Few-electron highly charged muonic Ar atoms verified by electronic $K$ x rays
Authors:
T. Okumura,
T. Azuma,
D. A. Bennett,
W. B. Doriese,
M. S. Durkin,
J. W. Fowler,
J. D. Gard,
T. Hashimoto,
R. Hayakawa,
Y. Ichinohe,
P. Indelicato,
T. Isobe,
S. Kanda,
D. Kato,
M. Katsuragawa,
N. Kawamura,
Y. Kino,
N. Kominato,
Y. Miyake,
K. M. Morgan,
H. Noda,
G. C. O'Neil,
S. Okada,
K. Okutsu,
N. Paul
, et al. (18 additional authors not shown)
Abstract:
Electronic $K$ x rays emitted by muonic Ar atoms in the gas phase were observed using a superconducting transition-edge-sensor microcalorimeter. The high-precision energy spectra provided a clear signature of the presence of muonic atoms accompanied by a few electrons, which have never been observed before. One-, two-, and three-electron bound, i.e., H-like, He-like, and Li-like, muonic Ar atoms w…
▽ More
Electronic $K$ x rays emitted by muonic Ar atoms in the gas phase were observed using a superconducting transition-edge-sensor microcalorimeter. The high-precision energy spectra provided a clear signature of the presence of muonic atoms accompanied by a few electrons, which have never been observed before. One-, two-, and three-electron bound, i.e., H-like, He-like, and Li-like, muonic Ar atoms were identified from electronic $K$ x rays and hyper-satellite $K$ x rays. These $K$ x rays are emitted after the charge transfer process by the collisions with surrounding Ar atoms. With the aid of theoretical calculations, we confirmed that the peak positions are consistent with the x-ray energies from highly charged Cl ions, and the intensities reflecting deexcitation dynamics were successfully understood by taking into account the interaction between the muon and bound electrons.
△ Less
Submitted 10 July, 2024;
originally announced July 2024.
-
A tabletop x-ray tomography instrument for nanometer-scale imaging: demonstration of the 1,000-element transition-edge sensor subarray
Authors:
Paul Szypryt,
Nathan Nakamura,
Daniel T. Becker,
Douglas A. Bennett,
Amber L. Dagel,
W. Bertrand Doriese,
Joseph W. Fowler,
Johnathon D. Gard,
J. Zachariah Harris,
Gene C. Hilton,
Jozsef Imrek,
Edward S. Jimenez,
Kurt W. Larson,
Zachary H. Levine,
John A. B. Mates,
D. McArthur,
Luis Miaja-Avila,
Kelsey M. Morgan,
Galen C. O'Neil,
Nathan J. Ortiz,
Christine G. Pappas,
Daniel R. Schmidt,
Kyle R. Thompson,
Joel N. Ullom,
Leila Vale
, et al. (6 additional authors not shown)
Abstract:
We report on the 1,000-element transition-edge sensor (TES) x-ray spectrometer implementation of the TOMographic Circuit Analysis Tool (TOMCAT). TOMCAT combines a high spatial resolution scanning electron microscope (SEM) with a highly efficient and pixelated TES spectrometer to reconstruct three-dimensional maps of nanoscale integrated circuits (ICs). A 240-pixel prototype spectrometer was recent…
▽ More
We report on the 1,000-element transition-edge sensor (TES) x-ray spectrometer implementation of the TOMographic Circuit Analysis Tool (TOMCAT). TOMCAT combines a high spatial resolution scanning electron microscope (SEM) with a highly efficient and pixelated TES spectrometer to reconstruct three-dimensional maps of nanoscale integrated circuits (ICs). A 240-pixel prototype spectrometer was recently used to reconstruct ICs at the 130 nm technology node, but to increase imaging speed to more practical levels, the detector efficiency needs to be improved. For this reason, we are building a spectrometer that will eventually contain 3,000 TES microcalorimeters read out with microwave superconducting quantum interference device (SQUID) multiplexing, and we currently have commissioned a 1,000 TES subarray. This still represents a significant improvement from the 240-pixel system and allows us to begin characterizing the full spectrometer performance. Of the 992 maximimum available readout channels, we have yielded 818 devices, representing the largest number of TES x-ray microcalorimeters simultaneously read out to date. These microcalorimeters have been optimized for pulse speed rather than purely energy resolution, and we measure a FWHM energy resolution of 14 eV at the 8.0 keV Cu K$α$ line.
△ Less
Submitted 22 December, 2022;
originally announced December 2022.
-
Nanoscale Three-Dimensional Imaging of Integrated Circuits using a Scanning Electron Microscope and Transition-Edge Sensor Spectrometer
Authors:
Nathan Nakamura,
Paul Szypryt,
Amber L. Dagel,
Bradley K. Alpert,
Douglas A. Bennett,
W. Bertrand Doriese,
Malcolm Durkin,
Joseph W. Fowler,
Dylan T. Fox,
Johnathon D. Gard,
Ryan N. Goodner,
J. Zachariah Harris,
Gene C. Hilton,
Edward S. Jimenez,
Burke L. Kernen,
Kurt W. Larson,
Zachary H. Levine,
Daniel McArthur,
Kelsey M. Morgan,
Galen C. O'Neil,
Nathan J. Ortiz,
Christine G. Pappas,
Carl D. Reintsema,
Daniel R. Schmidt,
Peter A. Schultz
, et al. (8 additional authors not shown)
Abstract:
X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but is difficult to implement due to competing requirements on X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial res…
▽ More
X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but is difficult to implement due to competing requirements on X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while changing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot in a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with high signal-to-noise. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enable nanoscale, element-specific X-ray imaging in a compact footprint. The proof-of-concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in 6 layers of a Cu-SiO2 integrated circuit, and a path towards finer resolution and enhanced imaging capabilities is discussed.
△ Less
Submitted 4 March, 2024; v1 submitted 20 December, 2022;
originally announced December 2022.
-
Design of a 3000-pixel transition-edge sensor x-ray spectrometer for microcircuit tomography
Authors:
Paul Szypryt,
Douglas A. Bennett,
William J. Boone,
Amber L. Dagel,
Gabriella Dalton,
W. Bertrand Doriese,
Joseph W. Fowler,
Edward J. Garboczi,
Johnathon D. Gard,
Gene C. Hilton,
Jozsef Imrek,
Edward S. Jimenez,
Vincent Y. Kotsubo,
Kurt Larson,
Zachary H. Levine,
John A. B. Mates,
Daniel McArthur,
Kelsey M. Morgan,
Nathan Nakamura,
Galen C. O'Neil,
Nathan J. Ortiz,
Christine G. Pappas,
Carl D. Reintsema,
Daniel R. Schmidt,
Daniel S. Swetz
, et al. (6 additional authors not shown)
Abstract:
Feature sizes in integrated circuits have decreased substantially over time, and it has become increasingly difficult to three-dimensionally image these complex circuits after fabrication. This can be important for process development, defect analysis, and detection of unexpected structures in externally sourced chips, among other applications. Here, we report on a non-destructive, tabletop approa…
▽ More
Feature sizes in integrated circuits have decreased substantially over time, and it has become increasingly difficult to three-dimensionally image these complex circuits after fabrication. This can be important for process development, defect analysis, and detection of unexpected structures in externally sourced chips, among other applications. Here, we report on a non-destructive, tabletop approach that addresses this imaging problem through x-ray tomography, which we uniquely realize with an instrument that combines a scanning electron microscope (SEM) with a transition-edge sensor (TES) x-ray spectrometer. Our approach uses the highly focused SEM electron beam to generate a small x-ray generation region in a carefully designed target layer that is placed over the sample being tested. With the high collection efficiency and resolving power of a TES spectrometer, we can isolate x-rays generated in the target from background and trace their paths through regions of interest in the sample layers, providing information about the various materials along the x-ray paths through their attenuation functions. We have recently demonstrated our approach using a 240 Mo/Cu bilayer TES prototype instrument on a simplified test sample containing features with sizes of $\sim$1 $μ$m. Currently, we are designing and building a 3000 Mo/Au bilayer TES spectrometer upgrade, which is expected to improve the imaging speed by factor of up to 60 through a combination of increased detector number and detector speed.
△ Less
Submitted 14 December, 2022;
originally announced December 2022.
-
Absolute Energy Measurements with Superconducting Transition-Edge Sensors for Muonic X-ray Spectroscopy at 44 keV
Authors:
Daikang Yan,
Joel C. Weber,
Tejas Guruswamy,
Kelsey M. Morgan,
Galen C. O'Neil,
Abigail L. Wessels,
Douglas A. Bennett,
Christine G. Pappas,
John A. Mates,
Johnathon D. Gard,
Daniel T. Becker,
Joseph W. Fowler,
Daniel S. Swetz,
Daniel R. Schmidt,
Joel N. Ullom,
Takuma Okumura,
Tadaaki Isobe,
Toshiyuki Azuma,
Shinji Okada,
Shinya Yamada,
Tadashi Hashimoto,
Orlando Quaranta,
Antonino Miceli,
Lisa M. Gades,
Umeshkumar M. Patel
, et al. (3 additional authors not shown)
Abstract:
Superconducting transition-edge sensor (TES) microcalorimeters have great utility in x-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this work, we develop hard x-ray TESs to measure the absolute energies of muonic-argon ($μ$-Ar) transition lines around 44 keV and 20 keV. TESs with sidecar absorbers…
▽ More
Superconducting transition-edge sensor (TES) microcalorimeters have great utility in x-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this work, we develop hard x-ray TESs to measure the absolute energies of muonic-argon ($μ$-Ar) transition lines around 44 keV and 20 keV. TESs with sidecar absorbers of different heat capacities were fabricated and characterized for their energy resolution and calibration uncertainty. We achieved ~ 1 eV absolute energy measurement accuracy at 44 keV, and < 12 eV energy resolution at 17.5 keV.
△ Less
Submitted 21 July, 2022;
originally announced July 2022.
-
Quantification of 242Pu with a Microcalorimeter Gamma Spectrometer
Authors:
David J. Mercer,
Ryan Winkler,
Katrina E. Koehler,
Daniel T. Becker,
Douglas A. Bennett,
Matthew H. Carpenter,
Mark P. Croce,
Krystal I. de Castro,
Eric A. Feissle,
Joseph W. Fowler,
Johnathon D. Gard,
John A. B. Mates,
Daniel G. McNeel,
Nathan J. Ortiz,
Daniel Schmidt,
Katherine A. Schreiber,
Daniel S. Swetz,
Joel N. Ullom,
Leila R. Vale,
Sophie L. Weidenbenner,
Abigail L. Wessels
Abstract:
We report measurements of the 103-keV and 159-keV gamma ray signatures of 242Pu using microcalorimetry. This is the first observation of these gamma rays in a non-destructive measurement of an unprepared sample, and so represents an important advance in nuclear material accountancy. The measurement campaign also serves as the first demonstration of a field campaign with a portable microcalorimeter…
▽ More
We report measurements of the 103-keV and 159-keV gamma ray signatures of 242Pu using microcalorimetry. This is the first observation of these gamma rays in a non-destructive measurement of an unprepared sample, and so represents an important advance in nuclear material accountancy. The measurement campaign also serves as the first demonstration of a field campaign with a portable microcalorimeter gamma-ray spectrometer. For the 103-keV gamma ray we report an improved centroid energy and emission probability.
△ Less
Submitted 8 July, 2022; v1 submitted 6 February, 2022;
originally announced February 2022.
-
New Experimentally Observable Gamma-ray Emissions from 241Am Nuclear Decay
Authors:
Katrina E. Koehler,
Michael D. Yoho,
Matthew H. Carpenter,
Mark P. Croce,
David J. Mercer,
Chandler M. Smith,
Aidan D. Tollefson,
Duc T. Vo,
Michael A. Famiano,
Caroline D. Nesaraja,
Daniel T. Becker,
Johnathon D. Gard,
Abigail L. Wessels,
Douglas A. Bennett,
J. A. B. Mates,
Nathan J. Ortiz,
Daniel R. Schmidt,
Joel N. Ullom,
Leila R. Vale
Abstract:
With the high resolution of microcalorimeter detectors, previously unresolvable gamma-ray lines are now clearly resolvable. A careful measurement of Am-241 decay with a large array of gamma-ray microcalorimeters has revealed never before seen or predicted gamma lines at 207.72 +/- 0.02 keV and 208.21 +/- 0.01 keV. These results were made possible by new microwave-multiplexing readout to increase t…
▽ More
With the high resolution of microcalorimeter detectors, previously unresolvable gamma-ray lines are now clearly resolvable. A careful measurement of Am-241 decay with a large array of gamma-ray microcalorimeters has revealed never before seen or predicted gamma lines at 207.72 +/- 0.02 keV and 208.21 +/- 0.01 keV. These results were made possible by new microwave-multiplexing readout to increase the array size and improved analysis algorithms to eliminate spectral artifacts. We suggest nuclear levels from which these gamma-rays might originate and calculate branching ratios for these transitions from measurements of both mixed Pu-Am standards and a pure Am-241 source. These results have implications for nuclear material safeguards and accounting, particularly for microcalorimeter gamma spectrometers, which are now being adopted in nuclear safeguards analytical laboratories.
△ Less
Submitted 19 August, 2024; v1 submitted 29 March, 2021;
originally announced March 2021.
-
Progress in the development of TES microcalorimeter detectors suitable for neutrino mass measurement
Authors:
A. Giachero,
B. Alpert,
D. T. Becker,
D. A. Bennett,
M. Borghesi,
M. De Gerone,
M. Faverzani,
M. Fedkevych,
E. Ferri,
G. Gallucci,
J. D. Gard,
F. Gatti,
G. C. Hilton,
J. A. B. Mates,
A. Nucciotti,
G. Pessina,
A. Puiu,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
L. R. Vale
Abstract:
The HOLMES experiment will perform a precise calorimetric measurement of the end point of the Electron Capture (EC) decay spectrum of 163Ho in order to extract information on neutrino mass with a sensitivity below 2 eV. In its final configuration, HOLMES will deploy 1000 detectors of low-temperature microcalorimeters with implanted 163Ho nuclei. The baseline sensors for HOLMES are Mo/Cu TESs (Tran…
▽ More
The HOLMES experiment will perform a precise calorimetric measurement of the end point of the Electron Capture (EC) decay spectrum of 163Ho in order to extract information on neutrino mass with a sensitivity below 2 eV. In its final configuration, HOLMES will deploy 1000 detectors of low-temperature microcalorimeters with implanted 163Ho nuclei. The baseline sensors for HOLMES are Mo/Cu TESs (Transition Edge Sensors) on SiNx membrane with gold absorbers. Considering the large number of pixels and an event rate of about 300 Hz/pixel, a large multiplexing factor and a large bandwidth are needed. To fulfill this requirement, HOLMES will exploit recent advances in microwave multiplexing. In this contribution, we present the status of the activities in development, the performances of the developed microwave-multiplexed readout system, and the results obtained with the detectors specifically designed for HOLMES in terms of noise, time, and energy resolutions
△ Less
Submitted 7 January, 2021;
originally announced January 2021.
-
A Microwave SQUID Multiplexer Optimized for Bolometric Applications
Authors:
B. Dober,
Z. Ahmed,
K. Arnold,
D. T. Becker,
D. A. Bennett,
J. A. Connors,
A. Cukierman,
J. M. D'Ewart,
S. M. Duff,
J. E. Dusatko,
J. C. Frisch,
J. D. Gard,
S. W. Henderson,
R. Herbst,
G. C. Hilton,
J. Hubmayr,
Y. Li,
J. A. B. Mates,
H. McCarrick,
C. D Reintsema,
M. Silva-Feaver,
L. Ruckman,
J. N. Ullom,
L. R. Vale,
D. D. Van Winkle
, et al. (5 additional authors not shown)
Abstract:
A microwave SQUID multiplexer ($μ$MUX) has been optimized for coupling to large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design in a 1820-channel multiplexer configuration for the 4-8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4…
▽ More
A microwave SQUID multiplexer ($μ$MUX) has been optimized for coupling to large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design in a 1820-channel multiplexer configuration for the 4-8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4-5 GHz. The median white-noise level is 45 pA/$\sqrt{\textrm{Hz}}$, evaluated at 2 Hz, with a 1/f knee $\leq$ 20 mHz after common-mode subtraction. The white-noise level decreases the sensitivity of a TES bolometer optimized for detection of the cosmic microwave background at 150 GHz by only 3%. The measured crosstalk between any channel pair is $\leq$ 0.3%.
△ Less
Submitted 19 January, 2021; v1 submitted 15 October, 2020;
originally announced October 2020.
-
Improved Plutonium and Americium Photon Branching Ratios from Microcalorimeter Gamma Spectroscopy
Authors:
Michael D. Yoho,
Katrina E. Koehler,
Daniel T. Becker,
Douglas A. Bennett,
Matthew H. Carpenter,
Mark P. Croce,
Johnathon D. Gard,
J. A. Ben Mates,
David J. Mercer,
Nathan J. Ortiz,
Daniel R. Schmidt,
Chandler M. Smith,
Daniel S. Swetz,
Aidan D. Tollefson,
Joel N. Ullom,
Leila R. Vale,
Abigail L. Wessels,
Duc T. Vo
Abstract:
Photon branching ratios are critical input data for activities such as nuclear materials protection and accounting because they allow material compositions to be extracted from measurements of gamma-ray intensities. Uncertainties in these branching ratios are often a limiting source of uncertainty in composition determination. Here, we use high statistics, high resolution (~60-70eV full-width-at-h…
▽ More
Photon branching ratios are critical input data for activities such as nuclear materials protection and accounting because they allow material compositions to be extracted from measurements of gamma-ray intensities. Uncertainties in these branching ratios are often a limiting source of uncertainty in composition determination. Here, we use high statistics, high resolution (~60-70eV full-width-at-half-maximum at 100 keV) gamma-ray spectra acquired using microcalorimeter sensors to substantially reduce the uncertainties for 11 plutonium (238Pu,239Pu,241Pu) and 241Am branching ratios important for material control and accountability and nuclear forensics in the energy range of 125 keV to 208 keV. We show a reduction in uncertainty of over a factor of three for one branching ratio and a factor of 2{3 for four branching ratios.
△ Less
Submitted 22 June, 2020; v1 submitted 20 May, 2020;
originally announced May 2020.
-
A Transition-edge Sensor-based X-ray Spectrometer for the Study of Highly Charged Ions at the National Institute of Standards and Technology Electron Beam Ion Trap
Authors:
P. Szypryt,
G. C. O'Neil,
E. Takacs,
J. N. Tan,
S. W. Buechele,
A. S. Naing,
D. A. Bennett,
W. B. Doriese,
M. Durkin,
J. W. Fowler,
J. D. Gard,
G. C. Hilton,
K. M. Morgan,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
Yu. Ralchenko
Abstract:
We report on the design, commissioning, and initial measurements of a Transition-edge Sensor (TES) x-ray spectrometer for the Electron Beam Ion Trap (EBIT) at the National Institute of Standards and Technology (NIST). Over the past few decades, the NIST EBIT has produced numerous studies of highly charged ions in diverse fields such as atomic physics, plasma spectroscopy, and laboratory astrophysi…
▽ More
We report on the design, commissioning, and initial measurements of a Transition-edge Sensor (TES) x-ray spectrometer for the Electron Beam Ion Trap (EBIT) at the National Institute of Standards and Technology (NIST). Over the past few decades, the NIST EBIT has produced numerous studies of highly charged ions in diverse fields such as atomic physics, plasma spectroscopy, and laboratory astrophysics. The newly commissioned NIST EBIT TES Spectrometer (NETS) improves the measurement capabilities of the EBIT through a combination of high x-ray collection efficiency and resolving power. NETS utilizes 192 individual TES x-ray microcalorimeters (166/192 yield) to improve upon the collection area by a factor of ~30 over the 4-pixel neutron transmutation doped germanium-based microcalorimeter spectrometer previously used at the NIST EBIT. The NETS microcalorimeters are optimized for the x-ray energies from roughly 500 eV to 8,000 eV and achieve an energy resolution of 3.7 eV to 5.0 eV over this range, a more modest (<2X) improvement over the previous microcalorimeters. Beyond this energy range NETS can operate with various trade-offs, the most significant of which are reduced efficiency at lower energies and being limited to a subset of the pixels at higher energies. As an initial demonstration of the capabilities of NETS, we measured transitions in He-like and H-like O, Ne, and Ar as well as Ni-like W. We detail the energy calibration and data analysis techniques used to transform detector counts into x-ray spectra, a process that will be the basis for analyzing future data.
△ Less
Submitted 11 May, 2020;
originally announced May 2020.
-
On low-energy tail distortions in the detector responsefunction of x-ray microcalorimeter spectrometers
Authors:
G. C. O'Neil,
P. Szypryt,
E. Takacs,
J. N. Tan,
S. W. Buechele,
A. S. Naing,
Y. I. Joe,
D. Swetz,
D. R. Schmidt,
W. B. Doriese,
J. D. Gard,
C. D. Reintsema,
J. N. Ullom,
J. S. Villarrubia,
Yu. Ralchenko
Abstract:
We use narrow spectral lines from the x-ray spectra of various highlycharged ions to measure low-energy tail-like deviations from a Gaussian responsefunction in a microcalorimter x-ray spectrometer with Au absorbers at energiesfrom 650 eV to 3320 eV. We review the literature on low energy tails in othermicrocalorimter x-ray spectrometers and present a model that explains all thereviewed tail fract…
▽ More
We use narrow spectral lines from the x-ray spectra of various highlycharged ions to measure low-energy tail-like deviations from a Gaussian responsefunction in a microcalorimter x-ray spectrometer with Au absorbers at energiesfrom 650 eV to 3320 eV. We review the literature on low energy tails in othermicrocalorimter x-ray spectrometers and present a model that explains all thereviewed tail fraction measurements. In this model a low energy tail arises fromthe combination of electron escape and energy trapping associated with Bi x-rayabsorbers.
△ Less
Submitted 11 May, 2020;
originally announced May 2020.
-
Working principle and demonstrator of microwave-multiplexing for the HOLMES experiment microcalorimeters
Authors:
D. T. Becker,
D. A. Bennett,
M. Biasotti,
M. Borghesi,
V. Ceriale,
M. De Gerone,
M. Faverzani,
E. Ferri,
J. W. Fowler,
G. Gallucci,
J. D. Gard,
A. Giachero,
J. P. Hays-Wehle,
G. C. Hilton,
J. A. B Mates,
A. Nucciotti,
A. Orlando,
G. Pessina,
A. Puiu,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
L. R Vale
Abstract:
The determination of the neutrino mass is an open issue in modern particle physics and astrophysics. The direct mass measurement is the only theory-unrelated experimental tool capable to probe such quantity. The HOLMES experiment aims to measure the end-point energy of the electron capture (EC) decay of $^{163}$Ho with a statistical sensitivity on the neutrino mass as low as $\sim 1$ eV/c$^2$. In…
▽ More
The determination of the neutrino mass is an open issue in modern particle physics and astrophysics. The direct mass measurement is the only theory-unrelated experimental tool capable to probe such quantity. The HOLMES experiment aims to measure the end-point energy of the electron capture (EC) decay of $^{163}$Ho with a statistical sensitivity on the neutrino mass as low as $\sim 1$ eV/c$^2$. In order to acquire the large needed statistics, by keeping the pile-up contribution as low as possible, 1024 transition edge sensors (TESs) with high energy and time resolutions will be employed. Microcalorimeter and bolometer arrays based on transition edge sensor with thousands of pixels are under development for several space-based and ground-based applications, including astrophysics, nuclear and particle physics, and materials science. The common necessary challenge is to develop pratical multiplexing techniques in order to simplify the cryogenics and readout systems. Despite the various multiplexing variants which are being developed have been successful, new approaches are needed to enable scaling to larger pixel counts and faster sensors, as requested for HOLMES, reducing also the cost and complexity of readout. A very novel technique that meets all of these requirements is based on superconducting microwave resonators coupled to radio-frequency Superconducting Quantum Interference Devices, in which the the changes in the TES input current is tranduced to a change in phase of a microwave signal. In this work we introduce the basics of this technique, the design and development of the first two-channel read out system and its performances with the first TES detectors specifically designed for HOLMES. In the last part we explain how to extend this approach scaling to 1024 pixels.
△ Less
Submitted 11 October, 2019;
originally announced October 2019.
-
A Model for Excess Johnson Noise in Superconducting Transition-edge Sensors
Authors:
Abigail Wessels,
Kelsey Morgan,
Daniel T. Becker,
Johnathon D. Gard,
Gene C. Hilton,
John A. B. Mates,
Carl D. Reintsema,
Daniel R. Schmidt,
Daniel S. Swetz,
Joel N. Ullom,
Leila R. Vale,
Douglas A. Bennett
Abstract:
Transition-Edge Sensors (TESs) are two-dimensional superconducting films used to detect energy or power. TESs are voltage biased in the resistive transition where the film resistance is both finite and a strong function of temperature. Electrical noise is observed in TESs that exceeds the predictions of existing noise theories. In this manuscript, we describe a model for the unexplained excess noi…
▽ More
Transition-Edge Sensors (TESs) are two-dimensional superconducting films used to detect energy or power. TESs are voltage biased in the resistive transition where the film resistance is both finite and a strong function of temperature. Electrical noise is observed in TESs that exceeds the predictions of existing noise theories. In this manuscript, we describe a model for the unexplained excess noise based on the dynamic resistance of the TES and noise mixed down from frequencies around the Josephson oscillations. We derive an expression for the power spectral density of this noise and show that its predictions match measured data.
△ Less
Submitted 25 July, 2019;
originally announced July 2019.
-
Mitigating the effects of charged particle strikes on TES arrays for exotic atom X-ray experiments
Authors:
H. Tatsuno,
D. A. Bennett,
W. B. Doriese,
M. Durkin,
J. W. Fowler,
J. D. Gard,
T. Hashimoto,
R. Hayakawa,
T. Hayashi,
G. C. Hilton,
Y. Ichinohe,
H. Noda,
G. C. O'Neil,
S. Okada,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
S. Yamada
Abstract:
Exotic atom experiments place transition-edge-sensor (TES) microcalorimeter arrays in a high-energy charged particle rich environment. When a high-energy charged particle passes through the silicon substrate of a TES array, a large amount of energy is deposited and small pulses are generated across multiple pixels in the TES array due to thermal crosstalk. We have developed analysis techniques to…
▽ More
Exotic atom experiments place transition-edge-sensor (TES) microcalorimeter arrays in a high-energy charged particle rich environment. When a high-energy charged particle passes through the silicon substrate of a TES array, a large amount of energy is deposited and small pulses are generated across multiple pixels in the TES array due to thermal crosstalk. We have developed analysis techniques to assess and reduce the effects of charged particle events on exotic atom X-ray measurements. Using this technique, the high-energy and low-energy components of the X-ray peaks due to pileup are eliminated, improving the energy resolution from 6.6 eV to 5.7 eV at 6.9 keV.
△ Less
Submitted 20 May, 2020; v1 submitted 14 July, 2019;
originally announced July 2019.
-
Highly-multiplexed microwave SQUID readout using the SLAC Microresonator Radio Frequency (SMuRF) Electronics for Future CMB and Sub-millimeter Surveys
Authors:
Shawn W. Henderson,
Zeeshan Ahmed,
Jason Austermann,
Daniel Becker,
Douglas A. Bennett,
David Brown,
Saptarshi Chaudhuri,
Hsiao-Mei Sherry Cho,
John M. D'Ewart,
Bradley Dober,
Shannon M. Duff,
John E. Dusatko,
Sofia Fatigoni,
Josef C. Frisch,
Jonathon D. Gard,
Mark Halpern,
Gene C. Hilton,
Johannes Hubmayr,
Kent D. Irwin,
Ethan D. Karpel,
Sarah S. Kernasovskiy,
Stephen E. Kuenstner,
Chao-Lin Kuo,
Dale Li,
John A. B. Mates
, et al. (7 additional authors not shown)
Abstract:
The next generation of cryogenic CMB and submillimeter cameras under development require densely instrumented sensor arrays to meet their science goals. The readout of large numbers ($\sim$10,000--100,000 per camera) of sub-Kelvin sensors, for instance as proposed for the CMB-S4 experiment, will require substantial improvements in cold and warm readout techniques. To reduce the readout cost per se…
▽ More
The next generation of cryogenic CMB and submillimeter cameras under development require densely instrumented sensor arrays to meet their science goals. The readout of large numbers ($\sim$10,000--100,000 per camera) of sub-Kelvin sensors, for instance as proposed for the CMB-S4 experiment, will require substantial improvements in cold and warm readout techniques. To reduce the readout cost per sensor and integration complexity, efforts are presently focused on achieving higher multiplexing density while maintaining readout noise subdominant to intrinsic detector noise. Highly-multiplexed cold readout technologies in active development include Microwave Kinetic Inductance Sensors (MKIDs) and microwave rf-SQUIDs. Both exploit the high quality factors of superconducting microwave resonators to densely channelize sub-Kelvin sensors into the bandwidth of a microwave transmission line. We present advancements in the development of a new warm readout system for microwave SQUID multiplexing, the SLAC Superconducting Microresonator RF electronics, or SMuRF. The SMuRF system is unique in its ability to track each tone, minimizing the total RF power required to read out each resonator, thereby significantly reducing the linearity requirements on the cold and warm readout. Here, we present measurements of the readout noise and linearity of the first full SMuRF system, including a demonstration of closed-loop tone tracking on a 528 channel cryogenic microwave SQUID multiplexer. SMuRF is being explored as a potential readout solution for several future CMB projects including Simons Observatory, BICEP Array, CCAT-prime, Ali-CPT, and CMB-S4. Parallel development of the platform is underway to adapt SMuRF to read out both MKID and fast X-ray TES calorimeter arrays.
△ Less
Submitted 11 September, 2018;
originally announced September 2018.
-
Microwave SQUID Multiplexer demonstration for Cosmic Microwave Background Imagers
Authors:
B. Dober,
D. T. Becker,
D. A. Bennett,
S. A. Bryan,
S. M. Duff,
J. D. Gard,
J. P. Hays-Wehle,
G. C. Hilton,
J. Hubmayr,
J. A. B. Mates,
C. D. Reintsema,
L. R. Vale,
J. N. Ullom
Abstract:
Key performance characteristics are demonstrated for the microwave SQUID multiplexer ($μ$MUX) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic microwave background (CMB) observations. In a 64-channel demonstration, we show that the $μ$MUX produces a white, input referred current noise level of 29~pA$/\sqrt{\mathrm{Hz}}$ at -77~dB microwave probe tone power, wh…
▽ More
Key performance characteristics are demonstrated for the microwave SQUID multiplexer ($μ$MUX) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic microwave background (CMB) observations. In a 64-channel demonstration, we show that the $μ$MUX produces a white, input referred current noise level of 29~pA$/\sqrt{\mathrm{Hz}}$ at -77~dB microwave probe tone power, which is well below expected fundamental detector and photon noise sources for a ground-based CMB-optimized bolometer. Operated with negligible photon loading, we measure 98~pA$/\sqrt{\mathrm{Hz}}$ in the TES-coupled channels biased at 65% of the sensor normal resistance. This noise level is consistent with that predicted from bolometer thermal fluctuation (i.e., phonon) noise. Furthermore, the power spectral density exhibits a white spectrum at low frequencies ($\sim$~100~mHz), which enables CMB mapping on large angular scales that constrain the physics of inflation. Additionally, we report cross-talk measurements that indicate a level below 0.3%, which is less than the level of cross-talk from multiplexed readout systems in deployed CMB imagers. These measurements demonstrate the $μ$MUX as a viable readout technique for future CMB imaging instruments.
△ Less
Submitted 15 December, 2017; v1 submitted 11 October, 2017;
originally announced October 2017.
-
L-Edge Spectroscopy of Dilute, Radiation-Sensitive Systems Using a Transition-Edge-Sensor Array
Authors:
Charles J. Titus,
Michael L. Baker,
Sang Jun Lee,
Hsiao-mei Cho,
William B. Doriese,
Joseph W. Fowler,
Kelly Gaffney,
Johnathon D. Gard,
Gene C. Hilton,
Chris Kenney,
Jason Knight,
Dale Li,
Ron Marks,
Michael P. Minitti,
Kelsey M. Morgan,
Galen C. O'Neil,
Carl D. Reintsema,
Daniel R. Schmidt,
Dimosthenis Sokaras,
Daniel S. Swetz,
Joel N. Ullom,
Tsu-Chien Weng,
Christopher Williams,
Betty A. Young,
Kent D. Irwin
, et al. (2 additional authors not shown)
Abstract:
We present X-ray absorption spectroscopy and resonant inelastic X-ray scattering (RIXS) measurements on the iron L-edge of 0.5 mM aqueous ferricyanide. These measurements demonstrate the ability of high-throughput transition-edge-sensor (TES) spectrometers to access the rich soft X-ray (100-2000eV) spectroscopy regime for dilute and radiation-sensitive samples. Our low-concentration data are in ag…
▽ More
We present X-ray absorption spectroscopy and resonant inelastic X-ray scattering (RIXS) measurements on the iron L-edge of 0.5 mM aqueous ferricyanide. These measurements demonstrate the ability of high-throughput transition-edge-sensor (TES) spectrometers to access the rich soft X-ray (100-2000eV) spectroscopy regime for dilute and radiation-sensitive samples. Our low-concentration data are in agreement with high-concentration measurements recorded by conventional grating-based spectrometers. These results show that soft X-ray RIXS spectroscopy acquired by high-throughput TES spectrometers can be used to study the local electronic structure of dilute metal-centered complexes relevant to biology, chemistry and catalysis. In particular, TES spectrometers have a unique ability to characterize frozen solutions of radiation- and temperature-sensitive samples.
△ Less
Submitted 18 August, 2017; v1 submitted 29 June, 2017;
originally announced June 2017.
-
A Reassessment of Absolute Energies of the X-ray L Lines of Lanthanide Metals
Authors:
J. W. Fowler,
B. K. Alpert,
D. A. Bennett,
W. B. Doriese,
J. D. Gard,
G. C. Hilton,
L. T. Hudson,
Y. -I. Joe,
K. M. Morgan,
G. C. O'Neil,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
C. I. Szabo,
J. N. Ullom.
Abstract:
We introduce a new technique for determining x-ray fluorescence line energies and widths, and we present measurements made with this technique of 22 x-ray L lines from lanthanide-series elements. The technique uses arrays of transition-edge sensors, microcalorimeters with high energy-resolving power that simultaneously observe both calibrated x-ray standards and the x-ray emission lines under stud…
▽ More
We introduce a new technique for determining x-ray fluorescence line energies and widths, and we present measurements made with this technique of 22 x-ray L lines from lanthanide-series elements. The technique uses arrays of transition-edge sensors, microcalorimeters with high energy-resolving power that simultaneously observe both calibrated x-ray standards and the x-ray emission lines under study. The uncertainty in absolute line energies is generally less than 0.4 eV in the energy range of 4.5 keV to 7.5 keV. Of the seventeen line energies of neodymium, samarium, and holmium, thirteen are found to be consistent with the available x-ray reference data measured after 1990; only two of the four lines for which reference data predate 1980, however, are consistent with our results. Five lines of terbium are measured with uncertainties that improve on those of existing data by factors of two or more. These results eliminate a significant discrepancy between measured and calculated x-ray line energies for the terbium Ll line (5.551 keV). The line widths are also measured, with uncertainties of 0.6 eV or less on the full-width at half-maximum in most cases. These measurements were made with an array of approximately one hundred superconducting x- ray microcalorimeters, each sensitive to an energy band from 1 keV to 8 keV. No energy-dispersive spectrometer has previously been used for absolute-energy estimation at this level of accuracy. Future spectrometers, with superior linearity and energy resolution, will allow us to improve on these results and expand the measurements to more elements and a wider range of line energies.
△ Less
Submitted 10 May, 2017; v1 submitted 1 February, 2017;
originally announced February 2017.
-
Development of microwave-multiplexed superconductive detectors for the HOLMES experiment
Authors:
A. Giachero,
D. Becker,
D. A. Bennett,
M. Faverzani,
E. Ferri,
J. W. Fowler,
J. D. Gard,
J. P. Hays-Wehle,
G. C. Hilton,
M. Maino,
J. A. B Mates,
A. Puiu,
A. Nucciotti,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
L. R Vale
Abstract:
In recent years, the progress on low temperature detector technologies has allowed design of large scale experiments aiming at pushing down the sensitivity on the neutrino mass below 1\,eV. Even with outstanding performances in both energy ($\sim$eV on keV) and time resolution ($\sim 1\,μ$s) on the single channel, a large number of detectors working in parallel is required to reach a sub-eV sensit…
▽ More
In recent years, the progress on low temperature detector technologies has allowed design of large scale experiments aiming at pushing down the sensitivity on the neutrino mass below 1\,eV. Even with outstanding performances in both energy ($\sim$eV on keV) and time resolution ($\sim 1\,μ$s) on the single channel, a large number of detectors working in parallel is required to reach a sub-eV sensitivity. HOLMES is a new experiment to directly measure the neutrino mass with a sensitivity as low as 2\,eV. HOLMES will perform a calorimetric measurement of the energy released in the electron capture (EC) decay of 163Ho. In its final configuration, HOLMES will deploy 1000 detectors of low temperature microcalorimeters with implanted 163Ho nuclei. The baseline sensors for HOLMES are Mo/Cu TESs (Transition Edge Sensors) on SiN\textsubscript{x} membrane with gold absorbers. The readout is based on the use of rf-SQUIDs as input devices with flux ramp modulation for linearization purposes; the rf-SQUID is then coupled to a superconducting lambda/4-wave resonator in the GHz range, and the modulated signal is finally read out using the homodyne technique. The TES detectors have been designed with the aim of achieving an energy resolution of a few eV at the spectrum endpoint and a time resolution of a few micro-seconds, in order to minimize pile-up artifacts.
△ Less
Submitted 18 January, 2016; v1 submitted 15 January, 2016;
originally announced January 2016.