Technical Design Report of the Spin Physics Detector at NICA
Authors:
The SPD Collaboration,
V. Abazov,
V. Abramov,
L. Afanasyev,
R. Akhunzyanov,
A. Akindinov,
I. Alekseev,
A. Aleshko,
V. Alexakhin,
G. Alexeev,
L. Alimov,
A. Allakhverdieva,
A. Amoroso,
V. Andreev,
V. Andreev,
E. Andronov,
Yu. Anikin,
S. Anischenko,
A. Anisenkov,
V. Anosov,
E. Antokhin,
A. Antonov,
S. Antsupov,
A. Anufriev,
K. Asadova
, et al. (392 additional authors not shown)
Abstract:
The Spin Physics Detector collaboration proposes to install a universal detector in the second interaction point of the NICA collider under construction (JINR, Dubna) to study the spin structure of the proton and deuteron and other spin-related phenomena using a unique possibility to operate with polarized proton and deuteron beams at a collision energy up to 27 GeV and a luminosity up to…
▽ More
The Spin Physics Detector collaboration proposes to install a universal detector in the second interaction point of the NICA collider under construction (JINR, Dubna) to study the spin structure of the proton and deuteron and other spin-related phenomena using a unique possibility to operate with polarized proton and deuteron beams at a collision energy up to 27 GeV and a luminosity up to $10^{32}$ cm$^{-2}$ s$^{-1}$. As the main goal, the experiment aims to provide access to the gluon TMD PDFs in the proton and deuteron, as well as the gluon transversity distribution and tensor PDFs in the deuteron, via the measurement of specific single and double spin asymmetries using different complementary probes such as charmonia, open charm, and prompt photon production processes. Other polarized and unpolarized physics is possible, especially at the first stage of NICA operation with reduced luminosity and collision energy of the proton and ion beams. This document is dedicated exclusively to technical issues of the SPD setup construction.
△ Less
Submitted 28 May, 2024; v1 submitted 12 April, 2024;
originally announced April 2024.
-
Exposing a fibre-based dual-readout calorimeter to a positron beam
Authors:
N. Ampilogov,
S. Cometti,
J. Agarwala,
V. Chmill,
R. Ferrari,
G. Gaudio,
P. Giacomelli,
A. Giaz,
A. Karadzhinova-Ferrer,
A. Loeschcke-Centeno,
A. Negri,
L. Pezzotti,
G. Polesello,
E. Proserpio,
A. Ribon,
R. Santoro,
I. Vivarelli
Abstract:
A prototype of a dual-readout calorimeter using brass capillary tubes surrounding scintillating and clear plastic optical fibres was tested using beams of particles with energies between 10 and 100 GeV produced by the CERN SPS. The scope of the test was to characterise the performance of the tube-based detector response to positrons in terms of linearity, energy resolution, and lateral granularity…
▽ More
A prototype of a dual-readout calorimeter using brass capillary tubes surrounding scintillating and clear plastic optical fibres was tested using beams of particles with energies between 10 and 100 GeV produced by the CERN SPS. The scope of the test was to characterise the performance of the tube-based detector response to positrons in terms of linearity, energy resolution, and lateral granularity. After calibrating the detector and processing the output signal to correct for the energy dependency on the particle impact point, the linearity of the measurement was found to be better than 1\%. The positron response was compared to that predicted by a Geant4-based simulation, finding good agreement both in terms of energy resolution and shower profile. The detector resolution was estimated to be well described by a stochastic term of 14.5\% with a negligible constant term.
△ Less
Submitted 18 September, 2023; v1 submitted 16 May, 2023;
originally announced May 2023.
-
On the characterisation of SiPMs from pulse-height spectra
Authors:
V. Chmill,
E. Garutti,
R. Klanner,
M. Nitschke,
J. Schwandt
Abstract:
Methods are developed, which use the pulse-height spectra of SiPMs measured in the dark and illuminated by pulsed light, to determine the pulse shape, the dark-count rate, the gain, the average number of photons initiating a Geiger discharge, the probabilities for prompt cross-talk and after-pulses, as well as the electronics noise and the gain fluctuations between and in pixels. The entire pulse-…
▽ More
Methods are developed, which use the pulse-height spectra of SiPMs measured in the dark and illuminated by pulsed light, to determine the pulse shape, the dark-count rate, the gain, the average number of photons initiating a Geiger discharge, the probabilities for prompt cross-talk and after-pulses, as well as the electronics noise and the gain fluctuations between and in pixels. The entire pulse-height spectra, including the background regions in-between the peaks corresponding to different number of Geiger discharges, are described by single functions. As a demonstration, the model is used to characterise a KETEK SiPM with 4382 pixels of 15 μm x 15 μm area for voltages between 2.5 and 8 V above the breakdown voltage at 20°C. The results are compared to other methods of characterising SiPMs. Finally, examples are given, how the complete description of the pulse-eight spectra can be used to optimise the operating voltage of SiPMs, and a method for an in-situ calibration and monitoring of SiPMs, suited for large-scale applications, is proposed.
△ Less
Submitted 21 February, 2017; v1 submitted 5 September, 2016;
originally announced September 2016.
-
Study of the breakdown voltage of SiPMs
Authors:
V. Chmill,
E. Garutti,
R. Klanner,
M. Nitschke,
J. Schwandt
Abstract:
The breakdown behaviour of SiPMs (Silicon PhotoMultiplier) with pixel sizes of 15$\times $15, 25$\times $25, 50$\times $50, and 100$\times $100 $μ$m$^2$, manufactured by KETEK, has been investigated. From the current-voltage characteristics measured with and without illumination by LED light of 470 nm wavelength, the current-breakdown voltage, $V_I$, and from linear fits of the voltage dependence…
▽ More
The breakdown behaviour of SiPMs (Silicon PhotoMultiplier) with pixel sizes of 15$\times $15, 25$\times $25, 50$\times $50, and 100$\times $100 $μ$m$^2$, manufactured by KETEK, has been investigated. From the current-voltage characteristics measured with and without illumination by LED light of 470 nm wavelength, the current-breakdown voltage, $V_I$, and from linear fits of the voltage dependence of the SiPM gain, measured by recording pulse-area spectra, the gain-breakdown voltage, $V_G$, have been obtained. The voltage dependence of the Geiger-breakdown probability was determined from the fraction of zero photoelectron events with LED illumination. By comparing the results to a model calculation, the photodetection-breakdown voltage, $V_{PD}$, has been determined. Within experimental uncertainties, $V_I$ and $V_{PD}$ are equal and independent of pixel size. For $V_G$, a dependence on pixel size is observed. The difference $V_I - V_G$ is about 1 V for the SiPM with 15 $μ$m pixels, decreases with pixel size and is compatible with zero for the SiPM with 100 $μ$m pixels.
△ Less
Submitted 4 May, 2016;
originally announced May 2016.
-
An Educational Kit Based on a Modular Silicon Photomultiplier System
Authors:
V. Arosio,
M. Caccia,
V. Chmill,
A. Ebolese,
A. Martemiyanov,
F. Risigo,
R. Santoro,
M. Locatelli,
M. Pieracci,
C. Tintori
Abstract:
Silicon Photo-Multipliers (SiPM) are state of the art light detectors with unprecedented single photon sensitivity and photon number resolving capability, representing a breakthrough in several fundamental and applied Science domains. An educational experiment based on a SiPM set-up is proposed in this article, guiding the student towards a comprehensive knowledge of this sensor technology while e…
▽ More
Silicon Photo-Multipliers (SiPM) are state of the art light detectors with unprecedented single photon sensitivity and photon number resolving capability, representing a breakthrough in several fundamental and applied Science domains. An educational experiment based on a SiPM set-up is proposed in this article, guiding the student towards a comprehensive knowledge of this sensor technology while experiencing the quantum nature of light and exploring the statistical properties of the light pulses emitted by a LED.
△ Less
Submitted 30 June, 2014; v1 submitted 16 August, 2013;
originally announced August 2013.
-
Photon-number statistics with Silicon photomultipliers
Authors:
Marco Ramilli,
Alessia Allevi,
Valery Chmill,
Maria Bondani,
Massimo Caccia,
Alessandra Andreoni
Abstract:
We present a description of the operation of a multi-pixel detector in the presence of non-negligible dark-count and cross-talk effects. We apply the model to devise self-consistent calibration strategies to be performed on the very light under investigation.
We present a description of the operation of a multi-pixel detector in the presence of non-negligible dark-count and cross-talk effects. We apply the model to devise self-consistent calibration strategies to be performed on the very light under investigation.
△ Less
Submitted 17 January, 2010; v1 submitted 25 October, 2009;
originally announced October 2009.