Multipacting Processing in Cryomodules For LCLS-II And LCLS-II-HE
Authors:
A. Cravatta,
T. Arkan,
D. Bafia,
J. Kaluzny,
S. Posen,
J. Vennekate,
M. Drury,
S. Aderhold,
M. Checchin,
D. Gonnella,
J. Hogan,
J. Maniscalco,
J. Nelson,
R. Porter,
L. Zacarias
Abstract:
Multipacting (MP) is a phenomenon which can affect stability in particle accelerators and limit performance in superconducting radio frequency cavities. In the TESLA shaped, 1.3 GHz, 9-cell cavities used in the LCLS-II (L2) and LCLS-II-HE (HE) projects, the MP-band (~17-24 MV/m) lies within the required accelerating gradients. For HE, the operating gradient of 20.8 MV/m lies well within the MP-ban…
▽ More
Multipacting (MP) is a phenomenon which can affect stability in particle accelerators and limit performance in superconducting radio frequency cavities. In the TESLA shaped, 1.3 GHz, 9-cell cavities used in the LCLS-II (L2) and LCLS-II-HE (HE) projects, the MP-band (~17-24 MV/m) lies within the required accelerating gradients. For HE, the operating gradient of 20.8 MV/m lies well within the MP-band and cryomodule testing has confirmed that this is an issue. As such, MP processing for the HE cryomodule test program will be discussed. Early results on MP processing in cryomodules installed in the L2 linac will also be presented, demonstrating that the methods used in cryomodule acceptance testing are also successful at conditioning MP in the accelerator and that this processing is preserved in the mid-term.
△ Less
Submitted 29 June, 2023;
originally announced June 2023.
-
Evaluation of predictive correlation between flux expulsion and grain growth for superconducting radio frequency cavities
Authors:
Zu Hawn Sung,
Paulina Kulyavtsev,
Martina Martinello,
Dan Gonnella,
Marc Ross,
Sam Posen
Abstract:
A series of experiments were carried out in an effort to develop a simple method for predicting magnetic flux expulsion behavior of high purity niobium used to fabricate superconducting radio frequency (SRF) cavities. Using conventional metallographic characterizations in conjunction with high spatial resolution electron backscattered diffraction-orientation imaging microscopy (EBSD-OIM), we found…
▽ More
A series of experiments were carried out in an effort to develop a simple method for predicting magnetic flux expulsion behavior of high purity niobium used to fabricate superconducting radio frequency (SRF) cavities. Using conventional metallographic characterizations in conjunction with high spatial resolution electron backscattered diffraction-orientation imaging microscopy (EBSD-OIM), we found that the flux expulsion behavior of 1.3 GHz single cell SRF Nb cavities is significantly associated with the grain growth of the Nb material during heat treatment. Most of Nb grains rapidly grew during 900C heat treatment, and likely full-recrystallized with 1000C HT. With comparison of the magnetic flux expulsion ratio (Bsc/Bnc) at dT = 5 K, the flux expulsion efficiency of the cavities increases along with increasing of grain size. Most interestingly, 900C HT shows a roughly linear trend that suggests this criterion could be used to predict appropriate heat treatment temperature for sufficient flux expulsion behavior in SRF-grade Nb. This result would be used to see if flux expulsion can be predicted by examining the materials coming from the Nb vendor, prior to cavity fabrication.
△ Less
Submitted 24 March, 2023;
originally announced March 2023.
-
Narrow bandwidth active noise control for microphonics rejection in superconducting cavities at LCLS-II
Authors:
Andrea Bellandi,
Julien Branlard,
Jorge Diaz Cruz,
Sebastian Aderhold,
Andrew Benwell,
Axel Brachmann,
Sonya Hoobler,
Alessandro Ratti,
Dan Gonnella,
Janice Nelson,
Ryan Douglas Porter,
Lisa Zacarias
Abstract:
LCLS-II is an X-Ray Free Electron Laser (XFEL) commissioned in 2022, being the first Continuous Wave (CW) hard XFEL in the world to come into operation. To accelerate the electron beam to an energy of $\SI{4}{\giga \eV}$, 280 TESLA type superconducting RF (SRF) cavities are used. A loaded quality factor ($Q_L$) of $4 \times 10^7$ is used to drive the cavities at a power level of a few kilowatts. F…
▽ More
LCLS-II is an X-Ray Free Electron Laser (XFEL) commissioned in 2022, being the first Continuous Wave (CW) hard XFEL in the world to come into operation. To accelerate the electron beam to an energy of $\SI{4}{\giga \eV}$, 280 TESLA type superconducting RF (SRF) cavities are used. A loaded quality factor ($Q_L$) of $4 \times 10^7$ is used to drive the cavities at a power level of a few kilowatts. For this $Q_L$, the RF cavity bandwidth is 32 Hz. Therefore, keeping the cavity resonance frequency within such bandwidth is imperative to avoid a significant increase in the required drive power. In superconducting accelerators, resonance frequency variations are produced by mechanical microphonic vibrations of the cavities. One source of microphonic noise is rotary machinery such as vacuum pumps or HVAC equipment. A possible method to reject these disturbances is to use Narrowband Active Noise Control (NANC) techniques. These techniques were already tested at DESY/CMTB and Cornell/CBETA. This proceeding presents the implementation of a NANC controller adapted to the LCLS-II Low Level RF (LLRF) control system. Tests showing the rejection of LCLS-II microphonic disturbances are also presented.
△ Less
Submitted 11 October, 2022; v1 submitted 28 September, 2022;
originally announced September 2022.
-
Key directions for research and development of superconducting radio frequency cavities
Authors:
S. Belomestnykh,
S. Posen,
D. Bafia,
S. Balachandran,
M. Bertucci,
A. Burrill,
A. Cano,
M. Checchin,
G. Ciovati,
L. D. Cooley,
G. Dalla Lana Semione,
J. Delayen,
G. Eremeev,
F. Furuta,
F. Gerigk,
B. Giaccone,
D. Gonnella,
A. Grassellino,
A. Gurevich,
W. Hillert,
M. Iavarone,
J. Knobloch,
T. Kubo,
W. K. Kwok,
R. Laxdal
, et al. (31 additional authors not shown)
Abstract:
Radio frequency superconductivity is a cornerstone technology for many future HEP particle accelerators and experiments from colliders to proton drivers for neutrino facilities to searches for dark matter. While the performance of superconducting RF (SRF) cavities has improved significantly over the last decades, and the SRF technology has enabled new applications, the proposed HEP facilities and…
▽ More
Radio frequency superconductivity is a cornerstone technology for many future HEP particle accelerators and experiments from colliders to proton drivers for neutrino facilities to searches for dark matter. While the performance of superconducting RF (SRF) cavities has improved significantly over the last decades, and the SRF technology has enabled new applications, the proposed HEP facilities and experiments pose new challenges. To address these challenges, the field continues to generate new ideas and there seems to be a vast room for improvements. In this paper we discuss the key research directions that are aligned with and address the future HEP needs.
△ Less
Submitted 21 August, 2022; v1 submitted 3 April, 2022;
originally announced April 2022.
-
Plasma Processing for In-Situ Field Emission Mitigation of Superconducting Radiofrequency (SRF) Cryomodules
Authors:
M. Martinello,
P. Berrutti,
B. Giaccone,
S. Belomestnykh,
M. Checchin,
G. V. Eremeev,
A. Grassellino,
T. Khabibouilline,
A. Netepenko,
R. Pilipenko,
A. Romanenko,
S. Posen,
G. Wu,
D. Gonnella,
M. Ross,
J. T. Maniscalco,
T. Powers
Abstract:
Field emission (FE) is one of the main limiting factors of superconducting radio-frequency (SRF) cavities operating in accelerators and it occurs whenever contaminants, like dust, metal flakes or even absorbates, are present on the surface of the cavity high electric field region. Field emission reduces the maximum achievable accelerating field and generates free electrons that may interact with t…
▽ More
Field emission (FE) is one of the main limiting factors of superconducting radio-frequency (SRF) cavities operating in accelerators and it occurs whenever contaminants, like dust, metal flakes or even absorbates, are present on the surface of the cavity high electric field region. Field emission reduces the maximum achievable accelerating field and generates free electrons that may interact with the beam, damage or activate the beamline. One practical method that can be used to mitigate this problem is in-situ plasma cleaning, or plasma processing. The development of a processing that can be applied in-situ is extremely advantageous, since it enables the recovery of the cryomodule performance without the need of disassembling the whole cryomodule, which is an extremely expensive and time-consuming process. On the other hand, plasma processing only requires the cryomodule warm-up to room-temperature and the subsequent processing of the contaminated cavities. The entire process is reasonably quick and involves a limited number of personnel. For these reasons we would like to advocate for continuing to invest in the R\&D of plasma processing to optimize its applicability in cryomodules and for extending the technique to other frequency ranges and cavities geometries.
△ Less
Submitted 23 March, 2022;
originally announced March 2022.
-
Plasma Cleaning of LCLS-II-HE verification cryomodule cavities
Authors:
Bianca Giaccone,
Paolo Berrutti,
Martina Martinello,
Sam Posen,
Andrew Cravatta,
Alexandr Netepenko,
Tug Arkan,
Anna Grassellino,
Brian Hartsell,
Joshua Kaluzny,
Andrew Penhollow,
Dan Gonnella,
Marc Ross,
James Maniscalco,
Joel Fuerst,
Greg Hays,
Marc Doleans
Abstract:
Plasma cleaning is a technique that can be applied in superconducting radio-frequency (SRF) cavities in situ in cryomodules in order to decrease their level of field emission. We developed the technique for the Linac Coherent Light Source II (LCLS-II) cavities and we present in this paper the full development and application of plasma processing to the LCLS-II High Energy (HE) verification cryomod…
▽ More
Plasma cleaning is a technique that can be applied in superconducting radio-frequency (SRF) cavities in situ in cryomodules in order to decrease their level of field emission. We developed the technique for the Linac Coherent Light Source II (LCLS-II) cavities and we present in this paper the full development and application of plasma processing to the LCLS-II High Energy (HE) verification cryomodule (vCM). We validated our plasma processing procedure on the vCM, fully processing four out of eight cavities of this CM, demonstrating that cavities performance were preserved in terms of both accelerating field and quality factor. Applying plasma processing to this clean, record breaking cryomodule also showed that no contaminants were introduced in the string, maintaining the vCM field emission-free up to the maximum field reached by each cavity. We also found that plasma processing eliminates multipacting (MP) induced quenches that are typically observed frequently within the MP band field range. This suggests that plasma processing could be employed in situ in CMs to mitigate both field emission and multipacting, significantly decreasing the testing time of cryomodules, the linac commissioning time and cost and increasing the accelerator reliability.
△ Less
Submitted 1 June, 2022; v1 submitted 24 January, 2022;
originally announced January 2022.
-
LCLS-II-HE verification cryomodule high gradient performance and quench behavior
Authors:
S. Posen,
A. Cravatta,
M. Checchin,
S. Aderhold,
C. Adolphsen,
T. Arkan,
D. Bafia,
A. Benwell,
D. Bice,
B. Chase,
C. Contreras-Martinez,
L. Dootlittle,
J. Fuerst,
D. Gonnella,
A. Grassellino,
C. Grimm,
B. Hansen,
E. Harms,
B. Hartsell,
G. Hays,
J. Holzbauer,
S. Hoobler,
J. Kaluzny,
T. Khabiboulline,
M. Kucera
, et al. (21 additional authors not shown)
Abstract:
An 8-cavity, 1.3 GHz, LCLS-II-HE cryomodule was assembled and tested at Fermilab to verify performance before the start of production. Its cavities were processed with a novel nitrogen doping treatment to improve gradient performance. The cryomodule was tested with a modified protocol to process sporadic quenches, which were observed in LCLS-II production cryomodules and are attributed to multipac…
▽ More
An 8-cavity, 1.3 GHz, LCLS-II-HE cryomodule was assembled and tested at Fermilab to verify performance before the start of production. Its cavities were processed with a novel nitrogen doping treatment to improve gradient performance. The cryomodule was tested with a modified protocol to process sporadic quenches, which were observed in LCLS-II production cryomodules and are attributed to multipacting. Dedicated vertical test experiments support the attribution to multipacting. The verification cryomodule achieved an acceleration voltage of 200 MV in continuous wave mode, corresponding to an average accelerating gradient of 24.1 MV/m, significantly exceeding the specification of 173 MV. The average Q0 (3.0x10^10) also exceeded its specification (2.7x10^10). After processing, no field emission was observed up to the maximum gradient of each cavity. This paper reviews the cryomodule performance and discusses operational issues and mitigations implemented during the several month program.
△ Less
Submitted 27 October, 2021;
originally announced October 2021.
-
Field emission mitigation studies in LCLS-II cavities via in situ plasma processing
Authors:
Bianca Giaccone,
Martina Martinello,
Paolo Berrutti,
Oleksandr Melnychuk,
Dmitri A. Sergatskov,
Anna Grassellino,
Dan Gonnella,
Marc Ross,
Marc Doleans,
John F. Zasadzinski
Abstract:
Field emission is one of the factors that can limit the performance of superconducting radio frequency cavities. In order to reduce possible field emission in LCLS-II (Linac Coherent Light Source II), we are developing plasma processing for 1.3 GHz 9-cell cavities. Plasma processing can be applied in situ in the cryomodule to mitigate field emission related to hydrocarbon contamination present on…
▽ More
Field emission is one of the factors that can limit the performance of superconducting radio frequency cavities. In order to reduce possible field emission in LCLS-II (Linac Coherent Light Source II), we are developing plasma processing for 1.3 GHz 9-cell cavities. Plasma processing can be applied in situ in the cryomodule to mitigate field emission related to hydrocarbon contamination present on the cavity surface. In this paper, plasma cleaning was applied to single cell and 9-cell cavities, both clean and contaminated; the cavities were cold tested before and after plasma processing in order to compare their performance. It was proved that plasma cleaning does not negatively affect the nitrogen doping surface treatment; on the contrary, it preserves the high quality factor and quench field. Plasma processing was also applied to cavities with natural field emission or artificially contaminated. It was found that this technique successfully removes carbon-based contamination from the cavity iris and that it is able to remove field emission in a naturally field emitting cavity. Vacuum failure experiments were simulated on four cavities, and in some cases plasma processing was able to achieve an increase in performance.
△ Less
Submitted 5 October, 2020; v1 submitted 10 September, 2020;
originally announced September 2020.
-
Low RF power plasma ignition and detection for in-situ cleaning of 1.3 GHz 9-cell cavities
Authors:
P. Berrutti,
B. Giaccone,
M. Martinello,
A. Grassellino,
T. Khabiboulline,
M. Doleans,
S. Kim,
D. Gonnella,
G. Lanza,
M. Ross
Abstract:
Superconducting Radio Frequency (SRF) cavities performance preservation is crucial, from vertical test to accelerator operation. Field Emission (FE) is still one of the performance limiting factors to overcome and plasma cleaning has been proven successful by the Spallation Neutron Source (SNS), in cleaning field emitters and increasing the work function of Nb. A collaboration has been established…
▽ More
Superconducting Radio Frequency (SRF) cavities performance preservation is crucial, from vertical test to accelerator operation. Field Emission (FE) is still one of the performance limiting factors to overcome and plasma cleaning has been proven successful by the Spallation Neutron Source (SNS), in cleaning field emitters and increasing the work function of Nb. A collaboration has been established between Fermi National Accelerator Laboratory (FNAL), SLAC National Accelerator Laboratory and Oak Ridge National Laboratory (ORNL) with the purpose of applying plasma processing to the Linac Coherent Light Source-II (LCLS-II) cavities, in order to minimize and overcome field emission without affecting the high Q of nitrogen-doped cavities. The cleaning for LCLS-II will follow the same plasma composition adopted at SNS, which allows in-situ processing of cavities installed in cryomodules from hydrocarbon contaminants. A novel method for plasma ignition has been developed at FNAL: a plasma glow discharge is ignited using high order modes to overcome limitations imposed by the fundamental power coupler, allowing in-situ cleaning for cavities in cryomodule. The plasma can be easily ignited and tuned in each of the cavity cells using low RF power. A method for plasma detection has been developed as well, which allows the detection of the plasma location in the cavity without the need of cameras at both cavity ends. The presented method can be applied to other multi-cell cavity designs, even for accelerators where the coupling for the fundamental modes at room temperature is very weak.
△ Less
Submitted 8 February, 2019;
originally announced February 2019.
-
The Role of Magnetic Flux Expulsion to Reach Q0>3x10^10 in SRF Cryomodules
Authors:
S. Posen,
G. Wu,
E. Harms,
A. Grassellino,
O. S. Melnychuk,
D. A. Sergatskov,
N. Solyak,
A. Palczewski,
D. Gonnella,
T. Peterson
Abstract:
When a superconducting radiofrequency cavity is cooled through its critical temperature, ambient magnetic flux can become "frozen in" to the superconductor, resulting in degradation of the quality factor. This is especially problematic in applications where quality factor is a cost driver, such as in the CW linac for LCLS-II. Previously, it had been unknown how to prevent flux from being trapped d…
▽ More
When a superconducting radiofrequency cavity is cooled through its critical temperature, ambient magnetic flux can become "frozen in" to the superconductor, resulting in degradation of the quality factor. This is especially problematic in applications where quality factor is a cost driver, such as in the CW linac for LCLS-II. Previously, it had been unknown how to prevent flux from being trapped during cooldown in bulk niobium cavities, but recent R&D studies showed near-full flux expulsion can be achieved through high temperature heat treatment and cooling cavities through the superconducting transition with a spatial thermal gradient over the surface. In this paper, we describe the first accelerator implementation of these procedures, in cryomodules that are currently being produced for LCLS-II. We compare the performance of cavities under different conditions of heat treatment and thermal gradient during cooldown, showing a substantial improvement in performance when both are applied, enabling cryomodules to reach and, in many cases, exceed a Q0 of ~3x10^10.
△ Less
Submitted 10 December, 2018;
originally announced December 2018.
-
The Importance of the Electron Mean Free Path for Superconducting RF Cavities
Authors:
J. T. Maniscalco,
D. Gonnella,
M. Liepe
Abstract:
Impurity-doping is an exciting new technology in the field of SRF, producing cavities with record-high quality factor $Q_0$ and BCS surface resistance that decreases with increasing RF field. Recent theoretical work has offered a promising explanation for this anti-Q-slope, but the link between the decreasing surface resistance and the short mean free path of doped cavities has remained elusive. I…
▽ More
Impurity-doping is an exciting new technology in the field of SRF, producing cavities with record-high quality factor $Q_0$ and BCS surface resistance that decreases with increasing RF field. Recent theoretical work has offered a promising explanation for this anti-Q-slope, but the link between the decreasing surface resistance and the short mean free path of doped cavities has remained elusive. In this work we investigate this link, finding that the magnitude of this decrease varies directly with the mean free path: shorter mean free paths correspond with stronger anti-Q-slopes. We draw a theoretical connection between the mean free path and the overheating of the quasiparticles, which leads to the reduction of the anti-Q-slope towards the normal Q-slope of long-mean-free-path cavities. We also investigate the sensitivity of the residual resistance to trapped magnetic flux, a property which is greatly enhanced for doped cavities, and calculate an optimal doping regime for a given amount of trapped flux.
△ Less
Submitted 5 August, 2016; v1 submitted 5 July, 2016;
originally announced July 2016.
-
Sensitivity of Niobium Superconducting Cavities to Trapped Magnetic Flux Dissipation
Authors:
Dan Gonnella,
John Kaufman,
Matthias Liepe
Abstract:
Future particle accelerators such as the the SLAC ``Linac Coherent Light Source-II'' (LCLS-II) and the proposed Cornell Energy Recovery Linac (ERL) require hundreds of superconducting radio-frequency (SRF) cavities operating in continuous wave (CW) mode. In order to achieve economic feasibility of projects such as these, the cavities must achieve a very high intrinsic quality factor ($Q_0$) to kee…
▽ More
Future particle accelerators such as the the SLAC ``Linac Coherent Light Source-II'' (LCLS-II) and the proposed Cornell Energy Recovery Linac (ERL) require hundreds of superconducting radio-frequency (SRF) cavities operating in continuous wave (CW) mode. In order to achieve economic feasibility of projects such as these, the cavities must achieve a very high intrinsic quality factor ($Q_0$) to keep cryogenic losses within feasible limits. To reach these high $Q_0$'s in the case of LCLS-II, nitrogen-doping has been proposed as a cavity preparation technique. When dealing with $Q_0$'s greater than 1\e{10}, the effects of ambient magnetic field on $Q_0$ become significant. Here we show that the sensitivity to RF losses from trapped magnetic field in a cavity's walls is strongly dependent on the cavity preparation. Specifically, standard electropolished and 120$^\circ$C baked cavities show a residual resistance sensitivity to trapped magnetic flux of $\sim0.6$ and $\sim0.8$ n$Ω$/mG trapped, respectively, while nitrogen-doped cavities show a sensitivity of $\sim$ 1 to 5 n$Ω$/mG trapped. We show that this difference in sensitivities is directly related to the mean free path of the RF surface layer of the niobium: shorter mean free paths lead to less residual resistance sensitivity to trapped magnetic flux in the dirty limit ($\ell<<ξ_0$) while longer mean free paths lead to lower sensitivity in the clean limit ($\ell>>ξ_0$). These experimental results are also shown to have good agreement with recent theoretical predictions for pinned vortex lines oscillating in RF fields.
△ Less
Submitted 24 November, 2015; v1 submitted 14 September, 2015;
originally announced September 2015.
-
Thermocurrents and their Role in high Q Cavity Performance
Authors:
R. Eichhorn,
C. Daly,
F. Furuta,
A. Ganshyn,
D. Gonnella,
D. Hall,
V. Ho,
G. H. Hoffstaetter,
M. Liepe,
J. May-Mann,
T. O'Connell,
S. Posen,
P. Quigley,
J. Sears,
V. Veshcherevich
Abstract:
Over the past years it became evident that the quality factor of a superconducting cavity is not only determined by its surface preparation procedure, but is also influenced by the way the cavity is cooled down. Moreover, different data sets exists, some of them indicate that a slow cool-down through the critical temperature is favourable while other data states the exact opposite. Even so there w…
▽ More
Over the past years it became evident that the quality factor of a superconducting cavity is not only determined by its surface preparation procedure, but is also influenced by the way the cavity is cooled down. Moreover, different data sets exists, some of them indicate that a slow cool-down through the critical temperature is favourable while other data states the exact opposite. Even so there where speculations and some models about the role of thermo-currents and flux-pinning, the difference in behaviour remained a mystery. In this paper we will for the first time present a consistent theoretical model which we confirmed by data that describes the role of thermo-currents, driven by temperature gradients and material transitions. We will clearly show how they impact the quality factor of a cavity, discuss our findings, relate it to findings at other labs and develop mitigation strategies which especially addresses the issue of achieving high quality factors of so-called nitrogen doped cavities in horizontal test.
△ Less
Submitted 12 January, 2015; v1 submitted 19 November, 2014;
originally announced November 2014.
-
Nitrogen-Doped 9-Cell Cavity Performance in a Test Cryomodule for LCLS-II
Authors:
Dan Gonnella,
Ralf Eichhorn,
Fumio Furuta,
Mingqi Ge,
Daniel Hall,
Vivian Ho,
Georg Hoffstaetter,
Matthias Liepe,
Tim O'Connell,
Sam Posen,
Peter Quigley,
James Sears,
Vadim Veshcherevich,
Anna Grassellino,
Alexander Romanenko,
Dmitri Sergatskov
Abstract:
The superconducting RF linac for LCLS-II calls for 1.3 GHz 9-cell cavities with an average intrinsic quality factor Q0 of 2.7x10^10 at 2 K and 16 MV/m accelerating gradient. Two niobium 9-cell cavities, prepared with nitrogen-doping at Fermilab, were assembled into the Cornell Horizontal Test Cryomodule (HTC) to test cavity performance in a cryomodule that is very similar to a full LCLS-II cryomod…
▽ More
The superconducting RF linac for LCLS-II calls for 1.3 GHz 9-cell cavities with an average intrinsic quality factor Q0 of 2.7x10^10 at 2 K and 16 MV/m accelerating gradient. Two niobium 9-cell cavities, prepared with nitrogen-doping at Fermilab, were assembled into the Cornell Horizontal Test Cryomodule (HTC) to test cavity performance in a cryomodule that is very similar to a full LCLS-II cryomodule. The cavities met LCLS-II specifications with an average quench field of 17 MV/m and an average Q0 of 3x10^10. The sensitivity of the cavities' residual resistance to ambient magnetic field was determined to be 0.5 nOhm/mG during fast cool down. In two cool downs, a heater attached to one of the cavity beam tubes was used to induce large horizontal temperature gradients. Here we report on the results of these first tests of nitrogen-doped cavities in cryomodule, which provide critical information for the LCLS-II project.
△ Less
Submitted 13 November, 2014; v1 submitted 6 November, 2014;
originally announced November 2014.
-
On superconducting niobium accelerating cavities fired under N2-gas exposure
Authors:
Ralf Eichhorn,
Daniel Gonnella,
Georg Hoffstaetter,
Matthias Liepe,
Wolfgang Weingarten
Abstract:
The dependence of the Q-value on the RF field (Q-slope) is actively studied in various accelerator laboratories. Although remedies against this dependence have been found, the physical cause still remains obscure. A rather straightforward two-fluid model description of the Q-slope in the low and high field domains is presented with emphasis on the recently experimentally identified improvement of…
▽ More
The dependence of the Q-value on the RF field (Q-slope) is actively studied in various accelerator laboratories. Although remedies against this dependence have been found, the physical cause still remains obscure. A rather straightforward two-fluid model description of the Q-slope in the low and high field domains is presented with emphasis on the recently experimentally identified improvement of the Q-value by so-called "N-doping".
△ Less
Submitted 28 May, 2015; v1 submitted 11 July, 2014;
originally announced July 2014.