-
Investigation of infrasound noise background at Mátra Gravitational and Geophysical Laboratory (MGGL)
Authors:
Edit Fenyvesi,
József Molnár,
Sándor Czellár
Abstract:
Infrasonic and seismic waves are supposed to be the main contributors to the gravity-gradient noise (Newtonian noise) of the third generation subterranean gravitational-wave detectors. This noise will limit the sensitivity of the instrument at frequencies below 20 Hz. Investigation of its origin and the possible methods of mitigation have top priority during the designing period of the detectors.…
▽ More
Infrasonic and seismic waves are supposed to be the main contributors to the gravity-gradient noise (Newtonian noise) of the third generation subterranean gravitational-wave detectors. This noise will limit the sensitivity of the instrument at frequencies below 20 Hz. Investigation of its origin and the possible methods of mitigation have top priority during the designing period of the detectors. Therefore long-term site characterizing measurements are needed at several subterranean sites. However, at some sites, mining activities can occur. These activities can cause sudden changes (transients) in the measured signal, and increase the continuous background noise, too. We have developed a new algorithm based on discrete Haar transform to find these transients in the infrasound signal. We found that eliminating the transients decreases the variation of the noise spectra, and hence results a more accurate characterization of the background noise. We also carried out experiments for controlling the continuous noise. Machines operating at the mine was turned on and off systematically in order to see their effect on the noise spectra. These experiments showed that the main contributor of the continuous noise is the ventilation system of the mine.
△ Less
Submitted 30 June, 2019;
originally announced July 2019.
-
Long term measurements from the Mátra Gravitational and Geophysical Laboratory
Authors:
P. Ván,
G. G. Barnaföldi,
T. Bulik,
T. Biró,
S. Czellár,
M. Cieślar,
Cs. Czanik,
E. Dávid,
E. Debreceni,
M. Denys,
M. Dobróka,
E. Fenyvesi,
D. Gondek-Rosińska,
Z. Gráczer,
G. Hamar,
G. Huba,
B. Kacskovics,
Á. Kis,
I. Kovács,
R. Kovács,
I. Lemperger,
P. Lévai,
S. Lökös,
J. Mlynarczyk,
J. Molnár
, et al. (15 additional authors not shown)
Abstract:
Summary of the long term data taking, related to one of the proposed next generation ground-based gravitational detector's location is presented here. Results of seismic and infrasound noise, electromagnetic attenuation and cosmic muon radiation measurements are reported in the underground Matra Gravitational and Geophysical Laboratory near Gyöngyösoroszi, Hungary. The collected seismic data of mo…
▽ More
Summary of the long term data taking, related to one of the proposed next generation ground-based gravitational detector's location is presented here. Results of seismic and infrasound noise, electromagnetic attenuation and cosmic muon radiation measurements are reported in the underground Matra Gravitational and Geophysical Laboratory near Gyöngyösoroszi, Hungary. The collected seismic data of more than two years is evaluated from the point of view of the Einstein Telescope, a proposed third generation underground gravitational wave observatory. Applying our results for the site selection will significantly improve the signal to nose ratio of the multi-messenger astrophysics era, especially at the low frequency regime.
△ Less
Submitted 13 November, 2018;
originally announced November 2018.
-
A novel application of Fiber Bragg Grating (FBG) sensors in MPGD
Authors:
D. Abbaneo,
M. Abbas,
M. Abbrescia,
A. A. Abdelalim,
M. Abi Akl,
O. Aboamer,
D. Acosta,
A. Ahmad,
W. Ahmed,
W. Ahmed,
A. Aleksandrov,
R. Aly,
P. Altieri,
C. Asawatangtrakuldee,
P. Aspell,
Y. Assran,
I. Awan,
S. Bally,
Y. Ban,
S. Banerjee,
V. Barashko,
P. Barria,
G. Bencze,
N. Beni,
L. Benussi
, et al. (133 additional authors not shown)
Abstract:
We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active are…
▽ More
We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active area each, employing three GEM foils per chamber, to be installed in the forward region of the CMS endcap during the long shutdown of LHC in 2108-2019. The large active area of each GE1/1 chamber consists of GEM foils that are mechanically stretched in order to secure their flatness and the consequent uniform performance of the GE1/1 chamber across its whole active surface. So far FBGs have been used in high energy physics mainly as high precision positioning and re-positioning sensors and as low cost, easy to mount, low space consuming temperature sensors. FBGs are also commonly used for very precise strain measurements in material studies. In this work we present a novel use of FBGs as flatness and mechanical tensioning sensors applied to the wide GEM foils of the GE1/1 chambers. A network of FBG sensors have been used to determine the optimal mechanical tension applied and to characterise the mechanical tension that should be applied to the foils. We discuss the results of the test done on a full-sized GE1/1 final prototype, the studies done to fully characterise the GEM material, how this information was used to define a standard assembly procedure and possible future developments.
△ Less
Submitted 28 December, 2015;
originally announced December 2015.
-
Fiber Bragg Grating (FBG) sensors as flatness and mechanical stretching sensors
Authors:
D. Abbaneo,
M. Abbas,
M. Abbrescia,
A. A. Abdelalim,
M. Abi Akl,
O. Aboamer,
D. Acosta,
A. Ahmad,
W. Ahmed,
W. Ahmed,
A. Aleksandrov,
R. Aly,
P. Altieri,
C. Asawatangtrakuldee,
P. Aspell,
Y. Assran,
I. Awan,
S. Bally,
Y. Ban,
S. Banerjee,
V. Barashko,
P. Barria,
G. Bencze,
N. Beni,
L. Benussi
, et al. (133 additional authors not shown)
Abstract:
A novel approach which uses Fibre Bragg Grating (FBG) sensors has been utilised to assess and monitor the flatness of Gaseous Electron Multipliers (GEM) foils. The setup layout and preliminary results are presented.
A novel approach which uses Fibre Bragg Grating (FBG) sensors has been utilised to assess and monitor the flatness of Gaseous Electron Multipliers (GEM) foils. The setup layout and preliminary results are presented.
△ Less
Submitted 28 December, 2015;
originally announced December 2015.
-
Observation of the rare $B^0_s\toμ^+μ^-$ decay from the combined analysis of CMS and LHCb data
Authors:
The CMS,
LHCb Collaborations,
:,
V. Khachatryan,
A. M. Sirunyan,
A. Tumasyan,
W. Adam,
T. Bergauer,
M. Dragicevic,
J. Erö,
M. Friedl,
R. Frühwirth,
V. M. Ghete,
C. Hartl,
N. Hörmann,
J. Hrubec,
M. Jeitler,
W. Kiesenhofer,
V. Knünz,
M. Krammer,
I. Krätschmer,
D. Liko,
I. Mikulec,
D. Rabady,
B. Rahbaran
, et al. (2807 additional authors not shown)
Abstract:
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six sta…
▽ More
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six standard deviations, and the best measurement of its branching fraction so far. Furthermore, evidence for the $B^0\toμ^+μ^-$ decay is obtained with a statistical significance of three standard deviations. The branching fraction measurements are statistically compatible with SM predictions and impose stringent constraints on several theories beyond the SM.
△ Less
Submitted 17 August, 2015; v1 submitted 17 November, 2014;
originally announced November 2014.
-
Czochralski Silicon as a Detector Material for S-LHC Tracker Volumes
Authors:
Leonard Spiegel,
Tobias Barvich,
Burt Betchart,
Saptaparna Bhattacharya,
Sandor Czellar,
Regina Demina,
Alexander Dierlamm,
Martin Frey,
Yuri Gotra,
Jaakko Härkönen,
Frank Hartmann,
Ivan Kassamakov,
Sergey Korjenevski,
Matti J. Kortelainen,
Tapio Lampén,
Teppo Mäenpää,
Henri Moilanen,
Meenakshi Narain,
Maike Neuland,
Douglas Orbaker,
Hans-Jürgen Simonis,
Pia Steck,
Eija Tuominen,
Esa Tuovinen
Abstract:
With an expected ten-fold increase in luminosity in S-LHC, the radiation environment in the tracker volumes will be considerably harsher for silicon-based detectors than the already harsh LHC environment. Since 2006, a group of CMS institutes, using a modified CMS DAQ system, has been exploring the use of Magnetic Czochralski silicon as a detector element for the strip tracker layers in S-LHC expe…
▽ More
With an expected ten-fold increase in luminosity in S-LHC, the radiation environment in the tracker volumes will be considerably harsher for silicon-based detectors than the already harsh LHC environment. Since 2006, a group of CMS institutes, using a modified CMS DAQ system, has been exploring the use of Magnetic Czochralski silicon as a detector element for the strip tracker layers in S-LHC experiments. Both p+/n-/n+ and n+/p-/p+ sensors have been characterized, irradiated with proton and neutron sources, assembled into modules, and tested in a CERN beamline. There have been three beam studies to date and results from these suggest that both p+/n-/n+ and n+/p-/p+ Magnetic Czochralski silicon are sufficiently radiation hard for the $R>25$ cm regions of S-LHC tracker volumes. The group has also explored the use of forward biasing for heavily irradiated detectors, and although this mode requires sensor temperatures less than -50\,$^\circ$C, the charge collection efficiency appears to be promising.
△ Less
Submitted 24 August, 2010;
originally announced August 2010.
-
Novel Data Acquisition System for Silicon Tracking Detectors
Authors:
L. A. Wendland,
K. Banzuzi,
S. Czellar,
A. Heikkinen,
J. Harkonen,
P. Johansson,
V. Karimaki,
T. Lampen,
P. Luukka,
P. Mehtala,
J. Niku,
S. Nummela,
J. Nysten,
J. Simpura,
E. Tuovinen,
E. Tuominen,
J. Tuominiemi,
D. Ungaro,
T. Vaarala,
M. Voutilainen,
A. Zibellini
Abstract:
We have developed a novel data acquisition system for measuring tracking parameters of a silicon detector in a particle beam. The system is based on a commercial Analog-to-Digital VME module and a PC Linux based Data Acquisition System. This DAQ is realized with C++ code using object-oriented techniques. Track parameters for the beam particles were reconstructed using off-line analysis code and…
▽ More
We have developed a novel data acquisition system for measuring tracking parameters of a silicon detector in a particle beam. The system is based on a commercial Analog-to-Digital VME module and a PC Linux based Data Acquisition System. This DAQ is realized with C++ code using object-oriented techniques. Track parameters for the beam particles were reconstructed using off-line analysis code and automatic detector position alignment algorithm.
The new DAQ was used to test novel Czochralski type silicon detectors. The important silicon detector parameters, including signal size distributions and signal to noise distributions, were successfully extracted from the detector under study. The efficiency of the detector was measured to be 95 %, the resolution about 10 micrometers, and the signal to noise ratio about 10.
△ Less
Submitted 2 June, 2003;
originally announced June 2003.