-
A Large Ungated TPC with GEM Amplification
Authors:
M. Berger,
M. Ball,
L. Fabbietti,
B. Ketzer,
R. Arora,
R. Beck,
F. Böhmer,
J. -C. Chen,
F. Cusanno,
S. Dørheim,
J. Hehner,
N. Herrmann,
C. Höppner,
D. Kaiser,
M. Kis,
V. Kleipa,
I. Konorov,
J. Kunkel,
N. Kurz,
Y. Leifels,
P. Müllner,
R. Münzer,
S. Neubert,
J. Rauch,
C. J. Schmidt
, et al. (6 additional authors not shown)
Abstract:
A Time Projection Chamber (TPC) is an ideal device for the detection of charged particle tracks in a large volume covering a solid angle of almost $4π$. The high density of hits on a given particle track facilitates the task of pattern recognition in a high-occupancy environment and in addition provides particle identification by measuring the specific energy loss for each track. For these reasons…
▽ More
A Time Projection Chamber (TPC) is an ideal device for the detection of charged particle tracks in a large volume covering a solid angle of almost $4π$. The high density of hits on a given particle track facilitates the task of pattern recognition in a high-occupancy environment and in addition provides particle identification by measuring the specific energy loss for each track. For these reasons, TPCs with Multiwire Proportional Chamber (MWPC) amplification have been and are widely used in experiments recording heavy-ion collisions. A significant drawback, however, is the large dead time of the order of 1 ms per event generated by the use of a gating grid, which is mandatory to prevent ions created in the amplification region from drifting back into the drift volume, where they would severely distort the drift path of subsequent tracks. For experiments with higher event rates this concept of a conventional TPC operating with a triggered gating grid can therefore not be applied without a significant loss of data. A continuous readout of the signals is the more appropriate way of operation. This, however, constitutes a change of paradigm with considerable challenges to be met concerning the amplification region, the design and bandwidth of the readout electronics, and the data handling. A mandatory prerequisite for such an operation is a sufficiently good suppression of the ion backflow from the avalanche region, which otherwise limits the tracking and particle identification capabilities of such a detector. Gas Electron Multipliers (GEM) are a promising candidate to combine excellent spatial resolution with an intrinsic suppression of ions. In this paper we describe the design, construction and the commissioning of a large TPC with GEM amplification and without gating grid (GEM-TPC).
△ Less
Submitted 16 February, 2017;
originally announced February 2017.
-
Space-Charge Effects in an Ungated GEM-based TPC
Authors:
F. V. Böhmer,
M. Ball,
S. Dørheim,
C. Höppner,
B. Ketzer,
I. Konorov,
S. Neubert,
S. Paul,
J. Rauch,
M. Vandenbroucke
Abstract:
A fundamental limit to the application of Time Projection Chambers (TPCs) in high-rate experiments is the accumulation of slowly drifting ions in the active gas volume, which compromises the homogeneity of the drift field and hence the detector resolution. Conventionally, this problem is overcome by the use of ion-gating structures. This method, however, introduces large dead times and restricts t…
▽ More
A fundamental limit to the application of Time Projection Chambers (TPCs) in high-rate experiments is the accumulation of slowly drifting ions in the active gas volume, which compromises the homogeneity of the drift field and hence the detector resolution. Conventionally, this problem is overcome by the use of ion-gating structures. This method, however, introduces large dead times and restricts trigger rates to a few hundred per second. The ion gate can be eliminated from the setup by the use of Gas Electron Multiplier (GEM) foils for gas amplification, which intrinsically suppress the backflow of ions. This makes the continuous operation of a TPC at high rates feasible.
In this work, Monte Carlo simulations of the buildup of ion space charge in a GEM-based TPC and the correction of the resulting drift distortions are discussed, based on realistic numbers for the ion backflow in a triple-GEM amplification stack. A TPC in the future PANDA experiment at FAIR, in which antiproton-proton interaction rates up to 2 x 10^7 per second will be reached, serves as an example for the experimental environment. The simulations show that space charge densities up to 65 fC per cubic cm are reached, leading to electron drift distortions of up to 10 mm. The application of a laser calibration system to correct these distortions is investigated. Based on full simulations of the detector physics and response, we show that it is possible to correct for the drift distortions and to maintain the good momentum resolution of the GEM-TPC.
△ Less
Submitted 3 September, 2012;
originally announced September 2012.
-
Technical Design Study for the PANDA Time Projection Chamber
Authors:
M. Ball,
F. V. Böhmer,
S. Dørheim,
C. Höppner,
B. Ketzer,
I. Konorov,
S. Neubert,
S. Paul,
J. Rauch,
S. Uhl,
M. Vandenbroucke,
M. Berger,
J. -C. Berger-Chen,
F. Cusanno,
L. Fabbietti,
R. Münzer,
R. Arora,
J. Frühauf,
M. Kiš,
Y. Leifels,
V. Kleipa,
J. Hehner,
J. Kunkel,
N. Kurz,
K. Peters
, et al. (16 additional authors not shown)
Abstract:
This document illustrates the technical layout and the expected performance of a Time Projection Chamber as the central tracking system of the PANDA experiment. The detector is based on a continuously operating TPC with Gas Electron Multiplier (GEM) amplification.
This document illustrates the technical layout and the expected performance of a Time Projection Chamber as the central tracking system of the PANDA experiment. The detector is based on a continuously operating TPC with Gas Electron Multiplier (GEM) amplification.
△ Less
Submitted 29 June, 2012;
originally announced July 2012.
-
Technical Design Report for the: PANDA Straw Tube Tracker
Authors:
PANDA Collaboration,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher,
Y. Heng,
Z. Liu,
H. Liu,
X. Shen,
Q. Wang,
H. Xu,
A. Aab,
M. Albrecht,
J. Becker,
A. Csapó,
F. Feldbauer,
M. Fink,
P. Friedel,
F. H. Heinsius,
T. Held,
L. Klask,
H. Koch,
B. Kopf,
S. Leiber,
M. Leyhe
, et al. (451 additional authors not shown)
Abstract:
This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM-stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory an…
▽ More
This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM-stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory and the measurement of the specific energy-loss for a particle identification. Dedicated simulations with full analysis studies of certain proton-antiproton reactions, identified as being benchmark tests for the whole PANDA scientific program, have been performed to test the STT layout and performance. The results are presented, and the time lines to construct the STT are described.
△ Less
Submitted 4 June, 2012; v1 submitted 24 May, 2012;
originally announced May 2012.
-
The PANDA GEM-based TPC Prototype
Authors:
L. Fabbietti,
H. Angerer,
R. Beck,
M. Berger,
F. Böhmer,
K. T. Brinkmann,
P. Bühler,
M. Danner,
S. Dørheim,
C. Funke,
F. Cusanno,
J. Hehner,
A. Heinz,
M. Henske,
C. Höppner,
D. Kaiser,
B. Ketzer,
I. Konorov,
J. Kunkel,
M. Lang,
J. Marton,
S. Neubert,
S. Paul,
A. Schmah,
C. Schmidt
, et al. (15 additional authors not shown)
Abstract:
We report on the development of a GEM-based TPC prototype for the PANDA experiment. The design and requirements of this device will be illustrated, with particular emphasis on the properties of the recently tested GEM-detector, the characterization of the read-out electronics and the development of the tracking software that allows to evaluate the GEM-TPC data.
We report on the development of a GEM-based TPC prototype for the PANDA experiment. The design and requirements of this device will be illustrated, with particular emphasis on the properties of the recently tested GEM-detector, the characterization of the read-out electronics and the development of the tracking software that allows to evaluate the GEM-TPC data.
△ Less
Submitted 26 May, 2010; v1 submitted 23 April, 2010;
originally announced April 2010.
-
Development of a GEM-TPC prototype
Authors:
Heinz Angerer,
Reinhard Beck,
Martin Berger,
Felix Boehmer,
K. -T. Brinkmann,
Paul Buehler,
Michael Carnegie,
Sverre Dorheim,
Laura Fabbietti,
Chr. Funke,
F. Cusanno,
Joerg Hehner,
Andreas Heinz,
Markus Henske,
Christian Hoeppner,
David Kaiser,
Bernhard Ketzer,
Igor Konorov,
Jochen Kunkel,
Michael Lang,
Johann Marton,
Sebastian Neubert,
Stephan Paul,
Alexander Schmah,
Christian Schmidt
, et al. (15 additional authors not shown)
Abstract:
The use of GEM foils for the amplification stage of a TPC instead of a con- ventional MWPC allows one to bypass the necessity of gating, as the backdrift is suppressed thanks to the asymmetric field configuration. This way, a novel continuously running TPC, which represents one option for the PANDA central tracker, can be realized. A medium sized prototype with a diameter of 300 mm and a length…
▽ More
The use of GEM foils for the amplification stage of a TPC instead of a con- ventional MWPC allows one to bypass the necessity of gating, as the backdrift is suppressed thanks to the asymmetric field configuration. This way, a novel continuously running TPC, which represents one option for the PANDA central tracker, can be realized. A medium sized prototype with a diameter of 300 mm and a length of 600 mm will be tested inside the FOPI spectrometer at GSI using a carbon or lithium beam at intermediate energies (E = 1-3AGeV). This detector test under realistic experimental conditions should allow us to verify the spatial resolution for single tracks and the reconstruction capability for displaced vertexes. A series of physics measurement implying pion beams is scheduled with the FOPI spectrometer together with the GEM-TPC as well.
△ Less
Submitted 4 November, 2009;
originally announced November 2009.