ECG Feature Importance Rankings: Cardiologists vs. Algorithms
Authors:
Temesgen Mehari,
Ashish Sundar,
Alen Bosnjakovic,
Peter Harris,
Steven E. Williams,
Axel Loewe,
Olaf Doessel,
Claudia Nagel,
Nils Strodthoff,
Philip J. Aston
Abstract:
Feature importance methods promise to provide a ranking of features according to importance for a given classification task. A wide range of methods exist but their rankings often disagree and they are inherently difficult to evaluate due to a lack of ground truth beyond synthetic datasets. In this work, we put feature importance methods to the test on real-world data in the domain of cardiology,…
▽ More
Feature importance methods promise to provide a ranking of features according to importance for a given classification task. A wide range of methods exist but their rankings often disagree and they are inherently difficult to evaluate due to a lack of ground truth beyond synthetic datasets. In this work, we put feature importance methods to the test on real-world data in the domain of cardiology, where we try to distinguish three specific pathologies from healthy subjects based on ECG features comparing to features used in cardiologists' decision rules as ground truth. Some methods generally performed well and others performed poorly, while some methods did well on some but not all of the problems considered.
△ Less
Submitted 5 April, 2023;
originally announced April 2023.
-
MedalCare-XL: 16,900 healthy and pathological 12 lead ECGs obtained through electrophysiological simulations
Authors:
Karli Gillette,
Matthias A. F. Gsell,
Claudia Nagel,
Jule Bender,
Bejamin Winkler,
Steven E. Williams,
Markus Bär,
Tobias Schäffter,
Olaf Dössel,
Gernot Plank,
Axel Loewe
Abstract:
Mechanistic cardiac electrophysiology models allow for personalized simulations of the electrical activity in the heart and the ensuing electrocardiogram (ECG) on the body surface. As such, synthetic signals possess known ground truth labels of the underlying disease and can be employed for validation of machine learning ECG analysis tools in addition to clinical signals. Recently, synthetic ECGs…
▽ More
Mechanistic cardiac electrophysiology models allow for personalized simulations of the electrical activity in the heart and the ensuing electrocardiogram (ECG) on the body surface. As such, synthetic signals possess known ground truth labels of the underlying disease and can be employed for validation of machine learning ECG analysis tools in addition to clinical signals. Recently, synthetic ECGs were used to enrich sparse clinical data or even replace them completely during training leading to improved performance on real-world clinical test data. We thus generated a novel synthetic database comprising a total of 16,900 12 lead ECGs based on electrophysiological simulations equally distributed into healthy control and 7 pathology classes. The pathological case of myocardial infraction had 6 sub-classes. A comparison of extracted features between the virtual cohort and a publicly available clinical ECG database demonstrated that the synthetic signals represent clinical ECGs for healthy and pathological subpopulations with high fidelity. The ECG database is split into training, validation, and test folds for development and objective assessment of novel machine learning algorithms.
△ Less
Submitted 29 November, 2022;
originally announced November 2022.
-
Non-invasive Localization of the Ventricular Excitation Origin Without Patient-specific Geometries Using Deep Learning
Authors:
Nicolas Pilia,
Steffen Schuler,
Maike Rees,
Gerald Moik,
Danila Potyagaylo,
Olaf Dössel,
Axel Loewe
Abstract:
Ventricular tachycardia (VT) can be one cause of sudden cardiac death affecting 4.25 million persons per year worldwide. A curative treatment is catheter ablation in order to inactivate the abnormally triggering regions. To facilitate and expedite the localization during the ablation procedure, we present two novel localization techniques based on convolutional neural networks (CNNs). In contrast…
▽ More
Ventricular tachycardia (VT) can be one cause of sudden cardiac death affecting 4.25 million persons per year worldwide. A curative treatment is catheter ablation in order to inactivate the abnormally triggering regions. To facilitate and expedite the localization during the ablation procedure, we present two novel localization techniques based on convolutional neural networks (CNNs). In contrast to existing methods, e.g. using ECG imaging, our approaches were designed to be independent of the patient-specific geometries and directly applicable to surface ECG signals, while also delivering a binary transmural position. One method outputs ranked alternative solutions. Results can be visualized either on a generic or patient geometry. The CNNs were trained on a data set containing only simulated data and evaluated both on simulated and clinical test data. On simulated data, the median test error was below 3mm. The median localization error on the clinical data was as low as 32mm. The transmural position was correctly detected in up to 82% of all clinical cases. Using the ranked alternative solutions, the top-3 median error dropped to 20mm on clinical data. These results demonstrate a proof of principle to utilize CNNs to localize the activation source without the intrinsic need of patient-specific geometrical information. Furthermore, delivering multiple solutions can help the physician to find the real activation source amongst more than one possible locations. With further optimization, these methods have a high potential to speed up clinical interventions. Consequently they could decrease procedural risk and improve VT patients' outcomes.
△ Less
Submitted 16 September, 2022;
originally announced September 2022.
-
Comparison of propagation models and forward calculation methods on cellular, tissue and organ scale atrial electrophysiology
Authors:
Claudia Nagel,
Cristian Barrios Espinosa,
Karli Gillette,
Matthias A. F. Gsell,
Jorge Sánchez,
Gernot Plank,
Olaf Dössel,
Axel Loewe
Abstract:
Objective: The bidomain model and the finite element method are an established standard to mathematically describe cardiac electrophysiology, but are both suboptimal choices for fast and large-scale simulations due to high computational costs. We investigate to what extent simplified approaches for propagation models (monodomain, reaction-eikonal and eikonal) and forward calculation (boundary elem…
▽ More
Objective: The bidomain model and the finite element method are an established standard to mathematically describe cardiac electrophysiology, but are both suboptimal choices for fast and large-scale simulations due to high computational costs. We investigate to what extent simplified approaches for propagation models (monodomain, reaction-eikonal and eikonal) and forward calculation (boundary element and infinite volume conductor) deliver markedly accelerated, yet physiologically accurate simulation results in atrial electrophysiology. Methods: We compared action potential durations, local activation times (LATs), and electrocardiograms (ECGs) for sinus rhythm simulations on healthy and fibrotically infiltrated atrial models. Results: All simplified model solutions yielded LATs and P waves in accurate accordance with the bidomain results. Only for the eikonal model with pre-computed action potential templates shifted in time to derive transmembrane voltages, repolarization behavior notably deviated from the bidomain results. ECGs calculated with the boundary element method were characterized by correlation coefficients >0.9 compared to the finite element method. The infinite volume conductor method led to lower correlation coefficients caused predominantly by systematic overestimations of P wave amplitudes in the precordial leads. Conclusion: Our results demonstrate that the eikonal model yields accurate LATs and combined with the boundary element method precise ECGs compared to markedly more expensive full bidomain simulations. However, for an accurate representation of atrial repolarization dynamics, diffusion terms must be accounted for in simplified models. Significance: Simulations of atrial LATs and ECGs can be notably accelerated to clinically feasible time frames at high accuracy by resorting to the eikonal and boundary element methods.
△ Less
Submitted 15 March, 2022;
originally announced March 2022.
-
Reducing Line-of-block Artifacts in Cardiac Activation Maps Estimated Using ECG Imaging: A Comparison of Source Models and Estimation Methods
Authors:
Steffen Schuler,
Matthias Schaufelberger,
Laura R. Bear,
Jake A. Bergquist,
Matthijs J. M. Cluitmans,
Jaume Coll-Font,
Önder N. Onak,
Brian Zenger,
Axel Loewe,
Rob S. MacLeod,
Dana H. Brooks,
Olaf Dössel
Abstract:
Objective: To investigate cardiac activation maps estimated using electrocardiographic imaging and to find methods reducing line-of-block (LoB) artifacts, while preserving real LoBs. Methods: Body surface potentials were computed for 137 simulated ventricular excitations. Subsequently, the inverse problem was solved to obtain extracellular potentials (EP) and transmembrane voltages (TMV). From the…
▽ More
Objective: To investigate cardiac activation maps estimated using electrocardiographic imaging and to find methods reducing line-of-block (LoB) artifacts, while preserving real LoBs. Methods: Body surface potentials were computed for 137 simulated ventricular excitations. Subsequently, the inverse problem was solved to obtain extracellular potentials (EP) and transmembrane voltages (TMV). From these, activation times (AT) were estimated using four methods and compared to the ground truth. This process was evaluated with two cardiac mesh resolutions. Factors contributing to LoB artifacts were identified by analyzing the impact of spatial and temporal smoothing on the morphology of source signals. Results: AT estimation using a spatiotemporal derivative performed better than using a temporal derivative. Compared to deflection-based AT estimation, correlation-based methods were less prone to LoB artifacts but performed worse in identifying real LoBs. Temporal smoothing could eliminate artifacts for TMVs but not for EPs, which could be linked to their temporal morphology. TMVs led to more accurate ATs on the septum than EPs. Mesh resolution had a negligible effect on inverse reconstructions, but small distances were important for cross-correlation-based estimation of AT delays. Conclusion: LoB artifacts are mainly caused by the inherent spatial smoothing effect of the inverse reconstruction. Among the configurations evaluated, only deflection-based AT estimation in combination with TMVs and strong temporal smoothing can prevent LoB artifacts, while preserving real LoBs. Significance: Regions of slow conduction are of considerable clinical interest and LoB artifacts observed in non-invasive ATs can lead to misinterpretations. We addressed this problem by identifying factors causing such artifacts and methods to reduce them.
△ Less
Submitted 22 December, 2021; v1 submitted 14 August, 2021;
originally announced August 2021.
-
A bi-atrial statistical shape model for large-scale in silico studies of human atria: model development and application to ECG simulations
Authors:
Claudia Nagel,
Steffen Schuler,
Olaf Dössel,
Axel Loewe
Abstract:
Large-scale electrophysiological simulations to obtain electrocardiograms (ECG) carry the potential to produce extensive datasets for training of machine learning classifiers to, e.g., discriminate between different cardiac pathologies. The adoption of simulations for these purposes is limited due to a lack of ready-to-use models covering atrial anatomical variability. We built a bi-atrial statist…
▽ More
Large-scale electrophysiological simulations to obtain electrocardiograms (ECG) carry the potential to produce extensive datasets for training of machine learning classifiers to, e.g., discriminate between different cardiac pathologies. The adoption of simulations for these purposes is limited due to a lack of ready-to-use models covering atrial anatomical variability. We built a bi-atrial statistical shape model (SSM) of the endocardial wall based on 47 segmented human CT and MRI datasets using Gaussian process morphable models. Generalization, specificity, and compactness metrics were evaluated. The SSM was applied to simulate atrial ECGs in 100 random volumetric instances. The first eigenmode of our SSM reflects a change of the total volume of both atria, the second the asymmetry between left vs. right atrial volume, the third a change in the prominence of the atrial appendages. The SSM is capable of generalizing well to unseen geometries and 95% of the total shape variance is covered by its first 23 eigenvectors. The P waves in the 12-lead ECG of 100 random instances showed a duration of 104ms in accordance with large cohort studies. The novel bi-atrial SSM itself as well as 100 exemplary instances with rule-based augmentation of atrial wall thickness, fiber orientation, inter-atrial bridges and tags for anatomical structures have been made publicly available. The novel, openly available bi-atrial SSM can in future be employed to generate large sets of realistic atrial geometries as a basis for in silico big data approaches.
△ Less
Submitted 22 February, 2021;
originally announced February 2021.
-
Reconstruction of Potassium Concentrations with the ECG on Imbalanced Datasets
Authors:
Nicolas Pilia,
Cristiana Corsi,
Stefano Severi,
Olaf Dössel,
Axel Loewe
Abstract:
End-stage chronic kidney disease (CKD) patients are facing a 30% rise for the risk of lethal cardiac events (LCE) compared to non-CKD patients. At the same time, these patients undergoing dialysis experience shifts in the potassium concentrations. The increased risk of LCE paired with the concentration changes suggest a connection between LCE and concentration disbalances. To prove this link, a co…
▽ More
End-stage chronic kidney disease (CKD) patients are facing a 30% rise for the risk of lethal cardiac events (LCE) compared to non-CKD patients. At the same time, these patients undergoing dialysis experience shifts in the potassium concentrations. The increased risk of LCE paired with the concentration changes suggest a connection between LCE and concentration disbalances. To prove this link, a continuous monitoring device for the ionic concentrations, e.g. the ECG, is needed. In this work, we want to answer if an optimised signal processing chain can improve the result quantify the influence of a disbalanced training dataset on the final estimation result. The study was performed on a dataset consisting of 12-lead ECGs recorded during dialysis sessions of 32 patients. We selected three features to find a mapping from ECG features to [K+]o: T-wave ascending slope, T-wave descending slope and T-wave amplitude. A polynomial model of 3rd order was used to reconstruct the concentrations from these features. We solved a regularised weighted least squares problem with a weighting matrix dependent on the frequency of each concentration in the dataset (frequent concentration weighted less). By doing so, we tried to generate a model being suitable for the whole range of the concentrations.With weighting, errors are increasing for the whole dataset. For the data partition with [K+]o<5 mmol/l, errors are increasing, for [K+]o$\geq$5 mmol/l, errors are decreasing. However, and apart from the exact reconstruction results, we can conclude that a model being valid for all patients and not only the majority, needs to be learned with a more homogeneous dataset. This can be achieved by leaving out data points or by weighting the errors during the model fitting. With increasing weighting, we increase the performance on the part of the [K+]o that are less frequent which was desired in our case.
△ Less
Submitted 9 June, 2020;
originally announced June 2020.