-
Collisionless Shock Acceleration of protons in a plasma slab produced in a gas jet by the collision of two laser-driven hydrodynamic shockwaves
Authors:
J. -R. Marquès,
L. Lancia,
P. Loiseau,
P. Forestier-Colleoni,
M. Tarisien,
E. Atukpor,
V. Bagnoud,
C. Brabetz,
F. Consoli,
J. Domange,
F. Hannachi,
P. Nicolaï,
M. Salvadori,
B. Zielbauer
Abstract:
We recently proposed a new technique of plasma tailoring by laser-driven hydrodynamic shockwaves generated on both sides of a gas jet [J.-R. Marquès et al., Phys. Plasmas 28, 023103 (2021)]. In the continuation of this numerical work, we studied experimentally the influence of the tailoring on proton acceleration driven by a high-intensity picosecond-laser, in three cases: without tailoring, by ta…
▽ More
We recently proposed a new technique of plasma tailoring by laser-driven hydrodynamic shockwaves generated on both sides of a gas jet [J.-R. Marquès et al., Phys. Plasmas 28, 023103 (2021)]. In the continuation of this numerical work, we studied experimentally the influence of the tailoring on proton acceleration driven by a high-intensity picosecond-laser, in three cases: without tailoring, by tailoring only the entrance side of the ps-laser, or both sides of the gas jet. Without tailoring the acceleration is transverse to the laser axis, with a low-energy exponential spectrum, produced by Coulomb explosion. When the front side of the gas jet is tailored, a forward acceleration appears, that is significantly enhanced when both the front and back sides of the plasma are tailored. This forward acceleration produces higher energy protons, with a peaked spectrum, and is in good agreement with the mechanism of Collisionless Shock Acceleration (CSA). The spatio-temporal evolution of the plasma profile was characterized by optical shadowgraphy of a probe beam. The refraction and absorption of this beam was simulated by post-processing 3D hydrodynamic simulations of the plasma tailoring. Comparison with the experimental results allowed to estimate the thickness and near-critical density of the plasma slab produced by tailoring both sides of the gas jet. These parameters are in good agreement with those required for CSA.
△ Less
Submitted 28 September, 2023;
originally announced September 2023.
-
Development of a real-time tritium-in-water monitor
Authors:
C. D. R. Azevedo,
A. Baeza,
E. Chauveau,
J. A. Corbacho,
J. Díaz,
J. Domange,
C. Marquet,
M. Martínez-Roig,
F. Piquemal,
D. Prado,
J. F. C. A. Veloso,
N. Yahlali
Abstract:
In this paper, we report the development and performance of a detector module envisaging a tritium-in-water real-time activity monitor. The monitor is based on modular detection units whose number can be chosen according to the required sensitivity. The full system is being designed to achieve a \emph{Minimum Detectable Activity} (\emph{MDA}) of 100\,Bq/L of tritium-in-water activity which is the…
▽ More
In this paper, we report the development and performance of a detector module envisaging a tritium-in-water real-time activity monitor. The monitor is based on modular detection units whose number can be chosen according to the required sensitivity. The full system is being designed to achieve a \emph{Minimum Detectable Activity} (\emph{MDA}) of 100\,Bq/L of tritium-in-water activity which is the limit established by the E.U. Council Directive 2013/51/Euratom for water intended for human consumption. The same system can be used as a real-time pre-alert system for nuclear power plant regarding tritium-in water environmental surveillance. The first detector module was characterized, commissioned and installed immediately after the discharge channel of the Arrocampo dam (Almaraz nuclear power plant, Spain) on the Tagus river. Due to the high sensitivity of the single detection modules, the system requires radioactive background mitigation techniques through the use of active and passive shielding. We have extrapolated a \emph{MDA} of 3.6\,kBq/L for a single module being this value limited by the cosmic background. The obtained value for a single module is already compatible with a real-time environmental surveillance and pre-alert system. Further optimization of the single-module sensitivity will imply the reduction of the number of modules and the cost of the detector system.
△ Less
Submitted 5 December, 2023; v1 submitted 22 February, 2022;
originally announced February 2022.
-
Over-critical sharp-gradient plasma slab produced by the collision of laser-induced blast-waves in a gas jet; Application to high-energy proton acceleration
Authors:
J. -R. Marquès,
P. Loiseau,
J. Bonvalet,
M. Tarisien,
E. d'Humières,
J. Domange,
F. Hannachi,
L. Lancia,
O. Larroche,
P. Nicolaï P. Puyuelo-Valdes,
L. Romagnani,
J. Santos,
V. Tikhonchuk
Abstract:
The generation of thin and high density plasma slabs at high repetition rate is a key issue for ultra-high intensity laser applications. We present a scheme to create such plasma slabs, based on the propagation and collision in a gas jet of two counter-propagating blast waves (BW). Each BW is launched by a sudden and local heating induced by a nanosecond laser beam that propagates along the side o…
▽ More
The generation of thin and high density plasma slabs at high repetition rate is a key issue for ultra-high intensity laser applications. We present a scheme to create such plasma slabs, based on the propagation and collision in a gas jet of two counter-propagating blast waves (BW). Each BW is launched by a sudden and local heating induced by a nanosecond laser beam that propagates along the side of the jet. The resulting cylindrical BW expands perpendicular to the beam. The shock front, bent by the gas jet density gradient, pushes and compresses the plasma toward the jet center. By using two parallel ns laser beams, this scheme enables to tailor independently two opposite sides of the jet, while avoiding the damage risks associated with counterpropagating laser beams. A parametric study is performed using two and three dimensional hydrodynamic, as well as kinetic simulations. The BWs bending combined with the collision in a stagnation regime increases the density by more than 10 times and generates a very thin (down to few microns), near to over-critical plasma slab with a high density contrast (> 100), and a lifetime of a few hundred picoseconds. Two dimensional particle-in-cell simulations are used to study the influence of plasma tailoring on proton acceleration by a high-intensity sub-picosecond laser pulse. Tailoring the plasma not only at the entrance but also the exit side of the ps-pulse enhances the proton beam collimation, increases significantly the number of high energy protons, as well as their maximum energy.
△ Less
Submitted 30 September, 2020;
originally announced September 2020.
-
Simulation results on a real-time in water tritium monitor
Authors:
C. D. R. Azevedo,
A. Baeza,
E. Chauveau,
J. A. Corbacho,
J. Díaz,
J. Domange,
C. Marquet,
M. Martínez-Roig,
F. Piquemal,
J. F. C. A. Veloso,
N. Yahlali
Abstract:
In this work we present simulation results for a modular tritium in-water real-time monitor. The system allows for scalability in order to achieve the required sensitivity. The modules are composed by 340 uncladed scintillating fibers immersed in water and 2 photosensors for light readout. Light yield and Birks' coefficient uncertainties for low energy beta particles is discussed. A study of the d…
▽ More
In this work we present simulation results for a modular tritium in-water real-time monitor. The system allows for scalability in order to achieve the required sensitivity. The modules are composed by 340 uncladed scintillating fibers immersed in water and 2 photosensors for light readout. Light yield and Birks' coefficient uncertainties for low energy beta particles is discussed. A study of the detection efficiency according to the fiber length is presented. Discussion on the system requirements and background mitigation for a device with sensitivity of 100\,Bq/L, required to comply with the European directive 2013/51/Euratom, is presented. Due to the low energetic beta emission from tritium a detection efficiency close to 3.3\% was calculated for a single 2\,mm round fiber.
△ Less
Submitted 20 May, 2020; v1 submitted 14 February, 2020;
originally announced February 2020.
-
TRITIUM - A Real-Time Tritium Monitor System for Water Quality Surveillance
Authors:
C. D. R. Azevedo,
A. Baeza,
M. Bras,
T. Camara,
C. Cerna,
E. Chauveau,
J. M. Gil,
J. A. Corbacho,
V. Delgado,
J. Díaz,
J. Domange,
C. Marquet,
M. Martínez-Roig,
A. Moreno,
F. Piquemal,
A. Rodríguez,
J. Rodríguez,
C. Roldan,
J. F. C. A. Veloso,
N. Yahlali
Abstract:
In this work the development results of the TRITIUM project is presented. The main objective of the project is the construction of a near real-time monitor for low activity tritium in water, aimed at in-situ surveillance and radiological protection of river water in the vicinity of nuclear power plants. The European Council Directive 2013/51/Euratom requires that the maximum level of tritium in wa…
▽ More
In this work the development results of the TRITIUM project is presented. The main objective of the project is the construction of a near real-time monitor for low activity tritium in water, aimed at in-situ surveillance and radiological protection of river water in the vicinity of nuclear power plants. The European Council Directive 2013/51/Euratom requires that the maximum level of tritium in water for human consumption to be lower than 100 Bq/L. Tritium levels in the cooling water of nuclear power plants in normal operation are much higher than the levels caused by the natural and cosmogenic components, and may easily surmount the limit required by the Directive. The current liquid-scintillation measuring systems in environmental radioactivity laboratories are sensitive to such low levels, but they are not suitable for real-time monitoring. Moreover, there is no currently available device with enough sensitivity and monitoring capabilities that could be used for surveillance of the cooling water of nuclear power plants. A detector system based on scintillation fibers read out by photomultiplier tubes (PMTs) or silicon photomultiplier (SiPM) arrays is under development for in-water tritium measurement. This detector will be installed in the vicinity of Almaraz nuclear power plant (Spain) in Spring 2019. An overview of the project development and the results of first prototypes are presented.
△ Less
Submitted 14 February, 2019;
originally announced February 2019.
-
Background studies for the EDELWEISS dark matter experiment
Authors:
E. Armengaud,
C. Augier,
A. Benoît,
A. Benoît,
L. Bergé,
T. Bergmann,
J. Blümer,
A. Broniatowski,
V. Brudanin,
B. Censier,
M. Chapellier,
F. Charlieux,
F. Couedo,
P. Coulter,
G. A. Cox,
M. De Jesus,
J. Domange,
A. -A. Drilien,
L. Dumoulin,
K. Eitel,
D. Filosofov,
N. Fourches,
J. Gascon,
G. Gerbier,
M. Gros
, et al. (34 additional authors not shown)
Abstract:
The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter using cryogenic Ge detectors (400 g each) and 384 kg$\times$days of effective exposure. A cross-section of $4.4 \times 10^{-8}$ pb is excluded at 90% C.L. for a WIMP mass of 85 GeV. The next phase, EDELWEISS-III, aims to probe spin-independent WIMP-nucleon cross-sections down to a few $\times10^{-9}$ pb. We present h…
▽ More
The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter using cryogenic Ge detectors (400 g each) and 384 kg$\times$days of effective exposure. A cross-section of $4.4 \times 10^{-8}$ pb is excluded at 90% C.L. for a WIMP mass of 85 GeV. The next phase, EDELWEISS-III, aims to probe spin-independent WIMP-nucleon cross-sections down to a few $\times10^{-9}$ pb. We present here the study of gamma and neutron background coming from radioactive decays in the set-up and shielding materials. We have carried out Monte Carlo simulations for the completed EDELWEISS-II setup with GEANT4 and normalised the expected background rates to the measured radioactivity levels (or their upper limits) of all materials and components. The expected gamma-ray event rate in EDELWEISS-II at 20-200 keV agrees with the observed rate of 82 events/kg/day within the uncertainties in the measured concentrations. The calculated neutron rate from radioactivity of 1.0-3.1 events (90% C.L.) at 20-200 keV in the EDELWEISS-II data together with the expected upper limit on the misidentified gamma-ray events ($\le0.9$), surface betas ($\le0.3$), and muon-induced neutrons ($\le0.7$), do not contradict 5 observed events in nuclear recoil band. We have then extended the simulation framework to the EDELWEISS-III configuration with 800 g crystals, better material purity and additional neutron shielding inside the cryostat. The gamma-ray and neutron backgrounds in 24 kg fiducial mass of EDELWEISS-III have been calculated as 14-44 events/kg/day and 0.7-1.4 events per year, respectively. The results of the background studies performed in the present work have helped to select better purity components and improve shielding in EDELWEISS-III to further reduce the expected rate of background events in the next phase of the experiment.
△ Less
Submitted 15 May, 2013;
originally announced May 2013.
-
Muon-induced background in the EDELWEISS dark matter search
Authors:
The EDELWEISS collaboration,
B. Schmidt,
E. Armengaud,
C. Augier,
A. Benoit,
L. Bergé,
T. Bergmann,
J. Blümer,
G. Bres,
A. Broniatowski,
V. Brudanin,
B. Censier,
M. Chapellier,
F. Charlieux,
S. Collin,
P. Coulter,
G. A. Cox,
O. Crauste,
J. Domange,
L. Dumoulin,
K. Eitel,
D. Filosofov,
N. Fourches,
G. Garde,
J. Gascon
, et al. (33 additional authors not shown)
Abstract:
A dedicated analysis of the muon-induced background in the EDELWEISS dark matter search has been performed on a data set acquired in 2009 and 2010. The total muon flux underground in the Laboratoire Souterrain de Modane (LSM) was measured to be $Φ_μ=(5.4\pm 0.2 ^{+0.5}_{-0.9})$\,muons/m$^2$/d. The modular design of the muon-veto system allows the reconstruction of the muon trajectory and hence the…
▽ More
A dedicated analysis of the muon-induced background in the EDELWEISS dark matter search has been performed on a data set acquired in 2009 and 2010. The total muon flux underground in the Laboratoire Souterrain de Modane (LSM) was measured to be $Φ_μ=(5.4\pm 0.2 ^{+0.5}_{-0.9})$\,muons/m$^2$/d. The modular design of the muon-veto system allows the reconstruction of the muon trajectory and hence the determination of the angular dependent muon flux in LSM. The results are in good agreement with both MC simulations and earlier measurements. Synchronization of the muon-veto system with the phonon and ionization signals of the Ge detector array allowed identification of muon-induced events. Rates for all muon-induced events $Γ^μ=(0.172 \pm 0.012)\, \rm{evts}/(\rm{kg \cdot d})$ and of WIMP-like events $Γ^{μ-n} = 0.008^{+0.005}_{-0.004}\, \rm{evts}/(\rm{kg \cdot d})$ were extracted. After vetoing, the remaining rate of accepted muon-induced neutrons in the EDELWEISS-II dark matter search was determined to be $Γ^{μ-n}_{\rm irred} < 6\cdot 10^{-4} \, \rm{evts}/(\rm{kg \cdot d})$ at 90%\,C.L. Based on these results, the muon-induced background expectation for an anticipated exposure of 3000\,\kgd\ for EDELWEISS-3 is $N^{μ-n}_{3000 kg\cdot d} < 0.6$ events.
△ Less
Submitted 28 February, 2013;
originally announced February 2013.
-
A search for low-mass WIMPs with EDELWEISS-II heat-and-ionization detectors
Authors:
EDELWEISS Collaboration,
E. Armengaud,
C. Augier,
A. Benoît,
L. Bergé,
T. Bergmann,
J. Blümer,
A. Broniatowski,
V. Brudanin,
B. Censier,
M. Chapellier,
F. Charlieux,
F. Couëdo,
P. Coulter,
G. A. Cox,
J. Domange,
A. A. Drillien,
L. Dumoulin,
K. Eitel,
D. Filosofov,
N. Fourches,
J. Gascon,
G. Gerbier,
J. Gironnet,
M. Gros
, et al. (30 additional authors not shown)
Abstract:
We report on a search for low-energy (E < 20 keV) WIMP-induced nuclear recoils using data collected in 2009 - 2010 by EDELWEISS from four germanium detectors equipped with thermal sensors and an electrode design (ID) which allows to efficiently reject several sources of background. The data indicate no evidence for an exponential distribution of low-energy nuclear recoils that could be attributed…
▽ More
We report on a search for low-energy (E < 20 keV) WIMP-induced nuclear recoils using data collected in 2009 - 2010 by EDELWEISS from four germanium detectors equipped with thermal sensors and an electrode design (ID) which allows to efficiently reject several sources of background. The data indicate no evidence for an exponential distribution of low-energy nuclear recoils that could be attributed to WIMP elastic scattering after an exposure of 113 kg.d. For WIMPs of mass 10 GeV, the observation of one event in the WIMP search region results in a 90% CL limit of 1.0x10^-5 pb on the spin-independent WIMP-nucleon scattering cross-section, which constrains the parameter space associated with the findings reported by the CoGeNT, DAMA and CRESST experiments.
△ Less
Submitted 5 September, 2012; v1 submitted 7 July, 2012;
originally announced July 2012.
-
Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments
Authors:
CDMS,
EDELWEISS Collaborations,
:,
Z. Ahmed,
D. S. Akerib,
E. Armengaud,
S. Arrenberg,
C. Augier,
C. N. Bailey,
D. Balakishiyeva,
L. Baudis,
D. A. Bauer,
A. Benoît,
L. Bergé,
J. Blümer,
P. L. Brink,
A. Broniatowski,
T. Bruch,
V. Brudanin,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
B. Censier,
M. Chapellier,
G. Chardin
, et al. (92 additional authors not shown)
Abstract:
The CDMS and EDELWEISS collaborations have combined the results of their direct searches for dark matter using cryogenic germanium detectors. The total data set represents 614 kg.d equivalent exposure. A straightforward method of combination was chosen for its simplicity before data were exchanged between experiments. The results are interpreted in terms of limits on spin-independent WIMP-nucleon…
▽ More
The CDMS and EDELWEISS collaborations have combined the results of their direct searches for dark matter using cryogenic germanium detectors. The total data set represents 614 kg.d equivalent exposure. A straightforward method of combination was chosen for its simplicity before data were exchanged between experiments. The results are interpreted in terms of limits on spin-independent WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90% CL. At higher WIMP masses, the combination improves the individual limits, by a factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide stronger constraints for some ranges of WIMP masses and weaker constraints for others.
△ Less
Submitted 8 July, 2011; v1 submitted 17 May, 2011;
originally announced May 2011.
-
Final results of the EDELWEISS-II WIMP search using a 4-kg array of cryogenic germanium detectors with interleaved electrodes
Authors:
EDELWEISS Collaboration,
E. Armengaud,
C. Augier,
A. Benoît,
L. Bergé,
J. Blümer,
A. Broniatowski,
V. Brudanin,
B. Censier,
G. Chardin,
M. Chapellier,
F. Charlieux,
P. Coulter,
G. A. Cox,
X. Defay,
M. De Jesus,
Y. Dolgorouki,
J. Domange,
L. Dumoulin,
K. Eitel,
D. Filosofov,
N. Fourches,
J. Gascon,
G. Gerbier,
J. Gironnet
, et al. (27 additional authors not shown)
Abstract:
The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter with an array of ten 400-g cryogenic germanium detectors in operation at the Laboratoire Souterrain de Modane. The combined use of thermal phonon sensors and charge collection electrodes with an interleaved geometry enables the efficient rejection of gamma-induced radioactivity as well as near-surface interactions. A…
▽ More
The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter with an array of ten 400-g cryogenic germanium detectors in operation at the Laboratoire Souterrain de Modane. The combined use of thermal phonon sensors and charge collection electrodes with an interleaved geometry enables the efficient rejection of gamma-induced radioactivity as well as near-surface interactions. A total effective exposure of 384 kg.d has been achieved, mostly coming from fourteen months of continuous operation. Five nuclear recoil candidates are observed above 20 keV, while the estimated background is 3.0 events. The result is interpreted in terms of limits on the cross-section of spin-independent interactions of WIMPs and nucleons. A cross-section of 4.4x10^-8 pb is excluded at 90%CL for a WIMP mass of 85 GeV. New constraints are also set on models where the WIMP-nucleon scattering is inelastic.
△ Less
Submitted 31 August, 2011; v1 submitted 21 March, 2011;
originally announced March 2011.
-
A detection system to measure muon-induced neutrons for direct Dark Matter searches
Authors:
V. Yu. Kozlov,
E. Armengaud,
C. Augier,
A. Benoit,
L. Berge,
O. Besida,
J. Blumer,
A. Broniatowski,
V. Brudanin,
A. Chantelauze,
M. Chapellier,
G. Chardin,
F. Charlieux,
S. Collin,
X. Defay,
M. De Jesus,
P. Di Stefano,
Y. Dolgorouki,
J. Domange,
L. Dumoulin,
K. Eitel,
J. Gascon,
G. Gerbier,
M. Gros,
M. Hannawald
, et al. (19 additional authors not shown)
Abstract:
Muon-induced neutrons constitute a prominent background component in a number of low count rate experiments, namely direct searches for Dark Matter. In this work we describe a neutron detector to measure this background in an underground laboratory, the Laboratoire Souterrain de Modane. The system is based on 1 m3 of Gd-loaded scintillator and it is linked with the muon veto of the EDELWEISS-II ex…
▽ More
Muon-induced neutrons constitute a prominent background component in a number of low count rate experiments, namely direct searches for Dark Matter. In this work we describe a neutron detector to measure this background in an underground laboratory, the Laboratoire Souterrain de Modane. The system is based on 1 m3 of Gd-loaded scintillator and it is linked with the muon veto of the EDELWEISS-II experiment for coincident muon detection. The system was installed in autumn 2008 and passed since then a number of commissioning tests proving its full functionality. The data-taking is continuously ongoing and a count rate of the order of 1 muon-induced neutron per day has been achieved.
△ Less
Submitted 15 June, 2010;
originally announced June 2010.
-
Monitoring of the thermal neutron flux in the LSM underground laboratory
Authors:
S. Rozov,
E. Armengaud,
C. Augier,
L. Bergé,
A. Benoit,
O. Besida,
J. Blümer,
A. Broniatowski,
V. Brudanin,
A. Chantelauze,
M. Chapellier,
G. Chardin,
F. Charlieux,
S. Collin,
O. Crauste,
M. De Jesus,
X. Defay,
P. Di Stefano,
Y. Dolgorouki,
J. Domange,
L. Dumoulin,
K. Eitel,
D. Filosofov,
J. Gascon,
G. Gerbier
, et al. (20 additional authors not shown)
Abstract:
This paper describes precise measurements of the thermal neutron flux in the LSM underground laboratory in proximity of the EDELWEISS-II dark matter search experiment together with short measurements at various other locations. Monitoring of the flux of thermal neutrons is accomplished using a mobile detection system with low background proportional counter filled with $^3$He. On average 75 neut…
▽ More
This paper describes precise measurements of the thermal neutron flux in the LSM underground laboratory in proximity of the EDELWEISS-II dark matter search experiment together with short measurements at various other locations. Monitoring of the flux of thermal neutrons is accomplished using a mobile detection system with low background proportional counter filled with $^3$He. On average 75 neutrons per day are detected with a background level below 1 count per day (cpd). This provides a unique possibility of a day by day study of variations of the neutron field in a deep underground site. The measured average 4$π$ neutron flux per cm$^{2}$ in the proximity of EDELWEISS-II is $Φ_{MB}=3.57\pm0.05^{stat}\pm0.27^{syst}\times 10^{-6}$ neutrons/sec. We report the first experimental observation that the point-to-point thermal neutron flux at LSM varies by more than a factor two.
△ Less
Submitted 25 January, 2010;
originally announced January 2010.
-
First results of the EDELWEISS-II WIMP search using Ge cryogenic detectors with interleaved electrodes
Authors:
E. Armengaud,
C. Augier,
A. Benoit,
L. Berge,
O. Besida,
J. Blumer,
A. Broniatowski,
A. Chantelauze,
M. Chapellier,
G. Chardin,
F. Charlieux,
S. Collin,
X. Defay,
M. De Jesus,
P. Di Stefano,
Y. Dolgorouki,
J. Domange,
L. Dumoulin,
K. Eitel,
J. Gascon,
G. Gerbier,
M. Gros,
M. Hannawald,
S. Herve,
A. Juillard
, et al. (19 additional authors not shown)
Abstract:
The EDELWEISS-II collaboration has performed a direct search for WIMP dark matter with an array of ten 400 g heat-and-ionization cryogenic detectors equipped with interleaved electrodes for the rejection of near-surface events. Six months of continuous operation at the Laboratoire Souterrain de Modane have been achieved. The observation of one nuclear recoil candidate above 20 keV in an effectiv…
▽ More
The EDELWEISS-II collaboration has performed a direct search for WIMP dark matter with an array of ten 400 g heat-and-ionization cryogenic detectors equipped with interleaved electrodes for the rejection of near-surface events. Six months of continuous operation at the Laboratoire Souterrain de Modane have been achieved. The observation of one nuclear recoil candidate above 20 keV in an effective exposure of 144 kgd is interpreted in terms of limits on the cross-section of spin-independent interactions of WIMPs and nucleons. A cross-section of 1.0x10^-7 pb is excluded at 90%CL for a WIMP mass of 80 GeV/c2. This result demonstrates for the first time the very high background rejection capabilities of these simple and robust detectors in an actual WIMP search experiment.
△ Less
Submitted 4 December, 2009;
originally announced December 2009.
-
A new high-background-rejection dark matter Ge cryogenic detector
Authors:
A. Broniatowski,
X. Defay,
E. Armengaud,
L. Berge,
A. Benoit,
O. Besida,
J. Blumer,
A. Chantelauze,
M. Chapellier,
G. Chardin,
F. Charlieux,
S. Collin,
O. Crauste,
M. De Jesus,
P. Di Stefano,
Y. Dolgorouki,
J. Domange,
L. Dumoulin,
K. Eitel,
J. Gascon,
G. Gerbier,
M. Gros,
M. Hannawald,
S. Herve,
A. Juillard
, et al. (18 additional authors not shown)
Abstract:
A new design of a cryogenic germanium detector for dark matter search is presented, taking advantage of the coplanar grid technique of event localisation for improved background discrimination. Experiments performed with prototype devices in the EDELWEISS II setup at the Modane underground facility demonstrate the remarkably high efficiency of these devices for the rejection of low-energy $β$, a…
▽ More
A new design of a cryogenic germanium detector for dark matter search is presented, taking advantage of the coplanar grid technique of event localisation for improved background discrimination. Experiments performed with prototype devices in the EDELWEISS II setup at the Modane underground facility demonstrate the remarkably high efficiency of these devices for the rejection of low-energy $β$, approaching 10$^5$ . This opens the road to investigate the range beyond 10$^{-8}$ pb in the WIMP-nucleon collision cross-sections, as proposed in the EURECA project of a one-ton cryogenic detector mass.
△ Less
Submitted 6 May, 2009;
originally announced May 2009.
-
Proceedings of the 1st International Workshop "Radiopure Scintillators for EURECA" (RPScint'2008)
Authors:
E. Armengau,
M. Bauer,
I. Bavykina,
A. Benoit,
A. Bento,
J. Blumer,
L. Bornschein,
A. Broniatowski,
G. Burghart,
P. Camus,
A. Chantelauze,
M. Chapellier,
G. Chardin,
C. Ciemniak,
C. Coppi,
N. Coron,
O. Crauste,
F. A. Danevich,
E. Daw,
X. Defay,
M. De Jesus,
P. de Marcillac,
G. Deuter,
J. Domange,
P. Di Stefano
, et al. (34 additional authors not shown)
Abstract:
Workshop RPSCINT'2008 was organized in Kyiv (Ukraine) on 9th and 10th September 2008. The idea was to bring together physicists, chemists, crystal scintillator experts and manufacturers to discuss the requirements of low-count rate experiments, in particular the required radiopurity and scintillation properties; selection and screening of input materials; purification of materials; raw compound…
▽ More
Workshop RPSCINT'2008 was organized in Kyiv (Ukraine) on 9th and 10th September 2008. The idea was to bring together physicists, chemists, crystal scintillator experts and manufacturers to discuss the requirements of low-count rate experiments, in particular the required radiopurity and scintillation properties; selection and screening of input materials; purification of materials; raw compound preparation; crystal growing, annealing and handling; test of crystals; search for and development of new scintillating materials. Some contributions to the RPSCINT 2008 workshop are presented in these proceedings.
△ Less
Submitted 9 March, 2009; v1 submitted 9 March, 2009;
originally announced March 2009.