the CsI photocathode was deposited on the first GEM. Successful detection of both primary scintillation and ionization signals, produced by beta-particles in liquid Ar, has for the first time been demonstrated in the two-phase avalanche mode.
△ Less
Submitted 27 February, 2007;
originally announced February 2007.
-
A two-phase argon avalanche detector operated in a single electron counting mode
Authors:
A. Bondar,
A. Buzulutskov,
A. Grebenuk,
D. Pavlyuchenko,
R. Snopkov,
Y. Tikhonov,
V. A. Kudryavtsev,
P. K. Lightfoot,
N. J. C. Spooner
Abstract:
The performance of a two-phase Ar avalanche detector in a single electron counting mode was studied, with regard to potential application in coherent neutrino-nucleus scattering and dark matter search experiments. The detector comprised of a 1 cm thick liquid Ar layer and a triple-GEM multiplier operated in the saturated vapour above the liquid phase. Successful operation of the detector in sing…
▽ More
The performance of a two-phase Ar avalanche detector in a single electron counting mode was studied, with regard to potential application in coherent neutrino-nucleus scattering and dark matter search experiments. The detector comprised of a 1 cm thick liquid Ar layer and a triple-GEM multiplier operated in the saturated vapour above the liquid phase. Successful operation of the detector in single electron counting mode, in the gain range from 6000 to 40000, has for the first time been demonstrated.
△ Less
Submitted 7 November, 2006;
originally announced November 2006.
-
High-statistics measurement of the pion form factor in the rho-meson energy range with the CMD-2 detector
Authors:
The CMD-2 Collaboration,
:,
R. R. Akhmetshin,
V. M. Aulchenko,
V. Sh. Banzarov,
L. M. Barkov,
N. S. Bashtovoy,
A. E. Bondar,
D. V. Bondarev,
A. V. Bragin,
S. K. Dhawan,
S. I. Eidelman,
D. A. Epifanov,
G. V. Fedotovich,
N. I. Gabyshev,
D. A. Gorbachev,
A. A. Grebenuk,
D. N. Grigoriev,
V. W. Hughes,
F. V. Ignatov,
S. V. Karpov,
V. F. Kazanin,
B. I. Khazin,
I. A. Koop,
P. P. Krokovny
, et al. (31 additional authors not shown)
Abstract:
We present a measurement of the pion form factor based on e+e- annihilation data from the CMD-2 detector in the energy range 0.6<sqrt(s)<1.0 GeV with a systematic uncertainty of 0.8%. A data sample is five times larger than that used in our previous measurement.
We present a measurement of the pion form factor based on e+e- annihilation data from the CMD-2 detector in the energy range 0.6<sqrt(s)<1.0 GeV with a systematic uncertainty of 0.8%. A data sample is five times larger than that used in our previous measurement.
△ Less
Submitted 28 January, 2007; v1 submitted 9 October, 2006;
originally announced October 2006.
-
Measurement of the e+e- -> pi+pi- cross section with the CMD-2 detector in the 370-520 MeV c.m. energy range
Authors:
R. R. Akhmetshin,
V. M. Aulchenko,
V. Sh. Banzarov,
L. M. Barkov,
N. S. Bashtovoy,
A. E. Bondar,
D. V. Bondarev,
A. V. Bragin,
S. K. Dhawan,
S. I. Eidelman,
D. A. Epifanov,
G. V. Fedotovich,
N. I. Gabyshev,
D. A. Gorbachev,
A. A. Grebenuk,
D. N. Grigoriev,
V. W. Hughes,
F. V. Ignatov,
S. V. Karpov,
V. F. Kazanin,
B. I. Khazin,
I. A. Koop,
P. P. Krokovny,
A. S. Kuzmin,
I. B. Logashenko
, et al. (28 additional authors not shown)
Abstract:
The cross section of the process e+e- -> pi+pi- has been measured at the CMD-2 detector in the 370-520 MeV center-of-mass (c.m.) energy range. A systematic uncertainty of the measurement is 0.7 %. Using all CMD-2 data on the pion form factor, the pion electromagnetic radius was calculated. The cross section of muon pair production was also determined.
The cross section of the process e+e- -> pi+pi- has been measured at the CMD-2 detector in the 370-520 MeV center-of-mass (c.m.) energy range. A systematic uncertainty of the measurement is 0.7 %. Using all CMD-2 data on the pion form factor, the pion electromagnetic radius was calculated. The cross section of muon pair production was also determined.
△ Less
Submitted 6 October, 2006; v1 submitted 6 October, 2006;
originally announced October 2006.
-
Two-phase argon and xenon avalanche detectors based on Gas Electron Multipliers
Authors:
A. Bondar,
A. Buzulutskov,
A. Grebenuk,
D. Pavlyuchenko,
R. Snopkov,
Y. Tikhonov
Abstract:
We study the performance of two-phase avalanche detectors based on Gas Electron Multipliers (GEMs) and operated in an electron-avalanching mode in Ar and Xe. Emission, gain, energy resolution and stability characteristics of the detectors were studied. Rather high gains, reaching 5000, and stable operation for several hours were observed in the two-phase Ar avalanche detector using a triple-GEM…
▽ More
We study the performance of two-phase avalanche detectors based on Gas Electron Multipliers (GEMs) and operated in an electron-avalanching mode in Ar and Xe. Emission, gain, energy resolution and stability characteristics of the detectors were studied. Rather high gains, reaching 5000, and stable operation for several hours were observed in the two-phase Ar avalanche detector using a triple-GEM multiplier. The signals induced by X-rays, beta-particles and gamma-rays were successfully recorded. Preliminary results were obtained in the two-phase Xe avalanche detector: the maximum gain of the triple-GEM in two-phase Xe and Xe+2%CH4 was about 200. The results obtained are relevant in the field of two-phase detectors for dark matter searches, coherent neutrino scattering, PET and digital radiography.
△ Less
Submitted 30 October, 2005;
originally announced October 2005.
-
Absorption of Scintillation Light in a 100 $\ell$ Liquid Xenon$γ$ Ray Detector and Expected Detector Performance
Authors:
A. Baldini,
C. Bemporad,
F. Cei,
T. Doke,
M. Grassi,
A. A. Grebenuk,
D. N. Grigoriev,
T. Haruyama,
K. Kasami,
J. Kikuchi,
A. Maki,
T. Mashimo,
S. Mihara,
T. Mitsuhashi,
T. Mori,
D. Nicolo`,
H. Nishiguchi,
W. Ootani,
K. Ozone,
A. Papa,
R. Pazzi,
S. Ritt,
R. Sawada,
F. Sergiampietri,
G. Signorelli
, et al. (6 additional authors not shown)
Abstract:
An 800L liquid xenon scintillation $γ$ ray detector is being developed for the MEG experiment which will search for $μ^+\to\mathrm{e}^+γ$ decay at the Paul Scherrer Institut. Absorption of scintillation light of xenon by impurities might possibly limit the performance of such a detector. We used a 100L prototype with an active volume of 372x372x496 mm$^3$ to study the scintillation light absorpt…
▽ More
An 800L liquid xenon scintillation $γ$ ray detector is being developed for the MEG experiment which will search for $μ^+\to\mathrm{e}^+γ$ decay at the Paul Scherrer Institut. Absorption of scintillation light of xenon by impurities might possibly limit the performance of such a detector. We used a 100L prototype with an active volume of 372x372x496 mm$^3$ to study the scintillation light absorption. We have developed a method to evaluate the light absorption, separately from elastic scattering of light, by measuring cosmic rays and $α$ sources. By using a suitable purification technique, an absorption length longer than 100 cm has been achieved. The effects of the light absorption on the energy resolution are estimated by Monte Carlo simulation.
△ Less
Submitted 6 July, 2004;
originally announced July 2004.
-
Reanalysis of Hadronic Cross Section Measurements at CMD-2
Authors:
R. R. Akhmetshin,
E. V. Anashkin,
A. B. Arbuzov,
V. Sh. Banzarov,
A. Baratt,
L. M. Barkov,
A. V. Bogdan,
A. E. Bondar,
D. V. Bondarev,
S. I. Eidelman,
D. A. Epifanov,
G. V. Fedotovich,
N. I. Gabyshev,
D. A. Gorbachev,
A. A. Grebenuk,
D. N. Grigoriev,
V. W. Hughes,
F. V. Ignatov,
V. F. Kazanin,
B. I. Khazin,
P. P. Krokovny,
E. A. Kuraev,
L. M. Kurdadze,
A. S. Kuzmin,
Yu. E. Lischenko
, et al. (20 additional authors not shown)
Abstract:
The updated results of the precise measurements of the processes e+e-->rho->pi+pi-, e+e-->omega->pi+pi-pi0 and e+e-->phi->KLKS performed by the CMD-2 collaboration are presented. The update appeared necessary due an overestimate of the integrated luminosity in previous analyses.
The updated results of the precise measurements of the processes e+e-->rho->pi+pi-, e+e-->omega->pi+pi-pi0 and e+e-->phi->KLKS performed by the CMD-2 collaboration are presented. The update appeared necessary due an overestimate of the integrated luminosity in previous analyses.
△ Less
Submitted 20 August, 2003; v1 submitted 5 August, 2003;
originally announced August 2003.